Pressure drop calculations

For flow between 19-757 L/min


DATA
Flow*: 37.85 L/min 37.85 L/m
Pipe length: 30.48 m
Number of 90 elbows: 2
Number of T: 1

RESULTS

Recommended pipe: 1 in*


Lineal velocity with this pipe: 1.13 m/seg
Pressure drop: 0.22 kg/cm2

* For pipes, inches are communly used in Latin America

Principles of Cleaning and Sanitation in the Food and Beverage Industry, Guillermo Etienne