Technical Specification of 245KV SF6 Circuit Breakers SI.No_| Description 1 [Rated Voltage 245KV. 2 | Rated Frequenc S0HZ 3_| Applicable Technical Standard IEC 6271-100, a 4__| Number of poles 3 5 [Class (Outdoor/indoor) Outdoor 6 | Rated Normal Currents: z a) Under site conditions (Amps) 3150 Amps. ao b) Rated (Amps) 3150 Amps 7 | Rated short circuit breaking current: a) R.M.S. values of A.C component of 50 KA rated short circuit current (kA) b) Percentage DC component [50% c) Asymmetrical breaking current |: | 49 KA a {including DC component) | 8 | Rated short circuit making current (kA) [125 KAp "9 | First pole to clear factor [1.3 10 |Rated transient recovery voltage for 364 k Vpeak | terminal faults (kV peak) 11 __| Rated operating sequence. 0-0.3s-CO-3min-CO__ 12__| Rated duration of short circuit (sec.) 3 sec 13 __| Rated out of phase breaking current (kA) 12.5 KA 14 | Opening time (ms) Z 28 ms (max) 15 | Arcing time (ms) : [_a) At 10% rated breaking current J: [47-8 ms (max) |__b) At 25% rated breaking current as per test duty T100s c)_At 50% rated breaking current | “d) At 100% rated breaking current ib e) Maximum arcing time at lowest fault |: | 21.7 ms currents as per test duty L90 16 _| Break time (ms): rs a)_At 10% rated breaking current | 60 ms b)_At 25% rated breaking current At 50% rated breaking current )_ At 100% rated breaking current |e) Maxi Maximum break time at lowest fault | er currents _ - 17 _| Closing time (ms) Ls [72ms 18 | Maximum pole discrepancy time: ee ‘a) Opening (ms) [sams (2 b) Closing (ms) 5 19 _| Rated line charging breaking current 125 Amps. 20 | Maximum cable charging current: a) On supply side 250 Amps b) On line side [ Restrike free. Class C2 24 Rated small inductive breaking current (KA) 0-10 22 [Maximum raise of temperature over|: | Within IEC limits ambient temperature for current rating under clause-6, 23 _| Interrupting capacity based on duty cycle as per clause “7 or 11. a) AC Component (kA) 50 |b) Percentage D.C. component 50% ie: 24 _| Latching current (kA) (Rls a eas 25 _| Number of breaks in series per pole ‘One 26 | Length of contact travel (mm) 1180 (approx.) 27_| Total length of break per pole (mm) 125 (approx.) 28 | Rate of contact level: a) At tripping (meters/Sec.) 7.0-8.0 b) At closing (meter/Sec.) Dieter 29 _| Type of main contact ‘Multi-finger crown 30 _| Type of arcing-contacts and /or arc control |: | Tulip/PTFE nozzle device il 31 | Material of contacts: ez a) Main Cu b) Arcing Cu Tungsten [Auxiliary cu 32_ | Whether contacts are silver plated Yes 33__| Thickness of silver coated (mm) 12 microns 34_| Contact pressure 60-350N per finger 35 _| Insulation level of breaker: a a) 1 minute power frequency withstand]: | 460 voltage (kV rms) b) Impulse withstand test voltage (kV): | 1050 peak) 36 | Minimum clearance in air (mm) ‘a) Between phases (live parts) 4140 mm |b) Between live parts and earth | 1870 mm c) Centre to centre distance between |: | 4500 mm phases 37 | Whether the circuit breaker is suitable for|: | Trip free fixed trip operation or trip free operation and whether it is provided with a lock out device preventing closing of the breaker 38 | Method of closit a) Normal Electrical b) Emergency _ |: [Electric 39__| Type of closing mechanism ‘Motor charged spring 40 a) Normal voltage of closing 220 Volts b) Pick up range (volts) 85% -110% A a) Normal voltage of closin: 220 Volts b) Pick up range (Volts) 85 -110% i) Power at normal voltage of closing mechanism (watts) +345 for closing coils ji) Power at 85% of normal voltage (watts) 249 42__| Type of tripping mechanism Built in spring [__43__| Normal voltage of tripping coils 220 Volts “4 a) Power at normal voltage for tripping |: | 345 coils (watts) b) Power at 70% normal voltage for 169 tripping coils (watts) she 45 _| Arc duration at 100% (rms) interruption capacit) ‘a) Opening arcing time no.of loops and|: | 1.08 as per test duty L90 time including resistor current (No opening resistor) duration (Cycle) Bs Resistor current duration (cycle) Not applicable Total interrupting time measured from S instant of trip coil energisation to arc ___ | extinction of resister current (cycles) beside b) Closing time measured from instant |: | 72 ms of application of power to closing device upto arcing contacts touching (cycles) 4% a) Recovery voltage when circuit|: | 364 breaker tested at 100% rated breaking capacity (KV inst.) b) Rate of rise of re-striking voltage at breaking: i) for 30% breaking capacity): [5 (kV /Micro.sec.) | fi) for 100% breaking capacity|: |2 _(kV/Micro.sec.) 3 ©) Maximum over voltage factor of the circuit breaker when switching off. i) Unloaded transformers. <2.3 pu ii) Loaded transformer <2.3 pu iii) Open circuited lines [<2.3 pu 47 | When switching of synchronous systems: a) Max.current (kA) 10 b) Max.Contacts lines 283 4B [No. of openings the circuit breaker is capable of performing without inspection, replacement of contacts or other main parts: a) At 50% rated current 2500 [bp At 100% rated current | 2500 [e) At current correspondence to 50%|: | 60 rated breaking capacity d) At current correspondence to 100% 16 | rated breaking capacity 49 a) Weight of complete circuit breaker |: | 3000 kg (appr (kg) \ b) Impact loading for foundation design]: 1500 daN upwards and to include deed load plus impact | | 2200 daN down wards values on opening at maximum interrupting ratings, in terms of equivalent static load (kg) 50 | Porcelain: a) Make is + | ABIL/WSI/MIL/BHEL/IEC/G: AOKE/TANGSHAN/ Saravana /Reputed = b) Type. 7_| Hollow Porcelain ©) Height above floor, required to|: | 400 mm_ in addition to CB| remove porcelain (mm) height d)_ Insulation class Belle e) Nature of dielectric :__| Hollow Porcelain f) Creepage distance, total protected |: | 6125 to earth shed profile [cotec Shoat as per IEC 60815 | g) Permissible safe cantilever loading): | 1800 daN-m for support on installed porcelain (kg-m) insulator | 51 | Operated mechanism: el a) Mechanically operated or]: | Spring operated pneumatically or —_ hydraulically operated B) For stored energy mechanism: /4)Spring charging motor: i)Rating kw aes eS 0.38 ii)Voltage V z Z30Volts iii) power frequency withstand voltage 2 KV iv)Time required for the motor to be|: | < 10 secs. =| charge the spring fully (sec.) si v)power required at the normal control |: | 380 | __voltage to charge the spring (Watts) | vi)specification reference 2 _| Internal 2)Spring closing/opening: i) Number of springs + _[As per standard ii)Type 1 | Helical ili) Number of turns : (As per Standards iv)Guage specifications v)External diameter in mm vi)Stifness vii)Material viiiJForce developed in full charged sition ix)Specifications 52 [Rated pressure of SF6 gas in the circuit]: | 0.75 Mpa(abs) at 20 deg C | breaker (kg/sq.m) 53 | Rated pressure of SF6 gas in the gas 20 kg at 30 bar,filling cylinders _(kg/sq-m) ratio-1.25 54 | Quantity of SF6 gas required per single pole |: | 16.5 kg per CB |__| unit (kg) see 55 | Quantity of SF6 gas per cylinder (kg.) [20 Kgs 56 | Weight of empty cylinder (kg.) 25 Kgs (approx) 57 [Quantity of absorbent required per pole 500 gms. (kg.) [58 | Recommended interval for renewal of | 7500 operations at rated absorbent in case of outdoor circuit | | current breakers operating in tropical conditions 59 | Chemical composition of absorbent :_| Activated alumina 0 Quantity of absorbent covered in the scope |: | 1500 g (No spare quantity) of supply (including spare quantity) (kg) Gi {Limits of gas pressure for pressure|: | 0.61 to 0.75 Mps (abs) at "| operation of circuit breaker (kg/sq.cm) _ |__| 20 deg C 62 | Pressure and temperatures at which the temperature compensated gas | pressure switch: i a) Alaram (kg/sq.cm,deg C) + | 0.64 Mpa (abs) at 20 deg C__ [_b) Cut off (kg/sq.cm,deg C) (0.61 Mpa (abs) at 20 deg C_| 3 | Name of SF6 supplier and country of origin, ‘SOLVAY/LINMNG/CNHSGL/ fe Reputed | 64 | Quantity of SF6 gas supplied for: a) Actual use in breakers (kg) 16.5 kg per Cb [by As spare (kg) 20% Extra 65 Chemical composition of gas: c (a) Quantity of air by weight (ppm) [+] As per IEC 376 [b) Quantity of H20 by weight (ppm) 1c) Quantity of CF4 by weight (ppm) d) Quantity of free acid by weight (ppm) 6 | Number of auxiliary contacts provided: : ___a) Those close when breaker is closed 10 b) Those open when breaker is closed 10 z ‘c) Continuous rating of contacts 10 Amps. d) Breaking capacity of contacts 2A at 220 V OC

You might also like