TUTORIAL DEPRESSURING Second (Compatibility Mode) PDF
TUTORIAL DEPRESSURING Second (Compatibility Mode) PDF
HYSYS
Liquid percent = 35.6 %
Wetted height = (35.6 / 100) * 11.37
Wetted Area = 96 ft2 (8.9 m2)
ACTUAL
Wetted Area = 155 ft2 ( 14.4 m2)
Checking the wetted area of this model, will result the wetted area is different with the actual
wetted area
The model volume is good enough but sometimes the wetted area is not match with the real
condition.
2 Process System
Fill Depressuring HEAT FLUX of FireAPI521
3 Process System
CHECKING HEAT FLUX Correlation
Double click the sub flow sheet of depressuring go to sub-flow sheet
environment double click Duty spreadsheet
4 Process System
CHECKING HEAT FLUX Correlation after Running With input data heat flux of
21000 btu/ft^1.64/hr
(POOL FIRE CASE).
Unit is already consistent .
6 Process System
Input C1 = 300 000 W/m2 instead of
94500 btu/ft2/hr
7 Process System
Now ,,We GET the PROBLEM.
1. HYSYS Depressuring Utility does not have Jet fire case
2. The Wetted Area not match with the real condition
8 Process System
Spreadsheet method
Cannot be changed
9 Process System
Select connections page and delete Cell D8 for tank wetted area.
Back to spreadsheet
Input = 1,
FireAPI 521
method is Applied
10 Process System
VERYFY RESULT
View Historical Data
11 Process System
SUMMARY
HYSYS also provided fire case of pool fire and doesnt have Jet fire case.
12 Process System