You are on page 1of 2
EA900Pro 10KVA ~ 30KVA (3:3) PFO.9 @ High frequency and tue online double—conversion (© DSP digital control technology © Input power factor correction (PFC) {© Wide input voltage range (180V ~ 485V) © Output power factor 09 ‘© Excellent loadcarrying capability, linear derating between % and 100% load at 190 ~ 277 Va (© Optimizes battery configuration: 192V / 240V . (© Auto sensing frequency © ECO mode operation for energy saving (© 50 / 60H2 frequency conversion mace @ Selectable output voltage via LCD © Selectable battery shutdown voltage (E @ Power-on self test @ Advanced battery management (ABM) © Short circuit and over'oad protection ‘old start ©) via LED Mains Input De input Bypase Input Mains Input Breaker Bypass Input Breaker Fan 0. USE EPO 15 Parallel Card (optional) Compensation (Options) 3 Inteligen Slot 1 (SNMP /AS400 /RS485 Optional) 4. Inteligent Slot 2 (SNMP /AS400 /RS485 Opsienal) (© Automatic charging in OFF mode ‘© Auto control fan speed when loads varies © Dual input © Advanced cu increased double (© Configurable transfer time trom battery to mains powe! reducing the impact on grid or generator ‘© Automatic startup / shutciown function (optional), automatic fer to bypass at light load, automatic restart at acting loads energy-saving and environment-friendly (© Standard S232 / USB communication por © Standard emergency power off (EPO) © Standard maintenance bypass ‘© Optional extension battery bank (© Optional RS485 / SNMP | AS400 communication port (© Optional N+ redundancy parallel up to 6 units ‘© Optional battery temperature compensation 1. charging speed is OCMC US au oa Las) <€KATODO crs er Erne eer Eta Capacity HOKVAS9KW, ISKVAT 13.5 KW 2OKVA 18 KW S0KVA/27 KW INPUT Rated voltage ‘360 V/380V/400V/418 Vac 277 ~ 485 Vac (no derating} Voltage range 190 ~ 277 Vae (linear dorating botwoen 60% and 100% load) Rated trequency 50/60 H2 (aula-sense) Frequency range 40-70Hz Powor factor 30.99 Total harmonic distortion (THO) = 5% ‘Bypass vollage range =10% — + 15% (sett Io) ‘oureuT Votage 360 V/ 880 V /400V/416 Vac (settable) Vorage regulation 21% Frequency ‘Synehvonized with utility in mains mode; 50/60 # 0.1 Hzin batiary mode Wavelorm Sinusoidal Crest factor a1 Total harmonic distortion (THOV) Transter time Inverter overload capabiity Bypass overload capability 215% (linear load): & 3.5% (non-linear load) Maing mode to battery mode: Oms: Inverter mode to bypass mode: Oms 102% ~ 125%: ransfer bypass in 10 mins 125% — 150%: ranster to bypass in min: > 150%: transfer tobypassin 0.58 102% ~ 125%: shut down in 20 mins 125% ~ 180%: ehut down in 2 mins > 150%: shut down in 1s BATTERIES OC voltage inbuilt battery of standard model Standard model: 240 Vac: Long time model: 192 Vde 2x7ah | 40x7An | 40x 9Ah | ~——~Ox DAH “Typical rechargetime Standard model: 4hours: Long time model: depend on the capacity of battery ‘SYSTEM Etlicieney 95%, ECO mado 98% Display LCO+LED. ‘Alarm Battery mode, low battery, fans faul etc ‘Max. paralleinumbore 6 eM TEC /EN62080-2 1EC61000~4-2 (ESO) oy EG6 1000-43 (RS) (COMMUNICATIONS E8100. (EF) IEC61000-4~-5 (surge) /RS292/ R485 / USB /ary contacts ‘SNMP Supports Windows! 98 / 2000 / 2008 /XP / Vista /2008/7/8/ 10 Power management from SNMP manager and web browser OTHERS Humility 20 ~ 95% RH @ 0 40% (non-condensing) Noise level = 60.08 (im) ‘= 65 48(1m) Dimensions (W x D x H) (mm) S60 = 655 = 752th) 350 x 785 x 868 (8) 350 x 705 x 1078.8) 472 x 780 x 920(4) Pactagedcmencion W x Dx Hn OU xD <3 x 810 x 10508) 472 x 810 x 126008) Net weight (a) 55 (1.11568) 60H), 185(5) ‘o1(H).175 (8) 65 (4) 23518) Gross weight a) 165 (H), 12515) 70(H).170(5) 71(H),190(8) 75(H).250(5) ‘9 oeatecapaciyos0% went upu votape adn OW ‘ Al spactisions ject chang wire nae, u 0342-4580500 w& ventas@katodo.com.ar ® wwww.katodo.com.ar

You might also like