MODEL PAGE MODEL PAGE

Fluid Analysis In-tank Filters


Fluid Analysis 11 OFMT Series In Tank 45
Flows to: 50 L/min (13 USgpm)
Pressures to: 7 bar (100 psi)
Elements: OFMT020 = FM020 46
Particle Counter
OFMT100 = FM100 48
Target Pro 2 Particle Counter 14
OFRT Series In Tank 51
Flows to: 1500 L/min (400 USgpm)
Pressures to: 10 bar (150 psi)
Breathers Elements: OFRT100 = FT100 52
BR110 Breather 17 OFRT250 = FT250 54
Filters out moisture and particles from incoming air OFRT630 = FT630 57
OFRT850 = FT850 60

ORFM Series In Tank 63


BR210 Breather 17 Flows to: 851 L/min (225 USgpm)
Pressures to: 10 bar (145 psi)
Filters out particles from incoming air Elements: V209...series 64

ORF 1300 Series In Tank 69


Flows to: 1300 L/min (343 USgpm)
MBR110 and MBR120 Breathers 17 Pressures to: 25 bar (360psi)
Filters out moisture and particles, ideal for mobile Elements: V209...series 70
applications
DRT DIN In Tank 72
Return Line Filters Flows to: 630 L/min (160 USgpm)
Pressures to: 10 bar (150 psi)
HV3R Series Return Line 21 Elements: VDT...series 73
Flows to: 280 L/min (75 USgpm)
Pressures to: 50 bar (725 psi) HF4RT Series In Tank 77
Elements: V3R...series 22 Flows to: 568 L/min (150 USgpm)
Pressures to: 7 bar (100 psi)
Elements: V405...series 78
HV6R Series Return Line 24
Flows to: 1,700 L/min (450 USgpm) Suction Strainers
Pressures to: 25 bar (350 psi)
Elements: V041...series 25 OSS Suction Strainers 80
Flows to: 380 L/min (100 USgpm)
HV6RD Series Duplex Return Line 27
Flows to: 1700 L/min (450 USgpm)
Pressures to: 25 bar (350 psi) OTM Tank Mounted Strainers 82
Elements: V301...series 28
Flows to: 380 L/min (100 USgpm)

OFR 30 Series In Line 31


Flows to: 114 L/min (30 USgpm) F Series Inlet Strainers 84
Pressures to: 27,6 bar (400 psi)
Elements: V602...series 32 Flows to: 380 L/min (100 USgpm)

OFR 60/120 Series In Line 34 Spin-on Filters


Flows to: 450 L/min (120 USgpm)
Pressures to: 27,6 bar (400 psi) OFRS 15 Series Spin-on 88
Elements: V405...series 35
Flows to: 60 L/min (15 USgpm)
Pressures to: 7 bar (100 psi)
DLR DIN Series Return Line 37 Elements: V019...series 89
Flows to: 400 L/min (105 USgpm)
Pressures to: 25 bar (350 psi) OFRS 25 Series Spin-on 91
Elements: VDP...series 38 Flows to: 95 L/min (25 USgpm)
Pressures to: 7 bar (100 psi)
Elements: V019...series 92
LND Series Duplex 40
Flows to: 400 L/min (105 USgpm)
Pressures to: 25 bar (360 psi) OFSS30 Series Spin-on 94
Elements: VDP...series 41 Flows to: 115 L/min (30 USgpm)
Pressures to: 10 bar (150 psi)
Elements: V176 ...series 94
2 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
MODEL PAGE MODEL PAGE

OFRP35 Series Spin-on 97 DMP DIN Series Pressure 134


Flows to: 130 L/min (35 USgpm) Flows to: 100 L/min (25 USgpm)
Pressures to: 35 bar (500 psi) Pressures to: 100 bar (1,500 psi)
Elements: V031...series 98 Elements: VDP...series 135

OFRS 60 Series Spin-on 100 DHP DIN Series Pressure 137


Flows to: 225 L/min (60 USgpm) Flows to: 400 L/min (106 USgpm)
Pressures to: 7 bar (100 psi) Pressures to: 400 bar (5,800 psi)
Elements: V021...series 101 Elements: VDP...series 141

HS22 Series Twin Spin-on 104 Off-Line Filters


Flows to: 450 L/min (120 USgpm) EPHHF Eaton Portable Handheld Filter 143
Pressures to: 14 bar (200 psi)
Elements: V021...series 105 Flows to: 15 L/min (4 USgpm)
Pressures to: 3.5 bar (50 psi)
Elements: V021...series 105
Pressure Filters

ECF Series Pressure 108 CCOFRS60 Clean Cart 144


Flows to: 19 L/min (5 USgpm) Flows to: 38 L/min (10 USgpm)
Pressures to: 207 bar (3,000 psi) Pressures to: 4 bar (65 psi)
Elements: V021...series 105

OLF15V Series Off-Line Filter 145


LV2P Series Pressure 110
Flows to: 19 L/min (5 USgpm)
Flows to: 110 L/min (29 USgpm) Pressures to: 3 bar (45 psi)
Pressures to: 100 bar (1,500 psi) Elements: V15BM...series 145
Elements: V051...series 111

LV4P Series Pressure 113 Accessories


Flows to: 110 L/min (29 USgpm)
Pressures to: 100 bar (1,500 psi) Fluid Sampling 146
Elements: V051...series 114 Differential Indicators 147
Indicator Switch Schematics 149
HF2P Series In Line and Subplate 116 Electrical Pressure Switch 151
Flows to: 90 L/min (24 USgpm) Gauge 152
Pressures to: 280 bar (4,000 psi) Mounting Bracket 152
Elements: V304...series 117
Welding Flange 153
Seal Kits 153
MF2P Series Pressure 119 Notes 154
Flows to: 113.5 L/min (30 USgpm) Notes 155
Pressures to: 275.5 bar (4,000 psi)
Elements: V051...series 120

OFPH003/005 Series Pressure 122


Flows up to: 53 L/min (14 USgpm)
Pressures to: 310 bar (4,500 psi)
Elements: OFPH31 = V0603 123
OFPH51 = V0604 123
OFPH52 = V0114 123

HF4P Series In Line and Subplate 125


Flows to: 570 L/min (150 USgpm)
Pressures to: 345 bar (5,000 psi)
Elements: V405...series 126

HF3P Series In Line 128


Flows to: 454 L/min (120 USgpm)
Pressures to: 420 bar (6,000 psi)
Elements: V602...series 129

HF3PS Series Side Mount 131


Flows to: 565 L/min (150 USgpm)
Pressures to: 310 bar (4,500 psi)
Elements: V602...series 132

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 3


Introduction to Eaton Filtration

Fluid Power is one of the most reliable and repeatable


forms of power and motion control. When problems are
encountered, 80% of the time they are related to
inadequate contamination control practices. Eaton has
more than a 75-year history of dedication to helping
engineers develop, operate and maintain reliable, high
quality power and motion control systems.

The systemic contamination Once the target has been There are four primary
control approach assures set, the next step is to sources for solid
the user of the hydraulic select and position filters contamination to enter
system a cost effective in the system so that the a hydraulic fluid.
approach to contamination target can be achieved in They are: contaminated new
control that allows the price a cost effective manner. oil, built-in contamination,
of the filters and elements After the machine is in ingressed contamination
to be quickly recovered by operation, the last and and internally-generated
the savings of improved ongoing step is to confirm contamination.
performance, increased that the target cleanliness
component life, increased oil level is being maintained.
life, increased uptime and
fewer repairs. This is most often
accomplished by sending
The goal of systemic a fluid sample to a particle
contamination control is counting laboratory that
always the same: to clean gives cleanliness code data
the fluid to the point that to established standards. If
contamination is not a factor the target is being met, the
in the failure (catastrophic, system only needs to have
intermittent, or degradation) Eaton Fluid Analysis Service PN 894276
For a hydraulic or oil filters maintained and the
of any component in the fluid retested periodically. If
lubricated machine, the
system during the desired the cleanliness target is not
development of a target
useful life of that system. being achieved, corrective
cleanliness level and the
plan to achieve it is as much The first step towards this actions need to be taken.
a part of system design as goal is the setting of a target Sometimes a change in
the selection of the pump, cleanliness level that takes maintenance practices is
valves, actuators or bearings. into account the specific needed, but at other times a
needs of the system. shift to a finer grade of filter
elements or additional filter
Vickers Systemic Sources of Contamination housings may be needed.
Approach to Eaton doc. 561, page 8
Contamination Control
Generated Ingressed from cylinder rod
Set a target Cleanliness by cylinder
Level
Select filters and filter
placements to achieve A B
target
Generated by valve
Sample fluid and confirm P T
achievement
Pressure
line filter

Transfer cart filter

Return
line
Ingressed from Generated filter
air breather Ingressed
by pump through
M reservoir M
openings Ingressed
from
Built-in debris new oil

4 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Introduction to Eaton Filtration

Contaminated New Oil be metal, silica and fibers. Ingressed Contamination Generated Contamination
Although hydraulic and With fluids from reputable Contamination from the The most dangerous
lubrication fluids are refined suppliers, sampling has immediate surroundings can contamination to a system is
and blended under relatively shown typical Cleanliness be ingressed into the fluid the contamination generated
clean conditions, the fluid Levels of 17/16/14 or dirtier. power or lubrication system. by the system itself. These
travels through many hoses Using a portable transfer cart On large installations, such as particles are work
and pipes before it is stored fitted with a high efficiency those within steelworks or hardened to a greater
in drums or in a bulk tank at filter, contamination should automotive plants, it is hardness than the surface
the users facility. At this be removed from new fluids relatively easy to know the from which they came, and
point, the fluid is no longer before the contamination environmental conditions, are very aggressive in
clean as the fluid lines it has enters and damages the though they vary considerably. causing further wear in the
traveled through have components in the system. For example, a coke oven system. In a system running
contributed metal and rubber system operates in conditions on properly cleaned fluid very
particles, and the drums Built-in Contamination very different from a similar few particles are generated,
have added flakes of metal New machinery always system in a cold mill. For although all components
or scale. Storage tanks are a contains a certain amount of mobile equipment, there is a (especially pumps) create a
real problem because water built-in contamination. Care very wide variation in small amount of particles
condenses in them causing in system assembly and in environmental conditions by during routine operation. In a
rust particles. Contamination new component flushing application, location and even system where these particles
from the atmosphere can reduces this but never by weather conditions (i.e. are not quickly captured the
eliminates it. Typical built-in high winds). elevated contamination levels
The key is to severely limit will cause the number of
the access that environmental additional generated particles
contamination has to enter to increase at a highly
the hydraulic or lubrication accelerated rate! The best
system. There are four major way to prevent
ways dirt can enter a system: contamination generation
reservoir vent ports (breathers), within a system is to start
power unit or system access with a clean (fully flushed)
plates, components left open system and keep the system
during maintenance and fluid clean.
cylinder seals.

Eaton Clean Cart

also find its way into the Eaton H20 Gate Reservoir Breather BR110
tank unless satisfactory air
breathers are fitted. contaminants are burrs,
If the fluid is stored under chips, flash, dirt, dust, fiber,
reasonable conditions, the sand, moisture, pipe sealant,
principal contaminants on weld splatter, paint and
delivery to the machine will flushing solution.

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 5


Introduction to Eaton Filtration

Filter Element Initial Beta ratios and dirt capacity. Eaton Media Construction
Efficiency The most important
The international standard for information needed by a
rating the efficiency of a designer or user of a
hydraulic or lubrication filter hydraulic system is the
is the Multipass Filter system cleanliness they can
Performance Beta Test (ISO expect when that filter and
16889). The results of this media are properly installed
test are reported as a ratio of in the system.
number of particles greater Each grade of Eaton high
than a designated size efficiency filter media
upstream of the test filter construction is thoroughly
compared with the number multipass tested and then
of same size particles rated with the system
downstream of the test filter. cleanliness level expected to
These results are then be achieved with the use of
expressed as a Beta ratio. that product. The
Most Eaton filters are assumptions behind these may fail to answer the and gives the filter medium
rated at Beta x(c)=1000. See cleanliness ratings are: 1) the question of how an aged the support it needs to keep
individual filter Features and filter sees full system flow, element will perform during from failing due to fatigue.
Benefits for more detail. 2) the filter is the primary the latter part of its service The downstream wire mesh
filter in the system, and 3) life. also serves as a last chance
BETA RATIOS AND air breathers along with protection in case of
CORRESPONDING EFFICIENCIES The best way to deal with
recognized maintenance unexpectedly severe stress
Beta Ratios Efficiency this issue is to look at the
practices will limit dirt that causes element media
construction and feel the
1 0% ingression from the rupture.
element pleats. Are the
2 50.00% atmosphere.
pleats well supported? Do
5 80.00% A major problem in correlating they flex under hand Filter Condition Indicators
10 90.00% multipass test claims to real pressure? Any element that After the filters are placed
20 95.00% world fluid cleanliness levels fails these simple tests will within the system, the next
75 98.00% is that real systems operation fail to maintain efficiency and consideration is how the
100 99.00%
greatly stresses the element. integrity, and will not user is going to know when
In active systems, flow rate maintain the targeted to change the element. The
200 99.50% changes (often several times cleanliness level. answer recommended in
1000 99.90% a minute), pressure pulses DIN 24550 standard is to
5000 99.98% Additionally, look at the pack
(hundreds a minute), have all filters fitted with a
construction. Steel wire
Beta ratios and dirt capacity are only decompression shock differential pressure indicator
mesh is very important in
a guide to system cleanliness needs waves, cold starts and other that gives an easy-to-read
ref. Eaton doc. 561, page 19 element construction. Wire
variables all work to degrade indication that the element
keeps the pleats from flexing
a filters performance. In needs to be changed. Eaton
Multipass testing has greatly multipass testing the element
aided engineers in the is subject to one gradual rise LIMITS ON CORRELATION BETWEEN BETA AND SYSTEM
development of better and in differential pressure as the CLEANLINESS AND DIRT CAPACITY AND SERVICE LIFE
more efficient filter element loads! Laboratory Procedure Real World
elements, and it has helped Flow fatigue test protocol Pressure Rise One gradual rise Thousands of changes
the design engineer who (ISO 3724) leaves many Fatigue Cycles One Millions
needed to specify a filter important questions
elements performance. But, Element Aging Minutes Months
unanswered. Again the Element Life One hour 800+ hours
theres little correlation element is tested in laboratory
between multipass Contaminant AC fine test dust Debris, water, gas
conditions that cannot
efficiencies and system duplicate the interaction of Challenge Rate Constant Always changing
cleanliness needs. In the the many forces working to Fluid Used MIL 5606 Wide variety
final performance analysis, stress and degrade the Temperature 100F (38C) -20F to 200F (-7 to 93C)
the goal is properly cleaned element. This laboratory test Flow Steady Thousands of changes
fluid and not just very high

6 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Introduction to Eaton Filtration

indicators are designed to In poorly supported elements, changes in flow and pressure drop cause the
indicate at a pressure drop sides of element corrugations to flex and the root to stretch, giving rise to fatigue
20% below the bypass stresses. Dirt capacity is also lost as areas of the medium have no flow.
setting which equates to Eaton doc. 561, page 21
95% of the elements
service life. This indication
before bypass feature was No flow Flow directions
incorporated to allow safe
operation of the machine Deflection under Filter medium
until the next shift change or high flow
convenient maintenance
opportunity.

Element Service Life


High stress under Flow fatigue failure is
As in any aspect of machine high flow conditions commonly at root of pleat.
design or maintenance, cost causes pleat to deform.
of installation and operation
are very important concerns. always use genuine Eaton media structure only, which
For filters, the length of elements because of their can give increased dirt
time an element lasts in consistent performance capacity under laboratory
service and the initial cost of and superior strength under conditions, but no increase
that element, combine to stress. in service life is experienced
determine the economics in real systems.
The third issue in long
of using that product.
element service life is the An often overlooked aspect
The most important aspect dirt capacity of the of dirt capacity and service
of gaining long element element. This value is life is the effect of element
service life is to minimize the calculated as part of the area. When comparing an
ingression! Reservoirs need multipass efficiency test. element of x area with an
to be fitted with vent filters Because of the many element of 2x area, one
(=3m) that remove the dirt differences between the test would expect twice the life
before it enters the system. conditions and real system for the larger element. But,
Access port and doors need operation, different dirt in real systems, the life
to be kept sealed so that dirt capacity values do not extension is most often
cannot be drawn into the correlate well to changes in between 2.5 and 3.5 times
system. Cylinder rods that element service life. Dirt as long. This is because the
extend into contamination capacity can only be used to reduced flow density through
laden environments should compare elements under a unit area of media allows for
be shielded to minimize the very specific laboratory more effective contaminant
dirt being drawn into the situations, and as a result capture. Larger elements are
system. published dirt capacity values the most cost effective
The second important aspect should be used as general approach to contamination
to long element service life information rather than control from the perspective
is to keep the cleanliness specific comparable data. of operating costs.
level of the fluid at or below Eaton elements are designed
target. Periods of machine to give long life and reliable
operation with dirty fluid service in hydraulic or
cause accelerated internal lubrication applications.
wear that loads a filter This is achieved with our
element. (Its important the multi-layer construction.
debris is caught as it saves Each layer provides
the system, but it does cost additional strength or
the element part of its capacity leading to overall
service life.) Always change superior performance. Some
an element on indication and elements focus heavily on

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 7


Guide for Selecting Filters

Target Cleanlines that maintenance of the Housing for longer element life.
Using the Vickers Target system will be consistent The selected housing should Some systems require
Cleanliness Worksheet with current technology. be rated within the required filtration with no bypass,
(#578), it is easy to If in operation the system is flow and pressures of the such as servo applications.
determine the target ISO running dirtier than expected, application. Vickers H-Pak media is
Cleanliness Level for a corrective actions should be Important: If the system recommended for non-
system. This target is based initiated. Suggested corrective fluids specific gravity (SG) is bypass systems.
on the applications actions are: greater than 0.9 (for
components and system Check the indicator to example, water glycol), the Indicator
dynamics. see if the filters are on housing pressure drop (P) To meet ANSI Standard
by-pass. should be corrected for 12.2.5, filter assemblies
Placement and Media actual application. should have a device to
Check the sources of
Use the chart below to help ingression and correct indicate when the filter
select the appropriate filter problems. Specific Gravity requires servicing. Per ANSI
placement and grade of Corrections for Pressure Standard 12.2.6, the
media to acheive the target Check that the filters are Drops indicator should trip at
cleanliness level. For more positioned properly to see approximately 80% of the
maximum fluid flow. The filter housing flow
detail, consult the Eaton curves in this catalog can be bypass pressure setting. If
Guide to Systemic Consider using a finer adjusted using the following using a non-bypass housing,
Contaminaton Control, Pak grade equation: an indicator selling of
your Vickers representative, approximately 100 psid is
Add additional filters to Adjusted PHousing =
or the ANSI System recommended. Differential
the system. PCurve x Actual SG 0.9
Standards for Stationary pressure indicators are rated
Industrial Machinery. 6,000 psi working, 3,500 psi
Note: All systems need a Bypass Valve fatigue.
Filter Placement sealed reservoir with vent Bypass valve selection is
The chart below helps port filtration. based upon system
engineers select the grade requirements. According to
of Vickers media and the CAUTION ANSI Standard 12.2.6, filter
filter placement(s) that will assemblies whose elements
Before servicing the
acheive the required target cannot withstand full system
element, the bleed
cleanliness. It assumes the differential pressure without
plug in filter housing
system will experience damage should be equipped
must be loosened to relieve
average ingression and with bypass valves.
pressure. This will minimize
Generally, a higher bypass
fluid overflow.
pressure setting will allow

RECOMMENDED RECOMMENDED RECOMMENDED


FILTER PLACEMENT FILTER PLACEMENT FILTER PLACEMENT
TARGET FOR HIGH FOR SYSTEMS WITH FOR HIGH
CLEANLINESS INGRESSION VARIABLE VOLUME INGRESSION
SYSTEMS WITH PUMPS. SYSTEMS WITH
FIXED VOLUME VARIABLE VOLUME
PUMPS. PUMPS.

Full flow pressure Full flow pressure Pressure line/ Pressure line plus Recirculating loop at Recirculating loop at
line or return line line or return line recirculating loop at return line plus 20% of system volume 10% of system volume
20% of system volume recirculating loop per minute per minute
per minute
14/12/10 - 03 03 03 - -
15/13/11 - 03 03 05 - -
16/14/12 03 05 05 05 or 10 03 03
17/15/13 03 05 05 05 or 10 03 03
18/16/14 05 10 05 or 10 10 05 03
16/14/10 05 or 10 10 10 10 05 or 10 05

8 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Guide for Selecting Filters

Surge Control H-Pak Construction L-Pak Construction


Surge Control is used on For systems where a bypass The L-Pak is specially
systems where spikes and valve is undesirable, such as designed for lubrication
surges in the hydraulic servo systems, the H-Pak applications. Using the same
system could prematurely media provides high collapse five layer construction as the
trip the indicator. Surge rated housing pressures. C-Pak, the L-Pak also has a
controls slow the indicator H-Pak media construction deep pleat construction to
response. If the indicator utilizes 304 stainless steel maximize element life in
encounters a continuous inner and outer mesh support steady flow, low pulsation
high differential pressure, it along with heavier core systems.
will trip at the rated setting. tubes and media support to
protect the system.
Element
C-Pak Construction
The Vickers element media
grade should be selected C-Pak media uses five
to acheive the Target layer construction. C-Pak
Cleanliness Level. The incorporates epoxy coated
Vickers media construction carbon steel as the two
should be chosen based outer face layers to retain
upon system requirements the inner media pak layers.
such as flow characterstics,
R-Pak Construction
pressure surges and specific
application conditions. The R-Pak spin-on filter
elements are designed for
Important: If the system low clean pressure drop
fluids specific gravity (SG) and high efficiency. R-Pak
is greater than 0.9 (for incorporates a five layer
example, water glycol), the media construction with
element pressure drop outer layers of epoxy coated
(P) should be corrected. carbon steel wire to retain
the inner media pak layers.

Viscosity Corrections for Pressure Drops


The element flow curves can be adjusted using the following equations:
Adjusted Clean PElement =
Actual viscosity in cP 29 x PCurve
Actual viscosity in cSt/32 x Actual SG 0.9 x PCurve
Actual viscosity in SUS/150 x Actual SG 0.9 x PCurve
A good rule of thumb. To ensure satisfactory element life, the clean element pressure
drop should generally be less than or equal to 40 percent of the indicators rated differential
pressure:
PElement = 0.4 x PIndicator
The best way to extend element service life is to minimize ingression (vents, seals, cylinder
rods) and maintain system cleanliness at or below the Target Cleanliness Level.

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 9


Eaton Fluid Power Training
Learn from the Hydraulics Experts!

Knowledge is power. And


nowhere can your team
strengthen its knowledge
more effectively than
through lessons learned in
courses offered by Eaton
Fluid Power Training.
Participants in Eaton Fluid
Power Training courses can
save their company
significant money by
reducing unplanned
downtime and maximizing
the effectiveness of planned
downtime. Each year more
than 2,500 people attend
training courses at Eaton
training facilities in Eden
Prairie, Minnesota, and
Maumee, Ohio.
Systemic Contamination
Control
Among Eaton Fluid Power
Trainings most beneficial
courses is Systemic
Contamination Control. This
two-day course covers the
fundamentals of systemic
contamination control, Participants in Eatons Systemic Contamination Control course learn how to determine the cleanliness of a hydraulic system using the Eaton
including why contaminated Target-Pro portable particle counter.
oil can significantly reduce
the service life of Fluid characteristics Maintenance, sales and
components in a hydraulic Purposes and properties design personnel will benefit
system and how keeping of hydraulic fluid, types from the course that is
systems clean can result in of fluid and fluid failures offered at Eaton Fluid Power
significant savings by Training facilities, as well
reducing downtime due to Contamination control
Critical clearances in as at Eaton distributor and
premature component customer locations. For a
failures. Also covered are components, fluid
testing methods, filter complete course description,
contamination control visit
requirements of hydraulic ratings, beta ratios,
media construction and www.eatonhydraulics.com
systems, enabling /training.
participants to properly breakdown, Delta P
design, maintain and indicators, filter selection To contract the services of
purchase hydraulic systems and fluid sampling Eaton Fluid Power Training,
and components. The methods call 1-800-413-8809.
course includes hands-on Particle count
sampling and draw-down methodology
testing of fluid samples. Eaton Target-Pro portable
Specific topics covered particle counter and Eaton
in Eatons Systemic Fluid Analysis Kits, which
Contamination Control rate a systems cleanliness
course include: through detailed laboratory
testing

10 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Fluid Analysis
Eaton Fluid Analysis Service Critical Analysis Clear Benefits
Eaton hydraulic components have a global reputation Fluid is the lifeblood of every We offer testing designed to
for quality, reliability and performance. That reputation hydraulic power system. To tell you the most about your
keep yours running hydraulic fluid. We use
is built on a tradition of customer service and we
efficiently and effectively, sophisticated computer
stand behind every one of our products. you need to know whats in programs and laboratory
Our Fluid Analysis Service follows that same tradition. it. What you dont know can diagnostic equipment such
hurt you. as an Energy Dispersive
We provide our customers with comprehensive fluid
The Eaton Fluid Analysis X-ray Fluorescence and an
testing and diagnostic services, with detailed reports inductively coupled plasma
that are easy to understand. Service analyzes hydraulic
fluid in much the same way spectrophotometer.
To find out how the Eaton Fluid a medical lab tests a blood After we use this advanced
Analysis Service can help your sample. Just as a blood test equipment to provide the
operation, read on. helps a doctor diagnose most detailed possible
health problems, a sample of analysis of your hydraulic
Then call us to hydraulic fluid can help fluid, we create reports that
get started. us pinpoint sources of are always easy to read and
contamination and determine understand. By taking the
whether or not your system mystery out of fluid analysis,
uses adequate filtration. we provide a service that
We can help you reduce clearly explains the benefits
catastrophic equipment of clean fluid.
failures, maintain optimum
A Name You Trust
component performance,
Only one fluid analysis lab lets you put years of Eaton and identify any substandard
experience to work for you. So when the health of maintenance practices. Your
your hydraulic system is at stake, choose a partner bottom-line benefit is
with more than 75 years of experience. Contact your increased productivity.
Eaton representative for more information on our Fluid
Analysis Service.

Comprehensive Testing Viscosity (ASTM D445): and degrades equipment if any, are needed. The lab
We use this test to determine performance. is also capable of testing to
The Eaton Fluid Analysis the viscosity of your oil. the new ISO 4406(1999)
Service is certified to ISO Drawdown Particle
Without proper hydraulic fluid Isolation: Using this test, standard (4, 6,14).
12025 and offers a full range viscosity, your equipment will
of tests specifically designed we determine the insoluble Spectrometric Analysis
suffer. Incorrect viscosity contaminates in hydraulic (ASTM D 5185): This shows
for the analysis of hydraulic leads to fluid breakdown,
and lubrication system fluid. fluids, both insoluble us the concentration of oil-
inefficient equipment particles and gel-like matter, soluble elements and
Our laboratory equipment operation, premature system
and test procedures provide organics and inorganics. indicates the additives and
failure and damage to other Used in conjunction with trace metal content in the
an exact analysis of your components.
hydraulic or oil lubricated photomicrography, the fluids. We use this technique
system, and our drawdown drawdown patch helps us to evaluate the condition
particle isolation procedure identify the source and type of the additives in a fluid
ensures accurate results. of fluid contaminants. rather than its particulate
Automatic Particle Count contamination. Used in
Our testing procedures (ISO 11500): We use a high- conjunction with automatic
can include: intensity laser light source and particle counting, it helps us
a photo sensor to count the accurately assess the
Photomicrography: We cleanliness level of the fluid.
scan and photograph a filter number and size of particles
patch using an optical in the fluid sample and then Energy Dispersive X-ray
microscope to find particle define contaminants Fluorescence (ASTM E
size and type. The scanning according to size distribution 1508): We perform Energy
Water (ASTM E203): We and quantities. Automatic Dispersive X-ray Fluorescence
process verifies the determine the water content
automatic particle count to particle counting is quick, (XRF) analysis on samples
in hydraulic fluid, which helps repeatable and accurate. It with extremely high
identify samples needing us predict quality and
special preparation. This provides reliable information concentrations of particulate
performance characteristics we can use to check against contamination. By isolating
provides confirmation of for the fluid and system
automatic counter results, ISO Standard 4406, which chemical elements, we
components. Excess water defines the relationship pinpoint contaminant types so
and helps us see what reduces the viscosity of
contaminants are in the fluid. between particle counts and we can establish their origins,
hydraulic fluid, which hydraulic fluid cleanliness. and so you can take corrective
increases the likelihood of This lets us determine exactly action.
adverse chemical reactions what corrective actions,

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 11


Fluid Analysis
Easy-to-Read Reports 1. Results Target: A results Fluid Test Results
Fluid Results
target compares your
We present your fluid test actual fluid cleanliness 2 5
results in a format that is results and your ideal
easy to understand. Results cleanliness level. If you
typically include these items: dont have a target level yet,
we can use your sample to
help you determine what
it should be. WATER 15

2. Trend Information: We
evaluate data from your VISCOSITY
previous two samples On-target Re-sample
along with the results of Marginal Immediate action
your current sample. This
provides a trend analysis
of critical measurements, TEST 1 TEST 2 TEST 3
and shows changes in the Time Present Previous #1 Previous #2
fluid over time. Viscosity 45.0 (210) 45.5 (212) 45.8 (213)
@ 100F cSt (SUS)
pH (ASTM E 70)
represents the strength of Water 0.03% 0.03% 0.03%
% Weight
Vacuum Pump PN 894279 acidity in hydraulic fluid,
and is usually measured pH 9.4 9.5 9.6
Note: pH is for water containing fluids only.
for water-containing
hydraulic fluids TAN mg KOH/gm 2.1 2.0 2.1
Note: TAN is for synthetic fluids only.
(water/glycols, invert
emulsions). Typical values
are 8.510.5. Particle Count Summary
Total Acid Number, or TEST 1 TEST 2 TEST 3
Time Present Previous #1 Previous #2
TAN (ASTM D 974), is the
amount of acid and acid- >2 65,120 4,100 418
acting material constituents >5 12,220 1,250 88
in hydraulic fluid. An >10 5,800 700 39
increase in TAN indicates >15 900 250 22
oxidation or acid >25 125 60 4
contamination. Some >50 12.0 5.0 1.0
hydraulic fluids exhibit
higher acid numbers than Cleanliness 23/21/17 19/17/15 16/14/12
Code
others. Typical values are
0.13.0.

KIT FEATURES

Photo Energy
Automatic Microscopy Dispersive Spectrographic
Particle Water Viscosity Drawdown XRF ASTM Analysis
Kit Count ASTM TAN/PH ASTM Particle E1508 ASTM
Part # ISO 11500 E203 (if applicable) D445 Isolation (if applicable) D5185
894276
894277
Each kit includes:
Super clean sample bottle
Packaging for sending sample
Numbered test sample data form
Fluid analysis service

Also available is PN 894279, Vacuum Pump for extracting oil sample, and PN 932339, Ultra Clean Bottle.

Items not in bold are non-standard and may have a longer lead time
12 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Cleanliness Code Graph
Fluid Analysis Range Code
300,000
25 200,000
100,000 150,000
24 100.000
80,000
3. Cleanliness Code Graph: 23 50,000
This graph uses the ISO 40,000 40,000
22 30,000
4406 standard for 20,000 20,000
measuring and depicting 21 15,000
10,000 10,000
the amount and size of 20
5,000 5,000
particles per milliliter in 4,000
hydraulic fluid, shown in a 19 3,000
2,500 2,000
log-log2 graph that charts 18 1,500
the amount of particles 1,000 1,000
17

Number of particles greater than size per mililiter


greater than certain micron 500 500
sizes per milliliter of fluid. 16 400
250 300
Recommendations: This 15 200
100 150
section of the report 14 100
provides you with valuable 80 50
information on the 13 40
40 30
cleanliness of your 12 20
20
hydraulic system, as well 11
10
as tips on maintaining or 10 10
improving its current 10
5 5
condition. 9 4
3
2.5 2
8 1.5
1.5 1.0
7
1 .5
6 .4
.5 .3
5 .2
.15 .01
4 .1
.08
3
.04
2
.02
1 .01
1 4 6 10 14 20 25 30 35 40 45 50
20/14/12 Particle size in micrometers
Cleanliness code

Sample XRF Analysis 100


Results
When a fluid sample shows 90
high particulate 80
contamination, we use
Energy Dispersive X-ray 70
Fluorescence (XRF) analysis 60
to isolate and identify
Percent

chemical elements. The 50 47.8%


results are shown in a graph
40
like this.
30 24.7%
20
13.9%
10 9.0%
4.6%
0
Ca P S Fe Zn
Element

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 13


Particle Counter
Target Pro 2
Lab Quality in the Field
Eatons Target-Pro 2 Portable Particle Counter gives you The Target-Pro 2 (PN 5002405) includes two rolls of thermal
laboratory quality particle count results in the field. It paper, one waste bottle, one waste hose, one pressure hose,
combines state-of-the-art laser particle counting technology one power adapter, one RS-232 serial cable, and Target-Pro 2
with a user-friendly interface and compact size. It allows you software for Windows. A Bottle Sampler (PN 5002406) is
to monitor the fluid cleanliness of hydraulic and lubrication available as an option.
systems and take action if necessary.
The Eaton Method of
Systemic Contamination
Control:
1. Set: Set a Target
Cleanliness Level for
the system.
2. Select: Achieve the Target
Cleanliness by appropriate
filter selection and
placement.
3. Sample: Maintain the
Target Cleanliness by
monitoring the system and
taking action as necessary.

The Target-Pro 2 measures


and quantifies solid
contaminants in hydraulic,
lubrication and transmission
applications. It is designed to
provide laboratory accuracy
at the job site, whether your
application is mobile or
stationary.

14 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Particle Counter
Target Pro 2

Umbilical LCD Screen Printer with


Cable Paper Cutter
Bottle
Sampler Keyboard
(optional)
Sampling
Pressure Cap
Chamber

Out
to Waste
Sample Bottle Target-Pro 2 software for
Bottle Windows, included with the
analyzer, allows you to
download test results and
Quick Coupling Connector analyze cleanliness trends
over time.
Vacuum
Cap

TECHNICAL INFORMATION

Technology Automatic Optical Particle Analyzer Operation Max. system working pressure,
Laser Package Twin Laser and Twin Optical 400 bar; Min. working pressure, 2 bar
Diode Detectors Viscosity Range to 400 centistokes
LCD display (backlit) Operating Temperature +5 to +80C
Sensitivity >4, 6, 14, 21, 25, 38, 50, 68 Fluid Compatibility Mineral oil and petroleum based fluids
m(c), Micron range to revised (consult Eaton for other fluids)
ISO 4406 Standard
Typical Test Time Result in <2.5 mins. (normal test)
Accuracy/Repeatability Better than 3% typical
Power Internal rechargeable battery
Calibration Each unit is individually calibrated with (AC charger) or external 12/24 volt
ISO Medium Test Dust (MTD) to DC power supply
ISO 11171:1999 on equipment
Data Storage 600 tests
certified by I.F.T.S.
Computer Interface RS-232 (serial) communication port
Analysis Range ISO 8 to ISO 24 to ISO 4406
(NAS 1638-2 to 12) Hose Connections minimess fittings microbore hose, 1.5 m
waste fluid hose
Report/Print Format ISO and NAS codes, with individual
particle counts as a built-in option Dimensions Height 210mm; Depth 260mm;
Width 430mm; Weight 7.6 kg
Printer Fixed head thermal printer
(384 dots per line) 5002405 - Particle Counter
5002406 - Bottle Sampling
Target-Pro 2 Sample Volume 15 ml. (normal), 30 ml. (dynamic)
24 ml. (bottle sampler) 15 ml.
(continuous), 8ml. (short)

Note:
The TargetPro should only be operated on petroleum based
fluids, synthetic or biodegradable fluids. For phosphate
esters, Skydrol, crankcase fluids with high soot content,
or water glycol, please consult Eaton.

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 15


Breathers

Hydraulic reservoirs breathe air in and out as the oil level rises and falls.
This circulating air contains particles and moisture that can cause
corrosion, increase equipment wear and reduce fluid performance. In
typical systems, the internal hydraulic fluid is warmer than the
external environment. This difference in temperatures causes
water vapor to form. Breathers protect your hydraulic
system by filtering out damaging moisture and particles.
More than 25% of the samples sent to the Eaton Fluid
Analysis Laboratory for analysis have significant water
contamination. In an operating system, the H20-gate
Vent Breather creates a moisture barrier when there
is a 5F (2C) difference between reservoir and
ambient temperature and when there is a 10%
per minute exchange of air volume above the
fluid. The Mobile-gate breather is smaller in
size but is also 1/4 the size and 1/2 the capacity
of the H20-gate. These temperature and air flow
conditions are present in most hydraulic systems
which employ a cylinder.

Part Numbers:
NPT Mobile-gate MBR110
Flange Mobile-gate MBR120
H20-gate BR110
Dirt-gate BR210

Performs as a gate Works even when the Reduces humidity inside


During the inhalation cycle, system is shut down. reservoir.
the proprietary media blocks The H20-gate and Mobile- The H20-gate and Mobile-
the water vapor from entering gate Vent Breather retard the gate Vent Breathers lower
the reservoir. During the vapor equilibrium process and stabilize the relative
exhalation cycle, the media and work to prevent humidity of air inside the
allows the moisture in the condensation even after the reservoir, leading to a lower
reservoir air to exit. The system is shut and cooled dewpoint (Tdewpoint <
moisture is carried off the down, such as overnight. As Tambient = NO
media by the exiting air, this chart illustrates, the CONDENSATION) at a rate
restoring the medias water dewpoint is slow to climb, and amount that will be
barrier capacity and the even after the system dependent upon several
moisture barrier mechanism is temperature has dropped to conditions: the ambient
not affected by the amount of the ambient temperature. conditions, the internal
exposure to moisture. The Once the system has reservoir heat, amount and
reservoir air is maintained at a reached ambient frequency of reservoir air
low relative humidity and temperature, condensation flow through the vent and
more importantly, at a lower does not occur. the temperature of the
dew point temperature than reservoir surfaces.
the ambient temperature.
BREATHER FEATURES

H2O-gate Dirt-gate Mobile-gate


Visual Indicator
Particle Control
Water/Moisture Control
Corrosion Resistant Housing
Flow Rate 708 L/min 708 L/min 473 L/min
(187 USgpm) (187 USgpm) (125 USgpm)

16 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Breathers

H2O-gate Reservoir Breather

Features/Benefits: Media contains oil Part Numbers:


Visual Mechanical attractant layer to collect
and return oil splashes. H20-gate BR110
Indicator: Actuates when
Bayonet Adapter 924710
particles have blocked the Easy Installation:
media, before the pump Lightweight design can Screw-in Adapter P-077002
cavitates. be hand tightened onto
Proprietary Media: adapter.
Reduces dew point Durable Plastic Housing:
temperature to prevent Protects the media from
condensation and is external splashing.
99.7% efficient in blocking Superior breather filters
particles 3 and larger. both moisture and
Reversible Flow Through particles from air.
Media: Allows for Effective up to 121C
moisture to exit the (250F)
reservoir.
Rated up to 25 SCFM

Dirt-gate Reservoir Breather


Features/Benefits: Part Numbers:
Visual Mechanical Durable Plastic Housing: Dirt-gate BR210
Indicator: Actuates when Protects the media from
particles have blocked the external splashing. Bayonet Adapter 924710
media, before the pump Screw-in Adapter P-077002
High Efficiency:
cavitates. (99% at 2 microns)
Easy Installation: Very Low Pressure Drop Note:
Lightweight design can
be hand tightened onto Filters out particles This breather does not filter
adapter. moisture from air.
Effective up to 121C
(250F)
Rated up to 25 SCFM

Mobile-gate Filler Breather Assemblies

Features/Benefits: Part Number


Proprietary Media: Reversible Flow Through MBR110 5002486
Reduces dew point Media: Allows for MBR120 5002487
temperature to prevent moisture to exit the
condensation and is reservoir.
99.7% efficient in Easy Installation:
blocking particles 10 Lightweight design can be
and larger. hand tightened.
Water Barrier: Rugged metal housing is
Regenerates its water long lasting and ideal for
shedding capacity with mobile applications.
each cycle.
Rated to 16.7 SCFM
MBR120
MBR110

Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 17
Breathers

H2O-gate Specifications Dirt-gate Specifications


19 19
133,4 (.75) 133,4
(5.25) (.75)
(5.25)

105
(4.13)
184,2 12
(7.25) (.47)

12
(.47)
1.5 UN Straight Thread

1.5 UN Straight Thread

H2O-gate Pressure Drop Dirt-gate Pressure Drop


Fluid Displacement L/min (USgal) Fluid Displacement L/min (USgal)
283 850 1416 1982 2406 283 850 1416 1982 2406
(75) (225) (375) (525) (675) .0075 (75) (225) (375) (524) (636) .0075
3.0 3.0 (.108)
(.108)
2.7 2.7
Inches of water

2.2 2.2
Inches of water

.005 2.0 .005


2.0 (.073)

bar (psi)
(.073)
bar (psi)

1.7 1.7
1.2 1.2
1.0 .0025 1.0 .0025
(.036) (.036)
0.7 0.7
0.2 0.2

0 10 20 30 40 50 60 70 80 90 0 10 20 30 40 50 60 70 80 90
Air Flow, SCFM Air Flow, SCFM

Mobile-gate Specifications
PART NUMBER FLOW DIMENSIONS (in)

USgpm L/min D1 D2 D3 D4 H1 H2 T1
MBR110 125 475 3.08 - - 2.33 0.63 NPT 3/4
MBR120 125 475 3.08 1.88 - 2.50 3.50 -
MBR120 FLANGE - - - - 0.25 2.81 - - -

D1 D1

H1 H1 D3

D4
H2
H2 T1

D2
18 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Breathers
Adapters

Installation Dimensions

Threaded Pipe Adaptor Bayonet Adaptor


82,6
(3.25)
21,7
(.853) 25,4
19,1 (1.00)
(.750) Vent Filter

O-ring 11/4 NPT


Bayonet Adaptor
11/2-16 UN
Standard Mounting
Flange of a reservoir
filler/breather
assembly
MODELS AND PART NUMBERS
Part Number Description Vent Filters Applicable
924710 Bayonet, no check BR110, BR210
P-077002 Threaded pipe BR110, BR210

All Eaton Vent Filters are easily applied


to reservoirs via Spin-On adaptors.

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 19


Return Line Filters

General Data
Return line filters usually have spin-on type elements, Return line filters may also be equipped with fluid
cartridge elements in an in-line mounted housing, or sampling devices to monitor the fluid cleanliness
cartridge elements within a housing that is mounted level. Secondary ports may also be incorporated to
directly within the reservoir itself (sometimes referred add make-up fluid and ensure that the fluid is
to as an in-tank filter). transferred through a filter before entering the system.

Return line filters are:


An integral part of an A crucial component
effective contamination when cylinders are
control solution. present in the system.
Ideal for systems where Cylinders potentially
the pump is the sensitive contribute a large amount
component. of contamination
ingression and return line
An economic means filters are ideal for this
of achieving the target type of control solution.
cleanliness level.
Sometimes the only filters
Often placed before the necessary (combined with
fluid enters the reservoir a breather) when seeing
in order to prevent debris the entire system flow on
and particles from a continuous basis.
recirculating through the
system. Only a part of an effective
contamination control
solution when the
system employs variable
displacement pumps.
Filters in systems like this
may be supplemented by
pressure and/or off-line
filters.

Applications
Stroke boom delimbers
Drilling platforms
Die cast machines/
injection molding
Large machine tools

Items not in bold are non-standard and may have a longer lead time
20 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Return Line Flows to 280 L/min (75 USgpm)
Pressures to 50 bar (725 psi)
Filters
HV3R Series

Features and Benefits DESIGN SPECIFICATIONS

Beta Ratio: x(c) = 1000 Rated flow: Length 1 160 L/min (42 USgpm)
to ISO 16889 Length 2 240 L/min (63 USgpm)
Length 4 280 L/min (74 USgpm)
Designed to comply with Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids
ANSI specifications and Optional seals available for phosphate esters.
ISO cleanliness standards Temp range: -30C to 121C (-22F to 250F)
Visual and electrical Pressure rating: Operating 50 bar (725 psi)
indicators with lamp Fatigue 50 bar (725 psi)
options for system design Material: Head Aluminum
flexibility Bowl Carbon Steel
Fully serviceable without Collar Carbon Steel
tools Dry weight: Length 1 2,3 kg (5.1 lbs)
Zero leak by-pass valve (Approximate) Length 2 2,5 kg (5.5 lbs)
Length 4 3,4 kg (7.5 lbs)
construction
Wide range of element
lengths for maximum
design flexibility
High efficiency
replacement elements in
standard configurations
(C-Pak) to meet Target
Cleanliness Levels HV3R * ** * ** * * * **
High collapse elements
available for non-bypass 1 2 3 4 5 6 7 8 9
applications
HV3R Series 1 Filter Series - HV3R QH - Electrical 1 bar (15 psi) UH - Electrical 4.9 bar (70 psi)
Filter and Element Hirschmann Hirschmann
Model Code 2 Element Collapse Rating
LN - Visual (30 psi)
No Connector 6 Seal Material
1 - 17 bar (250 psi) Low Collapse RB - Electrical 2 bar (30 psi) B - Buna-N
Sample model code: 4 - 207 bar (3000 psi) High Brad Harrison V - Viton-A
Collapse RJ - Electrical 2 bar (30 psi) Viton is a registered trademark of E.I. DuPont
HV3R1SC4RLB2C05
3
Hirschmann w 24 volt
Port Options light 7 Assembly Length
BC - G 1-1/4 to ISO 228 RK - Electrical 2 bar (30 psi) mm (inch)
SC - 1.625 - 12UN SAE-20 str. Hirschmann w 115 volt 1 - 207 (8.15)
Thd. (1-1/4" tube) light 2 - 266 (10.47)
RL - Electrical 2 bar (30 psi) 4 - 447 (17.6)
4 Valve Options Hirschmann w 230 volt
1- Non-Bypass light 8 Element Construction
3- Bypass set at 1.7 bar (25 psi) RH - Electrical 2 bar (30 psi) C - 17 bar (250 psi) Low Collapse
4- Bypass set at 3 bar (43 psi) Hirschmann H - 207 bar (3000 psi) High
6- Bypass set at 6 bar (87 psi) AN - Visual (70 psi) Collapse
No Connector X - no element
5 Indicator Options UB - Electrical 4.9 bar (70 psi)
JN - No Indicator (plug), Brad Harrison 9 Fluid Cleanliness Rating
No Connector UJ - Electrical 4.9 bar (70 psi) Target fluid
QB - Electrical 1 bar (15 psi) Hirschmann w 24 volt Code cleanliness level
Brad Harrison light *03 16/14/12 or better
QJ - Electrical 1 bar (15 psi) UK - Electrical 4.9 bar (70 psi) *05 18/16/14 or better
Hirschmann w 24V light Hirschmann w 115 volt
light *10 20/18/15 or better
QK - Electrical 1 bar (15 psi)
Hirschmann w 115V light UL - Electrical 4.9 bar (70 psi) *20 22/19/16 or better
QL - Electrical 1 bar (15 psi) Hirshman w 230 volt light XX no element
Hirschmann w 230V light
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 21
Return Line Flows to 280 L/min (75 USgpm)
Pressures to 50 bar (725 psi)
Filters
HV3R Series

V3R * * * **

1 2 3 4 5

V3R Element 1Filter Element 3 Element Length 5 Fluid Cleanliness Rating


Model Code V3R - For use with HV3R mm (inch) Target fluid
series housings 1 - 114 (4.5) Code cleanliness level
Sample model code: 2 - 173 (6.8) *03 16/14/12 or better
2 Seal Material 4 - 356 (14)
V3RB1C05 *05 18/16/14 or better
B - Buna-N *10 20/18/15 or better
4 Element Construction
V - Viton-A *20 22/19/16 or better
C - C-Pak (code 03, 05, 10, 20)
H - H-Pak (code 03, 05, 10) * C - Pak only

Housing Dimensions Mounting Holes


3/8 - 24 X 14 (0.56) deep with SC (SAE-20) port option
mm (inch)
M10 with BC (G 1-1/4) port option

56
(2.2)

130
7.4 (5.12) Indicator Plug
(0.29)
Label
46.4
(1.83)
1 5/8-12UNF in. or G 1 1/4 port
SAE-20 port
2 PL'S

Refer to
Model Code

82.5
(3.25)
50.0 (1.97) 125
Clearance for (4.92)
Element Removal

Items not in bold are non-standard and may have a longer lead time
22 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Return Line Flows to 280 L/min (75 USgpm)
Pressures to 50 bar (725 psi)
Filters
Flow versus pressure drop:
HV3R Series 150 SUS (32 cSt) oil with specific gravity of <0.9
Flow Data

HV3R Filter Elements Flow Data

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 20

C -pak 1 0.013 (0.717) 0.009 (0.479) 0.005 (0.252) 0.004 (0.193)


2 0.008 (0.450) 0.006 (0.332) 0.004 (0.196) 0.002 (0.127)
4 0.004 (0.220) 0.003 (0.170) 0.002 (0.092) 0.001 (0.071)
H -pak 1 0.017 (0.919) 0.010 (0.569) 0.006 (0.321) xxx
2 0.011 (0.578) 0.007 (0.374) 0.004 (0.214) xxx
4 0.006 (0.312) 0.003 (0.184) 0.002 (0.097) xxx
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Housing/Bypass Valve Flow Data


Housing Bypass Valve
Flow Rate - USgpm Flow Rate - USgpm
13 40 66 13 40
1,4 5,0
Pressure drop - PSID

Pressure drop - PSID


1,2 17
Pressure drop - bar

Pressure drop - bar

4,0 58
1,0
0,8 12 3,0
0,6 2,0 29
0,4 6
1,0
0,2
0
0 50 100 150 200 250 300 0 50 100 150 200
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : HV3R1SC4RLB2C05 - Filter assembly having '2' length filter element with micron rating
code '05' at 100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.7x 0.8/0.9 + 100 x 0.006 x 46/32 x 0.8/0.9
= 0.620 + 0.76
= 1.38 bar

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 23


Return Line Flows to 1,700 L/min (450 USgpm)
Pressures to 25 bar (360 psi)
Filters
HV6R Series

Features and Benefits DESIGN SPECIFICATIONS

Beta Ratio: x(c) = 1,000 Rated flow: Length 5 1,300 L/min (343 USgpm)
to ISO 16889 Length 8 1,700 L/min (450 USgpm)
Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
Designed to comply with Optional seals available for phosphate esters.
ANSI specifications and
Temp range: -30C to *121C (-22F to *250F)
ISO cleanliness standards
Pressure rating: Operating 25 bar (360 psi)
Easy to remove cap to Fatigue 25 bar (360 psi)
facilitate element change
Material: Head, Housing, Lid Aluminum
and minimize spillage
Dry weight: Length 5 17 kg (37 lbs)
Vent and drain ports to (Approximate) Length 8 23 kg (50 lbs)
facilitate maintenance and
Port Size: 4in SAE Code 61 Flange with Metric threads (M16 bolts provided)
system start-up
Delta P visual, electrical,
and electrical indicators
with lamp options for
system design flexibility
High efficiency
replacement elements in
standard configurations
(C-Pak)
HV6R 1 * * ** * * * **

1 2 3 4 5 6 7 8 9

HV6R Series 1 Filter Series - HV6R QK - Electrical 1 bar (15 psi) UH - Electrical 4.9 bar (70 psi)
Filter and Element Hirschmann w 115V light Hirschmann
Model Code 2 Element Collapse Rating
QL - Electrical 1 bar (15 psi)
Hirschmann w 230V light 6 Seal Material
1 - 10 bar (150 psi) QH - Electrical 1 bar (15 psi) B - Buna-N
Sample model code: Hirschmann V - Viton-A
3 Mounting Options
HV6R1MT4RLB8C05 RB - Electrical 2 bar (30 psi)
F - In-line Brad Harrison 7 Assembly Length
T - In-tank RJ - Electrical 2 bar (30 psi) mm (inch)
Hirschmann w 24 volt 5 - 606 (23.9)
4 Valve Options light 8 - 1045 (41.1)
1 - Non-Bypass RK - Electrical 2 bar (30 psi)
2 - Bypass set at 1.7 bar Hirschmann w 115 volt 8 Element Construction
(25 psi) cracking pressure light C - Standard Construction
4 - Bypass set at 3 bar (43 psi) RL - Electrical 2 bar (30 psi) L - Deep pleat Construction
cracking pressure Hirschmann w 230 volt X - no element
light
5 Indicator Options RH - Electrical 2 bar (30 psi) 9 Fluid Cleanliness Rating
AN - Visual 4.9 bar (70 psi) Hirschmann Target fluid
No Connector UB - Electrical 4.9 bar (70 psi) Code cleanliness level
KN - Visual 1 bar (15 psi) Brad Harrison 03 16/14/12 or better
No Connector UJ - Electrical 4.9 bar (70 psi)
05 18/16/14 or better
LN - Visual 2 bar (30 psi) Hirschmann w 24 volt
No Connector light 10 20/18/15 or better
JN - No Indicator (plug), UK - Electrical 4.9 bar (70 psi) 20 22/19/16 or better
No Connector Hirschmann w 115 volt XX no element
QB - Electrical 1 bar (15 psi) light
Brad Harrison UL - Electrical 4.9 bar (70 psi)
QJ - Electrical 1 bar (15 psi) Hirschmann w 230 volt
Hirschmann w 24V light light

Items not in bold are non-standard and may have a longer lead time
24 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Return Line Flows to 1,700 L/min (450 USgpm)
Pressures to 25 bar (360 psi)
Filters
HV6R Series
V041 1 * * * **

1 2 3 4 5 6

V041 Element 1 Filter element 3 Seal material 6 Fluid cleanliness rating


Model Code V041 - For use with HV6R B - Buna-N Target fluid
series housings V - Viton-A
Code cleanliness level
Sample model code:
2Element collapse rating 4 Element length 03 16/14/12 or better
V0411B5L03 mm (inch) 05 18/16/14 or better
1 - 10 bar (150 psi)
Low Collapse 5 - 406 (16) 10 20/18/15 or better
8 - 990 (39) 20 22/19/16 or better
5 Element construction XX no element
C - C-Pak (code 03, 05, 10, 20)
L - L-Pak (code 03, 05, 10, 20)

Housing Dimensions In-line HV6R In-tank HV6R


mm (inch)
18
(0.71)
(4 places)

Clogging
Indicator G1/2 290
Port 130 Air Vent (11.42)
(5.12)
(Bolt Circle)
Clearance Required
for Element Changeout
Length 5
470
(18.50) 78 18
(3.06) Clearance Required (0.71)
for Element Changeout (4 places)
Length 8 260 770
915 (10.24) Venting (30.31)
(36.02) G 1/2

Length 5 352
606 G3/4 (13.86)
(23.86) Length 5 Fill Port INLET
606
Length 8 (23.86) 110
G1/2
1,045 Indicator (4.33)
(41.14) Length 8 Port
filling 1,045
INLET (41.14) Length 5
connection 232
G 3/4 (9.13) 254
(Tank (10.00)
78 Opening) Length 8
(3.06) 693
(27.28)

OUTLET Drain Plug OUTLET


G 1/2

Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 25
Return Line Flows to 1,700 L/min (450 USgpm)
Pressures to 25 bar (360 psi)
Filters
Flow versus pressure drop:
HV6R Series 150 SUS (32 cSt) oil with specific gravity of <0.9
Flow Data

HV6R Filter Elements Flow Data

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 20

C -pak 5 0.001 (0.055) 0.001 (0.046) 0.001 (0.026) 0.001 (0.014)


8 0.001 (0.023) 0.001 (0.019) 0.001 (0.011) 0.001 (0.006)
L -pak 5 0.001 (0.046) 0.001 (0.038) 0.001 (0.021) 0.001 (0.012)
8 0.001 (0.017) 0.001 (0.014) 0.001 (0.008) 0.001 (0.004)
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Housing/Bypass Valve Flow Data


Housing Bypass Valve

Flow Rate - USgpm Flow Rate - USgpm


79 238 396 79 238 396
0,2 2.9 7,0 100
6,0
Pressure drop - PSID

Pressure drop - PSID


0,15
Pressure drop - bar

Pressure drop - bar

5,0
4,0 58
0,10 1.5
3,0
2,0
0,05
1,0 15
0 0
0 300 600 900 1200 1500 0 300 600 900 1200 1500
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : HV6R1MT4RLB8C05 - Filter assembly having '8' length filter element with micron rating
code '05' at 200 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.) 0.8
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.01x 0.8/0.9 + 200 x 0.001 x 46/32 x 0.8/0.9
= 0.008 + 0.25
= 0.26 bar

26 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Return Line Flows to 1,700 L/min (450 USgpm)
Pressures to 25 bar (360 psi)
Filters
HV6RD Series

Features and Benefits DESIGN SPECIFICATIONS

Beta Ratio: x(c) = 1000 Rated flow: Length 1 1300 L/min (343 USgpm)
to ISO 16889 Length 2 1700 L/min (450 USgpm)
Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
Extremely large filtration Optional seals available for phosphate esters.
area and flow capacity
Temp range: -30C to +121C (-22F to +250F)
Designed for both in-tank Pressure rating: Operating 25 bar (360 psi)
and inline applications Fatigue 25 bar (360 psi)
Easy filter replacement Material: Head Aluminum
using screw-on lid Housing Aluminum
Manifolds Ductile Iron
Vent and drain ports are
standard Dry weight: Length 1 33,6 kg. (74 lbs)
(Approximate) Length 2 79,8 kg. (176 lbs)
Anodization is not Port size: 4 in SAE Code 61 Flange with metric threads (M16 bolts provided)
required for aluminum
alloy when using water For additional filtration HV6RD filters can be configured with multiple housings/elements
based fluids evenly mounted parallel to a single head. These configurations can be designed in evenly
Reusable contamination balanced series, for example: 2 x 2 would be 4 total elements with 2 on each side of the
basket prevents re-entry head. Contact Eaton to specify.
of retained contaminants
into the reservoir during
element replacement
HV6RD 1 * * * * * * ** *
Filters can be fitted with
clogging indicators to
1 2 3 4 5 6 7 8 9 10
monitor the contamination
level of the element
HV6RD duplex filters have 1 Filter Series - HV6RD MK - Electrical 1 bar (15 psi) 6 Seal Material
a ball-type selector valve Hirschmann w 115 volt
B - Buna-N
to provide continuous 2 light
Element Collapse Rating V - Viton-A
filtration and eliminate the ML - Electrical 1 bar (15 psi)
1 - 10 bar (150 psi) Low collapse Hirschmann w 230 volt
need to shut-down the 7 Assembly Length
system during element 3
light mm (inch)
Mounting Options MH - Electrical 1 bar (15 psi)
changeout F - Inline 1 - 606 (24)
Hirschmann 2 - 1045 (41)
Series HV6RD T - In-Tank RB - Electrical 2 bar (30 psi)
Filter Model Code Brad Harrison 8 Element Construction
4 Valve Options RJ - Electrical 2 bar (30 psi)
1- Non-Bypass C - Standard Construction
Hirschmann w 24 volt light
Sample model code: 2- Bypass set at 1.7 bar L - Deep Pleat Construction
RK - Electrical 2 bar (30 psi)
(25 psi) pressure X - no element
HV6RD1F2KNB1C05 Hirschmann w 115 volt
4- Bypass set at 3 bar light 9 Fluid Cleanliness Rating
(43 psi) cracking RL - Electrical 2 bar (30 psi)
Note: 6- Bypass set at 6 bar Hirschmann w 230 volt Target fluid
(87 psi) pressure light Code cleanliness level
Elements used in the HV6RD
are not dimensionally RH - Electrical 2 bar (30 psi) 03 16/14/12 or better
5 Indicator Options Hirschmann
equivalent to elements in the 05 18/16/14 or better
AN - Visual 4.9 bar (70 psi) UB - Electrical 4.9 bar (70 psi) 10 20/18/15 or better
HV6R series. An indicator is Brad Harrison
No Connector
supplied for each side. UJ - Electrical 4.9 bar (70 psi) 20 22/19/16 or better
KN - Visual 1 bar (15 psi)
No Connector Hirschmann w 24 volt light XX no element
LN - Visual 2 bar (30 psi) UK - Electrical 4.9 bar (70 psi)
No Connector Hirschmann w 115 volt 10 Flow Path
JN - No Indicator (plug), light A- Front inlet, front outlet
No Connector UL - Electrical 4.9 bar (70 psi) B- Front inlet, back outlet
MB - Electrical 1 bar (15 psi) Hirschmann w 230 volt C- Top inlet, front outlet
Brad Harrison light D- Top inlet, bottom outlet
MJ - Electrical 1 bar (15 psi) UH - Electrical 4.9 bar (70 psi) E- In-Tank mount
Hirshman w 24 volt light Hirschmann
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 27
Return Line Flows to 1,700 L/min (450 USgpm)
Pressures to 25 bar (360 psi)
Filters
HV6RD Series
V301 2 * * * *

1 2 3 4 5 6

V301 Element 1 Filter Element - V301 4 Element Length 6 Fluid Cleanliness Rating
model code mm (in) Target fluid
2 Element Collapse Rating 1 - 254 (10)
2 - 693 (27) Code cleanliness level
Sample model code: 2 - 17 bar (250 psi) Collapse
03 16/14/12 or better
V3012B1C10 3
5 Element Construction 05 18/16/14 or better
Seal Material
B - Buna-N C - C-pak (code 03, 05, 10, 20) 10 20/18/15 or better
V - Viton-A L - L-pak (code 03, 05, 10, 20) 20 22/19/16 or better

Housing Dimensions
Clearance Required
mm (inch) for Element Changeout
770 OUTLET OUTLET
In-tank (30.31)

352
Fill Port (13.86)
G 3/4
Indicator
Port
G 1/2

232
Length 1 (9.13)
606 (tank opening)
(23.86)
Length 1
Length 2 254
1045 (10.00)
(41.14)
Length 2
693
(27.28)

OUTLET OUTLET
18
(0.71) INLET
(8 places)

135
(5.31)
280
(11.02)

Vent Plug
G 1/2

290 510
(11.42) (20.08)
Bolt Circle
Items not in bold are non-standard and may have a longer lead time
28 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Return Line
Filters
Venting G 1/2
HV6RD Series

Housing
Dimensions
mm (inch)
In-Line

Filling
Connection

(16) Element - 858mm


(39) Element - 1,502mm

Clogging Indicator
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 29
Return Line Flows to 1,700 L/min (450 USgpm)
Pressures to 25 bar (360 psi)
Filters
Flow versus pressure drop:
HV6RD Series 150 SUS (32 cSt) oil with specific gravity of <0.9
Flow Data

HV6RD Filter Elements Flow Data

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 20

C -pak 1 0.001 (0.055) 0.001 (0.046) 0.001 (0.026) 0.001 (0.014)


2 0.001 (0.023) 0.001 (0.019) 0.001 (0.011) 0.001 (0.006)
L -pak 1 0.001 (0.046) 0.001 (0.038) 0.001 (0.021) 0.001 (0.012)
2 0.001 (0.017) 0.001 (0.014) 0.001 (0.008) 0.001 (0.004)
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Housing/Bypass Valve Flow Data


Housing Bypass Valve
Flow Rate - USgpm Flow Rate - USgpm
132 264 396 528 79 238 396
1.00 15 7,0 100
6,0
Pressure drop - PSID

Pressure drop - PSID


0.75 11
Pressure drop - bar

Pressure drop - bar

5,0
4,0 58
0.50 8
3,0
2,0
0.25 4
1,0 15
0 0
0 500 1000 1500 2000 0 300 600 900 1200 1500
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : HV6RD1F2ANB1C05 - Filter assembly having '1' length filter element with micron rating code
'05' at 200 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.05 x 0.8/0.9 + 200 x 0.001 x 46/32 x 0.8/0.9
= 0.044 + 0.25
= 0.44 bar

Items not in bold are non-standard and may have a longer lead time
30 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Return Line Flows to 115 L/min (30 USgpm)
Pressures to 40 bar (600 psi)
Filters
OFR30 Series

Features and Benefits DESIGN SPECIFICATIONS

OFR-30 conforms to HF3 Rated flow: 115 L/min (30 US gpm)


specifications Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
Flows to 115 L/min Temp range: -40C to +107C (- 40F to +225F)
(30 USgpm) Pressure rating: Operating 40 bar (600 psi)
Visual indicator is standard Bypass setting: 1.7 bar (25 psi)
Material: Head Die cast aluminum
Electrical indicator also Bowl Carbon steel
available
Dry weight: (Approximate) 5,4 kg (12lbs)
Bypass valve is standard
Replacement elements
available in C-Pak

OFR 30 * * * ** * 30

1 2 3 4 5 6 7 8

OFR30 Series 1 Filter Type - OFR 5 Element Construction 8 Design


Filter and Element C - C-Pak (code 03, 05 10, 20) 30 - Standard Design
Model Code 2 Flow Capacity X - no element
30 - 115 L/min (30 USgpm)
6 Fluid Cleanliness Rating
Sample model code:
3 Port Options Target Fluid
OFR30SBC03M30 Code cleanliness level
B - G1 (formerly 1" BSPF)
thread 03 16/14/12
F - 1" SAE 4-bolt flange 05 18/16/14
Code 61 10 20/18/15
S - 1.3125-12 UN SAE-16 20 22/19/16
straight thread 1" O.D.
tube XX no element

4 Seal Material 7 Delta Indicator Options


B - Buna M - Mechanical 1.7 bar (25psi)
V - Viton E - Electrical 1.7 bar (25psi)

Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 31
Return Line Flows to 115 L/min (30 USgpm)
Pressures to 40 bar (600 psi)
Filters
V602 1 * 2 C **
OFR30 Series 1 2 3 4 5 6

V602 Element 1 Filter Element -V602 4 Element Length 6 Fluid Cleanliness Ratings
Model Codes mm (inch) Target fluid
(Meets HF3 Specifications) 2 Element Collapse Rating 2 - 203 (8) (HF3 length) Code cleanliness level
1 - 10 bar (150 psi) Low 03 16/14/12
Sample model code: 5 Element Construction
Collapse 05 18/16/14
V6021B2C03 C - C-Pak (code 03, 05, 10, 20) 10 20/18/15
3 Seals
20 22/19/16
B - Buna-N
V - Viton-A

Housing Dimensions
Memory 52,3 (2.06) 3 / -16
UNC-2B
Mechanical Indicator 8
reset knob 26,2 (1.03) 0.64 min. full thread
mm (inch) 2-places
Visual indicator
13,2
(0.52)
269,7
133,4 (5.25) (10.62)
218,9 OFR-15
66,5 (8.62) 362,0
(2.62) Inlet port OFR-15 (14.25)
311,2 OFR30
180,8
(7.12) (12.25)
26,2 OFR15 OFR30
(1.03)
131,8 273,1
Outlet port (5.19) (10.75)
OFR30
66,5
(2.62)
Drain plug

98,6 Dia. 25,4 (1.00) Clearance


(3.88) for element removal
Electrical Indicator
mm (inch)

87,4
1/2 NPTF thd. (3.44)

Connections
1.312-12 UN SAE 99,3
1" G1 British (3.91)
pipe thread or
1" SAE 4-bolt flg.
Torque head bolts to 267,5
25-30 ft.lbs (33-41 Nm) (10.53)
177,8 OFR-15
(7.00) 53,8 (2.12)
min. lead extension 359,7
(14.16)
OFR-30
Electrical Indicator Green
Switch Circuit

Blue C NC
NO
Red
Black

Items not in bold are non-standard and may have a longer lead time
32 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Return Line Flows to 115 L/min (30 USgpm)
Pressures to 40 bar (600 psi)
Filters
Flow versus pressure drop:
OFR 30 Series 150 SUS (32 cSt) oil with specific gravity of < 0.9
Flow Data

Element Flow Data

OFR30 C-Pak

Flow Rate - USgpm


5 15 25 35 45 55 65 75

1,7 25

Pressure drop - psid


Pressure drop-bar

C03
1,4 20
1,0 05 15
0,7 10
10
0,3 5
20
0
0 50 100 150 200 250
Flow Rate - L/min

Housing/Bypass Valve Flow Data

Housing Bypass Valve


Flow Rate - USgpm
Flow Rate - USgpm
20 33
0,5 40 66 92
3,0
0,4 6
Pressure drop - psid
Pressure drop-bar

2,5 36

Pressure drop - psid


1.75 bar cracking
Pressure drop-bar

0,3 2,0

1,5 22
0,2 OFR-30 3
1,0
0,1 0,5
0
0 25 50 75 100 125 150 50 100 150 200 250 300 350 400 450
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : OFR30SBC03M30 - Filter assembly having filter element with micron rating code '03' at 100
L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.22 x 0.8/0.9 + 0.5 x 46/32 x 0.8/0.9
= 0.193 + 0.632
= 0.83 bar

Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 33
Return Line Flows to 450 L/min (120 USgpm)
Pressures to 27 bar (400 psi)
Filters
OFR 60/120
Series

Features and Benefits DESIGN SPECIFICATIONS

Visual indicator is standard Rated flow: OFR60 225 L/min (60 USgpm)
OFR120 450 L/min (120 USgpm)
Electrical indicator also Fluid compatibility: Compatible with most petroleum oil, water
available glycol, oil-in-water and water-in-oil fluids.
Bypass valve is standard Temp range: -40C to +107C (-40F to +225F)
Replacement elements Pressure rating: Operating 27 bar (400 psi)
available in C-Pak Material: Head Die cast aluminum
Bowl Carbon steel
Dry weight: OFR60 6,8 kg (15 lbs)
(Approximate) OFR120 9,5 kg (21 lbs)

OFR *** * * * ** * ** 30

1 2 3 4 5 6 7 8 9

OFR 60/120 Series 1 Filter Type 5 Element Construction 8 Bypass Setting


Filter and Element OFR - Oil filter return line C - C-Pak (code 03, 05 10, 20) 25 - Bypass set at 1.7 bar
Model Code X - no element (25 psi) Standard cracking
2 Flow Capacity pressure
6 Fluid cleanliness rating 35 - Bypass set at 2 bar
Sample model code: 060 - 227 L/min (60 USgpm)
120 - 454 L/min (120 USgpm) Target fluid (35 psi) cracking pressure
OFR060SBC03M2530 Code cleanliness level 50 - Bypass set at 3 bar
3 Port Options 03 16/14/12 (50 psi) cracking
F - 1-1/2" SAE 4-bolt flange 05 18/16/14 pressure**
Code 61 ** CAUTION
10 20/18/15
S - 1.875-12 UN SAE-24
Applications involving
20 22/19/16 high flow surges may cause
straight thread for 1-1/2"
O.D. tube XX no element element collapse due to
instantaneous pressure spikes.
4 Seal Material 7 P Indicator Options
9 Design
B - Buna M - Mechanical
V - Viton E - Electrical 30 - Standard Design

Items not in bold are non-standard and may have a longer lead time
34 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Return Line Flows to 450 L/min (120 USgpm)
Pressures to 27 bar (400 psi)
Filters
OFR 60/120 V405 1 * * C **
Series
1 2 3 4 5 6

V405 Element 1 Filter Element - V405 4 Element Length 6Fluid Cleanliness Rating
Model Code mm (inch) Target fluid
2 Element Collapse Rating 3 - 229 (9) (Use in OFR-60)* Code cleanliness level
(Meets HF4 Standard)
1 - 10 bar (150 psi) 6 - 457 (18) (Use in OFR-120) 03 16/14/12
Sample model code: 05 18/16/14
3 5 Element Construction
Seals 10 20/18/15
V4051B3C03 B - Buna-N C - C-Pak (code 03, 05, 10, 20) 20 22/19/16
V - Viton-A
*NOTE: Two 9 inch elements and a P-227567-01 reusable connector can also
be used in the OFR-120 housing. This arrangement meets HF4 specifications.

Housing Dimensions

Mechanical Indicator Memory


mm (inch) reset 88,9
(3.50) 44,5 .500-13UNC-2B thd.
168,1 (6.62) knob .75 deep 2 holes for mounting
Outlet (1.75)
port Visual
84,1 indicator
(3.31) Inlet port 93,0
(3.66)
19,1 (0.75)
162,1
(6.38)
66,5 81,0
(2.62) (3.19)

320,5 550,9
Note: (12.62) (21.69)
Plastic plug, part number OFR60 OFR120
737365, is installed in the
filter element to close the
end of the element. When
servicing element, remove Drain plug
and retain plastic plug
737365. Install new element
with plastic plug on bottom. 117,9 Dia.
(4.64) 25,4 (1.00) Clearance
for element removal

Electrical Indicator
mm (inch) 1/2 NPTF thd. 90,9
(3.58)

119,1
177,8 (7.00) min. A port Conn. (4.69)
lead extension 2 places
Torque head bolts to
53,8 (2.12) 50 ft.lbs (67,79 Nm) dry
35 ft.lbs. (47,45 Nm)
lubricated
Electrical Indicator Green
Switch Circuit
Blue C NC
NO
Red
Black

Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 35
Return Line Flows to 450 L/min (120 USgpm)
Pressures to 27 bar (400 psi)
Filters
Flow versus pressure drop:
OFR 60/120 150 SUS (32 cSt) oil with specific gravity of <0.9
Series
Flow Data

Element Flow Data

OFR60 C-Pak Element OFR120 C-Pak Element

Flow Rate - USgpm Flow Rate - USgpm


10 20 30 40 50 20 40 60 80 100

Pressure drop - PSID

Pressure drop - PSID


C03
Pressure drop-bar

C03

Pressure drop-bar
0,6 8 0,6 8
0,4 05 6 0,4 05 6
0,3 10 4 0,3 4
10
0,1 2 0,1 2
20 20
0 0
0 50 100 150 50 100 150 200 250 300 350
Flow Rate - L/min Flow Rate - L/min

Housing/Bypass Valve Flow Data

Housing Bypass Valve

Flow Rate - USgpm Flow Rate - USgpm


53 106 53 106
1,00 15
3,00 44
Pressure drop - PSID

Pressure drop - PSID


0,75
Pressure drop-bar

Pressure drop-bar

2,50
2,00 29
0,50 OFR-120 7
1,50
1,00 15
0,25 OFR-60
0,50

0 0
0 100 200 300 400 500 0 100 200 300 400
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : OFR060SBC03M2530 - Filter assembly having a filter element with micron rating code '03' at
200 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.2 x 0.8/0.9 + 0.7 x 46/32 x 0.8/0.9
= 0.170 + 0.885
= 1.07 bar

Items not in bold are non-standard and may have a longer lead time
36 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Return Line Flows to 400 L/min (106 USgpm)
Pressures to 25 bar (363 psi)
Filters
DLR DIN Series
Filters

Features and Benefits DESIGN SPECIFICATIONS

Beta Ratio: x(c) = 1000 Rated flow: 160 160 L/min (42.2 USgpm)
250 250 L/min (66.0 USgpm)
to ISO 16889 400 400 L/min (105.7 USgpm)
Visual, electrical and Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
electrical indicators with Optional seals available for phosphate esters
light options for system Temp range: -30C to +100C (-22F to +212F)
design flexibility Pressure rating: Operating 25 bar (363 psi)
Fully serviceable without Material: Aluminum
tools
Dry weight: 160 4,3 kg (9.5 lbs)
Zero leak by-pass valve 250 4,9 kg (10.8 lbs)
construction 400 5,9 kg (13.0 lbs)
Wide range of element
lengths for maximum
design flexibility
High efficiency
replacement elements
in standard configurations
(C-Pak) to meet Target
Cleanliness Levels

DLR 1 *** ** * ** * * **

1 2 3 4 5 6 7 8 9

DLR Series Filter 1 Filter Series 5 Valve Options 8 Element Construction


DLR - DIN Low Pressure 1 - Non-Bypass C - Standard Construction
Sample model code: Return 6 - 7 Bar (100 psi) X - no element
DLR1160BE6ANBC03 2 6 9
Element Collapse Rating Indicator Options Fluid Cleanliness Rating
1 - Low Collapse AN - Visual 4.9 bar (70 psi) Target fluid
No Connector Code cleanliness level
3 Nominal Size JN - No Indicator, No 03 16/14/12 or better
160 - 160L/min (42.2USgpm) Connector 06 18/16/14 or better
250 - 250L/min (66.0USgpm) TH - Electrical 4.9 bar (70 psi) 10 20/18/15 or better
400 - 400L/min (105.7USgpm) Hirschmann
25 22/19/16 or better
4 Port Size 7 Seal Material XX no element
BE - G 1-1/4 (Length 160 only) B - Buna-N
BF - G 1-1/2 (Length 250 only) V - Viton-A
BK - 1-1/2" SAE Flange Code
61 with M16 bolts (DN38)
(Length 400 only)

Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 37
Return Line Flows to 400 L/min (106 USgpm)
Pressures to 25 bar (363 psi)
Filters
DLR DIN Series
Filters
VDP *** * C **

1 2 3 4 5

Element model code 1 Filter Element 3 Seal Material 5 Fluid Cleanliness Rating
VDP - DIN Standard Element B - Buna-N Target fluid
Sample model code: V - Viton-A Code cleanliness level
2 Nominal Size - Flow 03 16/14/12 or better
VDP160BC06 4
Assembly Length Element Construction 06 18/16/14 or better
160 - 160L/min (42.2USgpm) C - Standard Construction 10 20/18/15 or better
297mm(11.7") 25 22/19/16 or better
250 - 250L/min (66.0USgpm)
375mm(14.8")
400 - 400L/min
(105.7USgpm)
525mm(20.7")

DLR Housing
Dimensions in mm 43.5

Outlet
Inlet Port Size
See Chart

HI

TYPE HI PORT SIZE

DLR 160 285 G 1 1/4


DLR 250 363 G 1 1/2
DLR 400 513 DN38

Drain Plug

150 M10 x 18 Mounting Holes

Connection for Indicator

130 60 0.2

Items not in bold are non-standard and may have a longer lead time
F
38 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007

F
Return Line Flows to 400 L/min (106 USgpm)
Pressures to 25 bar (363 psi)
Filters
DLR DIN Series
Filters

DLR DIN Filter Elements Flow Data

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 6 10 25

C -pak 160 0.013 (0.717) 0.009 (0.479) 0.005 (0.252) 0.004 (0.193)
250 0.005 (0.275) 0.003 (0.178) 0.002 (0.111) 0.001 (0.091)
400 0.003 (0.178) 0.002 (0.111) 0.001 (0.073) 0.001 (0.055)
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

DLR 160/250/400 Housing

Flow Rate - USgpm


0 13 26 40 52 66 79 92 106
0.80 12.0
0.70 10.5
0.60 9.0
0.50 7.5
P in psid
P in bar

0.40 6.0
0.30 4.5
0.20 3.0
0.10 1.5
0.00 0.0
0 50 100 150 200 250 300 350 400
Flow Rate - L/min

Sample P Calculation : DLR1160BE6ANBC03 - Filter assembly having '160' size filter element with micron rating
code '03' at 100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.8x 0.8/0.9 + 100 x 0.013 x 46/32 x 0.8/0.9
= 0.700 + 1.65
= 2.35 bar

Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 39
Return Line Flows to 400 L/min (105 USgpm)
Pressures to 25 bar (360 psi)
Filters
LND Duplex

Features and Benefits DESIGN SPECIFICATIONS

Beta Ratio: x(c) = 1000 Rated flow: Length 1 160 L/min (42 USgpm)
to ISO 16889 Length 2 250 L/min (66 USgpm)
Length 4 400 L/min (105 USgpm)
Lightweight duplex filter Fluid compatibility: Compatible with all petroleum oils and synthetic fluids rated for use with
constructed of aluminum Fluoro-Rubber or Ethylene Propylene seals.
Aluminum alloy is water Temp range: -30C to + 121C (-22F to 250F)
tolerant - anodization is Pressure rating: Operating 25 bar (360 psi)
not required for high Fatigue 25 bar (360 psi)
water based fluids Material: Aluminum
(HWBF)
Dry weight: Length 1 10,3 kg (22.7 lbs)
The screw-in bowl allows (Approximate) Length 2 11,6 kg (25.6 lbs)
the filter element to be Length 4 13,0 kg (28.7 lbs)
easily removed for
replacement or cleaning
The standard model is
supplied with vent and
drain plugs and also a
connection for differential
clogging indicator
LND 1 SD * ** * * * **

1 2 3 4 5 6 7 8 9

LND Series 1 Filter Series - LND RJ - Electrical 2 bar (30 psi) 7 Assembly Length
Filter and Element Hirschmann w 24 volt
mm (inch)
Model Code 2 light
Element Collapse Rating 1 - 297 (11.7")
RK - Electrical 2 bar (30 psi)
1 - 250 psi Low Collapse 2 - 375 (14.8")
Hirschmann w 115 volt
Sample model code: 4 - 525 (20.7)
3
light
Port Options RL - Electrical 2 bar (30 psi)
LND1SD7ANV2C05 8 Element Construction
SD - 1.875 - 12 UN SAE - 24 Hirschmann w 230 volt
Straight thread light C - Standard Construction
UB - Electrical 4.9 bar (70 psi) X - no element
4 Valve Options Brad Harrison 9
1 - Non-Bypass UH - Electrical 4.9 bar (70 psi) Fluid Cleanliness Rating
4 - Bypass set at 2.9 bar Hirschmann Target fluid
(43 psi) cracking pressure UJ - Electrical 4.9 bar (70 psi) Code cleanliness level
7 - Bypass set at 7 bar (102 Hirschmann w 24 volt 03 16/14/12 or better
psi) cracking pressure light 05 18/16/14 or better
UK - Electrical 4.9 bar (70 psi) 10 20/18/15 or better
5Indicator Options Hirschmann w 115 volt 20 22/19/16 or better
AN - Visual 4.9 bar (70 psi) light
UL - Electrical 4.9 bar (70 psi) XX no element
No Connector
JN - No Indicator (plug), Hirschmann w 230 volt
No Connector light
LN - Visual 2 bar (30 psi)
6 Seal Material
No Connector
RB - Electrical 2 bar (30 psi) B - Buna-N
Brad Harrison V - Viton-A
RH - Electrical 2 bar (30 psi)
Hirshmann

Items not in bold are non-standard and may have a longer lead time
40 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Return Line Flows to 400 L/min (105 USgpm)
Pressures to 25 bar (360 psi)
Filters
LND Duplex VDP *** * C **

1 2 3 4 5

Element model code 1Filter Element 3 Seal Material 5 Fluid Cleanliness Rating
VDP - DIN Standard Element B - Buna-N Target fluid
Sample model code: V - Viton-A Code cleanliness level
2 Nominal Size - Flow 03 16/14/12 or better
VDP160BC06 4
(2 elements required) Assembly Length Element Construction 06 18/16/14 or better
160 - 160L/min (42.2USgpm) C - Standard Construction 10 20/18/15 or better
297mm(11.7") 25 22/19/16 or better
250 - 250L/min (66.0USgpm)
375mm(14.8")
400 - 400L/min
(105.7USgpm)
Housing Dimensions 525mm(20.7")
mm (inch)
vent "clean side" SW 5
(connection G 3.175)
210
(8.27) mounting holes
9.525 - 24 UNF
(19.05 deep - 4 places)

62
(2.44)
vent "contamination side" SW 5
(connection G .125)

282
(11.10) G 1/2" Indicator Port

Inlet Outlet

Length 1
297
(11.69)

Length 2
375
(14.76)

Length 4
525
(20.67)

Drain Plug
100 G 12.7
(3.94)
85 130
(3.34) (5.12)
Clearance required
for element removal
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 41
Return Line Flows to 400 L/min (105 USgpm)
Pressures to 25 bar (360 psi)
Filters
Flow versus pressure drop:
LND Duplex 150 SUS (32 cSt) oil with specific gravity of <0.9
Flow Data

LND Filter Elements Flow Data

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 25

C -pak 1 0.013 (0.717) 0.009 (0.479) 0.005 (0.252) 0.004 (0.193)


2 0.005 (0.275) 0.003 (0.178) 0.002 (0.111) 0.001 (0.091)
4 0.003 (0.178) 0.002 (0.111) 0.001 (0.073) 0.001 (0.055)
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Housing/Bypass Valve Flow Data

Flow Rate - USgpm


0 25 50 75 100
2,0 30.0
Pressure Drop - bar

22.5
Pressure Drop - psi

1,5

1,0 15.0

0,5 7.5

0 0
0 100 200 300
Flow Rate - L/min

Sample P Calculation : LND1SD1ANV2C05 - Filter assembly having '2' length filter element with micron rating code
'05' at 100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.2 x 0.8/0.9 + 100 x 0.003 x 46/32 x 0.8/0.9
= 0.170 + 0.38
= 0.55 bar

Items not in bold are non-standard and may have a longer lead time
42 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Notes

Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 43
In-tank Filters

General Data
In-tank filters are a special type of low pressure return The filter housing may be equipped with diffusers
line filters. In-tank filters are mounted directly to the to ensure that the returning oil energy is gradually
reservoir tank top and have an accessible head that is dissipated within the reservoir fluid to minimize
located outside of the reservoir while the body of the the potential for aerating or foaming of the oil. In
housing is located inside the reservoir. The exposed addition, the diffuser helps direct the fluid outward
cover allows the element to be easily replaced as against the walls of the reservoir to aid in the heat
needed. transfer capability of the reservoir.

Applications
Forestry harvesting
equipment such as
delimbers and feller
bunchers
Injection molding or blow
molding equipment
Offshore drilling platform
power units
Machine tools
Die cast machines

Items not in bold are non-standard and may have a longer lead time
44 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
In-tank Filters Flows to 50 L/min (13.2 USgpm)
Pressures to 7 bar (100 psi)
OFMT020 Series

Features and Benefits DESIGN SPECIFICATIONS

High efficiency filter Rated flow: Length 1 30 L/min (7.9 USgpm)


Length 2 35 L/min (9.2 USgpm)
elements with superior Length 3 50 L/min (13.2 USgpm)
dirt-holding capacity
Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water
designed for return lines and water-in-oil fluids
and installed semi-
Temp range: -25C to +110C (-13F to +230F)
immersed in a reservoir
Pressure rating: Operating 7 bar (100 psi)
Excellent pressure drop Fatigue 7 bar (100 psi)
characteristics Material: Head Die Cast Aluminum
P indicator options for Cover Nylon
flexibility in system design Bowl Nylon
Dry weight: Length 1 0,3 kg. (0.66 lbs.)
Bowl length options for (Approximate) Length 2 0,4 kg. (0.88 lbs.)
design flexibility Length 3 0,5 kg. (1.10 lbs.)
Easy element changes
Bypass valve prevents
excessive pressure drop
and prevents element
collapse and release of
retained contaminants
back into hydraulic system OFMT020 * * * ** A** H B T
Designed to comply with
ISO standards 1 2 3 4 5 6 7 8 9

OFMT 020 Series 1 Filter Series - OFMT020 5Port Options 7 Element Collapse Rating
Filter and Element G1 - G 3/8 to ISO 228 H - 10 bar (150 psi)
Model Code 2 Assembly Length G2 - G 1/2 to ISO 228
G4 - 3/8" NPT 8 Valve Options
mm (inch)
Sample model code: 1 - 102 (4.0) G5 - 1/2" NPT B - Bypass set at 1.7 bar
2 - 165 (6.5) G7 - 0.5625 - 18 UN SAE-6 (25 psi) cracking pressure
OFMT0201SAG7A06HBT 3 - 210 (8.3) Straight thread
G8 - 0.75 - 16 UN SAE-8 9 Indicator Options
3 Breather Options Straight thread T - No Indicator (plug),
S - No breather 6
No Connector
C - 10 m breather Fluid Cleanliness Rating
M - 40 m breather Target fluid
Code cleanliness level
4 Seal Material A03 16/14/12 or better
A - Buna-N A06 18/16/14 or better
V - Viton-A A10 20/18/15 or better

Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 45
In-tank Filters Flows to 50 L/min (13.2 USgpm)
Pressures to 7 bar (100 psi)
OFMT020 Series

FM020 * A** H *

1 2 3 4 5

Element model code 1 Filter Element - FM 020 3 Fluid Cleanliness Rating 4 Element Collapse Rating
Target fluid H - 10 bar (150 psi)
Sample model code: 2 Asembly Length Code cleanliness level
A03 16/15/12 or better 5 Seal Material
FM0202A06HA mm (inch)
1 - 102 (4.0) A06 18/16/14 or better A - Buna-N
2 - 165 (6.5) A10 19/17/14 or better V - Viton-A
3 - 210 (8.3) Note: Element comes with
bypass set at 25 psi cracking
pressure

Housing Dimensions
mm (inch)

60 (2.36 48 (1.89)
R 11,5 (0.45)

84 88
(3.31) (3.46)

Holes required on tank

46 (1.81) M10
R 5,5 (0.22)
61 (2.40)

62
(2.44)

21 (0.83)
84/88 (3.31/3.46)
Anti-splash

H
24 (0.94)

27 (1.06)
51 (2.01)

Items not in bold are non-standard and may have a longer lead time
46 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
In-tank Filters Flows to 50 L/min (13.2 USgpm)
Pressures to 7 bar (100 psi)
OFMT020 Series
Flow Data

Element Flow Data

OFMT020 H-Pak Length 1 OFMT020 H-Pak Length 2


Flow rate - USgpm Flow rate - USgpm
0.0 2.6 5.3 7.9 10.6 13.2 15.6 0.0 2.6 5.3 7.9 10.6 13.2 15.6
1,00 15.0 1,00 15.0
03 03

Pressure drop - psid

Pressure drop - psid


10 06
Pressure drop - bar

Pressure drop - bar


06
0,75 10.9 0,75 10.9
10
0,50 7.2 0,50 7.2
0,25 3.6 0,25
0 3.6
0,00 0.0 0,00 0.0
0 10 20 30 40 50 60 0 10 20 30 40 50 60
Flow rate - L/min Flow rate - L/min
OFMT020 H-Pak Length 3
Flow rate - USgpm
0 4.0 7.9 11.9 15.9 19.8 23.8
1,00 15.0
03
Pressure drop - psid
Pressure drop - bar

0,75 10.9
06
00,50 7.2
10
0,25 3.6
0,00 0.0
0 15 30 45 60 75 90
Flow rate - L/min
Housing/Bypass Valve Flow Data
Housing Bypass Valve
Based on mineral oil with density of 0,86 kg/dm
P varies proportionally to density.
Flow rate - USgpm Flow rate - USgpm
0 6.6 13.2 19.8 26.4 33.0 0 4 8 12 16 20 24
0,4 6.0 3 45
1/2

0,3 4.5

Pressure drop - psid


Pressure drop - psid

2 30
Pressure drop - bar
Pressure drop - bar

0,2 3.0

1 15
0,1 1.5

0,0 0 0.0 0 0
0 25 50 75 100 125 0 15 30 45 60 75 90
Flow rate - L/min Flow rate - L/min
Sample P Calculation : OFMT0201SAG7A06HBT - Filter assembly having filter element with micron rating code '06'
at 25 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.02 x 0.8/0.9 + 0.5 x 46/32 x 0.8/0.9
= 0.017 + 0.632
= 0.65 bar
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 47
In-tank Filters Flows to 70 L/min (18.5 USgpm)
Pressures to 7 bar (100 psi)
OFMT100 Series

Features and Benefits DESIGN SPECIFICATIONS

High efficiency filter Rated flow: Length 1 35 L/min (9.2 USgpm)


Length 2 45 L/min (11.9 USgpm)
elements with superior Length 3 70 L/min (18.5 USgpm)
dirt-holding capacity
Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water
designed for return lines and water-in-oil fluids
and installed semi-
Temp range: -25C to +110C (-13F to +230F)
immersed in a reservoir
Pressure rating: Operating 7 bar (100 psi)
Excellent pressure drop Fatigue 7 bar (100 psi)
characteristics Material: Head Die Cast Aluminum
P indicator options for Cover and Bowl Nylon
flexibility in system design Dry weight: Length 1 0,3 kg. (0.66 lbs.)
(Approximate) Length 2 0,4 kg. (0.88 lbs.)
Bowl length options for Length 3 0,5 kg. (1.10 lbs.)
design flexibility
Easy element changes
Bypass valve prevents
excessive pressure drop
and prevents element
collapse and release of OFMT100 * * * G* A** H B T
retained contaminants
back into hydraulic system 1 2 3 4 5 6 7 8 9
Designed to comply with
ISO standards 1 5 7
Filter Series - OFMT 100 Port Options Element Collapse Rating
G1 - G 3/4 to ISO 228 H - 10 bar (150 psi)
2 Assembly Length G2 - G 1 to ISO 228
OFMT 100 Series mm (inch) G3 - G 1-1/4 to ISO 228 8 Valve Options
Filter and Element 1 - 102 (4.0) G4 - 3/4" NPT B - Bypass set at 1.7 bar
Model Code 2 - 145 (5.7) G5 - 1" NPT (25 psi) cracking pressure
3 - 225 (8.9) G6 - 1.0625 - 12 UN SAE -
Sample model code: 12 Straight thread 9 Indicator Options
3 Breather Options G7 - 1.3125 - 12 UN SAE - T - No Indicator (plug), No
OFMT1001SAG7A06HBT S - No breather 16 Straight thread Connector
C - 10 m breather G8 - 1.625 - 12 UN SAE -
M - 40 m breather 20 Straight thread

4 6
Fluid Cleanliness Rating
Seal Material
A - Buna-N Target fluid
V - Viton-A Code cleanliness level
A03 16/14/12 or better
A06 18/16/14 or better
A10 20/18/15 or better

Items not in bold are non-standard and may have a longer lead time
48 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
In-tank Filters Flows to 70 L/min (18.5 USgpm)
Pressures to 7 bar (100 psi))
OFMT100 Series

FM100 * A** H *

1 2 3 4 5

Element model code 1 Filter Element - FM 100 3 Fluid Cleanliness Rating 4 Element Collapse Rating
Target fluid H - 10 bar (150 psi)
2 Assembly Length Code cleanliness level
A03 16/15/12 or better 5 Seal Material
Sample model code: mm (inch)
1 - 102 (4.0) A06 18/16/14 or better A - Buna-N
FM1002A06HA 2 - 145 (5.7) V - Viton-A
A10 19/17/14 or better
3 - 225 (8.9) Note: Element comes with
bypass set at 25 psi cracking
pressure

Housing Dimensions
mm (inch)

9 (0.35) A

54
(2.13)
116
(4.57)

R 11,5 (0.45)
71 (2.80)
76 (2.99)
108 (4.25)
Holes required on tank
68 (2.68)
95 26
(3.74) (1.02) 87/90 M8
(3.43/3.54)
32 (1.26)

40 (1.57)
20 (0.79) 116
only for air (4.57)
breather

48 C indicator connection
(1.89) 59 (2.32)

H 86 (3.39)
111 (4.37)

24 (0.94) 38 (1.50)

80 (3.15)

Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 49
In-tank Filters Flows to 70 L/min (18.5 USgpm)
Pressures to 7 bar (100 psi))
OFMT100 Series
Flow Data

Element Flow Data


OFMT100 H-Pak Length 1
Flow rate - USgpm
0.0 6.6 13.2 19.8 26.4 33.0 39.6
1,00 15.0

Pressure drop - psid


Pressure drop - bar

03 10
06
0,75 10.9
0,50 7.2
0,25 3.6
0,00 0.0
0 25 50 75 100 125 150
Flow rate - L/min

OFMT100 H-Pak Length 2 OFMT100 H-Pak Length 3


Flow rate - USgpm Flow rate - USgpm
0.0 6.6 13.2 19.8 26.4 33.0 39.6 0.0 6.6 13.2 19.8 26.4 33.0 39.6
1,00 15.0 1,00 15.0
Pressure drop - psid

Pressure drop - psid


Pressure drop - bar

Pressure drop - bar


03 06 03
10 06
0,75 10.9 0,75 10.9
10
0,50 7.2 0,50 7.2
0,25 3.6 0,25 3.6
0,00 0.0 0,00 0.0
0 25 50 75 100 125 150 0 25 50 75 100 125 150
Flow rate - L/min Flow rate - L/min

Housing/Bypass Valve Flow Data F

Housing Bypass Valve


3
Based on mineral oil with density of 0,86 kg/dm .
P varies proportionally to density.
Flow Rate - USgpm Flow Rate - USgpm
0 13.2 26.4 39.6 52.8 66.0 0 6.6 13.2 19.8 26.4 33.0 39.6
0,4 6.0 4 60
3/4
Pressure drop - psid

Pressure drop - psid


Pressure drop - bar
Pressure drop - bar

0,3 4.5 3 45

0,2 3.0 2 30
1
0,1 1.5 1 15
1-1/4
0,0 0.0 0 0
0 50 100 150 200 250 0 25 50 75 100 125 150
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : OFMT1001SAG7A06HBT - Filter assembly having filter element with micron rating code '06'
at 50 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.015 x 0.8/0.9 + 0.55 x 46/32 x 0.8/0.9
= 0.013 + 0.695
= 0.71 bar
50 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
In-tank Filters Flows to 105 L/min (27.7 USgpm)
Pressures to 10 bar (150 psi)
OFRT100 Series

Features and Benefits DESIGN SPECIFICATIONS

High efficiency filter Rated flow: Length 1 35 L/min (9.2 USgpm)


Length 2 40 L/min (10.6 USgpm)
elements with superior Length 3 75 L/min (19.8 USgpm)
dirt-holding capacity Length 4 105 L/min (27.7 USgpm)
designed for return lines Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water
and installed semi- and water-in-oil fluids, Optional seals available for phosphate esters.
immersed in a reservoir Temp range: -25C to 110C (-13F to 230F)
Excellent pressure drop Pressure rating: Operating 10 bar (150 psi)
characteristics Fatigue 10 bar (150 psi)
Indicators ordered Material: Head Die Cast Aluminum
separately Cover Nylon
Dry weight: Length 1 1,0 kg. (2.20 lbs.)
Bowl length options for (Approximate) Length 2 1,2 kg. (2.63 lbs.)
design flexibility Length 3 1,3 kg. (2.87 lbs.)
Easy element changes Length 4 1,5 kg. (3.31 lbs.)
Bypass valve prevents
excessive pressure drop
and prevents element
collapse and release of
retained contaminant's OFRT100 * C * * * G* A** T
back into hydraulic
system 1 2 3 4 5 6 7 8 9

Designed to comply with


ISO standards 1 Filter Series - OFRT 100 5Breather Options G8 - 1.3125 - 12 UN SAE -
16 Straight thread
S - No breather G9 - 1.625 - 12 UN SAE -
2 Assembly Length C - 10 m breather
OFRT 100 Series 20 Straight thread
mm (inch) M - 40 m breather
Filter and Element 1- 225 (8.8) 8
6 Fluid Cleanliness Rating
Model Code 2- 269 (10.6) Seal Material
Target fluid
3- 319 (12.6) A - Buna-N
4- 419 (16.5) Code cleanliness level
Sample model code: V - Viton-A
Length given does not include diffuser A06 18/16/14 or better
OFRT1001COSAG7A06T 7Port Options A10 20/18/15 or better
3 Bypass Options G1 - G 3/4 to ISO 228
C - Bypass set at 1.7 bar G2 - G 1 to ISO 228 9 Indicator Options
(25 psi) cracking pressure G3 - G 1-1/4 to ISO 228
G4 - 3/4 NPT T - No Indicator (plug), No
4 Diffuser Options Connector
G5 - 1" NPT
O - No diffuser G6 - 1-1/4" NPT
D - With diffuser G7 - 1.0625 - 12 UN SAE -
12 Straight thread

Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 51
In-tank Filters Flows to 105 L/min (27.7 USgpm)
Pressures to 10 bar (150 psi)
OFRT100 Series

FT100 * A** *

1 2 3 4

Element model code 1 Filter Element - FT 100 3 Fluid Cleanliness Rating 4 Seal Material
Target fluid A - Buna-N
Sample model code: 2 Element Length Code cleanliness level V - Viton-A
mm (inch) A06 18/16/14 or better
FT1002A06A
1- 128 (5.0) A10 20/18/15 or better
2- 172 (6.8)
3- 222 (8.7)
4- 322 (12.7)

Housing Dimensions
mm (inch)
71 (2.80)
Inlet connection A

Without air 116


breather (4.57)

With air
breather

54 (2.13) Holes required on tank


9 (0.35) R 11,5 (0.45) 88/90
(3.46/3.54)
108 (4.25)
20 (0.79)
only for air
68 (2.68)
breather
26 (1.02)
116
12 (4.57)
(0.47) 32 (1.26)
40 (1.57)
97
(3.82)
M8 2 places

86 G indicator 59 (2.32)
(3.39) connection

111 (4.37)

77 (3.03) filter
element
length
H
80
(3.15)

72 (2.83)

80 (3.15)

With Without
Diffuser Diffuser

Items not in bold are non-standard and may have a longer lead time
52 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
In-tank Filters Flows to 105 L/min (27.7 USgpm)
Pressures to 10 bar (150 psi)
OFRT100 Series
Flow Data

Element Flow Data

OFRT100 Length 1 OFRT100 Length 2


Flow rate - USgpm Flow rate - USgpm
0 7 13 20 26 33 40 0 7 13 20 26 33 40

Pressure drop - psid

Pressure drop - psid


Pressure drop - bar

Pressure drop - bar


1,00 15.0 1,00 15.0
06 06
0,75 10.5 0,75 10.5
10
0,50 7.0 0,50 10 7.0
0,25 3.5 0,25 3.5
0,00 0.0 0,00 0.0
0 25 50 75 100 125 150 0 25 50 75 100 125 150
Flow rate - L/min Flow rate - L/min

OFRT100 Length 3 OFRT100 Length 4


Flow rate - USgpm Flow rate - USgpm
0 13 26 40 53 66 79 0 13 26 40 53 66 79
Pressure drop - psid

Pressure drop - psid


Pressure drop - bar

Pressure drop - bar


1,00 15.0 1,00 06 15.0
06 10
10
0,75 10.5 0,75 10.5
0,50 7.0 0,50 7.0
0,25 3.5 0,25 3.5
0,00 0.0 0,00 0.0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Flow rate - L/min Flow rate - L/min

Housing/Bypass Valve Flow Data


Housing Bypass Valve
Based on mineral oil with density of 0,86 kg/dm 3 .
P varies proportionally to density.
Flow Rate - USgpm Flow Rate - USgpm
0 10.6 21.1 31.7 42.3 52.8 63.4 0 6.6 13.2 19.8 26.4 33.0
0,20 2.9 3,00 43.5
3/4
Pressure drop - bar

Pressure drop - psid

Pressure drop - bar

Pressure drop - psid


0,15 2.2 2,25 32.6
1
0,10 1.5 1,50 21.8

0,05 0.7 0,75 10.9


1-1/4
0,00 0.0 0,00 0.0
0 40 80 120 160 200 240 0 25 50 75 100 125
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : OFRT1001COSAG7A06T - Filter assembly having filter element with micron rating code '06'
at 25 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.01 x 0.8/0.9 + 0.3 x 46/32 x 0.8/0.9
= 0.008 + 0.38
= 0.49 bar
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 53
In-tank Filters Flows to 105 L/min (27.7 USgpm)
Pressures to 10 bar (150 psi)
OFRT250 Series

Features and Benefits DESIGN SPECIFICATIONS

High efficiency filter Rated flow: Length 1 115 L/min (30.4 USgpm)
Length 2 160 L/min (42.3 USgpm)
elements with superior Length 3 205 L/min (54.2 USgpm)
dirt-holding capacity Length 4 360 L/min (95.1 USgpm)
designed for return lines Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water
and installed semi- and water-in-oil fluids, Optional seals available for phosphate esters.
immersed in a reservoir Temp range: -25C to +110C (-13F to +230F)
Excellent pressure drop Pressure rating: Operating 10 bar (150 psi)
characteristics Fatigue 10 bar (150 psi)
Indicators ordered Material: Head Die Cast Aluminum
separately Cover Aluminum
Dry weight: Length 1 3,9 kg. (8.60 lbs.)
Bowl length options for (Approximate) Length 2 4,1 kg. (9.04 lbs.)
design flexibility Length 3 4,6 kg. (10.14 lbs.)
Easy element changes Length 4 4,8 kg. (10.58 lbs.)
Bypass valve prevents
excessive pressure drop
and prevents element OFRT250 * C * S * ** A** T
collapse and release of
retained contaminants 1 2 3 4 5 6 7 8 9
back into hydraulic
system
1 Filter Series - OFRT 250 5
Breather Options F1 - 1-1/2" SAE Flange Code
Designed to comply with 61 with metric bolts
ISO standards S - No breather F2 - 1-1/2" and 1-1/4" in SAE
2 Assembly Length
6 Flange Code 61 with
mm (inch) Seal Material
metric bolts (dual)
OFRT 250 Series 1- 285 (11.2) A - Buna-N F3 - 1-1/2 in SAE Flange
Filter and Element 2- 335 (13.2) V - Viton-A Code 61 with UNC bolts
3- 405 (15.9) F4 - 1-1/2 in and 1-1/4 in SAE
Model Code 4- 610 (24.0) 7
Port Options Flange Code 61 with UNC
Length given does not include diffuser (G-threaded, F-flanged) bolts
Sample model code: G1 - G1-1/2 to ISO 228
3 Bypass Options
OFRT2501COSAG7A06T G2 - G - 1-1/2 and G 1-1/4 to 8 Fluid Cleanliness Rating
C - Bypass set at 1.7 bar ISO 228 (dual) Target fluid
(25 psi) cracking pressure G4 - 1-1/2" NPT Code cleanliness level
G5 - 1-1/2 " and 1-1/4"
4 Diffuser Options A06 18/16/14 or better
NPT (dual)
O - No diffuser G7 - 1.875 - 12 UN SAE -24 A10 20/18/15 or better
D - With diffuser Straight thread
G8 - 1.625 - 12 UN SAE - 20 9 Indicator Options
and 1.875 - 12 UN SAE - T - No Indicator (plug),
24 Straight thread (dual) No Connector

Items not in bold are non-standard and may have a longer lead time
54 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
In-tank Filters Flows to 105 L/min (27.7 USgpm)
Pressures to 10 bar (150 psi)
OFRT250 Series

FT250 * A** *

1 2 3 4

Element model code 1 Filter Element - FT 250 3 Fluid Cleanliness Rating 4 Seal Material
Target fluid A - Buna-N
Sample model code: 2 Element Length Code cleanliness level V - Viton-A
mm (inch) A06 18/16/14 or better
FT2502A06A
1- 175 (6.9) A10 19/17/14 or better
2- 225 (8.9)
3- 295 (11.6)
4- 500 (19.7)

Housing Dimensions
mm (inch)
Single inlet models
150 (5.91) 150 (5.91)

Port B

Port Port
A A 150
150
(5.91) (5.91)

175
(6.89)
11 (0.43)

90 (3.54) 90
(3.54)

110 42 (1.65)
(4.33)

132 (5.20) 12 (0.47)

130 (5.12)

H filter
element
length
90
(3.54)

106 (4.17)

W Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 55
In-tank Filters Flows to 105 L/min (27.7 USgpm)
Pressures to 10 bar (150 psi)
OFRT250 Series
Flow Data

Element Flow Data

OFRT250 Length 1 OFRT250 Length 2


Flow rate - USgpm Flow rate - USgpm
0 13 26 40 53 66 79 0 13 26 40 53 66 79

Pressure drop - psid

Pressure drop - psid


Pressure drop - bar

Pressure drop - bar


1,00 15.0 1,00 15.0
06 06
0,75 10.5 0,75 10.5
10
0,50 7.0 0,50 7.0
10
0,25 3.5 0,25 3.5
0,00 0.0 0,00 0.0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Flow rate - L/min Flow rate - L/min

OFRT250 Length 3 OFRT250 Length 4


Flow rate - USgpm Flow rate - USgpm
0 26 53 79 105 132 159 0 26 53 79 105 132 159
Pressure drop - psid

Pressure drop - psid


Pressure drop - bar

Pressure drop - bar


1,00 15.0 1,00 15.0
06
0,75 10.5 0,75 10.5
06
0,50 10 7.0 0,50 7.0
0,25 3.5 0,25 10 3.5
0,00 0.0 0,00 0.0
0 100 200 300 400 500 600 0 100 200 300 400 500 600
D Flow rate - L/min Flow rate - L/min

Housing/Bypass Valve Flow Data


Housing Bypass Valve
Based on mineral oil with density of 0,86 kg/dm 3.
P varies proportionally to density.
Flow Rate - USgpm Flow Rate - USgpm
0 26.4 52.8 79.3 105.7 132.1 158.5 0 13.2 26.4 39.6 52.8 66.0
0,20 2.9 3,00 43.5
1-1/2
Pressure drop - psid

Pressure drop - bar


Pressure drop - bar

Pressure drop - psid


0,15 2.2 2,25 32.6

0,10 1.5 1,50 21.8

0,05 0.7 0,75 10.9

0,00 0.0 0,00 0.0


0 100 200 300 400 500 600 0 50 100 150 200 250
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : OFRT2501COSAG7A06T - Filter assembly having filter element with micron rating code '06'
at 100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.01 x 0.8/0.9 + 0.3 x 46/32 x 0.8/0.9
= 0.008 + 0.38
= 0.49 bar
56 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
In-tank Filters Flows to 480 L/min (126.8 USgpm)
Pressures to 10 bar (150 psi)
OFRT630 Series

Features and Benefits DESIGN SPECIFICATIONS

High efficiency filter Rated flow: Length 1 320 L/min (84.5 USgpm)
Length 2 400 L/min (105.7 USgpm)
elements with superior Length 3 440 L/min (116.2 USgpm)
dirt-holding capacity Length 4 480 L/min (126.8 USgpm)
designed for return lines Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water
and installed semi- and water-in-oil fluids, Optional seals available for phosphate esters.
immersed in a reservoir Temp range: -25C to 110C (-13F to 230F)
Excellent pressure drop Pressure rating: Operating 10 bar (150 psi)
characteristics Fatigue 10 bar (150 psi)
Indicators ordered Material: Head Die Cast Aluminum
separately Cover Aluminum
Dry weight: Length 1 8,2 kg. (18.1 lbs.)
Bowl length options for (Approximate) Length 2 8,7 kg. (19.2 lbs.)
design flexibility Length 3 9,0 kg. (19.8 lbs.)
Easy element changes Length 4 9,5 kg. (20.9 lbs.)
Bypass valve prevents
excessive pressure drop
and prevents element
collapse and release of
retained contaminant's OFRT630 * C * S * F* A** T
back into hydraulic
system 1 2 3 4 5 6 7 8 9
Designed to comply with
ISO standards 1 5 8
Filter Series - OFRT 630 Breather Options Fluid Cleanliness Rating
S - No breather Target fluid
2 Assembly Length Code cleanliness level
OFRT 630 Series mm (inch) 6 Seal Material A06 18/16/14 or better
Filter and Element 1- 400 (15.7) A - Buna-N A10 20/18/15 or better
Model Code 2- 480 (18.8) V - Viton-A
3- 580 (22.8) 9 Indicator Options
4- 670 (26.4) 7Port Options
Sample model code: T - No Indicator (plug), No
Length given does not include diffuser F1 - 2-1/2 in SAE Flange Code
OFRT6301COSAF3A06T Connector
61 with metric bolts
3 Bypass Options F2 - 2 in and 2-1/2 in SAE
C - Bypass set at 1.7 bar Flange Code 61 with
(25 psi) cracking pressure metric bolts (dual)
F3 - 2-1/2 in SAE Flange Code
4 Diffuser Options 61 with UNC bolts
O - No diffuser F4 - 2 in and 2-1/2 in SAE
D - With diffuser Flange Code 61 with
UNC bolts

Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 57
In-tank Filters Flows to 480 L/min (126.8 USgpm)
Pressures to 10 bar (150 psi)
OFRT630 Series

FT630 * A** *

1 2 3 4

Element model code 1 Filter Element - FT 630 3


Fluid Cleanliness Rating 4 Seal Material
Target fluid A - Buna-N
Sample model code: 2 Element Length Code cleanliness level V - Viton-A
FT6302A06A mm (inch) A06 18/16/14 or better
1- 260 (10.2) A10 19/17/14 or better
2- 340 (13.4)
3- 440 (17.3)
4- 530 (20.9)

Housing
D Dimensions
mm (inch)

182 (7.17) Port A Holes required


215 on tank

Port B (8.46)

M10
182
(7.17)

215
(8.46) 11 (0.43)

166,5/167,0 (6.56/6.57) 90

110
110 (4.33) (4.33)
E
140 55 (2.17)
(5.51) D

C
G
165 (6.50)
14
163 (6.42) (0,55)
H
filter
element
length
110
(4.33)

126 (4.96)

With Without
Diffuser Diffuser

Items not in bold are non-standard and may have a longer lead time
58 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
In-tank Filters Flows to 480 L/min (126.8 USgpm)
Pressures to 10 bar (150 psi)
OFRT630 Series
Flow Data

Element Flow Data

OFRT630 Length 1 OFRT630 Length 2


Flow Rate - USgpm Flow Rate - USgpm
0 26 53 79 106 132 159 0 26 53 79 106 132 159

Pressure drop - psid

Pressure drop - psid


Pressure drop - bar

Pressure drop - bar


1,00 15.0 1,00 15.0
06
06
0,75 10.5 0,75 10.5
10
0,50 7.0 0,50 10 7.0
0,25 3.5 0,25 3.5
0,00 0.0 0,00 0.0
0 100 200 300 400 500 600 0 100 200 300 400 500 600
Flow Rate - L/min Flow Rate - L/min

OFRT630 Length 3 OFRT630 Length 4


Flow Rate - USgpm Flow Rate - USgpm
0 53 106 159 211 264 317 Pressure drop - psid 0 53 106 159 211 264 317

Pressure drop - psid


Pressure drop - bar

Pressure drop - bar


1,00 15.0 1,00 15.0
06 06
0,75 10 10.5 0,75 10.5
10
0,50 7.0 0,50 7.0
0,25 3.5 0,25 3.5
0,00 0.0 0,00 0.0
0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200
Flow Rate - L/min Flow Rate - L/min

Housing/Bypass Valve Flow Data

Housing Bypass Valve


Based on mineral oil with density of 0,86 kg/dm 3.
P varies proportionally to density.
Flow Rate - USgpm Flow Rate - USgpm
0 52.8 105.7 158.5 211.3 264.2 317.0 0 26.4 52.8 79.3 105.7 132.1
0,20 2.9 3.00 43.5
2-1/2
Pressure drop - psid

Pressure drop - psid


Pressure drop - bar

Pressure drop - bar

0,15 2.2 2,25 32.6

0,10 1.5 1,50 21.8

0,05 0.7 0,75 10.9

0,00 0.0 0,00 0.0


0 200 400 600 800 1000 1200 0 100 200 300 400 500
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : OFRT6301COSAF3A06T - Filter assembly having filter element with micron rating code '06'
at 300 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.02 x 0.8/0.9 + 0.6 x 46/32 x 0.8/0.9
= 0.017 + 0.76
= 0.77 bar

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 59


In-tank Filters Flows to 1,500 L/min (396.3 USgpm)
Pressures to 10 bar (150 psi)
OFRT850 Series

Features and Benefits DESIGN SPECIFICATIONS

High efficiency filter Rated flow: Length 1 650 L/min (171.7 USgpm)
Length 2 1000 L/min (264.2 USgpm)
elements with superior Length 3 1200 L/min (317.0 USgpm)
dirt-holding capacity Length 4 1500 L/min (396.3 USgpm)
designed for return lines Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water
and installed semi- and water-in-oil fluids, optional seals available for phosphate esters.
immersed or totally Temp range: -25C to 110C (-13F to 230F)
immersed in a reservoir
Pressure rating: Operating 10 bar (150 psi)
Excellent pressure drop Fatigue 10 bar (150 psi)
characteristics Material: Head Die Cast Aluminum
Indicators ordered Cover Steel
separately Dry weight: Length 1 30 kg. (66.14 lbs.)
(Approximate) Length 2 34 kg. (74.96 lbs.)
Bowl length options for Length 3 37 kg. (81.57 lbs.)
design flexibility Length 4 41 kg. (90.39 lbs.)
Easy element changes
Bypass valve prevents
excessive pressure drop
and prevents element
collapse and release of
retained contaminant's OFRT850 * C * S * F3 A** T
back into hydraulic
system
1 2 3 4 5 6 7 8 9
Designed to comply with
ISO standards
1 Filter Series - OFRT 850 5
Breather Options 8 Fluid Cleanliness Rating
S - No breather Target fluid
2 Assembly Length Code cleanliness level
OFRT 850 Series mm (inch) 6 Seal Material A06 18/16/14 or better
Filter and Element 1- 572 (22.5) A - Buna-N A10 20/18/15 or better
Model Code 2- 787 (31.0) V - Viton-A
3- 1067 (42.0) 9 Indicator Options
4- 1332 (52.4) 7
Port Options
Sample model code: T - No Indicator (plug), No
F3 - DN 100 PN 10/16 3" Connector
OFRT8501COSAF3A06T 3 Bypass Options SAE/Metric Bolt Holes
C - Bypass set at 1.7 bar
(25 psi) cracking pressure
4 Diffuser Options
O - No diffuser
D - With diffuser

60 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


In-tank Filters Flows to 1,500 L/min (396.3 USgpm)
Pressures to 10 bar (150 psi)
OFRT850 Series

FT850 * A** *

1 2 3 4

Element model code 1 Filter Element - FT 850 3 Fluid Cleanliness Rating 4 Seal Material
Target fluid A - Buna-N
Sample model code: 2 Element Length Code cleanliness level V - Viton-A
mm (inch) A06 18/16/14 or better
FT8502A06A
1- 388 (15.2) A10 19/17/14 or better
2- 603 (23.7)
3- 883 (34.7)
4- 1148 (45.2)

Housing Dimensions
mm (inch)
Port B

G Port B
320 (12.60)

Port A
210 210
(8.27) 22 30
(8.27)
Port B 45
E
76 (2.99)
D 184
(7.24) 180 (7.09)

C 100
247 (9.72) (3.94)
M10
15 220 (8.66)
H (0.59)
filter
250 (9.84) element
length

250 Holes required


(9.84) on tank
22 30

203 (7.99) 45

251,5/252,0
(9.90/9.92)

295 (11.61)
M12

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 61


In-tank Filters Flows to 1,500 L/min (396.3 USgpm)
Pressures to 10 bar (150 psi)
OFRT850 Series
Flow Data

Element Flow Data

OFRT850 Length 1 OFRT850 Length 2


Flow Rate - USgpm Flow Rate - USgpm
0 66 132 198 264 330 396 0 79 159 238 317 396 476

Pressure drop - psid

Pressure drop - psid


Pressure drop - bar

Pressure drop - bar


1,00 15.0 1,00 15.0
06
0,75 10.5 0,75 06 10.5
0,50 10 7.0 0,50 7.0
10
0,25 3.5 0,25 3.5
0,00 0.0 0,00 0.0
0 250 500 750 1000 1250 1500 0 300 600 900 1200 1500 1800
Flow Rate - L/min Flow Rate - L/min
OFRT850 Length 3 OFRT850 Length 4
Flow Rate - USgpm Flow Rate - USgpm
0 93 185 277 370 462 555 0 93 185 277 370 462 555
Pressure drop - psid

Pressure drop - psid


Pressure drop - bar

Pressure drop - bar


1,00 15.0 1,00 15.0
0,75 10.5 0,75 10.5
06
06
0,50 7.0 0,50 7.0
10
0,25 3.5 0,25 10 3.5
0,00 0.0 0,00 0.0
0 350 700 1050 1400 1750 2100 0 350 700 1050 1400 1750 2100
Flow Rate - L/min Flow Rate - L/min

Housing/Bypass Valve Flow Data


Housing Bypass Valve
Based on mineral oil with density of 0,86 kg/dm 3 .
P varies proportionally to density.
Flow Rate - USgpm Flow Rate - USgpm
0 92.5 184.9 277.4 369.8 462.3 554.8 0 52.8 105.7 158.5 211.3 264.2
0,20 2.9 3.00 43.5
4
Pressure drop - psid

Pressure drop - psid


Pressure drop - bar

Pressure drop - bar

0,15 2.2 2,25 32.6

0,10 1.5 1,50 21.8

0,05 0.7 0,75 10.9

0,00 0.0 0,00 0.0


0 350 700 1050 1400 1750 2100 0 200 400 600 800 1000
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : OFRT8501COSAF3A06T - Filter assembly having filter element with micron rating code '06'
at 500 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.02 x 0.8/0.9 + 0.3 x 46/32 x 0.8/0.9
= 0.017 + 0.38
= 0.39 bar

62 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


In-tank Filters Flows to 850 L/min (225 USgpm)
Pressures to 10 bar (145 psi)
ORFM Series

Features and Benefits DESIGN SPECIFICATIONS

Beta Ratio: x(c) = 1000 Rated flow: Length 1 30 L/min (8 USgpm)


to ISO 16889 Length 2 75 L/min (20 USgpm)
Length 3 90 L/min (24 USgpm)
Ideal for mobile Length 4 165 L/min (43 USgpm)
applications due to Length 5 330 L/Min (87 USgpm)
lightweight and compact Length 6 660 L/min (174 USgpm)
design Length 7 850 L/min (225 USgpm)
Fluid compatibility: Compatible with all petroleum oil and synthetic fluids rated for use with
Clogging indication fluoro-rubber or ethylene propylene seals.
cavities are standard
Temp range: -30C to +121C (-22F to +250F)
Housing and lid are Pressure rating: Operating 10 bar (145 psi)
constructed of durable Fatigue 10 bar (145 psi)
plastic polyamide or
Material: Length 1 Head, Bowl, Lid Plastic
aluminum Length 2/3/4 Head Aluminum
Aluminum alloy does not Bowl, Lid Plastic
require anodizing for Length 5/6/7 Head, Bowl, Lid Aluminum
water-based fluids Dry weight: (Approximate) Length 1 .32 kg. (0.7 lbs)
Lengths 2/3/4 have Length 2 .59 kg. (1.3 lbs)
Length 3 .41 kg. (0.9 lbs)
filter bowls that are Length 4 .68 kg. (1.5 lbs)
removed to change the Length 5 3.1 kg. (6.8 lbs)
element and also serve as Length 6 6.0 kg. (13.2 lbs)
a contamination basket Length 7 6.5 kg. (14.3 lbs)
Lengths 1/5/6/7 have filter
elements that have a ORFM 1 ** * * * * * ** *
separate, reusable
contamination basket 1 2 3 4 5 6 7 8 9 10

ORFM Series 1 JN - No Indicator (plug), 6 Seal Material


Filter Series- ORFM
No Connector
Filter and Element B - Buna-N
MB - Electrical 1 bar (15 psi),
Model Code 2 Element Collapse Rating Brad Harrison V - Viton-A
1 - 10 bar (145 psi) Low Collapse MJ - Electrical 1 bar (15 psi),
7 Assembly Length
Sample model code: Hirschmann w 24 volt light
3 Port Options MK - Electrical 1 bar (15 psi), mm (inch)
ORFM1SA2LNB1C05X Hirschmann w 115 volt light 1 - 156 (6.2)
SA - NPT 1/2" length 1 only
ML - Electrical 1 bar (15 psi), 2 - 205 (8.1)
SB - SAE-16 (1" tube) 3 - 246 (9.6)
Hirschmann w 230 volt light
length 2 & 4 only 4 - 289 (11.4)
MH -Electrical 1 bar (15 psi),
SC - SAE-12 (3/4" tube) 5 - 270 (10.6)
Hirschmann
length 3 only RB - Electrical 2 bar (30 psi), Brad 6 - 426 (16.8)
SD - SAE Flange (code 61) Harrison 7 - 507 (19.9)
(1" tube) length 5 only RJ - Electrical 2 bar (30 psi),
SE - SAE-24 (1-1/2" tube) 8 Element Construction
Hirschmann w 24 volt light
length 5 only RK - Electrical 2 bar (30 psi), C - Standard Construction
SF - SAE Flange (code 61) Hirschmann w 115 volt light X - no element
(2" tube) length 6 & 7 only RL - Electrical2 bar (30 psi),
Hirschmann w 230 volt light 9 Fluid Cleanliness Rating
4 Valve Options RH - Electrical 2 bar (30 psi), Target fluid
0 - No Bypass* Hirschmann Code cleanliness level
1 - Bypass set at 25 psi UB - Electrical 4.9 bar (70 psi), 03 16/14/12 or better
Brad Harrison
(1.7 bar) cracking pressure 05 18/16/14 or better
UJ - Electrical 4.9 bar (70 psi),
2 - Bypass set at 43 psi 10 20/18/15 or better
Hirschmann w 24 volt light
(3 bar) cracking pressure UK - Electrical 4.9 bar (70 psi), 20 22/19/16 or better
3 - Bypass set at 87 psi Hirschmann w 115 volt light
(6 bar) cracking pressure XX no element
UL - Electrical 4.9 (70 psi),
Hirschmann w 230 volt light
5 Indicator Options** 10 Diffusor
UH - Electrical 4.9 bar (70 psi),
AN - Visual 4.9 bar (70 psi), Hirschmann D - Diffusor
No Connector GA - Gauge 0-4 Bar (0-60 psi). X - No diffusor
KN - Visual 1 bar (15 psi), Use with valve option 1 * For use with external bypass check valve
No Connector GB - Gauge 0-10 Bar (0-160 psi). (6 bar) 87 psi maximum.
LN - Visual 2 bar (30 psi), Use with valve options ** For indicator options, refer to Static
No Connector 2 & 3 Indicators on page 150.
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 63
In-tank Filters Flows to 850 L/min (225 USgpm)
Pressures to 10 bar (145 psi)
ORFM Series
V209 1 * * C **

1 2 3 4 5 6

V209 Element 1 Filter Element - V209 3 Seal Material 5 Element Construction


model code B - Buna-N C - Standard Construction
2 Valve Options V - Viton-A
Sample model code: 6 Fluid Cleanliness Rating
0 - No Bypass*
4 Assembly Length Target fluid
V2091B3C10 1 - Bypass set at (1.7 bar)
25 psi cracking pressure mm (inch) Code cleanliness level
2 - Bypass set at (3 bar) 1 - 156 (6.1) 03 16/14/12 or better
43 psi cracking pressure 2 - 204.8 (8.1) 05 18/16/14 or better
3 - Bypass set at (6 bar) 3 - 246 (9.5) 10 20/18/15 or better
87 psi cracking pressure 4 - 288.8 (11.3)
Housing Dimensions 5 - 270 (10.6) 20 22/19/16 or better
mm (inch) 6- 426 (16.8)
7- 507 (19.9)
Clearance Required Clearance Required C Clearance Required
for Element Removal for Element Removal for Element Removal
Length 1 Length 2 Length 4 Length 3
90 Indicator Port 145 228 200
(3.54) G 1/2 (5.70) (8.98) (7.87)
142
(5.59) Indicator Port
G 1/8

Length 3
Length 1 75
70 (2.85)
(2.76) 31
Length 1 34 (1.22)3
27 (1.34)
(1.06)
Indicator
Port
G 1/8

Length 1 Length 3
86 171
(3.39) Length 2
(6.73)
204.8
(8.06)

Length 4
288.8
(11.37)
18
(0.71)
smooth outlet
Length 1
60 Hose Barb
(2.36) 25
(1.00)
32
Length 1 ( 1.26) 107
(4.21)
10
( 0.39) L Length 5 Length 6 & 7
Length 2 & 4 Length 3 124 167
60 73.4 62 (4.88) (6.57)
( 2.36) (2.89) (2.24)
43 Length
(1.693) 2&4
11
(0.47)
Length 5
Length 12
5 3 (0.47)
( 0.20) 8.5
Length Length (0.34) Length 6 & 7
2&4 3 13.5
112 90 (0.53)
78 Length 5 Length 6 & 7
(4.41) (3.54) 177 220
(3.07) (6.97) (8.66)

64 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


In-tank Filters Flows to 850 L/min (225 USgpm)
Pressures to 10 bar (145 psi)
ORFM Series

Housing Dimensions Clearance Required Clearance for Required


for Element Removal Element Removal
mm (inch)
Length 5 Length 6 Length 7
265 340 420
(10.43) (13.39) (16.54)
200
155 (7.87)
(6.10)
Indicator Indicator
Port Port
G 1/2 G 1/2"
98 48 126
(3.86) (4.96) 55
(1.88) (2.165)

Length 5
172 Length 6
(6.77) 300
(11.81)

Length 7
3.81
(15.00)

Threaded
Outlet
G 2
122
(4.80) Threaded Outlet
G 2 1/2
165
( 6.50)

ORFM Clogging Indicator


Locations
LENGTH LOCATION OF CLOGGING INDICATOR

1 Clogging Indicator on top centerline


2/4 Clogging Indicator Left Back 90 to inlet
3 Clogging Indicator Left Front 45 to inlet
5 Clogging Indicator Left Side 90 to inlet
6/7 Clogging Indicator Left Side 90 to inlet

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 65


In-tank Filters
ORFM Series
Flow Data

Element Flow Data

ORFM Filter Elements

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 20

C -pak 1 0.068 (3.748) 0.044 (2.407) 0.027 (1.470) 0.015 (0.808)


2 0.022 (1.208) 0.014 (0.779) 0.008 (0.444) 0.004 (0.240)
3 0.015 (0.815) 0.010 (0.553) 0.007 (0.369) 0.003 (0.175)
4 0.011 (0.615) 0.008 (0.429) 0.004 (0.245) 0.002 (0.132)
5 0.004 (0.231) 0.003 (0.149) 0.004 (0.092) 0.001 (0.065)
6 0.002 (0.105) 0.001 (0.066) 0.001 (0.042) 0.001 (0.028)
7 0.001 (0.081) 0.001 (0.054) 0.001 (0.036) 0.001 (0.023)
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

66 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


In-tank Filters Flows to 1,320 L/min (349 USgpm)
Pressures to 10 bar (145 psi)
ORFM Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9
Housing/Bypass Valve
Flow Data

ORFM Length 1 Housing ORFM Length 1 Bypass

Flow Rate - USgpm Flow Rate - USgpm


0 1 2 3 4 5 6 7 8 0 5 10 15 20 25 30
25 100
1,6

Pressure drop - bar


Pressure drop - bar

6,0

Pressure drop - psid


Pressure drop - psid
20 80
1,2
15 4,0 60
0,8
10 40
2,0
0,4 20
5
0 0,0 0
0
0 5 10 15 20 25 30 0 10 20 30 40 50 60 70 80 90 100 110 120
Flow Rate - L/min Flow Rate - L/min

ORFM Length 2 & 4 Housing ORFM Length 2/4 Bypass


Flow Rate - USgpm Flow Rate - USgpm
0 10 20 30 40 50 0.0 5 10 15 20 25 30 35 40
0,3 5 5.0
Pressure drop - bar

,25 69
Pressure drop - psid

Pressure drop - psid


64
Pressure drop - bar

0,2
3
,15 4.0 59
0,1 2 54
1 49
,05
3.0 44
0,0 0
0 40 80 120 160 39
Flow Rate - L/min 34
2.0 29
0 20 40 60 80 100.0 120.0 140.0 160.0
Flow Rate - L/min

ORFM Length 3 Housing ORFM Length 3 Bypass


Flow Rate - USgpm Flow Rate - USgpm
0 10 20 30 40 50
0 10 20 30 45 5.0
7 71.5
Pressure drop - bar
Pressure drop - bar

67.5
Pressure drop - psid

6
Pressure drop - psid

0,3 5 63.5
4 59.5
0,2 4.0
3 55.5
2 51.5
0,1
1 47.5
0 0 3.0 43.5
0 38 76 114 170 0 25 50 75 100 125 150 175 200

Flow Rate - L/min Flow Rate - L/min

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 67


In-tank Filters Flows to 1,320 L/min (349 USgpm)
Pressures to 10 bar (145 psi)
ORFM Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9
Housing/Bypass Valve
Flow Data

ORFM Length 5 Housing ORFM Length 5 Bypass


Flow Rate - USgpm
Flow Rate - USgpm
0.0 10.0 20.0 30.0 40.0 50.0
0 25 50 75 100 125
0,3 5 5.0 71.5
Pressure drop - bar

,25

Pressure drop - psid


4 67.5

Pressure drop - psid


Pressure drop - bar
0,2
3 63.5
,15
2 59.5
0,1 4.0
1 55.5
,05
0,0 51.5
0
0 100 200 300 400 47.5
Flow Rate - L/min
3.0 43.5
0 25 50 75 100 125 150 175 200

ORFM Length 6 & 7 Housing ORFM Length 6 & 7 Bypass Flow Rate - L/min

Flow Rate - USgpm Flow Rate - USgpm


0 40 80 120 160 250 0 20 40 60 80 100
0,3 5 3.7 53.0
Pressure drop - bar
Pressure drop - bar

3.6 51.0

Pressure drop - psid


,25
Pressure drop - psid

4 3.5
0,2 3.4 49.0
3 3.3 47.0
,15 3.2
2 3.1 45.0
0,1
3.0 43.0
,05 1 2.9
2.8 41.0
0,0 0
0 100 200 300 400 500 600 700 800 0 50 100 150 200 250 300 350 400
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : ORFM1SA2LNB1C05X - Filter assembly having '1' length filter element with micron rating
code '05' at 25 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.6 x 0.8/0.9 + 25 x 0.044 x 46/32 x 0.8/0.9
= 0.520 + 1.39
= 1.91 bar

68 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


In-tank Filters Flows to 1,300 L/min (343 USgpm)
Pressures to 25 bar (360PSI)
ORF 1300

Features and Benefits DESIGN SPECIFICATIONS

Beta Ratio: x(c) = 1000 Rated flow: 1300 L/min (343 USgpm)
to ISO 16889 Fluid compatibility: Compatible with all petroleum oils and synthetic fluids rated for use with
Fluoro-Rubber or Ethylene Propylene seals.
Non-welded housing
design reduces stress Temp range: -30C to + 121C (-22F to 250F)
concentrations prevents Pressure rating: Operating 25 bar (360 psi)
fatigue failure Fatigue 25 bar (360 psi)
O-ring seals are used to Material: Housing, Lid, Transfer Valve: Ductile Iron
provide positive, reliable Dry weight: 43kg (94.8 lbs)
sealing (Approximate)
Bolt-on lid requires
minimal clearance for
removal
Reusable contamination
basket prevents loss of
retained contaminants into
the reservoir during
element replacement
ORF 1 F * ** * 1 * **
Clogging indicators can
be serviced without
1 2 3 4 5 6 7 8 9
interruption of the
hydraulic system
1 Filter Series - ORF MK - Electrical 1 bar (15 psi), UH - Electrical 4.9 bar
Single piece casting
Hirschmann w 115 volt (70 psi), Hirschmann
provides rigidity for inline light GA - Gauge 0-4 Bar (0-60 psi).
2 Element Collapse Rating
or in-tank mounting ML - Electrical 1 bar (15 psi), Use with valve option 1
1 - 17 bar (250 psi) Low Hirschmann w 230 volt GB - Gauge 0-10 Bar (0-160
ORF 1300 Series Collapse light psi).
Filter and Element 3
MH - Electrical 1 bar (15 psi), Use with valve option 2
Port Options Hirschmann
Model Code
F - 4" SAE Flange, Code 61 RB - Electrical 2 bar (30 psi), 6 Seal Material
Brad Harrison B - Buna-N
Sample model code: 4 Valve Options RJ - Electrical 2 bar (30 psi), V - Viton-A
ORF1F2JNB1C05 0 - Non-Bypass Hirschmann w 24 volt
1 - Bypass set at 1.7 bar light 7 Assembly Length
(25 psi) cracking pressure RK - Electrical 2 bar (30 psi), mm (inch)
2 - Bypass set at 2.9 bar Hirschmann w 115 volt 1 - 584 (23.0)
(43 psi) cracking pressure light
3 - Bypass set at 5.9 bar RL - Electrical 2 bar (30 psi), 8 Element Construction
(87 psi) cracking pressure Hirschmann w 230 volt
C - Standard Construction
light
5 Indicator Options*
X - no element
RH - Electrical 2 bar (30 psi),
AN - Visual 4.9 bar (70 psi), Hirschmann 9 Fluid Cleanliness Rating
No Connector UB - Electrical 4.9 bar
Target fluid
KN - Visual 1 bar (15 psi), (70 psi), Brad Harrison Code cleanliness level
No Connector UJ - Electrical 4.9 bar
(70 psi), Hirschmann 03 16/14/12 or better
LN - Visual 2 bar (30 psi),
No Connector w 24 volt light 05 18/16/14 or better
JN - No Indicator (plug), UK - Electrical 4.9 bar 10 20/18/15 or better
No Connector (70psi), Hirschmann 20 22/19/16 or better
MB - Electrical 1 bar (15 psi), w 115 volt light XX no element
Brad Harrison UL - Electrical 4.9 bar (70 psi),
MJ - Electrical 1 bar (15 psi), Hirschmann w 230 volt
Hirschmann w 24 volt light
light * For indicator options, refer
to Static Indicators on page

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 69


In-tank Filters Flows to 1,300 L/min (343 USgpm)
Pressures to 25 bar (360PSI)
ORF 1300

V209 1 * 8 C **

1 2 3 4 5 6

Element model code 1 Filter element - V209 4 Element Length 6 Fluid cleanliness rating
mm (inch) Target fluid
Sample model code: 2 Element Collapse Rating 8 - 253 (9.96) Code cleanliness level
V2091B8C10 1 - 17 bar (250 psi) Low 03 16/14/12 or better
5 Element construction
Collapse 05 18/16/14 or better
C - Standard Construction 10 20/18/15 or better
3 Seal material
20 22/19/16 or better
B - Buna-N
V - Viton-A

Housing Dimensions
mm (inch)

Mounting Pattern
460
(18.11)
Clearance required
for element changeout Indicator Port 290
G 1/2 (11.42) 18
(0.71)

253
(9.96) 208
(8.19)

584
(22.99)

121
(4.76)

255
(10.04)

70 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


In-tank Filters Flows to 1,300 L/min (343 USgpm
Pressures to 25 bar (360PSI)
ORF 1300
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9

ORF1300 Filter Elements Flow Data

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 20

C -pak 1 0.001 (0.048) 0.001 (0.037) 0.001 (0.034) 0.001 (0.019)


Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Housing Bypass Valve


Flow Rate - USgpm Flow Rate - USgpm
0 100 200 300 400 0.0 20.0 40.0 60.0 80.0 100.0
2.0

4.8 70.0
0,12

Pressure Drop - psid


Pressure Drop - bar

Pressure Drop - Bar

1.5
Pressure Drop - psi

0,10
4.3
60.0
0,08
1.0 3.8
0,06
50.0
0,04 3.3
0.5
0,02
2.8 40.0
0 0 0 50 100 150 200 250 300 350 400
0 300 600 900 1200 1400
Flow Rate - L/min
Flow Rate - L/min

Sample P Calculation : ORF1F2JNB1C05 - Filter assembly having '1' length filter element with micron rating code
'05' at 200 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.01 x 0.8/0.9 + 200 x 0.001 x 46/32 x 0.8/0.9
= 0.008 + 0.25
= 0.26 bar

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 71


In-tank Filters Flows to 630 L/min (166 USgpm)
Pressures to 10 bar (145 psi)
DRT DIN Series
Filters

Features and Benefits DESIGN SPECIFICATIONS

Beta Ratio: x(c) = 1000 Rated flow: 040 40 L/min (11USgpm)


063 63 L/min (17USgpm)
to ISO 16889 100 100 L/min (26USgpm)
Gauge and electrical 160 160 L/min (42USgpm)
switch options available to 250 250 L/min (66USgpm)
monitor element loading 400 400 L/min (106USgpm)
630 630L/min (166USgpm)
In-tank configuration Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
minimizes space Optional seals available for phosphate esters
requirements and Temp range: -10C to + 100C (+14F to +212F)
potential system leakage
Pressure rating: Operating 25 bar (363 psi)
points
Material: Aluminum
High efficiency
Dry weight: 040 1,5 kg (3.3lbs)
replacement elements in 063 1,5 kg (3.3lbs)
standard configurations 100 1,5kg (3.3lbs)
(C-Pak) to meet Target 160 3,8kg (8.4lbs)
Cleanliness Levels 250 3,8kg (8.4lbs)
400 9,0kg (19.8lbs)
630 9,0kg (19.8lbs)

DRT 1 *** ** 4 ** N * * **

1 2 3 4 5 6 7 8 9 10

DRT Series Filter 1Filter Series BE - G 1 1/4 (Length 160 only) 8 Seal Material
BF - G 1 1/2 (Length 250 only)
DRT - DIN In-Tank B - Buna-N
Sample model code: BM - 2 1/2 in SAE Flange
V - Viton-A
2 Code 61 with metric
DRT1100BD4XXNBC06 Element Collapse Rating
bolts (DN 64) (Length 9
1 - Low Collapse Element Construction
400 and 630 only)
C - Standard Construction
3 Nominal Size 5 X - no element
Valve Options
040 - 40 L/min (11USgpm) 4 - Bypass set at 3 bar (50 psi) 10Fluid Cleanliness Rating
063 - 63 L/min (17USgpm) cracking pressure
100 - 100 L/min (26USgpm) Target fluid
160 - 160 L/min (42USgpm) 6 Code cleanliness level
Indicator Options *
250 - 250 L/min (66USgpm) 03 16/14/12 or better
XX - No Indicator
400 - 400 L/min (106USgpm) 06 18/16/14 or better
GB - 0-10 bar (0-145 psi) gauge
630 - 630L/min (166USgpm) 10 20/18/15 or better
RH - Electrical switch
4 Hirschmann 25 22/19/16 or better
Port Size
BB - G 1/2 (Length 040 only) 7
XX no element
Secondary Port
BC - G 3/4 (Length 063 only)
N - No Secondary Port
BD - G 1 (Length 100 only)

* For indicator options, refer to Static Indicators on page 150.

72 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


In-tank Filters Flows to 630 L/min (166 USgpm)
Pressures to 10 bar (145 psi)
DRT DIN Series
Filters

VDT *** * C **

1 2 3 4 5

Element model code 1 Filter Element 3 Seal Material 5 Fluid Cleanliness Rating
VDT - DIN Standard Element B - Buna-N Target fluid
Sample model code: V - Viton-A Code cleanliness level
2 Nominal Size 03 16/14/12 or better
VDT250BC06 4
040 - 40 L/min (11USgpm) Element Construction 06 18/16/14 or better
063 - 63 L/min (17USgpm) C - Standard Construction 10 20/18/15 or better
100 - 100 L/min (26USgpm) 25 22/19/16 or better
160 - 160 L/min (42USgpm)
250 - 250 L/min (66USgpm)
400 - 400 L/min (106USgpm)
630 - 630L/min (166USgpm)
Dimensions DRT 040, 063, 100 Series

Dimensions in mm
72 b1 Minimum Clearance
55 h2
For Element Removal

93
43 34

Inlet
Connection for
indicator
84
h1

138.5

73

Outlet Holes Required on Tank


115 Bolt Circle 90+1
11

M-10

115
138.5

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 73


In-tank Filters Flows to 630 L/min (166 USgpm)
Pressures to 10 bar (145 psi)
DRT DIN Series
Filters

Dimensions DRT 160 and 250 Series

Dimensions in mm
h1 Minimum for
element removal Connection for
indicator
37
106.5
47
Inlet

101 91

Holes Required on Tank 266

185 Bolt Circle 132


140+1

Outlet
M-10 185

187
b1

182

74 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


In-tank Filters Flows to 630 L/min (166 USgpm)
Pressures to 10 bar (145 psi)
DRT DIN Series
Filters
Housing Flow Data

DRT 040, 063, 100 Series Housing Data

H drop:
Flow versus pressure DRT 040/063/100
0.07
32 cSt oil with specific gravity of 0.9
(See page 5 for specific gravity corrections for pressure drop.) 0.06

TYPE INLET PORT b1 h1 h2 0.05

p [bar]
DRT 040 G 1/2 81 122 150
DRT 063 G 3/4 70 206 200 0.04
DRT 100 G1 70 260 290
0.03

0.02

0.01

0.00
0 20 40 60 80 100
Q in l/min

DRT 160 and 250 Series Housing Data

Flow versus pressure drop: DRT 160/250


0.12
32 cSt oil with specific gravity of 0.9
(See page 5 for specific gravity corrections for pressure drop.)
0.10
TYPE INLET PORT b1 h1
0.08
p [bar]

DRT 160 G 1 1/4 141 210


DRT 250 G 1 1/2 105 300
0.06

0.04

0.02

0.00
0 50 100 150 200 250
Q in l/min

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 75


In-tank Filters Flows to 630 L/min (166 USgpm)
Pressures to 10 bar (145 psi)
DRT DIN Series
Filters
Element Flow Data

1 Element size 040 3m 1 Element size 063


0.9 0.9
0.8 0.8
0.7 0.7 3m
p [bar]

0.6 6m p [bar] 0.6


0.5 0.5
0.4 0.4 6m
0.3 10m 0.3
0.2 0.2 10m
25m
0.1 0.1 25m
0 0
0 15 30 45 60 75 0 15 30 45 60 75
flow rate [l/min] flow rate [l/min]

1.5 Element size 100 1.5 Element size 160 Element size 250
3m
3m 1.75
1.25 1.25 1.5
p [bar]

p [bar]

1 1 1.25

p [bar]
0.75 6m 0.75 1 6m
3m
0.75 10m
0.5 0.5 6m
10m 0.5 25m
0.25 0.25 10m
25m 25m 0.25
0 0 0
0 50 100 150 200 0 50 100 150 200 0 100 200 300 400 500 600
flow rate [l/min] flow rate [l/min]
flow rate [l/min]
Element size 400 Element size 630
1.75 2.5 3m
1.5 2
1.25 3m
p [bar]

p [bar]

1 1.5 6m
6m
0.75 1 10m
10m 25m
0.5 25m
0.5
0.25
0 0
0 100 200 300 400 500 600 0 200 400 600 800 1000 1200
flow rate [l/min] flow rate [l/min]

Sample P Calculation : DRT1100BD4XXNBC06 - Filter assembly having filter element with micron rating code '06' at
100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.065 x 0.8/0.9 + 0.3 x 46/32 x 0.8/0.9
= 0.057 + 0.38
= 0.43 bar

76 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


In-tank Filters Flows to 454 L/min (120 USgpm)
Pressures to 7 bar (100 psi)
HF4RT Series

Pop-rivets for
shipping purposes
only. Remove prior
to installation.

Features and Benefits DESIGN SPECIFICATIONS

Beta Ratio: x(c) = 1000 Rated flow: Length 3 189 L/min (50 USgpm)
to ISO 16889 Length 6 379 L/min (100 USgpm)
Length 7 454 L/min (120 USgpm)
Designed to comply with Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids
ANSI specifications and Optional seals available for phosphate esters.
ISO cleanliness standards. Temp range: -30C to 121C (-22F to 250F)
Conforms to HF4 Pressure rating: Operating 7 bar (100 psi)
specifications Fatigue 7 bar (100 psi)
Gauge and electrical Material: Head Aluminum
switch options available to Cover Aluminum
monitor element loading Bowl Carbon Steel
Dry weight: Length 3 4,5 kg. (10.0 lbs.)
In-tank configuration (Approximate) Length 6 6,6 kg. (14.5 lbs.)
minimizes space Length 7 8,4 kg. (18.6 lbs.)
requirements and potential
system leakage points
Optional secondary
port allows filtration of a
second return line without
additional fittings or
filtered fill port
High efficiency
replacement elements in
standard configurations (C-
Pak) to meet Target
Cleanliness Levels. HF4RT 1 ** * ** * ** * * **
Optional extend tube
allows smaller filtration unit
1 2 3 4 5 6 7 8 9 10
to be used where needed
HF4RT Series 1 Filter Series - HF4RT 5 Indicator Options* SZ - 2.50 - 12 UN SAE-32 str.
Filter and Element Thd. (2" tube) - use with
XX - No indicator
Model Code 2 FE Inlet Port
Element Collapse Rating GA - Gauge 0-4 bar (0-60psi)
XX - No Secondary Port
1 - 10 bar (150 psi) Low GB - Gauge 0-10 bar (0-160psi) Note: No secondary port option is available
Sample model code: Collapse MB - Electrical, 15 PSI with the ME inlet port option.
Brad Harrison
HF4RT1SD313XXBC05 3 Port Options RB - Electrical, 30 PSI 8 Seal Material
BC - G11/4 to ISO 228 Brad Harrison
B - Buna-N
ME - 11/2" - SAE 4 bolt Flange MH - Electrical, 15 PSI V - Viton-A
Code 61 (M12 x 1.75) Hirschmann
SD - 1.875 - 12 UN SAE-24 RH - Electrical, 30 PSI 9 Element Construction
str. Thd. (11/2" tube) Hirschmann
C - Standard Construction
FE - 11/2" - SAE 4 bolt Flange 6 X - no element
Code 61 (UNC) Assembly Length
mm (inch)
10 Fluid Cleanliness Rating
4 Valve Options 3 - 378 (14.9)
6 - 584 (23) Target fluid
3 - Bypass set at 1.7 bar 7 - 787 (31) Code cleanliness level
(25 psi)
cracking pressure 03 16/14/12 or better
7 Secondary Port
4 - Bypass set at 3 bar 05 18/16/14 or better
(43 psi) cracking BC - G11/4 to ISO 228 - use 10 20/18/15 or better
pressure with BC Inlet Port
SD - 1.875 - 12 UN SAE-24 20 22/19/16 or better
str. Thd. (11/2" tube) - XX no element
use with SD Inlet Port
* For indicator options, refer to Static Indicators on page 150.

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 77


In-tank Filters Flows to 280 L/min (75 USgpm)
Pressures to 50 bar (725 psi)
HF4RT Series

V405 1 * * C **

1 2 3 4 5 6

V405 Element 1 Filter Element 4 Element Length 6 Fluid Cleanliness Rating


Model Code V405 - For use with HF4RT mm (inch) Target fluid
3 - 229 (9) Code cleanliness level
Sample model code: 2 Element Collapse Rating 6 - 457 (18) 03 16/14/12 or better
1 - 10 bar (150 psi) 7 - 686 (27)
V4051B3C05 05 18/16/14 or better
Low Collapse
5 Element Construction 10 20/18/15 or better
3 Seal Material C - C-Pak (code 03, 05, 10, 20) 20 22/19/16 or better
B - Buna-N
V - Viton-A

Housing Dimensions
mm (inch)
112.2
(4.42)
56.1 M10 or
(2.21) 3/8"-20 thread
4 PL'S
Equally
spaced

112.2
(4.42) 127
(5.0")
158.75
(6.25)

56.1 Reservoir Opening Inlet port


(2.21)
152.2 170.2 3.6
(6.00) (6.70) (0.14)

Secondary 118.5
port
(4.67)

Indicator port
1/8 NPT 53.6
(2.11)
Refer to
Model Code
"ME" port - M12 x 1.75
"FE" port - 1/2 - 13UNC (4 places)
69.8
(2.75) 35.7
(1.41)

Outlet port
Length Connection
3 1" Hose 38.1 (1.5)
6 1 1/2" NPT SAE-4 bolt
124.6 flange code 61
(4.9) 7 1 1/2" NPT
Inlet Flange

78 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


In-tank Filters Flows to 280 L/min (75 USgpm)
Pressures to 50 bar (725 psi)
HF4RT Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9

HF4RT Filter Elements Flow Data

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 20

C -pak 3 0.003 (0.168) 0.003 (0.140) 0.001 (0.078) 0.001 (0.044)


6 0.001 (0.080) 0.001 (0.066) 0.001 (0.037) 0.001 (0.021)
7 0.001 (0.051) 0.001 (0.043) 0.001 (0.024) 0.001 (0.013)
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Housing/Bypass Valve Flow Data

Housing Bypass Valve

Flow Rate - USgpm Flow Rate - USgpm


26 79 26 79
0,8 12 4,5
43 PSI
4,0 4,0
Pressure drop - psid

Pressure drop - psid


Pressure drop - bar

Pressure drop - bar

0,6 3,5
3,0 3,0
0,4 6 25 PSI
2,5
2,0 2,0
0,2
1,5
0
0 100 200 300 400 0 100 200 300 400
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : HF4RT1SD3XX3XXBC05 - Filter assembly having '3' length filter element with micron rating
code '05' at 200 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.15 x 0.8/0.9 + 200 x 0.003 x 46/32 x 0.8/0.9
= 0.130 + 0.76
= 0.89 bar

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 79


In-tank Filters Flows to 380 L/min (100 USgpm)

OSS Suction
Strainers

Features and Benefits DESIGN SPECIFICATIONS

Filters coarse particulate Rated flow: Length 1 30 L/min (8 USgpm)


Length 2 w/1 1/4" NPT 75 L/min (20 USgpm)
to prevent pump damage Length 2 w/1 1/2" NPT 115 L/min (30 USgpm)
Note: Check or verify inlet condition Length 3 190 L/min (50 USgpm)
before use. Length 4 w/1 1/4" NPT 380 L/min (100 USgpm)
Fluid compatibility: Compatible with all petroleum oils and synthetic fluids rated for use with
Fluoro-Rubber or Ethylene Propylene seals.
Temp range: -28 to +100C (-20 to +210F)
Material: Wire Mesh Steel
Fittings Nylon
Dry weight: Length 1 0,2 kg. (0.4 lbs.)
Length 2 0,3 kg. (0.6 lbs.)
Length 3 0,5 kg. (1.1 lbs.)
Length 4 0,8 kg. (1.8 lbs.)

OSS * * 1 M

1 2 3 4 5

OSS Series 1 Filter Series - OSS 4 Valve Options


Filter and Element 1 - Bypass set at 0.2 bar (3
Model Code 2 Length psi) cracking pressure
mm (inch)
5
Construction
Sample model code: 1 - 109 (4.3)
2 - 142 (5.6) M - 100 Wire Mesh
OSS3D1M 3 - 203 (8.0)
4 - 277 (10.9)
MODEL CODE: PART 3
NUMBER Port Options
OSS1B1M 5003890 B- 3/4" NPT (Length 1 only)
C- 1-1/4" NPT (Length 2 only)
OSS2C1M 5003891 D- 1-1/2" NPT (Length 2, 3 only)
OSS2D1M 5003892 E- 3" NPT (Length 4 only)
OSS3D1M 5003893
OSS4E1M 5003894

Items not in bold are non-standard and may have a longer lead time
80 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
In-tank Filters
OSS Suction
Strainers
Flow Data

Element Flow Data

LENGTH A B SCREEN AREA


Housing Dimensions MM(INCH) MM(INCH) (IN2)
mm (inch)
1 68.6 (2.7) 109.2 (4.3) 40
2 86.4(3.4) 142.2(5.6) 128
3 101.6(4.0) 208.2(8.0) 200
4 132.1(5.2) 276.9(10.9) 379

OSS Filter Length 1 OSS Filter Length 2


Flow Rate - L/min Flow Rate - L/min
38 76 114 151 189 227 265 303 341 379 416 38 76 114 151 189 227 265 303 341 379 416
.4 .03 .4 .03
Pressure Drop (Bar)

Pressure Drop (Bar)


Pressure Drop (psi)

Pressure Drop (psi)

1 1/4
.3 .02 .3 .02
1 1/2

.14 .01 .14 .01

0 0
0 10 20 30 40 50 60 70 80 90 110 120 0 10 20 30 40 50 60 70 80 90 110 120
Flow Rate - USgpm Flow Rate - USgpm

OSS Filter Length 3 OSS Filter Length 4


Flow Rate - L/min Flow Rate - L/min
38 76 114 151 189 227 265 303 341 379 416 38 76 114 151 189 227 265 303 341 379 416
.4 .03 .4 .03
Pressure Drop (Bar)

Pressure Drop (Bar)


Pressure Drop (psi)

Pressure Drop (psi)

.3 .02 .3 .02

.14 .01 .14 .01

0 0
0 10 20 30 40 50 60 70 80 90 110 120 0 10 20 30 40 50 60 70 80 90 110 120
Flow Rate - USgpm Flow Rate - USgpm

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 81


In-tank Filters Flows to 380 L/min (100 USgpm)

OTM Tank
Mounted
Strainers

DESIGN SPECIFICATIONS

Rated flow: See chart below


Housing and Element Compatible with all petroleum based fluids, water glycols,
Compatibility: synthetic fluids and phosphate ester fluids
Temp range: -28 to +100C (-20 to +210F)
Material: Stainless Steel
Cast Iron
Dry weight: Length 1 0,1 kg. (0.20 lbs.)
(Approximate with element) Length 2 0,2 kg. (0.55 lbs.)
Length 3 0,3 kg. (0.65 lbs.)
Length 4 0,5 kg. (1.05 lbs.)
Length 5 1,0 kg. (2.15 lbs.)
Length 6 1,8 kg. (4.05 lbs.)
Bypass Valve: 5 psid in all OTM strainers

MODEL
CODE A B C D E SCREEN AREA RATED FLOW

Port Size mm (in) mm (in) mm (in) (sq. cm) (sq.inch) L/min & USgpm
OTM1 1" NPT 1/2" NPT 135.6 (5.3) 26.9 (1.06) 29.7 (1.1) 225.75 35 19 5
OTM2 1 1/4" NPT 3/4" NPT 207.5 (8.2) 30.4 (1.2) 34.5 (1.3) 412.80 64 38 10
OTM3 1 1/2" NPT 1" NPT 208.2 (8.2) 30.9 (1.2) 42.1 (1.6) 554.70 86 57 15
OTM4 2" NPT 1 1/4" NPT 229.6 (9.0) 34.2 (1.3) 53.8 (2.1) 806.25 125 95 25
OTM5 3" NPT 2" NPT 246.3 (9.7) 43.1 (1.7) 76.2 (3.0) 1677 260 190 50
OTM6 4" NPT 3" NPT 287 (11.3) 45.7 (1.8) 101.6 (4.0) 2031.75 315 380 100

MODEL CODE: PART


NUMBER

OTM1 5003895
OTM2 5003896
OTM3 5003897
OTM4 5003898
OTM5 5003899
OTM6 5003900

Standard items are in bold print.


82 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Indicating Inlet
Strainers

General Data detrimental to pump pressure drop gets into the Switch Circuit
operation. danger zone. Red indicates
These units have been an open bypass valve. The GREEN
designed for use in the The unit may be mounted in
any position desired. To indicator will also
intake lines of hydraulic automatically show red, BLUE
pumps to afford a degree of ensure proper operation of
the air bleed feature, (bypass condition) if the unit
protection from is accidentally operated RED C
NC

contaminants to the pump however, the inlet port must


be pointed down. without an element. The NO
and other components in the visual indicator can also be BLACK
hydraulic system. reassembled to provide a
Magnets memory function. If the
Bypass Valve protecting hood is removed
Magnets are available as an
An integral relief valve accessory and are installed and the rotary indicator
parallels the element and is in the filter on the outside of turned 180 on its stem, the normally closed terminals to
preset to open at a 0.1 bar the element. They act to unit will indicate the the common and normally
(2 psi) (standard) or 0.2bar attract and retain ferrous maximum opening of the open terminals.
(3 psi) (optional) pressure particles of all sizes, some of bypass and remain in that Switch actuation will also
drop across the element. which could be small enough position until reset by occur when the unit is
Element bypassing can be to pass through the element rotating the knurled accidentally operated
caused by excess flow rates, mesh and into the pump if projecting knob. without an element.
high fluid viscosity, dirt-loaded no magnets were present.
elements, or a combination A 1/2" pipe tap is provided
Electrical for connecting a conduit, and
of these. Indicators A lever-actuated electric lengths of color coded wires
Visual switch is mounted in the are soldered to the switch
Air Bleed
indicator enclosure. The terminals for connecting to
These strainers include a A highly visible mechanical switch is depressed by a the external circuit through
standard integral air bleed. It indicator is linked to the cam mounted to the bypass the conduit wires. The
provides faster pump bypass valve. The indicator valve just prior to the switch contacts are rated for
priming on startup and limits shows green when the opening of the valve. This 5 amps resistive loading up
the agglomeration of small bypass valve is closed and changes the completion of to 250V AC.
air bubbles into larger ones. progressively more yellow as the electrical switch circuit
Large air bubbles are a warning when the element from the common and the

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 83


10F, 50F Series Flows to 329 L/min (87 USgpm)
Pressure to 0.3 bar (5 psi) vacuum to 20 bar (300 psi) positive
Indicating Inlet
Strainers

Features and Benefits DESIGN SPECIFICATIONS

Stainless elements have Rated flow: See Table


149 micron (100 mesh) Filtration: Filter is supplied with 149 micron (100 mesh) wire cloth element.
screen to protect pumps Fluid compatibility: Standard model is compatible with most petroleum oil,
from solid contaminants water glycol, and water-in-oil fluids. Optional seals and coatings
are available for use in phosphate esters and oil-water emulsions.
Available flows to 329 See fluids and seals note in model code.
L/min (87 USgpm) on
Temp range: -40C to + 107C (-40F to 225F)
pressure inlets and 254
L/min (67 USgpm) on Pressure rating: 10F and 50F 0,3 bar (5 psi)
vacuum inlets Material: Cover Die Cast Aluminum
Housing Cast Aluminum
Standard integral air bleed
Dry weight: 10F 2,5kg (5.5 lbs)
feature prevents Approximate 50F 5,7kg (12.5 lbs)
formation of large
bubbles. This provides
faster priming of pumps
at startup and prevents Maximum Flow Ratings VACUUM INLET* PRESSURIZED INLET**
MODEL NORMAL SPECIAL NORMAL SPECIAL
pump damage This table presents SERIES SERVICE SERVICE SERVICE SERVICE
Housing can be adapted recommendations for use in L/min (USgpm) L/min (USgpm) L/min (USgpm) L/min (USgpm)
to handle most hydraulic both pressurized inlet 10FA 45 (12) 30 (8) 61 (16) 42 (11)
fluids systems and the more
50FB 106 (28) 76 (20) 140 (37) 95 (25)
Large, easy to read, common vacuum inlet
systems. The effects of fluid 50FC 178 (47) 125 (33) 257 (68) 167 (44)
standard visual indicator 50FD 254 (67) 178 (47) 329 (87) 238 (63)
(or optional electrical viscosity, specific gravity, and
indicator) informs operator fluid flow rate on the pump * 0.3 bar (5 psi) vacuum to 0 bar (0 psi)
inlet system (including the ** 0 bar (0 psi) to 20 bar (300 psi)
when element needs to For use with petroleum oil up to 48 cSt (225 SUS) with less than
be cleaned filter) have been taken into
457mm (18") lift on vacuum applications.
consideration. Even with a For use with petroleum oils above 48 cSt (225 SUS) and fire resistant fluids.
Elements can be cleaned bypass condition in effect
and reused due to element dirt loading, a
Standard bypass valve margin of pump protection is
protects against pump still afforded.
damage

** F * 1 ** * * * * **

1 2 3 4 5 6 7 8 9 10

Model Code 1 Package Size 5 Port Type 8 Bypass valve

10 - 10 size BB - G1 (formerly 1" BSPF) thd. 3 - 0.2 bar (3 psi) differential


50 - 50 size (10F only) opening pressure
Sample model code: FF - 4-bolt SAE flange 2 - 0.1 bar (2 psi) differential
2 Model Series SS - SAE straight thd. in housing opening pressure
10FA1BBMB3X12
F -Indicating type inlet filter (except 50FD)
PF - Inlet: NPTF pipe thd. in housing 9 Option
3 Port Size Outlet: 4-bolt SAE flange M - Magnets
A- 1" (10F) SF - Inlet: SAE Straight thd. in housing X - No Magnets
B- 1-1/2" (50F) Outlet: 4-bolt SAE flange (except
50FD) 10 Design Number
C- 2" (50F)
D- 2-1/2" (50F) 12 - Mechanical indicator or
6 Indicator
no indicator
4 Mean Filtration Rating E - Electrical 20 - Electrical indicator
1 -149 micron (100 mesh) L - Less (without) indicator parts
M - Mechanical

7 Seals

B - Buna - N
V - Viton

84 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


10F Series
Indicating Inlet
Strainers

10FA Model Series


mm (inch)
Cover can be rotated
.375-16 UNC 2B thd. in 90 increments to
22,5 (0.88) deep suit installation.
4 holes, 2 places
26,2
13,1 (1.03)
(0.52)
177,8 (7.00) min.
26,2 4 wires
(1.03)

52,4
(2.06) 114,3
(4.50) Visual
57,2 indicator
(2.25)
25,4 two places
(1.00)
SAE Flange Ports Mechanical Indicator Electrical Indicator

139,7 Memory
(5.50) reset knob
82,6 53,8
(3.25) 1/ " NPTF
2 thd. (2.12)

215,9
(8.50)
Clearance 203,2
required for 35,0 (8.00)
removal of (1.38) 203,2
cartridge 153,9 (8.00)
(6.06)
70,0 In In
(2.75)
50,0
(1.97)
Wrench
flats Inlet port Out Out
31,7 31,7 35,0
(1.25) (1.25) 70,0 (1.38)
Outlet port (2.75) For proper air bleed
operation, center line
must be horizontal with
Threaded Ports inlet port pointed down.

INLET AND OUTLET PORT THREADS


ELEMENT AREA
CM2 (IN2) PIPE THREAD* SAE STRAIGHT THREAD TUBE SIZE NPTF FLANGE* WELDED FLANGE

419.4 (65) 1" NPTF G1 (1" BSPF) 1.312-12 UN 1.000 FLI-8-08P-10 FLI-8-08W-10
*Not recommended

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 85


50F Series
Indicating Inlet
Strainers

50F* Model Series


mm (inch)
Cover can be rotated
in 90 increments to
.500-13 UNC 2B thd. suit installation.
26,9 (1.06) deep
4 holes, 2 places
A
B 177,8 (7.00) min.
4 wires

C
D 165,1
(6.50) Visual
82,6 indicator
(3.25)
E two places

SAE Flange Ports Mechanical Indicator Electrical Indicator

196,8 Memory
(7.75) reset knob
114,3 1/ " NPTF 53,8
2 (2.12)
(4.50) thd.

358,6 304,8
(14.12) 57,1 (12.00)
Clearance
required for (2.25)
304,8
removal of 255,8 (12.00)
cartridge (10.07)
114,3 In In
(4.50)
87,4
(3.44)
Wrench
flats Out
57,1 Inlet port Out Out
(2.25) 57,15
57,1 (2.25)
Outlet port 114,3
(2.25) (4.50) For proper air bleed
Threaded Ports operation, center line
must be horizontal with
inlet port pointed down.
INLET AND OUTLET PORT THREADS SAE FLANGE PORT DIMENSIONS
ELEMENT SAE
AREA PIPE STRAIGHT TUBE NPTF WELDED
MODEL CM2 (IN2) THREAD* THREAD SIZE FLANGE* FLANGE A B C D E

50FB 645,2 (100) 11/2" 1.875-12 UN 1.50 FLI-12-12P-10 FLI-12-12W-10 35,7 (1.41) 17,8 (0.70) 35,1 (1.38) 69,8 (2.75) 38,1 (1.50)
50FC 1419,4 (220) 2" 2.500-12 UN 2.00 FLI-16-16P-10 FLI-16-16W-10 42,9 (1.68) 21,3 (0.84) 38,9 (1.53) 77,8 (3.06) 50,8 (2.00)
50FD 1419,3 (220) 21/2" - - FLI-20-20P-10 FLI-20-20W-10 50,8 (2.00) 25,4 (1.00) 44,4 (1.75) 88,9 (3.50) 63,5 (2.50)
*Not recommended

86 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Spin-on Filters

General Data
Spin-on filters typically consist of a head mounted
directly in-line with the return piping and a canister
These are an effective and economical choice of filter
containing an element which screws onto a threaded
where the return line pressure is low and there are no
post. The canister seals to the head to prevent
large flow surges with the return line. They are also
leakage.
easily installed without specialty equipment or tooling.
Applications
Agricultural equipment -
tractors, spreaders,
harvesters
Metal forming presses
Strapping systems
Brush Chippers
Turf maintenance equipment
Small power units

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 87


Spin-on Filters Flows to 57 L/min (15 USgpm)
Pressures to 7 bar (100 psi)
OFRS15

Features and Benefits DESIGN SPECIFICATIONS

Simple spin-on element Rated flow: 57 L/min 15 USgpm)


design for easy Fluid compatibility: Compatible with most most petroleum oil, water glycol,
maintenance oil-in-water and water-in-oil fluids.
Temp range: 40C to +107C (-40F to +225F)
Bypass valves prevent
excessive pressure drop Pressure rating: Operating 7 bar (100 psi)
and accidental element Material: Head Die cast aluminum
collapse Bowl Carbon steel
Two available ports for Dry weight: 1,0 kg (2.2 lbs.)
use as gauge and/or
diagnostic ports

OFRS 15 * * *** * * * ** 10

1 2 3 4 5 6 7 8 9 10

OFRS15 Series 1 Filter Series - OFRS 5


Fluid Cleanliness Rating 8 Outlet Gauge Port
Filter and Element Target fluid Location (1/8" NPT)
Model Code 2 Flow Rating Code cleanliness level E - Location E
15 -15 USgpm (57 L/min) R03 16/14/12 X - No Gauge
Sample model code: R05 18/16/14
3 Port Type 9 Bypass Valve
OFRS15S2R03PBE1010 R10 20/18/15
B - G1 to ISO 228 XXX - no element 10 -Bypass valve set at
P - 1in NPT 0.6 bar (10 psi)
S - 1.312-12 UN SAE-16 6
25 - Bypass valve set at
straight thd. Pressure Gauge Option 1.7 bar (25 psi)
P - Pressure gauge 0-8 bar
4 Assembly Length (0-120 psi);l p/n 736129 10 Design Number
mm (inch) C - Color Coded Pressure 10 - Standard Design
1 - 194,6 (7.7) Gauge (For use with 1.7
2 - 250,4 (9.9) bar (25 psi) bypass only);
X - no element p/n P-232965-01
X - No Gauge
7
Inlet Gauge Port Location
(1/8" NPT)
B - Location B
X - No Gauge

88 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Spin-on Filters Flows to 57 L/min (15 USgpm)
Pressures to 7 bar (100 psi)
OFRS15

V019 1 B * R **

1 2 3 4 5 6

V019 Element 1 Series Designation 4 Element Length 6 Fluid Cleanliness Rating


Model Code V019 - Filter element for use mm (inch) Target fluid
with OFRS15 1 - 147 mm (5.8 in) Code cleanliness level
Sample model code: 2 - 203 mm (8.0 in) 03 16/14/12
2 Element Collapse Rating
V0191B2R03 05 18/16/14
5 Element Construction
1 - 10 bar (150 psi) 10 20/18/15
R - RPak
3 Seal Material
B - BunaN

Housing Dimensions
26,9 26,9 .375-16 UNC-2B thd. 19,1 (0.75) min. full thd.
mm (inch) (1.06) (1.06) 2 holes for mounting Mounting screw torque
20-27 Nm (15-20 ft-lb)
B Pressure gauge 3,05R (0.12R) Typ.
connection
E Pressure gauge connection1/8" NPTF pipe thd.
2 locations (see Model Code)
47,8
(1.88) 27,2 (1.07)

13,5
(0.53)
23,9
(0.94) 11,2 9,53/9,78R (0.375/0.385R) Typ.
11,2
(0.44) 7,87R (0.44)
(0.31R)

98,8
Optional pressure gauge (3.89)
49,3 44,4
(1.94) (1.75) Hex. - both ends
24,4
Approx. (0.96)
55,9
(2.20)

Std.
Inlet Outlet (length 1)
port port 194,6
(7.66)
Long
(length 2)
250,4
(9.86)
Std.
(length 1)
170,2
(6.70)
Long
(length 2)
226,1
(8.9)

12,7 (0.50) 97,5 Max.


Clearance required for removal of cartridge (3.84)

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 89


Spin-on Filters Flows to 60 L/min (15 USgpm)
Pressures to 7 bar (100 psi)
OFRS15
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9
Element Flow Data

OFRS 15 Element Length 1 OFRS 15 Element Length 2

Flow Rate - USgpm Flow Rate - USgpm


5 10 15 20 10 20 30 40
0,6 10 0,6 10
R03
0,5 8 0,5 8
Pressure drop - bar

Pressure drop - bar

Pressure drop - psid


Pressure drop - psid
R03 R05
0,4 6 0,4 6
R05
0,2 4 0,2 4
R10
0,1 R10 0,1
2 2
0 0
0 10 20 30 40 50 60 70 0 20 40 60 80 100 120 140
Flow Rate - L/min Flow Rate - L/min

Housing/Bypass Valve Flow Data

Flow Rate - USgpm Flow Rate - USgpm


0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 26 53
50
45 3,0
Pressure drop - bar

Pressure drop - psid


Pressure drop - psid

40
Pressure drop - bar

35 2,5 36
30
25 2,0
20
15 1,5 22
10
5 0,5
0
9.5 19 28 38 47 57 66 76 85 95
Flow Rate - L/min 50 100 150 200
Flow Rate - L/min

Sample P Calculation : OFRS15S2R03PBE1010 - Filter assembly having '2' length spinon filter element with micron
rating code '03' at 50 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific
gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.4 x 0.8/0.9 + 0.08 x 46/32 x 0.8/0.9
= 0.350 + 0.1
= 0.45 bar

90 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Spin-on Filters Flows to 95 L/min (25 USgpm)
Pressures to 7 bar (100 psi)
OFRS25

Features and Benefits DESIGN SPECIFICATIONS

Simple spin-on element Rated flow: Length 1 55 L/min (15 USgpm)


design for easy Length 2 95 L/min (25 USgpm)
maintenance Fluid compatibility: Suitable for use with petroleum based, oil-water emulsions,
high water based and most water-glycol fluids.
Bypass valve prevents Temp range: 40C to +107C (-40F to +225F)
excessive pressure drop
Pressure rating: Operating 7 bar (100 psi)
and accidental element
collapse Material: Head Die cast aluminum
Canister Carbon steel
Six available ports for use
Dry weight: 0,9 kg (2.0 lbs)
as gauge and/or
diagnostic ports

OFRS 25 * * *** * * * ** 10

1 2 3 4 5 6 7 8 9 10

OFRS25 Series 1 Filter Series - OFRS 5Fluid Cleanliness Rating 8 Outlet Gauge Port
Filter and Element Target fluid Location (1/8" NPTF)
Model Code 2 Flow Rating Code cleanliness level D - Location D
25 - 25 USgpm (95 L/min) R03 16/14/12 E - Location E
Sample model code: R05 18/16/14 F - Location F
3 Port Type R10 20/18/15 X - No Gauge
OFRS25S1R03PAF2510 NOTE: Gauges cannot be mounted side by
B - G1 (formerly 1" BSPF) thd. XXX no element side. If inlet and outlet gauges are required,
F - 1" SAE-4-bolt flange code 61 specify non-adjacent ports such as A and E.
P - 1" NPTF 6 Pressure Gauge Option
S - 1.312-12 UN SAE-16
P - Pressure gauge 0-120 psi 9 Bypass Valve
straight thd. for 1" OD tube
(0-8 bar); p/n 736129 XX - Non-bypass
4 Assembly Length X - No Gauge 25 - Bypass valve set at
mm (inch) 1.7 bar (25 psi)
7Inlet Gauge Port Location
1 - 194,1 (7.6)
2 - 250,4 (9.9) (1/8" NPTF) 10 Design Number
X - no element A - Location A 10 - Standard Design
B - Location B
C - Location C
X - No Gauge

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 91


Spin-on Filters Flows to 95 L/min (25 USgpm)
Pressures to 7 bar (100 psi)
OFRS25

V019 1 B * R **

1 2 3 4 5 6

V019 Element 1 Series Designation 4 Element Length 6


Fluid Cleanliness Rating
Model Code V019 - Filter element for use mm (inch) Target fluid
with OFRS25 1 - 147 (5.8) Code cleanliness level
Sample model code: 2 - 203 (8.0) 03 16/14/12
2 Element Collapse Rating
V0191B2R03 05 18/16/14
5 Element Construction
1 - 10 bar (150 psi) 10 20/18/15
R - RPak
3 Seal Material
B - BunaN

Housing Dimensions .375-16 UNC-2B thd. 15,7 (0.62) min. full thd.
mm (inch) 4 holes for mounting
53,8 Mounting screw torque 20-27 Nm (15-20 ft-lb)
(2.12)
26,9 F Pressure gauge connection
(1.06) 1/8" NPTF pipe thd.
C
6 locations (see Model Code)
B E
40,4
(1.59)
81,0
(3.19)
Approx.
66,7
(2.62)
D 23,9 47,6
(0.94) (1.88)

A .375-16 UNC-2B thd. 16,3 (0.64) min. full thd.


4 holes each end only when F port type is specified.
Use Vickers FL1-8-08P-10 or FL1-8-08W -10 flanges.
103,1 52,3
(4.06) (2.06)
51,6 23,9
56,4 (2.03) 26,2
(2.22) (0.94) (1.03) 13,1
(0,52)

Inlet Outlet Std.


port port (length 1) 26,2
Optional 194,1 (1.03)
pressure (7.64)
gauge Long
(length 2)
250,4 Std.
(9.86) (length 1)
170,2
(6.70)
Long
(length 2)
226,1
(8.9)

97,5
12,7 Clearance required for removal of cartridge (3.84)
(0.50)

92 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Spin-on Filters Flows to 95 L/min (25 USgpm)
Pressures to 7 bar (100 psi)
OFRS25
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9
Element Flow Data

OFRS Element Length 1 OFRS Element Length 2

Flow Rate - USgpm Flow Rate - USgpm


5 10 15 20 10 20 30 40
0,6 10 0,6 10
R03
0,5 8

Pressure drop - PSID


Pressure drop - bar
0,5 8

Pressure drop - PSID


Pressure drop - bar

R05
0,4 R03 0,4 6
6
R05
0,2 4 0,2 4
R10
0,1 R10 0,1 2
2
0 0
0 10 20 30 40 50 60 70 0 20 40 60 80 100 120 140
Flow Rate - L/min Flow Rate - L/min

Housing/Bypass Valve Flow Data B


Flow Rate - USgpm
26 53

3,0

Pressure drop - PSID


2,5 36
Pressure drop - bar

2,0

1,5 22

0,5

50 100 150 200


Flow Rate - L/min

Sample P Calculation : OFRS25S1R03PAF2510 - Filter assembly having '1' length spinon filter element with micron
rating code '03' at 70 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific
gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.25 x 0.8/0.9 + 0.42 x 46/32 x 0.8/0.9
= 0.220 + 0.53
= 0.75 bar

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 93


Spin-on Filters Flows to 113 LPM (30 USgpm)
Pressures to 10 bar (150 psi)
OFSS30

Features and Benefits DESIGN SPECIFICATIONS

Simple spin-on element Rated flow: 115 L/min (30 USgpm)


design for easy Temp range: -27C to +107C (-20F to +225F)
maintenance Pressure rating: Operating 10 bar (150 psi)
Fatigue 20 bar (300 psi)
Bypass valves prevent
excessive pressure drop Material: Head Die cast aluminum
and accidental element Bowl Carbon steel
collapse Dry weight: 1,0 kg (2.2 lbs.)
Two available ports for Filter Heads, Elements and Indicator must be ordered separately for OFSS30 Filters.
use as gauge and/or Note: Only 1 indicator gauge option available, P/N 5003906.
diagnostic ports
Example: OFSS30E2 Filter Head
V176CBR05 Element
5003906 Indicator Gauge
OFSS30 * 2

1 2 3

OFSS30 Series 1 Filter Series - OFSS30 3 Valve Options


Filter Head 2 - Bypass set at 1.7 bar
Model Code 2 Port Options (25 psi) cracking pressure
B - 3/4" NPT
Sample model code: E - SAE 12
OFSS30B2
MODEL CODE: PART
NUMBER

OFSS30B2 5003904
OFSS30E2 5003905

V176 C B ***

1 2 3 4

V176 Element 1 Series Designation 3 Seal Material 4 Fluid Cleanliness Rating


Model Code V176 - For use with OFSS30 B - BunaN Target fluid
spin-ons Code cleanliness level
Sample model code: R05 18/16/14
2 Element Collapse Rating
V176CBR10 R10 20/18/15
C - 6.9 bar (100 psi) Low W15 Water Removal
Collapse
MODEL CODE: PART
NUMBER

V176CBRO5 5003901
V176CBR10 5003902
V176CBW15 5003903

94 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Spin-on Filters Flows to 113 LPM (30 USgpm)
Pressures to 10 bar (150 psi)
OFSS30

Visual 0-100 psi,


color coded indicator
gauge 1/8-27 NPTF, 1/8-27 NPT
part number 5003906

(1.2)

(2.1)

Housing Dimensions
mm (inch)

Optional Gauge Ports 1/8-27 NPTF


Tapped and Plugged

1-12 UNF Thd (ref)

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 95


Spin-on Filters
OFSS30
Flow Data

Element Flow Data

OFSS30 5 Micron Element Flow OFSS30 10 Micron Element Flow


(L/min)
0 25 50 75 100 0 25 50 75 100
15 4 bar
.25

Pressure Drop (psi)


Pressure Drop (psi)

3 .20
10
.15
2

.10
5
1
.05

0 0 .00
0 5 10 15 20 25 30 35 0 5 10 15 20 25 30
Flow (USgpm) Flow (USgpm)

Housing Flow Data

Housing OFSS30 Water Removal Element Flow

(L/min)
0 25 50 75 100
(L/min)
0 25 50 75 100
20 bar 40 bar
2.5
1.2
15 1.0 30 2.0
Pressure Drop (psi)

Pressure Drop (psi)

0.8
1.5
10 20
0.6
1.0
0.4
5 10
0.5
0.2

0 0.0 0 0.0
0 5 10 15 20 25 30 0 5 10 15 20 25 30
Flow (USgpm) Flow (USgpm)

96 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Spin-on Filters Flows to 130 L/min (35 USgpm)
Pressures to 35 bar (500 psi)
OFRP35 Series

Features and Benefits DESIGN SPECIFICATIONS

Ideal for charge pump Rated flow: 130 L/min (35 USgpm)
applications and hydrostatic Fluid compatibility: Compatible with most petroleum oil, water glycol,
transmissions oil-in-water and water-in-oil fluids.
Spin-on element design Temp range: -29C to +121C (-20F to +250F)
for easy maintenance Pressure rating: Operating 35 bar (500 psi)
One port available for use Fatigue 35 bar (500 psi)
with electric indicator Material: Head Die cast aluminum
Bypass valves prevent Bowl Steel, cold rolled
excessive pressure Dry weight: (Approximate) Length 1 1,0 kg (2.2 lbs.)
drop and accidental Length 2 2,2 kg (4.8 lbs.)
element collapse

Filter Head and Element must be ordered separately for OFRP35 Filters.

OFRP 35 ** * **

1 2 3 4 5

OFRP35 Series 1 Filter Series - OFRP 4 Indicator Option* 5 Bypass valve


Filter Head V - Visual indicator left side, 25 -Bypass valve set at
Model Code 2 Flow rating blank plate right side, for 1.7 bar (25 psi)
35 - 132.5 L/min (35 USgpm) SA and SB ports for SA and SB ports
Sample model N - No indicator 50 -Bypass valve set at
code for Head: 3 Port type E - Electrical, single post, 3 3 bar (50 psi)
SA - 1.062 12 UN SAE-12 bar (43 psid) for ST Port for ST port type only
OFRP35SAV25 only 3 bar (50 psi)
(3/4" tube)
SB - 1.312 12 UN SAE-16
MODEL CODE: PART (1" tube) * Indicators are included and
NUMBER
ST - 1.062 12 UN SAE-12 shipped installed on V
OFRP35SAV25 5002466 (3/4" tube) with third and E indicator options.
OFRP35STE50 5002467 port to tank Indicators may also be
OFRP35SBV25 5002468 ordered separately as
OFRP35SBN25 5002469 stated below:
MODEL CODE: PART
NUMBER

VI 25 5002470
EL25DC 5002471
EL25ACDC 5002472
EL50DC 5002473

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 97


Spin-on Filters Flows to 130 L/min (35 USgpm)
Pressures to 35 bar (500 psi)
OFRP35 Series V0311 B * R **

1 2 3 4 5

V0311 Element Sample model code: 1 Filter Element 5 Fluid Cleanliness Rating
Model Code V0311B2R05 V0311 - Filter element for use Target fluid
with OFRP35 only Code cleanliness level
MODEL CODE: PART
NUMBER 05 18/16/14
2 Seal material
VO311B1R05 5002474 08 19/17/14
B - BunaN
VO311B2R05 5002475 12 20/18/15 (length 2 only)
VO311B2R12 5002476 3 18 22/19/16
Element Length
VO311B1R08 5002477 mm (inch) Fluid Cleanliness Rating:
VO311B2R08 5002478 1 - 147 (6.0) 05, 08, 18 rated for 150 PSID
2 - 203 (9.4)
VO311B1R18 5002479 collapse, 12 rated for 300 PSID
VO311B2R18 5002480 4 collapse and recommended for
Element Construction
ST port type
Housing Dimensions R - R-Pak
mm (inch) OFRP35 with optional electrical indicator OFRP35 with optional electrical indicator
35,1 35,1
(1.38) 3/8-16UNC-28
x .60 Min Thd (1.38) 3/8-16UNC-28
4-Plcs x .60 Min Thd
4-Plcs

35,1 35,1 (1.38)


(1.38)

52,8 (2.08) 52,8 (2.08)


98,0 (3.86) 61,01
150,6 (5.93) (2.40)
113,5 (4.47)

OFRP35 with B1 Length Filter Element OFRP35 with B2 Length Filter Element
101,6 (4.00) 101,6 (4.00)
34,0
(1.34) 34,0
(1.34)
Visual Indicator
5002470

214,9
(8.46)
WIRING DIAGRAM 151,6
303,0 (11.93)

FOR ELECTRICAL (5.97)


INDICATORS
94,2 (3.71) DIA
Indicator Options
239,8 (9.44)

Differential
Pressure
To Remove Spin-on Assy.

23,1 (.91) Min Clearance


23,1 (.91) Min Clearance

RBW Actuation To Remove Spin-on Assy


Filter
Head

5002472 5002471 5002473 5002470


3 wire AC/DC Single post Single post Visual
2 amps at 24 V DC 6-30 V DC 6-30 V DC N/A
2 amps at 110 V AC
25 psid 25 psid 50 psid 25 psid
EL25ACDC EL25DC EL50DC VI25
94,2 (3.71) DIA
98 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Spin-on Filters Flows to 130 L/min (35 USgpm)
Pressures to 35 bar (500 psi)
OFRP35 Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9
Element Flow Data
mm (inch)

OFRP35 R-Pak Element Length 1 OFRP35 R-Pak Element Length 2

Flow Rate - USgpm Flow Rate - USgpm


0 5 10 15 20 25 30 35 0 5 10 15 20 25 30 35
10 10
0,6 0,6 05
Pressure Drop - bar

Pressure Drop - bar


Pressure Drop - psi

Pressure Drop - psi


8 8
0,5 05 0,5
0,4 6 0,4 6
0,3 08 4 0,3 4
08
0,2 18 0,2 12
2 18 2
0,1 0,1
0,0 0,0 0
0 20 40 60 80 100 120 0 20 40 60 80 100 120
Flow Rate L/min Flow Rate L/min

Housing/Bypass Valve Flow Data ST Port Option

Flow - USgpm
0 5 10 15 20 25 30 35 40 45 50 55 60
1,0 15
Pressure Drop - bar

Pressure Drop - psi

0,7 10
OFRP35P
OFRP35B & OFRP35S

0,3 5

0 0
0 25 50 75 100 125 150 175 200 225
Flow (L/min)

SA and SB Port Options ST Port Option

IN OUT IN OUT

1.7 bar 3.4 bar


(25 PSI) (50 PSI)

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 99


Spin-on Filters Flows to 227 L/min (60 USgpm)
Pressures to 7 bar (100 psi)
OFRS60 Series

Features and Benefits DESIGN SPECIFICATIONS

Available with Vickers Rated flow: Length 1 114 L/min (30 USgpm)
proprietary R-Pak media Length 2 227 L/min (60 USgpm)
Fluid compatibility Compatible with most petroleum ol, water glycol,
Simple spin-on element oil-in-water and water-in-oil fluids
design for easy
Temp range: 40C to +107C (-40F to +225F)
maintenance
Pressure rating: Operating 7 bar (100 psi)
Optional bypass valves
Material: Head Die cast aluminum
prevent excessive Canister Carbon steel
pressure drop and
Dry weight: Length 1 4,4 kg (5.0 lbs)
accidental element Length 2 5,6 kg (6.5 lbs)
collapse
Six available ports for use
as gauge and/or
diagnostic ports
H20-Pro Water Removing
Element available

OFRS 60 * * * * ** * * * ** 10

1 2 3 4 5 6 7 8 9 10 11 12

OFRS60 Series 1 Series designation - OFRS 6


Element construction 9 Inlet gauge port location
Filter and Element R - R-Pak (code 03,05,10,20) (1/8" NPTF)
Model Code 2 Flow rating W- Water Removal (10, length A - Location A
60 -60 USgpm (227 L/min) 2 only) B - Location B
Sample model code: X - no element C - Location C
3 Mounting X No Gauge
OFRS601S1R03PAF2510 7 Fluid cleanliness rating
1 - Body or line mounting
10 Outlet gauge port
2 - Reservoir mount flange Target fluid
(outlet) cleanliness Element location (1/8" NPTF)
Code level Construction D - Location D
4 Port type 03 16/14/12 R-Pak E - Location E
B- G1-1/2 (formerly 1/2" BSPF) 05 18/16/14 R-Pak F - Location F
thd. X - No Gauge
10 20/18/15 R-Pak or NOTE: Gauges cannot be mounted side by
F- 1-1/2" SAE 4-bolt flange water side. If inlet and outlet gauges are required,
P- 1-1/2" NPTF removal specify non-adjacent ports such as A and E.
S- 1.875-12 UN SAE-24 20 22/19/16 R-Pak
straight thd. for 1-1/2" 11
XX - No element Bypass valve
OD tube
XX - No bypass valve
5 Canister Length 8 Pressure gauge option 25 - Bypass valve set at
P - Pressure gauge; p/n 736129 1.7 bar (25 psi) cracking
mm (inch)
X - No Gauge pressure
1 - 184 (7)
2 - 286 (11) 12 Design number
X - no element
10 -Standard Design

100 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Spin-on Filters Flows to 227 L/min (60 USgpm)
Pressures to 7 bar (100 psi)
OFRS60 Series
V021 1 B * * **

1 2 3 4 5 6

V021 Element 1 Filter Element 3 Seal Material 6 Fluid Cleanliness Rating


Model Code V021 - Filter element for use B - Buna-N Target fluid
with HS22 and OFRS- cleanliness Element
Sample model code: 60 series filters (R-Pak 4 Canister Length Code level construction
construction only) mm (inch) 03 16/14/12 R-Pak
VO211B1R03
1 - 184 (7) 05 18/16/14 R-Pak
2 Element Collapse Rating 2 - 286 (11) 10 20/18/15 R-Pak or
1 - 10 bar (150 psi) Low water
Pressure 5 Element Construction removal
R - R-Pak (code 3,5,10,20) 20 22/19/16 R-Pak
W- Water Removal (10, length
2 only)

Housing Dimensions
OFRS-60
Body or Line Mounting
mm (inch)

.5000-13 UNC-2B thd., 0.875 min. full thd.


4 holes each end only when F port type is specified.
Use Vickers FL1-12-12P-10 or FL1-12-12W-10 flanges.
69,9
(2.75)
34,8
56,4 (1.37)
(2.22)
31,7
(1.25) 35,6
Length 1 (1.41)
Inlet Outlet 242,8
port port (9.56) 17,9
(0.70)
Length 2
344,4
Optional (13.56)
pressure
gauge Length 1
211,1
(8.31)

Length 2
312,7
(12.31)

128,5
136,5 (5.06)
33,3 (1.31) Clearance required for removal of cartridge (5.38)

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 101


Spin-on Filters Flows to 227 L/min (60 USgpm)
Pressures to 7 bar (100 psi)
OFRS60 Series
Housing Dimensions Note:
A, B, C Inlet gauge port locations
OFRS-60-2
D, E, F Outlet gauge port locations
Manifold Mounting
Outlet Port Connection Pressure gauge in locations D and F will require additional fitting to clear
mm (inch) mounting bolt hex nuts. Use Aeroquip No. 2040-2-2S or equivalent must be
ordered separately.

.375-16 UNC-2B thd., 0.75 min. full thd.


F Pressure gauge 53,8 2 holes for mounting
connection 1/ 8" NPTF (2.12) Mounting screw torque 15-20 lb. ft (20-27 Nm)
pipe thd. 6 locations 41,3 D
(see Model Code) (1.62)
E
69,8
B 139,7 (2.75) 34,7
(5.50) 38,1 (1.37)
81,0 35,7
(3.19) (1.50)
(1.41)
40,4 Approx.
(1.59) 85,7
(3.38)
17,8
(0.70)
D
26,9 .5000-13 UNC-2B thd., 0.875 min. full thd.
(1.06) A 4 holes each end only when F port type is specified.
53,8 Use Vickers FL1-12-12P-10 or FL1-12-12W-10 flanges.
(2.12)
122,9
(2.84)
144,5 Seal groove to accept A-225 seal 120,7
(5.69) 5,38 (2.12)OD x 47,7 (1.88) (4.75)
ID x 3,05 (0.12) C/S
56,4 60,2
(2.22) (2.37) 35,7
(1.41)
31,7
(1.25)

Inlet
port Outlet
port 17,8
(0.70)
10,3 (0.41)
Optional Thru holes for
pressure mounting 211,1
gauge (8.31*)

128,5
(5.06)
136,5
33,3 (1.31) Clearance required for removal of cartridge (5.38)
* Add 101,6 (4.00) for long 10mm element.

102 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Spin-on Filters Flows to 227 L/min (60 USgpm)
Pressures to 7 bar (100 psi)
OFRS60 Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9
Element Flow Data

OFRS60 R-Pak Element Length 1 OFRS60 R-Pak Element Length 2

Flow Rate - USgpm Flow Rate - USgpm


7 20 33 13 40 66
R03 R03

Pressure drop - psid


Pressure drop - psid

Pressure drop - bar


Pressure drop - bar

0,4 6 0,4 6
R05 R05
0,3 0,3
R10 R10
0,2 3 0,2 3
R20 R20
0,1 0,1
0 0
0 25 50 75 100 125 150 0 50 100 150 200 250 300
Flow Rate - L/min Flow Rate - L/min

Housing/Bypass Valve Flow Data

Housing Flow Data Bypass Valve

Flow Rate - USgpm Flow Rate - USgpm


20 40 26 53

3,0
Pressure drop - psid
Pressure drop - bar

0,4

Pressure drop - psid


6
Pressure drop - bar

2,5 36
0,3
2,0
0,2 3
1,5 22
0,1 0,5
0
0 75 150 225 50 100 150 200
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : OFRS601S1R03PAF2510 - Filter assembly having '1' length filter element with micron rating
code '03' at 100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.11 x 0.8/0.9 + 0.29 x 46/32 x 0.8/0.9
= 0.090 + 0.36
= 0.45 bar

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 103


Spin-on Filters Flows to 450 L/min (120 USgpm)
Pressures to 14 bar (200 psi)
HS22 Series

Features and Benefits DESIGN SPECIFICATIONS

Designed to comply with Rated flow: Length 1 227 L/min (60 USgpm)
ANSI specifications and Length 2 454 L/min(120 USgpm)
ISO cleanliness standards Fluid compatibility Compatible with most petroleum ol, water glycol,
oil-in-water and water-in-oil fluids
Dual flow path design Temp range: -32C to +107C (-25F to +225F)
maximizes flow capability
Pressure rating: Operating 14 bar (200 psi)
and service life
Material: Head Aluminum
Spin-on element make
servicing fast and easy Dry weight: Length 1 7.3 kg (16 lbs)
Length 2 8.6 kg (19 lbs)
High efficiency
replacement elements in
standard configurations
(R-Pak) to meet Target
Cleanliness Levels
HS22 1 ** * * N B * * **

1 2 3 4 5 6 7 8 9 10

HS22 Series 1 Filter Series - HS22 5 Indicator options 9 Element Construction


Filter and Element 1 - No indicator R - R-Pak (code 3, 5,10, 20)
Model Code 2 Element Collapse Rating 2 - 13.7 bar (200 psi) gauge W- Water Removal (10, length
1 - 150 psi Low Pressure 4 - 4 bar (60 psi) gauge 2 only)
Sample model code: X - No Element
3 6 Receptical
Port options
HS221SD32NB2R05 N - None 10 Fluid cleanliness rating
BD - G1-1/2 to ISO 228
ME - 1-1/2" SAE 4 bolt Flange Target fluid
Code 61 (M12 x 1.75) 7 Seal material Code cleanliness level
SD - 1.875 - 12 UN sae-24 B - Buna-N 03 16/14/12 or better
str. Thd (1-1/2 tube) 05 18/16/14 or better
FE - 1-1/2" SAE 4 bolt Flange 8 Assembly Length 10 20/18/15 or better
Code 61 (UNC) mm (inch) 20 22/19/16 or better
1 - 253 (10)
4 Valve options XX No Element
2 - 355 (14)
3 - Bypass set at 1.7 bar X - No Element
(25 psi) cracking pressure
4 - Bypass set at 3 bar (50
psi) cracking pressure

104 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Spin-on Filters Flows to 450 L/min (120 USgpm)
Pressures to 14 bar (200 psi)
HS22 Series

V021 1 B * * **

1 2 3 4 5 6

V021 Element 1 Filter Element 3 Seal Material 6 Fluid Cleanliness Rating


Model Code V021 - Filter element for use B - Buna-N Target fluid
with HS22 and OFRS- cleanliness Element
Sample model code: 60 series filters (R-Pak 4 Canister Length Code level construction
construction only) mm (inch) 03 16/14/12 R-Pak
V0211B1R03
1 - 184 (7) 05 18/16/14 R-Pak
2 Element Collapse Rating 2 - 286 (11) 10 20/18/15 R-Pak or
1 - 10 bar (150 psi) Low water
Pressure 5 Element Construction removal
R - R-Pak (code 3, 5,10, 20) 20 22/19/16 R-Pak
W- Water Removal (Code 10,
length 2 only)

Housing Dimensions 286,0


mm (inch) (11.26)

60 165,5
146 (6.52)
(2.36) (5.75)

171,0
(6.73)
Mounting Holes
3/8"-16 - 4 Places

40,0
286 (1.57)
(11.26)

35,5 Refer to
(1.40) Model Code

128,3
(5.05)

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 105


Spin-on Filters Flows to 450 L/min (120 USgpm)
Pressures to 14 bar (200 psi)
HS22 Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9

Element Flow Data

HS22 R-Pak Element Length 1 HS22 R-Pak Element Length 2

Flow Rate - USgpm Flow Rate - USgpm


7 20 33 13 40 66
R03 R03

Pressure drop - psid


Pressure drop - psid

Pressure drop - bar


Pressure drop - bar

0,4 6 0,4 6
R05 R05
0,3 0,3
R10 R10
0,2 3 0,2 3
R20 R20
0,1 0,1
0 0
0 25 50 75 100 125 150 0 50 100 150 200 250 300
Flow Rate - L/min Flow Rate - L/min

Housing/Bypass Valve Flow Data

Housing Bypass Valve

Flow Rate - USgpm Flow Rate - USgpm


26 79 26 79
1,2

Pressure drop - psid


Pressure drop - psid

Pressure drop - bar


Pressure drop - bar

1,0 15 5,0 73
50 PSID Valve 65
0,8 4,0
9 3,0 45 44
0,6
0,4 2,0 25 PSID Valve
0,2 3 1,0 15

0 100 200 300 400 0 100 200 300 400


Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : HS221SD32NB2RO5 - Filter assembly having '2' length filter element with micron rating code
'05' at 250 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.3 x 0.8/0.9 + 0.37 x 46/32 x 0.8/0.9
= 0.260 + 0.47
= 0.73 bar

106 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Pressure Filters

General Data
Pressure filters are used to protect downstream In some applications, pressure filters are used as
components from contamination levels beyond the isolation filters to protect specific components such
recommended cleanliness target. Because they are as proportional or servo valves. Typically these
typically sized for the output of the pump, pressure filters filters are non-bypass and employ elements that are
tend to be smaller than return line filters when cylinders capable of withstanding full system differential
are present. In systems using accumulators, pressure pressure without collapsing. While these filters are
filters must be sized according to the large effective flow sized to handle only a specific components' required
rates present during parts of the duty cycle. flow, the use of high collapse elements result in a
higher cost than elements used in housings with
bypass valves. Most isolation filters are direct-
mounted beneath the valve which can save space
as well as reduce plumbing costs.

Applications
Paper Mills Test and simulation
Steel Mills equipment
Injection molding Entertainment stage
machines equipment
Motion bases Hydrostatic drives
Sawmill equipment Power generation
turbine control systems
Flight simulators

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 107


Pressure Filters Flows to 19 L/min (5 USgpm)
Pressures to 200 bar (3,000 psi)
ECF Series

Features and Benefits DESIGN SPECIFICATIONS

Integrated throwaway Rated flow: 19 L/min (5 USgpm)


element which is screwed Fluid compatibility: Compatible with all petroleum-/oil-based and synthetic fluids.
into the manifold port for Not rated for use with fluoro-rubber or ethylene propylene seals.
last chance filtration
Temp range: -30C to +121C (-22F to 250F)
Pressure rating: Operating 200 bar (3000 psi)
Cavity: BC20-S3
Material: Head Aluminum
Bowl Aluminum
Dry weight: (Approximate) 0,11 kg (0.25 lbs)

ECF 1 SB 1 J 3 * V ***

1 2 3 4 5 6 7 8 9

ECF Series 1 Filter Series - ECF 6


Assembly Length
Filter and Element mm (inch)
Model Code 2 Element Collapse Rating 3 - 80.2 (3.16)
1 - 17 bar (250 psi) low
7 Element Construction
Sample model code: collapse
C - Standard construction
ECF1SB1J3CV025 3 Port Options M - Wire screen
SB - 1.312-12 UN SAE-16
8 Seal Material
straight thread
V - Viton-A
4 Valve Options
9 Fluid Cleanliness
1 - Non-Bypass
(Screw directly into cavity) Fluid
Cleanliness Element
5 Code Rating Construction
Indicator Options
015 20/18/15 C-Pak
J - No indicator
025 Wirescreen
100 Wirescreen

108 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Pressure Filters Flows to 19 L/min (5 USgpm)
Pressures to 207 bar (3,000 psi)
ECF Series

Housing Dimensions
mm (inch)
48.9
(1.929)
Spotface
35.5
(1.399) 1.5
HEX
1 5/16-12UN-2B IN.
SAE-16 PORT
19.05
19.05 0.76 3.3 (0.75)
(0.75) (0.03) (0.13)
Min. Full Thread

INLET 61.0 (2.400)


45 68.6 (2.710) 80.2 66.9
INLET PORT BETWEEN
20.3 - 50.8 (0.80-2.00) FROM TOP

(3.157) (2.634)
20

25.3
(.998)

19.05 (0.75) Pilot Drill


1 5/16 - 12UN-2A IN.
25.5 (1.003)
31.3 (1.234)

OUTLET

Housing/Element Flow Data

Flow versus pressure drop:


150 SUS (32 cSt) oil with specific gravity of <0.9

ECF15 ECF 25/150


Flow Rate - USgpm Flow Rate - USgpm
0 1 2 3 4 5 6 0 2 4 6 8 10 12 14 16 18
1,50 1,50
Pressure drop - psid

20 20
Pressure drop - psid
Pressure drop-bar

Pressure drop-bar

1,25 1,25
16 16
1,00 1,00
0,75 12 12
0,75
0,50 8 8
0,50
0,25 4 0,25 4
0 0 0 0
0 4 8 12 16 20 24 0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72
Flow Rate - L/min Flow Rate - L/min

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 109


Pressure Filters Flows to 110 L/min (29 USgpm)
Pressures to 100 bar (1,500 psi)
LV2P Series

Features and Benefits DESIGN SPECIFICATIONS

Beta Ratio: x(c) = 1000 Rated flow: Length 3 60 L/min (16 USgpm)
to ISO 16889 Length 6 110 L/min (29 USgpm)
Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
Designed to comply with Optional seals available for phosphate esters.
ANSI specifications and
Temp range: -26C to +121C (-15F to +250F)
ISO cleanliness standards
Pressure rating: Operating 100 bar (1500 psi)
Visual, electrical, and Fatigue 100 bar (1500 psi)
electrical indicators with
Material: Head Aluminum
lamp options for system Bowl Aluminum
design flexibility
Dry weight: Length 3 1,5 kg (3.3 lbs)
Poppet type by-pass valve (Approximate) Length 6 1,8 kg (4.0 lbs)
construction
High efficiency
replacement elements in
standard configurations
(C-Pak) to meet Target
Cleanliness Levels
High collapse elements
available for non-bypass
applications
LV2P * SA * ** * * * **

1 2 3 4 5 6 7 8 9

LV2P Series 1 Filter Series - LV2P 5 Indicator Options UL - Electrical 4.9 bar (70 psi),
Filter Assembly Model Hirschmann w 230 volt
AN - Visual 4.9 bar (70 psi),
Code 2 light
Element Collapse Rating No Connector
UH - Electrical 4.9 bar
1 - 17 bar (250 psi) Low LN - Visual 2 bar (30 psi),
(70 psi), Hirschmann
Sample model code: Collapse No Connector
4 - 103 bar (1500 psi) High JN - No Indicator (plug), 6 Seal Material
LV2P1SA4LNB3C05 Collapse No Connector
RB - Electrical 2 bar (30 psi), B- Buna-N
3 Port Options Brad Harrison V- Viton-A
SA - 1.062 - 12UN SAE-12 RJ - Electrical 2 bar (30 psi), 7
Hirschmann w 24 volt Assembly Length
(3/4" tube)
light mm (inch)
4 Valve Options RK - Electrical 2 bar (30 psi), 3 - 187 (7.36)
Hirschmann w 115 volt 6 - 254 (10.0)
1 - Non-Bypass
light
4 - Bypass set at 2.9 bar (43 8 Element Construction
psi) cracking pressure RL - Electrical 2 bar (30 psi),
Hirschmann w 230 volt C - C-Pak (Code 03, 05, 10, 20)
6 - Bypass set at 6 bar (90
light H - H-Pak (Code 03, 05, 10)
psi) cracking pressure
RH - Electrical 2 bar (30 psi), X - no element
Hirschmann
UB - Electrical 4.9 bar 9 Fluid Cleanliness Rating
(70 psi), Brad Harrison Target fluid
UJ - Electrical 4.9 bar Code cleanliness level
(70 psi), Hirschmann 03 16/14/12 or better
w 24 volt light 05 18/16/14 or better
UK - Electrical 4.9 bar
10 20/18/15 or better
(70 psi), Hirschmann
w 115 volt light 20 22/19/16 or better
XX no element

110 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Pressure Filters Flows to 110 L/min (29 USgpm)
Pressures to 100 bar (1,500 psi)
LV2P Series

V0513 * * * **

1 2 3 4 5

V0513 Element 1 Filter Element 4 Element Construction


Model Codes V0513 - For use with LV2P C - C-Pak (code 03, 05, 10, 20)
series housings H - H-Pak (code 03, 05, 10)
Sample model code:
2 Seal Material 5 Fluid Cleanliness Ratings
V0513B6C05
B - Buna-N Target fluid
V - Viton-A Code cleanliness level
03 16/14/12 or better
3 Element Length 05 18/16/14 or better
mm (inch) 10 20/18/15 or better
3 - 140 (5.51) 20 22/19/16 or better
6 - 207 (8.15)

Housing Dimensions 85
mm (inch) (3.35) 42.5
(1.67)
17.5
3/8-24UNF-2B IN. (0.69)
14 DEEP
4 PL'S
35
(1.38)

50 6
(1.97) (0.24)

Length 3
180
(7.08)

Length 6
242
(9.72)

75
(2.95)
68
( 2.68)
Clearance
Drain Plug G 1/2 Required
(standard for sizes 330 & 660 for Element
optional for sizes 30 - 280) Removal

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 111


Pressure Filters Flows to 110 L/min (29 USgpm)
Pressures to 100 bar (1500 psi)
LV2P Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of < 0.9

LV2P Filter Elements Flow Data

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 25

C - pak 3 0.029 (1.581) 0.020 (0.816) 0.013 (0.723) 0.008 (0.433)


6 0.015 (0.818) 0.011 (0.585) 0.007 (0.360) 0.004 (0.204)
H - pak 3 0.059 (3.210) 0.033 (1.784) 0.018 (0.993) xxx
6 0.025 (1.394) 0.015 (0.818) 0.009 (0.488) xxx
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Housing/Bypass Valve Flow Data

Housing Bypass Valve

Flow Rate - USgpm Flow Rate - USgpm


0 2 4 6 8 10 12 14
0 5 10 15 20 25 30 10,0
0,97 14 142.5
132.5

Pressure drop - psid


0,83 12 9,0
Pressure drop - bar
Pressure drop - bar

Pressure drop - psid

0,69 10 122.5
8,0 112.5
0,55 8
7,0 102.5
0,41 6
92.5
0,28 4 6,0
82.5
0,14 2 5,0 72.5
0 0 0 10 20 30 40 50 60
0 19 38 57 76 95 114
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : LV2P1SA4LNB3C05 - Filter assembly having '3' length filter element with micron rating code
'05' at 50 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.20x 0.8/0.9 + 50 x 0.020 x 46/32 x 0.8/0.9
= 0.170 + 1.61
= 1.78 bar

112 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Pressure Filters Flows to 330 L/min (87 USgpm)
Pressures to 100 bar (1,500 psi)
LV4P Series

Features and Benefits DESIGN SPECIFICATIONS

Beta Ratio: x(c) = 1000 Rated flow: Length 5 160 L/min (42 USgpm)
to ISO 16889 Length 7 330 L/min (87 USgpm)
Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
Designed to comply with Optional seals available for phosphate esters.
ANSI specifications and
Temp range: -40C to +121C (-40F to +250F))
ISO cleanliness standards
Pressure rating: Operating 100 bar (1500 psi)
Visual, electrical, and Fatigue 100 bar (1500 psi)
electrical indicators with
Material: Head Aluminum
lamp options for system Bowl Aluminum
design flexibility
Dry weight: Length 5 3,7 kg (8.2 lbs)
High efficiency (Approximate) Length 7 8,0 kg (17.6 lbs)
replacement elements in
standard configurations
(C-Pak) to meet Target
Cleanliness Levels
Poppet type by-pass valve
construction
High collapse elements
available for non-bypass
applications
LV4P * S* * ** * * * **

1 2 3 4 5 6 7 8 9

LV4P Series 1 Filter Series - LV4P 5 Indicator Options UL - Electrical 4.9 bar (70 psi),
Filter Assembly Hirschmann w 230 volt
AN - Visual 4.9 bar (70 psi),
Model Code 2 light
Element Collapse Rating No Connector
UH - Electrical 4.9 bar
1 - 17 bar (250 psi) LN - Visual 2 bar (30 psi),
(70 psi), Hirschmann
Sample model code: Low Collapse No Connector
LV4P1SC4LNB5C05 4 - 103 bar (1500 psi) JN - No Indicator (plug), 6 Seal Material
High Collapse No Connector
RB - Electrical 2 bar (30 psi), B - Buna-N
3 Port Options Brad Harrison V - Viton-A
Length 5: RJ - Electrical 2 bar (30 psi), 7
Hirshmann w 24 volt Assembly Length
SC - 1.625 - 12UN SAE-20
light mm (inch)
Str. thd. (11/4" tube)
RK - Electrical 2 bar (30 psi), 5 - 247 (9.73)
Length 7:
Hirschmann w 115 volt 7 - 312 (12.29)
SD - 1.875 - 12UN SAE-24
Str. thd. (11/2" tube) light
8 Element Construction
RL - Electrical 2 bar (30 psi),
4 Valve Options Hirschmann w 230 volt C - C-Pak (code 03, 05, 10,
light 20)
1 - Non-Bypass
RH - Electrical 2 bar (30 psi), H - H-Pak (code 03, 05, 10)
4 - Bypass set at 2.9 bar (43
Hirschmann X - no element
psi) cracking pressure
6 - Bypass set at 6 bar (90 UB - Electrical 2 bar (70 psi),
Brad Harrison 9 Fluid Cleanliness Rating
psi) cracking pressure
UJ - Electrical 4.9 bar Target fluid
(70 psi), Hirschmann Code cleanliness level
w 24 volt light 03 16/14/12 or better
UK - Electrical 4.9 bar
(70psi), Hirschmann 05 18/16/14 or better
w 115 volt light 10 20/18/15 or better
20 22/19/16 or better

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 113


Pressure Filters Flows to 330 L/min (87 USgpm)
Pressures to 100 bar (1,500 psi)
LV4P Series

V0513 * * * **

1 2 3 4 5

V0513 Element 1 Filter Element 4 Element Construction


Model Codes V0513 - For use with LV4P C - C-Pak (code 03, 05, 10, 20)
series housings H - H-Pak (code 03, 05, 10)
Sample model code:
2 Seal Material Fluid Cleanliness Rating
V0513B5C05
B - Buna-N Target fluid
V - Viton-A Code cleanliness level
03 16/14/12 or better
3 Element Length 05 18/16/14 or better
mm (inch) 10 20/18/15 or better
5 - 147 (5.8) 20 22/19/16 or better
7 - 180 (7.09)

Housing Dimensions 85
mm (inch) (3.35) 42.5
(1.67)
17.5
3/8-24UNF-2B IN. (0.69)
14 DEEP
4 PL'S
35
(1.38)

Length 5
65 6
(2.56) (0.24)

Length 7
85
(3.35)

Length 5
240
(9.45)

Length 7
313
(12.32)

Length 5
95
(3.74)

Length 7
105
Length 5 Length 7 (4.13)
95 130
( 3.74) ( 5.12)
Clearance
Drain Plug G 1/2 Required
(standard for sizes 330 & 660 for Element
optional for sizes 30 - 280) Removal

114 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Pressure Filters Flows to 330 L/min (87 USgpm)
Pressures to 100 bar (1,500 psi)
LV4P Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of < 0.9

LV4P Filter Elements Flow Data


'K' factor - bar/lpm (psi/gpm)
ELEMENT TYPE / SIZE MICRON RATING
03 05 10 25

C - pak 5 0.013 (0.717) 0.009 (0.479) 0.005 (0.252) 0.004 (0.193)


7 0.005 (0.294) 0.004 (0.214) 0.003 (0.162) 0.002 (0.095)
H - pak 5 0.017 (0.919) 0.010 (0.569) 0.006 (0.321) xxx
7 0.008 (0.421) 0.004 (0.244) 0.003 (0.153) xxx
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Housing/Bypass Valve Flow Data


Length 5 Housing Length 5 Bypass

Flow Rate - USgpm Flow Rate - USgpm


0 10 20 30 40 50 0 5 10 15 20 25 30 35 40
0.96 14 25,0 352.5
0,8 12
Pressure drop - bar

Pressure drop - bar


312.5
Pressure drop - psid

Pressure drop - psid


0.68 10 20,0
272.5
0,6 8 232.5
15,0
0.41 6 192.5
0,3 4 10,0 152.5
0.13 2 112.5
0 0 5,0 72.5
0 37.8 75.7 113.5 151.4 189.25 0 20 40 60 80 100 120 140 160
Flow Rate - L/min Flow Rate - L/min
Length 7 Housing Length 7 Bypass

Flow Rate - USgpm Flow Rate - USgpm


0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 80 90
1,0 14 362
24,0 337
0,8 12
Pressure drop - bar

Pressure drop - bar


Pressure drop - psid

Pressure drop - psid


21,0 312
0,7 10 287
18,0 262
0,6 8 237
0,4 6 15,0 212
12,0 187
0,3 4 162
0,1 2 9,0 137
112
0 0 6,0 87
0 38 76 114 151 189 227 265 0 50 100 150 200 250 300 350
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : LV4P1SC4LNB5C05 - Filter assembly having '5' length filter element with micron rating code
'05' at 100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.10 x 0.8/0.9 + 100 x 0.009 x 46/32 x 0.8/0.9
= 0.088 + 1.143
= 1.23 bar
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 115
Pressure Filters Flows to 90 L/min (24 USgpm)
Pressures to 280 bar (4,000 psi)
HF2P Series

Features and Benefits DESIGN SPECIFICATIONS

Beta Ratio: x(c) = 1000 Rated flow: Length 1 45 L/min (12 USgpm)
to ISO 16889 Length 2 91 L/min (24 USgpm)

Designed to comply with Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water and
ANSI specifications and water-in-oil fluids. Optional seals available for phosphate esters.
ISO cleanliness standards Temp range: -26C to +121C (-15F to +250F)
Visual, electrical, and Pressure rating: Operating 280 bar (4000 psi)
electrical indicators with Fatigue 280 bar (4000 psi)
lamp options for system Material: Head Ductile iron
design flexibility Bowl Carbon Steel
Conforms to HF2 Dry weight: Length 1 4,6 kg (10.1lbs)
(Approximate) Length 2 5,9 kg (134lbs)
automotive specifications
Compact design for use with
servo and proportional valves
Manifold mounting option
for system flexibility
High efficiency
replacement elements in
standard configurations
(C-Pak) to meet Target
Cleanliness Levels HF2P * ** * ** * * * **
High collapse elements
available for non-bypass 1 2 3 4 5 6 7 8 9
applications

HF2P Series 1 Filter Series - HF2P RB - Electrical 2 bar (30 psi), UK - Electrical 4.9 bar
Filter and Element Brad Harrison (70 psi), Hirschmann
RH - Electrical 2 bar (30 psi), w 115 volt light
Model Code 2 Element Collapse Rating Hirschmann UL - Electrical 4.9 bar (70 psi),
1 - 17 bar (250 psi) Low RJ - Electrical 2 bar (30 psi), Hirschmann w 230 volt
Sample model code: Collapse Hirschmann w 24 volt light
4 - 207 bar (3000 psi) High light
HF2P1SA4LNB2C05 Collapse RK - Electrical 2 bar (30 psi), 6 Seal Material
NOTE: Use 1 only with bypass valve or Hirschmann w 115 volt
monitored P indicator. B - Buna-N
light V - Viton-A
RL - Electrical 2 bar (30 psi),
3 Port Options Hirschmann w 230 volt 7 Assembly Length
BA - G3/4 to ISO 228 light
SA - 1.062 - 12UN SAE-12 TB - Electrical 7.9 bar mm (inch)
(3/4" tube) (115 psi), Brad Harrison 1 - 211.9 (8.3)
WS - Subplate mounting TH - Electrical 7.9 bar 2 - 304.9 (12.0)
(115 psi), Hirschmann
8 Element Construction
4 Valve Options TJ - Electrical 7.9 bar
(115 psi), Hirschmann C - 17 bar (250 psi)
1 - Non-Bypass
w 24 volt light Low Collapse
4 - Bypass set at 2.9 bar TK - Electrical 7.9 bar
(43 psi) cracking pressure H - 207 bar (3000 psi)
(115 psi), Hirschmann High Collapse
6 - Bypass set at 6 bar w 115 volt light
(90 psi) cracking pressure X - no element
TL - Electrical 7.9 bar (115
psi), 9 Fluid Cleanliness Rating
5 Indicator Options Hirschmann w 230 volt
Target fluid
AN - Visual 4.9 bar (70 psi), light Code cleanliness level
No Connector UB - Electrical 4.9 bar
JN - No Indicator (plug), (70 psi), Brad Harrison 03 16/14/12 or better
No Connector UH - Electrical 4.9 bar 05 18/16/14 or better
LN - Visual 2 bar (30 psi), (70 psi), Hirschmann 10 20/18/15 or better
No Connector UJ - Electrical 4.9 bar
20 22/19/16 or better
ON - Visual 7.9 bar (115 psi), (70 psi), Hirschmann
w 24 volt light XX no element
No Connector

116 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Pressure Filters Flows to 90 L/min (24 USgpm)
Pressures to 280 bar (4,000 psi)
HF2P Series
V304 * * * * **

1 2 3 4 5 6

V304 Element 1 Filter Element 3 Seal Material 5 Element Construction


Model Code V304 - For use with HF2P B - Buna-N C - C-Pak (code 03, 05, 10, 20)
series filters V - Viton-A H - H-Pak (code 03, 05, 10)
Sample model code:
2 Element Collapse Rating 4 Element Length 6Fluid Cleanliness Ratings
V3041B1C05
1 - 17 bar (250 psi) mm (inch) Target fluid
(C-Pak only) 1 - 101 (4) Code cleanliness level
5 - 207 bar (3000 psi) 2 - 203 (8) 03 16/14/12 or better
(H-Pak only) 05 18/16/14 or better
10 20/18/15 or better
20 22/19/16 or better

Housing Dimensions
mm (inch)
88.9
Subplate Mounting Outlet (3.50) Inlet Indicator Plug 21.4
7 44.5
(0.28) (1.75) (.08)
15.9
25.4 (0.63)
(1.00) 52 86
80 (2.05) (3.39)
(3.15)
17.5 31.8
(0.69) (1.25)

31.8 17 104
8.6 (0.34) thru (1.25) (0.67) (4.09)
4PL's
5/16-18UNC x 4.25 long
grade 8 bolts for 0.5
engagement are recommended
(4 req'd). Torque 9-12lb-ft (12-16Nm)

27 HEX 79.4
(1.06) (3.13)
7 24.2
(0.95) Inlet Outlet
(0.28)
6.75
(0.27)
96 98
(3.78) (3.86)

Refer to
Model Code

24 HEX
(0.95)

75 (2.96)
76.2 Clearance for
(3.00) Element Removal

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 117


Pressure Filters Flows to 90 L/min (24 USgpm)
Pressures to 280 bar (4,000 psi)
HF2P Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9

HF2P Filter Elements Flow Data

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 25

C - pak 1 0.037 (2.046) 0.032 (1.735) 0.017 (0.924) 0.010 (0.531)


2 0.018 (1.011) 0.016 (0.858) 0.008 (0.457) 0.005 (0.262)
H - pak 1 0.044 (2.396) 0.031 (1.688) 0.019 (1.026) xxx
2 0.021 (0.865) 0.015 (0.820) 0.009 (0.499) xxx

Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Housing/Bypass Valve Flow Data

Housing Bypass Valve


Flow Rate - USgpm Flow Rate - USgpm
11 21 0 2 4 6 8 10 12 14 16 18 20
25,0
1,2 17
322.5
Pressure drop - psid

Pressure drop - psid


20,0
Pressure drop-bar

Pressure drop-bar

0,8 272.5

15,0 222.5

172.5
0,4 6
10,0
122.5

0 5,0 72.5
0 20 40 60 80 100 0 10 20 30 40 50 60 70 80
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : HF2P1SA4LNB2C05 - Filter assembly having '2' length filter element with micron rating
code '05' at 50 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.26 x 0.8/0.9 + 50 x 0.016 x 46/32 x 0.8/0.9
= 0.220 + 1.01
= 1.23 bar

118 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Pressure Filters Flows to 113.5 L/min (30 USgpm)
Pressures to 275.5 bar (4,000 psi)
MF2P Series

Features and Benefits DESIGN SPECIFICATIONS

Beta Ratio: x(c) = 1000 Rated flow: Length 5 68 L/min (18 USgpm)
to ISO 16889 Length 7 113.5 L/min (30 USgpm)

Designed to comply with Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
ANSI specifications and Optional seals available for phosphate esters.
ISO cleanliness standards Temp range: -26C to +121C (-15F to +250F)
Visual, electrical, and Pressure rating: Operating 276 bar (4000 psi)
electrical indicators with Fatigue 276 bar (4000 psi)
lamp options for system Material: Head Ductile iron
design flexibility Bowl Steel
High efficiency Dry weight: Length 5 3,9 kg (8.3 lbs)
(Approximate) Length 7 4,5 kg (9.9 lbs)
replacement elements in
standard configurations
(C-Pak) to meet Target
Cleanliness Levels
Poppet type leak by-pass
valve construction

MF2P 1 SA 5 ** * * * **

1 2 3 4 5 6 7 8 9

MF2P Series 1 Filter Series - MF2P 5 Indicator Options 7 Assembly Length


Filter Assembly Model AN - Visual 4.9 bar (70 psi), mm (inch)
Code 2 Element Collapse Rating No Connector 5 - 210 (8.27)
1 - 17 bar (250 psi) Low JN - No Indicator (plug), 7 - 263 (10.36)
Sample model code: Collapse No Connector
UB - Electrical 4.9 bar 8 Element Construction
MF2P1SA5ANB5C05 3 Port Options (70 psi), Brad Harrison C - 250 psi Low Collapse
SA - 1.062 - 12UN SAE-12 UJ - Electrical 4.9 bar X - no element
(3/4" tube) (70 psi), Hirschmann
w 24 volt light 9 Fluid Cleanliness Rating
4 Valve Options UK - Electrical 4.9 bar Target fluid
(70 psi), Hirschmann Code cleanliness level
5 - Bypass set at 100 psi
w 115 volt light 03 16/14/12 or better
(7 bar) cracking pressure
UL - Electrical 4.9 bar (70 psi),
05 18/16/14 or better
Hirschmann w 230 volt
light 10 20/18/15 or better
UH - Electrical 4.9 bar 20 22/19/16 or better
(70 psi), Hirschmann XX no element
6 Seal Material
B - Buna-N
V - Viton-A

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 119


Pressure Filters Flows to 113.5 L/min (30 USgpm)
Pressures to 275.5 bar (4,000 psi)
MF2P Series

V0512 * * C **

1 2 3 4 5

V0512 Element 1 Filter Element 4 Element Construction


Model Codes V0512 - For use with MF2P C - C-Pak (code 03, 05, 10, 20)
series housings
Sample model code: 9 Fluid Cleanliness Rating
2 Seal Material Target fluid
V0512B5C05 Code cleanliness level
B - Buna-N
V - Viton-A 03 16/14/12 or better
05 18/16/14 or better
3 Element Length 10 20/18/15 or better
mm (inch)
20 22/19/16 or better
5 - 117 (5)
7 - 169 (7)

Housing Dimensions 41
92 (1.61)
mm (inch) 6
(3.62) Clogging
(0.24) Indicator
1 1/16-12 UN
Port

35 35
(1.38) (1.38)

90
(3.54)

Length 5
204
(8.03)

Length 7
257
(10.12)

SW 27

55 76,2
(2.17) (3.00)
55 86
(3.39)
OUTLET R9

INLET
45 40
(1.37) (1.57)

mounting threads
3/8-16 UNC

120 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Pressure Filters Flows to 113.5 L/min (30 USgpm)
Pressures to 275.5 bar (4,000 psi)
MF2P Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of < 0.9

MF2P Filter Elements Flow Data

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 25

C - pak 5 0.014 (0.750) 0.011 (0.602) 0.008 (0.443) 0.005 (0.263)


7 0.009 (0.509) 0.008 (0.411) 0.005 (0.290) 0.003 (0.169)
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Housing/Bypass Valve Flow Data

Housing Bypass
Flow Rate - USgpm Flow Rate - USgpm
0 5 10 15 20 25 30 0 2 4 6 8 10 12 14
16 20,0
1,0 272.5

Pressure Drop - psid


14
Pressure Drop - psid
Pressure Drop - bar

Pressure Drop - bar

247.5
0,6 12 15,0 222.5
10 197.5
0,5
8 172.5
0,4 6 10,0 147.5
4 122.5
0,2 97.5
2
0,0 0 5,0 72.5
0 15 30 45 60 75 90 105 0 10 20 30 40 50 60
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : MF2P1SA5UNB5C05 - Filter assembly having '5' length filter element with micron rating
code '05' at 50 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.3 x 0.8/0.9 + 50 x 0.011 x 46/32 x 0.8/0.9
= 0.260 + 0.69
= 0.95 bar

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 121


Pressure Filters Flows to 53 L/min (14 USgpm)
Pressures to 310 bar (4,500 psi)
OFPH03,
OFPH05 Series

Features and Benefits DESIGN SPECIFICATIONS

Beta Ratio: x(c) = 1000 Rated flow: Length 3 23 L/min (6 USgpm)


to ISO 16889 Length 5 45 L/min (12 USgpm)
Length 6 53 L/min (14 USgpm)
Designed to comply with
ANSI specifications and Fluid Compatibility: Compatible with most petroleum oil, water glycol, oil-in-water and
water-in-oil fluids. Optional seals available for phosphate esters.
ISO cleanliness standards
Temp range: 26C to +121C (-15F to +250F)
Visual and electrical
Pressure Rating: Operating: 310 bar (4500 psi)
indicators with lamp
Fatigue: 310 bar (4500 psi)
options for system design
flexibility Material: Head Ductile Iron
Bowl Carbon Steel
Poppet type by-pass valve
construction Dry weight: (Approximate) Length 3 2,3 kg (5.1 lbs)
Length 5 4,7 kg (10.4 lbs)
Wide range of element Length 6 5,4 kg (11.9 lbs)
lengths for maximum
design flexibility
High efficiency
replacement elements in
standard configurations
(H-Pak) to meet Target
Cleanliness Levels
Designed to mount
directly underneath D03,
D05 and CETOP Valves.
The fluid is filtered prior to
entering the valve P
(Pressure) Port
OFPH *** S * ** * * **

1 2 3 4 5 6 7 8

OFPH Series 1 Filter Series - OFPH 5


Indicator Options 7 Element Series
Filter Model Codes TN - Visual 7.9 bar (115 psi), (collapse rating)
2 Body Size (D03 or D05) No Connector H - 207 bar (3000 psi)
Sample model code: and Assembly Length JN - No Indicator (plug), X - no element
mm (inch) No Connector
OFPH031SATNBH03 8
031 - OFPH031 226 (8.9) TB - Electrical 7.9 bar Fluid Cleanliness Rating
051 - OFPH051 254 (10.0) (115 psi), Brad Harrison Target fluid
052 - OFPH052 325 (12.8) TJ - Electrical 7.9 bar Code cleanliness level
(115 psi), Hirschmann 03 16/14/12 or better
3 Valve Options w 24 volt light 05 18/16/14 or better
S - Without bypass valve TK - Electrical 7.9 bar
(115 psi), Hirschmann 10 20/18/15 or better
4 w 115 volt light 20 22/19/16 or better
Port Options
TL - Electrical 7.9 bar XX no element
A - Modular stacking,
(115 psi), Hirschmann
Bowl Side A
w 230 volt light
B - Modular stacking,
TH - Electrical 7.9 bar
Bowl Side B
(115 psi), Hirschmann
6 Seals
B - Buna-N
V - Viton-A

122 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Pressure Filters Flows to 53 L/min (14 USgpm)
Pressures to 310 bar (4,500 psi)
OFPH03,
OFPH05 Series

***** * * H **

1 2 3 4 5

V0603, V0604 and 1 Element Series 2 Seals 4 Element Collapse


V0114 Series V0603 - For use with B - Buna-N Pressure
Replacement Element OFPH031 series V - Viton-A H - 207 bar (3000 psi)
Model Codes filters
V0604 - For use with 3 Element Length 5 Fluid Cleanliness Rating
OFPH051 series 3 - OFPH031 03 16/14/12 or better
Sample model code:
filters (V0603 only) 05 18/16/14 or better
V0603B3H03 V0114 - For use with 5 - OFPH051 10 20/18/15 or better
OFPH052 series (V0604 only)
filters 20 22/19/16 or better
6 - OFPH052
(V0114 only)

Housing Dimensions - D03 Pattern


mm (inch)

D03 Pattern

P
Indicator Port
G 1/2 1.81
A B (46mm)

8.90 1.77
(226mm) (45mm)
Clearance Required
for Element Removal

D05 Pattern

T T

Indicator Port 2.68


G 1/2 (68.2mm)
A B
P
Clearance Required
for Element Removal
3.15
0.24 DF 60 Z DF 110 Z (80mm)
(6mm) 9.76 12.56
(248mm) (319mm)

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 123


Pressure Filters Flows to 53 L/min (14 USgpm)
Pressures to 310 bar (4,500 psi)
OFPH03,
Flow versus pressure drop:
OFPH05 Series 150 SUS (32 cSt) oil with specific gravity of < 0.9
Flow Data

OFPH Filter Elements Flow Data

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 25

H - pak 3 0.075 (4.466) 0.067 (3.978) 0.053 (3.096) 0.031 (1.795)


5 0.059 (3.210) 0.033 (1.784) 0.018 (0.993) 0.023 (1.227)
6 0.025 (1.394) 0.015 (0.818) 0.009 (0.488) 0.010 (0.563)
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Housing Flow Data

OFPH031 OFPH051 OFPH052


Flow Rate - USgpm Flow Rate - USgpm Flow Rate - USgpm
0 1 2 3 4 5 6 7 0 2 4 6 8 10 12 0 5 10 15 20
4.0 60 2.0 30 80
5.0

Pressure drop - bar


50

Pressure drop - psi


25
Pressure drop - bar
Pressure drop - bar

Pressure drop - psi


Pressure drop - psi

3.0 1.5 4.0 60


40 20
30 15 3.0 40
2.0 1.0
20 10 2.0
1.0 0.5 20
10 5 1.0

0 0 0
0 5 10 15 20 25 0 10 20 30 40 0 10 20 30 40 50 60 70
Flow Rate - L/min Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : OFPH031SAATNBHC05 - Filter assembly having '3' length filter element with micron rating
code '05' at 20 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 1.6 x 0.8/0.9 + 20 x 0.067 x 46/32 x 0.8/0.9
= 1.400 + 1.7
= 3.1 bar

124 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Pressure Filters Flows to 570 L/min (150 USgpm)
Pressures to 345 bar (5,000 psi)
HF4P Series

Features and Benefits DESIGN SPECIFICATIONS

Beta Ratio: x(c) = 1000 Rated flow: Length 3 189 L/min (50 USgpm)
to ISO 16889 Length 6 379 L/min (100 USgpm)
Length 7 568 L/min (150 USgpm)
Designed to comply with Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water and
ANSI specifications and water-in-oil fluids. Optional seals available for phosphate esters.
ISO cleanliness standards Temp range: -26C to +121C (-15F to +250F)
Visual and electrical Pressure rating: Operating 345 bar (5000 psi)
indicators with lamp Fatigue 345 bar (5000 psi)
options for system Material: Head Ductile Iron
design flexibility Bowl Carbon Steel
Conforms to HF4 Lid Ductile Iron
specifications Dry weight: Length 3 28,8 kg (63.4 lbs)
(Approximate) Length 6 38,7 kg (85.3 lbs)
Fatigue rated to 5000 psi Length 7 51,5 kg (113.6 lbs)
for maximum reliability in
rugged applications
Top loading design to
ease maintenance and
minimize spillage
Multiple filter element HF4P * ** * ** * * * **
lengths for design flexibility
High efficiency 1 2 3 4 5 6 7 8 9
replacement elements in JN - No Indicator (plug), UL - Electrical 4.9 bar (70 psi),
1 Filter Series - HF4P
standard configurations No Connector Hirschmann w 230 volt
(C-Pak) to meet Target RB - Electrical 2 bar (30 psi), light
2 Element Collapse Rating
Cleanliness Levels Brad Harrison UH - Electrical 4.9 bar
1 - 10 bar (150 psi) Low RJ - Electrical 2 bar (30 psi), (70 psi), Hirschmann
High collapse elements
Collapse Hirschmann w 24 volt
available for non-bypass 4 - 207 bar (3000 psi) light 6 Seal material
applications High Collapse RK - Electrical 2 bar (30 psi), B - Buna-N
Series 3
Hirschmann w 115 volt V - Viton-A
Port options light
Filter and Element
BD - G11/2 to ISO 228 RL - Electrical 2 bar (30 psi), 7 Assembly Length
Model Code ME - 11/2" SAE 4 bolt Flange Hirschmann w 230 volt mm (inch)
Code 61 (M12 x 1.75) light 3 - 447 (17.6)
Sample model code: MR - 11/2" SAE 4 bolt Flange RH - Electrical 2 bar (30 psi), 6 - 685.3 (27)
HF4P1SD4LNB6C05 Code 62 (M16 x 2.0) Hirschmann 7 - 923.5 (36.4)
SD - 1.875 - 12 UN SAE-24 TB - Electrical 7.9 bar
str. Thd. (11/2" tube) (115 psi), Brad Harrison 8 Element construction
FE - 11/2" SAE 4 bolt Flange TJ - Electrical 7.9 bar
Code 61 (UNC) C - 10 bar (150 psi)
(115 psi), Hirschmann
FR - 11/2" SAE 4 bolt Flange Low Collapse
w/ 24 volt light
Code 62 (UNC) H - 207 bar (3000 psi)
TK - Electrical 7.9 bar High Collapse
WS - Subplate mounting (115 psi), Hirschmann
X - no element
w/ 115 volt light
4 Valve options TL - Electrical 7.9 bar 9 Fluid cleanliness rating
1 - Non-Bypass (115 psi), Hirschmann
Target fluid
4 - Bypass set at 2.9 bar w/ 230 volt light Code cleanliness level
(43 psi) cracking pressure TH - Electrical 7.9 bar
6 - Bypass set at 6 bar (115 psi), Hirschmann 03 16/14/12 or better
(90 psi) cracking pressure UB - Electrical 4.9 bar 05 18/16/14 or better
(70 psi), Brad Harrison 10 20/18/15 or better
5 Indicator options UJ - Electrical 4.9 bar 20* 22/19/16 or better
AN - Visual 4.9 bar (70 psi), (70 psi), Hirschmann XX no element
No Connector w 24 volt light
* C-Pak only
LN - Visual 2 bar (30 psi), UK - Electrical 4.9 bar
No Connector (70 psi), Hirschmann
w 115 volt light

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 125


Pressure Filters Flows to 570 L/min (150 USgpm)
Pressures to 345 bar (5,000 psi)
HF4P Series
V405 * * * * **

1 2 3 4 5 6

V405 Element 1 Filter Element - V405 4 Element Length 6 Fluid Cleanliness Rating
model code mm (inch) Target fluid
2 Element Collapse Rating 3 - 229 (9) Code cleanliness level
(Meets HF4 Standard)
1 - 10 bar (150 psi) 6 - 457 (18) 03 16/14/12
4 - 206.9 bar (3000 psi) 7 - 686 (27) 05 18/16/14
Sample model code:
High Collapse 10 20/18/15
V4051B3C03 NOTE: Use 1 only with bypass valve or 5 Element Construction
monitored delta P indicator. 20 22/19/16
C - C-Pak (code 03, 05, 10,
3 20)
Seals H - H-Pak (code 03, 05, 10)
B - Buna-N
V - Viton-A
Housing Dimensions Drain Plug
25.4 (1.00) 50.8
mm (inch) Hex 14.2 (2.00)
(0.56) 7.9 Outlet
thru (0.31)
57.2
158.8 4 PL'S (2.25)
(6.25)
79.4
(3.13) 114.3
(4.50)
Vent Plug
73 Inlet
(2.88) 146.1 Refer to
(5.75) Model Code Indicator
63.5 Port
(2.50)
127
(5.00)
133.4
22.4 (5.25) View X - Subplate Mounting
(0.88) 66.7
(2.63)

Inlet & Outlet = 31.8 (1.25)


O-ring = 2 x 1. .139

Refer to
Model
Code

Inlet (SAE-24 or G 1.5")


Outlet
Port on opposite face

70
(2.76)

35.1
Bolt Thread (1.38)
View X
E D C
A B C D E
mm mm mm mm mm
(inch) (inch) (inch) (inch) (inch)
B
A ME 69.8 37.9 35.7 17.9 35.1
(2.75) (1.375) (1.406) (.703) (1.38)
MR 79.3 39.4 36.5 18.2 35.1
(3.125) (1.56) (1.437) (.718) (1.38)
FE 69.8 37.9 35.7 17.9 35.1
(2.75) (1.375) (1.406) (.703) (1.38)
FR 79.3 39.4 36.5 18.2 35.1
(3.125) (1.56) (1.437) (.718) (1.38)

126 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Pressure Filters Flows to 570 L/min (150 USgpm)
Pressures to 345 bar (5,000 psi)
HF4P Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9

HF4P Filter Elements Flow Data

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 20

C -pak 3 0.003 (0.168) 0.003 (0.140) 0.001 (0.078) 0.001 (0.044)


6 0.001 (0.080) 0.001 (0.066) 0.001 (0.037) 0.001 (0.021)
7 0.001 (0.051) 0.001 (0.043) 0.001 (0.024) 0.001 (0.013)
H -pak 3 0.004 (0.206) 0.003 (0.145) 0.002 (0.088) xxx
6 0.002 (0.096) 0.001 (0.068) 0.001 (0.041) xxx
7 0.001 (0.062) 0.001 (0.044) 0.001 (0.026) xxx
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Housing/Bypass Valve Flow Data


Housing Bypass Valve
Flow Rate - USgpm Flow Rate - USgpm
26 79 0 10 20 30 40 50 60 70 80 90
1,00 15 11,0 157
147
Pressure drop - psid

Pressure drop - psid


10,0
Pressure drop - bar

Pressure drop - bar

0,75
137
9,0
127
0,50 7
8,0 117
107
0,25 7,0
97
0 6,0 87
0 100 200 300 400
0 50 100 150 200 250 300 350
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : HF4P1SD4LNB6C05 - Filter assembly having '6' length filter element with micron rating
code '05' at 200 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.26 x 0.8/0.9 + 200 x 0.001 x 46/32 x 0.8/0.9
= 0.220 + 0.25
= 0.47 bar

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 127


Pressure Filters Flows to 454 L/min (120 USgpm)
Pressures to 410 bar (6,000 psi)
HF3P Series

Features and Benefits


Beta Ratio: x(c) = 1000
to ISO 16889
Designed to comply with
ANSI specifications and DESIGN SPECIFICATIONS
ISO cleanliness standards Rated flow: Length 1 106 L/min (28 USgpm)
Visual, electrical, and Length 2 208 L/min (55 USgpm)
electrical indicators with Length 4 344 L/min (91 USgpm)
lamp options for system Length 5 454 L/min (120 USgpm)
design flexibility Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water and
Conforms to HF3 water-in-oil fluids. Optional seals available for phosphate esters.
automotive specifications Temp range: -26C to +121C (-15F to +250F)
Fatigue rated to 6000 psi Pressure rating: Operating 410 bar (6000 psi)
for maximum reliability in Fatigue 410 bar (6000 psi)
the most rugged Material: Head Ductile iron
applications Bowl Carbon Steel
Reverse flow valve option Dry weight: Length 1 20,3 kg (44.8lbs)
for hydrostatic (Approximate) Length 2 22,5 kg (49.5lbs)
(Approximate) Length 4 28,5 kg (62.9lbs)
transmission applications (Approximate) Length 5 43,4 kg (95.7lbs)
Multiple filter element
lengths for design flexibility HF3P * ** * ** * * * **
High efficiency
replacement elements in 1 2 3 4 5 6 7 8 9
standard configurations
(C-Pak) to meet Target 1 Filter Series - HF3P 5 Indicator Options UH - Electrical 4.9 bar
Cleanliness Levels (70 psi), Hirschmann
AN - Visual 4.9 bar (70 psi),
2 Element Collapse Rating
UJ - Electrical 4.9 bar
High collapse elements No Connector
(70 psi), Hirschmann
available for non-bypass 1 - 17 bar (250 psi) Low JN - No Indicator (plug),
w 24 volt light
applications Collapse No Connector
UK - Electrical 4.9 bar
4 - 207 bar (3000 psi) High KN - Visual 1 bar (15 psi),
(70 psi), Hirschmann
Collapse No Connector
w 115 volt light
LN - Visual 2 bar (30 psi),
HF3P Series 3 No Connector
UL - Electrical 4.9 bar (70 psi),
Port Options Hirschmann w 230 volt
Filter and Element ON - Visual 7.9 bar (115 psi),
BB - G1 to ISO 228 light
Model Code BD - G1-1/2 to ISO 228 No Connector
ME - 1-1/2" SAE 4 bolt Flange RB - Electrical 2 bar (30 psi), 6 Seal Material
Sample model code: Code 61 (M12 x 1.75) Brad Harrison
RH - Electrical 2 bar (30 psi), B - Buna-N
HF3P1SB4LNB2C05 MJ - 2" SAE 4 bolt Flange V - Viton-A
Code 61 (M12 x 1.75) Hirschmann
MU - 2" SAE 4 bolt Flange RJ - Electrical 2 bar (30 psi), 7
Hirschmann w 24 volt Assembly Length
Code 62 (M20 x 2.5)
light mm (inch)
SB - 1.312 - 12 UN SAE-16
RK - Electrical 2 bar (30 psi), 1- 230 (9.1)
str. Thd. (1" tube)
Hirschmann w 115 volt 2- 293 (11.5)
SD - 1.875 - 12 UN SAE-24
Reverse Flow Non-bypass light 4- 414 (16.3)
str. Thd. (1-1/2" tube)
(Valve Option 8) RL - Electrical 2 bar (30 psi), 5- 569 (22.4)
FE - 11/2" SAE 4 bolt Flange
Code 61 (UNC) Hirschmann w 230 volt
8 Element Construction
FJ - 2" SAE 4 bolt Flange light
Code 61 (UNC) TB - Electrical 7.9 bar C - 17 bar (250 psi)
FU - 2" SAE 4 bolt Flange (115 psi), Brad Harrison Low Collapse
Code 62 (UNC) TH - Electrical 7.9 ba H - 207 bar (3000 psi)
(115 psi), Hirschmann High Collapse
4 Valve Options TJ - Electrical 7.9 bar X - no element
(115 psi), Hirschmann
1- Non-Bypass 9 Fluid Cleanliness Rating
w 24 volt light
4- Bypass set at 2.9 bar
(43 psi) cracking pressure TK - Electrical 7.9 bar Target fluid
Reverse Flow Bypass (115 psi), Hirschmann Code cleanliness level
6- Bypass set at 6 bar
(Valve Option 9) w 115 volt light 03 16/14/12 or better
(90 psi) cracking pressure
8- Reverse Flow Valve TL - Electrical 7.9 bar (115 05 18/16/14 or better
psi), 10 20/18/15 or better
Non-Bypass*
Hirschmann w 230 volt
9- Reverse Flow Valve 2.9 20 22/19/16 or better
light
bar (43 psi) Bypass* (C-Pak only)
* Reverse flow bypass available with BD, UB - Electrical 4.9 bar
(70 psi), Brad Harrison XX no element
MU, SD and FU ports only.

128 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Pressure Filters Flows to 454 L/min (120 USgpm)
Pressures to 420 bar (6,000 psi)
HF3P Series V602 * * * * **

1 2 3 4 5 6

V602 Element 1 Filter element 3 Seal material 5 Element construction


Model Code V602 - For use with HF3P, B - Buna-N C - C-Pak (code 03, 05, 10,
series filters V - Viton-A 20)
Sample model code: H - H-Pak (code 03, 05, 10)
2 Element collapse rating 4 Element length
V6021B1C03 6 Fluid cleanliness rating
1 - 17 bar (250 psi) Collapse mm (inch)
4 - 207 bar (3000 psi) High 1- 101 (4) Target fluid
Collapse 2- 203 (8) Code cleanliness level
NOTE: Use 1 only with bypass valve. 4- 330 (13) 03 16/14/12 or better
5- 406 (16) 05 18/16/14 or better
10 20/18/15 or better
Housing Dimensions 166.9 20 22/19/16 or better
mm (inch) (6.57)
60 Inlet & Outlet Porting
(2.36)
30 1 1/2" or 2" SAE
(1.18) flange code 61,
inch or metric

159 57.5 1 1/2" or 2" SAE


(6.26) (2.26) flange code 62,
115 inch or metric
(4.53)

1
/2-20UNF-2B in. X 17 (0.67)deep 4 Places
8.4 Indicator Plug
(0.33)
52 SAE-16, 24, G1 OR G1 1/2
(2.05)

16" Housing

Refer to
Model Code
117
(4.61)

152
(5.98)
427 Clearance required
Drain Plug G 1/2 130.2 (16.8) for element removal
95 (3.74) (5.13)
Clearance required for element removal

Housing/Bypass Valve Flow Data


Housing Bypass Valve
Flow Rate - USgpm Flow Rate - USgpm
53 159 0 10 20 30 40 50 60 70 80 90
2,0 30 11,0 157
147
Pressure drop - psid

Pressure drop - psid

10,0
Pressure drop - bar

Pressure drop - bar

1,5
137
9,0
127
1,0 15
8,0 117
107
0,5 7,0
97
0 6,0 87
0 200 400 600 800 0 50 100 150 200 250 300 350
Flow Rate - L/min Flow Rate - L/min

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 129


Pressure Filters Flows to 454 L/min (120 USgpm)
Pressures to 420 bar (6,000 psi)
HF3P Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9

Element Flow Data

HF3P Filter Elements

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 20

C -pak 1 0.011 (0.589) 0.009 (0.499) 0.005 (0.266) 0.003 (0.153)


2 0.005 (0.288) 0.004 (0.241) 0.002 (0.135) 0.001 (0.076)
4 0.003 (0.175) 0.003 (0.146) 0.001 (0.082) 0.001 (0.046)
5 0.002 (0.132) 0.002 (0.110) 0.001 (0.061) 0.001 (0.034)
H -pak 1 0.017 (0.936) 0.012 (0.659) 0.007 (0.401) xxx
2 0.008 (0.455) 0.006 (0.320) 0.004 (0.195) xxx
4 0.005 (0.273) 0.004 (0.192) 0.002 (0.117) xxx
5 0.004 (0.206) 0.003 (0.145) 0.002 (0.088) xxx
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Sample P Calculation : HF3P1SB4LNB2C05 - Filter assembly having '2' length filter element with micron rating code
'05' at 100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.12 x 0.8/0.9 + 100 x 0.001 x 46/32 x 0.8/0.9
= 0.100 + 0.127
= 0.22 bar

130 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Pressure Filters Flows to 565 L/min (150 USgpm)
Pressures to 410 bar (6,000 psi)
HF3PS Series

Features and Benefits DESIGN SPECIFICATIONS

Beta Ratio: x(c) = 1000 Rated flow: Length 2 265 L/min (70 USgpm)
to ISO 16889 Length 4 454 L/min (120 USgpm)
Length 5 565 L/min (150 USgpm)
Designed to comply with Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water and
ANSI specifications and water-in-oil fluids. Optional seals available for phosphate esters.
ISO cleanliness standards Temp range: -26C to +121C (-15F to +250F)
Visual, and electrical Pressure rating: Operating 310 bar (4500 psi)
indicators with lamp Fatigue 410 bar (6000 psi)
options for system design Material: Head Ductile iron
flexibility Bowl Carbon Steel
Conforms to HF3 Dry weight: Length 2 21,8 kg (48.0 lbs)
automotive specifications (Approximate) Length 4 28,5 kg (62.8 lbs)
Length 5 41,4 kg (91.3 lbs)
Fatigue rated to 6000 psi
for maximum reliability in
rugged applications
Side manifold mounting
for ease of maintenance
in many applications
Multiple filter element
lengths for design flexibility
HF3PS * WS * ** * * * **
High efficiency
replacement elements in
standard configurations 1 2 3 4 5 6 7 8 9
(C-Pak) to meet Target
Cleanliness Levels 1 Filter Series - HF3PS RH - Electrical 2 bar (30 psi), UK - Electrical 4.9 bar
Hirschmann (70 psi), Hirschmann
High collapse elements RJ - Electrical 2 bar (30 psi), w 115 volt light
2 Element Collapse Rating
available for non-bypass Hirschmann w 24 volt UL - Electrical 4.9 bar (70 psi),
applications 1 - 17 bar 17 bar (250 psi) light Hirschmann w 230 volt
Low Collapse RK - Electrical 2 bar (30 psi), light
4 - 207 bar (3,000 psi) High Hirschmann w 115 volt
HF3PS Series Collapse 6
light Seal Material
Filter and Element RL - Electrical 2 bar (30 psi),
3 B - Buna-N
Model Code Port Options Hirschmann w 230 volt V - Viton-A
WS - Subplate mounting light
Sample model code: TB - Electrical 7.9 bar 7 Assembly Length
4 Valve Options (115 psi), Brad Harrison mm (inch)
HF3PS1WS4LNB5C05 1 - Non-Bypass TH - Electrical 7.9 bar 2 - 340 (13.3)
4 - Bypass set at 2.9 bar (115 psi), Hirschmann 4 - 461 (18.1)
(43 psi) cracking pressure TJ - Electrical 7.9 bar 5 - 614 (24.2)
6 - Bypass set at 6 bar (115 psi), Hirschmann
(90 psi) cracking pressure w 24 volt light 8 Element Construction
TK - Electrical 7.9 bar
5 C - 17 bar (250 psi)
Indicator Options (115 psi), Hirshmann
Low Collapse
AN - Visual 4.9 bar (70 psi), w 115 volt light
H - 207 bar (3000 psi)
No Connector TL - Electrical 7.9 bar (115
High Collapse
JN - No Indicator (plug), psi),
X - no element
No Connector Hirschmann w 230 volt
KN - Visual 1 bar (15 psi), light 9 Fluid Cleanliness Rating
No Connector UB - Electrical 4.9 bar
Target fluid
LN - Visual 2 bar (30 psi), (70 psi), Brad Harrison Code cleanliness level
No Connector UH - Electrical 4.9 bar
(70 psi), Hirschmann 03 16/14/12 or better
ON - Visual 7.9 bar (115 psi),
No Connector UJ - Electrical 4.9 bar 05 18/16/14 or better
RB - Electrical 2 bar (30 psi), (70 psi), Hirschmann 10 20/18/15 or better
Brad Harrison w 24 volt light 20 22/19/16 or better
XX no element

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 131


Pressure Filters Flows to 565 L/min (150 USgpm)
Pressures to 310 bar (4,500 psi)
HF3PS Series

V602 * * * * **

1 2 3 4 5 6

V602 Element 1 Filter Element 3 Seal Material 5 Element Construction


Model Code V602 - For use with HF3P, B - Buna-N C - C-Pak (code 3, 5, 10, 20)
HF3PS and OFR30 V - Viton-A H - H-Pak (code 3, 5, 10)
Sample model code: series filters
4 Element Length 6 Fluid Cleanliness Rating
V6021B1C03 2 Element Collapse Rating mm (inch) Target fluid
1 - 17 bar (250 psi) Low 2 - 203 (8) Code cleanliness level
Collapse 4 - 330 (13) 03 16/14/12 or better
4 - 206.9 bar (3,000 PSI) 5 - 406 (16) 05 18/16/14 or better
High Collapse 10 20/18/15 or better
NOTE: Use 1 only with bypass valve.
20 22/19/16 or better

Housing Dimensions
156.5
mm (inch) (6.16)
79.5
29 (3.13) Indicator Plug
(1.14)
23 (0.91)
Thru 4 PL's
7/8-9UNC X 2.50 long
Grade 8 bolts for 140 193
(5.51) 30 (1.18) (7.6)
1.20 long engagement 2 PL'S
are recommended 95
(3.74) 46.5 C'BORE
(4 Req'd) For 40 X 3.5 O-Ring
Torque 185-200 lb-ft flow port dia. Inlet
(250-270 N-m) 6.1
(0.24)
52
110 (2.05)
(4.33) 60
(2.36)
196
(7.72) 112
(4.41) 130.2
L (5.13)

Outlet

117
(4.61)
36 Hex
(1.42)
115 (4.5) Drain Plug G 1/2 152
Clearance for (5.98) 427 (16.8)
element removal Clearance required for
16" HOUSING element removal

132 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Pressure Filters Flows to 565 L/min (150 USgpm)
Pressures to 310 bar (4,500 psi)
HF3PS Series
Flow versus pressure drop:
Flow Data
150 SUS (32 cSt) oil with specific gravity of <0.9

HF3PS Filter Elements Flow Data

'K' factor - bar/lpm (psi/gpm)


ELEMENT TYPE / SIZE MICRON RATING
03 05 10 20

C -pak 1 0.011 (0.589) 0.009 (0.499) 0.005 (0.266) 0.003 (0.153)


2 0.005 (0.288) 0.004 (0.241) 0.002 (0.135) 0.001 (0.076)
4 0.003 (0.175) 0.003 (0.146) 0.001 (0.082) 0.001 (0.046)
5 0.002 (0.132) 0.002 (0.110) 0.001 (0.061) 0.001 (0.034)
H -pak 1 0.017 (0.936) 0.012 (0.659) 0.007 (0.401) xxx
2 0.008 (0.455) 0.006 (0.320) 0.004 (0.195) xxx
4 0.005 (0.273) 0.004 (0.192) 0.002 (0.117) xxx
5 0.004 (0.206) 0.003 (0.145) 0.002 (0.088) xxx
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.

Housing/Bypass Valve Flow Data


Housing Bypass Valve
Flow Rate - USgpm Flow Rate - USgpm
53 106 53 106
1,8 27 16,0
1,5 14,0 203
Pressure drop - psid

Pressure drop - psid


Pressure drop - bar

Pressure drop - bar

12,0
1,2 17
10,0 145
0,9 8,0
6,0 87
0,6 9
4,0
0,3 2,0
0 0
0 100 200 300 400 500 0 100 200 300 400
Flow Rate - L/min Flow Rate - L/min

Sample P Calculation : HF3PS1WS4LNB5C05 - Filter assembly having '5' length filter element with micron rating
code '05' at 200 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.28 x 0.8/0.9 + 200 x 0.002 x 46/32 x 0.8/0.9
= 0.250 + 0.51
= 0.76 bar

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 133


Pressure Filters Flows to 100 L/min (25 USgpm)
Pressures to 100 bar (1,450 psi)
DMP DIN Series
Filters

Features and Benefits DESIGN SPECIFICATIONS

Beta Ratio: x(c) = 1000 Rated flow: 040 40 L/min (11USgpm)


063 63 L/min (17USgpm)
to ISO 16889 100 100 L/min (26USgpm)
Designed to Comply with Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
DIN 24550 specifications Optional seals available for phosphate esters
Fatigue rated to 100 Bar Temp range: -10C to + 100C (+14F to +212F)
Visual and electrical Pressure rating: Fatigue 100 bar (1450 psi)
indicators with light Material: 040/063 Aluminum
options for system design 100 Aluminum and Steel
flexibility Dry weight: 040 1,8kg (4.0 lbs)
063 1,8kg (4.0 lbs)
High efficiency six layer 100 4,2kg (9.3 lbs)
media elements
Bypass and non-bypass
options available

DMP * *** ** * ** * * **

1 2 3 4 5 6 7 8 9

DMP Series Filter 1Filter Series 5


Valve Options 8 Element Construction
DMP - DIN Medium Pressure 1 - Non-Bypass C - Standard Construction
Sample model code: 6 - Bypass set at 7 bar (100 H - High Collapse
2 Element Collapse Rating psi) cracking pressure X - no element
DMP1100BD6ANBC06
1 - 30 bar (435 psi)
6 Indicator Options 9 Fluid Cleanliness Rating
Low Collapse
4 - 160 bar (2,320 psi) AN - Visual 5 bar (70 psi), Target fluid
High Collapse No Connector Code cleanliness level
JN - No Indicator, No 03 16/14/12 or better
3 Nominal Size Connector 06 18/16/14 or better
040 - 40 L/min (10.6 USgpm) TB - Electrical 5 bar (70 psi), 10 20/18/15 or better
063 - 63 L/min (16.6 USgpm) Brad Harrison Connector
TH - Electrical 5 bar (70 psi), 25 22/19/16 or better
100 - 100 L/min (26.4 USgpm)
Hirschmann XX no element
4 Port Size
7 Seal Material
BB - G 1/2 (Length 040 only)
BC - G 3/4 (Length 063 only) B - Buna-N
BD - G 1 (Length 100 only) V - Viton-A

134 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Pressure Filters Flows to 100 L/min (25 USgpm)
Pressures to 100 bar (1,450 psi)
DMP DIN Series
Filters

VDP *** * * **

1 2 3 4 5

Element model code 1 Filter Element 3 Seal Material 5 Fluid Cleanliness Rating
VDP - DIN Standard Element B - Buna-N Target fluid
Sample model code: V - Viton-A Code cleanliness level
2 Nominal Size 03 16/14/12 or better
VDP160BC06 4
040 - 40 L/min (10.6 USgpm) Element Construction 06 18/16/14 or better
063 - 63 L/min (16.6 USgpm) C - Standard Construction 10 20/18/15 or better
100 - 100 L/min (26.4 USgpm) H - High Collapse 25 22/19/16 or better

Dimensions DRT Series

B1
Dimensions in mm B2
45

15
40

Port Size
See Chart
h2
h1

68
Remove Elemant

Drain Plug
H3 Minimum

(100 size only)


Clearance to

M-6
56
83
50

Outlet Inlet
32

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 135


Pressure Filters Flows to 100 L/min (25 USgpm)
Pressures to 100 bar (1,450 psi)
DMP DIN Series
Filters
Housing and Element
Flow Data

DMP 040, 063, 100 Series Housing Data

0.6

0.5

p [bar]
0.4
TYPE PORT SIZE B1 B2 H1 H2 H3

DMP 040 G 1/2 92 91 146 75 0.3


DMP 063 G 3/4 92 152 207 75
DMP 100 G1 160 246 301 85 0.2

0.1
0 10 20 30 40 50 60 70 80 90 100
Flow rate [l/min]

DMP Series Element Flow Data


Element size 100 3m
2.5

2.0 6m
p [bar]

1.5
10m
1.0 25m

0.5

0.0
0 50 100 150 200 250 300
flow rate [l/min]

Element size 40 Element size 63


2.0 2.0
1.8 3m 1.8
1.6 1.6
1.4 1.4
6 m 3m
p [bar]

p [bar]

1.2 1.2
1.0 1.0
0.8 0.8 6 m
10 m
0.6 0.6
25 m 10 m
0.4 0.4 25 m
0.2 0.2
0.0 0.0
0 15 30 45 60 75 0 15 30 45 60 75
flow rate [l/min] flow rate [l/min]

136 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Pressure Filters Flows to 400 L/min (106 USgpm)
Pressures to 400 bar (5,801 psi)
DHP DIN Series
Filters

Features and Benefits DESIGN SPECIFICATIONS

Beta Ratio: x(c) = 1000 Rated flow: 063 63L/min (16.6USgpm)


100 100L/min (26.4USgpm)
to ISO 16889 250 250L/min (66.0USgpm)
Designed to Comply with 400 400L/min (105.7USgpm)
DIN 24550 specifications Housing & Element Compatibility: Compatible with most petroleum oil, water glycol, and oil in-water fluids.
Fatigue rated: 063, 100, Optional seals available for phosphate esters.
and 250 size:(400 bar) Temp range: -10C to + 100C (+14F to +212F)
400 size: (210 bar) Pressure rating: Operating 063, 100, 250 400 bar (5800PSI)
Visual and electrical 400 210 bar (3045PSI)
indicators with light Material: Nodular Iron and Steel
options for system Dry weight: 063 6.0kg (13.2lbs.)
design flexibility (Approximate with element) 100 7.5kg (16.5lbs.)
250 13.0kg (28.6lbs.)
High efficiency six layer 400 28.0kg (61.7lbs.)
media elements
Bypass and non-bypass
options available

DHP * *** ** * ** * * **

1 2 3 4 5 6 7 8 9

DHP Series Filter 1 Filter Series 5 Valve Options 8 Element Construction


Model Code DHP - DIN High Pressure 1 - Non-Bypass C - Standard Construction
6 - Bypass set at 7 bar (100 H - High Collapse Construction
Sample model code: 2 Element Collapse Rating psi) X - no element
1 - 30 bar (435 psi) Low cracking pressure
DHP1100BD6ANBC06 9 Media Code
Collapse
6 Indicator Options
4 - 160 bar (2320 psi) High 03 - 16/14/12 or better
Collapse AN- Visual 5 bar (70 psi), 06 - 18/16/14 or better
No Connector 10 - 20/18/15 or better
3 Nominal Size JN- No Indicator, 25 - 22/19/16 or better
063 - 63L/min (16.6USgpm) No Connector XX - no element
100 - 100L/min (26.4USgpm) TB- Electrical 5 bar (70 psi),
250 - 250L/min (66.0USgpm) Brad Harrison Connector
400 - 400L/min (105.7USgpm) TH- Electrical 5 bar (70 psi),
Hirschmann
4 Port Size
7 Seal Material
PORT FILTER SIZE
TYPE SIZE 63 100 250 400 B - Buna-N
BC G 3/4 V - Viton-A
Viton is a registered trademark of E.I. DuPont
BD G1
BE G 1-1/2
BK DN38

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 137


Pressure Filters Flows to 400 L/min (106 USgpm)
Pressures to 400 bar (5,801 psi)
DHP DIN Series
Filters

Dimensions DHP 063, 100 Series

B1

B2

45

12
40

D1
Port Size
See Chart
h2

h1

65
85 Minimum Clearance to

Drain Plug
Remove Element

M-6
56
89

156

Outlet Inlet

32

138 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Pressure Filters Flows to 400 L/min (106 USgpm)
Pressures to 400 bar (5,801 psi)
DHP DIN Series
Filters

Dimensions DHP 250 and 400 Series


B1
Port Size
See Chart
45
H2

H1

116
105 Minimum Clearance to

Drain Plug
Remove Element

M12
11 5
11 3
15 7

Inlet

Connection for Indicator

Outlet
60

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 139


Pressure Filters Flows to 400 L/min (106 USgpm)
Pressures to 400 bar (5,801 psi)
DHP DIN Series
Filters

DHP 063, 100 Series Housing Data

Filter Housing Flow Data DHP 063/100


0.6
Flow versus pressure drop:
32 cSt oil with specific gravity of 0.9 0.5
(See page 5 for specific gravity corrections for pressure drop.)

p [bar]
0.4
TYPE PORT SIZE B1 B2 D1 H1 H2
DHP 063 G 3/4 150 146 215
0.3
DHP 100 G1 96 50 236 305

0.2

0.1
0 10 20 30 40 50 60 70 80 90 100
Flow rate [l/min]

DHP 250, 400 Series Housing Data

Filter Housing Flow Data DHP 250 /400


Flow versus pressure drop: 0.30

32 cSt oil with specific gravity of 0.9 0.25


(See page 5 for specific gravity corrections for pressure drop.)
0.20
TYPE PORT SIZE B1 H1 H2
p [bar]

DFN 250 G 1 1/2 167 229 330


0.15
DFN 400 DN 38* 158 379 480
* Flange SAE 1 1/2, 3000 PSI (210 bar)
0.10

0.05

0.00
0 40 80 120 160 200 240
Flow rate [l/min]

140 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Pressure Filters
DHP DIN Series
Filters

Element Model Code VDP *** * * **


(For use in DHP, DMP, and
1 2 3 4 5
DLR Series Housings)

1
Filter Element 3 Seal Material 5 Media Grade
VDP - DIN Standard Element B - Buna-N 03 16/14/12 or better
Sample model code: V - Viton-A 06 18/16/14 or better
2 Nominal Size Viton is a registered trademark of E.I. DuPont 10 20/18/15 or better
VDP063BC06
063 - 63L/min (16.6USgpm) 25 22/19/16 or better
4 Element Construction
100 - 100L/min (26.4USgpm)
250 - 250L/min (66.0USgpm) C - Standard Construction
400 - 400L/min (105.7USgpm) H - High Collapse Construction

VDP Series
2
Element size 063 Low Collapse 2.5 Element size 063 High Collapse
Element Flow Data 1.8 3m
1.6 2
Flow versus pressure drop: 32 cSt
oil with specific gravity of 0.9
1.4

p [bar]
p [bar]

1.2 1.5
3m 6m
1
(See page 6 for viscosity 0.8 6m 1 10m
corrections for pressure drop.) 0.6 25 m
0.4 10m 0.5
0.2 25 m
0 0 15 30 45 60 75
0 3015 45 60 75
3 Element size 400 Low Collapse flow rate [l/min] flow rate [l/min]
Element size 100 Low Collapse Element size 100 High Collapse
2.5 2.5 3m 4
3m
3m 3.5
p [bar]

2 2
3
p [bar]

p [bar]
1.5 6 m 1.5 2.5
6m 6m
1 10m 2
25m 1 1.5 10m
0.5 10m
25 m 1 25m
0.5
0 0.5
0 50 100 150 200 250 300 350 400 450 500
flow rate [l/min] 0 0
0
20 40 60 80 100 120 140 160 180 200 020 40 60 80 100 120 140 160 180 200
flow rate [l/min] flow rate [l/min]
Element size 250 Low Collapse Element size 250 High Collapse
3 Element size 400 High Collapse 3 3
2.5 2.5 3m
2.5 3m
3m
p [bar]
p [bar]

2 2
p [bar]

2
6m
1.5 6m 1.5 6m 1.5 10m
10m 1 10m 1
1 25m 25m
25 m 0.5 0.5
0.5
0 0
0 0 50 100 150 200 250 300 350 400 450 500 0 50 100 150 200 250 300 350 400 450 500
0 50 100 150 200 250 300 350 400 450 500 flow rate [l/min] flow rate [l/min]
flow rate [l/min]

Sample P Calculation : DHP1100BC4ANBC06 - Filter assembly having filter element with micron rating code '06' at
70 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.35 x 0.8/0.9 + 0.4 x 46/32 x 0.8/0.9
= 0.310 + 0.51
= 0.82 bar

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 141


Off-Line Filters

General Data
Off-line filtration systems (also referred to as a kidney is optimized, heat exchangers can be used within the
loops or recirculation loops) are typically found in off-line system to achieve the necessary operating
variable volume pump systems where system filters parameters. The off-line system can also be used as
do not see continuous flow or where the return flow the make-up point to add fluid to the system and
volume makes a return filter impractical. These help ensure that only clean fluid is introduced to
systems typically consist of a separate pump and filter the system. The off-line system can also be shut-
plumbed to the reservoir along with associated down
components to provide a continuous recirculating flow to change filter elements without securing the main
of fluid from the reservoir through the filter and back system.
to the reservoir.
Rarely can an off-line filtration system be used as the
There are many advantages to incorporating an off- sole contamination control solution. It is normally
line filtration package. Because the system is at a low used to supplement the main system filters and a
pressure and the flow is continuous with little or no typical recommended size for the off-line system flow
flow surges, economical low pressure filter housings rate is approximately 20% of the total main system
can be used. In addition, because temperature control volume.
is necessary to ensure that the components see the
In addition to hydraulic systems, off-line filtration
proper viscosity and that the oxidation rate of the fluid
systems can be used on gearbox applications to clean
the fluid where there are no other lubrication circulation
systems present.

Applications
Pulp and paper mill
equipment
Large central hydraulic
power units
Injection molding
equipment
Stamping presses
Extrusion machines

142 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Off-Line Filters Flows to 15 L/min (4 USgpm)
Pressures to 3.5 bar (50 psi)
EPHHF
Eaton Portable
Handheld

Features and Benefits DESIGN SPECIFICATIONS

Ideal for maintaining Rated flow: 15 L/min (4 USgpm)


construction, agricultural Fluid Compatibility: Compatible with petroleum based fluids
machinery, off-highway Material: Aluminum
trucks and vehicles
Temp range: Up to 80C (180F)
Equally useful for
Dry weight: (Approximate) 12.5 kg (27.5 lbs)
servicing a wide variety of
industrial equipment Pressure rating: 3.5 bar (50 psi)

Incorporates a highly
efficient spin-on filter
element
Relief valve housing
Static pressure gauge
clogging indicator
Element easily replaced TECHNICAL DATA
with stap wrench Fluid Compatibility: Petroleum based oils
Nominal Flow: 4 GPM/ 15 l/min
Applications Maximum Oil Temperature: 80C (180F)
The portable filtration unit Viscosity Range: 40 to 2300 SUS 5-500 mm2/sec
is a compact filter/pump
Max. Operating Pressure: 50 psi/3.5 bar
device used for
transferring and filtering Weight: 27.5 lb/12.5 kg
hydraulic fluids Electrical Motor: 110 VAC (0.25 HP/0.18 KW)
Removing water from oil Dimensions: Length 3660mm (14.41")
Width 3650mm (14.37")
Changing oil in hydraulic
Height 3650mm (14.37")
systems
Note: V0211B1 series Elements ordered separately.
Filling hydraulic systems See OFRS60 Catalog pages for more information on V0211B1 series elements.
with filtered oil
Off-line filtration of
hydraulic systems with
inadequate filtering
capacity

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 143


Off-Line Filters Flows to 19 L/min (5 USgpm)
Pressures to 4 bar (65 psi)
CC OFRS 60
Clean Cart

Features and Benefits DESIGN SPECIFICATIONS

Choice of 3, 5, 10, or 20 Rated flow: CCOFRS60 05 part #5003889 19 L/min (5 USgpm)


m absolute rated filter CCOFRS60 10 part #5003912 38 L/min (10 USgpm)
elements, all with Beta Fluid Compatibility: Compatible with petroleum based fluids
Ratios >_ 200 for maximum Material: Steel
efficiency
Temp range: +10 to +54C (+50 to +130F)
10m of water removal
Dry weight: (Approximate) 52 kg (115 lbs)
elements with capacity of
0.45 quarts of water each Pressure rating: 4.5 bar (65 psi)

Welded tubular steel


frame for durability
Dirt-tolerant, self-priming
vane pump
Compact design, balanced
weight, and large tires for TECHNICAL DATA
easy handling Fluid Compatibility: Mineral oil, including lube and fuel oil.
Spiral-reinforced, clear, 10 Note: Not allowed for use on water based fluids.
PVC hoses with 20" steel Motor: 1750rpm, 1/2 HP (5 USgpm), 3/4 HP (10 USgpm) 110V Single Phase
end wands Electric Cord: 20 long
520m cleanable strainer Pump: Direct drive vane, 5 or 10 gpm, self-priming
before the pump
Clogging Indicators: Color coded static pressure gauge
Applications Strainer: Stainless steel, 520 m
Hoses: Spiral-reinforced clear PVC, standard 10 length, 20" steel wands
Filter particles and/or water
from new oil while filling a Dimensions: Height 51"
reservoir Width 21.5"
Length 27.5"
Recirculate and filter oil Weight of Cart: 115 lbs
during start-up, when
Operating Range: Fluid temperature +10 to +54C (+50 to +130F)
contamination is often Pressure to 4 bar (65 psi)
heaviest Viscosity 100 - 500 SUS
Recirculate and filter oil Note: V0211B1 series or V0211B2 series Elements ordered separately.
off-line on systems with See OFRS60 Catalog pages for more information on V0211B1 or V0211B2 series elements.
inadequate filtering
capacity
Empty a storage tank or
reservoir
Ideal for use in industrial
plants and in other
demanding applications
because of their efficiency,
capacity, and durability

144 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Off-Line Filters Flows to 19 L/min (4.9 USgpm)
Pressures to 3 bar (45 psi)
OLF15V
Off-Line Filtration
Package

Features and Benefits DESIGN SPECIFICATIONS

Ultra high efficiency Rated flow: 19 L/min (5 USgpm)


membrane element Fluid Compatibility: Compatible with petroleum based fluids
technology Beta2>1000 Material: Aluminum
Compact design Temp range: -20 to +40C (-4 to +104F)
Water removal elements Dry weight: (Approximate) 11 kg (24.3 lbs)
available Pressure rating: 3 bar (45 psi)
20 micron element
TECHNICAL DATA
available for gear box
applications Operating Range
High capacity elements Viscosity: 3000 SUS
(200 grams) Operating Pressure: 3 bar (45 psi)
Single Vane pump- 5 Suction Pressure: -0.4 bar (11" Hg) max
USgpm (19 L/min)
capacity at 3 bar Inlet Pressure 10 bar (145 psi) min
Driven by AC motor Fluid Temperature: 0 to +80C (+32 to +175F)
Ambient Temperature: -20 to +40C (-4 to +104F)
Applications
Seals: Buna-N
The OLF 15V is ideal for
systems in which the Maximum Flow Rate: 18.5 L/min (4.9 USgpm)
ingression rate of Elements
contamination is relatively
low. Applications well suited Dirt Holding Capacity: 200g ISO MTD, or approximately 0.45lbs
for the new product include: Water Retention: (P = 2.5 bar [36 psi]):
Plastic injection molding Approximately 0.5 quarts (0.5 liters)

2 > 1000 (absolute value)


systems
Beta Ratio:
In-plant press systems
The 20-micron element is Maximum P: 3 bar (45 psi)
normally more than Dimensions: Length 538mm (21.2")
adequate for gearbox Width 168mm (6.61")
OLF 15V * ******** ** ** Height 109mm (7.48")
applications.

1 2 3 4 5 6

OLF15V Off-Line 4 Filter Element 6 Indicator Options


Filtration Package
V15BMC02 - 2 Micron filter JN - No indicator (plug),
Model Code element No Connector
V15BMW02 - 2 Micron filter LN - Visual 2 bar (30 PSI),
1 OLF- Filtration Unit with water removal element No Connector
V15BMC20 - 20 Micron filter
2 15V - (19 L/min) Vane element RB - Electrical 2 bar (30 PSI),
Pump V15BMW20 - 20 Micron filter Brad Harrison
with water removal element RH - Electrical 2 bar (30 PSI),
3 Motor Voltage Hirschmann
5 Port Options
K - 115 Volt AC, 1 Phase, RJ - Electrical 2 bar (30 PSI),
60Hz SB - 1-5/16-12 (SAE-16) Hirschmann with 24 Volt
BB - G1 BSPP thread light
M - 220 Volt AC, 1 Phase,
50Hz RK - Electrical 2 bar (30 PSI),
Hirschmann with 115
N - 220/440 Volt AC, 3 Phase,
Volt light
50 or 60Hz
RL - Electrical 2 bar (30 PSI),
Hirschmann with 230 Volt
light
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 145
Accessories
Fluid Sampling

Features and Benefits


Remove metal dustcover on
discharge port. Discharge
approximately 200 ml of oil
to flush valve by turning
knurled knob 1/4 turn to the
right. Dispose of this sample
in the appropriate manner.
Locate clean oil sample
bottle under discharge port.
Turn knurled knob 1/4 turn
to the right until bottle is
filled to the desired level. 0-50 psi 50-300 psi
The knob can be backed off
PART NUMBER INLET PORTS PART NUMBER INLET PORTS
to throttle the rate of flow.
When bottle is filled let go FD15-1026-04 1
/4" NPTF FD15100002 1
/8" NPTF
of the knurled knob, the FD15-1025-04 7
/16-20 Male ORB FD15100004* 1
/4" NPTF
valve will close automatically. As required in MIL-V-81940/2-1 this valves FD15100204 7
/16-20 Male ORB
Replace metal dustcover flow rate is between 100 and 1500 milliliters *The 1/4" NPTF version is qualified to MIL-V-
wrench tight. For more per minute at pressures from 050 psi. (MIL- 81940/2-1 and its performance is representative
information see Fluid V-81940/2-1 applies only to pressures from of the other inlet port configurations listed
50300 psi.) above. QPL-81940-9 6-5-89
Analysis section at front of
this catalog where sample
DESIGN SPECIFICATIONS
kit options are listed.
Construction: Corrosion resistant plated steel with brass internal
Applications components and Buna-N seal
Engine oil, lubricating oil, Operating Temp range: -53C to +135C (-65F to +275F)
transmission fluid and Minimum Burst Pressure: 1200psi
hydraulic fluids in mobile Minimum Particle Restriction: 500 microns
construction equipment,
military vehicles, trucks and Maximum Torque to Operate: 10 in. lbs.
stationary equipment. Note: This valve is not intended for aerospace applications
For best results, Eaton FD15
Oil Sampling Valves should
be installed in dynamic fluid
lines in low pressure and
return lines. If only one
sampling point can be
chosen, it should be in the
return line, upstream of any
return line filter. This will
insure a representative
sample of all components in
the fluid system for their
present condition.

INDICATOR OPTIONS (3,000 PSI - USE WITH FILTER MODELS HV6R, HV3R)

Coupling Thread Dimension Data Part No.


Size Size (P) A B C 1 2 3 Buna-N
1
/8-27 2.42 1.00 1.30 .69 .38 FD15-1000-02
1
/4-18 2.56 1.00 1.30 .59 .38 FD15-1000-04
7
/16-20 2.79 1.00 1.30 .69 .38 .56 FD12-1002-04
1
/4-18 2.56 1.00 1.30 .69 .38 FD15-1026-04
7
/16-20 2.79 1.00 1.30 .69 .38 .56 FD12-1025-04

146 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Accessories
Differential
Indicators
DESIGN SPECIFICATIONS

Material: PV/PE Series Aluminum


PHV/PHE Series Stainless Steel
Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
Optional seals available for phosphate esters.
Installation Torque: PV/PE Series 33 Nm (24 lbs-ft)
PHV/PHE Series 100 Nm (74 lbs-ft)
Temp range: -26C to +120C (-15F to +250F)
Switch Rating (all models): 3A@24VDC
5A@250VAC
Dry weight: (Approximate) PV 55g (0.1lbs)
PHV 110g (0 2lbs)
PE 150g (0.3lbs)
PHE 250g (0.6lbs)
Pressure rating: PV/PE Series 210 bar (3000PSI)
PHV/PHE Series 420 bar (6000PSI)

** ** V * ***

1 2 3 4 5

Indicator Model Code 1 Indicator type and 3 Seal material


pressure rating V - Viton-A
PV - visual 210 bar (3000psi)
PE - electrical 210 bar (3000psi) 4 Connector
PHV- visual 420 bar (6000psi) B - Brad Harrison 5 Pin
PHE - electrical 420 bar (6000psi) H - Hirschmann
N - None (use with PV indicators)
2 Pressure setting
1B - 1 bar (15psid) 5 Light option
2B - 2 bar (30psid) L24 - 24 Volt Lamp
5B - 5 bar (75psid) L115 -115 Volt Lamp
8B - 8 bar (115psid) L230 -230 Volt Lamp

INDICATOR OPTIONS (3000 PSI - USE WITH FILTER MODELS HV6R, HV3R)

Filter Assembly
Description Model Code Letters
POPUP VISUAL 15 psi PV 1B VN KN
POPUP VISUAL 30 psi PV 2B VN LN
POPUP VISUAL 70 psi PV 5B VN AN
BRAD HARRISON 5 PIN ELECTRICAL 15 psi PE 1B V B QB
BRAD HARRISON 5 PIN ELECTRICAL 30 psi PE 2B V B RB
BRAD HARRISON 5 PIN ELECTRICAL 70 psi PE 5B V B UB
HIRSCHMANN ELECTRICAL 15 psi PE 1B V H QH
HIRSCHMANN ELECTRICAL 30 psi PE 2B V H RH
HIRSCHMANN ELECTRICAL 70 psi PE 5B V H UH
HIRSCHMANN VISUAL ELECTRICAL 15 psi - L24 PE 1B V H L24 QJ
HIRSCHMANN VISUAL ELECTRICAL 30 psi - L24 PE 2B V H L24 RJ
HIRSCHMANN VISUAL ELECTRICAL 70 psi - L24 PE 5B V H L24 UJ
HIRSCHMANN VISUAL ELECTRICAL 15 psi - L115 PE 1B V H L115 QK
HIRSCHMANN VISUAL ELECTRICAL 30 psi - L115 PE 2B V H L115 RK
HIRSCHMANN VISUAL ELECTRICAL 70 psi - L115 PE 5B V H L115 UK
HIRSCHMANN VISUAL ELECTRICAL 15 psi - L230 PE 1B V H L230 QL
HIRSCHMANN VISUAL ELECTRICAL 30 psi - L230 PE 2B V H L230 RL
HIRSCHMANN VISUAL ELECTRICAL 70 psi - L230 PE 5B V H L230 UL

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 147


Accessories
Differential INDICATOR OPTIONS (6,000 PSI - USE WITH FILTER MODELS HF2P, HF3P, HF3PS, HF4, MF2P)

Indicators Filter Assembly


Description Model Code Letters
Popup Visual 30psi PHV 2B VN LN
Popup Visual 70 Psi PHV 5B VN AN
Popup Visual 115 Psi PHV 8B VN ON
Brad Harrison 5 Pin Electrical 30 Psi PHE 2B V B RB
Brad Harrison 5 Pin Electrical 70 Psi PHE 5B V B UB
Brad Harrison 5 Pin Electrical 115 Psi PHE 8B V B TB
Hirschmann Electrical 30 Psi PHE 2B V H RH
Hirschmann Electrical 70 Psi PHE 5B V H UH
Hirschmann Electrical 115 Psi PHE 8B V H TH
Hirschmann Visual Electrical 30 Psi - L24 PHE 2B V H L24 RJ
Hirschmann Visual Electrical 70 Psi - L24 PHE 5B V H L24 UJ
Hirschmann Visual Electrical 115 Psi - L24 PHE 8B V H L24 TJ
Hirschmann Visual Electrical 30 Psi - L115 PHE 2B V H L115 RK
Hirschmann Visual Electrical 70 Psi - L115 PHE 5B V H L115 UK
Hirschmann Visual Electrical 115 Psi - L115 PHE 8B V H L115 TK
Hirschmann Visual Electrical 30 Psi - L230 PHE 2B V H L230 RL
Hirschmann Visual Electrical 70 Psi - L230 PHE 5B V H L230 UL
Hirschmann Visual Electrical 115 Psi - L230 PHE 8B V H L230 TL
Indicator Plug 3040056

Differential Indicator Dimensional Schematics

PE * B V B PV * B VN
PHE * B V B
58 27
(2.28) (1.06)

A WHITE 1

3 RED
GREEN 2
P
1
2 ORANGE 34
27 HEX
BLACK 5
63.5 (1.06)
(2.50)
B
62.5 29
(2.46) 100.6 Schematic
(1.14)
(3.96)

G 1/2

27 G 1/2
(1.06)

PE * B V H PE * B V H L * *
PHE * B V H PHE * B V H L * *
70
(2.76)
51 A )
(2.00) 3
A ) 3P )
3 ) 1
3 1 )
P
2 )
1 1 2 )
) B
2 2
B )
60.2 111.4 Schematic
70
(2.76) 108.1 (2.37) (4.39)
(4.26) Schematic

27 G 1/2
27 G 1/2 (1.06)
(1.06)

148 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Accessories
Static
Indicators

PLV 2B V H L24

1 2 3 4 5

Indicator Model Code 1Indicator type and 3 Seal Material


pressure rating V - Viton-A
PLV - Visual
PLE - Electrical 4 Connector
SLV - Visual B - Brad Harrison 5 Pin
SLE - Electrical N - Hirschmann
2 Pressure setting H - None
1B - 1 bar (15psid) 5 Light Options
2B - 2 bar (30psid)
5B - 5 bar (75psid) L24 - 24 Volt Lamp
1.4B - 1.4 bar (20psid) L115 - 115 Volt Lamp
L230 - 230 Volt Lamp
N - None

INDICATORS FOR ORFM


INDICATORS FOR ORFM SERIES EATON SERIES-LENGTH 5-7; EATON
LENGTH 1-4 & HF4RT SERIES MODEL CODE ORF1300 SERIES & DRT SERIES MODEL CODE

KN Visual, 15 PSI, No connector PLV 1B V N N Visual, 15 PSI, No connector SLV 1B V N N


MH Electrical, 15 PSI, Hirschmann PLE 1B V H N Electrical, 15 PSI, Hirschmann SLE 1B V H N
MB Electrical, 15 PSI, Brad Harrison PLE 1B V B N Electrical, 15 PSI, Brad Harrison SLE 1B V B N
MJ Electrical, 15 PSI, Hirschmann w 24 Volt light PLE 1B V H L24 Electrical, 15 PSI, Hirschmann w 24 Volt light SLE 1B V H L24
MK Electrical, 15 PSI, Hirschmann w 115 Volt light PLE 1B V H L115 Electrical, 15 PSI, Hirschmann w 115 Volt light SLE 1B V H L115
ML Electrical, 15 PSI, Hirschmann w 230 Volt light PLE 1B V H L230 Electrical, 15 PSI, Hirschmann w 230 Volt light SLE 1B V H L230
LN Visual, 30 PSI, No connector PLV 2B V N N Visual, 30 PSI, No connector SLV 2B V N N
RH Visual, 30 PSI, Hirschmann PLE 2B V H N Visual, 30 PSI, Hirschmann SLE 2B V H N
RB Electrical, 30 PSI, Brad Harrison PLE 2B V B N Electrical, 30 PSI, Brad Harrison SLE 2B V B N
RJ Electrical, 30 PSI, Hirschmann w 24 Volt light PLE 2B V H L24 Electrical, 30 PSI, Hirschmann w 24 Volt light SLE 2B V H L24
RK Electrical, 30 PSI, Hirschmann w 115 Volt light PLE 2B V H L115 Electrical, 30 PSI, Hirschmann w 115 Volt light SLE 2B V H L115
RL Electrical, 30 PSI, Hirschmann w 230 Volt light PLE 2B V H L230 Electrical, 30 PSI, Hirschmann w 230 Volt light SLE 2B V H L230
AN Visual, 70 PSI, No connector PLV 5B V N N Visual, 70 PSI, No connector SLV 5B V N N
UH Electrical, 70 PSI, Hirschmann PLE 5B V H N Electrical, 70 PSI, Hirschmann SLE 5B V H N
UB Electrical, 70 PSI, Brad Harrison PLE 5B V B N Electrical, 70 PSI, Brad Harrison SLE 5B V B N
UJ Electrical, 70 PSI, Hirschmann w 24 Volt light PLE 5B V H L24 Electrical, 70 PSI, Hirschmann w 24 Volt light SLE 5B V H L24
UK Electrical, 70 PSI, Hirschmann w 115 Volt light PLE 5B V H L115 Electrical, 70 PSI, Hirschmann w 115 Volt light SLE 5B V H L115
UL Electrical, 70 PSI, Hirschmann w 230 Volt light PLE 5B V H L230 Electrical, 70 PSI, Hirschmann w 230 Volt light SLE 5B V H L230

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 149


Accessories

Electrical Pressure Switch Hirschmann Connector

77
(3.03)

75
(2.95)
105.8
(4.16)

30 1/8 BSP
(1.18)

HOUSING PART NUMBER

DRT 3039708 Electrical Switch 30 psi Hirschmann Connector

Gauge 0-10 Bar Gauge

3
2
0 10
bar

50

30.5
(1.20) 46.7
(1.84)

1/8" BSP
13.97
(0.55)

HOUSING PART NUMBER

DRT 3039703 Gauge 0 - 10 Bar


Note: Gauges indicate pressure in both bar and psi

150 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Accessories
Indicator Switch

Schematic Wiring Diagram Hirschmann (DIN 43650 Type AM) Receptacle


GD
Note: The female connector is to be 1 2
furnished by the customer. WHITE 3

Note: When fitting indicator, torque BLACK


to 41-47 Nm. PIN
ARRANGEMENT
ELECTRICAL

Switch: SPDT NO
GD GREEN
Rating: 7 amps, resistive C
4 amps, inductive 1 2
TO
2 amps, lamp load NC RED 3 SYSTEM
@28 VDC, 115 VAC 60 Hz
& 220 VAC 50 Hz or 60 Hz

Brad Harrison (41512) Receptacle


GD
1 5
WHITE
2 4
BLACK
3
ORANGE

PIN
ARRANGEMENT
NO 1 5
TO
C
SYSTEM
2 4
NC RED
3 GREEN

Electrical Pressure Switch


HOUSING PART NUMBER

HF4RT 3039705 Electrical Switch 15 psi Brad Harrison Connector


3039707 Electrical Switch 15 psi Hirshmann Connector
HF4RT 3039706 Electrical Switch 30 psi Brad Harrison Connector
3039708 Electrical Switch 30 psi Hirshmann Connector

Hirshmann Connector Brad Harrison Connector

70
77 (2.76)
(3.03)

75 75
(2.95) (2.95)
105.8 105.8
(4.16) (4.16)

30 1/8 NPT
(1.18) 30 1/8 NPT
(1.18)

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 151


Accessories
Gauge

HOUSING PART NUMBER 0-4 Bar (0-60 PSI) Gauge 0-10 Bar (0-160 PSI) Gauge
HF4RT 3039703 Gauge 0-160 psi (use with 43 psi Bypass Valve)
3039704 Gauge 0-60 psi (use with 25 psi Bypass Valve)
25
Note: Gauges indicate pressure in both bar and psi 20 3
2
0 PSI60 0 10
bar

50 50

30.5 30.5
(1.20) (1.20)
46.7 46.7
(1.84) (1.84)

1/8" NPFT 1/8" NPFT


13.97 13.97
(0.55) (0.55)

Mounting Bracket 65 280


(11.0)
HV6R Housing (2.6)
15 140 126
(0.6) (5.5) (5.0)
mm (inch)
40 (1.6) 15
Order part number 3039702 (0.6) 232
18 (9.1")
(0.7")

14
(0.6) 172
(6.8)
280
(11)

290
(11.4")

152 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Accessories
Gauge

Weld Flange for HF4RT


Order part number P-232964-1

D DIMENSIONS

A Housing A B C D E
diameter length
C HL 15, HL 16 7/16- 20 UNF 127,0 181,0 7/16 - 20 UNF x 0.75 12,7
B P-232964-01 thru (4) on 6.25 dia. (5.00) (7.12) Recommended bolts (0.50)
BC equally spaced

Seal Kits SERIES SEAL SEAL KIT


TYPE PART #

Note HV6R Buna-N 3039688


Seal kits include all soft Viton-A* 3039689
goods to fully service a unit. HV3R Buna-N 3039690
Viton-A 3039691
HF4RT Buna-N 3039692
Viton-A 3039693
HF2P Buna-N 3039694
Viton-A 3039695
HF3P Buna-N 3039696
Viton-A 3039697
HF3PS Buna-N 3039698
Viton-A 3039699
HF4P Buna-N 3039700
Viton-A 3039701
OFR60/ Buna-N 590021
120 Viton-A 591761
(Bowl seal only)
OFR15/ Buna-N 226214
30 Viton-A 262422
(Bowl seal only)

* Viton is a registered trademark of E.I. Dupont

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 153


Notes

154 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007


Notes

EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 155


Eaton Eaton Eaton
Hydraulics Operations USA Hydraulics Operations Europe Hydraulics Operations Asia Pacific
14615 Lone Oak Road Route de la Longeraie 7 11th Floor Hong Kong New World Tower
Eden Prairie, MN 55344 1110 Morges 300 Huaihai Zhong Road
USA Switzerland Shanghai 200021
Tel: 952-937-9800 Tel: +41 (0) 21 811 4600 China
Fax: 952-294-7722 Fax: +41 (0) 21 811 4601 Tel: 86-21-6387-9988
www.hydraulics.eaton.com Fax: 86-21-6335-3912

2007 Eaton Corporation


All Rights Reserved
Printed in USA
Document No. E-FIFI-MC002-E2
Supersedes E-FIFI-MC002-E1
December 2007

You might also like