You are on page 1of 3

38 3 Vol . 38 , No .

3
2007 5 BO IL ER TEC HNOL O GY May. ,2007

: CN31 - 1508 ( 2007) 03 - 0043 - 03


, ,
( , 071003)

: ; ;
:

2 , ,
,

: T K229 . 6 : A

,
1
a
Rx = 100 % ( 1)

a+b

x
, , , R x ,
, , 1
; ,
1
, , ,
( )
,
( ) / (m)
, , [ 1 ,2 ] 6 1 000 R1
8 750 R750
12 500 R500

30 200 R200
, 40 150 R150
; 60 100 R100
70 90 R90
80 75 R75

2


, , ,
, ,
, ,
,
, 30 70 , R200 R90
,



, ag , 1 300 m , 20 60
, bg , m
:2006 - 07 - 12 ; :2006 - 09 - 22
: (1981 - ) , , ,

44 38

, , 2 R90 b R200
R90 b R200 / %
15 0. 021 1. 476
20 0. 018 2. 797
3 25 0. 015 4. 593
30 0. 013 6. 887
, 35 0. 012 9. 701
40 0. 010 13. 052
,
1 n = 1 , R90 = 20
,
R x =
f ( x ) ,
[ 3 ] ( Ro sin2Rammler ) ,
n
- bx
R x = 100e ( 2)
R90 R200 ,
1 100 1 100
b = n ln = n ln ( 3)
90 R90 x Rx
1 ln100 - ln R200
n = lg
200 ln100 - ln R90 1 R x = 100e - 0. 018 x
lg
90
4. 6 - ln R200 ( 5) , n = 1 , R90 = 20
= 2. 88lg ( 4)
4. 6 - ln R90 , 2
: R x x ,m
( ) , % ;
b ;
n ,

n , , n ,
,
n = 0 . 81 . 3 ,
2 y = f ( x) = - 55 . 92ln0. 01 x
4
, Mathematic
M PS y = f ( x) = - 55. 92ln0. 01 x
n , R90 , x = R90 [20 ,100]
( 3) b ( 2) : d = 33. 42 m ,
, ( 2) : R90
1

y = f ( x) = -
1
ln
x n
( 5) 3 6
b 100
: x
, % ;
y
( 5)
R x
n , n = 1 ,
R90 = 15 R90 = 20 R90 = 25 R90 = 30 R90 =
35 R90 = 40 (3)
3 b R 90
b R200 , 2
3 , : 45

3 , b R 90 ,
R90

6 d R 200

5
4 R200 R90
,
4 , R200 R90 ,

200 m R90
,
, ,

;
,

:
[ 1 ] , . [ M ] . :
,2004.
5 d R 90 [ 2 ] , . [ M ] . :
,2006.
5 , d R 90 [ 3 ] , . [ M ] . :
, R90 , ,1999.
6 , d R 200 [ 4 ] DL/ T5145 - 2002 ,
[ S] .
, R200 ,
[ 5 ] . Mat hematica [ M ] . :
, 2002.

The Me t hod of Cal c ul a t i ng t he Di a me t e r of Coal Dus t B a s e d


on t he S ol e Coal Fi ne ne s s s Sizi ng Da t a
WAN G Quan2gang , YAN Wei2ping , C H EN Yin2ying
( School of Energy & Power Engineering , Nort h China Elect ric Power University , Baoding 071003 , China)

Ke y w ords : boiler ; sieve number ; mean diameter of coal dust


Abs t ra c t : The nat ure of coal2fired boiler s coal is very important for t he efficiency of co m2
bustio n , so me element s of milling system and ext remely fo r t he operatio n of t he whole boiler
unit . This paper p resent s a met hod of calculating t he mean diameter of coal dust t hro ughing
t wo co mmo n screens in power plant , and gains t he relatio n bet ween t he mean diameter and
t he coal fineness. The result can give a met hod of gaining t he mean diameter exactly and
rapidly.