Professional Documents
Culture Documents
Unit Series AC
How to Order
AC 30 A F 03 DE KV 12R
Option
F.R.L. unit Symbol Description Applicable model
1 (11) 0.02 to 0.2 MPa setting AC10 to 60
Body size
2 Metal bowl AC10 to 60
10 20 25 30 40 50 55 60
3 Lubricator with drain cock AC10 to 60
6 Nylon bowl AC10 to 60
F.R.L.
8 Metal bowl with level gauge AC25 to 60
C With bowl guard AC25 to 60
AV
J (12) Drain guide 1/4 AC10 to 60
Model combination
N Non-relieving type AC10 to 60
Combination AU
Symbol Filter Mist R Flow direction: Right Left AC10 to 60
Air filter Regulator Lubricator regulator separator
Nil (1) (2) (3) W Drain cock with barb fitting:
6 x 4 nylon tubing
AC25 to 60 AF
A (2) (1)
(13)
B (1) (2) Z
Name plate, caution plate for bowl, and
pressure gauge in imperial units (PSI, F)
AC10 to 60 AR
C (1) (3) (2)
When more than one specification is required, indicate
D (1) (2) in ascending alphanumeric order.
IR
Note 1) The number inside ( ) indicates the Note 11) The only difference from the standard
combination order counted from the specifications is the adjusting spring for VEX
inlet side. the regulator. It does not restrict the
setting of 0.2 MPa or more.
Note 12) Without a valve function. AMR
Note 13) For thread types M5 and NPT.
This product is for overseas use only
Thread type according to the new Measurement Law.
ITV
(The SI unit type is provided for use in
Metric system thread (M5)
Nil Japan.) IC
Rc Pressure switch comes with a dual unit
N (2) NPT scale in SI (MPa) and imperial (PSI)
units. VBA
F (3) G Attachment
Note 2) Drain guide is NPT 1/4 (applicable to AC25 Port size for
to 60), and the exhaust port for auto-drain Symbol Description Attachment
mounting position
Applicable
model
intermediate
air release
VE
comes with 3/8" One-touch fitting Nil None
(applicable to AC25 to 60).
AF + AR + [K] + AL AC20 to 40 AC20: 1/8 VY1
Note 3) Drain guide is G 1/4 (applicable to AC25 to AC25: 1/4
60). K Check valve
AC30: 1/4
AW + [K] + AL AC20A to 40A AC40: 3/8 G
AF + AR + [S] + AL AC20 to 60
Port size
AW + [S] + AL AC20A to 40A PPA
Port Body size Pressure
Symbol size S AF + [S] + AR AC20B to 60B
switch
10 20 25 30 40 50 55 60
AF + AFM + [S] + AR AC20C to 40C AL
M5 M5
AW + [S] + AFM AC20D to 40D
01 1/8
AC10: M5 x 0.8
02 1/4 AF + [T] + AR + AL AC10 to 60AC20: 1/8
03 3/8 AC25: 1/4
T T-interface AC30: 1/4
04 AF + [T] + AR AC10B to 60B AC40: 3/8
1/2
AC50: 3/8
06 3/4
AF + AFM + [T] + AR AC20C to 40C AC55: 1/2
10 1 AC60: 1/2
AF + AR + AL + [V] AC20 to 50
AW + AL + [V] AC20A to 40A
Residual
V pressure relief AF + AR + [V] AC20B to 50B
3 port valve
Accessory AF + AFM + AR + [V] AC20C to 40C
Symbol Description Applicable model AW + AFM + [V] AC20D to 40D
Nil [V] + AF + ARK AC20B to 50B
Residual
C Float type auto-drain (N.C.) (4) AC10 to 60 V1 pressure relief [V] + AF + AFM + ARK AC20C to 40C
3 port valve
D Float type auto-drain (N.O.) (4) AC25 to 60 [V] + AWK + AFM AC20D to 40D
E With square embedded type pressure gauge (With limit indicator) AC20 to 60 Note 6) When more than one attachment is required, order in
With round pressure gauge (Without limit indicator)
alphabetical order.
(5) AC10
G Note 7) Piping adapter, pressure switch with piping adapter,
With round pressure gauge (With limit indicator) AC20 to 60 and cross interface need to be ordered separately.
Note 4) Applicable tubing O.D for auto-drain connection should be Note 8) Please contact SMC when using a pressure switch
3/8" in case NPT thread port is chosen. and T-interface together for ACB.
Note 5) Mounting thread for pressure gauge: Note 9) The bracket position varies depending on the T-
1/16 for AC10; 1/8 for AC20 to 30; 1/4 for AC40 to 60 interface or pressure switch mounting. Refer to the
Pressure gauge is not mounted and is supplied loose at the table on page 14-2-30 for standard bracket position.
time of shipment. Note 10) With this combination, regulators and filter regulators
will be with back flow function type.
For safety, check that the outlet pressure is exhausted
and is atmospheric pressure by pressure gauge.
14-2-9
Series AC
Accessory/Optional Specifications Combination
: Combination available : Combination not available : Varies depending on the model : Available only with NPT thread
F.R.L. unit applicable model
Symbol
Combination Accessory Optional specifications
Accessory/ AC10 AC20 AC20B AC25B AC30 AC30A AC30B AC30C AC30D
AC10B AC20C AC25 to to
Optional specifications C D E G 1 2 3 6 8 C J N R WZ AC10A AC20A AC20D AC25C AC60 AC40A AC60B AC40C AC40D
Nylon bowl -6
Metal bowl with level gauge -8
Attachment
Port size Function
M5 x 0.8 P. 14-2-24
T-interface 1/8, 1/4, 3/8, 1/2
Redirects the air flow.
Check valve 1/8, 1/4, 3/8 Prevents back flow from lubricator. P. 14-2-26
M5 x 0.8 P. 14-2-27
Cross interface 1/8, 1/4, 3/8, 1/2
Allows piping in all 4 directions.
Residual pressure relief 1/8, 1/4, 3/8, 1/2, 3/4, 1 Releases residual pressure in lines. P. 14-2-28
3 port valve
14-2-10
F.R.L. Unit Air Filter + Regulator + Lubricator
Series AC10 to 60
P. 14-2-31
JIS Symbol
Standard Specifications
Model AC10 AC20 AC25 AC30 AC40 AC40-06 AC50 AC55 AC60
Air filter AF10 AF20 AF30 AF30 AF40 AF40-06 AF50 AF60 AF60
Component Regulator AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR50 AR60
Lubricator AL10 AL20 AL30 AL30 AL40 AL40-06 AL50 AL60 AL60
1/8 1/4 1/4 1/4 3/4
Port size M5 x 0.8 3/8 3/4 1 1
1/4 3/8 3/8 1/2 1
(1)
Pressure gauge port size 1/16 1/8 1/8 1/8 1/4 1/4 1/4 1/4 1/4
Fluid Air
Proof pressure 1.5 MPa
Max. operating pressure 1.0 MPa
Set pressure range 0.05 to 0.7 MPa 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (2) (at relief flow rate of 0.1 l /min (ANR))
Ambient and 5 to 60C (With no freezing)
fluid temperature
Nominal filtration rating 5 m
Recommended lubricant Class 1 turbine oil (ISO VG32)
Bowl material Polycarbonate
Bowl guard Option Standard
Regulator construction Relieving type
Weight (kg) 0.27 0.73 0.91 1.00 1.74 1.95 4.17 4.25 4.34
Note 1) Pressure gauge connection threads are not required for F.R.L. unit with a square embedded type pressure gauge (AC20 to AC60).
Note 2) Not applicable to AC10.
Round type
1.0 MPa Square (2)
embedded type GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS
Accessory
(3)
Round type G-27-10-R1 G36-2-01 G36-2-01 G36-2-01 G46-2-02 G46-2-02 G46-2-02 G46-2-02 G46-2-02
0.2 MPa Square (2)
embedded type GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS
(4)
Float type N.O. AD38 AD38N (7) AD38 AD38N (7) AD48 AD48N (7) AD48 AD48N (7) AD48 AD48N (7) AD48 AD48N (7) AD48 AD48N (7)
auto-drain N.C. AD17 AD27 AD37 AD37N (7) AD37 AD37N ( 7) AD47 AD47N (7) AD47 AD47N (7) AD47 AD47N (7) AD47 AD47N (7) AD47 AD47N (7)
Spacer Y100 Y200 Y300 Y300 Y400 Y500 Y600 Y600 Y600
Check valve (5) (6) AKM2000-(0201) AKM3000-(0102) AKM3000-(0102) AKM4000-(0203)
Pressure switch (6) IS1000M-20 IS1000M-30 IS1000M-30 IS1000M-40 IS1000M-50 IS1000M-60 IS1000M-60 IS1000M-60
01 03
T-interface (5) Y110-M5 Y210- (02) Y310- (01) Y310-(01) Y410-(02) Y510-(02) Y610-(04) Y610-(03) Y610-(03)
Attachment
14-2-12
F.R.L. Unit Series AC10 to 60
Flow Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa
0.5 0.5
Operating pressure: 0.1 MPa or more.
0.4 0.4 <N.C. type> AR
0.3 0.3
Operating pressure for AD17, AD27:
0.1 MPa or more.
0.2 0.2
IR
Operating pressure for AD37, AD47:
0.15 MPa or more.
0.1 0.1
2. Use a regulator or filter regulator with a
VEX
0 0
0 200 400 600 800 0 2000 4000 6000 8000 10000 back flow mechanism when mounting a 3
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) port valve for residual pressure release on AMR
AC25 Rc 3/8 AC55 Rc 1 the IN side to ensure the release of the
0.6 0.6
residual pressure. Otherwise, residual ITV
pressure will not be fully released.
Outlet pressure (MPa)
0.5 0.5
Caution IC
0.4 0.4
1. When releasing air at the intermediate
0.3 0.3 position using a T-interface on the inlet side
VBA
0.2 of the lubricator, lubricant may back flow.
0.2
Therefore, releasing air that does not VE
0.1 0.1 contain traces of lubricant is not possible.
0 0
To release air that does not contain traces VY1
0 500 1000 1500 0 2000 4000 6000 8000 10000 of lubricant, use a check valve (Series
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) AKM) on the inlet side of the lubricator to
prevent a back flow of the lubricant.
G
AC30 Rc 3/8 AC60 Rc 1
2. Mounting a 3 port valve for residual
0.6 0.6
pressure release on the IN side of the PPA
Outlet pressure (MPa)
0.5
0.4
Mounting and Adjustment Air Supply
0.3 Caution Caution
0.2 1. A knob cover is available to prevent 1. Use an air filter with 5 m or less filtration
careless operation of the knob. Refer to rating on the inlet side of the valve to avoid
0.1 page 14-2-6 for details. any damage to the seat caused by dust
0
0 1000 2000 3000 Piping when mounting a 3 port valve for residual
Flow rate (l/min (ANR)) pressure release on the inlet side.
Warning
1. When mounting a check valve, make
sure the arrow (IN side) points in the
correct direction of air flow.
14-2-13
Series AC10 to 60
Conditions:
Inlet pressure 0.7 MPa
Outlet pressure 0.2 MPa
Pressure Characteristics (Representative values) Flow rate 20 l/min (ANR)
AC10 AC40-06
0.3
0.25
Outlet pressure (MPa)
0.2
0.15
0.15
0 0
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa) Inlet pressure (MPa)
AC20 AC50
0.25 0.25
Outlet pressure (MPa)
0.2 0.2
0.15 0.15
0 0
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa) Inlet pressure (MPa)
AC25 AC55
0.25 0.25
Outlet pressure (MPa)
0.2 0.2
0.15 0.15
0 0
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa) Inlet pressure (MPa)
AC30 AC60
0.25 0.25
Outlet pressure (MPa)
0.2 0.2
0.15 0.15
0 0
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa) Inlet pressure (MPa)
AC40
0.25
Outlet pressure (MPa)
Set point
0.2
0.15
0
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa)
14-2-14
F.R.L. Unit Series AC10 to 60
Dimensions
Pressure gauge port size
AC10/20 A P G
E F Q
L
H
IN OUT
H
L
J
OUT
Pressure gauge
B
(Option)
K Square embedded type M F.R.L.
pressure gauge
(Option)
AV
Drain
Port size N
Air filter Regulator Lubricator Min. clearance AU
D
for maintenance
AC25/30/40/50/55/60 Pressure gauge port size
A P G AF
E F Q
L
AR
H
C
IN OUT
IR
H
L
OUT
B Pressure gauge
VEX
(Option)
K M
Square embedded type
AMR
pressure gauge
(Option) ITV
Port size
Drain N IC
Min. clearance
D
Air filter Regulator Lubricator for maintenance
VBA
Applicable model AC10, AC20 AC25, AC30, AC40, AC40-06, AC50, AC55, AC60
With auto-drain (N.C.) Metal bowl With auto-drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting
VE
Optional VY1
B
B
B
B
B
specifications
B
N.O.: Black
G
B
O S N.C.: Gray O
S
M5 x 0.8 10 One-touch 1/4 Barb fitting
fitting Width across flats 17 Applicable tubing: T0604
PPA
(mm)
Standard specifications Accessory specifications
AL
Model Port size Bracket mounting size With pressure gauge With auto-drain
A B C D
E F G H J K L L M N P Q T B
AC10 M5 x 0.8 87 85 26 35 28 31 25 20 27 7 4.5 4.5 2.8 40 26 0 104
AC20 1/8, 1/4 126 123 36 60 41.5 43 30 24 33 12 5.5 5.5 3.2 50 65 29.5 2 (1) 141
AC25 1/4, 3/8 167 153 38 80 55 57 41 35 14 7 7 4 71 64 28.5 0 194
AC30 1/4, 3/8 167 153 38 80 55 57 41 35 14 7 7 4 71 66 30.5 3.5 194
AC40 1/4, 3/8, 1/2 220 187 40 110 72.5 75 50 40 18 9 9 4 88 74 35 3.5 226
AC40-06 3/4 235 187 38 110 77.5 80 50 40 18 9 9 4.6 88 74 35 3 226
AC50 3/4, 1 282 264 43 110 93 96 70 50 20 11 11 6.4 115 84 44.5 3.3 303
AC55 1 292 279 45 110 98 96 70 50 20 11 11 6.4 117.5 84 44.5 3.3 318
AC60 1 297 280 46 110 98 101 70 50 20 11 11 6.4 117.5 84 44.5 3.3 318
Optional specifications (2) Note 1) For AC20 only, the position of the pressure
gauge is above the center of the piping.
Model With barb fitting With drain guide Metal bowl Metal bowl with level gauge Note 2) For optional specifications (with barb fitting,
B B B B with drain guide, with metal bowl, or with level
AC10 gauge), the total length (dimension for B) will
85
vary.
AC20 123
AC25 161 160 166 186
AC30 161 160 166 186
AC40 195 194 200 220
AC40-06 195 194 200 220
AC50 272 271 276 296
AC55 287 286 292 312
AC60 288 287 293 313
14-2-15
F.R.L. Unit Series AC
Attachment Specifications
Piping Adapter (E): M5 x 0.8, 1/8, 1/4, 3/8, 1/2, 3/4, 1
A piping adapter allows installation/removal of the component Port size
without removing the piping and thus makes maintenance easier.
B
Center of
F.R.L. body
A D
(mm)
Model Note) Port size A B D Applicable model
E100-M5 M5 x 0.8 10 14 14 AC10, AW10, AF10, AR10, AL10
E200-01 1/8 AC20
E200-02 1/4 30 23.5 28 AF20, AR20, AW20
E200-03 3/8 AL20, AFM20, AFD20, AWM20, AWD20
Piping adapter E300-02 1/4 AC25, AC30
E300-03 3/8 32 30 30 AF30, AR30, AW30
E300-04 1/2 AL30, AFM30, AFD30, AWM30, AWD30
E400-02 1/4 AC40
E400-03 3/8 AF40, AR40, AW40
32 36 36 AL40, AFM40, AFD40
E400-04 1/2
AWM40, AWD40
E400-06 3/4
AC40-06, AF40-06, AR40-06, AW40-06
E500-06 3/4 32 40 44
AL40-06, AFM40-06, AFD40-06
E600-06 3/4 AC50, AC55, AC60, AC50B, AC55B, AC60B
35 48 53
E600-10 1 AF50, AR50, AL50, AF60, AR60, AL60
Note) in model numbers indicates a thread type. No indication is
necessary for Rc; however, indicate N for NPT, and F for G.
Separate interfaces are required for modular unit.
Factory mounting of a piping adapter on the AC models is available as a
special order.
T-interface
Center of
F.R.L. body
A D
(mm)
Model Port size A B C D E Applicable model
Y110-M5 M5 x 0.8 11 19 12 14 8 AC10, AC10B
Y210-01 1/8 AC20, AC20B
15 42 32 28 19
Y210-02 1/4 AC20C
Y310-01 1/8 AC25, AC25B
15 53 39 30 19 AC25C, AC30
Y310-02 1/4 AC30B, AC30C
Y410-02 1/4 AC40, AC40B
19 62 44 36 24
Y410-03 3/8 AC40C
Y510-02 1/4 AC40-06, AC40B-06
19 66 46 44 24
Y510-03 3/8 AC40C-06
Caution on Mounting AC50, AC55
Y610-03 3/8
If a T-interface is used on the IN side of the lubricator, lubricant 22 81 57 53 30
AC60, AC50B
Y610-04 1/2 AC55B, AC60B
may be mixed. Use the Series AKM check valve to avoid such
possibility. Note) in model numbers indicates a thread type. No indication is
necessary for Rc; however, indicate N for NPT, and F for G.
Separate interfaces are required for modular unit.
Refer to the attachment table on Front matter 2 for standard port sizes
when using with AC.
14-2-24
Attachment Specifications Series AC
Pressure Switch with Piping Adapter (P)
Approx. 500
Pressure switch with piping adapter
A D
E 23
JIS Symbol
C
AV
B
AU
Specifications
Fluid Air AF
Proof pressure 1.0 MPa Center of
F.R.L. body
Maximum operating pressure 0.7 MPa AR
Set pressure range (mm)
(When OFF) 0.1 to 0.4 MPa
Differential 0.08 MPa
Model (1) Port size A B C D E Applicable model IR
IS1000E-2001 1/8 AC20
Ambient and fluid temperature 5 to 60C (With no freezing)
IS1000E-2002 1/4 30 68 57 28 16 AR20, AW20 VEX
IS1000E-2003 3/8 AWM20, AWD20
Switch characteristics
Contact point configuration 1a
IS1000E-3002 1/4 AC25, AC30 AMR
IS1000E-3003 3/8 32 74.5 60.5 30 13 AR25, AR30, AW30
Maximum contact point capacity 2 VA(AC), 2 W(DC)
Operating voltage: AC, DC 100 V or less
IS1000E-3004 1/2 AWM30, AWD30 ITV
IS1000E-4002 1/4
12 V to 24 VAC, DC: 50 mA
Maximum operating current 48 VAC, DC: 40 mA IS1000E-4003 3/8
32 80.5 62.5 37 12.5
AC40 (2) IC
100 VAC, DC: 20 mA IS1000E-4004 1/2 AR40, AW40
AWM40, AWD40
IS1000E-4006 3/4 VBA
Note 1) in the model numbers indicates a thread type. No indication
is necessary for Rc; however, indicate N for NPT, and F for G.
Note 2) A pressure switch cannot be mounted on AC40-06 and VE
AW40-06.
Separate interfaces are required for modular unit. VY1
The pressure switch on AC40-06 and above and AW40-06 can
be mounted by screwing IS1000-01 into the piping adapter E500-
06-X501 or E600-06-X501 to E600-06 to 10-X501 (with top- G
face thread Rc 1/8). Products with a premounted switch are
available as a special order. Please contact SMC regarding their
availability.
PPA
How to Order AL
IS1000E 30 03
Option
Pressure switch X201 Lead wire length: 3 m
with piping X202 Regulating pressure range: 0.1 to 0.6 MPa
adapter X207 MPa/PSI Dual scale
Body size X215 Lead wire length: 3 m; Regulating pressure range: 0.1 to 0.6 MPa
30 For AC25, AC30 X251 Lead wire length: 3 m; Opposite-side mounting (Left-side mounting style)
Set pressure range: 0.1 to 0.6 MPa; Opposite-side mounting
40 For AC40-02 to 04 X252 (Left-side mounting style)
Lead wire length: 3 m; Regulating pressure range: 0.1 to 0.6 MPa;
Thread type X253
Opposite-side mounting (Left-side mounting style)
Nil Rc
This product is for overseas use only according to the new Measurement Law.
N NPT (The SI unit type is provided for use in Japan.)
F G
Piping adapter port size
Port Body size
Symbol
size 20 30 40
01 1/8
02 1/4
03 3/8
04 1/2
06 3/4
14-2-25
Series AC
Check Valve (K): Rc1/8, 1/4, 3/8
A check valve with intermediate air release port can be easily A
installed to prevent a back flow of lubricant when redirecting the
air flow and releasing the air on the outlet side of the regulator.
B
Check valve
C
IN OUT
Specifications
D
Model Effective area (mm2)
AKM2000 28
(mm)
AKM3000 55
Bypass
AKM4000 111 Model port size A B C D E Applicable model
Be sure to use above check valves
AKM2000 1/8, 1/4 40 40 28 11 11 AC20, AC20A
when redirecting the air flow on the
inlet side of the lubricator. Threads for AC25, AC25A
AKM3000 1/8, 1/4 53 48 34 14 13
IN and OUT ports are not machined. AC30, AC30A
AKM4000 1/4, 3/8 70 54 42 18 15 AC40, AC40A Note)
How to Order Note) Not applicable to AC40-06.
Refer to the attachment table on page 14-2-12 or 14-2-16 for standard
bypass port sizes applicable to AC.
AKM 30 00 01
Check valve
Bypass port size for
Body size redirecting air flow
20 30 40 Port Body size
Symbol
size 20 30 40
01 1/8
02 1/4
03 3/8
Thread type
Nil Rc
N NPT
F G
14-2-26
Attachment Specifications Series AC
Pressure Switch (S)
Approx. 500
A compact integrated pressure switch can be easily installed and
facilitates the pressure detection of the line.
15 23
Pressure switch
F.R.L.
C
B
JIS Symbol
AV
AU
Center of
F.R.L. body AF
A D
Specifications (mm) AR
Fluid Air Model A B C D Applicable model
Proof pressure 1.0 MPa IS1000M-20 11 76 66 28 AC20 IR
Maximum operating pressure 0.7 MPa IS1000M-30 13 86 72 30 AC25, AC30
Set pressure range (Off) 0.1 to 0.4 MPa IS1000M-40 15 95 77 36 AC40 VEX
Differential 0.08 MPa IS1000M-50 17 99 79 44 AC40-06
Ambient and fluid temperature 5 to 60C (With no freezing) IS1000M-60 22 92.5 68.5 53 AC50, AC55B, AC60 AMR
Note) Separate interfaces are required for modular unit.
ITV
Switch Characteristics How to Order
Contact point configuration 1a IC
Maximum contact point capacity
Operating voltage: AC, DC
2 VA(AC), 2 W(DC)
100 V or less
IS1000M 30 VBA
12 V to 24 VAC, DC : 50 mA
Pressure switch Accessory
Maximum operating current 48 VAC, DC : 40 mA X201 Lead wire length: 3 m VE
100 VAC, DC : 20 mA
Body size
Regulating pressure
20 For AC20 X202 range: 0.1 to 0.6 MPa
30 For AC25, AC30 VY1
X207 MPa/PSI dual scale
40 For AC40-02 to 04 Lead wire length: 3 m;
50 For AC40-06 X215 Regulating pressure
G
60 For AC50, AC55, AC60 range: 0.1 to 0.6 MPa
This product is for overseas use PPA
only according to the new
Measurement Law. (The SI unit
type is provided for use in Japan.)
AL
Cross Interface (C): M5 x 0.8, 1/8, 1/4, 3/8, 1/2
Center of
Pipings are possible in all 4 directions. F.R.L. body Port size
E
IN/OUT ports are not machined for threads. Please
contact SMC if threaded (machined) ports are required.
F
B
C
F E E
Cross interface
E: 4-Rc
A E
F: Without thread D
(mm)
Model Port size A B C D Applicable model
Y14-M5 M5 23 16 14 25 AC10
Y24-01 1/8
40 40 22 40 AC20
Y24-02 1/4
Y34-01 1/8
49 43 28 48 AC25, AC30
Y34-02 1/4
Y44-02 1/4
Caution on Mounting 60 48 36 54 AC40
Y44-03 3/8
When mounting a cross interface directly on the IN side of the Y54-03 3/8
lubricator, be sure to use a Series AKM check valve between the 72 62 40 62 AC40-06
Y54-04 1/2
lubricator and cross interface.
Note) in the model numbers indicates a thread type. No indication is
Factory mounting of a cross interface on the AC model is necessary for Rc; however, indicate N for NPT, and F for G.
available as a special order. If threaded ports are required, they are available as a special order.
Please contact SMC.
14-2-27
Series AC
Residual Pressure Relief 3 Port Valve (V)
With the use of a 3 port valve for residual pressure release,
0
pressure left in the line can be easily exhausted.
1
I
2-
3 port valve for
residual pressure release
G
H
F
E Lockable at the time of exhaust
JIS Symbol
(A) C
2
D
1 3
Specifications (P) (R)
Port size Effective area (mm2) ( ): Effective Area mm2 (Cv)
Model SUP
IN, OUT EXH IN to OUT OUT to EXH
1/8 10 (0.54) 11 (0.60)
A
VHS20 1/8
1/4 14 (0.76) 16 (0.87) IN OUT
1/4 16 (0.87) 14 (0.76)
VHS30 1/4
3/8 31 (1.68) 29 (1.57)
B
1/4 27 (1.46) 36 (1.95)
VHS40 3/8 3/8 38 (2.06) 40 (2.17)
1/2 55 (2.98) 42 (2.28) EXH
VHS40-06 3/4 1/2 77 (1.73) 49 (2.66)
3/4 82 (4.44) 50 (2.71)
VHS50 1/2 (mm)
1 125 (6.78) 53 (2.87)
Paint color (Standard) Handle: Red, Body: Platinum silver Model A B C D E F G H I
Use an air filter on the IN side for operating protection.
VHS20 59 20 40 34 45 33 28 45
How to Order VHS30 78 29 53 46 55 42 30 55
VHS40 107 39 70 63 22 58 44 36 63
VHS 30 F 03 RZ VHS40-06
VHS50
110
134
42
53
75
90
67
78
21
26
65
76
50
61
44
54
69
81
Residual pressure Caution
relief 3 port valve
1. Pleae consult with SMC when a pressure switch and T type
spacer are installed on the outlet of pressure release valve.
Body size 2. If a stop valve or a silencer is connected to the exhaust port of
Symbol Applicable model VHS20/30, the effective sectional area should be larger than
20 AC20 the figure indicated in the following table, to prevent
30 AC25/30 malfunction caused by back pressure. (This is not applicable to
40 AC40 VHS40 and VHS50)
50 AC50, AC60 Note) Model Effective area (mm2)
Note) When the valve is mounted VHS20 5
on AC60, the flow rate may 5
VHS30
decrease depending upon
the mounting position.
Thread type
Nil Rc
N NPT
Option
F G
Code Description
Port size R Flow direction: Right Left
Body size Note)
Z Name plate in imperial units (PSI, F)
Symbol Port size
20 30 40 50 Note) This product is for overseas use only
01 1/8 according to the new Measurement
Law. (The SI unit type is provided for
02 1/4 use in Japan.)
03 3/8
04 1/2
06 3/4
10 1
14-2-28
Spacers and Brackets Series AC
Accessory Dimensions
Spacer (X)
D
Center of
F.R.L. body
F.R.L.
C
1
X-X AV
B
RELEASE
X
2
Y200 Y400 AU
(mm)
X
Model A B C D Applicable model
AF
Seal
Y100 6 27 15 33 AC10, AC10A, AC10B
Y200 3 35.5 18.5 48 AC20 AR
Y300 4 47 26 59 AC25, AC30
Y400 5 57 31 65 AC40 A IR
Y500 5 61 33 70 AC40-06 Spacer width
Y600 6 75.5 41 86
AC50, AC55, AC60 VEX
AC50B, AC55B, AC60B
VY1
Center of
F.R.L. body
G
C
1
X-X PPA
EE (Y100T, Y200T only)
RELEASE
X
2
AL
E
X
G
Seal
Y200T Y400T
F J
A
H K
Spacer width
D
(mm)
Model A B BB C D E EE F G G H J K Applicable model
Y100T 6 56 24.5 40.5 20 27 6.8 4.5 4.5 14 2.8 25 AC10
Y200T 3 67 29 53 24 33 12 5.5 5.5 19 3.2 30 AC20
Y300T 4 82 41 68 35 14 7 7 21 4 41 AC25, AC30
Y400T 5 96 48 81.5 40 18 9 9 26 4 50 AC40
Y500T 5 96 48 86 40 18 9 9 27 4.6 50 AC40-06
Y600T 6 120 60 112 50 20 11 11 31 6.4 70 AC50, AC55, AC60, AC50B, AC55B, AC60B
Replacement Parts
Part no.
Description Material
Y100T Y200T Y300T Y400T Y500T Y600T
Seal HNBR (2) Y100P-060AS (1) Y200P-060S Y300P-060S Y400P-060S Y500P-060S Y600P-060S
Note 1) Y-100T comes with 2 O-rings.
Note 2) NBR seal is used for Y100T spacer because of no direct contact with fluid.
14-2-29
Series AC
Mounting Position for Spacer with Bracket
Bracket
Pressure switch: S Residual pressure
T-interface: T Check valve: K relief 3 port valve: V
SUP.
SUP
A
A
IN OUT IN OUT
A
A
Bracket
L1 L2 L3 L4 L1
(mm)
Attachment K S T V KS KT KV KST
Model L1 L2 L3 L1 L2 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L4 L1 L2 L3
AC10 28 48
AC20 41.5 43 43 41.5 43 41.5 61 41.5 43 43 41.5 43 57 41.5 61 43 41.5 43 43 43 41.5 61 57
AC25 55 57 57 55 57 55 76 55 57 57 55 57 74 55 76 57 55 57 57 57 55 76 74
AC30 55 57 57 55 57 55 76 55 57 57 55 57 74 55 76 57 55 57 57 57 55 76 74
AC40 72.5 75 75 72.5 75 72.5 99 72.5 75 75 72.5 75 95 72.5 99 75 72.5 75 75 75 72.5 99 95
AC40-06 77.5 80 77.5 104 77.5 80 80
AC50 93 96 93 124 93 96 96
AC55 98 96 98 124
AC60 98 101 98 129
Attachment KSV KTV KSTV ST SV STV TV
Model L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2 L3
AC10
AC20 41.5 43 57 43 41.5 61 43 43 41.5 61 57 43 41.5 61 41.5 43 57 41.5 61 57 41.5 61 43
AC25 55 57 74 57 55 76 57 57 55 76 74 57 55 76 55 57 74 55 76 74 55 76 57
AC30 55 57 74 57 55 76 57 57 55 76 74 57 55 76 55 57 74 55 76 74 55 76 57
AC40 72.5 75 95 75 72.5 99 75 75 72.5 99 95 75 72.5 99 72.5 75 95 72.5 99 95 72.5 99 75
AC40-06 77.5 104 77.5 80 102 77.5 104 102 77.5 104 80
AC50 93 124 93 96 124 93 124 124 93 124 96
AC55 98 124
AC60 98 129
Attachment
K S V KS KV KSV SV
Model L1 L2 L1 L1 L2 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2
AC20A 41.5 43 41.5 41.5 43 41.5 57 41.5 43 43 41.5 57 43 41.5 57
AC30A 55 57 55 55 57 55 74 55 57 57 55 74 57 55 74
AC40A 72.5 75 72.5 72.5 75 72.5 95 72.5 75 75 72.5 95 75 72.5 95
AC40A-06 77.5 77.5 80 77.5 102
Attachment
S T V SV TV
Model L1 L1 L1 L2 L1 L2 L1 L2
AC10B 28
AC20B 41.5 41.5 41.5 43 41.5 57 41.5 61
AC25B 55 55 55 57 55 74 55 76
AC30B 55 55 55 57 55 74 55 76
AC40B 72.5 72.5 72.5 75 72.5 95 72.5 99
AC40B-06 77.5 77.5 77.5 80 77.5 102 77.5 104
AC50B 93 93 93 96 93 124 93 124
AC55B 98 98
AC60B 98 98
Attachment
S T V SV TV
Model L1 L2 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2 L3
AC20C 41.5 43 41.5 43 41.5 43 43 41.5 43 57 41.5 43 61
AC25C 55 57 55 57 55 57 57 55 57 74 55 57 76
AC30C 55 57 55 57 55 57 57 55 57 74 55 57 76
AC40C 72.5 75 72.5 75 72.5 75 75 72.5 75 95 72.5 75 99
AC40C-06 77.5 80 77.5 80 77.5 80 80 77.5 80 102 77.5 80 104
Attachment
S V SV L1: Dimensions from the end of the IN side to the center of the mounting hole for the first bracket.
Model L1 L1 L2 L1 L2 L2: Mounting hole pitch between the first and the second bracket.
AC20D 41.5 41.5 43 41.5 57 L3: Mounting hole pitch between the second and the third bracket.
AC30D 55 55 57 55 74 L4: Mounting hole pitch between the third and the fourth bracket.
AC40D 72.5 72.5 75 72.5 95 Refer to dimensions pages for dimension A from the center of the piping and the mounting hole.
AC40D-06 77.5 77.5 80 77.5 102
14-2-30
F.R.L. Unit Series AC20 to 60
Made to Order Specifications:
Please contact SMC for detailed dimensions, specifications, and lead times.
F.R.L.
AV
AU
AF
AR
IR
Specifications VEX
Part no. -X465
Model ISE30---L AMR
Set pressure range 0.1 to 1 MPa
Pressure
Set/Display resolution 0.001 MPa ITV
switch
Power supply voltage 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With reverse connection protection)
Current consumption 45 mA or less (70 mA or less during current output)
IC
Pressure gauge port size: Rc 1/8
VBA
Applicable Model VE
Model AC20 AC25 AC30 AC40 AC40-06 AC50 AC55 AC60
14-2-31
Series AC
How to Order
AC 30 A F 03 D KV 12R X465 A
Switch specifications
F.R.L. unit
Symbol Output specifications
Body size A NPN output
20 25 30 40 50 55 60 B PNP output
C 1 to 5 V output
Model combination D 4 to 20 mA output
Combination With digital pressure switch
Symbol Filter Mist
Air filter Regulator Lubricator Regulator Separator (Series ISE30) (12)
Nil (1) (2) (3) Note 12) Digital pressure switch is not
A (2) (1) mounted and is supplied
loose at the time of
B (1) (2) Description shipment.
C (1) (3) (2) Symbol Description Applicable model
D (1) (2) 1 (9) 0.02 to 0.2 MPa setting AC20 to 60
Note 1) The circled numbers indicate the 2 Metal bowl AC20 to 60
order in which the units are
assembled. 3 Lubricator with drain cock AC20 to 60
6 Nylon bowl (Including sight dome) AC20 to 60
Thread type
8 Metal bowl with level gauge AC25 to 60
Nil Rc C With bowl guard AC20
N (2) NPT J (10) Drain guide 1/4 AC25 to 60
F (3) G N Non-relieving type AC20 to 60
Note 2) Drain guide is NPT 1/4 (applicable R Flow direction: Right Left AC20 to 60
to AC25 to 60), and the exhaust
port for auto-drain comes with 3/8" Drain cock with barb fitting:
W AC25 to 60
One-touch fitting (applicable to 6 x 4 nylon tubing
AC25 to 60).
Name plate and caution plate for
Note 3) Drain guide is G 1/4 (applicable to Z (11) bowl in imperial units (PSI, F) AC20 to 60
AC25 to 60).
Port size When more than one specification is required, indicate
Port Body size in ascending alphanumeric order.
Symbol
size 20 25 30 40 50 55 60 Note 9) The only difference from the standard
01 1/8 specifications is the adjusting spring for
the regulator. It does not restrict the
02 1/4
setting of 0.2 MPa or more.
03 3/8 Note 10) Without a valve function.
04 1/2 Note 11) For thread type NPT.
06 3/4 This product is for overseas use only
10 1 according to the new Measurement Law.
(The SI unit type is provided for use in
Japan.)
Accessory Attachment
Symbol Description Applicable model Attachment Port size for
Symbol Description Applicable model intermediate
Nil mounting position air release
C With float type auto-drain (N.C.) (4) AC20 to 60 Nil None
D With float type auto-drain (N.O.) (4) AC25 to 60 AF + AR + [K] + AL AC20: 1/8
AC20 to 40
K Check valve AC25: 1/4
Note 4) Applicable tubing O.D for auto drain connection should be AW + [K] + AL AC20A to 40A AC30: 1/4
AC40: 3/8
3/8" in case NPT thread port is chosen.
AC20: 1/8
AF + [T] + AR + AL AC20 to 60 AC25: 1/4
AC30: 1/4
T T-interface AF + [T] + AR AC20B to 60B AC40: 3/8
AC50: 3/8
AF + AFM + [T] + AR AC20C to 40C AC55: 1/2
AC60: 1/2
AF + AR + AL + [V] AC20 to 50
Note 13) Please consult with SMC for detailed AW + AL + [V] AC20A to 40A
dimensions and available attachments and Residual
V pressure relief
AF + AR + [V] AC20B to 50B
options.
Note 14) Refer to SMC catalog CAT.ES100-42 for 3 port valve AF + AFM + AR + [V] AC20C to 40C
detailed specifications and instructions of AW + AFM + [V] AC20D to 40D
digital pressure switch. [V] + AF + ARK AC20B to 50B
Residual
V1 (8) pressure relief [V] + AF + AFM + ARK AC20C to 40C
3 port valve
[V] + AWK+ AFM AC20D to 40D
Note 5) When more than one attachment is required, order in alphabetical order.
Note 6) Piping adapter, pressure switch with piping adapter, and cross interface need to be
ordered separately.
Note 7) The bracket position varies depending on the T-interface mounting.
Refer to the table on page 14-2-30 for standard bracket position.
Note 8) With this combination, requlators and filter requlators will be With back flow function type.
For safety, check that the ezhausted and is atmospheric pressure by pressure gauge.
14-2-32
F.R.L. Unit Series AC
How to Order
AC 30 A F 03 DE KV 12R
Option
F.R.L. unit Symbol Description Applicable model
1 (11) 0.02 to 0.2 MPa setting AC10 to 60
Body size
2 Metal bowl AC10 to 60
10 20 25 30 40 50 55 60
3 Lubricator with drain cock AC10 to 60
6 Nylon bowl AC10 to 60
F.R.L.
8 Metal bowl with level gauge AC25 to 60
C With bowl guard AC25 to 60
AV
J (12) Drain guide 1/4 AC10 to 60
Model combination
N Non-relieving type AC10 to 60
Combination AU
Symbol Filter Mist R Flow direction: Right Left AC10 to 60
Air filter Regulator Lubricator regulator separator
Nil (1) (2) (3) W Drain cock with barb fitting:
6 x 4 nylon tubing
AC25 to 60 AF
A (2) (1)
(13)
B (1) (2) Z
Name plate, caution plate for bowl, and
pressure gauge in imperial units (PSI, F)
AC10 to 60 AR
C (1) (3) (2)
When more than one specification is required, indicate
D (1) (2) in ascending alphanumeric order.
IR
Note 1) The number inside ( ) indicates the Note 11) The only difference from the standard
combination order counted from the specifications is the adjusting spring for VEX
inlet side. the regulator. It does not restrict the
setting of 0.2 MPa or more.
Note 12) Without a valve function. AMR
Note 13) For thread types M5 and NPT.
This product is for overseas use only
Thread type according to the new Measurement Law.
ITV
(The SI unit type is provided for use in
Metric system thread (M5)
Nil Japan.) IC
Rc Pressure switch comes with a dual unit
N (2) NPT scale in SI (MPa) and imperial (PSI)
units. VBA
F (3) G Attachment
Note 2) Drain guide is NPT 1/4 (applicable to AC25 Port size for
to 60), and the exhaust port for auto-drain Symbol Description Attachment
mounting position
Applicable
model
intermediate
air release
VE
comes with 3/8" One-touch fitting Nil None
(applicable to AC25 to 60).
AF + AR + [K] + AL AC20 to 40 AC20: 1/8 VY1
Note 3) Drain guide is G 1/4 (applicable to AC25 to AC25: 1/4
60). K Check valve
AC30: 1/4
AW + [K] + AL AC20A to 40A AC40: 3/8 G
AF + AR + [S] + AL AC20 to 60
Port size
AW + [S] + AL AC20A to 40A PPA
Port Body size Pressure
Symbol size S AF + [S] + AR AC20B to 60B
switch
10 20 25 30 40 50 55 60
AF + AFM + [S] + AR AC20C to 40C AL
M5 M5
AW + [S] + AFM AC20D to 40D
01 1/8
AC10: M5 x 0.8
02 1/4 AF + [T] + AR + AL AC10 to 60AC20: 1/8
03 3/8 AC25: 1/4
T T-interface AC30: 1/4
04 AF + [T] + AR AC10B to 60B AC40: 3/8
1/2
AC50: 3/8
06 3/4
AF + AFM + [T] + AR AC20C to 40C AC55: 1/2
10 1 AC60: 1/2
AF + AR + AL + [V] AC20 to 50
AW + AL + [V] AC20A to 40A
Residual
V pressure relief AF + AR + [V] AC20B to 50B
3 port valve
Accessory AF + AFM + AR + [V] AC20C to 40C
Symbol Description Applicable model AW + AFM + [V] AC20D to 40D
Nil [V] + AF + ARK AC20B to 50B
Residual
C Float type auto-drain (N.C.) (4) AC10 to 60 V1 pressure relief [V] + AF + AFM + ARK AC20C to 40C
3 port valve
D Float type auto-drain (N.O.) (4) AC25 to 60 [V] + AWK + AFM AC20D to 40D
E With square embedded type pressure gauge (With limit indicator) AC20 to 60 Note 6) When more than one attachment is required, order in
With round pressure gauge (Without limit indicator)
alphabetical order.
(5) AC10
G Note 7) Piping adapter, pressure switch with piping adapter,
With round pressure gauge (With limit indicator) AC20 to 60 and cross interface need to be ordered separately.
Note 4) Applicable tubing O.D for auto-drain connection should be Note 8) Please contact SMC when using a pressure switch
3/8" in case NPT thread port is chosen. and T-interface together for ACB.
Note 5) Mounting thread for pressure gauge: Note 9) The bracket position varies depending on the T-
1/16 for AC10; 1/8 for AC20 to 30; 1/4 for AC40 to 60 interface or pressure switch mounting. Refer to the
Pressure gauge is not mounted and is supplied loose at the table on page 14-2-30 for standard bracket position.
time of shipment. Note 10) With this combination, regulators and filter regulators
will be with back flow function type.
For safety, check that the outlet pressure is exhausted
and is atmospheric pressure by pressure gauge.
14-2-9
Series AC
Accessory/Optional Specifications Combination
: Combination available : Combination not available : Varies depending on the model : Available only with NPT thread
F.R.L. unit applicable model
Symbol
Combination Accessory Optional specifications
Accessory/ AC10 AC20 AC20B AC25B AC30 AC30A AC30B AC30C AC30D
AC10B AC20C AC25 to to
Optional specifications C D E G 1 2 3 6 8 C J N R WZ AC10A AC20A AC20D AC25C AC60 AC40A AC60B AC40C AC40D
Nylon bowl -6
Metal bowl with level gauge -8
Attachment
Port size Function
M5 x 0.8 P. 14-2-24
T-interface 1/8, 1/4, 3/8, 1/2
Redirects the air flow.
Check valve 1/8, 1/4, 3/8 Prevents back flow from lubricator. P. 14-2-26
M5 x 0.8 P. 14-2-27
Cross interface 1/8, 1/4, 3/8, 1/2
Allows piping in all 4 directions.
Residual pressure relief 1/8, 1/4, 3/8, 1/2, 3/4, 1 Releases residual pressure in lines. P. 14-2-28
3 port valve
14-2-10
F.R.L. Unit Filter Regulator + Lubricator
JIS Symbol
Pressure
Square embedded type GC3-10AS GC3-10AS GC3-10AS GC3-10AS
Accessory
(3)
gauge Round type G27-10-R1 G36-2-01 G36-2-01 G46-2-02 G46-2-02
0.2 MPa (2)
Square embedded type GC3-2AS GC3-2AS GC3-2AS GC3-2AS
(4) N.O. AD38 AD38N (7) AD48 AD48N (7) AD48 AD48N (7)
Float type auto-drain
N.C. AD17 AD27 AD37 AD37N (7) AD47 AD47N (7) AD47 AD47N (7)
Spacer Y100 Y200 Y300 Y400 Y500
(5) 01
Check valve (6) AKM2000- (02) AKM3000- (01)
02 AKM4000- (02)
03
(6)
Pressure switch IS1000M-20 IS1000M-30 IS1000M-40 IS1000M-50
(5) 01 (01) (02)
T-interface Y110-M5 Y210- Y310- Y410- Y510- (02)
Attachment
(6) 02
Residual pressure relief 3 port valve VHS20- 01
02 VHS30- 02
03 VHS40- 03
04
VHS40-06
01 02 02
(6) 03
Piping adapter E100-M5 E200- 02
03
E300- 03
04
E400- 04 E500-06
06
(6) 02 02
01
Pressure switch with piping adapter IS1000E-20 02 IS1000E-30 03
04
IS1000E-40 03
04
03 06
Note 1) in part numbers for a round pressure gauge indicates a type of connection thread. No indication is necessary for R; however, indicate N
for NPT.
Please contact SMC regarding the connection thread NPT and pressure gauge supply for PSI unit specifications.
Note 2) Includes one O-ring and 2 mounting screws.
Note 3) For 1.0 MPa.
Note 4) Minimum operating pressure: N.O. type0.1 MPa (AD17/27); N.C. type0.15 MPa (AD37/47).
Note 5) For F.R.L. units, port sizes not in ( ) are for standard application.
Note 6) Separate interfaces are required for modular unit.
Note 7) When N is specified in the end of part number of auto-drain, applicable tubing O.D should be 3/8".
14-2-16
F.R.L. Unit Series AC10A to 40A
Dimensions
AC10A/20A
A N F
E P
G
IN OUT
Q
F.R.L.
B
G
K
Pressure gauge
H
OUT
(Option)
Pressure gauge port size
J
Square embedded type AV
pressure gauge L
(Option)
Port size
AU
Lubricator
Drain Min. clearance M AF
Filter regulator for maintenance
D
AR
AC30A/40A A N F
E P IR
VEX
K
C
AMR
G
IN OUT
Q
ITV
B
G
K
Filter regulator
G
Applicable model AC10A, AC20A AC30A, AC40A, AC40A-06
With auto-drain (N.C.) Metal bowl With auto-drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting PPA
AL
Optional
B
B
B
specifications
B
N.O.: Black
B
O S N.C.: Gray O
S
M5 x 0.8 10 One-touch 1/4 Barb fitting
fitting Width across flats 17 Applicable tubing: T0604
(mm)
Standard specifications Accessory specifications
Model Port size Bracket mounting size With pressure gauge With auto-drain
A B C D
E F G H J K K L M N P Q B
AC10A M5 x 0.8 56 108 48 35 28 25 20 27 7 4.5 4.5 2.8 40 26 0 126
AC20A 1/8, 1/4 83 160 73 60 41.5 30 24 33 12 5.5 5.5 3.2 50 63 27 5 177
AC30A 1/4, 3/8 110 201 86 80 55 41 35 14 7 7 4 71 66 30.5 3.5 242
AC40A 1/4, 3/8, 1/2 145 239 92 110 72.5 50 40 18 9 9 4 88 76 38.5 1.5 278
AC40A-06 3/4 155 242 93 110 77.5 50 40 18 9 9 4.6 88 76 38.5 1.2 278
Optional specifications Note) Note) For optional specifications (with barb fitting, with drain
guide, with metal bowl, or with level gauge), the total
Model With barb fitting With drain guide Metal bowl Metal bowl with level gauge length (dimension for B) will vary.
B B B B
AC10A 107
AC20A 160
AC30A 209 208 214 234
AC40A 247 246 251 272
AC40A-06 250 249 255 275
14-2-17
F.R.L. Unit Series AC
Attachment Specifications
Piping Adapter (E): M5 x 0.8, 1/8, 1/4, 3/8, 1/2, 3/4, 1
A piping adapter allows installation/removal of the component Port size
without removing the piping and thus makes maintenance easier.
B
Center of
F.R.L. body
A D
(mm)
Model Note) Port size A B D Applicable model
E100-M5 M5 x 0.8 10 14 14 AC10, AW10, AF10, AR10, AL10
E200-01 1/8 AC20
E200-02 1/4 30 23.5 28 AF20, AR20, AW20
E200-03 3/8 AL20, AFM20, AFD20, AWM20, AWD20
Piping adapter E300-02 1/4 AC25, AC30
E300-03 3/8 32 30 30 AF30, AR30, AW30
E300-04 1/2 AL30, AFM30, AFD30, AWM30, AWD30
E400-02 1/4 AC40
E400-03 3/8 AF40, AR40, AW40
32 36 36 AL40, AFM40, AFD40
E400-04 1/2
AWM40, AWD40
E400-06 3/4
AC40-06, AF40-06, AR40-06, AW40-06
E500-06 3/4 32 40 44
AL40-06, AFM40-06, AFD40-06
E600-06 3/4 AC50, AC55, AC60, AC50B, AC55B, AC60B
35 48 53
E600-10 1 AF50, AR50, AL50, AF60, AR60, AL60
Note) in model numbers indicates a thread type. No indication is
necessary for Rc; however, indicate N for NPT, and F for G.
Separate interfaces are required for modular unit.
Factory mounting of a piping adapter on the AC models is available as a
special order.
T-interface
Center of
F.R.L. body
A D
(mm)
Model Port size A B C D E Applicable model
Y110-M5 M5 x 0.8 11 19 12 14 8 AC10, AC10B
Y210-01 1/8 AC20, AC20B
15 42 32 28 19
Y210-02 1/4 AC20C
Y310-01 1/8 AC25, AC25B
15 53 39 30 19 AC25C, AC30
Y310-02 1/4 AC30B, AC30C
Y410-02 1/4 AC40, AC40B
19 62 44 36 24
Y410-03 3/8 AC40C
Y510-02 1/4 AC40-06, AC40B-06
19 66 46 44 24
Y510-03 3/8 AC40C-06
Caution on Mounting AC50, AC55
Y610-03 3/8
If a T-interface is used on the IN side of the lubricator, lubricant 22 81 57 53 30
AC60, AC50B
Y610-04 1/2 AC55B, AC60B
may be mixed. Use the Series AKM check valve to avoid such
possibility. Note) in model numbers indicates a thread type. No indication is
necessary for Rc; however, indicate N for NPT, and F for G.
Separate interfaces are required for modular unit.
Refer to the attachment table on Front matter 2 for standard port sizes
when using with AC.
14-2-24
Attachment Specifications Series AC
Pressure Switch with Piping Adapter (P)
Approx. 500
Pressure switch with piping adapter
A D
E 23
JIS Symbol
C
AV
B
AU
Specifications
Fluid Air AF
Proof pressure 1.0 MPa Center of
F.R.L. body
Maximum operating pressure 0.7 MPa AR
Set pressure range (mm)
(When OFF) 0.1 to 0.4 MPa
Differential 0.08 MPa
Model (1) Port size A B C D E Applicable model IR
IS1000E-2001 1/8 AC20
Ambient and fluid temperature 5 to 60C (With no freezing)
IS1000E-2002 1/4 30 68 57 28 16 AR20, AW20 VEX
IS1000E-2003 3/8 AWM20, AWD20
Switch characteristics
Contact point configuration 1a
IS1000E-3002 1/4 AC25, AC30 AMR
IS1000E-3003 3/8 32 74.5 60.5 30 13 AR25, AR30, AW30
Maximum contact point capacity 2 VA(AC), 2 W(DC)
Operating voltage: AC, DC 100 V or less
IS1000E-3004 1/2 AWM30, AWD30 ITV
IS1000E-4002 1/4
12 V to 24 VAC, DC: 50 mA
Maximum operating current 48 VAC, DC: 40 mA IS1000E-4003 3/8
32 80.5 62.5 37 12.5
AC40 (2) IC
100 VAC, DC: 20 mA IS1000E-4004 1/2 AR40, AW40
AWM40, AWD40
IS1000E-4006 3/4 VBA
Note 1) in the model numbers indicates a thread type. No indication
is necessary for Rc; however, indicate N for NPT, and F for G.
Note 2) A pressure switch cannot be mounted on AC40-06 and VE
AW40-06.
Separate interfaces are required for modular unit. VY1
The pressure switch on AC40-06 and above and AW40-06 can
be mounted by screwing IS1000-01 into the piping adapter E500-
06-X501 or E600-06-X501 to E600-06 to 10-X501 (with top- G
face thread Rc 1/8). Products with a premounted switch are
available as a special order. Please contact SMC regarding their
availability.
PPA
How to Order AL
IS1000E 30 03
Option
Pressure switch X201 Lead wire length: 3 m
with piping X202 Regulating pressure range: 0.1 to 0.6 MPa
adapter X207 MPa/PSI Dual scale
Body size X215 Lead wire length: 3 m; Regulating pressure range: 0.1 to 0.6 MPa
30 For AC25, AC30 X251 Lead wire length: 3 m; Opposite-side mounting (Left-side mounting style)
Set pressure range: 0.1 to 0.6 MPa; Opposite-side mounting
40 For AC40-02 to 04 X252 (Left-side mounting style)
Lead wire length: 3 m; Regulating pressure range: 0.1 to 0.6 MPa;
Thread type X253
Opposite-side mounting (Left-side mounting style)
Nil Rc
This product is for overseas use only according to the new Measurement Law.
N NPT (The SI unit type is provided for use in Japan.)
F G
Piping adapter port size
Port Body size
Symbol
size 20 30 40
01 1/8
02 1/4
03 3/8
04 1/2
06 3/4
14-2-25
Series AC
Check Valve (K): Rc1/8, 1/4, 3/8
A check valve with intermediate air release port can be easily A
installed to prevent a back flow of lubricant when redirecting the
air flow and releasing the air on the outlet side of the regulator.
B
Check valve
C
IN OUT
Specifications
D
Model Effective area (mm2)
AKM2000 28
(mm)
AKM3000 55
Bypass
AKM4000 111 Model port size A B C D E Applicable model
Be sure to use above check valves
AKM2000 1/8, 1/4 40 40 28 11 11 AC20, AC20A
when redirecting the air flow on the
inlet side of the lubricator. Threads for AC25, AC25A
AKM3000 1/8, 1/4 53 48 34 14 13
IN and OUT ports are not machined. AC30, AC30A
AKM4000 1/4, 3/8 70 54 42 18 15 AC40, AC40A Note)
How to Order Note) Not applicable to AC40-06.
Refer to the attachment table on page 14-2-12 or 14-2-16 for standard
bypass port sizes applicable to AC.
AKM 30 00 01
Check valve
Bypass port size for
Body size redirecting air flow
20 30 40 Port Body size
Symbol
size 20 30 40
01 1/8
02 1/4
03 3/8
Thread type
Nil Rc
N NPT
F G
14-2-26
Attachment Specifications Series AC
Pressure Switch (S)
Approx. 500
A compact integrated pressure switch can be easily installed and
facilitates the pressure detection of the line.
15 23
Pressure switch
F.R.L.
C
B
JIS Symbol
AV
AU
Center of
F.R.L. body AF
A D
Specifications (mm) AR
Fluid Air Model A B C D Applicable model
Proof pressure 1.0 MPa IS1000M-20 11 76 66 28 AC20 IR
Maximum operating pressure 0.7 MPa IS1000M-30 13 86 72 30 AC25, AC30
Set pressure range (Off) 0.1 to 0.4 MPa IS1000M-40 15 95 77 36 AC40 VEX
Differential 0.08 MPa IS1000M-50 17 99 79 44 AC40-06
Ambient and fluid temperature 5 to 60C (With no freezing) IS1000M-60 22 92.5 68.5 53 AC50, AC55B, AC60 AMR
Note) Separate interfaces are required for modular unit.
ITV
Switch Characteristics How to Order
Contact point configuration 1a IC
Maximum contact point capacity
Operating voltage: AC, DC
2 VA(AC), 2 W(DC)
100 V or less
IS1000M 30 VBA
12 V to 24 VAC, DC : 50 mA
Pressure switch Accessory
Maximum operating current 48 VAC, DC : 40 mA X201 Lead wire length: 3 m VE
100 VAC, DC : 20 mA
Body size
Regulating pressure
20 For AC20 X202 range: 0.1 to 0.6 MPa
30 For AC25, AC30 VY1
X207 MPa/PSI dual scale
40 For AC40-02 to 04 Lead wire length: 3 m;
50 For AC40-06 X215 Regulating pressure
G
60 For AC50, AC55, AC60 range: 0.1 to 0.6 MPa
This product is for overseas use PPA
only according to the new
Measurement Law. (The SI unit
type is provided for use in Japan.)
AL
Cross Interface (C): M5 x 0.8, 1/8, 1/4, 3/8, 1/2
Center of
Pipings are possible in all 4 directions. F.R.L. body Port size
E
IN/OUT ports are not machined for threads. Please
contact SMC if threaded (machined) ports are required.
F
B
C
F E E
Cross interface
E: 4-Rc
A E
F: Without thread D
(mm)
Model Port size A B C D Applicable model
Y14-M5 M5 23 16 14 25 AC10
Y24-01 1/8
40 40 22 40 AC20
Y24-02 1/4
Y34-01 1/8
49 43 28 48 AC25, AC30
Y34-02 1/4
Y44-02 1/4
Caution on Mounting 60 48 36 54 AC40
Y44-03 3/8
When mounting a cross interface directly on the IN side of the Y54-03 3/8
lubricator, be sure to use a Series AKM check valve between the 72 62 40 62 AC40-06
Y54-04 1/2
lubricator and cross interface.
Note) in the model numbers indicates a thread type. No indication is
Factory mounting of a cross interface on the AC model is necessary for Rc; however, indicate N for NPT, and F for G.
available as a special order. If threaded ports are required, they are available as a special order.
Please contact SMC.
14-2-27
Spacers and Brackets Series AC
Accessory Dimensions
Spacer (X)
D
Center of
F.R.L. body
F.R.L.
C
1
X-X AV
B
RELEASE
X
2
Y200 Y400 AU
(mm)
X
Model A B C D Applicable model
AF
Seal
Y100 6 27 15 33 AC10, AC10A, AC10B
Y200 3 35.5 18.5 48 AC20 AR
Y300 4 47 26 59 AC25, AC30
Y400 5 57 31 65 AC40 A IR
Y500 5 61 33 70 AC40-06 Spacer width
Y600 6 75.5 41 86
AC50, AC55, AC60 VEX
AC50B, AC55B, AC60B
VY1
Center of
F.R.L. body
G
C
1
X-X PPA
EE (Y100T, Y200T only)
RELEASE
X
2
AL
E
X
G
Seal
Y200T Y400T
F J
A
H K
Spacer width
D
(mm)
Model A B BB C D E EE F G G H J K Applicable model
Y100T 6 56 24.5 40.5 20 27 6.8 4.5 4.5 14 2.8 25 AC10
Y200T 3 67 29 53 24 33 12 5.5 5.5 19 3.2 30 AC20
Y300T 4 82 41 68 35 14 7 7 21 4 41 AC25, AC30
Y400T 5 96 48 81.5 40 18 9 9 26 4 50 AC40
Y500T 5 96 48 86 40 18 9 9 27 4.6 50 AC40-06
Y600T 6 120 60 112 50 20 11 11 31 6.4 70 AC50, AC55, AC60, AC50B, AC55B, AC60B
Replacement Parts
Part no.
Description Material
Y100T Y200T Y300T Y400T Y500T Y600T
Seal HNBR (2) Y100P-060AS (1) Y200P-060S Y300P-060S Y400P-060S Y500P-060S Y600P-060S
Note 1) Y-100T comes with 2 O-rings.
Note 2) NBR seal is used for Y100T spacer because of no direct contact with fluid.
14-2-29
Series AC
Mounting Position for Spacer with Bracket
Bracket
Pressure switch: S Residual pressure
T-interface: T Check valve: K relief 3 port valve: V
SUP.
SUP
A
A
IN OUT IN OUT
A
A
Bracket
L1 L2 L3 L4 L1
(mm)
Attachment K S T V KS KT KV KST
Model L1 L2 L3 L1 L2 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L4 L1 L2 L3
AC10 28 48
AC20 41.5 43 43 41.5 43 41.5 61 41.5 43 43 41.5 43 57 41.5 61 43 41.5 43 43 43 41.5 61 57
AC25 55 57 57 55 57 55 76 55 57 57 55 57 74 55 76 57 55 57 57 57 55 76 74
AC30 55 57 57 55 57 55 76 55 57 57 55 57 74 55 76 57 55 57 57 57 55 76 74
AC40 72.5 75 75 72.5 75 72.5 99 72.5 75 75 72.5 75 95 72.5 99 75 72.5 75 75 75 72.5 99 95
AC40-06 77.5 80 77.5 104 77.5 80 80
AC50 93 96 93 124 93 96 96
AC55 98 96 98 124
AC60 98 101 98 129
Attachment KSV KTV KSTV ST SV STV TV
Model L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2 L3
AC10
AC20 41.5 43 57 43 41.5 61 43 43 41.5 61 57 43 41.5 61 41.5 43 57 41.5 61 57 41.5 61 43
AC25 55 57 74 57 55 76 57 57 55 76 74 57 55 76 55 57 74 55 76 74 55 76 57
AC30 55 57 74 57 55 76 57 57 55 76 74 57 55 76 55 57 74 55 76 74 55 76 57
AC40 72.5 75 95 75 72.5 99 75 75 72.5 99 95 75 72.5 99 72.5 75 95 72.5 99 95 72.5 99 75
AC40-06 77.5 104 77.5 80 102 77.5 104 102 77.5 104 80
AC50 93 124 93 96 124 93 124 124 93 124 96
AC55 98 124
AC60 98 129
Attachment
K S V KS KV KSV SV
Model L1 L2 L1 L1 L2 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2
AC20A 41.5 43 41.5 41.5 43 41.5 57 41.5 43 43 41.5 57 43 41.5 57
AC30A 55 57 55 55 57 55 74 55 57 57 55 74 57 55 74
AC40A 72.5 75 72.5 72.5 75 72.5 95 72.5 75 75 72.5 95 75 72.5 95
AC40A-06 77.5 77.5 80 77.5 102
Attachment
S T V SV TV
Model L1 L1 L1 L2 L1 L2 L1 L2
AC10B 28
AC20B 41.5 41.5 41.5 43 41.5 57 41.5 61
AC25B 55 55 55 57 55 74 55 76
AC30B 55 55 55 57 55 74 55 76
AC40B 72.5 72.5 72.5 75 72.5 95 72.5 99
AC40B-06 77.5 77.5 77.5 80 77.5 102 77.5 104
AC50B 93 93 93 96 93 124 93 124
AC55B 98 98
AC60B 98 98
Attachment
S T V SV TV
Model L1 L2 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2 L3
AC20C 41.5 43 41.5 43 41.5 43 43 41.5 43 57 41.5 43 61
AC25C 55 57 55 57 55 57 57 55 57 74 55 57 76
AC30C 55 57 55 57 55 57 57 55 57 74 55 57 76
AC40C 72.5 75 72.5 75 72.5 75 75 72.5 75 95 72.5 75 99
AC40C-06 77.5 80 77.5 80 77.5 80 80 77.5 80 102 77.5 80 104
Attachment
S V SV L1: Dimensions from the end of the IN side to the center of the mounting hole for the first bracket.
Model L1 L1 L2 L1 L2 L2: Mounting hole pitch between the first and the second bracket.
AC20D 41.5 41.5 43 41.5 57 L3: Mounting hole pitch between the second and the third bracket.
AC30D 55 55 57 55 74 L4: Mounting hole pitch between the third and the fourth bracket.
AC40D 72.5 72.5 75 72.5 95 Refer to dimensions pages for dimension A from the center of the piping and the mounting hole.
AC40D-06 77.5 77.5 80 77.5 102
14-2-30
F.R.L. Unit Series AC20 to 60
Made to Order Specifications:
Please contact SMC for detailed dimensions, specifications, and lead times.
F.R.L.
AV
AU
AF
AR
IR
Specifications VEX
Part no. -X465
Model ISE30---L AMR
Set pressure range 0.1 to 1 MPa
Pressure
Set/Display resolution 0.001 MPa ITV
switch
Power supply voltage 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With reverse connection protection)
Current consumption 45 mA or less (70 mA or less during current output)
IC
Pressure gauge port size: Rc 1/8
VBA
Applicable Model VE
Model AC20 AC25 AC30 AC40 AC40-06 AC50 AC55 AC60
14-2-31
Series AC
How to Order
AC 30 A F 03 D KV 12R X465 A
Switch specifications
F.R.L. unit
Symbol Output specifications
Body size A NPN output
20 25 30 40 50 55 60 B PNP output
C 1 to 5 V output
Model combination D 4 to 20 mA output
Combination With digital pressure switch
Symbol Filter Mist
Air filter Regulator Lubricator Regulator Separator (Series ISE30) (12)
Nil (1) (2) (3) Note 12) Digital pressure switch is not
A (2) (1) mounted and is supplied
loose at the time of
B (1) (2) Description shipment.
C (1) (3) (2) Symbol Description Applicable model
D (1) (2) 1 (9) 0.02 to 0.2 MPa setting AC20 to 60
Note 1) The circled numbers indicate the 2 Metal bowl AC20 to 60
order in which the units are
assembled. 3 Lubricator with drain cock AC20 to 60
6 Nylon bowl (Including sight dome) AC20 to 60
Thread type
8 Metal bowl with level gauge AC25 to 60
Nil Rc C With bowl guard AC20
N (2) NPT J (10) Drain guide 1/4 AC25 to 60
F (3) G N Non-relieving type AC20 to 60
Note 2) Drain guide is NPT 1/4 (applicable R Flow direction: Right Left AC20 to 60
to AC25 to 60), and the exhaust
port for auto-drain comes with 3/8" Drain cock with barb fitting:
W AC25 to 60
One-touch fitting (applicable to 6 x 4 nylon tubing
AC25 to 60).
Name plate and caution plate for
Note 3) Drain guide is G 1/4 (applicable to Z (11) bowl in imperial units (PSI, F) AC20 to 60
AC25 to 60).
Port size When more than one specification is required, indicate
Port Body size in ascending alphanumeric order.
Symbol
size 20 25 30 40 50 55 60 Note 9) The only difference from the standard
01 1/8 specifications is the adjusting spring for
the regulator. It does not restrict the
02 1/4
setting of 0.2 MPa or more.
03 3/8 Note 10) Without a valve function.
04 1/2 Note 11) For thread type NPT.
06 3/4 This product is for overseas use only
10 1 according to the new Measurement Law.
(The SI unit type is provided for use in
Japan.)
Accessory Attachment
Symbol Description Applicable model Attachment Port size for
Symbol Description Applicable model intermediate
Nil mounting position air release
C With float type auto-drain (N.C.) (4) AC20 to 60 Nil None
D With float type auto-drain (N.O.) (4) AC25 to 60 AF + AR + [K] + AL AC20: 1/8
AC20 to 40
K Check valve AC25: 1/4
Note 4) Applicable tubing O.D for auto drain connection should be AW + [K] + AL AC20A to 40A AC30: 1/4
AC40: 3/8
3/8" in case NPT thread port is chosen.
AC20: 1/8
AF + [T] + AR + AL AC20 to 60 AC25: 1/4
AC30: 1/4
T T-interface AF + [T] + AR AC20B to 60B AC40: 3/8
AC50: 3/8
AF + AFM + [T] + AR AC20C to 40C AC55: 1/2
AC60: 1/2
AF + AR + AL + [V] AC20 to 50
Note 13) Please consult with SMC for detailed AW + AL + [V] AC20A to 40A
dimensions and available attachments and Residual
V pressure relief
AF + AR + [V] AC20B to 50B
options.
Note 14) Refer to SMC catalog CAT.ES100-42 for 3 port valve AF + AFM + AR + [V] AC20C to 40C
detailed specifications and instructions of AW + AFM + [V] AC20D to 40D
digital pressure switch. [V] + AF + ARK AC20B to 50B
Residual
V1 (8) pressure relief [V] + AF + AFM + ARK AC20C to 40C
3 port valve
[V] + AWK+ AFM AC20D to 40D
Note 5) When more than one attachment is required, order in alphabetical order.
Note 6) Piping adapter, pressure switch with piping adapter, and cross interface need to be
ordered separately.
Note 7) The bracket position varies depending on the T-interface mounting.
Refer to the table on page 14-2-30 for standard bracket position.
Note 8) With this combination, requlators and filter requlators will be With back flow function type.
For safety, check that the ezhausted and is atmospheric pressure by pressure gauge.
14-2-32
F.R.L. Unit Series AC
How to Order
AC 30 A F 03 DE KV 12R
Option
F.R.L. unit Symbol Description Applicable model
1 (11) 0.02 to 0.2 MPa setting AC10 to 60
Body size
2 Metal bowl AC10 to 60
10 20 25 30 40 50 55 60
3 Lubricator with drain cock AC10 to 60
6 Nylon bowl AC10 to 60
F.R.L.
8 Metal bowl with level gauge AC25 to 60
C With bowl guard AC25 to 60
AV
J (12) Drain guide 1/4 AC10 to 60
Model combination
N Non-relieving type AC10 to 60
Combination AU
Symbol Filter Mist R Flow direction: Right Left AC10 to 60
Air filter Regulator Lubricator regulator separator
Nil (1) (2) (3) W Drain cock with barb fitting:
6 x 4 nylon tubing
AC25 to 60 AF
A (2) (1)
(13)
B (1) (2) Z
Name plate, caution plate for bowl, and
pressure gauge in imperial units (PSI, F)
AC10 to 60 AR
C (1) (3) (2)
When more than one specification is required, indicate
D (1) (2) in ascending alphanumeric order.
IR
Note 1) The number inside ( ) indicates the Note 11) The only difference from the standard
combination order counted from the specifications is the adjusting spring for VEX
inlet side. the regulator. It does not restrict the
setting of 0.2 MPa or more.
Note 12) Without a valve function. AMR
Note 13) For thread types M5 and NPT.
This product is for overseas use only
Thread type according to the new Measurement Law.
ITV
(The SI unit type is provided for use in
Metric system thread (M5)
Nil Japan.) IC
Rc Pressure switch comes with a dual unit
N (2) NPT scale in SI (MPa) and imperial (PSI)
units. VBA
F (3) G Attachment
Note 2) Drain guide is NPT 1/4 (applicable to AC25 Port size for
to 60), and the exhaust port for auto-drain Symbol Description Attachment
mounting position
Applicable
model
intermediate
air release
VE
comes with 3/8" One-touch fitting Nil None
(applicable to AC25 to 60).
AF + AR + [K] + AL AC20 to 40 AC20: 1/8 VY1
Note 3) Drain guide is G 1/4 (applicable to AC25 to AC25: 1/4
60). K Check valve
AC30: 1/4
AW + [K] + AL AC20A to 40A AC40: 3/8 G
AF + AR + [S] + AL AC20 to 60
Port size
AW + [S] + AL AC20A to 40A PPA
Port Body size Pressure
Symbol size S AF + [S] + AR AC20B to 60B
switch
10 20 25 30 40 50 55 60
AF + AFM + [S] + AR AC20C to 40C AL
M5 M5
AW + [S] + AFM AC20D to 40D
01 1/8
AC10: M5 x 0.8
02 1/4 AF + [T] + AR + AL AC10 to 60AC20: 1/8
03 3/8 AC25: 1/4
T T-interface AC30: 1/4
04 AF + [T] + AR AC10B to 60B AC40: 3/8
1/2
AC50: 3/8
06 3/4
AF + AFM + [T] + AR AC20C to 40C AC55: 1/2
10 1 AC60: 1/2
AF + AR + AL + [V] AC20 to 50
AW + AL + [V] AC20A to 40A
Residual
V pressure relief AF + AR + [V] AC20B to 50B
3 port valve
Accessory AF + AFM + AR + [V] AC20C to 40C
Symbol Description Applicable model AW + AFM + [V] AC20D to 40D
Nil [V] + AF + ARK AC20B to 50B
Residual
C Float type auto-drain (N.C.) (4) AC10 to 60 V1 pressure relief [V] + AF + AFM + ARK AC20C to 40C
3 port valve
D Float type auto-drain (N.O.) (4) AC25 to 60 [V] + AWK + AFM AC20D to 40D
E With square embedded type pressure gauge (With limit indicator) AC20 to 60 Note 6) When more than one attachment is required, order in
With round pressure gauge (Without limit indicator)
alphabetical order.
(5) AC10
G Note 7) Piping adapter, pressure switch with piping adapter,
With round pressure gauge (With limit indicator) AC20 to 60 and cross interface need to be ordered separately.
Note 4) Applicable tubing O.D for auto-drain connection should be Note 8) Please contact SMC when using a pressure switch
3/8" in case NPT thread port is chosen. and T-interface together for ACB.
Note 5) Mounting thread for pressure gauge: Note 9) The bracket position varies depending on the T-
1/16 for AC10; 1/8 for AC20 to 30; 1/4 for AC40 to 60 interface or pressure switch mounting. Refer to the
Pressure gauge is not mounted and is supplied loose at the table on page 14-2-30 for standard bracket position.
time of shipment. Note 10) With this combination, regulators and filter regulators
will be with back flow function type.
For safety, check that the outlet pressure is exhausted
and is atmospheric pressure by pressure gauge.
14-2-9
Series AC
Accessory/Optional Specifications Combination
: Combination available : Combination not available : Varies depending on the model : Available only with NPT thread
F.R.L. unit applicable model
Symbol
Combination Accessory Optional specifications
Accessory/ AC10 AC20 AC20B AC25B AC30 AC30A AC30B AC30C AC30D
AC10B AC20C AC25 to to
Optional specifications C D E G 1 2 3 6 8 C J N R WZ AC10A AC20A AC20D AC25C AC60 AC40A AC60B AC40C AC40D
Nylon bowl -6
Metal bowl with level gauge -8
Attachment
Port size Function
M5 x 0.8 P. 14-2-24
T-interface 1/8, 1/4, 3/8, 1/2
Redirects the air flow.
Check valve 1/8, 1/4, 3/8 Prevents back flow from lubricator. P. 14-2-26
M5 x 0.8 P. 14-2-27
Cross interface 1/8, 1/4, 3/8, 1/2
Allows piping in all 4 directions.
Residual pressure relief 1/8, 1/4, 3/8, 1/2, 3/4, 1 Releases residual pressure in lines. P. 14-2-28
3 port valve
14-2-10
F.R.L. Unit Air Filter + Regulator
JIS Symbol
AC20B AC40B
Air filter Regulator
Standard Specifications
Model AC10B AC20B AC25B AC30B AC40B AC40B-06 AC50B AC55B AC60B
Air filter AF10 AF20 AF30 AF30 AF40 AF40-06 AF50 AF60 AF60
Component
Regulator AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR50 AR60
1/8 1/4 1/4 1/4 3/4
Port size M5 x 0.8 3/8 3/4 1 1
1/4 3/8 3/8 1/2 1
(1)
Pressure gauge port size 1/16 1/8 1/8 1/8 1/4 1/4 1/4 1/4 1/4
Fluid Air
Proof pressure 1.5 MPa
Max. operating pressure 1.0 MPa
Set pressure range 0.05 to 0.7 MPa 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (2) (at relief flow rate of 0.1 l/min (ANR))
Ambient and 5 to 60C (With no freezing)
fluid temperature
Nominal filtration rating 5 m
Bowl material Polycarbonate
Bowl guard Option Standard
Regulator construction Relieving type
Weight (kg) 0.16 0.51 0.55 0.63 1.12 1.16 2.44 2.45 2.54
Note 1) Pressure gauge connection threads are not required for F.R.L. unit with a square embedded type pressure gauge (AC20B to AC60B).
Note 2) Not applicable to AC10B.
Round type G27-10-R1 G36-10-01 G36-10-01 G36-10-01 G46-10-02 G46-10-02 G46-10-02 G46-10-02 G46-10-02
1.0 MPa Square (2)
embedded type GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS
Accessory
Round type G27-10-R1 (3) G36-2-01 G36-2-01 G36-2-01 G46-2-02 G46-2-02 G46-2-02 G46-2-02 G46-2-02
0.2 MPa Square (2)
GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS
embedded type
(4)
Float type N.O. AD38 AD38N (7) AD38 AD38N (7) AD48 AD48N (7) AD48 AD48N (7) AD48 AD48N (7) AD48 AD48N (7) AD48 AD48N (7)
auto-drain N.C. AD17 AD27 AD37 AD37N (7) AD37 AD37N (7) AD47 AD47N (7) AD47 AD47N (7) AD47 AD47N (7) AD47 AD47N (7) AD47 AD47N (7)
Spacer Y100 Y200 Y300 Y300 Y400 Y500 Y600 Y600 Y600
Pressure switch (6) IS1000M-20 IS1000M-30 IS1000M-30 IS1000M-40 IS1000M-50 IS1000M-60 IS1000M-60 IS1000M-60
(5) 01 03
T-interface (6) Y110-M5 Y210- (02) Y310-(01)
02 Y310- (01)
02 Y410- (02)
03 Y510- (02)
03 Y610- (04) Y610- (03)
04 Y610- (03)
04
Attachment
(6) 02
02 02
Residual pressure
relief 3 port valve
VHS20- 01 06
02 VHS30- 03 VHS30- 03 VHS40- 03 VHS40-06 VHS50- 10
04
02
(6) 01 02 02
Piping adapter E100-M5 E200- 02 E300- 03 E300- 03 E400- 03
04 E500-06 E600- 06
10 E600- 06
10 E600- 06
10
03 04 04 06
02
Pressure switch (6) 01 02 02 03
IS1000E-20 02 IS1000E-30 03 IS1000E-30 03 IS1000E-40 04
with piping adapter 03 04 04 06
(6)
Cross interface Y14-M5 Y24- 01
02 Y34- 01
02 Y34- 01
02 Y44- 02
03 Y54- 03
04
Note 1) in part numbers for a round pressure gauge indicates a type of connection thread. No indication is necessary for R; however, indicate N
for NPT.
Please contact SMC regarding the connection thread NPT and pressure gauge supply for PSI unit specifications.
Note 2) Includes one O-ring and 2 mounting screws.
Note 3) For 1.0 MPa.
Note 4) Minimum operating pressure: N.O. type0.1 MPa; N.C. type0.1 MPa (AD17/27), 0.15 MPa (AD37/47).
Note 5) For F.R.L. units, port sizes not in ( ) are for standard application.
Note 6) Separate interfaces are required for modular unit.
Note 7) When N is specified in the end of part number of auto-drain, applicable tubing O.D should be 3/8".
14-2-18
F.R.L. Unit Series AC10B to 60B
Dimensions
AC10B/20B A Pressure gauge port size
F P E
K
N
Q
G
IN OUT
T
K
G
H
Pressure gauge
B
(Option)
J Square embedded type L
pressure gauge F.R.L.
(Option)
Port size AV
Min. clearance M
Drain
D
Air filter Regulator for maintenance AU
AC25B/30B/40B/50B/55B/60B
F
A
Pressure gauge port size AF
P E
K
N
Q
AR
G
C
IN OUT IR
T
VEX
G
K
Pressure gauge
B
(Option)
J L AMR
Square embedded type
pressure gauge
(Option) ITV
Port size
IC
Drain Min. clearance
M
D
B
B
B
specifications
B
N.O.: Black
G
B
O S N.C.: Gray O
S
M5 x 0.8 10 One-touch 1/4 Barb fitting
fitting Width across flats 17 Applicable tubing: T0604
PPA
(mm)
Standard specifications Accessory specifications AL
Model Port size Bracket mounting size With pressure gauge With auto-drain
A B C D
E F G H J K K L M N P Q T B
AC10B M5 x 0.8 56 71 11 25 25 28 20 27 7 4.5 4.5 2.8 40 13.5 26 0 89
AC20B 1/8, 1/4 83 114 26.5 40 30 41.5 24 33 12 5.5 5.5 3.2 50 2.5 65 29.5 2 (1) 132
AC25B 1/4, 3/8 110 143 28 50 41 55 35 14 7 7 4 71 13 64 28.5 0 184
AC30B 1/4, 3/8 110 146 31 50 41 55 35 14 7 7 4 71 10 66 30.5 3.5 187
AC40B 1/4, 3/8, 1/2 145 183 36 75 50 72.5 40 18 9 9 4 88 12 74 35 3.5 222
AC40B-06 3/4 155 185 36 75 50 77.5 40 18 9 9 4.6 88 12 74 35 3 224
AC50B 3/4, 1 186 264 43 20 70 93 50 20 11 11 6.4 115 16 84 44.5 3.3 303
AC55B 1 191 277 43 20 70 98 50 20 11 11 6.4 117.5 16 84 44.5 3.3 316
AC60B 1 196 280 46 20 70 98 50 20 11 11 6.4 117.5 13 84 44.5 3.3 319
Optional specifications (2) Note 1) For AC20 only, the position of the pressure gauge is above the
center of the piping.
Model With barb fitting With drain guide Metal bowl Metal bowl with level gauge
Note 2) For optional specifications (with barb fitting, with drain guide,
B B B B with metal bowl, or with level gauge), the total length
AC10B 70 (dimension for B) will vary.
AC20B 114
AC25B 151 150 156 176
AC30B 154 153 159 179
AC40B 191 190 196 216
AC40B-06 193 192 198 218
AC50B 272 271 277 297
AC55B 285 284 290 310
AC60B 288 287 293 313
14-2-19
F.R.L. Unit Series AC
Attachment Specifications
Piping Adapter (E): M5 x 0.8, 1/8, 1/4, 3/8, 1/2, 3/4, 1
A piping adapter allows installation/removal of the component Port size
without removing the piping and thus makes maintenance easier.
B
Center of
F.R.L. body
A D
(mm)
Model Note) Port size A B D Applicable model
E100-M5 M5 x 0.8 10 14 14 AC10, AW10, AF10, AR10, AL10
E200-01 1/8 AC20
E200-02 1/4 30 23.5 28 AF20, AR20, AW20
E200-03 3/8 AL20, AFM20, AFD20, AWM20, AWD20
Piping adapter E300-02 1/4 AC25, AC30
E300-03 3/8 32 30 30 AF30, AR30, AW30
E300-04 1/2 AL30, AFM30, AFD30, AWM30, AWD30
E400-02 1/4 AC40
E400-03 3/8 AF40, AR40, AW40
32 36 36 AL40, AFM40, AFD40
E400-04 1/2
AWM40, AWD40
E400-06 3/4
AC40-06, AF40-06, AR40-06, AW40-06
E500-06 3/4 32 40 44
AL40-06, AFM40-06, AFD40-06
E600-06 3/4 AC50, AC55, AC60, AC50B, AC55B, AC60B
35 48 53
E600-10 1 AF50, AR50, AL50, AF60, AR60, AL60
Note) in model numbers indicates a thread type. No indication is
necessary for Rc; however, indicate N for NPT, and F for G.
Separate interfaces are required for modular unit.
Factory mounting of a piping adapter on the AC models is available as a
special order.
T-interface
Center of
F.R.L. body
A D
(mm)
Model Port size A B C D E Applicable model
Y110-M5 M5 x 0.8 11 19 12 14 8 AC10, AC10B
Y210-01 1/8 AC20, AC20B
15 42 32 28 19
Y210-02 1/4 AC20C
Y310-01 1/8 AC25, AC25B
15 53 39 30 19 AC25C, AC30
Y310-02 1/4 AC30B, AC30C
Y410-02 1/4 AC40, AC40B
19 62 44 36 24
Y410-03 3/8 AC40C
Y510-02 1/4 AC40-06, AC40B-06
19 66 46 44 24
Y510-03 3/8 AC40C-06
Caution on Mounting AC50, AC55
Y610-03 3/8
If a T-interface is used on the IN side of the lubricator, lubricant 22 81 57 53 30
AC60, AC50B
Y610-04 1/2 AC55B, AC60B
may be mixed. Use the Series AKM check valve to avoid such
possibility. Note) in model numbers indicates a thread type. No indication is
necessary for Rc; however, indicate N for NPT, and F for G.
Separate interfaces are required for modular unit.
Refer to the attachment table on Front matter 2 for standard port sizes
when using with AC.
14-2-24
Attachment Specifications Series AC
Pressure Switch with Piping Adapter (P)
Approx. 500
Pressure switch with piping adapter
A D
E 23
JIS Symbol
C
AV
B
AU
Specifications
Fluid Air AF
Proof pressure 1.0 MPa Center of
F.R.L. body
Maximum operating pressure 0.7 MPa AR
Set pressure range (mm)
(When OFF) 0.1 to 0.4 MPa
Differential 0.08 MPa
Model (1) Port size A B C D E Applicable model IR
IS1000E-2001 1/8 AC20
Ambient and fluid temperature 5 to 60C (With no freezing)
IS1000E-2002 1/4 30 68 57 28 16 AR20, AW20 VEX
IS1000E-2003 3/8 AWM20, AWD20
Switch characteristics
Contact point configuration 1a
IS1000E-3002 1/4 AC25, AC30 AMR
IS1000E-3003 3/8 32 74.5 60.5 30 13 AR25, AR30, AW30
Maximum contact point capacity 2 VA(AC), 2 W(DC)
Operating voltage: AC, DC 100 V or less
IS1000E-3004 1/2 AWM30, AWD30 ITV
IS1000E-4002 1/4
12 V to 24 VAC, DC: 50 mA
Maximum operating current 48 VAC, DC: 40 mA IS1000E-4003 3/8
32 80.5 62.5 37 12.5
AC40 (2) IC
100 VAC, DC: 20 mA IS1000E-4004 1/2 AR40, AW40
AWM40, AWD40
IS1000E-4006 3/4 VBA
Note 1) in the model numbers indicates a thread type. No indication
is necessary for Rc; however, indicate N for NPT, and F for G.
Note 2) A pressure switch cannot be mounted on AC40-06 and VE
AW40-06.
Separate interfaces are required for modular unit. VY1
The pressure switch on AC40-06 and above and AW40-06 can
be mounted by screwing IS1000-01 into the piping adapter E500-
06-X501 or E600-06-X501 to E600-06 to 10-X501 (with top- G
face thread Rc 1/8). Products with a premounted switch are
available as a special order. Please contact SMC regarding their
availability.
PPA
How to Order AL
IS1000E 30 03
Option
Pressure switch X201 Lead wire length: 3 m
with piping X202 Regulating pressure range: 0.1 to 0.6 MPa
adapter X207 MPa/PSI Dual scale
Body size X215 Lead wire length: 3 m; Regulating pressure range: 0.1 to 0.6 MPa
30 For AC25, AC30 X251 Lead wire length: 3 m; Opposite-side mounting (Left-side mounting style)
Set pressure range: 0.1 to 0.6 MPa; Opposite-side mounting
40 For AC40-02 to 04 X252 (Left-side mounting style)
Lead wire length: 3 m; Regulating pressure range: 0.1 to 0.6 MPa;
Thread type X253
Opposite-side mounting (Left-side mounting style)
Nil Rc
This product is for overseas use only according to the new Measurement Law.
N NPT (The SI unit type is provided for use in Japan.)
F G
Piping adapter port size
Port Body size
Symbol
size 20 30 40
01 1/8
02 1/4
03 3/8
04 1/2
06 3/4
14-2-25
Attachment Specifications Series AC
Pressure Switch (S)
Approx. 500
A compact integrated pressure switch can be easily installed and
facilitates the pressure detection of the line.
15 23
Pressure switch
F.R.L.
C
B
JIS Symbol
AV
AU
Center of
F.R.L. body AF
A D
Specifications (mm) AR
Fluid Air Model A B C D Applicable model
Proof pressure 1.0 MPa IS1000M-20 11 76 66 28 AC20 IR
Maximum operating pressure 0.7 MPa IS1000M-30 13 86 72 30 AC25, AC30
Set pressure range (Off) 0.1 to 0.4 MPa IS1000M-40 15 95 77 36 AC40 VEX
Differential 0.08 MPa IS1000M-50 17 99 79 44 AC40-06
Ambient and fluid temperature 5 to 60C (With no freezing) IS1000M-60 22 92.5 68.5 53 AC50, AC55B, AC60 AMR
Note) Separate interfaces are required for modular unit.
ITV
Switch Characteristics How to Order
Contact point configuration 1a IC
Maximum contact point capacity
Operating voltage: AC, DC
2 VA(AC), 2 W(DC)
100 V or less
IS1000M 30 VBA
12 V to 24 VAC, DC : 50 mA
Pressure switch Accessory
Maximum operating current 48 VAC, DC : 40 mA X201 Lead wire length: 3 m VE
100 VAC, DC : 20 mA
Body size
Regulating pressure
20 For AC20 X202 range: 0.1 to 0.6 MPa
30 For AC25, AC30 VY1
X207 MPa/PSI dual scale
40 For AC40-02 to 04 Lead wire length: 3 m;
50 For AC40-06 X215 Regulating pressure
G
60 For AC50, AC55, AC60 range: 0.1 to 0.6 MPa
This product is for overseas use PPA
only according to the new
Measurement Law. (The SI unit
type is provided for use in Japan.)
AL
Cross Interface (C): M5 x 0.8, 1/8, 1/4, 3/8, 1/2
Center of
Pipings are possible in all 4 directions. F.R.L. body Port size
E
IN/OUT ports are not machined for threads. Please
contact SMC if threaded (machined) ports are required.
F
B
C
F E E
Cross interface
E: 4-Rc
A E
F: Without thread D
(mm)
Model Port size A B C D Applicable model
Y14-M5 M5 23 16 14 25 AC10
Y24-01 1/8
40 40 22 40 AC20
Y24-02 1/4
Y34-01 1/8
49 43 28 48 AC25, AC30
Y34-02 1/4
Y44-02 1/4
Caution on Mounting 60 48 36 54 AC40
Y44-03 3/8
When mounting a cross interface directly on the IN side of the Y54-03 3/8
lubricator, be sure to use a Series AKM check valve between the 72 62 40 62 AC40-06
Y54-04 1/2
lubricator and cross interface.
Note) in the model numbers indicates a thread type. No indication is
Factory mounting of a cross interface on the AC model is necessary for Rc; however, indicate N for NPT, and F for G.
available as a special order. If threaded ports are required, they are available as a special order.
Please contact SMC.
14-2-27
Spacers and Brackets Series AC
Accessory Dimensions
Spacer (X)
D
Center of
F.R.L. body
F.R.L.
C
1
X-X AV
B
RELEASE
X
2
Y200 Y400 AU
(mm)
X
Model A B C D Applicable model
AF
Seal
Y100 6 27 15 33 AC10, AC10A, AC10B
Y200 3 35.5 18.5 48 AC20 AR
Y300 4 47 26 59 AC25, AC30
Y400 5 57 31 65 AC40 A IR
Y500 5 61 33 70 AC40-06 Spacer width
Y600 6 75.5 41 86
AC50, AC55, AC60 VEX
AC50B, AC55B, AC60B
VY1
Center of
F.R.L. body
G
C
1
X-X PPA
EE (Y100T, Y200T only)
RELEASE
X
2
AL
E
X
G
Seal
Y200T Y400T
F J
A
H K
Spacer width
D
(mm)
Model A B BB C D E EE F G G H J K Applicable model
Y100T 6 56 24.5 40.5 20 27 6.8 4.5 4.5 14 2.8 25 AC10
Y200T 3 67 29 53 24 33 12 5.5 5.5 19 3.2 30 AC20
Y300T 4 82 41 68 35 14 7 7 21 4 41 AC25, AC30
Y400T 5 96 48 81.5 40 18 9 9 26 4 50 AC40
Y500T 5 96 48 86 40 18 9 9 27 4.6 50 AC40-06
Y600T 6 120 60 112 50 20 11 11 31 6.4 70 AC50, AC55, AC60, AC50B, AC55B, AC60B
Replacement Parts
Part no.
Description Material
Y100T Y200T Y300T Y400T Y500T Y600T
Seal HNBR (2) Y100P-060AS (1) Y200P-060S Y300P-060S Y400P-060S Y500P-060S Y600P-060S
Note 1) Y-100T comes with 2 O-rings.
Note 2) NBR seal is used for Y100T spacer because of no direct contact with fluid.
14-2-29
Series AC
Mounting Position for Spacer with Bracket
Bracket
Pressure switch: S Residual pressure
T-interface: T Check valve: K relief 3 port valve: V
SUP.
SUP
A
A
IN OUT IN OUT
A
A
Bracket
L1 L2 L3 L4 L1
(mm)
Attachment K S T V KS KT KV KST
Model L1 L2 L3 L1 L2 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L4 L1 L2 L3
AC10 28 48
AC20 41.5 43 43 41.5 43 41.5 61 41.5 43 43 41.5 43 57 41.5 61 43 41.5 43 43 43 41.5 61 57
AC25 55 57 57 55 57 55 76 55 57 57 55 57 74 55 76 57 55 57 57 57 55 76 74
AC30 55 57 57 55 57 55 76 55 57 57 55 57 74 55 76 57 55 57 57 57 55 76 74
AC40 72.5 75 75 72.5 75 72.5 99 72.5 75 75 72.5 75 95 72.5 99 75 72.5 75 75 75 72.5 99 95
AC40-06 77.5 80 77.5 104 77.5 80 80
AC50 93 96 93 124 93 96 96
AC55 98 96 98 124
AC60 98 101 98 129
Attachment KSV KTV KSTV ST SV STV TV
Model L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2 L3
AC10
AC20 41.5 43 57 43 41.5 61 43 43 41.5 61 57 43 41.5 61 41.5 43 57 41.5 61 57 41.5 61 43
AC25 55 57 74 57 55 76 57 57 55 76 74 57 55 76 55 57 74 55 76 74 55 76 57
AC30 55 57 74 57 55 76 57 57 55 76 74 57 55 76 55 57 74 55 76 74 55 76 57
AC40 72.5 75 95 75 72.5 99 75 75 72.5 99 95 75 72.5 99 72.5 75 95 72.5 99 95 72.5 99 75
AC40-06 77.5 104 77.5 80 102 77.5 104 102 77.5 104 80
AC50 93 124 93 96 124 93 124 124 93 124 96
AC55 98 124
AC60 98 129
Attachment
K S V KS KV KSV SV
Model L1 L2 L1 L1 L2 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2
AC20A 41.5 43 41.5 41.5 43 41.5 57 41.5 43 43 41.5 57 43 41.5 57
AC30A 55 57 55 55 57 55 74 55 57 57 55 74 57 55 74
AC40A 72.5 75 72.5 72.5 75 72.5 95 72.5 75 75 72.5 95 75 72.5 95
AC40A-06 77.5 77.5 80 77.5 102
Attachment
S T V SV TV
Model L1 L1 L1 L2 L1 L2 L1 L2
AC10B 28
AC20B 41.5 41.5 41.5 43 41.5 57 41.5 61
AC25B 55 55 55 57 55 74 55 76
AC30B 55 55 55 57 55 74 55 76
AC40B 72.5 72.5 72.5 75 72.5 95 72.5 99
AC40B-06 77.5 77.5 77.5 80 77.5 102 77.5 104
AC50B 93 93 93 96 93 124 93 124
AC55B 98 98
AC60B 98 98
Attachment
S T V SV TV
Model L1 L2 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2 L3
AC20C 41.5 43 41.5 43 41.5 43 43 41.5 43 57 41.5 43 61
AC25C 55 57 55 57 55 57 57 55 57 74 55 57 76
AC30C 55 57 55 57 55 57 57 55 57 74 55 57 76
AC40C 72.5 75 72.5 75 72.5 75 75 72.5 75 95 72.5 75 99
AC40C-06 77.5 80 77.5 80 77.5 80 80 77.5 80 102 77.5 80 104
Attachment
S V SV L1: Dimensions from the end of the IN side to the center of the mounting hole for the first bracket.
Model L1 L1 L2 L1 L2 L2: Mounting hole pitch between the first and the second bracket.
AC20D 41.5 41.5 43 41.5 57 L3: Mounting hole pitch between the second and the third bracket.
AC30D 55 55 57 55 74 L4: Mounting hole pitch between the third and the fourth bracket.
AC40D 72.5 72.5 75 72.5 95 Refer to dimensions pages for dimension A from the center of the piping and the mounting hole.
AC40D-06 77.5 77.5 80 77.5 102
14-2-30
F.R.L. Unit Series AC20 to 60
Made to Order Specifications:
Please contact SMC for detailed dimensions, specifications, and lead times.
F.R.L.
AV
AU
AF
AR
IR
Specifications VEX
Part no. -X465
Model ISE30---L AMR
Set pressure range 0.1 to 1 MPa
Pressure
Set/Display resolution 0.001 MPa ITV
switch
Power supply voltage 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With reverse connection protection)
Current consumption 45 mA or less (70 mA or less during current output)
IC
Pressure gauge port size: Rc 1/8
VBA
Applicable Model VE
Model AC20 AC25 AC30 AC40 AC40-06 AC50 AC55 AC60
14-2-31
Series AC
How to Order
AC 30 A F 03 D KV 12R X465 A
Switch specifications
F.R.L. unit
Symbol Output specifications
Body size A NPN output
20 25 30 40 50 55 60 B PNP output
C 1 to 5 V output
Model combination D 4 to 20 mA output
Combination With digital pressure switch
Symbol Filter Mist
Air filter Regulator Lubricator Regulator Separator (Series ISE30) (12)
Nil (1) (2) (3) Note 12) Digital pressure switch is not
A (2) (1) mounted and is supplied
loose at the time of
B (1) (2) Description shipment.
C (1) (3) (2) Symbol Description Applicable model
D (1) (2) 1 (9) 0.02 to 0.2 MPa setting AC20 to 60
Note 1) The circled numbers indicate the 2 Metal bowl AC20 to 60
order in which the units are
assembled. 3 Lubricator with drain cock AC20 to 60
6 Nylon bowl (Including sight dome) AC20 to 60
Thread type
8 Metal bowl with level gauge AC25 to 60
Nil Rc C With bowl guard AC20
N (2) NPT J (10) Drain guide 1/4 AC25 to 60
F (3) G N Non-relieving type AC20 to 60
Note 2) Drain guide is NPT 1/4 (applicable R Flow direction: Right Left AC20 to 60
to AC25 to 60), and the exhaust
port for auto-drain comes with 3/8" Drain cock with barb fitting:
W AC25 to 60
One-touch fitting (applicable to 6 x 4 nylon tubing
AC25 to 60).
Name plate and caution plate for
Note 3) Drain guide is G 1/4 (applicable to Z (11) bowl in imperial units (PSI, F) AC20 to 60
AC25 to 60).
Port size When more than one specification is required, indicate
Port Body size in ascending alphanumeric order.
Symbol
size 20 25 30 40 50 55 60 Note 9) The only difference from the standard
01 1/8 specifications is the adjusting spring for
the regulator. It does not restrict the
02 1/4
setting of 0.2 MPa or more.
03 3/8 Note 10) Without a valve function.
04 1/2 Note 11) For thread type NPT.
06 3/4 This product is for overseas use only
10 1 according to the new Measurement Law.
(The SI unit type is provided for use in
Japan.)
Accessory Attachment
Symbol Description Applicable model Attachment Port size for
Symbol Description Applicable model intermediate
Nil mounting position air release
C With float type auto-drain (N.C.) (4) AC20 to 60 Nil None
D With float type auto-drain (N.O.) (4) AC25 to 60 AF + AR + [K] + AL AC20: 1/8
AC20 to 40
K Check valve AC25: 1/4
Note 4) Applicable tubing O.D for auto drain connection should be AW + [K] + AL AC20A to 40A AC30: 1/4
AC40: 3/8
3/8" in case NPT thread port is chosen.
AC20: 1/8
AF + [T] + AR + AL AC20 to 60 AC25: 1/4
AC30: 1/4
T T-interface AF + [T] + AR AC20B to 60B AC40: 3/8
AC50: 3/8
AF + AFM + [T] + AR AC20C to 40C AC55: 1/2
AC60: 1/2
AF + AR + AL + [V] AC20 to 50
Note 13) Please consult with SMC for detailed AW + AL + [V] AC20A to 40A
dimensions and available attachments and Residual
V pressure relief
AF + AR + [V] AC20B to 50B
options.
Note 14) Refer to SMC catalog CAT.ES100-42 for 3 port valve AF + AFM + AR + [V] AC20C to 40C
detailed specifications and instructions of AW + AFM + [V] AC20D to 40D
digital pressure switch. [V] + AF + ARK AC20B to 50B
Residual
V1 (8) pressure relief [V] + AF + AFM + ARK AC20C to 40C
3 port valve
[V] + AWK+ AFM AC20D to 40D
Note 5) When more than one attachment is required, order in alphabetical order.
Note 6) Piping adapter, pressure switch with piping adapter, and cross interface need to be
ordered separately.
Note 7) The bracket position varies depending on the T-interface mounting.
Refer to the table on page 14-2-30 for standard bracket position.
Note 8) With this combination, requlators and filter requlators will be With back flow function type.
For safety, check that the ezhausted and is atmospheric pressure by pressure gauge.
14-2-32
F.R.L. Unit Series AC
How to Order
AC 30 A F 03 DE KV 12R
Option
F.R.L. unit Symbol Description Applicable model
1 (11) 0.02 to 0.2 MPa setting AC10 to 60
Body size
2 Metal bowl AC10 to 60
10 20 25 30 40 50 55 60
3 Lubricator with drain cock AC10 to 60
6 Nylon bowl AC10 to 60
F.R.L.
8 Metal bowl with level gauge AC25 to 60
C With bowl guard AC25 to 60
AV
J (12) Drain guide 1/4 AC10 to 60
Model combination
N Non-relieving type AC10 to 60
Combination AU
Symbol Filter Mist R Flow direction: Right Left AC10 to 60
Air filter Regulator Lubricator regulator separator
Nil (1) (2) (3) W Drain cock with barb fitting:
6 x 4 nylon tubing
AC25 to 60 AF
A (2) (1)
(13)
B (1) (2) Z
Name plate, caution plate for bowl, and
pressure gauge in imperial units (PSI, F)
AC10 to 60 AR
C (1) (3) (2)
When more than one specification is required, indicate
D (1) (2) in ascending alphanumeric order.
IR
Note 1) The number inside ( ) indicates the Note 11) The only difference from the standard
combination order counted from the specifications is the adjusting spring for VEX
inlet side. the regulator. It does not restrict the
setting of 0.2 MPa or more.
Note 12) Without a valve function. AMR
Note 13) For thread types M5 and NPT.
This product is for overseas use only
Thread type according to the new Measurement Law.
ITV
(The SI unit type is provided for use in
Metric system thread (M5)
Nil Japan.) IC
Rc Pressure switch comes with a dual unit
N (2) NPT scale in SI (MPa) and imperial (PSI)
units. VBA
F (3) G Attachment
Note 2) Drain guide is NPT 1/4 (applicable to AC25 Port size for
to 60), and the exhaust port for auto-drain Symbol Description Attachment
mounting position
Applicable
model
intermediate
air release
VE
comes with 3/8" One-touch fitting Nil None
(applicable to AC25 to 60).
AF + AR + [K] + AL AC20 to 40 AC20: 1/8 VY1
Note 3) Drain guide is G 1/4 (applicable to AC25 to AC25: 1/4
60). K Check valve
AC30: 1/4
AW + [K] + AL AC20A to 40A AC40: 3/8 G
AF + AR + [S] + AL AC20 to 60
Port size
AW + [S] + AL AC20A to 40A PPA
Port Body size Pressure
Symbol size S AF + [S] + AR AC20B to 60B
switch
10 20 25 30 40 50 55 60
AF + AFM + [S] + AR AC20C to 40C AL
M5 M5
AW + [S] + AFM AC20D to 40D
01 1/8
AC10: M5 x 0.8
02 1/4 AF + [T] + AR + AL AC10 to 60AC20: 1/8
03 3/8 AC25: 1/4
T T-interface AC30: 1/4
04 AF + [T] + AR AC10B to 60B AC40: 3/8
1/2
AC50: 3/8
06 3/4
AF + AFM + [T] + AR AC20C to 40C AC55: 1/2
10 1 AC60: 1/2
AF + AR + AL + [V] AC20 to 50
AW + AL + [V] AC20A to 40A
Residual
V pressure relief AF + AR + [V] AC20B to 50B
3 port valve
Accessory AF + AFM + AR + [V] AC20C to 40C
Symbol Description Applicable model AW + AFM + [V] AC20D to 40D
Nil [V] + AF + ARK AC20B to 50B
Residual
C Float type auto-drain (N.C.) (4) AC10 to 60 V1 pressure relief [V] + AF + AFM + ARK AC20C to 40C
3 port valve
D Float type auto-drain (N.O.) (4) AC25 to 60 [V] + AWK + AFM AC20D to 40D
E With square embedded type pressure gauge (With limit indicator) AC20 to 60 Note 6) When more than one attachment is required, order in
With round pressure gauge (Without limit indicator)
alphabetical order.
(5) AC10
G Note 7) Piping adapter, pressure switch with piping adapter,
With round pressure gauge (With limit indicator) AC20 to 60 and cross interface need to be ordered separately.
Note 4) Applicable tubing O.D for auto-drain connection should be Note 8) Please contact SMC when using a pressure switch
3/8" in case NPT thread port is chosen. and T-interface together for ACB.
Note 5) Mounting thread for pressure gauge: Note 9) The bracket position varies depending on the T-
1/16 for AC10; 1/8 for AC20 to 30; 1/4 for AC40 to 60 interface or pressure switch mounting. Refer to the
Pressure gauge is not mounted and is supplied loose at the table on page 14-2-30 for standard bracket position.
time of shipment. Note 10) With this combination, regulators and filter regulators
will be with back flow function type.
For safety, check that the outlet pressure is exhausted
and is atmospheric pressure by pressure gauge.
14-2-9
Series AC
Accessory/Optional Specifications Combination
: Combination available : Combination not available : Varies depending on the model : Available only with NPT thread
F.R.L. unit applicable model
Symbol
Combination Accessory Optional specifications
Accessory/ AC10 AC20 AC20B AC25B AC30 AC30A AC30B AC30C AC30D
AC10B AC20C AC25 to to
Optional specifications C D E G 1 2 3 6 8 C J N R WZ AC10A AC20A AC20D AC25C AC60 AC40A AC60B AC40C AC40D
Nylon bowl -6
Metal bowl with level gauge -8
Attachment
Port size Function
M5 x 0.8 P. 14-2-24
T-interface 1/8, 1/4, 3/8, 1/2
Redirects the air flow.
Check valve 1/8, 1/4, 3/8 Prevents back flow from lubricator. P. 14-2-26
M5 x 0.8 P. 14-2-27
Cross interface 1/8, 1/4, 3/8, 1/2
Allows piping in all 4 directions.
Residual pressure relief 1/8, 1/4, 3/8, 1/2, 3/4, 1 Releases residual pressure in lines. P. 14-2-28
3 port valve
14-2-10
F.R.L. Unit Air Filter + Mist Separator + Regulator
JIS Symbol
(5) 02
Residual pressure relief 3 port valve VHS20- 01
02 VHS30- 02
03 VHS30- 02
03 VHS40- 03
04
VHS40-06
02
01 02 02 03
(5)
Piping adapter E200- 02
03
E300- 03
04
E300- 03
04
E400- 04 E500-06
06
(5) 02
01 02 02 03
Pressure switch with piping adapter IS1000E-20 02 IS1000E-30 03 IS1000E-30 03 IS1000E-40 04
03 04 04 06
01 01 01 02
Cross interface (5)
Y24- 02 Y34- 02 Y34- 02 Y44- 03 Y54- 03
04
Note 1) in part number for the round pressure gauge indicates a type of connection thread. No indication is necessary for R; however, indicate N
for NPT.
Please contact SMC regarding the connection thread NPT and pressure gauge supply for PSI unit specifications.
Note 2) Includes one O-ring and 2 mounting screws.
Note 3) Minimum operating pressure: N.O. type0.1 MPa; N.C. type0.1 MPa (AD27), 0.15 MPa (AD37/47).
Note 4) For F.R.L. units, port sizes not in ( ) are for standard application.
Note 5) Separate interfaces are required for modular unit.
Note 6) When N is specified in the end of part number of auto-drain, applicable tubing O.D should be 3/8".
14-2-20
F.R.L. Unit Series AC20C to 40C
Dimensions
AC20C A Pressure gauge port size
Q G
E F
L T
P
C
H
IN OUT
H
L
J
Pressure gauge
B
(Option)
F.R.L.
K Square embedded type M
pressure gauge (Option)
Port size
AV
Min. clearance N AU
Drain Drain
D
for maintenance
Air filter Mist separator Regulator AF
AC25C/30C/40C AR
A Q G
E F
L
Pressure gauge port size T IR
P
VEX
H
C
IN OUT
AMR
H
L
(Option)
K
Square embedded type
M IC
pressure gauge (Option)
VBA
Port size
VE
N
Drain Drain Min. clearance
VY1
D
for maintenance
Air filter Mist separator Regulator
G
Applicable model AC20C AC25C, AC30C, AC40C, AC40C-06
With auto-drain (N.C.) Metal bowl With auto-drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting PPA
AL
Optional
B
B
B
B
B
specifications
B
N.O.: Black
B
O S N.C.: Gray O
S
M5 x 0.8 10 One-touch 1/4 Barb fitting
fitting Width across flats 17 Applicable tubing: T0604
(mm)
Standard specifications Accessory specifications
Bracket mounting size With
Model Port size With pressure gauge auto drain
A B C D
E F G H J K L L M N P Q T U B
AC20C 1/8, 1/4 126 114 26.5 45 41.5 43 30 24 33 12 5.5 5.5 3.2 50 2.5 65 29.5 2 (1) 132
AC25C 1/4, 3/8 167 143 28 50 55 57 41 35 14 7 7 4 71 13 64 28.5 0 184
AC30C 1/4, 3/8 167 146 31 50 55 57 41 35 14 7 7 4 71 10 66 30.5 3.5 187
AC40C 1/4, 3/8, 1/2 220 183 36 75 72.5 75 50 40 18 9 9 4 88 12 74 35 3.5 222
AC40C-06 3/4 235 185 36 75 77.5 80 50 40 18 9 9 4.6 88 12 74 35 3 224
Optional specifications ( 2) Note 1) For AC20 only, the position of the pressure gauge is
above the center of the piping.
Model With barb fitting With drain guide Metal bowl Metal bowl with level gauge Note 2) For optional specifications (with barb fitting, with drain
B B B B guide, with metal bowl, or with level gauge), the total
length (dimension for B) will vary.
AC20C 114
AC25C 151 150 156 176
AC30C 154 153 159 179
AC40C 191 190 196 216
AC40C-06 193 192 198 218
14-2-21
F.R.L. Unit Series AC
Attachment Specifications
Piping Adapter (E): M5 x 0.8, 1/8, 1/4, 3/8, 1/2, 3/4, 1
A piping adapter allows installation/removal of the component Port size
without removing the piping and thus makes maintenance easier.
B
Center of
F.R.L. body
A D
(mm)
Model Note) Port size A B D Applicable model
E100-M5 M5 x 0.8 10 14 14 AC10, AW10, AF10, AR10, AL10
E200-01 1/8 AC20
E200-02 1/4 30 23.5 28 AF20, AR20, AW20
E200-03 3/8 AL20, AFM20, AFD20, AWM20, AWD20
Piping adapter E300-02 1/4 AC25, AC30
E300-03 3/8 32 30 30 AF30, AR30, AW30
E300-04 1/2 AL30, AFM30, AFD30, AWM30, AWD30
E400-02 1/4 AC40
E400-03 3/8 AF40, AR40, AW40
32 36 36 AL40, AFM40, AFD40
E400-04 1/2
AWM40, AWD40
E400-06 3/4
AC40-06, AF40-06, AR40-06, AW40-06
E500-06 3/4 32 40 44
AL40-06, AFM40-06, AFD40-06
E600-06 3/4 AC50, AC55, AC60, AC50B, AC55B, AC60B
35 48 53
E600-10 1 AF50, AR50, AL50, AF60, AR60, AL60
Note) in model numbers indicates a thread type. No indication is
necessary for Rc; however, indicate N for NPT, and F for G.
Separate interfaces are required for modular unit.
Factory mounting of a piping adapter on the AC models is available as a
special order.
T-interface
Center of
F.R.L. body
A D
(mm)
Model Port size A B C D E Applicable model
Y110-M5 M5 x 0.8 11 19 12 14 8 AC10, AC10B
Y210-01 1/8 AC20, AC20B
15 42 32 28 19
Y210-02 1/4 AC20C
Y310-01 1/8 AC25, AC25B
15 53 39 30 19 AC25C, AC30
Y310-02 1/4 AC30B, AC30C
Y410-02 1/4 AC40, AC40B
19 62 44 36 24
Y410-03 3/8 AC40C
Y510-02 1/4 AC40-06, AC40B-06
19 66 46 44 24
Y510-03 3/8 AC40C-06
Caution on Mounting AC50, AC55
Y610-03 3/8
If a T-interface is used on the IN side of the lubricator, lubricant 22 81 57 53 30
AC60, AC50B
Y610-04 1/2 AC55B, AC60B
may be mixed. Use the Series AKM check valve to avoid such
possibility. Note) in model numbers indicates a thread type. No indication is
necessary for Rc; however, indicate N for NPT, and F for G.
Separate interfaces are required for modular unit.
Refer to the attachment table on Front matter 2 for standard port sizes
when using with AC.
14-2-24
Attachment Specifications Series AC
Pressure Switch with Piping Adapter (P)
Approx. 500
Pressure switch with piping adapter
A D
E 23
JIS Symbol
C
AV
B
AU
Specifications
Fluid Air AF
Proof pressure 1.0 MPa Center of
F.R.L. body
Maximum operating pressure 0.7 MPa AR
Set pressure range (mm)
(When OFF) 0.1 to 0.4 MPa
Differential 0.08 MPa
Model (1) Port size A B C D E Applicable model IR
IS1000E-2001 1/8 AC20
Ambient and fluid temperature 5 to 60C (With no freezing)
IS1000E-2002 1/4 30 68 57 28 16 AR20, AW20 VEX
IS1000E-2003 3/8 AWM20, AWD20
Switch characteristics
Contact point configuration 1a
IS1000E-3002 1/4 AC25, AC30 AMR
IS1000E-3003 3/8 32 74.5 60.5 30 13 AR25, AR30, AW30
Maximum contact point capacity 2 VA(AC), 2 W(DC)
Operating voltage: AC, DC 100 V or less
IS1000E-3004 1/2 AWM30, AWD30 ITV
IS1000E-4002 1/4
12 V to 24 VAC, DC: 50 mA
Maximum operating current 48 VAC, DC: 40 mA IS1000E-4003 3/8
32 80.5 62.5 37 12.5
AC40 (2) IC
100 VAC, DC: 20 mA IS1000E-4004 1/2 AR40, AW40
AWM40, AWD40
IS1000E-4006 3/4 VBA
Note 1) in the model numbers indicates a thread type. No indication
is necessary for Rc; however, indicate N for NPT, and F for G.
Note 2) A pressure switch cannot be mounted on AC40-06 and VE
AW40-06.
Separate interfaces are required for modular unit. VY1
The pressure switch on AC40-06 and above and AW40-06 can
be mounted by screwing IS1000-01 into the piping adapter E500-
06-X501 or E600-06-X501 to E600-06 to 10-X501 (with top- G
face thread Rc 1/8). Products with a premounted switch are
available as a special order. Please contact SMC regarding their
availability.
PPA
How to Order AL
IS1000E 30 03
Option
Pressure switch X201 Lead wire length: 3 m
with piping X202 Regulating pressure range: 0.1 to 0.6 MPa
adapter X207 MPa/PSI Dual scale
Body size X215 Lead wire length: 3 m; Regulating pressure range: 0.1 to 0.6 MPa
30 For AC25, AC30 X251 Lead wire length: 3 m; Opposite-side mounting (Left-side mounting style)
Set pressure range: 0.1 to 0.6 MPa; Opposite-side mounting
40 For AC40-02 to 04 X252 (Left-side mounting style)
Lead wire length: 3 m; Regulating pressure range: 0.1 to 0.6 MPa;
Thread type X253
Opposite-side mounting (Left-side mounting style)
Nil Rc
This product is for overseas use only according to the new Measurement Law.
N NPT (The SI unit type is provided for use in Japan.)
F G
Piping adapter port size
Port Body size
Symbol
size 20 30 40
01 1/8
02 1/4
03 3/8
04 1/2
06 3/4
14-2-25
Attachment Specifications Series AC
Pressure Switch (S)
Approx. 500
A compact integrated pressure switch can be easily installed and
facilitates the pressure detection of the line.
15 23
Pressure switch
F.R.L.
C
B
JIS Symbol
AV
AU
Center of
F.R.L. body AF
A D
Specifications (mm) AR
Fluid Air Model A B C D Applicable model
Proof pressure 1.0 MPa IS1000M-20 11 76 66 28 AC20 IR
Maximum operating pressure 0.7 MPa IS1000M-30 13 86 72 30 AC25, AC30
Set pressure range (Off) 0.1 to 0.4 MPa IS1000M-40 15 95 77 36 AC40 VEX
Differential 0.08 MPa IS1000M-50 17 99 79 44 AC40-06
Ambient and fluid temperature 5 to 60C (With no freezing) IS1000M-60 22 92.5 68.5 53 AC50, AC55B, AC60 AMR
Note) Separate interfaces are required for modular unit.
ITV
Switch Characteristics How to Order
Contact point configuration 1a IC
Maximum contact point capacity
Operating voltage: AC, DC
2 VA(AC), 2 W(DC)
100 V or less
IS1000M 30 VBA
12 V to 24 VAC, DC : 50 mA
Pressure switch Accessory
Maximum operating current 48 VAC, DC : 40 mA X201 Lead wire length: 3 m VE
100 VAC, DC : 20 mA
Body size
Regulating pressure
20 For AC20 X202 range: 0.1 to 0.6 MPa
30 For AC25, AC30 VY1
X207 MPa/PSI dual scale
40 For AC40-02 to 04 Lead wire length: 3 m;
50 For AC40-06 X215 Regulating pressure
G
60 For AC50, AC55, AC60 range: 0.1 to 0.6 MPa
This product is for overseas use PPA
only according to the new
Measurement Law. (The SI unit
type is provided for use in Japan.)
AL
Cross Interface (C): M5 x 0.8, 1/8, 1/4, 3/8, 1/2
Center of
Pipings are possible in all 4 directions. F.R.L. body Port size
E
IN/OUT ports are not machined for threads. Please
contact SMC if threaded (machined) ports are required.
F
B
C
F E E
Cross interface
E: 4-Rc
A E
F: Without thread D
(mm)
Model Port size A B C D Applicable model
Y14-M5 M5 23 16 14 25 AC10
Y24-01 1/8
40 40 22 40 AC20
Y24-02 1/4
Y34-01 1/8
49 43 28 48 AC25, AC30
Y34-02 1/4
Y44-02 1/4
Caution on Mounting 60 48 36 54 AC40
Y44-03 3/8
When mounting a cross interface directly on the IN side of the Y54-03 3/8
lubricator, be sure to use a Series AKM check valve between the 72 62 40 62 AC40-06
Y54-04 1/2
lubricator and cross interface.
Note) in the model numbers indicates a thread type. No indication is
Factory mounting of a cross interface on the AC model is necessary for Rc; however, indicate N for NPT, and F for G.
available as a special order. If threaded ports are required, they are available as a special order.
Please contact SMC.
14-2-27
Spacers and Brackets Series AC
Accessory Dimensions
Spacer (X)
D
Center of
F.R.L. body
F.R.L.
C
1
X-X AV
B
RELEASE
X
2
Y200 Y400 AU
(mm)
X
Model A B C D Applicable model
AF
Seal
Y100 6 27 15 33 AC10, AC10A, AC10B
Y200 3 35.5 18.5 48 AC20 AR
Y300 4 47 26 59 AC25, AC30
Y400 5 57 31 65 AC40 A IR
Y500 5 61 33 70 AC40-06 Spacer width
Y600 6 75.5 41 86
AC50, AC55, AC60 VEX
AC50B, AC55B, AC60B
VY1
Center of
F.R.L. body
G
C
1
X-X PPA
EE (Y100T, Y200T only)
RELEASE
X
2
AL
E
X
G
Seal
Y200T Y400T
F J
A
H K
Spacer width
D
(mm)
Model A B BB C D E EE F G G H J K Applicable model
Y100T 6 56 24.5 40.5 20 27 6.8 4.5 4.5 14 2.8 25 AC10
Y200T 3 67 29 53 24 33 12 5.5 5.5 19 3.2 30 AC20
Y300T 4 82 41 68 35 14 7 7 21 4 41 AC25, AC30
Y400T 5 96 48 81.5 40 18 9 9 26 4 50 AC40
Y500T 5 96 48 86 40 18 9 9 27 4.6 50 AC40-06
Y600T 6 120 60 112 50 20 11 11 31 6.4 70 AC50, AC55, AC60, AC50B, AC55B, AC60B
Replacement Parts
Part no.
Description Material
Y100T Y200T Y300T Y400T Y500T Y600T
Seal HNBR (2) Y100P-060AS (1) Y200P-060S Y300P-060S Y400P-060S Y500P-060S Y600P-060S
Note 1) Y-100T comes with 2 O-rings.
Note 2) NBR seal is used for Y100T spacer because of no direct contact with fluid.
14-2-29
Series AC
Mounting Position for Spacer with Bracket
Bracket
Pressure switch: S Residual pressure
T-interface: T Check valve: K relief 3 port valve: V
SUP.
SUP
A
A
IN OUT IN OUT
A
A
Bracket
L1 L2 L3 L4 L1
(mm)
Attachment K S T V KS KT KV KST
Model L1 L2 L3 L1 L2 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L4 L1 L2 L3
AC10 28 48
AC20 41.5 43 43 41.5 43 41.5 61 41.5 43 43 41.5 43 57 41.5 61 43 41.5 43 43 43 41.5 61 57
AC25 55 57 57 55 57 55 76 55 57 57 55 57 74 55 76 57 55 57 57 57 55 76 74
AC30 55 57 57 55 57 55 76 55 57 57 55 57 74 55 76 57 55 57 57 57 55 76 74
AC40 72.5 75 75 72.5 75 72.5 99 72.5 75 75 72.5 75 95 72.5 99 75 72.5 75 75 75 72.5 99 95
AC40-06 77.5 80 77.5 104 77.5 80 80
AC50 93 96 93 124 93 96 96
AC55 98 96 98 124
AC60 98 101 98 129
Attachment KSV KTV KSTV ST SV STV TV
Model L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2 L3
AC10
AC20 41.5 43 57 43 41.5 61 43 43 41.5 61 57 43 41.5 61 41.5 43 57 41.5 61 57 41.5 61 43
AC25 55 57 74 57 55 76 57 57 55 76 74 57 55 76 55 57 74 55 76 74 55 76 57
AC30 55 57 74 57 55 76 57 57 55 76 74 57 55 76 55 57 74 55 76 74 55 76 57
AC40 72.5 75 95 75 72.5 99 75 75 72.5 99 95 75 72.5 99 72.5 75 95 72.5 99 95 72.5 99 75
AC40-06 77.5 104 77.5 80 102 77.5 104 102 77.5 104 80
AC50 93 124 93 96 124 93 124 124 93 124 96
AC55 98 124
AC60 98 129
Attachment
K S V KS KV KSV SV
Model L1 L2 L1 L1 L2 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2
AC20A 41.5 43 41.5 41.5 43 41.5 57 41.5 43 43 41.5 57 43 41.5 57
AC30A 55 57 55 55 57 55 74 55 57 57 55 74 57 55 74
AC40A 72.5 75 72.5 72.5 75 72.5 95 72.5 75 75 72.5 95 75 72.5 95
AC40A-06 77.5 77.5 80 77.5 102
Attachment
S T V SV TV
Model L1 L1 L1 L2 L1 L2 L1 L2
AC10B 28
AC20B 41.5 41.5 41.5 43 41.5 57 41.5 61
AC25B 55 55 55 57 55 74 55 76
AC30B 55 55 55 57 55 74 55 76
AC40B 72.5 72.5 72.5 75 72.5 95 72.5 99
AC40B-06 77.5 77.5 77.5 80 77.5 102 77.5 104
AC50B 93 93 93 96 93 124 93 124
AC55B 98 98
AC60B 98 98
Attachment
S T V SV TV
Model L1 L2 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2 L3
AC20C 41.5 43 41.5 43 41.5 43 43 41.5 43 57 41.5 43 61
AC25C 55 57 55 57 55 57 57 55 57 74 55 57 76
AC30C 55 57 55 57 55 57 57 55 57 74 55 57 76
AC40C 72.5 75 72.5 75 72.5 75 75 72.5 75 95 72.5 75 99
AC40C-06 77.5 80 77.5 80 77.5 80 80 77.5 80 102 77.5 80 104
Attachment
S V SV L1: Dimensions from the end of the IN side to the center of the mounting hole for the first bracket.
Model L1 L1 L2 L1 L2 L2: Mounting hole pitch between the first and the second bracket.
AC20D 41.5 41.5 43 41.5 57 L3: Mounting hole pitch between the second and the third bracket.
AC30D 55 55 57 55 74 L4: Mounting hole pitch between the third and the fourth bracket.
AC40D 72.5 72.5 75 72.5 95 Refer to dimensions pages for dimension A from the center of the piping and the mounting hole.
AC40D-06 77.5 77.5 80 77.5 102
14-2-30
F.R.L. Unit Series AC20 to 60
Made to Order Specifications:
Please contact SMC for detailed dimensions, specifications, and lead times.
F.R.L.
AV
AU
AF
AR
IR
Specifications VEX
Part no. -X465
Model ISE30---L AMR
Set pressure range 0.1 to 1 MPa
Pressure
Set/Display resolution 0.001 MPa ITV
switch
Power supply voltage 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With reverse connection protection)
Current consumption 45 mA or less (70 mA or less during current output)
IC
Pressure gauge port size: Rc 1/8
VBA
Applicable Model VE
Model AC20 AC25 AC30 AC40 AC40-06 AC50 AC55 AC60
14-2-31
Series AC
How to Order
AC 30 A F 03 D KV 12R X465 A
Switch specifications
F.R.L. unit
Symbol Output specifications
Body size A NPN output
20 25 30 40 50 55 60 B PNP output
C 1 to 5 V output
Model combination D 4 to 20 mA output
Combination With digital pressure switch
Symbol Filter Mist
Air filter Regulator Lubricator Regulator Separator (Series ISE30) (12)
Nil (1) (2) (3) Note 12) Digital pressure switch is not
A (2) (1) mounted and is supplied
loose at the time of
B (1) (2) Description shipment.
C (1) (3) (2) Symbol Description Applicable model
D (1) (2) 1 (9) 0.02 to 0.2 MPa setting AC20 to 60
Note 1) The circled numbers indicate the 2 Metal bowl AC20 to 60
order in which the units are
assembled. 3 Lubricator with drain cock AC20 to 60
6 Nylon bowl (Including sight dome) AC20 to 60
Thread type
8 Metal bowl with level gauge AC25 to 60
Nil Rc C With bowl guard AC20
N (2) NPT J (10) Drain guide 1/4 AC25 to 60
F (3) G N Non-relieving type AC20 to 60
Note 2) Drain guide is NPT 1/4 (applicable R Flow direction: Right Left AC20 to 60
to AC25 to 60), and the exhaust
port for auto-drain comes with 3/8" Drain cock with barb fitting:
W AC25 to 60
One-touch fitting (applicable to 6 x 4 nylon tubing
AC25 to 60).
Name plate and caution plate for
Note 3) Drain guide is G 1/4 (applicable to Z (11) bowl in imperial units (PSI, F) AC20 to 60
AC25 to 60).
Port size When more than one specification is required, indicate
Port Body size in ascending alphanumeric order.
Symbol
size 20 25 30 40 50 55 60 Note 9) The only difference from the standard
01 1/8 specifications is the adjusting spring for
the regulator. It does not restrict the
02 1/4
setting of 0.2 MPa or more.
03 3/8 Note 10) Without a valve function.
04 1/2 Note 11) For thread type NPT.
06 3/4 This product is for overseas use only
10 1 according to the new Measurement Law.
(The SI unit type is provided for use in
Japan.)
Accessory Attachment
Symbol Description Applicable model Attachment Port size for
Symbol Description Applicable model intermediate
Nil mounting position air release
C With float type auto-drain (N.C.) (4) AC20 to 60 Nil None
D With float type auto-drain (N.O.) (4) AC25 to 60 AF + AR + [K] + AL AC20: 1/8
AC20 to 40
K Check valve AC25: 1/4
Note 4) Applicable tubing O.D for auto drain connection should be AW + [K] + AL AC20A to 40A AC30: 1/4
AC40: 3/8
3/8" in case NPT thread port is chosen.
AC20: 1/8
AF + [T] + AR + AL AC20 to 60 AC25: 1/4
AC30: 1/4
T T-interface AF + [T] + AR AC20B to 60B AC40: 3/8
AC50: 3/8
AF + AFM + [T] + AR AC20C to 40C AC55: 1/2
AC60: 1/2
AF + AR + AL + [V] AC20 to 50
Note 13) Please consult with SMC for detailed AW + AL + [V] AC20A to 40A
dimensions and available attachments and Residual
V pressure relief
AF + AR + [V] AC20B to 50B
options.
Note 14) Refer to SMC catalog CAT.ES100-42 for 3 port valve AF + AFM + AR + [V] AC20C to 40C
detailed specifications and instructions of AW + AFM + [V] AC20D to 40D
digital pressure switch. [V] + AF + ARK AC20B to 50B
Residual
V1 (8) pressure relief [V] + AF + AFM + ARK AC20C to 40C
3 port valve
[V] + AWK+ AFM AC20D to 40D
Note 5) When more than one attachment is required, order in alphabetical order.
Note 6) Piping adapter, pressure switch with piping adapter, and cross interface need to be
ordered separately.
Note 7) The bracket position varies depending on the T-interface mounting.
Refer to the table on page 14-2-30 for standard bracket position.
Note 8) With this combination, requlators and filter requlators will be With back flow function type.
For safety, check that the ezhausted and is atmospheric pressure by pressure gauge.
14-2-32
F.R.L. Unit Series AC
How to Order
AC 30 A F 03 DE KV 12R
Option
F.R.L. unit Symbol Description Applicable model
1 (11) 0.02 to 0.2 MPa setting AC10 to 60
Body size
2 Metal bowl AC10 to 60
10 20 25 30 40 50 55 60
3 Lubricator with drain cock AC10 to 60
6 Nylon bowl AC10 to 60
F.R.L.
8 Metal bowl with level gauge AC25 to 60
C With bowl guard AC25 to 60
AV
J (12) Drain guide 1/4 AC10 to 60
Model combination
N Non-relieving type AC10 to 60
Combination AU
Symbol Filter Mist R Flow direction: Right Left AC10 to 60
Air filter Regulator Lubricator regulator separator
Nil (1) (2) (3) W Drain cock with barb fitting:
6 x 4 nylon tubing
AC25 to 60 AF
A (2) (1)
(13)
B (1) (2) Z
Name plate, caution plate for bowl, and
pressure gauge in imperial units (PSI, F)
AC10 to 60 AR
C (1) (3) (2)
When more than one specification is required, indicate
D (1) (2) in ascending alphanumeric order.
IR
Note 1) The number inside ( ) indicates the Note 11) The only difference from the standard
combination order counted from the specifications is the adjusting spring for VEX
inlet side. the regulator. It does not restrict the
setting of 0.2 MPa or more.
Note 12) Without a valve function. AMR
Note 13) For thread types M5 and NPT.
This product is for overseas use only
Thread type according to the new Measurement Law.
ITV
(The SI unit type is provided for use in
Metric system thread (M5)
Nil Japan.) IC
Rc Pressure switch comes with a dual unit
N (2) NPT scale in SI (MPa) and imperial (PSI)
units. VBA
F (3) G Attachment
Note 2) Drain guide is NPT 1/4 (applicable to AC25 Port size for
to 60), and the exhaust port for auto-drain Symbol Description Attachment
mounting position
Applicable
model
intermediate
air release
VE
comes with 3/8" One-touch fitting Nil None
(applicable to AC25 to 60).
AF + AR + [K] + AL AC20 to 40 AC20: 1/8 VY1
Note 3) Drain guide is G 1/4 (applicable to AC25 to AC25: 1/4
60). K Check valve
AC30: 1/4
AW + [K] + AL AC20A to 40A AC40: 3/8 G
AF + AR + [S] + AL AC20 to 60
Port size
AW + [S] + AL AC20A to 40A PPA
Port Body size Pressure
Symbol size S AF + [S] + AR AC20B to 60B
switch
10 20 25 30 40 50 55 60
AF + AFM + [S] + AR AC20C to 40C AL
M5 M5
AW + [S] + AFM AC20D to 40D
01 1/8
AC10: M5 x 0.8
02 1/4 AF + [T] + AR + AL AC10 to 60AC20: 1/8
03 3/8 AC25: 1/4
T T-interface AC30: 1/4
04 AF + [T] + AR AC10B to 60B AC40: 3/8
1/2
AC50: 3/8
06 3/4
AF + AFM + [T] + AR AC20C to 40C AC55: 1/2
10 1 AC60: 1/2
AF + AR + AL + [V] AC20 to 50
AW + AL + [V] AC20A to 40A
Residual
V pressure relief AF + AR + [V] AC20B to 50B
3 port valve
Accessory AF + AFM + AR + [V] AC20C to 40C
Symbol Description Applicable model AW + AFM + [V] AC20D to 40D
Nil [V] + AF + ARK AC20B to 50B
Residual
C Float type auto-drain (N.C.) (4) AC10 to 60 V1 pressure relief [V] + AF + AFM + ARK AC20C to 40C
3 port valve
D Float type auto-drain (N.O.) (4) AC25 to 60 [V] + AWK + AFM AC20D to 40D
E With square embedded type pressure gauge (With limit indicator) AC20 to 60 Note 6) When more than one attachment is required, order in
With round pressure gauge (Without limit indicator)
alphabetical order.
(5) AC10
G Note 7) Piping adapter, pressure switch with piping adapter,
With round pressure gauge (With limit indicator) AC20 to 60 and cross interface need to be ordered separately.
Note 4) Applicable tubing O.D for auto-drain connection should be Note 8) Please contact SMC when using a pressure switch
3/8" in case NPT thread port is chosen. and T-interface together for ACB.
Note 5) Mounting thread for pressure gauge: Note 9) The bracket position varies depending on the T-
1/16 for AC10; 1/8 for AC20 to 30; 1/4 for AC40 to 60 interface or pressure switch mounting. Refer to the
Pressure gauge is not mounted and is supplied loose at the table on page 14-2-30 for standard bracket position.
time of shipment. Note 10) With this combination, regulators and filter regulators
will be with back flow function type.
For safety, check that the outlet pressure is exhausted
and is atmospheric pressure by pressure gauge.
14-2-9
Series AC
Accessory/Optional Specifications Combination
: Combination available : Combination not available : Varies depending on the model : Available only with NPT thread
F.R.L. unit applicable model
Symbol
Combination Accessory Optional specifications
Accessory/ AC10 AC20 AC20B AC25B AC30 AC30A AC30B AC30C AC30D
AC10B AC20C AC25 to to
Optional specifications C D E G 1 2 3 6 8 C J N R WZ AC10A AC20A AC20D AC25C AC60 AC40A AC60B AC40C AC40D
Nylon bowl -6
Metal bowl with level gauge -8
Attachment
Port size Function
M5 x 0.8 P. 14-2-24
T-interface 1/8, 1/4, 3/8, 1/2
Redirects the air flow.
Check valve 1/8, 1/4, 3/8 Prevents back flow from lubricator. P. 14-2-26
M5 x 0.8 P. 14-2-27
Cross interface 1/8, 1/4, 3/8, 1/2
Allows piping in all 4 directions.
Residual pressure relief 1/8, 1/4, 3/8, 1/2, 3/4, 1 Releases residual pressure in lines. P. 14-2-28
3 port valve
14-2-10
F.R.L. Unit Filter Regulator + Mist Separator
JIS Symbol
AC20D AC40D
Standard Specifications
Model AC20D AC30D AC40D AC40D-06
02
Residual pressure relief 3 port valve (5) VHS20- 01
02 VHS30- 02
03 VHS40- 03
04
VHS40-06
02
01 02
Piping adapter (5)
E200- 02
03
E300- 03
04
E400- 03
04 E500-06
06
02
(5) 01 02 03
Pressure switch with piping adapter IS1000E-20 02 IS1000E-30 03 IS1000E-40 04
03 04 06
01 01 02
Cross interface (5)
Y24- 02 Y34- 02 Y44- 03 Y54- 03
04
Note 1) in part number for the round pressure gauge indicates a type of connection thread. No indication is necessary for R; however, indicate N
for NPT.
Please contact SMC regarding the connection thread NPT and pressure gauge supply for PSI unit specifications.
Note 2) Includes one O-ring and 2 mounting screws.
Note 3) Minimum operating pressure: N.O. type0.1 MPa; N.C. type0.1 MPa (AD27), 0.15 MPa (AD37/47).
Note 4) For F.R.L. units, port sizes not in ( ) are for standard application.
Note 5) Separate interfaces are required for modular unit.
Note 6) When N is specified in the end of part number of auto-drain, applicable tubing O.D should be 3/8".
14-2-22
F.R.L. Unit Series AC20D to 40D
Dimensions
AC20D A N F
E P
G
IN OUT
Q
B
F.R.L.
G
H
OUT
Pressure gauge
Pressure gauge (Option)
port size
J Square embedded type L AV
pressure gauge (Option)
Port size
AU
Drain Drain M
Min. clearance AF
D
Filter Mist for maintenance
regulator separator
AR
A N F IR
AC30D/40D E P
VEX
AMR
K
C
ITV
G
IN OUT Q
IC
B
G
Pressure gauge
K
OUT
for maintenance
Filter Mist
regulator separator
PPA
Applicable model AC20D AC30D, AC40D, AC40D-06
With auto-drain (N.C.) Metal bowl With auto-drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting AL
Optional
B
B
B
B
specifications
B
N.O.: Black
B
O S N.C.: Gray O
S
M5 x 0.8 10 One-touch 1/4 Barb fitting
fitting Width across flats 17 Applicable tubing: T0604
(mm)
Standard specifications Accessory specifications
With
Model Port size Bracket mounting size With pressure gauge auto-drain
A B C D
E F G H J K K L M N P Q B
AC20D 1/8, 1/4 83 160 73 45 41.5 30 24 33 12 5.5 5.5 3.2 50 63 27 5 177
AC30D 1/4, 3/8 110 201 86 55 55 41 35 14 7 7 4 71 66 30.5 3.5 242
AC40D 1/4, 3/8, 1/2 145 239 92 80 72.5 50 40 18 9 9 4 88 76 38.5 1.5 278
AC40D-06 3/4 155 242 93 80 77.5 50 40 18 9 9 4.6 88 76 38.5 1.2 278
Optional specifications Note) Note) For optional specifications (with barb fitting, with drain guide, with
Model With barb fitting With drain guide Metal bowl Metal bowl with level gauge metal bowl, or with level gauge), the total length (dimension for
B) will vary.
B B B B
AC20D 160
AC30D 209 208 214 234
AC40D 247 246 251 272
AC40D-06 250 249 255 275
14-2-23
F.R.L. Unit Series AC
Attachment Specifications
Piping Adapter (E): M5 x 0.8, 1/8, 1/4, 3/8, 1/2, 3/4, 1
A piping adapter allows installation/removal of the component Port size
without removing the piping and thus makes maintenance easier.
B
Center of
F.R.L. body
A D
(mm)
Model Note) Port size A B D Applicable model
E100-M5 M5 x 0.8 10 14 14 AC10, AW10, AF10, AR10, AL10
E200-01 1/8 AC20
E200-02 1/4 30 23.5 28 AF20, AR20, AW20
E200-03 3/8 AL20, AFM20, AFD20, AWM20, AWD20
Piping adapter E300-02 1/4 AC25, AC30
E300-03 3/8 32 30 30 AF30, AR30, AW30
E300-04 1/2 AL30, AFM30, AFD30, AWM30, AWD30
E400-02 1/4 AC40
E400-03 3/8 AF40, AR40, AW40
32 36 36 AL40, AFM40, AFD40
E400-04 1/2
AWM40, AWD40
E400-06 3/4
AC40-06, AF40-06, AR40-06, AW40-06
E500-06 3/4 32 40 44
AL40-06, AFM40-06, AFD40-06
E600-06 3/4 AC50, AC55, AC60, AC50B, AC55B, AC60B
35 48 53
E600-10 1 AF50, AR50, AL50, AF60, AR60, AL60
Note) in model numbers indicates a thread type. No indication is
necessary for Rc; however, indicate N for NPT, and F for G.
Separate interfaces are required for modular unit.
Factory mounting of a piping adapter on the AC models is available as a
special order.
T-interface
Center of
F.R.L. body
A D
(mm)
Model Port size A B C D E Applicable model
Y110-M5 M5 x 0.8 11 19 12 14 8 AC10, AC10B
Y210-01 1/8 AC20, AC20B
15 42 32 28 19
Y210-02 1/4 AC20C
Y310-01 1/8 AC25, AC25B
15 53 39 30 19 AC25C, AC30
Y310-02 1/4 AC30B, AC30C
Y410-02 1/4 AC40, AC40B
19 62 44 36 24
Y410-03 3/8 AC40C
Y510-02 1/4 AC40-06, AC40B-06
19 66 46 44 24
Y510-03 3/8 AC40C-06
Caution on Mounting AC50, AC55
Y610-03 3/8
If a T-interface is used on the IN side of the lubricator, lubricant 22 81 57 53 30
AC60, AC50B
Y610-04 1/2 AC55B, AC60B
may be mixed. Use the Series AKM check valve to avoid such
possibility. Note) in model numbers indicates a thread type. No indication is
necessary for Rc; however, indicate N for NPT, and F for G.
Separate interfaces are required for modular unit.
Refer to the attachment table on Front matter 2 for standard port sizes
when using with AC.
14-2-24
Attachment Specifications Series AC
Pressure Switch with Piping Adapter (P)
Approx. 500
Pressure switch with piping adapter
A D
E 23
JIS Symbol
C
AV
B
AU
Specifications
Fluid Air AF
Proof pressure 1.0 MPa Center of
F.R.L. body
Maximum operating pressure 0.7 MPa AR
Set pressure range (mm)
(When OFF) 0.1 to 0.4 MPa
Differential 0.08 MPa
Model (1) Port size A B C D E Applicable model IR
IS1000E-2001 1/8 AC20
Ambient and fluid temperature 5 to 60C (With no freezing)
IS1000E-2002 1/4 30 68 57 28 16 AR20, AW20 VEX
IS1000E-2003 3/8 AWM20, AWD20
Switch characteristics
Contact point configuration 1a
IS1000E-3002 1/4 AC25, AC30 AMR
IS1000E-3003 3/8 32 74.5 60.5 30 13 AR25, AR30, AW30
Maximum contact point capacity 2 VA(AC), 2 W(DC)
Operating voltage: AC, DC 100 V or less
IS1000E-3004 1/2 AWM30, AWD30 ITV
IS1000E-4002 1/4
12 V to 24 VAC, DC: 50 mA
Maximum operating current 48 VAC, DC: 40 mA IS1000E-4003 3/8
32 80.5 62.5 37 12.5
AC40 (2) IC
100 VAC, DC: 20 mA IS1000E-4004 1/2 AR40, AW40
AWM40, AWD40
IS1000E-4006 3/4 VBA
Note 1) in the model numbers indicates a thread type. No indication
is necessary for Rc; however, indicate N for NPT, and F for G.
Note 2) A pressure switch cannot be mounted on AC40-06 and VE
AW40-06.
Separate interfaces are required for modular unit. VY1
The pressure switch on AC40-06 and above and AW40-06 can
be mounted by screwing IS1000-01 into the piping adapter E500-
06-X501 or E600-06-X501 to E600-06 to 10-X501 (with top- G
face thread Rc 1/8). Products with a premounted switch are
available as a special order. Please contact SMC regarding their
availability.
PPA
How to Order AL
IS1000E 30 03
Option
Pressure switch X201 Lead wire length: 3 m
with piping X202 Regulating pressure range: 0.1 to 0.6 MPa
adapter X207 MPa/PSI Dual scale
Body size X215 Lead wire length: 3 m; Regulating pressure range: 0.1 to 0.6 MPa
30 For AC25, AC30 X251 Lead wire length: 3 m; Opposite-side mounting (Left-side mounting style)
Set pressure range: 0.1 to 0.6 MPa; Opposite-side mounting
40 For AC40-02 to 04 X252 (Left-side mounting style)
Lead wire length: 3 m; Regulating pressure range: 0.1 to 0.6 MPa;
Thread type X253
Opposite-side mounting (Left-side mounting style)
Nil Rc
This product is for overseas use only according to the new Measurement Law.
N NPT (The SI unit type is provided for use in Japan.)
F G
Piping adapter port size
Port Body size
Symbol
size 20 30 40
01 1/8
02 1/4
03 3/8
04 1/2
06 3/4
14-2-25
Attachment Specifications Series AC
Pressure Switch (S)
Approx. 500
A compact integrated pressure switch can be easily installed and
facilitates the pressure detection of the line.
15 23
Pressure switch
F.R.L.
C
B
JIS Symbol
AV
AU
Center of
F.R.L. body AF
A D
Specifications (mm) AR
Fluid Air Model A B C D Applicable model
Proof pressure 1.0 MPa IS1000M-20 11 76 66 28 AC20 IR
Maximum operating pressure 0.7 MPa IS1000M-30 13 86 72 30 AC25, AC30
Set pressure range (Off) 0.1 to 0.4 MPa IS1000M-40 15 95 77 36 AC40 VEX
Differential 0.08 MPa IS1000M-50 17 99 79 44 AC40-06
Ambient and fluid temperature 5 to 60C (With no freezing) IS1000M-60 22 92.5 68.5 53 AC50, AC55B, AC60 AMR
Note) Separate interfaces are required for modular unit.
ITV
Switch Characteristics How to Order
Contact point configuration 1a IC
Maximum contact point capacity
Operating voltage: AC, DC
2 VA(AC), 2 W(DC)
100 V or less
IS1000M 30 VBA
12 V to 24 VAC, DC : 50 mA
Pressure switch Accessory
Maximum operating current 48 VAC, DC : 40 mA X201 Lead wire length: 3 m VE
100 VAC, DC : 20 mA
Body size
Regulating pressure
20 For AC20 X202 range: 0.1 to 0.6 MPa
30 For AC25, AC30 VY1
X207 MPa/PSI dual scale
40 For AC40-02 to 04 Lead wire length: 3 m;
50 For AC40-06 X215 Regulating pressure
G
60 For AC50, AC55, AC60 range: 0.1 to 0.6 MPa
This product is for overseas use PPA
only according to the new
Measurement Law. (The SI unit
type is provided for use in Japan.)
AL
Cross Interface (C): M5 x 0.8, 1/8, 1/4, 3/8, 1/2
Center of
Pipings are possible in all 4 directions. F.R.L. body Port size
E
IN/OUT ports are not machined for threads. Please
contact SMC if threaded (machined) ports are required.
F
B
C
F E E
Cross interface
E: 4-Rc
A E
F: Without thread D
(mm)
Model Port size A B C D Applicable model
Y14-M5 M5 23 16 14 25 AC10
Y24-01 1/8
40 40 22 40 AC20
Y24-02 1/4
Y34-01 1/8
49 43 28 48 AC25, AC30
Y34-02 1/4
Y44-02 1/4
Caution on Mounting 60 48 36 54 AC40
Y44-03 3/8
When mounting a cross interface directly on the IN side of the Y54-03 3/8
lubricator, be sure to use a Series AKM check valve between the 72 62 40 62 AC40-06
Y54-04 1/2
lubricator and cross interface.
Note) in the model numbers indicates a thread type. No indication is
Factory mounting of a cross interface on the AC model is necessary for Rc; however, indicate N for NPT, and F for G.
available as a special order. If threaded ports are required, they are available as a special order.
Please contact SMC.
14-2-27
Spacers and Brackets Series AC
Accessory Dimensions
Spacer (X)
D
Center of
F.R.L. body
F.R.L.
C
1
X-X AV
B
RELEASE
X
2
Y200 Y400 AU
(mm)
X
Model A B C D Applicable model
AF
Seal
Y100 6 27 15 33 AC10, AC10A, AC10B
Y200 3 35.5 18.5 48 AC20 AR
Y300 4 47 26 59 AC25, AC30
Y400 5 57 31 65 AC40 A IR
Y500 5 61 33 70 AC40-06 Spacer width
Y600 6 75.5 41 86
AC50, AC55, AC60 VEX
AC50B, AC55B, AC60B
VY1
Center of
F.R.L. body
G
C
1
X-X PPA
EE (Y100T, Y200T only)
RELEASE
X
2
AL
E
X
G
Seal
Y200T Y400T
F J
A
H K
Spacer width
D
(mm)
Model A B BB C D E EE F G G H J K Applicable model
Y100T 6 56 24.5 40.5 20 27 6.8 4.5 4.5 14 2.8 25 AC10
Y200T 3 67 29 53 24 33 12 5.5 5.5 19 3.2 30 AC20
Y300T 4 82 41 68 35 14 7 7 21 4 41 AC25, AC30
Y400T 5 96 48 81.5 40 18 9 9 26 4 50 AC40
Y500T 5 96 48 86 40 18 9 9 27 4.6 50 AC40-06
Y600T 6 120 60 112 50 20 11 11 31 6.4 70 AC50, AC55, AC60, AC50B, AC55B, AC60B
Replacement Parts
Part no.
Description Material
Y100T Y200T Y300T Y400T Y500T Y600T
Seal HNBR (2) Y100P-060AS (1) Y200P-060S Y300P-060S Y400P-060S Y500P-060S Y600P-060S
Note 1) Y-100T comes with 2 O-rings.
Note 2) NBR seal is used for Y100T spacer because of no direct contact with fluid.
14-2-29
Series AC
Mounting Position for Spacer with Bracket
Bracket
Pressure switch: S Residual pressure
T-interface: T Check valve: K relief 3 port valve: V
SUP.
SUP
A
A
IN OUT IN OUT
A
A
Bracket
L1 L2 L3 L4 L1
(mm)
Attachment K S T V KS KT KV KST
Model L1 L2 L3 L1 L2 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L4 L1 L2 L3
AC10 28 48
AC20 41.5 43 43 41.5 43 41.5 61 41.5 43 43 41.5 43 57 41.5 61 43 41.5 43 43 43 41.5 61 57
AC25 55 57 57 55 57 55 76 55 57 57 55 57 74 55 76 57 55 57 57 57 55 76 74
AC30 55 57 57 55 57 55 76 55 57 57 55 57 74 55 76 57 55 57 57 57 55 76 74
AC40 72.5 75 75 72.5 75 72.5 99 72.5 75 75 72.5 75 95 72.5 99 75 72.5 75 75 75 72.5 99 95
AC40-06 77.5 80 77.5 104 77.5 80 80
AC50 93 96 93 124 93 96 96
AC55 98 96 98 124
AC60 98 101 98 129
Attachment KSV KTV KSTV ST SV STV TV
Model L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2 L3
AC10
AC20 41.5 43 57 43 41.5 61 43 43 41.5 61 57 43 41.5 61 41.5 43 57 41.5 61 57 41.5 61 43
AC25 55 57 74 57 55 76 57 57 55 76 74 57 55 76 55 57 74 55 76 74 55 76 57
AC30 55 57 74 57 55 76 57 57 55 76 74 57 55 76 55 57 74 55 76 74 55 76 57
AC40 72.5 75 95 75 72.5 99 75 75 72.5 99 95 75 72.5 99 72.5 75 95 72.5 99 95 72.5 99 75
AC40-06 77.5 104 77.5 80 102 77.5 104 102 77.5 104 80
AC50 93 124 93 96 124 93 124 124 93 124 96
AC55 98 124
AC60 98 129
Attachment
K S V KS KV KSV SV
Model L1 L2 L1 L1 L2 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2
AC20A 41.5 43 41.5 41.5 43 41.5 57 41.5 43 43 41.5 57 43 41.5 57
AC30A 55 57 55 55 57 55 74 55 57 57 55 74 57 55 74
AC40A 72.5 75 72.5 72.5 75 72.5 95 72.5 75 75 72.5 95 75 72.5 95
AC40A-06 77.5 77.5 80 77.5 102
Attachment
S T V SV TV
Model L1 L1 L1 L2 L1 L2 L1 L2
AC10B 28
AC20B 41.5 41.5 41.5 43 41.5 57 41.5 61
AC25B 55 55 55 57 55 74 55 76
AC30B 55 55 55 57 55 74 55 76
AC40B 72.5 72.5 72.5 75 72.5 95 72.5 99
AC40B-06 77.5 77.5 77.5 80 77.5 102 77.5 104
AC50B 93 93 93 96 93 124 93 124
AC55B 98 98
AC60B 98 98
Attachment
S T V SV TV
Model L1 L2 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2 L3
AC20C 41.5 43 41.5 43 41.5 43 43 41.5 43 57 41.5 43 61
AC25C 55 57 55 57 55 57 57 55 57 74 55 57 76
AC30C 55 57 55 57 55 57 57 55 57 74 55 57 76
AC40C 72.5 75 72.5 75 72.5 75 75 72.5 75 95 72.5 75 99
AC40C-06 77.5 80 77.5 80 77.5 80 80 77.5 80 102 77.5 80 104
Attachment
S V SV L1: Dimensions from the end of the IN side to the center of the mounting hole for the first bracket.
Model L1 L1 L2 L1 L2 L2: Mounting hole pitch between the first and the second bracket.
AC20D 41.5 41.5 43 41.5 57 L3: Mounting hole pitch between the second and the third bracket.
AC30D 55 55 57 55 74 L4: Mounting hole pitch between the third and the fourth bracket.
AC40D 72.5 72.5 75 72.5 95 Refer to dimensions pages for dimension A from the center of the piping and the mounting hole.
AC40D-06 77.5 77.5 80 77.5 102
14-2-30
F.R.L. Unit Series AC20 to 60
Made to Order Specifications:
Please contact SMC for detailed dimensions, specifications, and lead times.
F.R.L.
AV
AU
AF
AR
IR
Specifications VEX
Part no. -X465
Model ISE30---L AMR
Set pressure range 0.1 to 1 MPa
Pressure
Set/Display resolution 0.001 MPa ITV
switch
Power supply voltage 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With reverse connection protection)
Current consumption 45 mA or less (70 mA or less during current output)
IC
Pressure gauge port size: Rc 1/8
VBA
Applicable Model VE
Model AC20 AC25 AC30 AC40 AC40-06 AC50 AC55 AC60
14-2-31
Series AC
How to Order
AC 30 A F 03 D KV 12R X465 A
Switch specifications
F.R.L. unit
Symbol Output specifications
Body size A NPN output
20 25 30 40 50 55 60 B PNP output
C 1 to 5 V output
Model combination D 4 to 20 mA output
Combination With digital pressure switch
Symbol Filter Mist
Air filter Regulator Lubricator Regulator Separator (Series ISE30) (12)
Nil (1) (2) (3) Note 12) Digital pressure switch is not
A (2) (1) mounted and is supplied
loose at the time of
B (1) (2) Description shipment.
C (1) (3) (2) Symbol Description Applicable model
D (1) (2) 1 (9) 0.02 to 0.2 MPa setting AC20 to 60
Note 1) The circled numbers indicate the 2 Metal bowl AC20 to 60
order in which the units are
assembled. 3 Lubricator with drain cock AC20 to 60
6 Nylon bowl (Including sight dome) AC20 to 60
Thread type
8 Metal bowl with level gauge AC25 to 60
Nil Rc C With bowl guard AC20
N (2) NPT J (10) Drain guide 1/4 AC25 to 60
F (3) G N Non-relieving type AC20 to 60
Note 2) Drain guide is NPT 1/4 (applicable R Flow direction: Right Left AC20 to 60
to AC25 to 60), and the exhaust
port for auto-drain comes with 3/8" Drain cock with barb fitting:
W AC25 to 60
One-touch fitting (applicable to 6 x 4 nylon tubing
AC25 to 60).
Name plate and caution plate for
Note 3) Drain guide is G 1/4 (applicable to Z (11) bowl in imperial units (PSI, F) AC20 to 60
AC25 to 60).
Port size When more than one specification is required, indicate
Port Body size in ascending alphanumeric order.
Symbol
size 20 25 30 40 50 55 60 Note 9) The only difference from the standard
01 1/8 specifications is the adjusting spring for
the regulator. It does not restrict the
02 1/4
setting of 0.2 MPa or more.
03 3/8 Note 10) Without a valve function.
04 1/2 Note 11) For thread type NPT.
06 3/4 This product is for overseas use only
10 1 according to the new Measurement Law.
(The SI unit type is provided for use in
Japan.)
Accessory Attachment
Symbol Description Applicable model Attachment Port size for
Symbol Description Applicable model intermediate
Nil mounting position air release
C With float type auto-drain (N.C.) (4) AC20 to 60 Nil None
D With float type auto-drain (N.O.) (4) AC25 to 60 AF + AR + [K] + AL AC20: 1/8
AC20 to 40
K Check valve AC25: 1/4
Note 4) Applicable tubing O.D for auto drain connection should be AW + [K] + AL AC20A to 40A AC30: 1/4
AC40: 3/8
3/8" in case NPT thread port is chosen.
AC20: 1/8
AF + [T] + AR + AL AC20 to 60 AC25: 1/4
AC30: 1/4
T T-interface AF + [T] + AR AC20B to 60B AC40: 3/8
AC50: 3/8
AF + AFM + [T] + AR AC20C to 40C AC55: 1/2
AC60: 1/2
AF + AR + AL + [V] AC20 to 50
Note 13) Please consult with SMC for detailed AW + AL + [V] AC20A to 40A
dimensions and available attachments and Residual
V pressure relief
AF + AR + [V] AC20B to 50B
options.
Note 14) Refer to SMC catalog CAT.ES100-42 for 3 port valve AF + AFM + AR + [V] AC20C to 40C
detailed specifications and instructions of AW + AFM + [V] AC20D to 40D
digital pressure switch. [V] + AF + ARK AC20B to 50B
Residual
V1 (8) pressure relief [V] + AF + AFM + ARK AC20C to 40C
3 port valve
[V] + AWK+ AFM AC20D to 40D
Note 5) When more than one attachment is required, order in alphabetical order.
Note 6) Piping adapter, pressure switch with piping adapter, and cross interface need to be
ordered separately.
Note 7) The bracket position varies depending on the T-interface mounting.
Refer to the table on page 14-2-30 for standard bracket position.
Note 8) With this combination, requlators and filter requlators will be With back flow function type.
For safety, check that the ezhausted and is atmospheric pressure by pressure gauge.
14-2-32
Safety Instructions
These safety instructions are intended to prevent a hazardous situation and/or
equipment damage. These instructions indicate the level of potential hazard by labels of
"Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1),
JIS B 8370 Note 2) and other safety practices.
Warning
1. The compatibility of pneumatic equipment is the responsibility of the person
who designs the pneumatic system or decides its specifications.
Since the products specified here are used in various operating conditions, their compatibility for the
specific pneumatic system must be based on specifications or after analysis and/or tests to meet your
specific requirements. The expected performance and safety assurance will be the responsibility of the
person who has determined the compatibility of the system. This person should continuously review
the suitability of all items specified, referring to the latest catalog information with a view to giving due
consideration to any possibility of equipment failure when configuring a system.
2. Only trained personnel should operate pneumatically operated machinery
and equipment.
Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of
pneumatic systems should be performed by trained and experienced operators.
3. Do not service machinery/equipment or attempt to remove components until
safety is confirmed.
1. Inspection and maintenance of machinery/equipment should only be performed once measures to
prevent falling or runaway of the driver objects have been confirmed.
2. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply
pressure for this equipment and exhaust all residual compressed air in the system.
3. Before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston
rod, etc.
4. Contact SMC if the product is to be used in any of the following conditions:
1. Conditions and environments beyond the given specifications, or if product is used outdoors.
2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles,
medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and
brake circuits in press applications, or safety equipment.
3. An application which has the possibility of having negative effects on people, property, or animals,
requiring special safety analysis.
14-21-3
Common Precautions
Be sure to read before handling.
For detailed precautions on every series, refer to main text.
14-21-4
Quality Assurance Information
(ISO 9001, ISO 14001)
14-21-5
SMC Product Conforming to Inter
SMC products complying with EN/ISO, CSA/UL standards are supporting
CE Mark
The CE mark indicates that machines and components meet essential requirements of all the EC Directives
applied.
It has been obligatory to apply CE marks indicating conformity with EC Directives when machines and
components are exported to the member Nations of the EU.
Once A manufacturer himself declares a product to be safe by means of CE marking (declaration of
conformity by manufacturer), free distribution inside the member Nations of the EU is permissible.
CE Mark
SMC provides CE marking to products to which EMC and Low Voltage Directives have been applied, in
accordance with CETOP (European hydraulics and pneumatics committee) guide lines.
As of February 1998, the following 18 countries will be obliged to conform to CE mark legislation
Iceland, Ireland, United Kingdom, Italy, Austria, Netherlands, Greece, Liechtenstein, Sweden, Spain, Denmark,
Germany, Norway, Finland, France, Belgium, Portugal, Luxembourg
14-21-6
SMC Product Conforming to International Standards
national Standards
you to comply with EC directives and CSA/UL standards.
14-21-7
SMCs Global Service Network
America Europe
U.S.A. SMC Corporation of America U.K. SMC Pneumatics (U.K.) Ltd.
3011 North Franklin Road Indianapolis, IN 46226, U.S.A. Vincent Avenue, Crownhill, Milton Keynes, MK8 0AN, Backinghamshire, U.K.
TEL: 317-899-4440 FAX: 317-899-3102 TEL: 01908-563888 FAX: 01908-561185
CANADA SMC Pneumatics (Canada) Ltd. GERMANY SMC Pneumatik GmbH
6768 Financial Drive Mississauga, Ontario, L5N 7J6 Canada Boschring 13-15 D-63329 Egelsbach, Germany
TEL: 905-812-0400 FAX: 905-812-8686 TEL: 06103-4020 FAX: 06103-402139
MEXICO SMC Corporation (Mexico), S.A. DE C.V. ITALY SMC Italia S.p.A.
Carr. Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo Via Garibaldi 62 I-20061 Carugate Milano, Italy
C.P. 36100, Silao, Gto., Mexico TEL: 02-9271365 FAX: 02-9271365
TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46
FRANCE SMC Pneumatique S.A.
CHILE SMC Pneumatics (Chile) S.A. 1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600
Av. La Montaa 1,115 km. 16,5 P. Norte Parque Marne La Vallee Cedex 3 France
Industrial Valle Grande, Lampa Santiago, Chile TEL: 01-64-76-10-00 FAX: 01-64-76-10-10
TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB
ARGENTINA SMC Argentina S.A. Ekhagsvgen 29-31, S-141 05 Huddinge, Sweden
Teodoro Garcia 3860 (1427) Buenos Aires, Argentina TEL: 08-603-07-00 FAX: 08-603-07-10
TEL: 011-4555-5762 FAX: 011-4555-5762 SWITZERLAND SMC Pneumatik AG
BOLIVIA SMC Pneumatics Bolivia S.R.L. Dorfstrasse 7, Postfach 117, CH-8484 Weisslingen, Switzerland
Avenida Beni Numero 4665 TEL: 052-396-3131 FAX: 052-396-3191
Santa Cruz de la Sierra-Casilla de Correo 2281, Bolivia AUSTRIA SMC Pneumatik GmbH (Austria)
TEL: 591-3-3428383 FAX: 591-3-3449900 Girakstrasse 8, A-2100 Korneuburg, Austria
VENEZUELA SMC Neumatica Venezuela S.A. TEL: 0-2262-6228-0 FAX: 0-2262-62285
Apartado 40152, Avenida Nueva Granada, Edificio Wanlac, SPAIN SMC Espaa, S.A.
Local 5, Caracas 1040-A, Venezuela Zuazobidea 14 Pol. Ind. Jndiz 01015 Vitoria, Spain
TEL: 2-632-1310 FAX: 2-632-3871 TEL: 945-184-100 FAX: 945-184-510
PERU (Distributor) IMPECO Automatizacion Industrial S.A. IRELAND SMC Pneumatics (Ireland) Ltd.
AV. Canevaro 752, Lince, Lima, Peru 2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin, Ireland
TEL: 1-471-6002 FAX: 1-471-0935 TEL: 01-403-9000 FAX: 01-466-0385
URUGUAY (Distributor) BAKO S.A. NETHERLANDS (Associated company) SMC Pneumatics BV
Galicia 1650 esq. Gaboto C.P. 11200, Montevideo, Uruguay De Ruyterkade 120, NL-1011 AB Amsterdam, Netherlands
TEL: 2-401-6603 FAX: 2-409-4306 TEL: 020-5318888 FAX: 020-5318880
BRAZIL SMC Pneumaticos Do Brasil Ltda. GREECE (Distributor) S.Parianopoulos S.A.
Rua. Dra. Maria Fidelis, nr. 130, Jardim Piraporinha-Diadema-S.P. 7, Konstantinoupoleos Street 11855 Athens, Greece
CEP: 09950-350, Brasil TEL: 01-3426076 FAX: 01-3455578
TEL: 11-4051-1177 FAX: 11-4071-6636
DENMARK SMC Pneumatik A/S
COLOMBIA (Distributor) Airmatic Ltda. Knudsminde 4 B DK-8300
Calle 18 69-05 Apart. Aereo 081045 Santa Fe de Bogot, Colombia Odder, Denmark
TEL: 1-424-9240 FAX: 1-424-9260 TEL: 70252900 FAX: 70252901
14-21-20
SMCs Global Service Network
Europe Oceania/Asia
FINLAND SMC Pneumatics Finland OY AUSTRALIA SMC Pneumatics (Australia) Pty.Ltd.
PL72, Tiistinniityntie 4, SF-02231 ESP00, Finland 14-18 Hudson Avenue Castle Hill NSW 2154, Australia
TEL: 09-8595-80 FAX: 09-8595-8595 TEL: 02-9354-8222 FAX: 02-9894-5719
NORWAY SMC Pneumatics Norway A/S NEW ZEALAND SMC Pneumatics (New Zealand) Ltd.
Vollsveien 13C, Granfoss Nringspark N-1366 LYSAKER, Norway 8C Sylvia Park Road Mt.Wellington Auckland, New Zealand
TEL: 67-12-90-20 FAX: 67-12-90-21 TEL: 09-573-7007 FAX: 09-573-7002
BELGIUM (Distributor) SMC Pneumatics N.V./S.A. TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd.
Nijverheidsstraat 20 B-2160 Wommelgem Belguim 17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN
TEL: 03-355-1464 FAX: 03-355-1466 TEL: 03-322-3443 FAX: 03-322-3387
POLAND SMC Industrial Automation Polska Sp.z.o.o. HONG KONG SMC Pneumatics (Hong Kong) Ltd.
ul. Konstruktorska 11A, PL-02-673 Warszawa, Poland 29/F, Clifford Centre, 778-784 Cheung, Sha Wan Road, Lai Chi Kok, Kowloon,
TEL: 022-548-5085 FAX: 022-548-5087 Hong Kong
TEL: 2744-0121 FAX: 2785-1314
TURKEY (Distributor) Entek Pnmatik San.ve Tic. Ltd. Sti
Perpa Tic. Merkezi Kat:11 No.1625 80270 Okmeydani Istanbul, Trkiye SINGAPORE SMC Pneumatics (S.E.A.) Pte. Ltd.
TEL: 0212-221-1512 FAX: 0212-221-1519 89 Tuas Avenue 1, Jurong Singapore 639520
TEL: 6861-0888 FAX: 6861-1889
RUSSIA SMC Pneumatik LLC.
36/40 Sredny prospect V.O. St. Petersburg 199004, Russia PHILIPPINES SHOKETSU SMC Corporation
TEL: 812-118-5445 FAX: 812-118-5449 Unit 201 Common Goal Tower, Madrigal Business Park,
Ayala Alabang Muntinlupa, Philippines
CZECH SMC Industrial Automation CZ s.r.o.
Hudcova 78a, CZ-61200 Brno, Czech Republic TEL: 02-8090565 FAX: 02-8090586
TEL: 05-4121-8034 FAX: 05-4121-8034 MALAYSIA SMC Pneumatics (S.E.A.) Sdn. Bhd.
HUNGARY SMC Hungary Ipari Automatizlsi kft. Lot 36 Jalan Delima1/1, Subang Hi-Tech Industrial Park, Batu 3 40000 Shah Alam
Budafoki ut 107-113 1117 Budapest Selangor, Malaysia
TEL: 01-371-1343 FAX: 01-371-1344 TEL: 03-56350590 FAX: 03-56350602
ROMANIA SMC Romania S.r.l. SOUTH KOREA SMC Pneumatics Korea Co., Ltd.
Str. Frunzei, Nr. 29, Sector 2, Bucharest, Romania Woolim e-BIZ Center (Room 1008), 170-5, Guro-Dong, Guro-Gu,
TEL: 01-3205111 FAX: 01-3261489 Seoul, 152-050, South Korea
TEL: 02-3219-0700 FAX: 02-3219-0702
SLOVAKIA SMC Priemyseln automatizci, s.r.o
Nova 3, SK-83103 Bratislava CHINA SMC (China) Co., Ltd.
TEL: 02-4445-6725 FAX: 02-4445-6028 7 Wan Yuan St. Beijing Economic & Technological Development Zone 100176, China
TEL: 010-67882111 FAX: 010-67881837
SLOVENIA SMC Industrijska Avtomatilca d.o.o.
Grajski trg 15, SLO- 8360 Zuzemberk, Slovenia THAILAND SMC Thailand Ltd.
TEL: 07388-5240 FAX: 07388-5249 134/6 Moo 5, Tiwanon Road, Bangkadi, Amphur Muang, Patumthani 12000, Thailand
TEL: 02-963-7099 FAX: 02-501-2937
INDIA SMC Pneumatics (India) Pvt. Ltd.
D-107 to 112, Phase-2, Extension, Noida, Dist. Gautaim Budh Nagar,
U.P. 201 305, India
TEL: (0120)-4568730 FAX: 0120-4568933
SOUTH AFRICA (Distributor) Hyflo Southern Africa (Pty.) Ltd.
P.O.Box 240 Paardeneiland 7420 South Africa INDONESIA (Distributor) P.T. Riyadi Putera Makmur
TEL: 021-511-7021 FAX: 021-511-4456 Jalan Hayam Wuruk Komplek Glodok Jaya No. 27-28 Jakarta 11180 Indonesia
TEL: 021-625 5548 FAX: 021-625 5888
EGYPT (Distributor) Saadani Trading & Ind. Services
15 Sebaai Street, Miami 21411 Alexandria, Egypt PAKISTAN (Distributor) Jubilee Corporation
TEL: 3-548-50-34 FAX: 3-548-50-34 First Floor Mercantile Centre, Newton Road Near Boulton Market P.O. Box 6165
Karachi 74000 Pakistan
TEL: 021-243-9070/8449 FAX: 021-241-4589
ISRAEL (Distributor) Baccara Automation Control
Kvutzat Geva 18915 Israel
TEL: 04-653-5960 FAX: 04-653-1445
SAUDI ARABIA (Distributor) Assaggaff Trading Est.
P.O. Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia
TEL: 02-6761574 FAX: 02-6708173
14-21-21