Safety guideline
The manual includes precautions that should be followed to ensure personnel safety and prevent products and
connected devices from being damaged.
For these precautions, symbols are used for alarm purpose and the following descriptions will be given
depending on severity:
Danger
It indicates that without proper preventive measures, death, serious physical injury or major property loss will occur.
Warning
It indicates that without proper preventive measures, death, serious physical injury or major property loss will
possibly occur.
Caution
It indicates that without proper preventive measures, slight physical injury will possibly occur.
Caution
It indicates that without proper preventive measures, property loss will possibly occur.
Attention:
Arouse your attention to important information on products and to specific parts of products or files.
Qualified personnel
Only qualified personnel are allowed to install and operate the device. Qualified personnel refer to those who, with
experience in field mud logging, can install, test run and operate devices according to established safety
practices and standards.
Correct operation
Precautions:
Warning
The device and its components can only be used for description of product catalog or technical specification and can
only be connected to facilities or components recognized or recommended by Shenkai Company.
The device can function correctly and safely only when transported, stored, assembled, installed correctly and run
and maintained as recommended.
Trade mark
Any use of other names related to the trade marks herein by any third party for its own purpose will infringe interest
of the trade mark owner.
Copyright 2008 Shenkai Company, All rights reserved.
Without the express written permission, it is forbidden to copy, transmit or use this manual or part of it.
Any violation of the above will be disciplined. All rights, including patent rights, utility model or appearance design
patent rights, are reserved.
Shanghai Shenkai Petroleum Science and Technology Co., Ltd. hereby declares that contents of this manual are verified
and compliant with the said hardware and software. Mistakes, however, are unavoidable, so complete consistence cant
be guaranteed. Contents of this manual are subject to periodic review and will be modified in the next version. Your
opinions on improvement are welcome.
Copyright 2008 Shenkai Company. The information in this manual is subject to change without notice.
Manual scope
The manual is applicable to the following systems:
Device model Software version Operating system
The manual describes the templates valid when it is published. For new models or the latest
models, we reserve the rights to add product information list, including the current
information of the related templates.
Information package
In addition to the user manual, an information package is also provided, including:
Instruction manual and drivers disk of industrial computer.
Software for SK-CMS mud logging unit and drivers disk for hardware.
Certificate of conformity and explosion-proof certificate for the device and debugging
record of part of matching components.
Instruction manuals for some outsourced sensors (such as hydrogen sulfide sensor).
The specific information package depends on the specific configuration requirements.
Guideline
The manual adopts the following organization method to help you find the target information
quickly and conveniently:
General table of contents at the beginning of the manual.
Training
Shenkai Company also provides a number of training courses introducing SK-CMS series
mud logging units. For details, please contact Shenkai branch company in your location or
Technical Support Department in Shanghai headquarters.
Other support
For any technical issues, please contact Technical Support Department in Shanghai
headquarters or local after-sales service center.
Dongying
Baoji Xian
Dazhou Shanghai
Chengdu
Note: Urumchi (Northwest Branch Company), Chengdu (Southwest Branch Company), Korla (Korla Branch Company),
Luntai (office), Dazhou (office), Jidong (office) and Wushen County (office) are resident offices of Shenkai in China
in addition to Shanghai Headquarters. Besides, Shenkai also establishes offices in Panjin, Dongying, Xian, Baoji and
Daqing, launching sales service and technical support on an irregular basis.
Hardware Manual of CMS Mud Logging Unit
Contents
Safety indicator of instrument room: the insulation resistance between the phase wire and earth lead of
machine room is more than 2 Mhe instrument shall be equipped with a good earthing device.
II.2 Total hydrocarbon detector and component detector of natural gas
Main technical indicators of 3Q04 hydrogen flame chromatograph
Measuring contents: C1, C2, C3, iC4, nC4, iC5, nC5;
Analysis cycle: 30s or 90s;
Component measuring range of natural gas:
-6
5x10 -1mol/mol (the analysis cycle of CH4 is 30s.);
30x10 -6 -1mol/mol (the analysis cycle of CH4 is 90s);
-6
The minimum detection concentration: 5x10 -1mol/mol (CH4);
-6
The total hydrocarbon measuring range of natural gas: 20x10 -1mol/mol;
Repeatability error: 2.5;
Baseline drift: 2%hF.S;
Noise: 1%F.S;
Concentration ratio of methane and ethane is 100:1 (10% methane and 0.1% ethane):
evidently distinguishable;
CO2 infrared detector
Measuring range: 0.2-100%;
Measuring accuracy: 2.5% (F.S);
II.3 Sensor
Pump stroke sensor (RPM)
Measuring range: 30, 60, 120, 240, 480, 960, 1920 times/min optional Accuracy: 1% (F.S)
Table speed sensor
Measuring range: 30, 60, 120, 240, 480, 960, 1920 times/min optional Accuracy: 1% (F.S)
Rotary table torque sensor (TORQUE)
Measuring range: 0-1.6MPa(0-50KN.m) Accuracy: 2% (F.S)
Stand pipe and casing pressure sensor (SPP)
Measuring range: 0-40MPa, 0-60MPa Accuracy: 2% (F.S)
Hook weight parameter sensor (HOOKLOAD)
Measuring range: 0-6MPa (0-4000KN) Accuracy: 2% (F.S)
Drilling fluid temperature sensor (MTI)
Measuring range: 0-100 Accuracy: 1 F.S
Drilling fluid density sensor (MWO)
Measuring range: 0-2.5g/cm 3 Accuracy: 1% (F.S)
Drilling fluid conductivity sensor (PIT)
Measuring range: 0-50ms/cm,0 -300ms/cm Accuracy: 2% (F.S)
Drilling fluid outlet flow sensor ((MFO)
Measuring range: 0-100% (relative flow) Accuracy: 5% (F.S)
Volume sensor of drilling fluid tank (PIT)
Measuring range: 0-2m (or specified according to users requirements) Accuracy: 1.5% (F.S)
Drawworks sensor
Measuring range: 0-9999 (hook position) Accuracy: 10mm/single
II.4 Geological instrument
Carbonate analyzer
Measuring range: 0-100 carbonate
Accuracy: 1
2
Hardware Manual of CMS Mud Logging Unit
3
Hardware Manual of CMS Mud Logging Unit
Internal arrangement of CMS mud logging unit: the internal arrangement of CMS mud logging unit
mainly includes four parts: external power and cable inlet room, major machine cabinet room,
computer and printer working section and geologic working section.
4
Hardware Manual of CMS Mud Logging Unit
Long chart printer is connected to the parallel port of collector through data cables.
Carbonate analyzer, as a 4-20mA signal analog sensor, is connected to CAN bus.
The sample gas collected by engine degasser is transported to SK-9G01sample pretreater
through non-adsorption pipeline, then sent to hydrogen flame chromatograph analyzer and
non-hydrocarbon analyzer respectively (for details, see chromatography section).
III.3 Measurement parameters
SK-CMS mud logging unit can mainly acquire or calculate the drilling parameters as follows.
Engineering parameters: well depth, bit position, lag well depth, drilling time, hook height,
weight, bit weight, number of pump strokes, rotary table torque, standpipe pressure, casing
pressure and table speed, etc. .
Gas-measuring parameters: hydrocarbon components: C1, C2, C3, iC4, nC4, iC5, nC5;
Non-hydrocarbon: CO2;
Drilling fluid parameters: inlet and outlet temperature, inlet and outlet conductivity, inlet and
outlet density, volume of branch tank and head tank, outlet flow;
Security detection parameters: flammable gas and hydrogen sulfide;
Geologic analysis parameters: mudstone density, content of carbonate, flow analysis;
Positive pressure explosion-proof detection parameters: indoor smoke, gas pressure,
flammable gas and hydrogen sulfide;
5
Hardware Manual of CMS Mud Logging Unit
CAN
adapter MAIN-DAQ
Explosion-proof CAN sensor card
Net-
Multi-serial port work
Carbonate analyzer card Card
CAN
adapter SUB-DAQ Net-
card work
Card
HUB
Multi-serial port
card
Outlet Chromatography Real time engineering
long chart printing
Inlet Chromatography
Geochemical instrument
6
Hardware Manual of CMS Mud Logging Unit
7
Hardware Manual of CMS Mud Logging Unit
8
Hardware Manual of CMS Mud Logging Unit
9
Hardware Manual of CMS Mud Logging Unit
10
Hardware Manual of CMS Mud Logging Unit
Figure 2-4 100m power cable in the back cabin of the mud logging unit
Warning
Identification of primary power cable No. in the instrument room: 1,2 and 3: live line; 4: null
line.
To use the equipment in countries or regions outside China, please first make clear voltage of
the three-phase power source outputted by wellsite generators. The flameproof transformer
equipped can connect 4 three-phase power sources of 220V/380V/440V/480V at one time. The
second output power source is of three phase 380V. Adjustment is needed inside the
instrument while selecting the first input power source. For details, please refer to Selection
of three-phase input power source. The wellsite three-phase power source can be connected
only after the input power source is set correctly. The secondary load will run abnormally or
even burn down if the input power source is not selected correctly.
11
Hardware Manual of CMS Mud Logging Unit
Arrester
380V power
output
12
Hardware Manual of CMS Mud Logging Unit
Airway
port
Airway
pipe
Figure 2-8 Sketch map of positive pressure explosion-proof signal indicators inside the instrument
room
Break off or damage of sealing strip of the cabinet door, needing immediate replacement.
13
Hardware Manual of CMS Mud Logging Unit
Wrong running direction of blowers three-phase AC motor, needing change in power phase. There
are two ways to change the power phase:
Change positions of any two live lines in the input terminal of the primary power.
Change positions of any two live lines in the blower (Figure 2-10).
First switch off the primary power
of the mud logging unit and open
top cover of the power supply
junction box of the blower
Figure 2-10 Sketch map of changing phases of the three-phase power supply to SK-CMS
blower
Warning
Use of positive pressure bypass control is prohibited unless it is sure that the instrument room is
in a safe environment.
Use of UPS is prohibited when the instrument room is in a dangerous place, otherwise, danger is
likely to occur.
15
Hardware Manual of CMS Mud Logging Unit
If room pressure is not up to the set 60-200Pa, first check that whether door and emergency rescue
door are closed completely and whether cable guiding section is sealed; then check whether air line is
smooth and whether the opening of the fire damper is too large. For calibration of the flammable gas
detector, refer to the related instruction manual.
Trip the startup button QA of degasser; due to the self-locking of C 2B, the contactor C2 is still in live
status, the normally open contact C 2D is closed, the green running indicator is on but however, the
normally closed contact C2C is disconnected, the red stop indicator is on. The degasser is always in the
live operating mode. When it is required to stop the degasser, it is necessary only to press the stop
button, cut off the working power supply of the contactor and stop the degasser. The normally closed
contact (C2C) of the contactor is restored from disconnection to connection and the red indicator is on.
Protection control when N neutral wire of main circuit is live
When N neutral line is connected by mistake to phase line or electric leakage occurs, the potential
difference is built between N neutral line and ground wire and in consequence, JY relay operates to
disconnect the normally closed contact JY-21A and disconnect the control circuit of the main loop, so
the main loop is protected as it is unable to activate the main contact C1.
Over-current and open-phase protection control and alarm of degasser
Due to poor insulation or open circuit and open phase, a large current is formed in degasser motor,
making the motor hot and in consequence, the thermal relay acts due to overheat, the normally closed
contact RJ1 of the thermal relay is disconnected to cut off the control circuit of the degasser, so the
degasser is powered off and is protected due to it is unable to activate the degasser.
When the thermal relay acts, its normally open contact RJ 2 is closed to make the buzzer or flash
light give acoustic and optical alarm due to power-on.
Setting positive pressure bypass and automatic master switch with lock of degasser
When the master switch is set in the positive pressure bypass position, the startup and stop buttons
of the degasser take effect. If the master switch is set in the automatic position, the startup and stop
buttons are disabled and then you can control the power-on and power-off of contactor through the
switch of mud electrode or open/close of input signal of computer and accordingly to start up or stop the
degasser, carrying out the automatic control of the operating status of degasser.
Figure 2-5 Panel drawing of distribution box of CMS mud logging unit
17
Hardware Manual of CMS Mud Logging Unit
Figure 2-6 Power supply control program chart of distribution box of CMS mud logging unit
18
Hardware Manual of CMS Mud Logging Unit
19
Hardware Manual of CMS Mud Logging Unit
VI UPS manual
VI.1 Introduction
Welcome to use wide-frequency wide-voltage input-type UPS. For first-time users, please read
carefully the manual and keep it properly as it is very useful for your future enquiries.
Product characteristics
Real wide-frequency (50HZ30%) and wide-voltage (220V30%) input, designed for
connecting generators of all types.
Independent online design.
IGBT power device and advanced thick film circuit design.
DB9 computer communication interface.
Able to connect various nonlinear loads and resistive loads. `
VI.2 Installation
Installation position:
Insulation position depends on the actual application. The following should be noticed:
Distance between all sides of UPS and surrounding objects should be greater than 10cm.
Keep unobstructed ventilation windows on two sides of UPS.
Keep away from fire source and high temperature. Temperature in the operating
environment is 0 ~35 and RH 10~90%.
Keep away corrosive environment.
No overheat, dust or splash of rainfall in the installation position.
Installation
Warning
Only those with electrical knowledge can operate.
Installation should be conducted under the guidance and supervision of the qualified
engineer.
Before installation, please make sure that switches on the front and rear panels are OFF.
Insert plug of UPS input power source to the suitable socket of the generator or utility
power.
Connect the corresponding load to the output socket of the rear panel.
Caution
The user should calculate in advance the standard total power of the load powered by UPS to
ensure that it is within the largest load power allowable by UPS.
VI.3 Startup and running
Start and run UPS in the following steps:
Ensure that switches on the front and rear panels are OFF. Insert plug of UPS input power
source to the suitable socket of utility power.
Ensure that generator is on and running normally or utility power is already input.
Attention:
UPS battery will be discharged without input of external power supply.
20
Hardware Manual of CMS Mud Logging Unit
Caution
Ensure that all loads are off before starting UPS. Starting UPS with loads will impact loads and
UPS, affecting service life of the product.
Test UPS output using a multimeter (should be 220V). This step is needed only in the
course of testing.
Test battery using DC shift of the multimeter. The charging voltage should be 96V1V.
This step is needed only in the course of testing.
Start and run the load normally. UPS is now put into operation.
Power off utility power for 1min and UPS should power without interruption. This step is
needed only in the course of testing.
Close UPS in the following steps:
Shut down all UPS loads.
Press STOP in the front panel continuously twice.
Turn air switch on the rear panel to OFF.
Cut off the external power.
Attention:
Turn switch on the real panel of the battery pack to OFF if UPS will not be used for a long
period.
VI.4 Maintenance
UPS, in the course of running, should be maintained regularly to ensure its reliable operation and
extend its service life. Pay attention to the following:
Keep UPS clean, free of dust and foreign matter. When UPS is off, clean it using a soft dry
cloth.
In the region without power outage for a long period, disconnect input of utility power to
UPS regularly (usually 3 months) and discharge the battery for 30% to check performance
of the battery pack.
The basic procedure to charge UPS when the battery is discharged completely:
When UPS is not used for a long period or the battery is discharged completely, UPS
should be charged as per the following procedure:
Ensure that switches on the front and rear panels are OFF.
Connect utility power (frequency 50HZ5% and voltage 220V15%).
Turn air switch on the real panel to ON, with the switch on the front panel either ON or
OFF. Charge continuously for 16 hours until battery capacity reaches 90% of the
nominal capacity.
Turn switches on the front and rear panels to OFF. Now UPS charging is completed.
Attention:
While testing discharge capacity of battery, first store load programs and data and close all
running programs to avoid data loss due to ill-performed battery.
21
Hardware Manual of CMS Mud Logging Unit
3.5.1 All indicators are off. Utility power and battery are not Connect utility power and battery.
connected. Connect utility power and charge UPS
Utility power is not connected and (Note 1).
battery is discharged completely. Replace backup fuse or fuse of the same
AC and DC fuses are broken. spec.
3.5.2 All indicators are off or off after Battery is discharged completely. Connect utility power and charge UPS
lightup for a few seconds while turning (Note 1).
it on and therefore are unable to activate
UPS.
3.5.3 Utility power indicator (green) is Utility power is not connected. Connect utility power.
off. Utility power fuse is broken. Screw up or replace fuse of the same spec.
3.5.4 Battery indicator is off. Battery fuse is broken. Replace backup fuse or fuse of the same
spec.
3.5.5 Overload indicator lights up. Output overload Reduce load to the allowed range.
3.5.6 Fault indicator lights up. Load short circuit Shut off inversion switch, eliminate short
circuited load and restart.
3.5.7 Battery indicator becomes red. Battery low Charge battery. Connect utility power and
charge UPS for over 10 hours (Note 1).
3.5.8 Battery indicator is still red after Charging fuse is broken. Replace backup fuse or fuse of the same
charging. spec.
3.5.9 No UPS output. Output line is not connected. Connect the output line.
There is not input from utility Connect utility power and battery.
power and battery. Contact directly vendor or nearby
UPS is damaged. maintenance shop.
22
Hardware Manual of CMS Mud Logging Unit
23
Hardware Manual of CMS Mud Logging Unit
24
Hardware Manual of CMS Mud Logging Unit
organizations.
1.4 Intrinsic safety (IS)
IS, also known as safe spark type, limits the circuital energy in hazardous area to ensure the safety
of electric equipment. In zone 0, the most dangerous area, only intrinsic safety explosion-proof
technology of Ex (ia) grade is adopted according to IEC regulations.
1.5 Acquisition interface and safety parameters of its isolation node
CAN bus explosion-proof acquisition interface, installed in safety zone, is a relevant equipment of
electrical instrument in dangerous area in intrinsic safety system, used for limiting the circuital energy
in hazardous area to realize explosion-proof function of the equipment in hazardous area.
The highest permit voltage (Um) of isolation nodes: ensure the intrinsic safety performance of the
intrinsic safety terminal at isolation nodes and the highest voltage permitted inputting from the non
intrinsic safety terminal.
The highest output voltage (Um) of isolation nodes: the highest output voltage value within the
range of the highest permit voltage when the intrinsic safety terminal is open circuited.
The maximum output current (Io) of isolation nodes: the maximum output current value within the
range of the highest permit voltage when the intrinsic safety terminal is short circuited.
The maximum external capacitance (Co) of isolation nodes: the maximum external capacitance of
the intrinsic safety terminal in the case of ensuring the intrinsic safety performance.
The maximum external inductance (Lo) of isolation nodes: the maximum external inductance of
the intrinsic safety terminal in the case of ensuring the intrinsic safety performance.
1.6 Composition of the intrinsic safety explosion-proof system
The intrinsic safety explosion-proof system is an integral explosion-proof system. The intrinsic
safety system consists of the acquisition interface and devices in dangerous area. When devices such as
power supply, piezoelectric ceramics, capacitance and inductance, etc. are included in the devices in
dangerous area, they can be used after authentication by explosion-proof security inspection
organizations. And the parameters of security authentication should match the security authentication
parameters of safety barrier. When the devices in dangerous area satisfy the condition (<1.2V, <0.1A,
<25mW, <20uJ) and contain no energy storage elements such as contact switch, thermocouple, thermal
resistance, light emitting diode and bridge circuit and so on, they belong to simple devices without
further authentication and can be directly connected into intrinsically safe circuits.
The installation, use and maintenance of CAN bus explosion-proof acquisition interface should
comply with the related clauses of Safety Regulations of the Peoples Republic of China for Electric
Appliance in Explosive Hazardous Areas.
25
Hardware Manual of CMS Mud Logging Unit
technology and field bus technology, which conform to the development trend of the latest technology.
2.2 Compliant with the standardized/open international standards
Comply with the international standard IEC62026-3 of CAN/DeviceNet and provide standard
software support of OPC (ole for process control). The module series of standard protocol and
standardized controlling software components make it convenient for users to posses open environment
with multiple suppliers so as to break equipment supplier monopoly on software or hardware price and
freely select standard-compliant products of high cost performance. System integration suppliers no
longer need to compile various device divers, while the equipment manufacturers only need to provide
an OPC and dont need to compile various divers for different applications, thus system cost is greatly
reduced and composition of the highly networked and decentralized open computer measurement and
control system is simpler, more convenient and more flexible.
2.3 Remarkable performance
Ultra-low power consumption makes high reliability possible: drift of the conventional analog
circuit can be avoided using the method with no movable parts, low power consumption, full-digital
and programmable technology to replace the conventional potentiometer adjusting zero and full degree.
And the ultrahigh precision and reliability are ensured in the full measuring range.
The user programmable technology realizes one unit with multiple purposes: the three ports of
input signal, output signal and power source are isolated, making up the full floating system. It is not
necessary to worry about the complex electromagnetic interference, common mode interference and
environmental condition in industrial fields. The treatment of field problems is greatly simplified and
the fault point can be isolated. The possible fault will be isolated at a signal point (not on a multi-point
card or in a larger system) to avoid influence on the whole system due to the fault of one point. Even in
the case of such expected events as lightning stroke, the large-scale paralysis of the system can be
avoided to the maximum degree.
2.4 Complete species and strong functions
Acquisition interface serialization and the function of signal isolation, power distribution,
amplification, modulation and conversion have covered the most extensive demand in process control
and simplified design. The embedded real-time operating system is adopted to improve the real-time
performance, reliability and scalability of the system and support complicated algorithms. The mature
and reliable multitask real-time kernel can be used to simplify the tasks of complex process and tight
schedule and provide applications such as field bus node configuration management, parameters
calibration and fault diagnosis.
2.5 Wide voltage range
Wide voltage range of power source: 15-25VDC (40mA @24VDC).
2.6 Wide-spread applications and applicable to hazardous areas
SK-9N21/11 CAN bus explosion-proof acquisition interface has increased-safety aluminum-alloy
shell with protection ability of IP65 and can be installed in hazardous areas.
2.7 High cost performance
Field signals can be transmitted to the controller directly in the form of digital signals through the
interface, instead of passing through a large number of signal input and output cards. The intermediate
26
Hardware Manual of CMS Mud Logging Unit
links of signal transmission will be saved and heavy equipment investment can be saved for users who
need intrinsic safety explosion-proof function (for example, the input process of traditional analog is
that the analog signal after passing through the isolation safety barrier is first modulated into digital
signal, then demodulated into analog signal after isolation, outputted into the analog-to-digital converter
of the subsequent DCS system, finally converted into digital signal. With a lot of signal conversions
involved, precision loss is likely to occur). When the digital interface of the safety barrier can be
interoperated with various controllers reliably, the acquisition interface with CAN bus will become the
mainstream of the market and be the updated product of the traditional safety barrier. An integral
solution of the minimum cost for field isolation (explosion-proof) and signal regulation directly
connecting with industrial computers or PLCs, DCS to reduce the intermediate input and output cards
and provide OPC SERVER or other drivers.
2.8 Authoritative identification
Pass the safety certification of national instrument explosion-proof inspection station NWPSI
(international explosion-proof professional association members)
27
Hardware Manual of CMS Mud Logging Unit
Field installation and maintenance should comply with the caution of open the cover after power
off. The maximum surface temperature of the shell is less than 75 ;
The outer diameter of the guiding cable sheath should be f 10- f 12mm. While using the crimping
nut should be tightened to make the inner diameter of the seal ring hug the cable sheath firmly. The
aged cable sheath of the seal ring needs to be changed in time;
Explosion-proof shell must be grounded according to the standard;
CAN/Device Net field bus cable should comply with the relevant standards. The number of nodes
of each bus is not more than 64 and the total length of the main line is not more than 500m. The
outer diameter should be f 10- f 12mm.
For external structure diagram, refer to section V.
The explosion-proof box cover should not be opened rashly. If the built-in isolation nodes need to
be replaced, the cover should be opened softly to avoid damaging the box cover and paint film;
When the intrinsic safety inlet line port of the device is superfluous or not used, it should be
covered using the plastic protecting cap;
Attentions for maintenance: due to compact structures and high requirements of explosion
protection, when product failures are found, the explosion-proof box cover can be opened after
power off, and then the corresponding failure isolating node will be dismounted and replaced by a
new isolating node, which will shorten the maintenance time effectively;
Attentions for wiring: due to the high requirements of explosion protection, if no attention is paid
to the essentials for installation and wiring such as wiring, wire stripping, the inner diameter of
cable compacting seal ring and the end position of the cable sheath and so on, the explosion-proof
and seal requirements cant be reached even the wire has been probably connected. Therefore,
good understanding of the correct essentials for wiring is very important. Its essentials: the inner
diameter of cable compacting seal ring must be consistent with the outer diameter of the cable
sheath, where, 1mm allowance is permitted. When stripping the plastic sheath of the cable, the
mouth of the sheath should be on the same vertical section without laceration to ensure the external
ring of the rubber seal ring to press on the intact cable sheath completely. During installation, try to
avoid placing the nameplate in the position difficult to show the name plate, such as against wall,
etc.
CAN
Inlet and outlet of CAN bus shield Interface of sensor channel
cable
Figure 3-1 External appearance and internal structural diagram of SK-9N11 series single-
channel CAN bus explosion-proof acquisition interface
28
Hardware Manual of CMS Mud Logging Unit
Encapsulated CAN bus isolation node Card connecting to CAN bus shield cable
Figure 3.2 External appearance and internal structural diagram of SK-9N21 series multi-channel CAN
bus explosion-proof acquisition interface
Attention:
For the input of IS5241-EX encapsulated analog signal, IS5216/B-EX encapsulated switch
signal (pump stroke), IS5216/C-EX encapsulated switch signal (drawwork) and IS5216/D-EX
encapsulated switch signal (flow), definitions on the output terminal wiring are different for
the four kinds of CAN bus isolation nodes, nodes in different channels cant be replaced at
will and only the same kind of nodes can be exchanged.
To ensure consistence of the internal wiring circuit board between SK-9N21 multi-channel and SK-
9N11 single-channel CAN bus explosion-proof acquisition interfaces, standard configuration will be
provided for the SK-9N21 multi-channel CAN bus explosion-proof acquisition interface of Shenkai if
no special requirements are proposed by the user: 8 two-wire IS5241-EX encapsulated analog signal
channels, 1 IS5216/C-EX encapsulated switch signal input (drawwork) channel and 3 IS5216/B-EX
encapsulated switch signal input (pump stroke) channels for the drilling platform area; 8 two-wire
IS5241-EX encapsulated analog signal channels and 4 IS5216/B-EX encapsulated switch signal input
(pump stroke) channels for the inlet and outlet areas. For the SK-9N11 single-channel CAN bus
explosion-proof acquisition interface, only 1 three-wire IS5241-EX encapsulated analog signal channel
is provided to connect three-wire analog sensors.
29
Hardware Manual of CMS Mud Logging Unit
30
Hardware Manual of CMS Mud Logging Unit
5241-EX
Analog signal 4-20mA input type CAN/Device Net bus signal output intrinsic safety isolation
nodes provide isolation distribution. The input is 4-20mA analog signal of single-channel intrinsic
safety two-wire system, the output digital signal of DeviceNet protocol, the current unit uA and the data
type 16bits integer. The number of nodes for each segment of bus is not more than 64. For technical
parameters, see Table 3-2.
Table 3-2 Technical parameters table of 5241/-Ex isolation barrier
No. Item 5241-Ex technical parameters Remarks
1 Explosion-proof symbol [Exia]IIC
2 The highest permit voltage: Um 250Vac
3 Safety parameters 28V, 300, 93mA
4 NEPSI authentication parameters Uo=28V lo=93mA
Co=0.083uF Lo=165mH
5 Channel number 1
6 Wiring system 2/3 wire system *
7 Accuracy 0.1%F.S *
8 Distribution voltage When the current is 20 mA, the distribution *
voltage15V.
9 The output signal CAN bus data output *
10 Temperature drift 0.01%F.S/C *
11 CAN communicator 1 *
12 Rate of CAN communication port 125K(bps) *
13 Power supply Voltage: 15-25Vdc (55mA@24Vdc) *
14 Protection capacity of shell: IP65 Encapsulated type
XIV Wiring
Instructions on connection terminal: according to the standard regulations recommended by the
international ODVA (Open DeciceNet .Vendor Association), the color code and definition of
CAN/DeciceNet bus cable are shown in Table 3-3.
Table 3-3 The wiring table of CAN bus explosion-proof acquisition interface
Terminal No. Terminal definition Color code
CAN 1 CAN-H High signal White
Bus cable 2 CAN-L Low signal Blue
3 V+ Positive power supply Red
4 V+ Negative power supply Black
5 END Shield Shielding wire
31
Hardware Manual of CMS Mud Logging Unit
32
Hardware Manual of CMS Mud Logging Unit
Figure 3-3 Position of CAN acquisition adapter card inside the collector
A 125 resistance is set on each CAN socket of the adapter card. CAN signal is output through
33
Hardware Manual of CMS Mud Logging Unit
Connect CAN bus cable here CAN bus signal output to collector here
35
Hardware Manual of CMS Mud Logging Unit
The red line and black line in the CAN bus cable are a group 24V power supply wires for all
devices on the CAN bus and they are connected to + (red line) and - (black line) of 24V/4A
switching power supply respectively. The white line and blue line are a group digital signal wires
for all devices on the CAN bus and they are connected to Pin 7 (white line) and Pin 2 (blue line) of
DB9-core socket at the back of SK-3F02 auxiliary unit respectively. The exposed shield line is
connected to Pin 5 of DB9-core socket.
SK-3F02 auxiliary unit transmits CAN_H and CAN_L digital signals from the bus cable to
CAN acquisition adapter card through the connected DB9-core socket and multi-core cables
(Figure 3-9) between acquisition adapter cards inside the collector.
Figure 3-8 CAN bus signal interface at the back of the collector
The application example of SK-9N11/21 series CAN bus explosion-proof acquisition interface is shown
in the following Figure 3-9.
36
Hardware Manual of CMS Mud Logging Unit
SK-8J06 and SK-9N01 make up the bus drawworks isolation sensor. SK-9N01 is CAN bus
drawworks isolation barrier and its connection terminals are shown in Figure 3-4.
SK-8B06FG and SK-9N02 make up the bus pump stroke sensor and table speed sensor. SK-9N02
is CAN pump stroke isolation barrier and its connection terminals are shown in Figure 3-4.
37
Hardware Manual of CMS Mud Logging Unit
After equipped with SK-9N03, various 4-20mA analog sensors make up the corresponding bus
sensor. SK-9N03 is CAN bus isolation barrier of 4-20mA analog input with the types of two-wire
system and three-wire system. Its connection terminals are shown in the Figure 3-6 and Figure 3-7.
38
Hardware Manual of CMS Mud Logging Unit
the coding or pulse signals for direction judging, for example, drawworks and is commonly known as
the drawworks node.
For the bus box, the airtight, water-proof, anti-corrosive and explosion-proof design is adopted and
the sensor output is intrinsic safety signal.
The CAN field bus system consists of CAN bus sensor node, backbone cable and matched
resistance of the terminals and all the sensors are connected by a four-core cable to accomplish the
transmission of information required.
XVI.3 Parameters
+10%
Working voltage: 24VDC -20%
39
Hardware Manual of CMS Mud Logging Unit
40
Hardware Manual of CMS Mud Logging Unit
adopting the mounting hole attached to the cabinet (you can see four mounting holes of 6mm in
diameter after opening the explosion-proof shell). It can be also installed or hoisted by adopting the
mounting hole on the mounting board and can be installed by adopting C-type clamp as well, shown in
the following Figure 3-10.
Anti-explosion of
SK-9N05 CAN bus
PG incoming terminal
41
Hardware Manual of CMS Mud Logging Unit
42
Hardware Manual of CMS Mud Logging Unit
43
Hardware Manual of CMS Mud Logging Unit
44
Hardware Manual of CMS Mud Logging Unit
45
Hardware Manual of CMS Mud Logging Unit
of bus or overtime of some sensor. In this case, the communication is good at times and bad at
other times. When the overtime occurs to a sensor, check the plug of the corresponding node,
make sure the wire head screws are tightened and eliminate troubles, if any.
XVI.10 Protection class of bus connector
The protection class of CAN bus connector is IP65 and the connectors can be plugged for
10000 times.
It is found the air-tightness is bad in actual applications, which is due to unfastened field bus
and frequent move. The dirt such as oil sludge and sediment load etc. in the well site enters the
sealing parts of socket connectors, giving rise to the decrease in protection class of connectors.
XVI.11 Problem about fuse of CAN node
CAN nodes provided by Shenkai Company meet explosion-proof requirement. To meet the
compulsory explosion-proof regulations, three fast-acting fuses are installed inside the node and
arbitrary change in their specs is not allowed. It is not allowed to prevent fuse failure by increasing
the current spec. of fuse without paying due attention to the possible explosion accidents caused
by dangerous gas.
Due to the fact the equivalent parameters of resettable fuse cannot meet CAN communication
requirements, the fuse cannot be used on the CAN node.
Before new technology that can resolve this problem appears, users are suggested to pay
attention to the following points:
After erecting the CAN bus sensor system and before powering on the CAN bus, first check
bus insulation and power on only when it is normal.
Try to avoid replacing CAN nodes under electriferous conditions. When it is impossible to
avoid the above, do not insert before alignment of locating slots of the socket connector. In
this way, fuse failure caused by the surge current generated due to forced insertion to wrong
pins can be avoided.
It is not allowed to open the cover of CAN node box. For such repairs, Shenkai Company
provides special services upon request by users.
Before connection, socket connectors shall be protected with care to avoid sticking to
conducting fluid such as mud fluid and rain. Clean and dry connectors stuck with mud fluid
and rain.
46
Hardware Manual of CMS Mud Logging Unit
Grounding terminal
Figure 1-1 Grounding terminal inside the rear cabin of the mud logging unit
Grounding terminal
47
Hardware Manual of CMS Mud Logging Unit
Figure 1-2 Grounding terminal on the cabin of the mud logging unit
Water-supply pipeline
Drainage pipeline
Warning
The grounding device is an extremely important safety measure, and it should be
checked regularly. When its in normal operation, it should be checked and tested once
half a year to check whether the conductor is broken and the connection is reliable.
48
Hardware Manual of CMS Mud Logging Unit
grounding, otherwise, the capacitance coupling effect will occur on the signal
cable, and the interference signal will enter the inside of the logging unit using
coupling capacitance.
Attention:
A simple judging method for the failure of the insulating arrestor: disconnect external
wiring and test using insulating megger of 1000V. It is qualified if the reading is greater
than 500M.
49
Hardware Manual of CMS Mud Logging Unit
corresponding electric pulse signals. The corresponding direction of angular displacement and
changing value can be obtained after the signals are sent into the instrument for identifying and
processing. Changes in hook height during drilling can be obtained through calculation, thus the
current drilling depth can be obtained.
Technical indicators
Working voltage: 9VDC
Output signal: 1-3mA (NAMUR signal)
Working temperature: -40-+85
The maximum rotation speed: 1250rpm
The tooth number of the coded disk: 12 teeth
Explosion symbol: Exia II BT4
Explosive-proof certification number: GYB00562
Installation and connection
Installation
Installing position: it can be installed on both ends of the drum shaft of drawworks, but the
sequence of the output phase is opposite. To determine the shaft direction, the drawwork backward
switch settings are available in the software. There is a guard shield on the outmost side of the
drawworks shaft end face. When the length of the guard shield is less than that of the sensor, if the
sensor protrudes over the length of the guard shield after installation, it is suggested to move the
guard shield outwards or work a pup joint to connect the sensor outside the shield.
Installation procedures: First, dismantle the guard shield on the drum shaft end face and
pneumatic joint of the gas-guide tap, and connect the G3/4 tube teeth of this sensor. Second,
connect the gas-guide tap to the sensor and then assemble the guard shield (Figure 3.1-1).
Attention:
The fixed stainless frame and the pneumatic pipeline clamp must be connected firmly;
otherwise it may cause sensor line broken during high speed running of the drawworks.
50
Hardware Manual of CMS Mud Logging Unit
51
Hardware Manual of CMS Mud Logging Unit
52
Hardware Manual of CMS Mud Logging Unit
8B06FG16.2mm
The maximum working frequency: 100Hz
Protection class: IP67
It has the functions of polarity and short circuit protection.
Installation and use
Installation method
Pump stroke sensor:
Installed on the pump rod (Figure 3.2-2): Place the fixed clamp of sensor in the suitable
position, and adjust the fixed nut of sensor to make the sensing face of sensor nearly parallel
to the measured end. Adjust the positions of the sensing face of sensor and the sensing
surface of pump rod to make their distance within 32.4mm (8B06F) /16.2mm (8B06FG);
Installed on the belt pulley (Figure 3.2-3): Weld a 30x30mm iron sheet of right angle to
the belt pulley, with its end face nearly parallel to the end face of sensor. Adjust the fixed nut
of sensor to make the distance between iron sheet and end face of sensor within 32.4mm
(8B06) /16.2mm (8B06FG).
Attention:
Align the inductive end face of the sensor with either of the two ends of the pump rod. It is
forbidden to align it with the intermediate position of the pump rod; otherwise double
times of pump stroke will be measured. As the installing positions of sensors are
different, the pumping speed ratios are different, if it is installed on the pump rod, the
pumping speed ratio is 1:1; if it is installed on the belt pulley, the pumping speed ratio
can be obtained from the division of two parameters after querying the relative
parameters of the mud pump (or the pumping speed ratio is obtained through manually
measured pump strokes divided by the measured value of sensor), then input the
pumping speed ratio (For the input method, see software part)
53
Hardware Manual of CMS Mud Logging Unit
Figure 3.2-2 Schematic diagram of installing pump stroke sensor on pump rod
Figure 3.2-3 Schematic diagram of installing pump stroke sensor on belt pulley
54
Hardware Manual of CMS Mud Logging Unit
Connection
The pump stroke sensor signal output line of CAN bus type is equipped with a four-core
aviation plug. Connect the four-core hole plug of the pump stroke/table speed sensor signal output
line to the four-core needle socket equipped in the 9N21 interface box and screw it up.
Pin definition of aviation connector: 1, signal (orange); 2, null; 3, +9VCD (red); 4, shielding
layer.
55
Hardware Manual of CMS Mud Logging Unit
56
Hardware Manual of CMS Mud Logging Unit
signals. Electronic circuit will amplify the signal outputted by the electric bridge and convert it
into current signal of 4-20mA for output.
Technical indicators
Measuring range: 0-1x105 or 0-80x106Pa
Output: two-wire system 4-20mA
Power supply: 24VDC 4V
Output limitation: when the sensor is over-voltage, the internal current limiter will limit
the output current below 25mA.
Temperature range: working temperature of sensitive element: -50-+125
Working temperature of the electronic components: -40-+85
Humidity range: 0-98% relatively humidity
Measuring range and zero point: internally adjustable, adjusting range: 3%
Performance indicators: accuracy (including linear, repeatability and the comprehensive
error of return difference) grade 0.2.
Linearity: 0.15% of the measuring range
Repeatability: 0.1% of the measuring range
Anti-hazard classification: ia II CT5
Explosive-proof certification number: GYB02139
Installation and wiring
Installation requirements
Select a good installation site convenient for maintenance and operation, and avoid harsh
environment causing damage to the sensor and affecting the measurement. Sensors of different
types are installed in different places on drilling site. The installation requirements are as follows:
There is enough space around, convenient for maintenance and correction;
Not directly exposed to strong heat source and sunlight.
Places not easy to be collided;
Convenient for wiring and installing.
Installation method
Connect the quick coupler of hook weight sensor assembly with the quick coupler of sensor
of derrick deadline anchor (Figure 3.3-1). If the couplers are not compatible, you can dismantle
the quick coupler of sensor of derrick deadline anchor and replace it with the one manufactured by
our company.
57
Hardware Manual of CMS Mud Logging Unit
Figure 3.3-1 SK-8Y21A Schematic diagram of installing hook weight pressure sensor
Wiring
The transmission line should not pass through the conduit or open wire trough
together with other power lines and it should not pass through the neighborhood of
high power equipment either.
It is forbidden to use megohm megger to check insulation. As the sensor adopts
capacitance coupling grounding, only the insulation resistance instrument with the
voltage not more than 100V can be used to check insulation resistance.
Insert the three-core hole plug of the hook weight sensor signal output line (black)
into the three-core needle socket corresponding to 9N21 and screw it up.
Pin definition of aviation connector: 1, shielding layer; 2, +24VCD (red); 3, signal (orange).
Use and operation:
Checkup
It is unnecessary to adjust zero point and measuring range
after leaving factory. When checking up regularly,
if correction is necessary, demount the screws of wire holder,
and unscrew the outer casing for adjustment (Figure 3.3-2).
Figure 3.3-2
Adjustment
It is used to adjust the potentiometer of measuring range continuously, located on the
component side of the circuit and labeled with S, as shown in the right figure. The set screw on
the potentiometer can be rotated 25 cycles, and it will be ineffective when rotating more than 25
cycles.
58
Hardware Manual of CMS Mud Logging Unit
XIX.4 SK-8Y3XA series pressure sensor (stand pipe pressure and casing
pressure)
It is used for measuring pump pressure and casing pressure.
Overview
SK-8Y3XA no-cavity pressure sensor can be used to measure the pressure of viscous media.
Because the sensitive elements of the sensor adopt hard membrane structure, it has the functions
of impact resistance and abrasion resistance when contacting with the measured medium directly.
In addition, adopting ion beam deposition technique makes the sensor have features of high
precision and working stably in harsh environment for a long time.
Technical indicators
Measuring range: 40MPa (8Y34A, standpipe pressure sensor), 60MPa (8Y36A, casing
pressure sensor)
Comprehensive accuracy: (nonlinear, lag , repeatability) 1% FS
59
Hardware Manual of CMS Mud Logging Unit
gasket of f 20
There is another 1 1/2" tee available for users to select according to rig requirements.
60
Hardware Manual of CMS Mud Logging Unit
Figure 3.4-1 Schematic diagram of installing unthreaded hole of Sk-8Y34A standpipe pressure sensor
61
Hardware Manual of CMS Mud Logging Unit
Figure 3.4-2 Schematic diagram of installing threaded hole of Sk-8Y34A standpipe pressure sensor
After the installation of an accessory mentioned above is finished, you should set the
combined gasket of 20 on the sensor and screw the sensor in the threaded hole of the above
accessory and tighten it. Insert the three-core hole plug of the casing pressure sensor signal output
line (black) into the three-core needle socket corresponding to 9N21 and screw it up.
Installation method of 2" threaded pup joint: After selecting compatible threaded hole on
the standpipe, clean the threaded hole first, and then wrap the screw thread of the pup
joint with pipe thread seal tape and screw the pup joint in the threaded hole of standpipe
and then tighten it with a pipe wrench.
Installation method of welded pipe: before installation, find a flat area on the standpipe,
cut a hole of 18 using gas-cutting method, then weld the welded pipe with standpipe
firmly by a professional welder.
Installation method of 2" tee: First dismount the pump pressure meter on the standpipe,
wrap the screw thread of the tee with pipe thread seal tape and screw the tee in the
threaded hole of standpipe and then tighten it with a pipe wrench; subsequently, wrap
the screw thread of the pump pressure gauge with pipe thread seal tape and screw the
pump pressure gauge in the threaded hole of the tee and then tighten it with a pipe
wrench.
Installation method of M201.5 tee: it is used when both drilling and logging need to
install sensors at the same time. It can be installed on the three accessories above-
mentioned by screwing the thread of the tee into its threaded hole.
Installation method of 11/2" tee is the same as that of 2" tee.
Casing pressure sensor (SK-8Y36A)
Generally, a standby mouthpiece is available near the casing pressure gauge of the choke
manifold, usually it is plugged with a bulkhead. To install the casing pressure sensor, you only
need to dismantle the bulkhead and then install the sensor. If there is no such a mouthpiece, you
should install an accessory selectively (the installation method of the accessory is the same as that
mentioned above). After the installation of an accessory mentioned above is finished, you should
set the combined gasket of 20 on the sensor and screw the sensor in the threaded hole of the
above accessory and tighten it. Insert the three-core hole plug of the casing pressure sensor signal
output line (black) into the three-core needle socket corresponding to 9N21 and screw it up.
Warning
As the sensor and its joint shall be subject to huge pressure when the drilling pump is
running, if welded joint is adopted for installation, professional welders are required.
After installation completes, a pressure test will be made according to the pressure value
of nominal full measuring range of different sensors.
62
Hardware Manual of CMS Mud Logging Unit
63
Hardware Manual of CMS Mud Logging Unit
Attention:
For AC variable frequency drilling rigs, the current intensity in the power cable doesnt
present linear increasing and decreasing with changes in torque, therefore, SK-8N07G
electric torque sensor cant measure torque of the rotary table of the variable frequency
drilling rig.
64
Hardware Manual of CMS Mud Logging Unit
In the course of drilling, the working status of downhole tools and changes of formations can
be reflected correctly by using rotary table torque sensor to measure changes in driving torque of
the rotary table. Such changes as drill wear, cone bite or drop, drill stem blocked or broken,
hardness of formation will cause changes in driving torque of the rotary table. Therefore, it is
helpful to know downhole working status using the rotary table torque sensor to correctly measure
and display the rotary table torque. Once any accident is likely to occur, the corresponding
measures can be taken as soon as possible to avoid accident occurrence.
In the course of drilling, the drilling tool is driven by the rotary table to realize drilling. At the
same time, the drilling tool will generate an opposite torque on the rotary table with value equal to
and direction opposite to the driving torque, giving the rotary table a trend to rotate reversely.
There are many terminal strands around the rotary table to fix it. Therefore, the terminal strands
will be acted by a thrust, with value directly proportional to that of table torque, caused by the
reverse rotation of rotary table. Based on this mechanics theory, place a pressure transmitter
between the rotary table and the terminal strands. The pressure transmitter will convert the acting
force of terminal stands into oil pressure; then the table torque sensor will convert the oil pressure
signals transmitted by the pressure transmitter into electrical signals. The intensity of electrical
signal can reflect changes in driving torque of rotary table. Electrical signal is then transmitted to
the secondary instrument or computer interface to display and acquire information on driving
torque of the rotary table.
The composition of SK-8N01G rotary table torque sensor system is shown in Figure 3.6-1,
including pressure transmitter (1) four-way joint, (2) pressure sensor, (3) pressure gauge, (4) as
well as high pressure hose. The high pressure hose that needs to be dismantled frequently is
connected with the four-way joint through a quick coupler so as to be convenient for being
dismantled and assembled. The pressure oil outputted from the sensor will flow into the four-way
joint where an orifice plug (6) is installed to reduce the impact of inputted oil pressure.
65
Hardware Manual of CMS Mud Logging Unit
66
Hardware Manual of CMS Mud Logging Unit
of the rotary table. Similarly, unscrew the terminal strand, set the rubber gasket, and screw the
three terminal strands with similar forces, and then connect the sensor, pipelines and four-way
joint. Fix the pressure gauge on the appropriate position of the derrick.
Figure 3.6-2 Schematic diagram of installing pressure transmitter and rubber gaskets
Figure 3.6-3 Schematic diagram of installing pressure transmitter and terminal strands
Attention:
To enhance the test accuracy, before installation, it is necessary to apply a coat of thread
lubricant used for drill pipe on the surface of the steel beam supporting the rotary table
to reduce the friction resistance between the rotary table and the steel beam surface.
It is necessary to prevent air from entering the oil system such as pressure transmitter,
high pressure hose and manometer.
Air must be vented once it enters the system. The operating procedures are: Unscrew the gas
relief screw (8) (Figure 3.6-1) on the pressure transmitter, dismantle the protective casing on the
oil injecting quick coupler (7) and connect the oil injecting quick coupler with the quick coupler
on the filling pump; at the same time, place all lines and elements in this oil circuit in positions
lower than the pressure transmitter, and then inject pressure oil from the oil injecting quick coupler
67
Hardware Manual of CMS Mud Logging Unit
to vent the gas contained in the oil circuit out of the cavity of pressure transmitter box through the
gas relief screw on the pressure transmitter. When all air is vented and there is pressure oil leaked
out, stop injecting oil immediately, screw up the gas relief screw, dismantle the oil injecting line
and then connect the protective casing with the oil injecting quick coupler.
During drilling, when it is required to test the driving torque of rotary table, the pressure
transmitter must be pressed tightly by the terminal strands of rotary table. Before the rotary table
starts to drive, it is necessary to keep a pre-pressure of 0.3Mpa (you may observe the reading of
the manometer (4) connected with the pressure transmitter) inside the oil cavity of the pressure
transmitter. To prevent the pressure transmitter from loosing, fasten the wire rope (10) on the
handle of pressure transmitter to a suitable position on the terminal strand.
Connection
Two-wire CAN bus analog sensor signal output line is equipped with three-core aviation
plug. Insert the three-core hole plug of the rotary table torque sensor signal output line (black) into
the three-core needle socket corresponding to 9N21 and screw it up (Figure 3.6-4).
Pin definition of aviation connector: 1, shielding layer; 2, +24VCD (red); 3, signal (orange).
Figure 3.6-4 Schematic diagram of installing SK-8N01G rotary table torque sensor
Common trouble diagnosis and elimination
If no signal is available in the operation, first check the reading of the pressure gauge. If
there is no reading in pressure gauge, check whether the terminal strand is loosening or
not. If the reading of the pressure gauge is normal, check the reading of the pressure
transmitter to further eliminate the system troubles.
Oil leakage of the oil system may also result in no signal or incorrect signal in torque. It
must be eliminated.
68
Hardware Manual of CMS Mud Logging Unit
Maintenance
During drilling, when it is required to test the driving torque of rotary table, the pressure
transmitter must be pressed tightly by the terminal strands of rotary table. Before the
rotary table starts to drive, it is necessary to keep a pre-pressure of 0.3Mpa (you may
observe the reading of the manometer (4) connected with the pressure transmitter) inside
the oil cavity of the pressure transmitter.
To prevent the pressure transmitter from loosing, fasten the wire rope (10) on the handle
of pressure transmitter to a suitable position on the terminal strand.
The pressure oil should be filled frequently.
69
Hardware Manual of CMS Mud Logging Unit
cable and coupler of the sensor on the longeron or the derrick with lead wire (Figure 3.7-1 and
3.7-2).
Connection
Insert the three-core hole plug of the rotary table torque sensor signal output line (black) into
the three-core needle socket corresponding to 9N21 and screw it up.
Pin definition of aviation connector: 1, shielding layer; 2, +24VCD (red); 3, signal (orange).
To reduce electromagnetic interference, shielding cables should be used as the signal
transmission lines and their shielding layers must be connected soundly with the sensor enclosure
and the earth.
Figure 3.7-1 Schematic diagram of installing pressure transmitter and rubber gaskets
0~100KN
+
F 15~36VDC
100 _
mA
Figure 3.7-2
70
Hardware Manual of CMS Mud Logging Unit
Figure 3.7-3 Schematic diagram of installing terminal strand type rotary table torque sensor
Common trouble diagnosis and elimination
The sensor circuit has the functions of polarity and over-current protection. When the power
polarity of the circuit is reversed, the circuit will not be burnt out, but the output is zero. Therefore,
if the output current is zero, it is required to check whether the signal cable is misconnected or
disconnected, and polarity reversing can also be taken into consideration. If the output current is 2-
3mA or about 28mA, exert pressure on the head of sensor. If the output shows no response, the
sensor fails. You can contact our company or send the sensor to our company for repair.
Maintenance
Sensor bolt should be applied with a layer of grease and should not be washed with water;
Steel wire cable and joint part should not be pulled or twisted with force;
Store it in a dry and ventilated environment when it is not used and power on to check it
frequently;
Calibration of sensor: dismount the socket of the sensor (Figure 3.7-4), connect according
to Figure 3.7-2. When the force acting on sensor is zero, adjust zero potentiometer W105
so that the output current is 4MA0.05MA. Then exert force of 100KN, adjust full range
potentiometer W100 so that the output current is 20MA0.05MA. According to the
above-mentioned method, repeat the operation 1-2 times, and the calibration work can be
finished.
71
Hardware Manual of CMS Mud Logging Unit
72
Hardware Manual of CMS Mud Logging Unit
7 8
9
6
5
4
1 2
3
10 11
12
Figure 3.8-1 Composition of stretching pulley type rotary table torque sensor system
Technical indicators
The range of the output hydraulic signal: 0-6MPa
The outer diameter of stretching pulley: 305mm
Diameter of high pressure oil cylinder: 65mm
The minimum height of sensor: 355.3mm
Working temperature: -30-+80
Nonlinear error: 0.5%
The output signal: 4-20mA/0-6MPa (current)
Connection and installation
Pin definition of aviation connector: 1, shielding layer; 2, +24VCD (red); 3, signal (orange).
According to difference of drilling rigs, there are two modes for installing the stretching
pulley type table torque sensor. In both modes, the sensors are installed on the strained tight side
of the driving chain under stress . As shown in Figure 3.8-2.
Figure 3.8-2 Schematic diagram of installing stretching pulley rotary table torque sensor
Installation of the closed chain case
A great quantity of lubricating oil is available inside the closed chain case due to the
requirements of lubrication and dust prevention. Therefore, when installing the sensor, first drain
all the oil. Open the full-closed chain cover and install the stretching pulley type rotary table
torque sensor on the strained tight side of the driving chain under stress.
73
Hardware Manual of CMS Mud Logging Unit
The direction of driving chain must conform to the steering wheel identification of the torque
sensor. Screw both of two spacing bolts to the lowest positions so that the high pressure hose of
the sensor can be connected with the manual filling pump (using rapid coupler) to inject oil into
the sensor. The stretching pulley type table torque sensor will ascend with the charging of
hydraulic oil. When the stretching pulley contacts the chain slightly, it is required to put straight
the anteroposterior and right-left position of sensor. After confirming that the position is correct,
weld both short and long backing plates on the anchor plate of the chain base. If finding the
stretching pulley is deviated after welding, you can unscrew four bolts on the anchor plate and
then adjust the position; or you can adjust the anteroposterior position of the stretching pulley by
using set screws on both sides of the hanger bracket to make the chain centralized.
After the position of sensor is confirmed to be correct again, fill the senor with oil
continuously. When the chain is tensioned to some degree, it is required to measure the tightness
of the chain. The method is to exert pressure of about 20 kilograms on the upper chain with hand
at the middle point of the center distance of the chain wheel, with its droop of about 20mm being
the best. Spin the spacing screw upwards until it contacts the hanger bracket and then lock the lock
nut tightly. The main function of the spacing screw is that when it is required to supplement oil
after oil leakage occurs in the hydraulic system, it is unnecessary for you to measure the tightness
of the chain again and you can stop charging oil just when feeling that the operation of filling
pump becomes heavier, which indicates that the stretching pulley has reached its original position,
to prevent the chain from being over tensioned. Since the pressure sensor and the filling pump are
to be connected with it during using, you must punch a hole of 27 on the chain cover and thread
the high pressure hose coupler through it with a round nut locked outside tightly; close the chain
cover, fill up chain lubricant, pull out the filling pump and connect the SK-8Y21A pressure sensor
assembly (with three-way quick coupler). Insert the three-core hole plug of the rotary table torque
sensor signal output line (black) into the three-core needle socket corresponding to 9N21 and
screw it up.
Installation of the semi-closed chain case
The installation method of semi-closed chain case is similar to that of closed chain case,
while it is unnecessary to punch a hole on the chain cover. After installation, you only need to
connect the pressure sensor assembly.
Use and operation
Once air enters the hydraulic systems such as high pressure oil cylinder and high
pressure hose, it is required to discharge the air. The operating procedures are: Unscrew the
brass gas relief screw on the high pressure cylinder of the sensor, dismantle the protective
casing on the oil injecting quick coupler (12) and connect the oil injecting quick coupler with
74
Hardware Manual of CMS Mud Logging Unit
the quick coupler on the filling pump. At the same time, place all lines and elements in this
hydraulic system in positions lower than the high pressure cylinder of the sensor, and then
inject hydraulic oil to vent the air contained in the oil circuit through the gas relief screw on
the high pressure cylinder. When all air is vented and there is pressure oil leaked out, stop
injecting oil immediately, screw up the gas relief screw, dismantle the oil injecting line and
then connect the protective casing with the oil injecting quick coupler.
Attention:
The direction of driving chain must conform to the steering wheel identification of the
torque sensor;
The senor should be installed on the strained tight side of the driving chain; otherwise,
the change trend of the torque cant be induced;
It is necessary to prevent air from entering the oil system such as pressure transmitter,
high pressure hose and manometer.
75
Hardware Manual of CMS Mud Logging Unit
Accessory: foldable cover, with two cable inlets of f 22mm that can be opened on both
sides.
Weight: 1.5kg
Installation
The ultrasonic liquid level sensor can be installed on the mud tank whose liquid level is
required to be monitored with two installation modes: gripping type and welding type (Figures
76
Hardware Manual of CMS Mud Logging Unit
3.9-2 and 3.9-3). SK-8C05 ultrasonic liquid level sensor (gripping type) is installed on the
mounting rack or pipe clamp of the sensor. For SK-8C05 ultrasonic liquid level sensor (welding
type), the welding block on the bottom of the mounting rack is welded to the suitable position. The
installation methods of SK-8C05L and 8C05 ultrasonic liquid level sensors are different, while
others of them are the same.
Installation of gripping type sensor:
Manufacture certain amount of angle irons (as per amount of sensors to be installed) first,
whose specification can be customized. Select the mud tank on which a sensor is to be installed.
The installation position should be selected according to principle that not to influence the
pedestrians. Weld one end of an angle iron on the tank surface firmly and then clamp the sensor
installation carrier on the angle iron and tighten it; fix the gripping type sensor on the sensor
installation carrier. Before tightening it, place the sensor to make its bottom sensing face
perpendicular to the tank surface, and then gas-cut a square hole with opening radius at least
greater than the distance of Htan5 (where H is the vertical distance between the probe and the
tank surface, and tan5 is the tangent value of 5 degree) on the tank surface corresponding to the
sensing face of the sensor. Then put straight the sensing face so that the sensing face of the sensor
is at least 25cm away from the highest liquid level or tank surface and tighten the retaining clip.
Insert the three-core hole plug of the ultrasonic liquid-level sensor signal output line (black) into
the three-core needle socket corresponding to 9N21 and screw it up.
77
Hardware Manual of CMS Mud Logging Unit
78
Hardware Manual of CMS Mud Logging Unit
79
Hardware Manual of CMS Mud Logging Unit
Figure 3.9-4
80
Hardware Manual of CMS Mud Logging Unit
81
Hardware Manual of CMS Mud Logging Unit
If it is required to change the saved checkup value, first adjust the display to C4 or C20
display status, press 20 key to gradually increase the checkup value and press 4 key to
gradually decrease it. When the displayed checkup value rolls to the required value, stop pressing
the key. After displaying for 6s, it will automatically restore to the operation mode. In the course
of checkup, keep pressing the key and the display will roll quickly; release the key when reaching
the required value.
Blind area (Figure 3.9-9)
The blind area is generally used to ignore the area in front of sensor, here various false
echoes will interfere in the true echoes and accordingly affect the true vale. The blind area
starts to count outwards from the sensing surface and the minimum value of blind area is
0.25m (0.82ft) but this value may increase due to the expansion of blind area.
To change the saved value of blind area, first adjust the display to bL display status,
press 20 key and the value of blind area will increase; press 4 key and the value of blind
area will decrease. When the displayed checkup value rolls to the required value, stop
pressing the key. About 6s later, the display restores to operation mode automatically.
82
Hardware Manual of CMS Mud Logging Unit
Interference resolution of stirrer: distinguish the interference between stirrer blades and the
surface of container material (or target) in the course of rotating.
Filter: distinguish the interference between the false echo from optical and acoustic noises
and the surface of container material (or target).
Failure protection clock: create a waiting stage starting from the echo loss or misoperation
status until the default of failure protection time.
Table 3.9-1
Speed of Measuring Identify Filter Failure protection
response response interference clock
1* 1m/min On On 10min
(3.3ft/min)
2 5m/min On On 3min
(499.87cm/min)
3 Response Off Off 3min
immediately
4 0.03m/min On On 10min
(0.1ft/min)
* Original settings.
To change the speed of response, adjust to SP display status, press 20 key and scroll
forwards to display options (1-2-3); press 4 key and scroll backwards to display options (3-2-1).
When the target option is displayed, stop pressing and it automatically returns to the operation
mode after displaying for 6s.
and the system immediately carries out one of failure protection defaults.
83
Hardware Manual of CMS Mud Logging Unit
Table 3.9-2
Failure Default P i Reading value
protection MA MA
FLS
1* Saturation 22 4 HOLD
2 Null 4 22 HOLD
3 HOLD HOLD HOLD HOLD
P-Direct ratio gain
i-Inverse ratio gain
* Original settings.
To change the failure protection default, first adjust the display to FLS display status, press
20 key and scroll forwards to display options (1-2-3); press 4 key and scroll backwards to
display options (3-2-1). When the target option is displayed, stop pressing and it automatically
restores to the operation mode after displaying for 6s.
84
Hardware Manual of CMS Mud Logging Unit
Showing that the echo is incorrect or the sensor is waiting for an effective echo before refreshing
the measurement. Causes:
The measured material or target contacts the sensor surface.
The sensor is too close to the packing opening;
The sensor is not perpendicular to the liquid level;
The liquid level changes too quickly;
The measurement is out of range.
There is foam on the liquid surface;
The vibration amplitude of the fixed support is large.
Liquid level enters blind area.
Appear
LOE/FAULT
View the time adjustment/response speed of the waiting stage.
Maintenance
It is required to keep the sensor clean and avoid water vapor and oil sludge entering the
operation panel. It is usually installed in the sealed protective case and it is not exposed
to outside while working. The protective case can be opened only when checking up and
adjusting.
The sensor should be installed about 0.25m above the maximum liquid level measured.
Otherwise, the liquid will immerse the sensor, which will cause damage to the sensor.
85
Hardware Manual of CMS Mud Logging Unit
The signal cable inlet of sensor should be sealed to avoid water and oil sludge.
Procedures for calibrating ultrasonic sensor:
1) Enter the automatic operation mode after powering on;
2) Press 20mA20 and 4mA 4 touch keys at the same time;
3) C4 is displayed, showing 4mA calibration initialization;
4) Wait for 3s to display the saved value and then press 20mA 20 or 4mA 4 , move upwards or
downwards to select the value you want (=height of mud pit + distance from end surface of
sensor top of mud pit) and release the key;
5) Enter the automatic operation mode after waiting for 6s;
6) Continuously press 20mA20 and 4mA 4 keys twice at the same time until the display
sequence is C4-C20 and release the keys;
7) C20 is displayed, showing 20mA calibration initialization;
8) Wait for display of the saved value and then press 20mA 20 and 4mA 4 , move upwards or
downwards to select the value you want (=distance from end surface of sensor top of mud
pit) and release the keys;
9) Repeat the fifth step;
10) Continuously press 20mA20 and 4mA 4 keys three times at the same time until the display
sequence is C4 C20 bL and release the keys;
11) bL is displayed, showing the initialization calibration of the value of blind area;
12) Repeat the fourth step, but select the required value > 25mm;
13) Repeat the fifth step;
14) Continuously press 20mA20 and 4mA 4 keys four times at the same time until the display
sequence is C4C20bLSP and release the keys;
15) SP is displayed, showing the calibration initialization of speed of response;
16) Repeat the fourth step, but generally select the required value, which is 2.
17) Repeat the fifth step;
18) Continuously press 20mA20 and 4mA 4 keys five times at the same time until the display
sequence is C4C20bLSPFLS and release the keys.
19) FLS is displayed, showing failure protection calibration initialization.
20) Repeat the fourth step and selected the required value, generally 1 or 2.
21) Repeat the fifth step;
22) Continuously press 20mA20 and 4mA 4 keys six times at the same time until the display
sequence is C4C20bLSPFLSFSE and release the keys (This step can be skipped)
23) Repeat the fourth step and initialize the calibration of failure protection lasting time.
24) Repeat the fifth step and set the value you want (select any value in the range of 0-15)
25) Continuously press 20mA20 and 4mA 4 keys seven times at the same time until the display
sequence is C4C20bLSPFLSFSEUN and release the keys;
26) UN is displayed, representing unit setup;
27) Repeat the fourth step and select the needed unit according to requirements;
86
Hardware Manual of CMS Mud Logging Unit
87
Hardware Manual of CMS Mud Logging Unit
The mechanical structure adopts stainless material, thus being capable of working all day long in
open air. The working temperature range is -40-+85. It is
mainly applicable to liquid level measuring in industries such as
oil field, environmental protection, chemical, power and
papermaking and so on. The explosion proof type can be used in
the flammable and explosive places. For operating principle of
sensor, refer to Figure 3.10-1.
There is a group of dry reed tubes and precision resistance
installed inside the test tube of sensor. When magnetic floating
ball outside the tube ascends and descends with the liquid level,
the dry reed tubes at liquid level inside the test tube will be
powered on in sequence to make the resistance value of sensor
change. The converting circuit inside the junction box will
convert the resistance value into current for output.
Main technical parameters
Measuring range: 300-2000mm (4m can be achieved
according to requirements)
Accuracy: 1% FS 25
Power supply: 24VDC, 4-20mA two-wire 3.10-1 Schematic diagram of senor
operating
system
Shell protection: IP65
Range of working temperature: -40-+85
Explosion-proof symbol: flameproof type: dII
BT4 (intrinsic safety ib II CT4)
Explosive-proof certification number:
GYB99421
Installation and use
Installation
Weld the fixed support of sensor to the tank surface
first, and then gas-cut a square hole a little bigger than the
floating ball on the tank surface; put the sensor together
with the floating ball into the mud tank and fix the sensor
with the fixed support. Insert the three-core hole plug of the
liquid level sensor signal output line (black) into the three-
core needle socket corresponding to 9N21 and screw it up
(Figure 3.10-2).
Pin definition of aviation plug: pin 1, shielding layer;
pin 2, +24VCD (red); pin 3, signal (orange).
Adjustment of zero point and full range
3.10-2 Schematic diagram of installing sensor
Connect the current meter in series to the output
3
loop, and put the floating ball at the lowest point to
adjust the zero potentiometer so that the reading of the current meter is 4mA0.02. Put the floating
ball at the highest position to adjust the full range potentiometer. To make the reading of the
current meter is 200.02mA and repeat the operation once again. The set screw is under the
nameplate, marked with Z.
88
Hardware Manual of CMS Mud Logging Unit
3 Maintenance
When the circuit in the test tube is damaged, it can be judged whether that printed board fails
by measuring resistance. The total resistance of the board is 2000. If the resistance is very
small or very large, it indicates that the board fails. And it can be solved through replacing the
printed board. If something is wrong with the transmitter, it can be solved through replacing
the module type of transmitter.
If the liquid level sensor is used in mud tank of oil field, it is required to wash the measuring
rod and floating ball frequently and avoid the mud caking on it to affect the liquid measuring.
Since there is a minisize dry reed switch enclosed with glass in the liquid level measurement
tube of this sensor, it is required to handle it gently. Throwing and knocking sensors is
strongly forbidden. Anti-vibration measures should be taken in the course of transportation,
and it is suggested to put the sensor in the original packing box.
Attention:
Since there is a minisize dry reed switch enclosed with glass in the liquid level
measurement tube of this sensor, it is required to handle it gently. Throwing and
knocking sensors is strongly forbidden.
89
Hardware Manual of CMS Mud Logging Unit
corresponding voltage signals after processing of subsequent circuit. At the same time, take the
voltage signal corresponding to the real-time temperature. Carry out functional operation of these
two parameters to get the real-time electrical conductivity value that is compensated to 25 .
Display this value and convert it into 4-20mA signals for output.
90
Hardware Manual of CMS Mud Logging Unit
if users have further demands for the measuring accuracy, they can calibrate strictly according to
this chapter.
Connection
Pin 2 of three-core hole aviation socket is connected to +24VDC and pin 3 is connected to the
power supply through 250 resistance.
Remarks
Parameter adjusting and inspecting (calibration) of devices must be carried out in the
laboratory environment. Open the cover after power off.
To facilitate explanation, is named key 1, key 2 and key 3.
Before calibration, ensure the probe is connected to the transmitter correctly and +24V power
supply works normally.
During calibration, if the time interval between key strokes is more than 15s, the system will
exit calibration automatically and display the real-time electrical conductivity value.
V-2.0 is the cover of calibration menu. After returning to display V-2.0 when finishing a
calibration, key 3 can be pressed for a short moment to carry out other calibrating
operations.
4mA calibration
4mA calibration and 20mA calibration introduced below are to ensure the precision of
DA conversion. A multimeter displaying over 4.5 digits is needed to carry out this operation.
Select DC current shift of the multimeter, and open the rear cover of the transmitter
of SK-8D08 digital type electrical conductivity sensor. The red detector of
multimeter is connected to Test+, and the black one is connected to TEST-.
Press key 1 for 3s until V-2.0 is displayed.
Press "key 3 for a short moment until 4mA is displayed.
Press key 1 for a short moment, the DA converting data corresponding to the
current output 4mA (types such as d 655) is displayed.
If 4.00mA is displayed in the multimeter, jump to step 8.
Press key 2 for a short moment, the displayed data will flicker by the digit order;
press key 3 for a short moment, the flickering data will overturn from 0 to 9.
The multimeter will display 4.00mA through modifying the data displayed in the
screen.
Press key 1 for a short moment, the sensor will store the result of calibration and
V-2.0 will be displayed.
Press key 1 for a short moment to exit calibration, and the real-time electrical
conductivity value will be displayed.
20mA calibration
91
Hardware Manual of CMS Mud Logging Unit
Select DC current shift of the multimeter, and open the rear cover of the transmitter
of SK-8D08 digital type electrical conductivity sensor. The red detector of
multimeter is connected to Test+, and the black one is connected to TEST-.
Press key 1 for 3s until V-2.0 is displayed.
Press "key 3 for a short moment until 20mA is displayed.
Press key 1 for a short moment, the DA converting data corresponding to the
current output 20mA (types such as E3277) is displayed.
If 20.00mA is displayed in the multimeter, jump to step 8.
Press key 2 for a short moment, the displayed data will flicker by the digit order;
press key 3 for a short moment, the flickering data will overturn from 0 to 9.
The multimeter will display 20.00mA through modifying the data displayed in the
screen.
Press key 1 for a short moment, the sensor will store the result of calibration and
V-2.0 will be displayed.
Press key 1 for a short moment to exit calibration, and the real-time electrical
conductivity value will be displayed.
Read the probe constant J
To calculate the equivalent resistance, it is required to read the value of probe constant J.
Press key 1 for 3s until V-2.0 is displayed.
Press "key 3 for a short moment until rd_J (read J) is displayed.
Press key 1 for a short moment, the probe constant J of the current system (types
such as G405) will be displayed.
Press "key 1 for a short moment until V-2.0 is displayed.
Press key 1 for a short moment to exit calibration, and the real-time electrical
conductivity value will be displayed.
Inspection of calibration effect
To inspect the calibration effect conveniently, SK-8D08 adds a function of inspection using
resistance box to simulate mud environment. This operation only needs a resistance box with its
accuracy being 0.1% and a multimeter displaying over 4.5 digits.
The value of probe constant J of this sensor will be obtained through read the probe
constant J operation.
Calculate the equivalent resistance corresponding to 37.5ms/c, 75ms/c, 150ms/c,
225ms/c and 300ms/cm through formula (J/C) 4. (For example: the value of
probe J is 4050-3/cm obtained through read the probe constant J operation;
calculate the equivalent resistance: (405/300) 4 =5.4 corresponding to
300ms/cm)
92
Hardware Manual of CMS Mud Logging Unit
The resistance box is put through the external ring of the probe through conductor,
and the conductor winds two cycles.
Select DC current shift of the multimeter, and open the rear cover of the transmitter
of SK-8D08 digital type electrical conductivity sensor. The red detector of
multimeter is connected to Test+, and the black one is connected to TEST-.
Press key 1 for 3s until V-2.0 is displayed.
Press "key 3 for a short moment until simul (simulation) is displayed.
Press key1 for a short moment and the real-time electrical conductivity value
(unit: ms/cm; type: F 300.0) will be displayed.
Change the resistance value of the resistance box, and the electrical conductivity
and the displayed data on the screen will change. The specific relationship is given
in Table 3.11-1.
Table 3.11-1
Resistance value of Electrical conductivity (unit: Current value (unit: mA)
resistance box (unit: ms/cm)
)
5.40 300.003 20.000.16
7.20 225.003 16.000.16
10.80 150.003 12.000.16
21.60 75.003 8.000.16
43.20 37.503 6.000.16
Disconnect 0.00 4
If you are not satisfied with the inspection results, you can carry out accurate
calibration according to the relative description of calibration again.
Press "key 1 for a short moment until V-2.0 is displayed.
Press key 1 for a short moment to exit calibration, and the real-time electrical
conductivity value will be displayed.
Take down the multimeter, and cover the back cover.
Installation and use
Installation
Weld the fixed support of sensor to the corresponding tank surface first, and then gas-cut
a square hole a little bigger than the sensor probe on the tank surface; put the lower part
of the sensor into the mud tank completely and fix the sensor with the fixed support;
During installation, the pole should be lowered vertically. The distance between the
liquid level of mud and the probe should be 5cm at least and that between the probe and
the mud ditch should be maintained at least 5cm;
Fix the CAN bus node near the sensor and insert the 3-core hole plug of the signal
93
Hardware Manual of CMS Mud Logging Unit
output line (black) of electrical conductivity sensor into the 3-core needle socket
corresponding to 9N21 and screw it up. Figure 3.11-2 is the result after installation.
Pin definition of aviation plug: pin 1, shielding layer; pin 2, +24VCD (red); pin 3, signal (orange).
Use
After being installed on proper positions, they can be powered on to work;
Since the probe constant J will change due to abrasion of probe or probe being covered
with mud during use, the measurement accuracy can be influenced. Therefore, it is
required to clean the probe carefully and recalibrate the probe constant J regularly
(generally once 5 weeks). Once the probe constant J is calibrated, it is required to read
and record the value of J of current system. When the cumulative deviation of value of J
exceeds 1.00, to ensure the measurement accuracy, please replace the probe and
recalibrate it before bringing it into use;
If the relatively low on-site temperature causes the screen display ambiguous, you can
open the front cover of the transducer carefully after power off and adjust the
potentiometer W1 behind the display panel to make the display vivid.
Remarks
The body of transmitter is made of aluminum alloy but it may be corroded to some
extent if it is used for long time due to the fact that the water quality in well site is
alkaline. It is suggested to enhance external safeguard procedures to prolong its life and
improve its reliability.
Erect cables under the principles not to hinder the field operations of operators in well
site, uneasy to buck or damage, safety and reliability.
When installing and using, users shall comply with requirements in this manual and in
the service manual of safety barrier and related regulations as well in GB3836.15-2000
Electrical Apparatus for Explosive Gas Atmospheres Part15: Electric Installation in
Hazardous Areas (other than coal mines) and GB50058-1992 Code for Design of
Electric Installations within Explosion and Fire Hazard Atmospheres.
Common troubles and elimination methods
Failures Causes and elimination methods
OT_CR is displayed There may be two causes resulting in wrong display: the
temperature of mud exceeds the applicable temperature
of SK-8D08 conductivity senor; the mud conductivity is
beyond the range for measuring conductivity of SK-
8D08 conductivity senor.
The mud temperature suitable for measurement of SK-
8D08 conductivity senor is 10-80.
The mud conductivity suitable for measurement of SK-
8D08 conductivity senor shall not exceed 300ms/cm.
After R_J_C or A_J_C is The cause resulting in wrong display is that the
displayed, J calibration cant be conductivity value of the standard sample mud is too
carried out by pressing key 1. small.
The prerequisite for J calibration is that the conductivity
value of standard sample should be more than 10ms/cm.
The display of conductivity is Install the sensor to a place far away from interference.
94
Hardware Manual of CMS Mud Logging Unit
unstable.
The display of conductivity is The installation of sensor is incorrect or unsuitable.
incorrect. The calibration is incorrect. Calibrate it again.
Others Please consult our company.
Attention:
Pollutants and mud crusts on the probe will influence the accuracy of measurement.
Therefore, after each use, it is required to flush the adherent mud away immediately. It is
not allowed to use a probe with dried mud.
When more than 2 SK-8D08 digital electrical conductivity sensors are installed on the same
mud ditch simultaneously, you should ensure that their probe levels are in the same line and the
distance between them is at least 5cm. If the relatively low on-site temperature causes the screen
display ambiguous, you can open the front cover of the transducer carefully after power off and
adjust the potentiometer W1 behind the display panel to make the display vivid. Since the probe
constant J will change due to abrasion of probe or probe being covered with mud during use, the
measurement accuracy can be influenced. Therefore, it is required to clean the probe carefully and
recalibrate the probe constant J regularly (generally once 5 weeks). Once the probe constant J is
calibrated, it is required to read and record the value of J of current system. When cumulative
deviation of value of J exceeds 1.00, to ensure the measurement accuracy, please replace the probe
and recalibrate it before bringing it into use.
95
Hardware Manual of CMS Mud Logging Unit
line. Their shells are enclosed with insulating materials resistant to high temperature, acid and
caustic and abrasion. The probe of sensor is immersed in the drilling fluid. The AC signals of
20KHZ transmitted in the primary coil will generate induced current in the drilling fluid that
presents closed status. The induced current generated through drilling fluid will be induced to the
secondary coil of the sensor. The magnitude of signal received by the secondary coil is directly
proportional to the conducting power (i.e. electrical conductivity) of drilling fluid. There is an
incorporated temperature sensor (thermistor) inside the sensor, which is used to monitor the
temperature of drilling fluid, correct the electrical conductivity at measured temperature based on
temperature and compensate it to the electrical conductivity of this drilling fluid at 25 . The
electrical conductivity transmitter will reshape, magnify and process the sensor signals and output
standard DC current signals of 4-20mA corresponding to the electrical conductivity.
Technical indicators
Using object: liquid
Measuring range (linear measuring): 0-25ms/cm or 0-50ms/cm can be selected
Output range: 4-20mADC
Power supply 24VDC
Temperature range: working temperature of sensor -30-+70
Humidity range: relatively humidity < 90%
Response time: the response time will be not more than 1s
Measuring accuracy: 1% of full measuring range
Linearity: 1% of full measuring range
Anti-hazard classification: dib II BT4
Installation
96
Hardware Manual of CMS Mud Logging Unit
Figure 3.12-1
Connection of transmitting sensor and the outside (take down the cover of the transmitter and
connect according to Figure 3.12-1)
Connection of transmitter and probe
The probe of sensor is connected to the transmitter using seven-core cable. Label, color and
function are as follows.
Black;
The white line is the outgoing line of the primary coil;
The bare copper wire is shield line;
Red;
The bare copper wire is the outgoing line of the secondary coil;
Brown;
The blue line is the outgoing line of the thermistor.
SK-8D03 and SK-8D04 electrical conductivity sensors can be installed conveniently after
being made as integrated devices. First weld
the fixed support of sensor to the
corresponding tank surface, and then gas-cut a
square hole a little bigger than the sensor probe
on the tank surface; put the lower part of the
sensor into the mud tank completely and fix
Fig. 3.12-2 Schematic diagram of
the sensor with the fixed support. During installing sensor
installation, the pole should be lowered
vertically. The distance between the liquid
level of mud and the probe should be 5cm at
least and that between the probe and the mud
ditch should be maintained at least 5cm. Insert
the three-core hole plug of the casing pressure
97
Hardware Manual of CMS Mud Logging Unit
sensor signal output line (black) into the three-core needle socket corresponding to 9N21 and
screw it up (Figure 3.12-2).
Pin definition of aviation plug: pin 1, shielding layer; pin 2, +24VCD (red); pin 3, signal (orange).
Use and operation
Zero setting
If the zero position deviates when using this unit, adjust the zero position by the following
methods. For the zero setting, it is required to clean the probe head of sensor, then connect to the
power supply and connect the current meter in series. (If you measure the voltage, connect the
load resistance in series and the two ends of resistance are connected to the voltmeter and the
output current value is measured voltage divided by the resistance. It is suggested to use the load
resistance of 100.), and then adjust the zero setting screws on the shell of transmitter so that the
output of transmitter is 4mA.
Range adjustment
The measuring range has been adjusted to the proper position before leaving factory and in
general, uses have no need to re-adjust. But if it is used for a long time, it is adjusted following the
steps below in order to obtain better accuracy;
1) The thermistor is not connected, unfasten pins of brown wire and blue wire,
connect a standard resistance of 100K to the transmitter which is an electrical
conductivity value of 25.
2) Pass through the center hole with a wire and two ends of the wire are connected to the
resistance box to form a ring resistance circuit.
3) Connect the required power supply and connect in series a current meter to the power
supply, used for detection;
4) After finishing the preparations above, first correct the zero position, namely, when the
ring resistance RL=, the output is 4mA; if the zero position deviates, it is required to
adjust the zero setting screws on the shell of transmitter so that the output of transmitter
is 4mA;
5) Connect the resistance box to make the ring resistance R L=1.8, and then the output
shall be 200.16mA; if it deviates, take down the components of circuit and adjust the
marked 3296-type range potentiometer so that the output is 20mA.
6) Repeat steps 4 and 5 until zero position and full range value of output are in the
acceptable range.
Linear test (see test wiring diagram)
1) Relation of output current and conductivity
The relation of electrical conductivity and the output current is linear. The output current I
(mA) and the electrical conductivity will be expressed by the following formula:
98
Hardware Manual of CMS Mud Logging Unit
Figure 3.12-3
2) Corresponding values of output current and ring resistance for checkup
RL I RL
9K 4mA 9K
144 5mA 28.8
72 6mA 14.4
36 8mA 7.2
18 12mA 3.6
12 16mA 2.4
9 20mA 1.8
50ms/cm 250ms/cm
Common trouble diagnosis and elimination
Probe part
Open the end cover of transmitter, check terminals of 1-7 to judge whether the probe is
normal or not. The methods are as follows:
Use resistance shift of multimeter to
measure insulation resistance:
insulation resistance between any of
terminals 1-7 and the aluminum shell
>20M; insulation resistance
between 1 or 2 and 4 >20M; Figure 3.12-4
99
Hardware Manual of CMS Mud Logging Unit
Maintenance
SK-8D03/04 electrical conductivity sensor is composed of two parts: transmitter and probe
with protective cover that can be dismounted. The protective cover can prevent the probe from
unexpected damage and ensure the accuracy of measurement. Therefore, it should be noticed to
install a protective cover on the probe before using it and avoid foreign matter entering the cover
in the course of measuring (such as temperature sensor).
Pollutants and mud crusts on the probe will influence the accuracy of measurement.
Therefore, after each use, it is required to flush the adherent mud away immediately. It is not
allowed to use a probe with dried mud.
Before SK-8D03/04 electrical conductivity sensors are put into use, zero position and full
range should be checked. If necessary, conduct the linear test.
Overview
This sensor is used for measuring the density of drilling fluid of petroleum drilling and it can
also be used to measure the flow rate of liquid, gas, steam and liquid level.
Technical indicators
Working voltage: 24VDC
Working temperature: -40-+80
100
Hardware Manual of CMS Mud Logging Unit
Measuring range: 0-2.5g/cm3
Accuracy: not greater than 0.02g/cm3
Anti-hazard classification: d IICT5
Attention:
When the liquid level of mud fluctuates, both upper and lower flanges must be
immersed in the mud completely. They must maintain vertical and inclination is not
allowed; otherwise the accuracy of measurement will be influenced.
The sensor should be installed at a position where the flow of mud is relatively stable in
the mud pit to ensure the normal work of the sensor.
Adjustment
Zero setting
Put the mud density sensor in the air, adjust the zero setting screws in the transmitter so
that the output current is 4mA, <0.12mA. After zero setting, dont power off immediately; if
the power is turned off 30s later after zero setting, the zero point will restore to its original
value. Please note that zero setting shall be conducted under the conditions that upper and
lower flanges are dry.
101
Hardware Manual of CMS Mud Logging Unit
Gain control
Screw off the end cover of transmitter, insert the imbedded indicating meter into the
circuit board, then put the sensor in the fresh water and connect the power supply; due to the
fact that the density of water is 1, the meter head shall display 40%, the output current signal
is 10.4mA. If the reading shows a relatively large deviation, press the button in the right
lower of display; when HSET text is displayed, adjust the zero setting screws to display the
correct percentage and now the displayed value twinkles, showing the status adjustment. Re-
press the button of display to stably display the digit and finish the adjustment after waiting
for 30s (Figure 3.13-2).
Figure 3.13-2
Test on linearity of sensor (See Table 3.13-1)
If uses want to use a simple method to test the linearity
and full range value of sensor, they can use the checkup
flange (optional parts), take down the protective cover of
sensor and install the checkup flange on the lower flange. Fill
the plastic hose with fresh water, unscrew the air discharge
screw on the checkup flange, and add a certain quantity of
water to make the water spill out from the air discharge screw,
then screw up the screw and clap the plastic hose to drive out
the air bubbles in the hose wall (Figure 3.13-3). Then connect
the power supply and connect the current meter in series to
the output loop (or install the imbedded indicating hand),
change the height of liquid level and you can see the output
signal changes and this change shall be approximately Figure 3.13-3 Schematic diagram
of linearity test
102
Hardware Manual of CMS Mud Logging Unit
conform to Table 3.13-1. For the final debugging, description in clauses 1 and 2 shall prevail.
After finishing the debugging, it is required to take out the embedded indicating meter and screw
up the end cover. For the final debugging, description in clauses 1 and 2 shall prevail. After
finishing the debugging, it is required to take out the embedded indicating meter and screw up the
end cover.
Table 3.13-1
H (mm) 0 300 450 600 750
3
(g/cm ) 0 1 1.5 2 2.5
% 0 40 60 80 100
I (mA) 4 10.4 13.6 16.8 20
Figure 3.14-2 Current transmitting unit Figure 3.14-3 Schematic diagram of installing
temperature sensor
Precautions for installation and use
This sensor is compatible with and can replace the imported temperature sensors of the
same type.
The sensor used for measuring mud temperature can be classified into two types: inlet
temperature sensor and outlet temperature sensor, and their differences lie in external
104
Hardware Manual of CMS Mud Logging Unit
dimensions;
Mud inlet temperature sensor can be fixed inside the mud pit at the inlet of mud pump with
the fixed support.
Common trouble diagnosis and elimination
If troubles occur to the temperature sensor during use, first check the cable for any
disconnection, short circuit and detachment of the connector.
To check for troubles of the temperature sensor, you can use the resistance shift of
multimeter to measure the two ends of the leading wire of Pt100 thermistor. The
resistance values should range between 100-140. Otherwise, the platinum wire is open
circuited or the joint contacts poorly.
If troubles occur to this sensor, it is suggested to send it to the factory for repair.
Maintenance
Clean in time the mud stuck to the sensor, if any to ensure reliable and correct operation
of the sensor.
Cables should be erected under the principles not to hinder the field operations of
operators on well site, uneasy to buck or damage, safety and reliability;
XIX.15 SK-8L03A mud outlet flow sensor
This sensor is used to measure the relative variation of outlet flow rate of drilling mud.
Overview
SK-8L03A outlet flow sensor is used to measure the relative variation of outlet flow rate of
mud. According to the continuity principle and Bernoulli equation of mud and the force analysis
of baffle, the functional relation between the flow rate and the amplitude of fluctuation of sensor
baffle can be obtained. This sensor can linearly reflect the angular
displacement of baffle with the resistance variation of resistor, thus
measuring the relative variation of mud flow rate. Current
transmitting unit is added to the flow sensor of current type, which
will convert the output into current. It has passed explosion-proof
certification.
Technical indicators
Working temperature: -40-+80
Output current: 4-20mA
Variation range of resistance value: 0.5-2.15K
Opening angle of baffle: 0-45
Measuring range: 0-100%. The measuring range can be
changed by changing the mass of the counterweight block of
baffle.
Fig.3.15-1 Outside drawing of sensor
Working voltage: 24VDC
Explosion symbol: Exib II BT5
Features
105
Hardware Manual of CMS Mud Logging Unit
It has good air-tight performance. The sensor uses sealing device at the pulling bar
position of baffle, which solves the problem that the mud enters the electrical and
mechanical transmission parts. It improves the performance and service life of the sensor.
With smaller external dimension, it is convenient for installation (Figure 3.15-1).
Installation
First, select a position for welding the fixed support of sensor. Dismantle the fixed bolts and
rubber gaskets around the sensor and take off the fixed support. Gas-cut an opening in conformity
with the fixed support on the outlet pipe of drilling fluid according to the size of the fixed support,
and then weld all of four borders of the fixed support with the gas-cut opening together; put the
sensor into the mud pipe, set rubber gaskets and spin the fixed bolt tightly. You can also fix the
sensor inside the mud ditch at the outlet of mud with the fixed support. Insert the three-core hole
plug of the flow sensor signal output line (black) into the three-core needle socket corresponding
to 9N21 and screw it up (Figure 3.15-2).
Pin definition of aviation plug: pin 1, shielding layer; pin 2, +24VCD (red); pin 3, signal
(orange).
Attention:
It is advisable that the baffle immergence depth should ensure the baffle is not
obstructed by sedimentary sand, and after installation, you should inspect if the baffle
can swing freely within the pipe space and does not collide with the internal wall of
pipeline. Otherwise the accuracy of senor output signal will be influenced.
106
Hardware Manual of CMS Mud Logging Unit
of mud is very high, when the oscillating arm of sensor rushes to the limit position, you can
increase the balance weight appropriately; if the flow rate of mud is relatively low and the
oscillation amplitude of the sensor oscillating arm is very small, you can decrease the balance
weight accordingly.
Use and operation
The current type sensor is equipped with current transmitting unit inside the sealed junction
box. Its appearance and connection are shown in Figure 3.15-3. Zero point and full measuring
range have been adjusted well before leaving factory. If necessary, ask professionals to adjust
it.
Selection of load resistance RL of current type sensor must meets the following formula:
V - 7.5
RL < - R
20mA
In the formula: VPower
is the supply voltage (V);
RLine is cable resistance
(K); usually RL=250.
Used in explosion-
proof place: the cable
of sensor connects the
isolation barrier
directly. The
distributed
capacitance of cable
0.15f and the Figure 3.15-3 Current transmitting unit
distributed inductance2mH. The cable of sensor is
shielding sheathed cable, with core cross-section > 0.5mm 2. The shielding layer is insulated
from the shell and should be grounded in a safe place.
Common trouble diagnosis and elimination
If the flow sensor has no signal output in normal operation, first check the extension cable for
any breakage or short circuit.
To check for the troubles of 8L03 flow sensor, you can take out the sensor from the mud ditch
and use the resistance shift of multimeter to measure the pins 1 and 3 of the aviation plug.
There should be resistance value of 2.15K. The resistance values between pins 1 and 2 or
between pins 2 and 3 should change in the range of 0-2.15K with changes of baffle angle.
Replace failed varistor, if any, with the varistor of the same specification. If jamming occurs
to the baffle without variations of angle, disassemble the stainless steel cover in the upper of
it to check the internal mechanical parts. After eliminating the troubles of mechanical
transmission parts, add lubricating oil to the moving mechanical parts. For the current type
sensor, if cable connection is normal, disassemble the encloser to check the potentiometer. If
the potentiometer is in good condition, damage of current transmitting unit should be taken
into account.
Method for replacing potentiometer:
Open the protective cover, unfasten the fixed screw of the pinion gear and take down the
pinion gear. After unsoldering the wire head of potentiometer, unfasten the fixed screw
of the potentiometer socket, dismantle the potentiometer socket (with potentiometer) and
take down 3-M3 screw;
107
Hardware Manual of CMS Mud Logging Unit
H2S sensor of Shenkai standard configuration is General Monitors S214, which adopts
metal oxide probe with the continuous service life being about 5 years. Please replace it
in time before the service life is over.
108
Hardware Manual of CMS Mud Logging Unit
Warning
The splash guard should be installed on the sensor probe during use to prevent mud or
other liquid from splashing on the surface of the probe.
Drying agent and protective cover should be installed on the sensor probe when
powering off to stop using, to avoid the probe being damaged by moisture.
109
Hardware Manual of CMS Mud Logging Unit
distributor, which converts one channel of input signal into multiple channels of signal for output.
Rotation speed and torque meters of Varco top drive have occupied their own 0-10V interfaces,
leaving us two 0-20mA interfaces. We can use a 9N21 A-type node for each interface, and connect
pins 1 and 3 at the output of three-core needle socket corresponding to nodes into the current
output (Figure 3.15-1). Set node channel in the software and perform current initialization.
Pin definition of aviation connector: 1, -signal (black); 2, null; 3, +signal (orange).
Figure 3.17-1
Table 3.17-1 Connection of the current output and node
Varco client output 0-20Ma SK-9N21 analog node
Rotation 2.1-Positive pole 3-4-20mA input
speed 2.2-Negative pole 1-common end
QW260
Torque 3.1-Positive pole 3-4-20mA input
QW262 3.2-Negative pole 1-common end
If the interface given by Varco top drive client output is 0-10V, it will have some troubles
during processing. As the sampling voltage inside the node is 0-0.5V, and the sampling resistance
is 25, so voltage division is needed. Set an equivalent resistance of 470 outside to make the
sampling resistance inside the node within the range of 0-0.5V and also make the current in the
loop within 0-20mA. A-type node of 4-20mA (pins 3 and 1 of node) can be connected to its
voltage output.
Table 3.17-2 Wiring Table
Varco client output 0-10V 470 SK-9N03 analog node
resistance
Rotation 0.1-Positive pole 1 3-4-20mA input
speed 0.2-Negative pole 2 1-common end
QW256
Torque 1.1-Positive pole 1 3-4-20mA input
110
Hardware Manual of CMS Mud Logging Unit
Divider resistance can be disassembled from the standby circuit board. If there is no 470
resistance, resistance of a little larger than 470 will be Ok. But it should not be too large to avoid
affecting the precision. It is suggested that the resistance is 1/2W, and at least 1/4W. The original
drawing for wiring is as follows.
111
Hardware Manual of CMS Mud Logging Unit
several SK-9N11 single-channel CAN bus explosion-proof acquisition interfaces. Connect the
sensors in the three areas to the corresponding interface box channels respectively. Connect the
three-wire analog sensors (such as H 2S and electrical torque) to the corresponding SK-9N11
single-channel CAN bus explosion-proof acquisition interfaces and fasten them.
Use CAN bus shielding cable to connect each SK-9N21 multi-channel CAN bus explosion-
proof acquisition interface box and SK-9N11 single-channel CAN bus explosion acquisition
interface in series. The bus can enter the inside of the explosion-proof shell through different
explosion-proof acquisition interfaces or inlet and outlet of CAN bus shielding cable at the bottom
of the interface box and can be connected to the corresponding connection terminals on the circuit
board. Each explosion-proof interface and interface box are on the bus regardless of the order
(Figure 4-1 and 4-2). The head end of CAN bus is connected to the explosion-proof junction box
in the rear cabin of the mud logging unit, and the last CAN bus explosion-proof acquisition
interface only connects the inlet CAN bus shielding cable. The spare bus connection terminal is
connected to the terminal resistor (Figure 4-3). Then install the engine degasser.
The exposed shield lines at the inlet and outlet of CAN bus cable are connected with each
other
Figure 4.1 Schematic diagram of cable wiring of CAN bus inside SK-9N21 multi-
channel CAN bus explosion-proof acquisition interface box
112
Hardware Manual of CMS Mud Logging Unit
Figure 4.2 Schematic diagram of cable wiring of CAN bus inside SK-9N11 single-
channel CAN bus explosion-proof acquisition interface
Figure 4.3 Connection method for the last interface or interface box
113
Hardware Manual of CMS Mud Logging Unit
Figure 4.4 Field connection diagram of CAN bus equipment adopting SK-9N21/11
explosion-proof acquisition interface box
114
Hardware Manual of CMS Mud Logging Unit
XXI Degasser
XXI.1 SK-7T05 engine degasser
Overview
The redesigned SK-7T05 engine degasser is a new generation of product. This degasser, with
measure of freezing protection, is composed of installation standpipe, fixed seat, screw rod
hoisting gear, gas cylinder and gas purification box (Figure 5.1-1).
115
Hardware Manual of CMS Mud Logging Unit
The hoisting gears of both motor and gas cylinder adopt screw rod structure and hand
wheel adjustment, and they can be adjusted upwards and downwards easily during use.
Optimize the flow direction of gas in the gas cylinder and lower the air inlet of gas
cylinder, thus making the escaped gas due to agitation much easier to be carried to the
air entry by the supplemented air. It has been proved by experiments that this can
enhance the degassing efficiency of degasser (Figure 5.1-2).
Improve the structure of explosion proof motor, thus isolating mud steam from the
motor effectively, preventing oil starvation of lower bearings and insulation of motor
from being destroyed, and ensuring that it can work for long time reliably in the rain in
open air and the steam on the mud ditch surface.
Improve the form of mud outlet pipe of degasser, thus reducing the probability of
escaped gas leaking from the mud outlet pipe.
The gas purification box adopts open structure and is fixed on the upper part of the
standpipe, making the device integrated and convenient for maintenance. Even multiple
kinds of countermeasures have been deployed for the gas cylinder to avoid sucking in
mud; a bridge breaker is still equipped in the box to prevent mud from being sucked into
the gas line. Besides the bridge breaker, there is a drying bottle capable of containing
more desiccants as well, and at the same time, there is a back flash ditch for deliquescent
desiccant (calcium chloride).
Add a leakage detection
valve, making leakage
detection of degasser much
easier.
Inherit and enhance lots of
advantages of the past several
engine degassers of different
types:
With flexible structure,
different components can be
disintegrated conveniently
during installation and
maintenance.
Convenient for adjusting,
when it is required to adjust
the depth of degasser
2a. Install 10 adhesion proof pipe 2b. Install 6all rubber hose
(Install additional 10 banded pipe of rubber hose directly) (Install
additional 6M8 couplers on both ends)
116 Figure 5.1-3 Connection diagram of gas pipeline of degasser
Hardware Manual of CMS Mud Logging Unit
immersed in the mud pit, the operator can finish this job without carrying any tool.
Add measures of mud splashing to make the degassing efficiency higher than general
engine degasser.
Antifreezing measures:
There are two sizes of couplers for the gas collection opening. The smaller sized coupler can
be used to connect common rubber hose. If there are antifreezing requirements, the larger
sized coupler should be used (Figure 5.1-3);
Larger sized hose should be used for antifreezing to reduce the flow rate of gas passing this
hose and increase the retention time of gas in this hose so that there are more possibilities for
water vapor to be cooled, or to make water vapor completely condensed here;
Adopt pipelines (10) made of special material. When water vapors condense, all condensed
water globules can not adhere to the pipeline and they will descent and return to the gas
cylinder as a result of gravitation;
According to the requirements mentioned above, the outgoing pipeline of gas cylinder should
keep vertically upwards status as much as possible to make water globules slide down
smoothly. The length of pipeline can be configured and adjusted as appropriate;
If there are phenomena of freezing at the nozzle of gas cylinder, you can take local insulation
measures additionally;
The pipelines made of special materials are characterized by not absorbing oil and gas, but it
is lack of elasticity like rubber hose. To ensure the sealing performance of its pipe orifice, the
degasser is equipped with a piece of rubber hose with corresponding size, which is hitched on
the end of the special pipeline to strengthen its elasticity.
Technical indicators
Motor
Type: YBSC71-2-4 explosion-proof three-phase asynchronous motor
Power: 370W
Rotation speed: 1400rpm
Power supply: 380V /50Hz
Volume of gas cylinder: 170270mm
Adjustable range of height: ~300mm (installing position adjustment 850mm)
The total weight of equipment: 27kg
Installation and use
Installation
The agitation shaft and the motor are connected to the end screw thread, and a double-
ear lock washer is installed in the middle part to avoid loosening. The coupling seat and the
gas cylinder are fixed with 4 bolts, forming the gas cylinder component. The coupling seat
117
Hardware Manual of CMS Mud Logging Unit
of gas cylinder is installed on the square standpipe and can move up and down. The
installation screw rod at the top of the motor is connected to the upper support arm. You can
use the hand wheel at the top to adjust the height. When adjusting to the predetermined height,
press the hold-down wrench on the coupling seat, then the gas cylinder can be fixed on the
square installation standpipe firmly. There is another fixed seat installed on the square
installation standpipe and you can fix it with mud ditch, etc. firmly using the C shape clamp
on the fixed seat.
Usually the following installation modes are available according to on-site requirements:
C shape clamp of fixed seat can be fixed on one side of the mud ditch or shaker screen
stand directly (Figure 5.1-4).
When intending to install it on the mud outlet pipe, you can weld a steel plate with
appropriate size on the outlet pipe vertically and then fix the degasser on this steel plate
using the fixed seat.
When necessary, you can weld additional fabricated sections (angle steel or flat iron) on
any position where you prepare to install degassers in the same way, and then you can
fix degassers conveniently and rapidly.
The installation direction of degasser should be determined according to on-site
requirements. You can unscrew four unloosing screws that connect the coupling seat and
the gas cylinder and screws on cylinder bottom pup joint, rotate the gas cylinder and the
cylinder bottom pup joint for 90 or 180 respectively and then screw up. Then the
direction of mud inlet and outlet can be changed (Figure 5.1-5)
118
Hardware Manual of CMS Mud Logging Unit
119
Hardware Manual of CMS Mud Logging Unit
Connect the gas pipeline from gas cylinder to the inlet of the bridge breaker inside the
gas purification box, and connect the outlet of the bridge breaker to the inlet of the
drying cylinder using the same gas pipeline. The anhydrous calcium chloride should be
added as the drying agent in the drying cylinder, and the outlet of the drying cylinder is
connected to a small segment of PU pipe in which the non-absorption pipeline is
inserted (Figure 5.1-6).
Bridge
breaker
Figure 5.1-6 Connection diagram of bridge breaker and drying cylinder on the degasser (Take
the connection of 6 all rubber hose as an example)
120
Hardware Manual of CMS Mud Logging Unit
Figure 5.1-7 Connection diagram of bridge breaker and drying cylinder in the gas
purification box (Take the connection of 6 all rubber hose as an example)
Attention:
Anhydrous calcium chloride and other drying agents without absorbability to
hydrocarbon components should be added in the sample gas drying cylinder and should
be replaced as soon as possible after deteriorating caused by damp.
After 4 non-adsorption pipeline and 60C constant temperature heater band are
packed together using insulation cotton cover, they are connected to sample gas inlet of
the rear cabin of the mud logging unit (Figure 5.1-8).
Figure 5.1-8 Packing method of non-adsorption pipeline and constant temperature heater
band
121
Hardware Manual of CMS Mud Logging Unit
Figure 5.1-9 The other end of the non-adsorption pipeline is connected to the sample gas
inlet of the rear cabin of the mud logging unit
After 4 non-adsorption pipeline and 60C constant temperature heater band are
packed together using insulation cotton cover, they are connected to sample gas inlet of the
rear cabin of the mud logging unit.
Figure 5.1-6 Sketch map of connection of heater band and degasser hole seat
Use and operation
When it is required to adjust the height of degasser in the course of operation, first unfasten
the compacting spanner on the connection seat, rotate the hand wheel to adjust the height of
degasser and fasten the compacting spanner after adjusting it to the designated position. Its
adjustable range is 0-300mm. If it cannot be adjusted to the designated position, you can change
the height of fixed mount to adjust the position of the whole equipment and its adjustable range is
850mm.
Two kinds of gas pipes of degasser are available: 10 anti-freezing pipe and 6 all rubber
hose. 10 anti-freezing pipe can be connected directly to the outlet pipe nipple of gas cylinder and
air inlet pipe of bridge breaker of purification box to prevent deformation and loosening in the
course of operation and outside the 10 pipe, a segment of 10 rubber hose (about 30mm long) is
installed to improve its elasticity. When it is required to install a 6 pipeline, add 6M81 joints
at mouths of the inlet and outlet pipes of bridge breaker and gas cylinder (M81 female threads
are available in the inlet and outlet pipes), connect 6 all rubber hose directly to 6 joint.
After using for a period, immediate correction is needed when the packing force of
compacting spanner on the support connection seat is inadequate. (Figure 5.1-7)
Loosen check bolts (M8 hexagonal-head bolt);
122
Hardware Manual of CMS Mud Logging Unit
123
Hardware Manual of CMS Mud Logging Unit
Maintenance
124
Hardware Manual of CMS Mud Logging Unit
In addition, users must inspect the insulation resistance of the motor regularly to judge if
it is invaded by water vapor.
After the gas pipeline is connected or in normal operation, it is necessary to use the
sample air extracting pump equipped for the chromatograph to conduct system leakage
checking. All the rubber end plugs equipped for the purification system of this device are
conical. And the sealing performance can be ensured by stuffing them up with force.
The depth of gas cylinder immersed in the mud should be 40-60mm, in which case the
maximum degassing efficiency can be reached. The operation mode of centrifugal pump
will be generated if it is too deep, while splashing volume of mud will be not enough if it
is too shallow. Anyway, the purpose is to pursue the maximum degassing efficiency.
Users can adjust it according to the displayed base value. After adjusting the height, it is
required to pull the compacting spanner to the limiting position in the fastening direction
to lock it.
If the sand outside the degasser influences mud level and the volume of mud drained out
by the discharge outlet, the degassing efficiency will be changed. It is required to adjust
the degasser or eliminate the sand.
Flush and wipe the dry and wet mud deposited on the degasser regularly.
Check whether dry mud is accumulated inside the nozzle of gas cylinder, and clean the
dry mud, if any.
Check whether gas leaking point exists in each component of the gas circuit and fasten
the component if any leakage is found.
Check the leakproofness of check valve of bridge breaker. When the ball float in the
cylinder floats up to the position of check valve, leakage of the check valve is not
allowed.
Lubricating grease should be added to the wear-prone positions of degasser such as
moving, adjusting, fastening and screwing parts to make it rotate flexibly and avoid
corrosion.
If you find the hoisting hand wheel too tight, you can add lubricating oil to the screw rod.
Method: hoist the degasser to the top, disassemble the support pin of the degasser, take
down the spacing screw at the end of the screw rod, (it should be noticed that the screw is
tightened anticlockwise and unfastened clockwise.) ) After the supporting rod is taken
down, grease can be added to the screw thread. See Figure 5.1-8.
125
Hardware Manual of CMS Mud Logging Unit
126
Hardware Manual of CMS Mud Logging Unit
balance according to deficiencies of the existing device, requirements of on-site use and
features of environment.
The full stainless steel is adopted, which has greatly improved the resistance of equipment
parts to environment corrosion and reliability of work, and extended the service life of the
equipment.
Automatic heaving pontoon is designed to replace hand winch based on buoyancy
principle of the mud. Adjust the balance weight of steel cable according to the density of
on-site mud to realize rapid height positioning and balance locking of the degasser in the
mud ditch, which makes the height adjusting of the engine degasser in the mud ditch very
convenient and saves time and force.
Inherit and enhance lots of advantages of SK-7T02G engine degassers:
Add measures of mud splashing to improve the degassing efficiency of the degasser.
For the gas cylinder, under the premise of keeping high degassing efficiency, the control
on the mud splashing position should be strengthened to prevent the mud from polluting
and blocking the outlet of the gas circuit.
Based on connection structure of the explosion-proof motor, it improves the motor with
regard to isolating mud steam and prevents oil starvation of lower bearings and
insulation of motor from being destroyed. Special processing can ensure the explosion-
proof motor work for long time reliably in the rain in open air and the steam on the mud
ditch surface.
The gas purification box of open structure, integrated with the device, is convenient for
maintenance.
With simple and flexible structure, it is easy to disassemble and convenient for
installation and maintenance.
Compared with SK-7T02G engine degasser, it has some prominent advantages as follows:
It adopts the automatic buoyancy principle and realizes unmanned height adjusting of the
degasser under the premise of keeping the maximum degassing efficiency, remarkably
reducing the labor intensity of operators.
With full stainless steel material and simple and practical structure, the reliability and
service life of the equipment are improved.
With Simple installation and convenient operation, it is more suitable for field drilling.
Technical indicators
Motor
Type: YBSC71-2-4 explosion-proof three-phase asynchronous motor
Power: 370W
Rotation speed: 1400rpm
Power supply: 380V/50Hz
127
Hardware Manual of CMS Mud Logging Unit
128
Hardware Manual of CMS Mud Logging Unit
rotate the erecting poles to align the threaded holes on the erecting poles with the
round holes on the cylindrical sleeves of the carrier and fix them with M816
screws. (Note: There are threaded holes on both ends of the erecting poles; don't
install it reversely.)
C. Align two U Shape slide ways on the pontoon of the gas cylinder component with
the internal side of those two erecting poles, let the gas cylinder components slide
down erecting poles slowly and put them on the carrier slightly at last.
D. Put two cylindrical sleeves on the beam onto the upper ends of those two erecting
poles respectively and fix them with M816 screws.
E. Hook the spring hook on one end of the steel cable component onto the joint hinge
of the explosion proof motor of the gas cylinder component and thread the other
end through two pulleys and droop.
F. Align two mounting holes on the bottom of gas purifier with those on the right side
of the beam and fix them with M825 screws firmly.
G. Installation of rubber hose
a) There are two sizes of rubber hose couplers equipped for the gas connection
opening. The smaller sized coupler can be used to connect common rubber hose. If
there are antifreezing requirements, the larger sized coupler should be used to
reduce the flow rate and increase the retention time of gas so that water vapor can
condense completely. See Figure 5.2-2-a and 5.2-2-b.
b) During installation, the outgoing pipeline of gas cylinder should keep vertically
upwards status as much as possible to permit water globules formed due to
condensation to slide down smoothly.
c) The length of pipeline can be configured and adjusted as appropriate.
d) If phenomena of freezing appear at the air outlet of gas cylinder, you can take local
insulation measures.
129
Hardware Manual of CMS Mud Logging Unit
Fig.a Install large rubber hose Fig.b Install small rubber hose
Figure 5.2-2
130
Hardware Manual of CMS Mud Logging Unit
Figure 5.2-3 Schematic diagram of field installation of SK-7T03 pontoon engine degasser
Field installation
After assembling engine degasser properly according to the above steps, erect and weld the
additional fabricated sections (two 5# angle steels with equal legs) equipped for the device on the
top of the mud ditch as per field positions, and then erect the degasser on the angle steels. Then
you can place the degasser at the working position conveniently and finish the field installation
(Figure 5.2-3).
Power supply connection (Figure 5.2-4)
Hole seat of heater band (see from wiring direction) Hole seat of degasser (see from wiring
direction)
131
Hardware Manual of CMS Mud Logging Unit
Figure 5.2-4 Sketch map of connection of heater band and degasser hole seat
Use and operation
Preparation before using
1) Before using, it is required to check whether the air discharge outlet of gas cylinder is
smooth or not and to clean out mud or other sundries.
2) Before using, it is required to check the leakproofness of components in the gas circuit
and fasten them.
3) Check the leakproofness of check valve of
bridge breaker. When the ball float in the
cylinder floats up to the position of check
valve, leakage of the check valve is not
allowed.
Main operations
Installation of rubber hose
For the gas pipe of degasser, large-
size anti-freezing rubber hose and small-
size rubber hose are available and the
large rubber hose can be connected
directly to the outlet joint of gas cylinder
and air inlet pipe of bridge breaker of gas
purification box.
Fig. 5.2-5 Schematic diagram of optimal
When it is required to install small-size mud discharge
rubber hose, it is feasible to add special joints
to the outlet joint of gas cylinder and air inlet pipe of bridge breaker of gas purification
box and then install small rubber hose on the joint.
Selection of balance weight
To ensure the maximum degassing efficiency of the degasser, the following is
suggested, the depth of gas cylinder immersed in the mud meets the requirement that at
the operating status, the mud amount discharged from the gas cylinder is equivalent to
approximately 1/3 of the pipe diameter of discharge outlet. Users can adjust the balance
weight according to this to confirm the depth of the mud submerging the pontoon. After
the balance weight is selected properly, the mud is splashing through stirring. The
schematic diagram of optimal mud discharge is shown in Figure 5.2-5.
Removal of balance weight
When removing the balance weight, it is required to slowly lower the steel cable to
prevent the degasser from sliding down quickly and hitting the floating pipe and to
132
Hardware Manual of CMS Mud Logging Unit
133
Hardware Manual of CMS Mud Logging Unit
logging unit or the wellsite compressed air, so as to prevent the mud logging unit from water
accumulation and blockage after long time operation. It is the active cleaning device necessary for
each mud logging unit (Figure 5.3-1).
Features:
Two blowback gas sources available:
Air compressor installed in the instrument room
Air compressor outside the wellsite.
Blowback with the air compressor in the instrument room is the default setting.
It is convenient and easy to operate.
The filter can effectively prevent mud from being sucked into the chromatograph.
Filter
Automatic drain
port
Filtered
To be
filtere
outlet
e gas
Sampl
e gas
outlet
Sampl
room Air
inlet
d
in the
compr
instru
essor
ment
Air
134
Hardware Manual of CMS Mud Logging Unit
Figure 5.3-2 Gas circuit wiring diagram of sample gas blowback device
The flow of gas circuit:
The normal flow of gas circuit
Air 1: Wellsite compressed air interfacefiltering pressure-reducing valve To be filtered pipe
jointactive carbon pipesilicagel pipeconnect with the Filtered pipe jointquick
four-way valve Air outlet pipe jointactive carbon pipesilicagel pipe
scram valveblockage
PE (bridge breaker)quick four-way union; The other three connections of the quick
four-way union will be connected to such units as 9G01 and 3Q04, etc. after connecting
with gas pipes.
Air 2: Pipe joint at Air compressor in the instrument roomquick four-way valvepipe joint at
Air outletactive carbon pipe
scram valveblockage
silicagel pipePE (bridge breaker)quick four-way union; The other three connections
of the quick four-way union will be connected to such units as 9G01 and 3Q04, etc. after
135
Hardware Manual of CMS Mud Logging Unit
Attention:
Either wellsite compressed air or air from air compressor in the instrument room can be
used.
Use
You can press the blowback button on the scram valve to clean pipeline through blowback
when vapor invades into the sample gas circuit or even mud is sucked into pipeline or the pressure
of vacuum gauge on cabinet panel is negative.
Sometimes, various additives will be added into drilling fluid due to engineering
requirements during drilling. After using some of the lipid additives with low fluorescent light for
a period, the gas pipeline will be contaminated seriously, especially, TG value is high for a long
time. In this condition, the blowback unit should be used to clean pipeline thoroughly during
tripping and the effect will be remarkable.
It's worth notice that one end of gas pipeline outside the instrument room should be
disconnected from drying cylinder, bridge breaker or sand-core filtering ball which are connected
to degasser to keep the gas pipeline smooth completely before performing blowback.
The time for blowback depends on the practical condition. If there is only vapor, maybe two
or three minutes will be enough; if the pipeline is dirty or contaminated by heavy hydrocarbon, the
time will be longer and maybe you should do it for more than one time. Once the blowback
operation is finished, a few minutes will be needed for the air compressor to restore pressure, so
136
Hardware Manual of CMS Mud Logging Unit
you can press the blowback button to continue blowback after the pressure of air compressor is
increased. The pipeline will be cleaned thoroughly by repeating this operation as mentioned above
for several times.
Maintenance:
After the system is aerated, it is required to check whether leakage occurs in every valve,
pipe joint and gas pipe regularly (apply neutral detergent on joints and valves for test using pen
brush or paintbrush). If leakage occurs, the system should be readjusted. You can wrap the
connection again with pipe thread seal tape and screw it or replace the damaged or failed elements.
The drying agent of silicagel is contained in the gas circuit of this unit. When the compressed
air from outdoor wellsite is adopted, the active carbon should be used as filtering medium to
provide clean gas source for chromatograph and other units. But it is forbidden to use silicagel as
the drying agent in the drying cylinder of sample gas circuit due to the adsorption of silicagel
which will affect the gas survey data!
137
Hardware Manual of CMS Mud Logging Unit
Explosion-proof classification:
Base
Explosion-proof symbol: Exd II Guard
plate
shield
CT6 H2 /DIP A21 TA T6; Protection
class: IP65
Model
ZA T 600
Figure 6.1-1 External structure diagram
Product No.
Classification symbol
Company logo
External structure
External dimensions (LWH): 320mm300mm340mm.
Weight: 16Kg.
External structure diagram: As shown in Figure 6.1-1.
Safety notices
Definitions of Danger and Attention:
Danger: Operating not in compliance with the requirements will give rise to serious
equipment damage or physical injury.
Attention: Operating not in compliance with the requirements will give rise to moderate or
slight physical injury or property loss.
Installation
There should be professionals responsible for field installation.
Fix the base plate firmly.
Connect it to ground reliably.
Wiring
Danger
Professionals are required for the wiring operation. Otherwise, electric shock is
likely to occur.
Before wiring, the input power source should be disconnected completely.
Otherwise, electric shock is likely to occur.
The grounding terminals of the integrated machine should be connected to
138
Hardware Manual of CMS Mud Logging Unit
Attention:
Dont connect the power input wire with video or communication wire
reversely; otherwise property damage is likely to occur.
Blue: AC220V
Yellow: 485+
Video: +
White: 485-
Video:
Brown: AC220V
(b) Debugging
Dial code switch setting
Dial code switch SW1: 1-8 digits; Address: binary setup method; the dial codes for Address 1
to 65 are shown in Table 6.1-1 and the maximum number of Address is 255. (For other data, refers
to Attached Table 1)
Table 6.1-1: 1 represents ON and 0 represents OFF
Switch Switch Switch Switch Switch
position Address position Address position Address position Address position Address
12345678 12345678 12345678 12345678 12345678
10000000 1 01110000 14 11011000 27 00010100 40 10101100 53
01000000 2 11110000 15 00111000 28 10010100 41 01101100 54
11000000 3 00001000 16 10111000 29 01010100 42 11101100 55
00100000 4 10001000 17 01111000 30 11010100 43 00011100 56
10100000 5 01001000 18 11111000 31 00110100 44 10011100 57
01100000 6 11001000 19 00000100 32 10110100 45 01011100 58
11100000 7 00101000 20 10000100 33 01110100 46 11011100 59
00010000 8 10101000 21 01000100 34 11110100 47 00111100 60
10010000 9 01101000 22 11000100 35 00001100 48 10111100 61
01010000 10 11101000 23 00100100 36 10001100 49 01111100 62
11010000 11 00011000 24 10100100 37 01001100 50 11111100 63
139
Hardware Manual of CMS Mud Logging Unit
As shown in Table 6.1-3, the 11-12 digits of the dial code switch SW1 are the corresponding baud
rate setting of the video camera.
Table 6.1-3
Dial code switch Baud rate
position bps
11 12
0 0 2400
1 0 4800
0 1 9600
1 1 9600
Communication protocol
PELCO-D, PELCO-P or customized protocol. (The protocol is auto-adapted and not related to
the dial code switch).
140
Hardware Manual of CMS Mud Logging Unit
instrument.
The lens control board will be unavailable when the RS485 interface is contained in video
camera. You only need to connect the 12V power wire to the RS485 communication
and video wires while wiring for video camera. The address of video camera is 2.
Baud rate can be set according to the 11-12 digits of dial code switch. The video
camera protocol is PELCO-D. (Depending on model of the video camera, the protocol
can be modified as required)
Figure 6.1-3
Wiring description:
The ports of 12V and GND should be connected to the power wire of video camera;
The ports of Focus, Zoom and Com should be connected to the focusing, zooming
and common port of video camera respectively.
Insert coaxial cable with BNC joint directly into the corresponding video output of
video camera.
Attention:
If there are some wires disassembled during wiring, you should connect them according to
the original status according to the color as shown in figure above.
Instruction for external wiring of power, control and video wires:
Unscrew the bottom cover of the base plate of video camera using tools to expose the
terminal block as shown in Figure 6.1-4:
141
Hardware Manual of CMS Mud Logging Unit
1
5
ON
2 OFF 1 2 3 4 5 6 7 8 9 10 11 12
3 6
7
Figure 6.1-4
It is the dial code switch. For the specific dial method, refer to the section of dial code
switch setting.
Jumper terminal of terminal resistance (RS485 signal, 120 ohm).
Connection terminals of the integrated cable.
V0+: Connect to coaxial cable core.
V0-: Connect to shielding layer of the coaxial cable.
A: Connect to 485+.
B: Connect to 485-.
L, N: Power inlet terminal. Connect to AC220V.
2A/250V fuse.
Signal indicator.
Power indicator.
Connect to the timing board.
Connect to the control board.
Connect to the lens control board and wiper control board.
142
Hardware Manual of CMS Mud Logging Unit
143
Hardware Manual of CMS Mud Logging Unit
144
Hardware Manual of CMS Mud Logging Unit
transportation and in open storage during transshipment on route. They should not be
loaded and transported together with the flammable, explosive and corrosive products
during transportation. It is forbidden to expose the product components to rain, snow or
liquid and the mechanical damage is also prohibited.
It is required to carry them gently and tumbling and inverting is strongly forbidden
during transportation.
The time of transshipment should be as few as possible. Products should be
loaded/unloaded in good condition. Mechanical operation should be adopted for the
main transportation and handling to prevent brutal handling.
Storage
Valid period is half a year since packaging. During this period, the storage storing
products should be of good ventilation and the concentration of acid, alkaline and other
harmful gas in air should meet the requirement of environmental policy.
All packaging boxes should be moisture resistant, i.e., the stands supporting packaging
boxes should be placed at least 30cm above ground and 40cm from wall.
The packaging boxes should be placed strictly according to the storage and
transportation diagram on box and the placing layers should not exceed the limit layer
of each box.
The packaged product should be brought to use immediately after acceptance or the
time for storage and transportation should not exceed half a year. After reaching the
destination, the box should be opened within 3 months.
(g) Check and Maintenance
Summary of regular inspection
Ta r g e t Inspection
Item inspected Standard
inspected method
1. Inspect the temperature, 1. Visual 1. Comply with
humidity, vibration and water inspection or the technical
drop of the ambient environment. use instrument. specification.
Ambient environment
2. No foreign matter and 2. Visual 2. No related
dangerous articles such as tools inspection. articles are
are placed around. placed.
Whether the voltage of main Visual Comply with
Voltage circuit and control circuit is inspection or the technical
normal? use instrument. specification.
Bracket and sun shade, 1. Is there any abnormal sound 1. Visual There is no
etc. and vibration? inspection and abnormal
2. Whether the screws and other listening. situation for the
fasteners are loosened? 2. Screw up. three items.
3. Is there any deformation? 3. Visual
145
Hardware Manual of CMS Mud Logging Unit
inspection.
1. Is there any peculiar smell and 1. Screw up There is no
insulator cracking due to 2. Visual abnormal
For public use overheating? inspection. situation for the
2. Is there any disconnection? two items.
146
Hardware Manual of CMS Mud Logging Unit
Guard
shield
Angle adjust knob of guard
shield
Stand type
installation carrier
147
Hardware Manual of CMS Mud Logging Unit
Unlike domestic products of similar type, this explosion-proof display adopts restricted
breathing structure design. Compared with the common isolated type explosion-proof display, this
display features small size and light weight. It is convenient to operate with the novel front door
opening structure and various types of installation carriers are available such as stand and bench
type. It will be equipped and installed by our company according to the specific requirements of
users.
Technical indicators
Ambient temperature: -20 ~ 50
Storage temperature: -30 ~ 60
Relative humidity: <90%
Structure characteristics: All stainless
steel structure and resistance to dust, rain,
corrosion and explosion.
Protection class: IP65
External dimensions: 462391185mm
Display area: 336264mm
Weight: 23Kg (not including installation carrier)
Screen: 17 TFT
Point interval: 0.297mm
Maximum resolution: 12801024
Scanning frequency: Horizontal: 30~70KHz; Vertical: 56~85Hz
Color: 256K
Luminance: 400cd/m2
Contrast: 500:1
Horizontal visual angle: 70/70
Vertical visual angle: 50/70
Signal input: Analog type: R.G.B/VIDEO
Signal interface: 15-hole D-type socket /video plug
Explosion-proof structure: Restricted breathing explosion-proof structure,
compliant with the national standard of
GB/3836.8-200
SK-4X03 multi-function display which adopts the restricted breathing explosion-proof
structure can meet various explosion-proof requirements of Zone 2 dangerous places.
Restricted breathing explosion-proof system
The shell of SK-4X03 multi-function display is designed according to the requirements
of restricted breathing shell. Gas tightness requirements: 80s after the positive pressure gas of
300Pa flowing into shell, the remaining gas pressure in cabinet should be not less than 150Pa.
148
Hardware Manual of CMS Mud Logging Unit
Generally, the seal structure of shell prevents the flammable gas entering into shell, so as to
meet the explosion-proof requirements. The protection class of the restricted breathing shell
should be not less than IP65 and this shell can be used in Zone 2.
4. Electric wiring
Power connecting wire (from power cable reel to switching power supply)
Three-hole plug of power YZW30.75 cable XS18K3CI XS18J3CI 220V input
switching power
supply
L Brown 2 2 L
N Blue 3 3 N
E Yellow-green 1 1 E
Video signal connecting wire (from video signal cable reel to control board)
DB15 plug of VGA video XS18K14CI XS18J14YC VGA video cable DB15 plug Remarks
(green)
2 Blue 5 5 Blue 3 Blue
(blue)
5 White 7 7 White 5 GND
shield
12 Brown 8 8 Brown 12 GND
13 Black 9 9 Black 13 HS
14 Yellow 10 10 Yellow 14 VS
149
Hardware Manual of CMS Mud Logging Unit
Attention:
For the video cable of different specifications, the number of cable cores and the color may be
different, so the method of pin connection shall prevail for connecting.
The colors in the above table are only used for reference.
If there is no specific instruction on the length of connecting cable, the actual cable length shall
prevail.
When connecting, you should pass the video cable through the cabinet of the multi-function
display first and tie it in the cabinet to prevent loosening, and then put on the EMI toroidal
magnetic core.
150
Hardware Manual of CMS Mud Logging Unit
Heat conduction
silicagel should be
set on inversion
plate
LCD
screen
Fan
assembly. It
is the fan
with 12V
power LVDS wire
supply.
151
Hardware Manual of CMS Mud Logging Unit
There are totally 6 groups of interfaces in the remote telephone junction box, with each two
adjacent lines as a group beginning from the left end. Connect according to the default setting. The
corresponding phone numbers of the 6 groups of interfaces should be 201, 202, 203, 204, 205 and 206
respectively from left to right and the default number of the programmable telephone in logging unit is
200. If you forget the number of one remote telephone after connection, you can dial the programmable
telephone (the number is 200) in logging unit using this telephone, then the number of this remote
152
Hardware Manual of CMS Mud Logging Unit
155
Hardware Manual of CMS Mud Logging Unit
Close the switch valve after generating hydrogen for 3 minutes, namely set the switch
valve to Off position (clockwise), then observe the displayed value of Hydrogen
pressure on the liquid crystal screen and the pressure of hydrogen gas shall rise to 0.4MPa
within 5 minutes and at the same time, the displayed value of Hydrogen yield decreases
to 0, indicating the generator runs normally and here it can be connected to the
equipment using hydrogen gas. The hydrogen delivery outlet adopts f 3 stainless-steel
tube, seal ring of f 3 hole and screw nut and it is connected to the equipment using
hydrogen gas (spare parts);
After connecting, first flush the pipeline, close the switch valve after the generator
generating hydrogen gas for 3 minutes to make its pressure rise to 0.4MPa and open the
switch valve to blow off hydrogen gas in the pipeline. Repeat the pressure rise and
hydrogen blow-off operations for 2-3 times. Until what in the system is basically hydrogen
gas.
This generator carries out automatically constant pressure (0.4MP) and constant current of
hydrogen gas. The electrolyzer produces hydrogen changing with hydrogen consumption
and the electrolyzer runs continuously, supplying gas as it is produced. The indicating
value of hydrogen production meter is the value of hydrogen consumption.
Shutdown operation
When stopping using the hydrogen gas, first close the switch valve and then cut off the
power supply, keeping the hydrogen status;
When using the hydrogen gas, first switch in the power switch and then open the switch
valve to produce and supply hydrogen gas.
Maintenance
The generator produces hydrogen gas using the method of water electrolysis and it should be
noticed to add the water used for electrolysis as the water is used and consumed and when the
water drops below the lower limit of liquid level, it is required to add the distilled water (or
deionized water, ultra-filtered pure water) to the fluid storage container. For the operating
method, see startup preparation: filling-up electrolytic solution. If the water used for
electrolysis is not added, the alarm of low water level will be given (it is still producing and
supplying hydrogen gas at this moment, the Water level indication on the liquid crystal
screen switches from Normal to Over-low and is flashing). The generator will self-protect
and stop producing hydrogen due to shortage of water if the water used for electrolysis is not
added any more after ten minutes. It should be operated as follows:
Cut off the power supply;
Add the distilled water;
Switch in the power supply, the Water level indication on the liquid crystal screen is
Normal, continue to produce hydrogen.
If the color of electrolytic solution changes, it is roily and the hydrogen yield decreases after it
is used for a while, it is required to replace with new electrolytic solution (it is recommended to
replace the electrolytic solution once every three months).
The allochroic silicagel in the drying cylinder changes from light blue to light pink, showing it
has been damp due to absorbing water and replacement is required when the color of 2/3
allochroic silicagel changes. Replacement operation:
Cut off the power supply, bleed off the hydrogen gas, unscrew the drying cylinder
anticlockwise and then lift upwards and take it out.
Anticlockwise unscrew the light gray plastic sealing cover in the upper. Take out the cotton
and put out the damp silica gel.
Put in the dry silica gel, put in the cotton and screw up the sealing cover (screw up as much
156
Hardware Manual of CMS Mud Logging Unit
as possible).
Restore the drying cylinder, screw in the sealing socket. Dont screw in too tight and it is
ok if no gas leaks.
Desorption treatment of silica gel: the damp silica gel is put in the electric heating oven and the
temperature is controlled at about 120.Take it out when the color of silica gel
becomes blue, cool it down to normal temperature and put it in the bottle for use.
Ensure the generator works normally and the air tightness of the whole gas circuit is vital. Due
to limited hydrogen production, gas leakage will give rise to increase in the addition load,
which will cause damage to generator. Please pay attention to air tightness in the operations of
connecting gas pipes and replacing silica gel and so on.
Notice
The generator produces hydrogen gas using the method of water electrolysis and it should be
noticed to add the water used for electrolysis as the water is used and consumed and when the
water drops below the lower limit of liquid level, it is required to add the distilled water.
The electrolytic tank is the heart of generator and users are not allowed to disassemble it to
prevent the electrolytic tank from unrecoverable damage. Please contact the production plant if
problems are found. The user should be responsible for the damage caused by self-dismounting
(even in warranty period).
The electrolytic solution in the fluid storage container should be emptied first before
transporting the generator to avoid the external overflow of electrolytic solution to damage the
generator. The electrolytic solution in the fluid storage container is emptied by using the ear
syringe ball (accessory).
The water storage barrel is positive potential and it cannot be interconnected to other
components.
In order to ensure the generator runs safely, users cannot adjust the pressure at random to avoid
abnormal operation.
157
Hardware Manual of CMS Mud Logging Unit
Motor
Power switch
Portable position
Portable position
158
Hardware Manual of CMS Mud Logging Unit
Air filter
be obtained using the thermovacuum distilling degasser. When the gas-oil ratio is low, the drilling speed
is low and the mud is dense with large specific gravity, the floater or engine degasser is used and the
extremely small amount of gas degassed may leak to the oil and gas layers. However, a better effect will
be obtained using the thermovacuum distilling degasser. In combination with analysis of
chromatographic analyzer, it will provide reliable basis for qualitative and quantitative interpretation of
oil and gas layers. Gas contained in the mud exists in the forms of liberation, dissolution and absorption.
Methods of heating, mixing and pressure relief are used to make the gas in the mud expand and
volatilize in great deal and almost all gas is separated.
Features
Compared with SK-7R01 or other products of similar type, SK-7R02 thermovacuum full degasser
has the following features.
Compact structure and beautiful appearance;
The volume of mud bottle is 250 ml and the mud for analysis is also determined as 250 ml;
For the mud for analysis, the fresh mud is filled in the mud bottle at the outlet trough and then
the sealed cover is placed immediately;
Replace the round bottom flask with stainless-steel mud bottle, thoroughly eliminating the
hidden danger from explosion of glass bottle and improving the safety.
Technical indicators
Degree of vacuum of system: 1.3KPa;
Pumping speed: 1ml/s;
Leakproofness of system: after the degree of vacuum reaches 1.3KPa, cut off the atmos valve
for 2h and the vacuum gauge will drop not more than 0.26KPa by visual inspection.
Heating power: 300W;
Volume of mud bottle: 250ml.
Installation
SK-7R02 thermovacuum distilling degasser consists of gas cylinder, main body for degassing, mud
bottle, heating stirrer, vacuum pump, oil bottle and saline bottle filled with saturated saline water and so
on. Users can assemble the instruments according to graphic presentation (Figure 5.1-6).
Gas cylinder: consist of vapor metering cylinder and glass bottle with round bottom. Used for
metering and storing the gas separated from the mud.
Main body for degassing: consist of vacuum gauge, observation window and three valves.
Realize and control the gas degassing.
Stirrer: used for heating and stirring the mud to improve the degassing efficiency.
Mud bottle: used to store and heat mud. The volume is 250ml.
160
Hardware Manual of CMS Mud Logging Unit
Attention:
If the degassing requirement is not high, users can replace saturated saline water with fresh water.
161
Hardware Manual of CMS Mud Logging Unit
Ready to vacuumize. Anticlockwise rotate the conical head to make the pricking pin not
exposing the end of conical head; then apply silicone grease on the conical head (improving
the seal between the conical head and mud bottle), place the mud bottle in the conical head
and slight support upwards by hand (Please note to compact upwards to make the mud bottle
not to drop and the purpose of this step is to keep the mud bottle and conical head in sealing
status).
Vacuumize
Start up the vacuum pump to vacuumize to make the pressure gauge stabilize below
-0.09MPa and here the main body and air cylinder are in the vacuum status.
Switch valve A to Off.
Switch valve B to Off, close the pump and pull out the plastic pipe labeled with connection
to vacuum pump (avoid oil reversing out from the oil tank).
Degassing preparation
Slowly switch valve A to Saline water to connect the gas cylinder to saline bottle and quickly
switch valve A to Off after the height of saline water in the round bottom bottle is 2-3cm.
Degassing
Clockwise rotate upwards the conical head to the end to make the conical head pierce mud
sealing cover. Then put the heating stirrer in the tray (the tray is in the lower position), put it
at the bottom of mud bottle, loosen the lock nut in the upper of bracket of main body and
adjust the height to make the bottom of mud bottle close to the heating stirrer, screw up the
lock nut and adjust the height of tray on the heating stirrer through the spanner (handle)
below the tray to make the mud bottle seat on the heating stirrer.
Start up the heating stirrer, rotate stirring and temperature control knobs to certain position,
heat and stir the mud and gas continuously escapes from the mud; when the pressure is up to
-0.07MPa, switch valve A to Gas storage to make the gas cylinder connect to the main
body and mud bottle, continue heating, distill and degas until the pressure of pressure gauge
gradually rises to -0.06MPa and shut down the heater.
Gas collection
Switch valve C to Saline water, interconnect the saline bottle to the main body, the liquid
level in the observation window rises quickly and the saturated saline water squeezes the gas
to gas cylinder; when the liquid level rises near to the top of observation window, quickly
switch valve C to Mud bottle.
Switch valve A to Saline water to interconnect the gas cylinder to the saline bottle, the
saturated saline water squeezes gas to metering cylinder to make the water level in round
bottom bottle and metering cylinder rise, and after the pressure balance, what in the top of
metering cylinder is gas degassed.
Sampling
Extract gas from the top of metering cylinder using an injector and then inject into the
chromatographic analyzer for analysis. If the quantity of gas in the metering cylinder is inadequate for
analysis, a certain quantity of air can be injected and mixed with sample gas to be used for analysis. It
will be converted after analysis.
Washing
Unscrew the top cover of metering cylinder or pierce into the top of metering cylinder using
an injection needle to blow off excessive gas to make the saline water in the gas cylinder
return to the saline bottle.
Switch valve A to Gas collection, switch valve C to Saline water to interconnect the
main body to the saline bottle and discharge the water in the observation window to the
wastewater trough. Unscrew the cover of observation window and wash.
Unscrew the metering cylinder and round bottom bottle and wash them.
162
Hardware Manual of CMS Mud Logging Unit
Remove the heater; take down the mud bottle using special tools and wash it.
Screw up the top cover of metering cylinder, apply a small amount of silicon ester where is
sealed, install the metering cylinder and round bottom bottle, replace the mud bottle,
approximately supplement the saline water to the saline bottle and prepare the next mud
sample.
Table 5.1-2 Table of valve positions (front view of main body)
Valve Valve position Explanation to the status
name
Gas collection (upper) Interconnect the gas cylinder to the main body
Valve A Off (middle) Close passageways of main body, gas cylinder and
saline bottle.
Saline water (lower) Interconnect the gas cylinder to the saline bottle.
Pump (upper) Interconnect the main body to oil tank and vacuum
pump.
Valve B
Off (lower) Close passageways of main body, oil tank and
vacuum pump.
Mud bottle (right) Interconnect the main body to the mud bottle.
Valve C
Saline water (left) Interconnect the main body the saline bottle.
163
Hardware Manual of CMS Mud Logging Unit
iron bar f 20mm or angle steel 30mm).The null line cant be used as a ground line;
The power supply used in this instrument is single phase 220V, 50Hz. The voltage value,
polarity and power, etc. of the power supply network should be checked before moving the
instrument or replacing the plug and socket of power supply. They can be connected into the
instrument only when they are proved to meet the requirements;
Pay attention to the requirement when replacing the fuse of power supply. The specific
specifications can be found in the instruction. Or carefully check the specification of the
replaced fuse, and replace it with fuse of the same specification;
During maintenance, if it is necessary to disassemble the cover panel of the instrument,
attention must be paid to that the plug socket of power supply has been disconnected.
The working procedure of the instrument is fixed. Please dont alter it at will.
Prevent from scalding
There exists heating temperature when the instrument FID and chromatographic column with a
furnace are working, and there is no time for the temperature disseminating when shutdown for
maintenance, so attention should be paid to preventing from scalding accident.
Safe use of gas
When using he hydrogen generator while the instrument is working, evacuate the hydrogen
gas outdoors.
Check the gas circuit of quick chromatograph for any leakage strictly to ensure there is no
leakage.
Hydrogen generator consumes water after producing hydrogen, so deionized water or
distilled water should be added when the water level is lower than the alarm point. The
added water should not exceed the upper limit water line.
The water in the gas cylinder of the air compressor should be discharged frequently, and the
drain valve should be shut off after the water has been discharged.
Normal operation of the system
The pressure, flow and analysis cycle (the retention time of C 1-C5 gas components) have
been adjusted when the instrument leaves factory and it is unnecessary for users to make any
adjustment.
The pre-treatment system such as glass sand-core filtering ball and filter element at the input
end of sample gas should be replaced frequently (for the replacement method, see the
relative contents of the instruction) to ensure the system works normally.
Sample pipeline is usually exposed to pollution from the hydrosphere. Pipeline back-blowing
should be performed if any pollution is identified.
Touch screen setting
164
Hardware Manual of CMS Mud Logging Unit
Be sure to keep the touch screen clean, and dont operate the system with oil stained hands.
To ensure reliable work of the system, please use the operation pen of touch screen to set
operation conditions or communicate externally.
Data uploading
3Q04 chromatograph will stop real-time sampling and real-time data communication when
uploading data files; it only performs data files transmission. 3Q04 will restore to the normal
operation automatically after finishing data files transmission. Dont transmit files under
normal operating condition to prevent from missing logging. The main interface is not
updated in real time in the course of file upload when the status interface can be viewed.
The background software can save chromatographic data in real time, and the storage format
is the same as the uploading format, therefore, data uploading is just used as a means of
backup.
When the program runs normally, the data transmission mode can be selected and
Autoexec.bat under DOS can be modified as C:\3q04\3Q04 parameter (Parameter=0: network
transmission mode; =0: serial port transmission mode; =2: network+serial port transmission
mode)
It is suggested to use network transmission mode under favorable condition to transmit data
(versions after v3.00).
(a) Product overview
SK-3Q04 hydrogen flame chromatograph is used for real-time measurement of natural gas in the
field of petroleum drilling and exploration. Its features are to provide two analysis modes for C 1-C5
components of oil and natural gas with two analysis cycles: 30s and 90s.SK-3Q04 hydrogen-flame
chromatographic analyzer consists of SK-9G01 sample pretreatment unit and SK-3Q04 hydrogen flame
chromatograph. The panel of instrument is concise and gas circuit part of analysis unit includes VMS
injection port, carrier gas pressure gauge and sample gas pressure gauge; the measuring control part
includes liquid crystal screen and power switch only. All the dialogues are carried out through the touch
keyboard/display, the large-screen TFT liquid crystal display is adopted and it can display much
information such as analysis status, control process, FID operation and chromatographic data
processing, qualitative and quantitative process, analysis results and chromatograph charts, etc.
Attention: SK-3Q04 hydrogen flame chromatograph is a fast chromatograph. The output
modes by recording instrument and integraph are reserved and it is recommended to use the mode of
electronic record. Shenkai Company has specially developed the mode of no-paper record and provides
the corresponding software support. Traditional recorder uses the mechanic drive mode, which is easy to
underdo or overdo in the case of rapid signal response, giving rise to relatively large signal distortion.
So please use it with caution.
(b) Operating principle
An instrument manufactured on the principle of gas chromatograph, SK-3Q04 hydrogen flame
chromatograph can obtain on line natural gas samples degassed from the mud degasser, separate them
in the chromatographic column and get qualitative and quantitative data of compounds from the
detector.
Gas chromatograph uses the gas as flowing phase (carrier gas); after being injected through an
injector or imported to the quantitative tube (sample injector) through sample pump, samples are
carried to the chromatographic column by carrier gas. Due to slight difference in solubility factor of
various components of sample in the flowing phase (gas phase) and fixed phase (liquid phase) in the
chromatographic column, various components, flushed by carrier gas, repeatedly dissolve, volatilize
and distribute in the two phases to make them separated in the chromatographic column. Then
components are detected according to their outflow time using detector after the column.
Separating method
165
Hardware Manual of CMS Mud Logging Unit
166
Hardware Manual of CMS Mud Logging Unit
SK-3Q04 adopts the intelligent measurement control system controlled by computer and the
system includes power system, furnace temperature control, analytic system, signal control, total
hydrocarbon and component electrometer, TFT display, touch screen and special chromatographic
workstation, etc.SK-3Q04 system is of fool-model operation; it will automatically enter the control
program after users pressing the switch, automatically ignite the flame of total hydrocarbon and
component FID after the system is stable and automatically analyze the samples from degasser.
The measurement range of SK-3Q04 is wide and thus it is required to use special high-precision
regulating unit. This unit is under the control of SK-3Q04 software and it can display the separation
waveform of components on the panel; inheriting the high-resolution tradition of Shenkai Company, the
measurement range can cover all the waveforms of peaks from the minimum detection limit to full
range. The block diagram of measurement control system is shown in Figure 5.2-3.
168
Hardware Manual of CMS Mud Logging Unit
Power switch
Panel+TFT
Total hydrocarbon FID
169
Hardware Manual of CMS Mud Logging Unit
Product overview
Front and rear panels of SG-9G01 sample gas pre-treatment unit are shown in Figures 5.2-7 and
5.2-8.
SK-9G01 sample pre-treatment unit can continuously provide the sample gas to SK-3Q04 hydrogen
flame chromatograph for field analysis of well head gas (natural gas samples taken from mud degasser
in the field using the sample pump in the system), the calibration gas obtained using gas sampling bags
is also used to calibrate SK-3Q04 hydrogen flame chromatograph and standard bottle gas or zero air is
also used to check two chromatographs or correct the zero position. The flow diagram of sample gas
pre-treatment unit is shown in Figure 5.2-9.
SK-9G01 sample pre-treatment unit inputs the sample gas provided by engine degasser through the
sample input port inserted in the rear panel of the sample pre-treatment unit by pipeline using the
sample pump, the two valves on the front panel of sample pre-treatment unit are switched to the
Sample gas position. The input port of sample gas on the rear panel of SK-3Q04 hydrogen flame
chromatograph is connected to the output port 1 of sample gas on the rear panel through the pipeline.
The gas sampling bag can be connected to the injection port on the front panel of SK-9G01 sample
pre-treatment unit, the two-position valve is switched to Correction position and the four-position
valve is switched to Injection position; in this way, the calibration gas is supplied from the output port
1 of sample gas on the rear panel to SK-3Q04 hydrogen flame chromatograph for calibration.
Figure 5.2-7 Schematic diagram of the panel of SK-9G01 sample pre-treatment unit
1 Vacuum gauge; 2-Pressure gauge; 3-Planar switching two-position four-way valve; 4-Planar
switching four-position five-way valve; 5-Injection port.
170
Hardware Manual of CMS Mud Logging Unit
Figure 5.2-8 Schematic diagram of the rear panel of SK-9G01 sample pre-treatment unit
1-Five-core socket; 2-Sample vent 2 (connect to non hydrocarbon); 3-Input port of sample; 4-Sample
vent 1 (connect to hydrogen flame);
5-Input port of zero air; 6-Equalizer regulating valve of sample; 7-Input port of standard gas
Figure 5.2-9 Graph showing gas circuit of SK-9G01 sample pre-treatment unit
The standard input port and zero air input port on the rear panel of SK-9G01 sample pre-treatment
unit can be connected with bottle gas and clean zero air, respectively; the two-position valve on the front
panel is switched to Correction position and the four-position valve is switched to Correction and
Zero air positions, respectively; in this way, the gas can be supplied from the output port 1 of sample
gas on the rear panel to SK-3Q04 hydrogen flame chromatograph for verification and zero correction.
Connection
Sample gas degassed from the degasser, dried and filtered zero air and standard bottle gas
are connected to the sample input port, zero air input port and standard input port on the
rear panel of the instrument using pipes;
171
Hardware Manual of CMS Mud Logging Unit
The output port 1 of sample gas is connected to the input port of sample gas on the rear
panel of SK-3Q04 hydrogen flame chromatograph using pipes;
Five-core control socket of SK-3Q04 is connected to the five-core socket on the rear panel
of instrument using cable conductors.
Method of application
Pressure adjustment
When the two-position and four-position valves are at the Sample gas position, adjust the
equalizer valve on the rear panel to make the indicating value of pressure gauge up to about 0.04MPa.
Gas circuit selection
When the sample gas (gas from engine degasser) is used for analysis, it is required to switch the
two-position and four-position valves to Sample gas position, operate buttons on the panel of
SK-3Q04 hydrogen flame chromatograph to turn on the sample pump and then the indicating
value of pressure gauge on the panel of instrument shall be about 0.04MPa; in this way, the
sample gas is suctioned and at the same time, the sample gas is outputted from output ports 1 and
2 of sample gas.
When the standard sample gas (bottle gas) is used for verification, it is required to switch the two-
position and four-position valves to Correction position, operate buttons on the panel of SK-
3Q04 hydrogen flame chromatograph to shut down the sample pump and open the valve of
standard gas sample bottle, open the pressure reducing valve until the output pressure is 0.1-
0.15MPa, and then the indicating value of sample gas pressure gauge on the panel of instrument
shall be about 0.04MPa; in this way, the standard sample gas can be obtained at output port 1 of
sample gas and no sample gas is outputted at output port 2 of sample gas. Please note that the
sample pump is at the shutdown status.
When zero air is used for zero correction, operate buttons on the panel of SK-3Q04 hydrogen
flame chromatograph to shut down the sample pump and then switch the four-position valve to
Zero air position; if the two-position valve is switched to Correction position, then the
indicating valve of sample gas pressure gauge on the panel of instrument is about 0.04MPa and in
this way, the zero air is obtained at output port 1 of sample gas and no sample gas is outputted at
output port 2 of sample gas; if the two-position valve is switched to Sample gas position, then
the indicating valve of sample gas pressure gauge on the panel of instrument is about 0.04MPa
and in this way, the zero air is obtained at output ports 1 and 2 of sample gas. Please note that the
sample pump is now turned off.
When the calibration gas (air bag gas) for injection port is used for calibration, it is required to
switch the two-position valve to Correction position and the four-position valve to Injection
position, then the sample gas is connected from the injection port on the front panel; operate
buttons on the panel of SK-3Q04 hydrogen flame chromatograph to turn on the sample pump and
then the indicating value of pressure gauge on the panel of instrument shall be about 0.04MPa; in
this way, the air bag gas is suctioned, the injected sample gas is obtained at output port 1 of
sample gas and no sample gas is outputted at output port 2 of sample gas. Please note that the
sample pump is now turned on.
Operational positions of the instrument to handle statuses of different gas samples such as Gas
degassed from mud, gas sampling bag (injection), zero air and standard sample gas are as
follows.
Table 5.2-1
Injection method Position of two- Position of four- Status of sample Output port Output port
position six-way position five-way pump 1 2
valve valve
Gas degassed Sample gas Sample gas Sample pump is Available Available
from mud turned on.
Gas sampling bag Correction Injection Sample pump is Available Unavailable
(injection) turned on.
172
Hardware Manual of CMS Mud Logging Unit
Zero air Correction/sample gas Zero air Sample pump is Available Unavailable
turned off. /available
Standard gas Correction Correction Sample pump is Available Unavailable
sample turned off.
Failure and Elimination
The vacuum gauge displays a value of certain quantity, indicating sample gas may be
blocked and it is required to check the blockage of sample gas input pipeline.
The displayed value of the pressure gauge is incorrect when using: probably indicating the
sample pump works abnormally and it is required to check whether the hydrogen flame
analyzer powers the sample pump normally; it may indicate the adjusting rod of equalizer
value is loose and it is required to check and re-adjust the pressure; the sample pump
discharge is inadequate and it has exceptional noise and it is required to clean the pump
diaphragm.
The gas sample is input but no gas sample is output: it may indicate gas leakage in the
pipeline, it is required to check leakage and deal with it; it may indicate the two-position
valve (six-way valve) or four-position valve (five-way valve) is not switched to the
designated position and it is required to check and switch it to the designated position.
While using normally, there should be about 600mml/min gas outputting at output port 2 of
sample when the two valves are at the sample gas position, which can be observed on the
rotor flowmeter on the front panel of SK-3R03. If the flow is incorrect, indicating that there
exists gas blockage at output port 2 of sample gas, so the filter element should be replaced
in time.
Notice
When the standard sample gas (bottle gas) is used to calibrate and the zero air is used to
correct, it is required to operate on the panel of SK-3Q04 and shut down the sample pump
of SK-9G01 to avoid damaging the sample pump and prolong its service life.
When the sample gas is injected for calibration using the injection port, please switch the
two valves to sample gas position immediately to avoid damaging the sample gas and
prolong its service life.
To protect the instrument, cup-shaped filter elements are placed in inlet and outlet of some
pipes: adapter of input port of sample gas, adapter of input port of zero air, adapter of input
port of standard gas, adapter of injection port, in the internal gas lock block of instrument
(connect to nylon hose at the output port of sample pump); users shall often replace these
filter elements as appropriate.
When the gas from steel cylinder or other high-pressure gas storage device is used as input
gas, the output pressure of steel cylinder or other high-pressure gas storage device shall be
controlled below 0.4MPa to avoid exceeding the usable range of two-position and four-
position valves which will affect its normal operation of instrument.
Instrument overview
In SK-3Q04 hydrogen flame chromatograph, one flame ionization detector (FID) is connected
to the rotary valve switching system and used to determine the component gas from methane to
pentane; another flame ionization detector is connected to the flow of sample gas taken from
the degasser and directly determines the total quantity of hydrocarbon gas.
Shenkai high-efficiency 1360 series chromatographic analytical column can effectively
separate C1-C5 components in oil and natural gas.
The layout of SK-3Q04 panel (see Figure 5.2-4) is concise: 10.4-inch TFT display with touch
screen, VMS injection port, carrier gas pressure gauge and sample gas pressure gauge. All the
dialogues are conducted through touch keyboard display. Large-screen TFT display can display
much information such as analysis status, control process, FID operation and chromatographic
data processing, qualitative and quantitative process, analysis results and chromatograph charts
etc.
173
Hardware Manual of CMS Mud Logging Unit
SK-3Q04 system consists of hydrogen flame chromatograph unit and SK-9G01 sample gas pre-
treatment unit and therefore, the input and output connections on the rear panel and inlets of
sample gas, air and hydrogen gas etc shall be purified strictly and it is required to provide pure
and dried gas sources for SK-3Q04 system. All the outlets of gas circuit (blowback emptying,
excessive sample gas blow-off, blowback blow-off of hydrogen gas flow and so on ) leads
outdoors through the overall outlet of comprehensive logging instrument (or geologic logging
instrument, truck-mounted gas instrument. At the same time, the input connection of electric
circuit and single input & output connected to the outsides are available on the rear panel. The
flow diagram of sample gas pre-treatment unit is shown in Figure 5.2-9.Gas circuit control
graph of analytic unit (Figure 5.2-10).
(e) Installation
Each SK-3Q04 hydrogen flame chromatograph shall be connected according to requirements in
Figure 5.2-11.
In the schematic diagram, the dash-line connection is for electric circuit (including signal line and
AC 220V power supply) and the solid-line connection is for pipeline. In the schematic diagram, the
printer is optional (HP3820 printer is used in the figure) and due to rapid upgrading of printers, the
optional printers is required only to comply with PLC3 protocol of HP Company for DOS printing.
174
Hardware Manual of CMS Mud Logging Unit
Figure 5.2-11 Schematic diagram for connection of 3Q04 chromatograph and SK-9G01 pre-treatment
unit
175
Hardware Manual of CMS Mud Logging Unit
12.The Status monitoring in the bottom of TFT screen is used to check whether parameters
such as temperature of chromatographic column, pressure of sample gas and flow rate of carrier
gas etc conform to expected values or not (press Status key of touch screen twice using the
operation pen). To avoid misoperation, (press Keylock key to unlock), related keys of touch
screen works only after pressing them twice, as shown in Figure 5.2-13.
Status
176
Hardware Manual of CMS Mud Logging Unit
observe them and unnecessary to change the default values frequently to avoid not finding the correct
operation parameters.
After heating less than one hour, as shown in Figure 5.2-13, the temperature of
chromatographic column is up to 80 and when reaching the set values of carrier gas and air,
the measurement program will automatically ignite FID assessor and continuously ignite until
total hydrocarbon FID and component FID are ignited (in Figure 5.2-12, the fire display in the
lower right changes from blue X to red fire).If operators forget to turn on air compressor or
hydrogen generator, it is impossible to ignite two FIDs; if operators come across the
situations above, they shall open the switch of air compressor or hydrogen generator
immediately. A few minutes after FID is ignited, the system switching valve of SK-3Q04
switches automatically (if the temperature of chromatographic column is not up to 80 or
there exist deviations in temperature control, the switching valve cant switch). Turn on the
sample pump, then the total hydrocarbon and component begin to pursue baseline in working
mode of awaiting orders (as shown in Figure 5.2-14).
If the instrument is in the adjustment mode, it is unnecessary to ignite two FIDs; in order to
protect the instrument, it is unnecessary to continuously emit ignition signal to two FIDs and it
is necessary only to close Heating or Automatic switching in the lower left of main menu
in Figure 6-1.
Sample gas enters the system and the chromatographic graph shown in Figure 5.2-12 appears
(total hydrocarbon gradually rises and the signal of hydrocarbon components appear).
Press View key in the bottom of Figure 5.2-14 (first press Keylock for unlocking), then
windows as shown in Figure 5.2-15 and Figure 2.2-16 will appear.
If it is required to conduct concentration calibration, conventional setting and advanced setting,
etc. on analytic results, continuously press the triangular key shown in Figure 5.2-14 twice.
Then the system enters the windows as shown in Figure 5.2-18, 5.2-19 and 5.2-20.
If the instrument is in the repair or waiting status, the ten-way switching valve of flow cannot
switch and it is necessary to press the TOGGLE key in the bottom of Figure 5.2-17 and here
the switching value switches manually.
In the instrument system, totally same functional keys are available in different windows, for
example, Toggle, Heat, Pump, Ignite, View and so on. Their definitions are same.
Attention: when the system is of constant temperature, the prompt alarm of Carrier flow rate has
not reached rated value (Figure 5.2-17) will be given if the flow rate and pressure of carrier gas are not
up to their set values. You can press OK to close the window and it will not pop up; if your press
Cancel, the display will appear again in the next cycle. If data not uploaded in the database are up to
80% of its capacity, the prompt of The database is up to 80% will be given. Press OK to close. If
you dont want to display this prompt window any more, you can select to transfer the latest file.
178
Hardware Manual of CMS Mud Logging Unit
Concentration calibration,
check baseline, advanced
setting and conventional
setting etc
179
Hardware Manual of CMS Mud Logging Unit
Figure 5.2-15 View I of total hydrocarbon (green line) and component curves
Figure 5.2-16 View II of total hydrocarbon (green line) and component curves
180
Hardware Manual of CMS Mud Logging Unit
181
Hardware Manual of CMS Mud Logging Unit
4 Overheat Heat the constant temperature oven of chromatographic Red (stop heating)
column to make it over 5 of the set temperature.
5 Normal Stop heating the constant temperature oven of Blue
temperature chromatographic column
6 Preheat The constant temperature oven of chromatographic column is Green
in the course of heating.
7 Fire FID flame has been ignited. Red
8 Fire FID extinguished Blue
9 Lag depth Well depth data (lag depth) transmitted by CMS Numerical value
Attention:
Press OK key after inputting corrected data of concentration. This system has two analysis cycles
of 30s and 90s. The corrected data of total hydrocarbon are universally used in two analysis cycles.
But however, those of components at 30s and 90s cannot be used universally and it is required to
re-correct using standard gas samples where it is accurately quantitative. Input corrected data of
total hydrocarbon and components in the two cycles.
First determine the type of gas to select Concentration/voltage data and the sequence to
Select for data correction determined by the instrument is: methane, ethane, propane,
182
Hardware Manual of CMS Mud Logging Unit
isobutane, normal butane, isopentane, normal pentane and total hydrocarbon (eight options in
total), input according to this sequence or input at random; if you input at random, you can
press Sort to automatically sort from low concentration to high concentration. Press and
Select will sort gas in reverse direction, namely: total hydrocarbon, normal pentane,
isopentane, normal butane, isobutane, propane, ethane and methane. In the bottom of the
window shown in Figure 5.2-18 are 0-9, , digitals, BK key (backspace key) and default key.
It is required to press OK after finishing the data input, showing data has been confirmed by
the measurement control computer. Calibration data can be printed by a printer.
Example of total hydrocarbon calibration: as shown in Figure 5.2-18, first Select, press the
triangular key to select total hydrocarbon (TH); in the blank boxes, the left are concentration
and the right are peak areas (in fact, they are voltage values for total hydrocarbon), you can
select analytic results of eight concentrations in the blank boxes. First press DEFAULT key in
Figure 5.2-18 and here data will appear in the blank boxes. Now inject samples and you can
obtain analytic results of total hydrocarbon at concentrations of 0.01%, 0.1%, 1%, 5%, 10%,
50% and 100%, respectively; if the analytic results of total hydrocarbon are values in ppm, you
can multiply them by 100 to convert to mv (for example, obtained analytic result at the
concentration of 10% is 10%, multiply 100 and you obtain 1000mv); by analog, you can obtain
analytic results (converted) at different concentrations and input them in the table in Figure 5.2-
18.After finishing the data input, input data above are valid only after pressing OK key.
Example for component calibration: the calibration method of component is the same as that of
total hydrocarbon but conversion is not required, you can directly input peak areas of different
concentrations in the table in Figure 5.2-18, but it shall be noticed specially that components
include C1-C5 different compounds and it is required to determine Select at corresponding
compound (pressing the triangular key to select different compounds) before inputting data.
After inputting data of a compound, input data are valid only after pressing OK key.
Analytic calibration shall be tested with standard samples. Prepare 10 standard samples of
0.01%, 0.02%, 0.5%, 1%, 2%, 5%, 10%, 20%, 50% and 100%.At least, 4 standard samples of
0.1%, 1%, 10% and 100% shall be prepared and other 6 samples are prepared manually using
these 4 standard samples. For manual preparation, only one preparation is allowed. To ensure
data accuracy, keep dilution factor within 5:1.Testing with standard samples improves data
reliability and also enhances the authority of data interpretation. The test begins with the
concentration of 0.01%, increase the concentration in turns and obtain results of C1 at different
concentrations at the workstation. After finishing sample injection, this group of data is input to
3Q04 for chromatographic calibration (shown in the correction window of components or total
hydrocarbon in Figure 5.2-18), and the input method is as follows: You can directly input
concentration (%) and peak area value (mvs). There are at most 8 groups of data for the voltage
value corresponding to the input concentration. The software will automatically calculate
correlation coefficient, intercept and slop of this channel.
Attention: when conducting the linear test, care must be taken to prevent cross contamination
between samples of different concentrations. It shall be noticed that samples of low concentrations
are injected first and then samples of high concentrations are injected gradually; in the case a
sample of high concentration such as 100% is injected by mistake, it is required to flush using pure
air or set the program of fast chromatograph at automatic injection status and drive the residual
sample gas out after customized switching for several times. Switch until no signal appears for
inject of empty switch (the signal value is within the detection limit).
183
Hardware Manual of CMS Mud Logging Unit
184
Hardware Manual of CMS Mud Logging Unit
185
Hardware Manual of CMS Mud Logging Unit
186
Hardware Manual of CMS Mud Logging Unit
Data printing
3Q04 hydrogen flame chromatograph has the printing function attached to the instrument and it
can slowly and quickly print chromatographic graphs, time-sequence of chromatographic information of
60min/180min (total hydrocarbon, baseline, C 1, C2, C3, iC4, nC4, iC5 and nC5) and calibration curves of
total hydrocarbon/ component in real time. The data printing function is an auxiliary function.
Generally, data are saved in the database in the electronic disk and printed data are presented only as
another presentation in the field.
187
Hardware Manual of CMS Mud Logging Unit
Adjust baseline
When 3Q04 hydrogen flame chromatograph runs at high sensitivity (low concentration), the
instrument has baseline correction function, namely, BasAdj appears in the panel; when press
BasAdj, the analysis cycle is corrected automatically five times by the baseline, BasAdj pops up
automatically. Press BASCOM key and the high-sensitivity analysis is conducted in the next cycle.
It shall be noticed after correction in the analysis cycle of 90s, it is required to correct again when
switching to the analysis cycle of 30s, and that is to say, two sets of correction programs are available
for analysis cycles of 30s and 90s.The analysis cycle of 90s is selected in the course of logging and that
of 30s is selected when approaching to target strata.
VMS operation
Automatic VMS operation
When conducting the VMS operation, shut down the sample pump, insert the injection needle
into VMS port on the panel of 3Q04 analytic system, then take samples from thermovacuum
degasser using an injector (the sample quantity is 2-5ml), homogenously and slowly push the
injector in the VMS port (through the injection needle) 5s before the instrument switches from the
blowback status to analysis status. When the program enters the analysis status, draw out the
injector and finish the automatic VMS operation.
Manual VMS operation
When conducting the manual VMS operation, shut down the sample pump; in the
conventional setting in Figure 5.2-19, close the automatic switching to make the analytic system at
the manual switching status, insert the injection needle into VMS port on the panel of 3Q04
analytic system, then take samples from thermovacuum degasser using an injector (the sample
quantity is 2-5ml), homogenously and slowly push the injector in the VMS port (through the
injection needle) when the instrument is in the blowback status, press TOGGLE key in Figures
5.2-17, 5.2-19 and 5.2-20 to switch to the analysis status, draw out the injector and finish the
manual VMS operation.
Attention: please shut down the sample pump when conducting the VMS operation, and draw
out the injection needle (make the VMS port sealed) when VMS operation is not conducted.
(g) Maintenance
Gas source
SK-3Q04 hydrogen flame chromatograph is an exact analytic instrument used in the petroleum
exploration field and it should be maintained with care when it is used.SK-3Q04 chromatograph
contacts many external gas sources, which is the emphasis of routine maintenance.
SK-3Q04 hydrogen flame chromatograph mainly includes two facilities to supply hydrogen gas
and compressed air. In addition, the sample gas taken from the petroleum exploration field is also
available for the chromatograph. All the gas sources should be dried and filtered strictly. Hydrogen gas
and compressed air are dried using allochroic silicagel and for the compressed air, it is required to add a
segment of active carbon to the allochroic silicagel to absorb the oil in the compressed air. The filter of
below 10u should be added before entering the chromatograph to prevent dust from entering the
chromatograph.
After pumped out from the degasser, the sample gas first enters the anti-blocking device to prevent
mud from pumping out. Secondly, the anhydrous calcium chloride is used as the drying agent. After it
enters the logging instrument through the pipeline, a segment of drying agent of anhydrous calcium
chloride is added. The filter of below 10u should be added before entering the chromatograph to prevent
dust from entering the chromatograph. The allochroic silicagel is absorptive and cannot be used as the
drying agent.
It is required to check the drying agent every day and often replace it. If the water vapor enters the
chromatograph, it will give rise to instability of instrument and shorten its service life.
188
Hardware Manual of CMS Mud Logging Unit
Attention: if the gas circuit is choked by small particles such as dust, organic impurity and
mechanical impurity etc, it will give rise to abnormal operation of instrument and inaccurate
measurement and even shorten the service life of instrument. In order to prevent this phenomenon, it is
required to place a filter in the front end of gas circuit; much impurity is contained in the sample gas and
therefore, the filter shall be replaced regularly.
The filter of sample gas in the chromatograph is replaced every three months. However, it is
required to check the filter and replace it immediately if the sensitivities of components and total
hydrocarbon become lower at the same time. A filter should be placed before the gas inlet joint. For
replacement, refer to Figure 5.2-24.
Joint
O-shaped ring
Spring
Cup-shaped filter
to be replaced
M4 screw
Spring washier
189
Hardware Manual of CMS Mud Logging Unit
it by manual switch. It is unnecessary to adjust if the full-scale voltage is in the range of 9.0-10.5V; if
beyond the range, adjust the corresponding full-scale potentiometer of SK-3Q04 to make the full-scale
voltage of potentiometer in the rang of 9.0.0-10.1V.+3Q04 quantified by peak area and the peak height
is used as reference.
Power supply
SK-3Q04 hydrogen flame chromatograph uses a very simple power supply, but the dynamic
analysis range of SK-3Q04 hydrogen flame chromatograph is very large, up to over five decimal
numbers and more or less, the noise caused by power supply will affect the analytic precision. We get
accustomed to recording original data using a linear recorder but however, the linear recorder is prone to
interference of power supply noise and burr or white noise is superposed in the output curve, affecting
the quality of data. For this reason, the chromatograph system is expected to work under clean and
stable power supply conditions. At ordinary times, we purify the utility power and add a voltage
regulating device if required. The frequency of utility power is generally stable line frequency and thus
the effect of frequency is not considered.
Table 2.2-3
Switching power
supply SPS A100-122 12V /1A, +12V /2A, 5V/6A
R type transformer 50V /0.2A, +17.2V /1.5A, 4V/ 5A, +17.2V /0.22A, 11V/0.2A
When it is used in the petroleum exploration field, the effect of diesel generator cannot be
ignored.SK-3Q04 chromatograph system should be powered by UPS. The frequency of power supply
should be kept at 501Hz as much as possible. Over large frequency deviation will give rise to evident
decrease in efficiency and increase in heat of equipment such as generator and transformer etc and it
will directly cause system failures. It should be connected to ground to avoid over large current of
ground line.
Integraph/ recorder
SK-3Q04 reserves interfaces of integraph / recorder for users but it has certain maintenance
requirements for operators.
The analysis speed of SK-3Q4 is fast, so the recorder should use relatively fast chart speed and
operators shall check pen and paper every day. The recorder paper exposed to moisture is prone to
deviating or stopping. Rapid peak output is more likely to cause this phenomenon and frequent check is
required.
For fast analysis, the integraph / recorder will output many records every day and it is required to
appropriately deal with the paper outlet to prevent paper from filing up.
TFT liquid crystal screen and touch screen
Notices for using TFT liquid crystal screen and touch screen
Protect the surface of touch screen. The touch screen is a relatively delicate display and
operation control system. When maintaining and using, users shall operate by operation pen of
touch screen or clean hand and it is forbidden to touch the surface of touch screen by dirty
hand; therefore, dont contaminate or damage the display screen or touch screen when
maintaining them.
Notices for operating
TFT liquid crystal screen is assembled through elaborate design, so please dont assemble and
unassembled the screen at will. TFT liquid crystal screen and touch screen shall be maintained
by professional technicians or under their directions.
Dont assemble and unassembled the external metal frame to avoid damaging TFT liquid
crystal screen and touch screen.
Dont scuff the touch screen using hard or cute parts.
Notices for maintenance of TFT liquid crystal screen
190
Hardware Manual of CMS Mud Logging Unit
The connection between the liquid crystal screen and the main board shall be bound firmly
and socket connector shall be inserted accurately to their designated positions, otherwise over-
current and over-voltage may be caused, damaging the elements of the liquid crystal screen.
The working temperature of liquid crystal screen is 0-45 and its saving temperature is -20-
+60 and it cannot be used or stored beyond the limit storage temperature; if the temperature
is lower than the crystallization temperature, the liquid crystal will crystallize and the
directional layer is damaged, making parts failed; if the temperature is too high, the liquid
crystal will become isotropic, losing the liquid crystal phase and accordingly, it loses the
function of liquid crystal parts.
When the backlight is on but no character is displayed on the liquid crystal screen, dont pull
and plug connectors with power on , otherwise the liquid crystal screen will be burnt out. It is
forbidden to squeeze the liquid crystal screen by acute objects to avoid scuffing the surface of
screen or other dispensable damages. If the signal connecting wire of liquid crystal screen and
adapter on the bias plate of inverter break off, they shall be connected correctly according to
the wiring diagram. The output voltage of liquid crystal screen cannot exceed 22V, otherwise
the liquid crystal screen may be burnt out.
(h) Failure diagnosis and elimination
Failure to ignite automatically
The measurement control system is not set at automatic switch. Please refer to conventional
setting window and activate Automatic switch.
The temperature doesnt reach the preset value (in warm-up status).After the temperature
reaches its preset value, the measurement control system will give an ignition command.
Failure to ignite
Hydrogen generator is not opened.
Air compressor is not opened.
Remove the lid of upper cover of assessor and observe whether the ignition wire is burnt red or
not in the case of automatic igniting. If the ignition wire is burnt red, the measurement control
system is in normal operation.
If the ignition wire is not burnt red, measure whether 4V ignition voltage is available or not at
the two wire-connecting terminals.
Voltage available:
Is the ignition wire broken?
Whether the ignition wire contacts poorly with wire-connecting posts.
No voltage
The ignition wire is broken.
The connector lug is loose.
The ignition fuse is broken.
Air inspection
Measure the flow rate of combustion-supporting air and it should be in the range of 700-800ml/min
(total hydrocarbon FID and component FID); if the flow rate is too large, it is difficult to ignite and the
reason is that the hydrogen gas will be diluted due to too large flow rate of air, giving rise to abnormal
ignition of FID.
Flow rate of hydrogen gas
What is directly related to FID ignition is flow rate of hydrogen gas. In the control status display
window, the flow rate of hydrogen gas (carrier gas) is digitally displayed directly and the displayed
value is over 60ml/min (the analysis cycle of 30s), the flow rate is small and thus it cannot ignite
normally.
In the normal status, the instrument has been adjusted when leaving factory and it is unnecessary
for uses to adjust (related parameters such as temperature and flow rate etc).
191
Hardware Manual of CMS Mud Logging Unit
Switching extinguishment
Check whether the flow rate is 80ml/min (about) or not in two statuses: analysis and sampling
statues. If one flow rate is especially small, it will result in switch extinguishment. Please check
whether gas leakage may occur in one of two statuses.
The switching value is of no force when switching and it takes long time, giving rise to
instantaneous interruption of hydrogen gas in the assessor when switching.
The air leaks in a large area and hydrogen gas cannot burn sufficiently, giving rise to
extinguishment due to lack of oxygen when switching suddenly. It is required to monitor the
pressure gauge on the panel of instrument.
Extinguish occasionally without special reasons
Occasional extinguishment is generally caused by unstable flow rate of hydrogen gas or
combustion-supporting air in the pipeline and it is seldom found. If this phenomenon appears, it is
required to find out where gas leaks or is blocked in the analysis process. Sometimes, it is very difficult
to find out slight amount of gas leakage or blockage and you can step up the supply gas pressure and
comparison with the flow rate parameter in the original record of instrument will help to find out where
gas leaks or is blocked.
Working gas pressure is unstable.
Whether the supply gas source complies with the range of pressure. The equalizer valve of
chromatograph itself works normally only in a certain range of gas pressure and each level of
hydrogen gas circuit can work only in the pressure difference of over 0.07-0.1MPa and for air,
the pressure difference is over 0.15MPa.Over high supply gas pressure not only makes the
equalizer valve out of effect but also damages the equalizer valve.
The sample gas is pressurized by the sample pump itself, which, in combination with the
attenuation of long pipeline, making the post-pump pressure not very high. If serious gas
leakage occurs in the post-pump sample gas pipeline, the post-pump pressure will drop and it
cannot meet the requirements of pressure difference for equalizer valve. The sample jump is
used for a long time and the rubber diaphragm will deposit dust or age, which also gives rise to
drop in post-pump pressure.
Over large attenuation of long sample pipeline and agglomeration of calcium chloride due to
influence with damp in the drying cylinder may aggravate the load of sample pump, giving rise
to insufficient post-pump pressure and finally, the pressure of sample gas is unstable. When the
mud degasser and sample gas etc are blocked, the vacuum gauge of SK-9G01 will indicate the
pressure (the vacuum gauge will not indicate under normal conditions) and it is required to
check the sample gas pipeline for blockage.
The baseline has burr or its noise is large.
The supply gas source is not dried well and the working gas is too damp. It is required to
replace the drying agent.
FID nozzle is dirty, giving rise to unstable flame and jump spark. It is required to clean the
nozzle.
The assessor itself is dirty and the insulation resistance drops. It is required to clean it.
Whether the condensation water is found or not in FID. Electric leakage causes decrease in
insulation of FID, results in baseline noise and burr.
The ion wire is poor (insulation drop or electrical leakage gives rise to unstable signal). It is
required to replace the ion wire.
Much dust is accumulated inside the electrometer or electrometer is exposed to serious
moisture. It is required to clean and dry it in the shade.
The flow rate of hydrogen gas is over large at the nozzle and the temperature of assessor is over
high. It is required to adjust the gas flow and check the reason for over large flow rate.
Baseline drift is large.
192
Hardware Manual of CMS Mud Logging Unit
The chromatographic column and pipeline system are contaminated by heavy components. In
this case, it is generally found after the matters such as gasoline, diesel oil and drill fluid
cement etc are absorbed and the chromatograph can separate component peaks after a long time
by manually injecting sample. It is very difficult to deal with this case. The general practice is
to enhance blowback and stop injecting sample. Contamination will become less serious or
even disappear after long-time blowback. If there is no sufficient materials and time, you
cannot disassemble pipelines and clean them.
The working gas source is too damp and it will accompany with burr or noise and it will
become normal automatically a while later after replacing the drying agent.
The assessor itself is dirty and the insulation resistance drops. Cleaning is required.
The blow-off gas of chromatograph is not discharged outdoors and the content of organic
matter in the air increases.
Much dust is accumulated inside the electrometer or it is exposed to serious moisture. It is
required to clean and dry it in the shade.
The chip of electrometer is poor and it should be replaced.
Components are separated poorly.
The flow velocity of carrier gas is over large, giving rise to decrease in the efficiency of
chromatographic column and it is required to reduce the flow velocity.
The temperature of column oven is over high and it is required to find out reasons for over
temperature.
The peak output is too fast and it occurs often together with over large flow velocity of carrier
gas.
The chromatographic column is contaminated and should be replaced.
The chromatographic column fails due to use for a long time and it should be replaced with a
new chromatographic column.
Air leaks in the pipeline and it is required to repair the gas circuit.
Whether the gas circuit leaks or is blocked. It is required to repair the gas circuit.
When the above methods are not effective, it is recommended to buy another set of Shenkai
1360 series fast chromatographic column.
The peak output time of component is too long.
The flow velocity of carrier gas is too small and it is required to re-adjust and increase the flow
velocity.
The temperature of column oven is too low and it is required to find out reasons for temperature
loss.
The supply gas pressure of carrier gas is too small.
The carrier gas is blocked or leaks and it is required to repair the gas circuit.
The calibrated peak output drops down.
The sample gas lock is blocked or a slight amount of gas leaks at the joints. It is required to
repair the total hydrocarbon gas circuit. The working flow rate of total hydrocarbon is very
small and slight amount of gas leakage will give rise to decrease in the sensitivity.(Total
hydrocarbon only)
The over large or small flow rate of carrier gas will cause drop-down of peak output. When the
flow rate of carrier gas is over large, the sensitivity of assessor will decrease; when the flow
rate of carrier gas is over small, the peak output will widen and the peak height will also
decrease.
There are mistakes in manual preparation and sampling methods and samples of the same
concentration can be analyzed by several persons and then compared for verification.
The pressure-reducing valve of sample gas cylinder is poor and no gas taken for a long time
will also give rise to dilution of sample gas inside the pressure-reducing value. It will become
193
Hardware Manual of CMS Mud Logging Unit
Instrument structure
The embedded SH-3H02 infrared analyzer consists of chassis, optical components (light source,
gas chamber and detector), dust filter, flowmeter and electronic components.
There are power switch, indicator for temperature control, pointer or digital concentration display
meter head, dust filter, pump switch, zero point and span potentiometers and gas flowmeter on the front
panel of the instrument (alarm function and II-level measuring range are provided according to needs).
During circuit design of instrument, zero point potentiometer and span potentiometer are
independent, so is their adjustment. When correcting, please adjust zero point before adjusting span.
There are inlet and outlet for gas to be measured, power socket with filter, fuse and the output
signal plug on the rear panel of the instrument.
Instrument installation
Before taking out the instrument from the packing box, it is necessary to check whether the
packing box has been damaged or not. It should be careful in transportation.
Open the box to check the appearance for any damage.
The placing site and installation of the instrument
When the instrument is used for flow analysis, SK-3H02 infrared analyzer should be installed close
to sampling point as much as possible to reduce lag time. Or large flow flow-distributing sampling is
adopted to reduce lag time resulting from over-long sampling pipe. The instrument should be installed
in dry and clean environment with good ventilation. Ambient temperature is 0-40 and relatively
humidity is less than 90%, avoiding direct sunshine.
The highest ambient temperature for using instrument is 45 . When the temperature is more than
40, the specified measuring accuracy and error limit cant be ensured. At the same time, working in
high-temperature condition for a long time will shorten the service life and maintenance cycle of the
instrument, as the service life of instrument components will reduce with the increasing of the
temperature. When choosing the installation site of the instrument, avoid strong vibration that may have
influences on the instrument.
This instrument belongs to non explosion-proof electric equipment. Therefore, use in places prone
to explosion is prohibited. To install it using dial plate, place the box body in the opening hole of the
dial plate and use a mounting plate to lift it. Fix the instrument with four M6 screws.
Gas circuit connection
Inlet and outlet nozzles of gas to be measured are available on the real panel of the instrument.
Generally, flexible hose can be used for connecting. Please tell us your special requirements for
connecting with the sampling system, if any, while you placing order.
Gas pre-treatment
To prevent the sample chamber of the analyzer from pollution and obtain correct analysis results, it
is very important to correctly select sampling points and gas pre-treatment devices. Sampling point
should be selected in places where gas concentration is representative.
The measured gas will pass through the filter for removing the dust in it. After the measured gas
with high-humidity and temperature higher than room temperature passes through analysis lab,
condensation will occur, which can be eliminated by adopting the method of heating the filter and
sample pipe, or adding a steam separator to separate the water from the sample. To separate small
waterdrop, it is necessary to use gas condenser-compression condenser or semiconductor thermopile
condenser. For viscous components such as coal tar etc. in the measured gas, it is required to select or
design special devices to separate the viscous components. For some special non measured components
with strong disturbance in sample, it is required to use proper chemical method to remove them.
Gas circuit installation
The measured gas pipe connected to the analyzer should be short as much as possible to reduce lag
time. If the lag time of measuring results is too long, large flow bypass sampling should be used. The
installation of the sampling pipe should be such that no condensed water is accumulated in the pipe. If
196
Hardware Manual of CMS Mud Logging Unit
condensation occurs, a separator or a gas condenser should be installed at the lowest point of the pipe
before the analyzer. If the ambient temperature of the sampling pipe is below zero degree, the sampling
pipe should be heated to prevent water accumulation and freezing from blocking the pipe. In a word,
uses are advised to select pre-treatment device according to actual conditions.
Power supply connection
One end of power cable of the instrument is CEE standard plug and the other end 5A/250V
triangular plug with safe grounding contact. Connect phase, neutral and ground lines of power supply
correctly.
Measuring and recording instrument ground connecting
The measurement output of the instrument is 0-20mA (or 4-20mA) direct current, and the
maximum load is 600. When voltage output is needed, it is required to select correct reducing
resistance to connect to the instrument.(The instrument can be connected before leaving factory
according to user requirements).
Instrument startup
Check heating control
After power on of the instrument, the temperature control indicator on the front panel should light
up, indicating that the instrument is heating. After about 15 minutes, the temperature control indicator
begins to flash. After two or three hours, the optical system of the instrument can reach constant
temperature. Zero point and span correcting as well as measurement can be performed. The constant
temperature point of the analyzer has been adjusted to 47 before leaving factory, and the users cant
change the constant temperature point at will. If the constant temperature of the instrument needs to be
measured, a contact thermometer can be used to measure the temperature of the detector socket.
The over-temperature protection measures of the instrument: when the temperature exceeds 53
and even reaches 70 due to malfunction of the temperature control. The bimetal switch will cut off to
power off the heating board and stop heating. Generally, after the instrument is preheated for two or
three hours, zero point and span correcting as well as measurement can be performed.
Adjust zero point
Close the pump switch, and feed zero point gas (high-purity nitrogen gas) to the instrument, then
adjust the flow to 0.5L/min.If the zero point gas is released from the steel cylinder with pressure
reducing valve, use the pressure reducing valve to adjust the pressure at the instrument inlet to make the
flow reach 0.5L/min.The maximum pressure at the instrument inlet is 20KPa.The constant instruments
apart from measuring carbon dioxide can use air for zero setting, namely, turn on the pump switch to
extract the pure air to the instrument through air nozzle. After one or two minutes, use a small clock
screwdriver to adjust the zero point adjusting potentiometer on the front panel to make indicating value
of the instrument at zero point.
Adjust span
Use standard gas to adjust instrument sensitivity.
After finish zero point adjusting of the instrument, turn off the pump switch, and feed standard gas
of known concentration (70-100% of the measuring range) to the instrument. The flow rate is 0.5-
1L/min. Use a small clock screwdriver to adjust the span adjusting potentiometer on the front panel to
make indicating value of the instrument the same as the concentration of the standard gas fed to the
instrument. After span adjusting, measurement can be performed. When measurement is not performed
or in the course of positive pressure sampling, the pump switch should be off.
Notice
On the circuit board of temperature control and power supply inside the instrument, potentiometers
for temperature control adjusting, light source pressure adjusting, phase adjusting, linearization
adjusting and meter head synchronous adjusting have been adjusted before leaving factory, it is
unnecessary for users to adjust. If adjustment is needed in the course of using, it should be done when
the measuring conditions are satisfied. Otherwise, no adjustment should be done to avoid adjustment
197
Hardware Manual of CMS Mud Logging Unit
disorder, making the instrument unable to operate normally or burn out the instrument.
Use and maintenance
In order to ensure the normal operation of instrument, users should regularly check and maintain
the instrument and its sampling system. Instrument maintenance mainly includes checking the safety
filter and dust filter.
For the dust filter on the front panel of instrument, its filter paper is white originally. If it changes
into dark blue or black, it should be replaced; for the safety filter connected to the gas inlet and
outlet in the internal gas circuit of instrument, if it is contaminated, it shall be cleaned with proper
cleaning agent according to the type of contaminants.
If the light source motor produces noise in the course of instrument operation, it is required to
replace the motor. It is forbidden to add oil to shaft and bearing of motor.
Maintenance of sampling system: according to different types of samples treated by sampling
system, it is required to regularly check sampling units such as various filters, cooler and steam
separator of the sampling system, clean or replace them in time to ensure the sampling system to
work normally.
It is required to check and correct the span of instrument once or twice a month. It is required to
check and correct the zero point of instrument once or twice a week.
During the maintenance period each year, it is required to check leakproofness of the internal gas
circuit and sampling system in the instrument.
Trouble shooting
No indication
No. Causes Elimination method
1 The fuse of power supply is broken. Replace 1.5A fuse.
No gas flow (no sample gas goes through the
2 Check the gas circuit and filter of instrument.
flow meter).
Open the upper cover and insulation cover of the
The cable plugs of light source component or instrument and check whether the cable plugs of
3
preamplifier unit are not connected well. light source component and preamplifier
component are inserted firmly.
Open the upper cover and insulation cover of the
The irradiation wire of light source is burnt out
4 instrument and check whether the irradiation wire
or welding spots fall off.
is burnt out and welding spots fall off.
The indication is unstable.
No. Causes Elimination method
Check whether the gas circuit of sampling gas is
1 The flow rate of gas is unstable. blocked and the control of flow rate is out of
operation.
2 Mechanic vibration Improve the environment.
The motor of light source component is out of
3 Replace optical components.
operation.
A 200W AC regulated power supply should be
4 Interference of power supply.
equipped if necessary.
5 Failures of preamplifier or detector. Send to factory for repair.
The indication is incorrect.
No. Causes Elimination method
Gas leakage in the gas circuit. Check the gas circuit of the instrument and filter
1
on the front panel.
2 Maladjustment of zero point or sensitivity. Correct the zero point and sensitivity.
Gas to be measured contaminates optical Unscrew and lift the black cover of optical
3 components. component, blow wash it with high-purity
nitrogen gas and then fasten it.
The indicator of temperature control is off. Check whether the indicator is damaged or not
4 and measure whether 220V voltage is available
at two leading wires of heat plate.
The indicator of temperature control is on. The temperature control circuit is out of control
5
and it is sent to the factory for repair.
6 Gas leakage in the gas chamber. Blow wash the reference edge of gas chamber
with high-purity nitrogen gas and it is required
198
Hardware Manual of CMS Mud Logging Unit
199
Hardware Manual of CMS Mud Logging Unit
Figure 6-1 Appearance of main power switch of the mud logging unit
After the main power switch is closed, three-phase AC power from well site will enter
the logging unit. The three-phase power supply from well site first enters the primary side of
the flameproof transformer and the secondary side outputs three-phase 380VAC to flameproof
control box. The indicator of three-phase power supply at the top of cabinet in the logging unit
lights up (Figure 6-2), and users are required to adjust the universal selection switch on the
panel of the flameproof control box to position 1 (auto) or 2 (manual). The default position is
0 (stop) when the logging unit leaves factory. If position 1 (auto) is selected, the positive
pressure explosion-proof system will be started. If position 2 (manual) is selected, the positive
pressure explosion-proof detection will be ignored and the three-phase 380VAC will be sent to
the distribution equipment (Figure 6-3).For the logging unit is still at the stage of debugging,
users are suggested to select position 2 (manual) temporarily. For the operation method of
activating the positive pressure explosion-proof system, refer to the operation flow of the
positive pressure explosion-proof system.
Figure 6-2 Indicator of three-phase power at the top of cabinet in SK-CMS (if not all of the
three indicator are on, open phase is likely for the external three-phase power).
200
Hardware Manual of CMS Mud Logging Unit
Figure 6-3 Schematic diagram of the panel of SK-CMS mud logging unit flameproof control
box
Warning
Open-phase power supply is not allowed. Both over high and over low frequency and voltage
will have bad influences on the steady operation of the electrical equipment, and even cause
permanent damage to equipment. If the input power supply from well site can't meet the
requirement, users should consider increasing the distribution protection devices.
201
Hardware Manual of CMS Mud Logging Unit
Figure 6-4 Panel and internal circuit of SK-CMS mud logging unit distribution equipment
Figure 6-5 Linkage of leakage protector and C65N (4-link air switch)
202
Hardware Manual of CMS Mud Logging Unit
distribution equipment, switch the selection switch Degasser manual/auto on the panel of
the distribution equipment to Manual and press Degasser on button (green) on the panel
of the distribution equipment, the engine degasser will begin to run. Check whether the
degasser runs well and is fixed firmly. And there should be no relatively great vibration.
Figure 6-6 Schematic diagram of the functional keys of the thermal relay
Attention:
The thermal relay cant reset itself automatically after each action. Only by pressing the
Reset key, can the alarm be disabled. Otherwise, the degasser cant be started again.
Attention:
Unbalanced load distribution can easily cause the neutral point of three-phase power to
203
Hardware Manual of CMS Mud Logging Unit
migrate and make null line live. We have performed accurate calculation on the load equipped
in the logging unit before it leaving factory and distributed it to three-phase live line
balancedly.
204
Hardware Manual of CMS Mud Logging Unit
carbonate in the clastic debris, providing favorable evident of naming of clastic debris.
Its principle: use the container of rated volume as the reaction tank, add 1g debris powder required to
be analyzed and 5ml chlorhydric acid (its concentration is 20%), seal the container to let the debris
powder sufficiently react with the chlorhydric acid. The pressure sensor converts the pressure produced
by CO2 generated from the reaction to the electric signal and then it is converted to 4~20mA current
signal of two-wire system through the transmitter. Then SK-9N11 analog quantity input isolation barrier
is used to conduct various operations of converting the analog quantity to digital quantity and after
passing through the electric isolation barrier at the input and output ends, it is transmitted to the host
computer of system through the CAN node bus and analyzed and processed by the computer.
System computer
Pressure sensor embedded 9N11 node CAN bus
in the reaction tank
CAN communication
Figure 1-1 Composition and signal flow chart of carbonate analyzer system
Pressure sensor
Air vent
Slide
valve
Upper cover of
reaction tank
Cylinder of reaction tank
205
Hardware Manual of CMS Mud Logging Unit
Upper cover
Handle of slide valve
Slide valve
Cylinder bottom
Waist-shaped trough
Add powdery
rock sample
here
Note: powdery rock sample is put into the waist-shaped trough and no powder is sprinkled
into the cone-shaped trough to avoid affecting the analytic precision.
Take an injector, suck up 5ml chlorhydric acid with the diluted concentration of 20%,
inject it into the cone-shaped trough of reaction tank and no chlorhydric acid drops the
206
Hardware Manual of CMS Mud Logging Unit
sample to avoid affecting the analytic precision due to reaction with partial sample.
Screw up the upper cover of reaction tank until O shaped gasket is compacted and
sealed (Figure 1-5);
When screwing up the upper cover, it is required to keep the cylinder horizontal
and balanced to prevent the rock sample from reacting with chlorhydric acid
before the instrument doesnt start to analyze.
When placing the cover, it is required to keep the slide valve of reaction tank in B
position; namely, the air pressure in the tank is balanced with the external pressure.
Push the slide valve to A position (Figure 1-6); (Air vent is between o-shaped rings)
Connect signal wires of sensor
Note:
The clastic debris shall be weighed accurately and the chlorhydric acid shall be measured
accurately.
The reaction tank shall be cleaned after the reaction each time and no remnant is left.
The sample shall be reacted thoroughly.
If it is required to conduct the next operation after finishing an analysis, the reaction tank must be
washed.
B. Operation steps to wash the reaction tank:
Take down signal wires of sensor
Push the slide valve to B position ;
Take down the upper cover of reaction tank;
Conduct the next operation after washing with water.
207
Hardware Manual of CMS Mud Logging Unit
208
Hardware Manual of CMS Mud Logging Unit
analytic data and analysis results of this sample are saved in analytic data table of carbonate and
analytic result table of carbonate, respectively, and users can recall the analytic data any time: input
the well depth of played-back sample in the input box of sampling well depth and then click on call
button. If required, click on print button to output the carbonate analysis report (as shown in Figure 1-
10).
XXX Maintenance
It is forbidden to invert the reaction tank in the course of operation to prevent chlorhydric
acid from enters the sensor to damage the sensor.
If the instrument is not used for a long time, please clean the reaction tank.
The instrument should be stored in the place where the temperature is approximate and is
dry to avoid elements from damaging when it is not used.
When transported, it should be wrapped to avoid damaging the instrument due to
vibration.
content of dolomite.
Curve C: dolomite. The reaction gradually occurs. Finally the content is 79% when the pressure
is stable.
Curve D: Dolomite with .The reaction immediately occurs, but slowly rises and stabilizes on
68%.
211
Hardware Manual of CMS Mud Logging Unit
Technical indicators
Measuring range: 1-3g/cm3
The minimum sample weight: 0.05g
Resolution: 0.03 g/cm3
Fig 2-1: Density analyzer of mudstone
XXXIV Operation and use
When measuring, it is required to use pure mudstone, excluding sandstone, limestone and
other rocks.
Carefully select several new mudstone fragments as samples (new debris from the well bottom
shall be angular and small) in the upstream of vibration screen and it shall be noticed that the mudstone
sample cannot be soaked by mud fluid. Carefully blot up the surface of debris using filter paper (dont
heat), measure its density immediately and dont dry the debris using dry oven or heater.
After add several drops of cleaning agent (or use anionic detergent and soap suds, the purpose
is to lubricate the contact between the upper of stainless steel pole and the water surface to measured
parts no air bubble and water bubble so than correct readings can be obtained)to the pure fresh water,
inject into the organic glass tube, the water surface is about 4cm from the top, put the floater in the
water, no air bubbles are available on the submersed; if available, rotate the floater to eliminate them,
when the floater is stable, its top shall be 1cm at least below the water surface (not more than 2cm), then
press the tray downwards until the damping hammer contacts the bottom, here the tray is 1cm at least
above the water surface, otherwise some water shall be removed.
Measuring method
Before measuring, it is required to adjust zero position and accurately adjust using zero
position knob, shown in Figure 2-2(a).
Put the mudstone sample in the tray, after the damping hammer is stable (cannot contact the
bottom of cylinder), read a scale value L1, shown in Figure 2-2(b), then place the mudstone
sample in the tray on the floater in the water, after it is stable, read a new scale value L2,
212
Hardware Manual of CMS Mud Logging Unit
shown in 2-2(c), the density d of mudstone can be calculated by the following formula:
L1
d=
L1 - L2
Note: measure the position of floater using the graduated scale in the mirror, eye ball, needle point
in the tray and imaging of needle point in the mirror shall on a same horizontal plane when measuring,
and then read corresponding value on the scale.
Figure 2-2
213
Hardware Manual of CMS Mud Logging Unit
For samples to measure the density of mudstone, take a sample by the interval of 5-20m, then blot
up water using filter water and measure the density of each sample using the density analyzer of
mudstone, plot these values according to well depth on the coordinate grid of well depth vs density log;
it can be seen that the density of mudstone increases as the well depth increases under conditions, for
example, the normal density trend line of mudstone in Figure 2-3; if it deviates from the normal trend
line, the density decreases, indicating it is surpressure. Its starting end is the top (apex) of pressure
transition zone; see point A in Figure 2-3.
Similarly, plot density values of mudstone at different well depths on the density-depth coordinates
of density vs pressure plot, shown in Figure 2-4, forming an approximate density line of mudstone of
points A, B, C and D.
Now calculate the bottom hole pressure at point C (see density vs pressure plot).AB segment is
normal density trend line of mudstone, the abnormal pressure comes across at point B, the density of
mudstone starts to decrease and the trend line offsets to the left.
Draw a vertical line from point C and intersect AB segment at point D, its well depth is
1920m, the corresponding hydrostatic pressure is 192 bar and find the value of this point on
the pressure scale, it is E and connect DE line.
Draw a parallel line DE from point C and intersect the pressure scale at point F, read the
bottom hole pressure and it is 637 bar.
Calculate the pressure gradient, namely, the theoretical value of density of mud to balance the
downhole pressure, the well depth at point C is 3840m and its hydrostatic pressure is 384 bar.
637
= 1.65
384
1.65 theoretical value of density of mud to balance the downhole pressure.
214
Hardware Manual of CMS Mud Logging Unit
215
Hardware Manual of CMS Mud Logging Unit
216