INPUTS Unit OUTPUTS Unit

f'c = 21 Mpa t= 100.00 mm


fy = 415 Mpa Beta = 0.850
LL = 2.7 Mpa W= 10.890 Kn/m
DL = 2.1 Mpa M (ult) = 5.445 Kn m
L= 2 m V (max) = 10.890 Kn
Phi = 0.9 d (eff) = 75.000 mm
b= 1000 mm Rn = 1.076
Rho (act) = 0.0026748739
Rho (max) = 0.0162089738
Rho (min1)= 0.0027605878
Rho (min2)= 0.003373494
Analysis:
Use Rho min2