You are on page 1of 7

Dixell XR60C

Multifunction controller (Filter)


XR60C
2.
1. ___________________ 1 XR60C 32x74 mm
2. ________________ 1
3. ________________ 1 ventilated refrigerating
4. ___ 2 3
5. ________________ 3
6. ______________________ 5 (hot gas)
7. ________________ 5 NTC
8. ______________ 5
9. ________________ 6 (Evaporator)
10. ___________________ 6
11. 6
1. 3.
1.1 3.1








1.2 :


:

COn
COF
: 3.2
2
tdF: (tdF
= EL) (tdF = in)
(IdF),
(MdF)
2 :
(P2P)
()
, 3.3

FnC :

XR60C 1/7
Dixell XR60C
FnC = C_n: LED
;
FnC = o_n: - (
, ; )
-

Fnd
FnC = C_Y:
;
FnC = o_Y:
4.2
1. n Lo
FSt
2.
n 5

FSt
4.3
4. 1. o

2. Hi


o 5
3.


4.4
SET:
1. SET 3

( rSt )
(DEF): 2. rSt
o (UP): ;

4.5

n (DOWN): ; 1. SET :
;
2. SET 5
:
o +n 4.6
SET + n 1. SET 2
SET +o ;
2. LED
;
4.1 LED
3. o n 10
LED 4. SET
LED 10
4.7
- ( (DEF) 2
)
-
XR60C 2/7
Dixell XR60C
4.8
: LED

1. SET n 4.10
3 (
)
2. 1. o +n 3
3. SET 2. POF
( LED )
4. o n
5. SET 3. 3
POF
: SET +o 4.11
15 o +n 3
:
4.12

4.9
CCt o
3
4.9.1 o 3
5.

Hy Differential: (0.1 25.5C / 1255 F)

1. SET + n
3 (LED 1 ) (Hy)
2. SET + n
7 Pr2 HY LS Minimum set point: (- 50C SET/-58F SET)

3. US Maximum set point: : (SET 150C / SET 302F)
4. SET (
LED )
5. on Ot Thermostat probe calibration: (-12.0 12.0C;
6. SET -120120F)

: SET +o P2P Evaporator probe presence:
15
: n= : ;
y= :
OE Evaporator probe calibration: (-12.0C 12.0.0C;
4.9.2 -120C 120F)

OdS Outputs activation delay at start up: (0255min)
(user level) SET n
XR60C 3/7
Dixell XR60C
; SEt = ; dEF =
dEF)
dAd MAX display delay after defrost: (0255)
AC Anti-short cycle delay: (050)
Fdt Drip time: (0120 )
CCt Compressor ON time during continuous cycle:
(0.024.0; 10 ) dPo First defrost after start-up:
:
(y = ; n = IdF)
dAF Defrost delay after continuous cycle: (023.5)

COn Compressor ON time with faulty probe: (0255
)
COn=0 FnC Fans operating mode:
C-n= ,
COF Compressor OFF time with faulty probe: (0255 ;
) o-n = , ;
COF=0 C-Y = ,
;
CF Temperature measurement unit: o-Y = , ;
C=; F= : Fnd Fans delay after defrost: (0255)

Hy, LS, US, Ot, ALU ALL FSt Fans stop temperature: (-5050C/-58122F)

rES Resolution (for C): (in = 1C; dE = 0.1 C)

Prd Evaporator probe read out:
ALC Temperature alarms configuration: (Ab; rE)
Ab= :
tdF Defrost type: EL = ; in = ALL ALU, rE = :
SET+ALU
dtE Defrost termination temperature: (-5050 C/ - SET-ALL
58122F) ALU MAXIMUM temperature alarm:
( EdF=Pb) (SET150C; SET302F)
ALU
ALd
IdF Interval between defrost cycles: (0120) ALL Minimum temperature alarm:
(-50.0 SETC; -58302F)
MdF (Maximum) length for defrost: (0255) P2P = ALL
n, (: ALd
) , ALd Temperature alarm delay: (0255 )
P2P = y ()
dAO Exclusion of temperature alarm at startup: ( 0.0
dFd Temperature displayed during defrost: 23.5)
(rt = ; it =
XR60C 4/7
Dixell XR60C
7.
i1P Digital input polarity: oP:
; CL: 2.5 mm2
,
i1F Digital input configuration:
EAL = : EA ;
bAL = Nps;
dEF = ; 7.1
AUS =
did Digital input alarm delay: (0255 )
(i1F=
EAL i1F = bAL)
Nps kind of action when i1F=bAL. (015) i1F=bAL, (
Nps )
Nps=0: door-switch:

Nps=1: lock alarm:
(Off) ( 8.
did)
Nps=215: pressure-switch function: EE
(Off) P1
Nps Con COF
did
P2

6.
XR60C 29x71 HA
mm
LA

EA

CA (OFF)
IP65
(mod. RG-C)
8.1 EE

EE

060 C 8.2
P1 P2

XR60C 5/7
Dixell XR60C
10.

HA LA 10.1 XR60C: 12VAC/DC; COMPRESS. 8A



8(3)A 8(3)A

EA Max 8(3)A/250Vac
10A

CA Nps 1 2 3 4 5 6 7 8 9 10 11 12

Nps=1 CA Defr Fan Comp

Line
Supply
12V ~ /

Nps>1 CA

9. 10.2 XR60C: 230VAC; COMPRESS. 8A
: 32x74 mm; 60mm; 8(3)A 8(3)A

: 71x29 mm Max 8(3)A/250Vac


10A
: IP20 1 2 3 4 5 6 7 8 9 10 11 12

: IP65 mod Supply


Defr Fan Comp 230V ~
RG-C () Line
50-60Hz

: 2.5 mm2
: 12Vac/dc, 10%
( 230, 110, 10%, 50/60Hz) 11.
: 3VA max
: 3 , LED , 14.2 mm C/F
: NTC 2 Set LSUS -5/0
Hy 0,125.5C/ 2/4
: 1 255F
SPST relay 8(3) A, 250Vac LS -50CSET/ -50/-58
SPST relay 20(8)A; 250Vac -58FSET
: SPDT relay 8(3) A, 250Vac US SET150C/ SET 150/302
: EEPROM 302F
Kind of action: 1B Ot 0
-12 12C /
Pollution grade: normal -120 120F
Software class: A
: 060 C
: -3085 C
: 2085% () P2P n=; y= y
: -40110C (-58230F)
: 0.1 C 1C 1 F ()
( 25C): 0.7 C 1 OE -12 12C / 0
-120 120F



OdS 0255 0


XR60C 6/7
Dixell XR60C
AC 0 50 1 dAF 0 23.50 0.0


Fnc C-n, o-n, C-y, o-Y o-Y
CCt 0.024.0 0.0
Fnd 0255 10

COn 0 255 15
FSt -5050C/ 2/35
-58122F
ALc rE= Ab
COF 0 255 30 ;
Ab =

ALU Set150.0C 150/302
Set302F
CF C F C/F ALL -50.0CSet/ -50/-58
-58F Set
rES in= dE/- ALd 0 255 15
dE=
dAO 0 23.50 1.30
Prd -- --

i1P oP=; CL
tdF EL= EL CL=
in= i1F EAL= bAL
dtE -50 50 C 8/46
bAL=

IdF 1 120 6 dEF=
AUS=
MdF 0 255 30 did 0255 5

Nps 015 0
dFd rt, it, SEt, DEF it i1F=bAL



dAd 0 255 30


Dixell (Asia) Co.,Ltd.
Fdt 0120 0 207/71-72 6 . 61 . . 10250
Tel. 0-2321-3078-3078, 0-2722-0245 Fax. 0-2320-2520, 0-2722-0250
dPo n= IdF; n http://www.dixellasia.com E-mail: dixell@dixellasia.com
y =

XR60C 7/7