at a splice, the slopeof the inclined portion of the bar
with the axis of the column shall not exceed 1 in 6. and the portionsof the bar aboveand belowthe offset shall be parallel to the axis of the column. Adequate horizontal support at the offsetbends shallbe treated as a matterof design. and shall be provided by metal ties, spirals. or parts of the floorconstruction. Metal ties or spirals so designed shall be placed near (not morethaneight-bar diameters from) the pointof bend. The horizontal thrust to be resisted shall be assumed as one and half times the horizontal components of the nominal stress in the inclined portion of the bar. Offsetbarsshall be bentbeforetheyare placedin the forms, Where column faces areoffset75mmormore, splices of vertical barsadjacent to theoffsetfaceshall be madeby separate dowels overlapped