aes ads PRODUCTION LOGGING-ELECTRIC LINE
Dec., 1977
GLOSSARY OF COMMON TERMS
GENERAL CHARACTERISTICS
- Operating pressure range
- Operating temperature range
et
+ length
. diameter
+ weight
~ Proof pressure :
Percentage of rated pressure which will not cause changes in performance
beyond the specified tolerances.
- Burst pressure :
Percentage of rated pressure which will not cause rupture of the sensing
element or case. Changes in nominal performance (calibration etc ...)
may occur.
ELECTRICAL CHARACTERISTICS
~ Power requirements :
This characterizes the type of power supply required for the gauge -
current or voltage supply, power etc...
~ Output data :
Frequency proportional to the pressure applied.
- Full scale (FS) :
Maximum value of the output data for the full input.
- Full range output (FRO) :
Difference between full scale (FS) and output data for zero input.
~ Supply rejection
Output variations following a DC supply change - expressed as percentage
of FRO per unit of supply variation.
- Stabilization time :
Time interval required to reach accuracy range and the gauge has been
switched ON.Dec., 1977
vecsoucresxs PRODUCTION LOGGING.ELECTRIC LINE
- Thermal zero stability (TZSt) :
Maximum deviation between any two room temperature zero output values
obtained during a temperature calibration :
expressed as a percentage of FRO or in ppm.
- Thermal sensitivity stability (TSSt) :
Maximum deviation between any two room temperature full range output
values obtained during a temperature calibration expressed as a
percentage of FRO or in ppm
ENVIRONMENTAL CHARACTERISTICS
- Vibrations :
Output variation following a given vibration environment - generally
expressed as percentage of PRO per g.
= Shocks :
Output variations following a given shock environment - generally
expressed as percentage of FRO per g.