Professional Documents
Culture Documents
Ctalogo Filtros PDF
Ctalogo Filtros PDF
Technical Catalog
MODEL PAGE MODEL PAGE
The systemic contamination Once the target has been There are four primary
control approach assures set, the next step is to sources for solid
the user of the hydraulic select and position filters contamination to enter
system a cost effective in the system so that the a hydraulic fluid.
approach to contamination target can be achieved in They are: contaminated new
control that allows the price a cost effective manner. oil, built-in contamination,
of the filters and elements After the machine is in ingressed contamination
to be quickly recovered by operation, the last and and internally-generated
the savings of improved ongoing step is to confirm contamination.
performance, increased that the target cleanliness
component life, increased oil level is being maintained.
life, increased uptime and
fewer repairs. This is most often
accomplished by sending
The goal of systemic a fluid sample to a particle
contamination control is counting laboratory that
always the same: to clean gives cleanliness code data
the fluid to the point that to established standards. If
contamination is not a factor the target is being met, the
in the failure (catastrophic, system only needs to have
intermittent, or degradation) Eaton Fluid Analysis Service PN 894276
For a hydraulic or oil filters maintained and the
of any component in the fluid retested periodically. If
lubricated machine, the
system during the desired the cleanliness target is not
development of a target
useful life of that system. being achieved, corrective
cleanliness level and the
plan to achieve it is as much The first step towards this actions need to be taken.
a part of system design as goal is the setting of a target Sometimes a change in
the selection of the pump, cleanliness level that takes maintenance practices is
valves, actuators or bearings. into account the specific needed, but at other times a
needs of the system. shift to a finer grade of filter
elements or additional filter
Vickers Systemic Sources of Contamination housings may be needed.
Approach to Eaton doc. 561, page 8
Contamination Control
Generated Ingressed from cylinder rod
Set a target Cleanliness by cylinder
Level
Select filters and filter
placements to achieve A B
target
Generated by valve
Sample fluid and confirm P T
achievement
Pressure
line filter
Return
line
Ingressed from Generated filter
air breather Ingressed
by pump through
M reservoir M
openings Ingressed
from
Built-in debris new oil
Contaminated New Oil be metal, silica and fibers. Ingressed Contamination Generated Contamination
Although hydraulic and With fluids from reputable Contamination from the The most dangerous
lubrication fluids are refined suppliers, sampling has immediate surroundings can contamination to a system is
and blended under relatively shown typical Cleanliness be ingressed into the fluid the contamination generated
clean conditions, the fluid Levels of 17/16/14 or dirtier. power or lubrication system. by the system itself. These
travels through many hoses Using a portable transfer cart On large installations, such as particles are work
and pipes before it is stored fitted with a high efficiency those within steelworks or hardened to a greater
in drums or in a bulk tank at filter, contamination should automotive plants, it is hardness than the surface
the users facility. At this be removed from new fluids relatively easy to know the from which they came, and
point, the fluid is no longer before the contamination environmental conditions, are very aggressive in
clean as the fluid lines it has enters and damages the though they vary considerably. causing further wear in the
traveled through have components in the system. For example, a coke oven system. In a system running
contributed metal and rubber system operates in conditions on properly cleaned fluid very
particles, and the drums Built-in Contamination very different from a similar few particles are generated,
have added flakes of metal New machinery always system in a cold mill. For although all components
or scale. Storage tanks are a contains a certain amount of mobile equipment, there is a (especially pumps) create a
real problem because water built-in contamination. Care very wide variation in small amount of particles
condenses in them causing in system assembly and in environmental conditions by during routine operation. In a
rust particles. Contamination new component flushing application, location and even system where these particles
from the atmosphere can reduces this but never by weather conditions (i.e. are not quickly captured the
eliminates it. Typical built-in high winds). elevated contamination levels
The key is to severely limit will cause the number of
the access that environmental additional generated particles
contamination has to enter to increase at a highly
the hydraulic or lubrication accelerated rate! The best
system. There are four major way to prevent
ways dirt can enter a system: contamination generation
reservoir vent ports (breathers), within a system is to start
power unit or system access with a clean (fully flushed)
plates, components left open system and keep the system
during maintenance and fluid clean.
cylinder seals.
also find its way into the Eaton H20 Gate Reservoir Breather BR110
tank unless satisfactory air
breathers are fitted. contaminants are burrs,
If the fluid is stored under chips, flash, dirt, dust, fiber,
reasonable conditions, the sand, moisture, pipe sealant,
principal contaminants on weld splatter, paint and
delivery to the machine will flushing solution.
Filter Element Initial Beta ratios and dirt capacity. Eaton Media Construction
Efficiency The most important
The international standard for information needed by a
rating the efficiency of a designer or user of a
hydraulic or lubrication filter hydraulic system is the
is the Multipass Filter system cleanliness they can
Performance Beta Test (ISO expect when that filter and
16889). The results of this media are properly installed
test are reported as a ratio of in the system.
number of particles greater Each grade of Eaton high
than a designated size efficiency filter media
upstream of the test filter construction is thoroughly
compared with the number multipass tested and then
of same size particles rated with the system
downstream of the test filter. cleanliness level expected to
These results are then be achieved with the use of
expressed as a Beta ratio. that product. The
Most Eaton filters are assumptions behind these may fail to answer the and gives the filter medium
rated at Beta x(c)=1000. See cleanliness ratings are: 1) the question of how an aged the support it needs to keep
individual filter Features and filter sees full system flow, element will perform during from failing due to fatigue.
Benefits for more detail. 2) the filter is the primary the latter part of its service The downstream wire mesh
filter in the system, and 3) life. also serves as a last chance
BETA RATIOS AND air breathers along with protection in case of
CORRESPONDING EFFICIENCIES The best way to deal with
recognized maintenance unexpectedly severe stress
Beta Ratios Efficiency this issue is to look at the
practices will limit dirt that causes element media
construction and feel the
1 0% ingression from the rupture.
element pleats. Are the
2 50.00% atmosphere.
pleats well supported? Do
5 80.00% A major problem in correlating they flex under hand Filter Condition Indicators
10 90.00% multipass test claims to real pressure? Any element that After the filters are placed
20 95.00% world fluid cleanliness levels fails these simple tests will within the system, the next
75 98.00% is that real systems operation fail to maintain efficiency and consideration is how the
100 99.00%
greatly stresses the element. integrity, and will not user is going to know when
In active systems, flow rate maintain the targeted to change the element. The
200 99.50% changes (often several times cleanliness level. answer recommended in
1000 99.90% a minute), pressure pulses DIN 24550 standard is to
5000 99.98% Additionally, look at the pack
(hundreds a minute), have all filters fitted with a
construction. Steel wire
Beta ratios and dirt capacity are only decompression shock differential pressure indicator
mesh is very important in
a guide to system cleanliness needs waves, cold starts and other that gives an easy-to-read
ref. Eaton doc. 561, page 19 element construction. Wire
variables all work to degrade indication that the element
keeps the pleats from flexing
a filters performance. In needs to be changed. Eaton
Multipass testing has greatly multipass testing the element
aided engineers in the is subject to one gradual rise LIMITS ON CORRELATION BETWEEN BETA AND SYSTEM
development of better and in differential pressure as the CLEANLINESS AND DIRT CAPACITY AND SERVICE LIFE
more efficient filter element loads! Laboratory Procedure Real World
elements, and it has helped Flow fatigue test protocol Pressure Rise One gradual rise Thousands of changes
the design engineer who (ISO 3724) leaves many Fatigue Cycles One Millions
needed to specify a filter important questions
elements performance. But, Element Aging Minutes Months
unanswered. Again the Element Life One hour 800+ hours
theres little correlation element is tested in laboratory
between multipass Contaminant AC fine test dust Debris, water, gas
conditions that cannot
efficiencies and system duplicate the interaction of Challenge Rate Constant Always changing
cleanliness needs. In the the many forces working to Fluid Used MIL 5606 Wide variety
final performance analysis, stress and degrade the Temperature 100F (38C) -20F to 200F (-7 to 93C)
the goal is properly cleaned element. This laboratory test Flow Steady Thousands of changes
fluid and not just very high
indicators are designed to In poorly supported elements, changes in flow and pressure drop cause the
indicate at a pressure drop sides of element corrugations to flex and the root to stretch, giving rise to fatigue
20% below the bypass stresses. Dirt capacity is also lost as areas of the medium have no flow.
setting which equates to Eaton doc. 561, page 21
95% of the elements
service life. This indication
before bypass feature was No flow Flow directions
incorporated to allow safe
operation of the machine Deflection under Filter medium
until the next shift change or high flow
convenient maintenance
opportunity.
Target Cleanlines that maintenance of the Housing for longer element life.
Using the Vickers Target system will be consistent The selected housing should Some systems require
Cleanliness Worksheet with current technology. be rated within the required filtration with no bypass,
(#578), it is easy to If in operation the system is flow and pressures of the such as servo applications.
determine the target ISO running dirtier than expected, application. Vickers H-Pak media is
Cleanliness Level for a corrective actions should be Important: If the system recommended for non-
system. This target is based initiated. Suggested corrective fluids specific gravity (SG) is bypass systems.
on the applications actions are: greater than 0.9 (for
components and system Check the indicator to example, water glycol), the Indicator
dynamics. see if the filters are on housing pressure drop (P) To meet ANSI Standard
by-pass. should be corrected for 12.2.5, filter assemblies
Placement and Media actual application. should have a device to
Check the sources of
Use the chart below to help ingression and correct indicate when the filter
select the appropriate filter problems. Specific Gravity requires servicing. Per ANSI
placement and grade of Corrections for Pressure Standard 12.2.6, the
media to acheive the target Check that the filters are Drops indicator should trip at
cleanliness level. For more positioned properly to see approximately 80% of the
maximum fluid flow. The filter housing flow
detail, consult the Eaton curves in this catalog can be bypass pressure setting. If
Guide to Systemic Consider using a finer adjusted using the following using a non-bypass housing,
Contaminaton Control, Pak grade equation: an indicator selling of
your Vickers representative, approximately 100 psid is
Add additional filters to Adjusted PHousing =
or the ANSI System recommended. Differential
the system. PCurve x Actual SG 0.9
Standards for Stationary pressure indicators are rated
Industrial Machinery. 6,000 psi working, 3,500 psi
Note: All systems need a Bypass Valve fatigue.
Filter Placement sealed reservoir with vent Bypass valve selection is
The chart below helps port filtration. based upon system
engineers select the grade requirements. According to
of Vickers media and the CAUTION ANSI Standard 12.2.6, filter
filter placement(s) that will assemblies whose elements
Before servicing the
acheive the required target cannot withstand full system
element, the bleed
cleanliness. It assumes the differential pressure without
plug in filter housing
system will experience damage should be equipped
must be loosened to relieve
average ingression and with bypass valves.
pressure. This will minimize
Generally, a higher bypass
fluid overflow.
pressure setting will allow
Full flow pressure Full flow pressure Pressure line/ Pressure line plus Recirculating loop at Recirculating loop at
line or return line line or return line recirculating loop at return line plus 20% of system volume 10% of system volume
20% of system volume recirculating loop per minute per minute
per minute
14/12/10 - 03 03 03 - -
15/13/11 - 03 03 05 - -
16/14/12 03 05 05 05 or 10 03 03
17/15/13 03 05 05 05 or 10 03 03
18/16/14 05 10 05 or 10 10 05 03
16/14/10 05 or 10 10 10 10 05 or 10 05
Comprehensive Testing Viscosity (ASTM D445): and degrades equipment if any, are needed. The lab
We use this test to determine performance. is also capable of testing to
The Eaton Fluid Analysis the viscosity of your oil. the new ISO 4406(1999)
Service is certified to ISO Drawdown Particle
Without proper hydraulic fluid Isolation: Using this test, standard (4, 6,14).
12025 and offers a full range viscosity, your equipment will
of tests specifically designed we determine the insoluble Spectrometric Analysis
suffer. Incorrect viscosity contaminates in hydraulic (ASTM D 5185): This shows
for the analysis of hydraulic leads to fluid breakdown,
and lubrication system fluid. fluids, both insoluble us the concentration of oil-
inefficient equipment particles and gel-like matter, soluble elements and
Our laboratory equipment operation, premature system
and test procedures provide organics and inorganics. indicates the additives and
failure and damage to other Used in conjunction with trace metal content in the
an exact analysis of your components.
hydraulic or oil lubricated photomicrography, the fluids. We use this technique
system, and our drawdown drawdown patch helps us to evaluate the condition
particle isolation procedure identify the source and type of the additives in a fluid
ensures accurate results. of fluid contaminants. rather than its particulate
Automatic Particle Count contamination. Used in
Our testing procedures (ISO 11500): We use a high- conjunction with automatic
can include: intensity laser light source and particle counting, it helps us
a photo sensor to count the accurately assess the
Photomicrography: We cleanliness level of the fluid.
scan and photograph a filter number and size of particles
patch using an optical in the fluid sample and then Energy Dispersive X-ray
microscope to find particle define contaminants Fluorescence (ASTM E
size and type. The scanning according to size distribution 1508): We perform Energy
Water (ASTM E203): We and quantities. Automatic Dispersive X-ray Fluorescence
process verifies the determine the water content
automatic particle count to particle counting is quick, (XRF) analysis on samples
in hydraulic fluid, which helps repeatable and accurate. It with extremely high
identify samples needing us predict quality and
special preparation. This provides reliable information concentrations of particulate
performance characteristics we can use to check against contamination. By isolating
provides confirmation of for the fluid and system
automatic counter results, ISO Standard 4406, which chemical elements, we
components. Excess water defines the relationship pinpoint contaminant types so
and helps us see what reduces the viscosity of
contaminants are in the fluid. between particle counts and we can establish their origins,
hydraulic fluid, which hydraulic fluid cleanliness. and so you can take corrective
increases the likelihood of This lets us determine exactly action.
adverse chemical reactions what corrective actions,
2. Trend Information: We
evaluate data from your VISCOSITY
previous two samples On-target Re-sample
along with the results of Marginal Immediate action
your current sample. This
provides a trend analysis
of critical measurements, TEST 1 TEST 2 TEST 3
and shows changes in the Time Present Previous #1 Previous #2
fluid over time. Viscosity 45.0 (210) 45.5 (212) 45.8 (213)
@ 100F cSt (SUS)
pH (ASTM E 70)
represents the strength of Water 0.03% 0.03% 0.03%
% Weight
Vacuum Pump PN 894279 acidity in hydraulic fluid,
and is usually measured pH 9.4 9.5 9.6
Note: pH is for water containing fluids only.
for water-containing
hydraulic fluids TAN mg KOH/gm 2.1 2.0 2.1
Note: TAN is for synthetic fluids only.
(water/glycols, invert
emulsions). Typical values
are 8.510.5. Particle Count Summary
Total Acid Number, or TEST 1 TEST 2 TEST 3
Time Present Previous #1 Previous #2
TAN (ASTM D 974), is the
amount of acid and acid- >2 65,120 4,100 418
acting material constituents >5 12,220 1,250 88
in hydraulic fluid. An >10 5,800 700 39
increase in TAN indicates >15 900 250 22
oxidation or acid >25 125 60 4
contamination. Some >50 12.0 5.0 1.0
hydraulic fluids exhibit
higher acid numbers than Cleanliness 23/21/17 19/17/15 16/14/12
Code
others. Typical values are
0.13.0.
KIT FEATURES
Photo Energy
Automatic Microscopy Dispersive Spectrographic
Particle Water Viscosity Drawdown XRF ASTM Analysis
Kit Count ASTM TAN/PH ASTM Particle E1508 ASTM
Part # ISO 11500 E203 (if applicable) D445 Isolation (if applicable) D5185
894276
894277
Each kit includes:
Super clean sample bottle
Packaging for sending sample
Numbered test sample data form
Fluid analysis service
Also available is PN 894279, Vacuum Pump for extracting oil sample, and PN 932339, Ultra Clean Bottle.
Items not in bold are non-standard and may have a longer lead time
12 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Cleanliness Code Graph
Fluid Analysis Range Code
300,000
25 200,000
100,000 150,000
24 100.000
80,000
3. Cleanliness Code Graph: 23 50,000
This graph uses the ISO 40,000 40,000
22 30,000
4406 standard for 20,000 20,000
measuring and depicting 21 15,000
10,000 10,000
the amount and size of 20
5,000 5,000
particles per milliliter in 4,000
hydraulic fluid, shown in a 19 3,000
2,500 2,000
log-log2 graph that charts 18 1,500
the amount of particles 1,000 1,000
17
Out
to Waste
Sample Bottle Target-Pro 2 software for
Bottle Windows, included with the
analyzer, allows you to
download test results and
Quick Coupling Connector analyze cleanliness trends
over time.
Vacuum
Cap
TECHNICAL INFORMATION
Technology Automatic Optical Particle Analyzer Operation Max. system working pressure,
Laser Package Twin Laser and Twin Optical 400 bar; Min. working pressure, 2 bar
Diode Detectors Viscosity Range to 400 centistokes
LCD display (backlit) Operating Temperature +5 to +80C
Sensitivity >4, 6, 14, 21, 25, 38, 50, 68 Fluid Compatibility Mineral oil and petroleum based fluids
m(c), Micron range to revised (consult Eaton for other fluids)
ISO 4406 Standard
Typical Test Time Result in <2.5 mins. (normal test)
Accuracy/Repeatability Better than 3% typical
Power Internal rechargeable battery
Calibration Each unit is individually calibrated with (AC charger) or external 12/24 volt
ISO Medium Test Dust (MTD) to DC power supply
ISO 11171:1999 on equipment
Data Storage 600 tests
certified by I.F.T.S.
Computer Interface RS-232 (serial) communication port
Analysis Range ISO 8 to ISO 24 to ISO 4406
(NAS 1638-2 to 12) Hose Connections minimess fittings microbore hose, 1.5 m
waste fluid hose
Report/Print Format ISO and NAS codes, with individual
particle counts as a built-in option Dimensions Height 210mm; Depth 260mm;
Width 430mm; Weight 7.6 kg
Printer Fixed head thermal printer
(384 dots per line) 5002405 - Particle Counter
5002406 - Bottle Sampling
Target-Pro 2 Sample Volume 15 ml. (normal), 30 ml. (dynamic)
24 ml. (bottle sampler) 15 ml.
(continuous), 8ml. (short)
Note:
The TargetPro should only be operated on petroleum based
fluids, synthetic or biodegradable fluids. For phosphate
esters, Skydrol, crankcase fluids with high soot content,
or water glycol, please consult Eaton.
Hydraulic reservoirs breathe air in and out as the oil level rises and falls.
This circulating air contains particles and moisture that can cause
corrosion, increase equipment wear and reduce fluid performance. In
typical systems, the internal hydraulic fluid is warmer than the
external environment. This difference in temperatures causes
water vapor to form. Breathers protect your hydraulic
system by filtering out damaging moisture and particles.
More than 25% of the samples sent to the Eaton Fluid
Analysis Laboratory for analysis have significant water
contamination. In an operating system, the H20-gate
Vent Breather creates a moisture barrier when there
is a 5F (2C) difference between reservoir and
ambient temperature and when there is a 10%
per minute exchange of air volume above the
fluid. The Mobile-gate breather is smaller in
size but is also 1/4 the size and 1/2 the capacity
of the H20-gate. These temperature and air flow
conditions are present in most hydraulic systems
which employ a cylinder.
Part Numbers:
NPT Mobile-gate MBR110
Flange Mobile-gate MBR120
H20-gate BR110
Dirt-gate BR210
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 17
Breathers
105
(4.13)
184,2 12
(7.25) (.47)
12
(.47)
1.5 UN Straight Thread
2.2 2.2
Inches of water
bar (psi)
(.073)
bar (psi)
1.7 1.7
1.2 1.2
1.0 .0025 1.0 .0025
(.036) (.036)
0.7 0.7
0.2 0.2
0 10 20 30 40 50 60 70 80 90 0 10 20 30 40 50 60 70 80 90
Air Flow, SCFM Air Flow, SCFM
Mobile-gate Specifications
PART NUMBER FLOW DIMENSIONS (in)
USgpm L/min D1 D2 D3 D4 H1 H2 T1
MBR110 125 475 3.08 - - 2.33 0.63 NPT 3/4
MBR120 125 475 3.08 1.88 - 2.50 3.50 -
MBR120 FLANGE - - - - 0.25 2.81 - - -
D1 D1
H1 H1 D3
D4
H2
H2 T1
D2
18 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Breathers
Adapters
Installation Dimensions
General Data
Return line filters usually have spin-on type elements, Return line filters may also be equipped with fluid
cartridge elements in an in-line mounted housing, or sampling devices to monitor the fluid cleanliness
cartridge elements within a housing that is mounted level. Secondary ports may also be incorporated to
directly within the reservoir itself (sometimes referred add make-up fluid and ensure that the fluid is
to as an in-tank filter). transferred through a filter before entering the system.
Applications
Stroke boom delimbers
Drilling platforms
Die cast machines/
injection molding
Large machine tools
Items not in bold are non-standard and may have a longer lead time
20 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Return Line Flows to 280 L/min (75 USgpm)
Pressures to 50 bar (725 psi)
Filters
HV3R Series
Beta Ratio: x(c) = 1000 Rated flow: Length 1 160 L/min (42 USgpm)
to ISO 16889 Length 2 240 L/min (63 USgpm)
Length 4 280 L/min (74 USgpm)
Designed to comply with Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids
ANSI specifications and Optional seals available for phosphate esters.
ISO cleanliness standards Temp range: -30C to 121C (-22F to 250F)
Visual and electrical Pressure rating: Operating 50 bar (725 psi)
indicators with lamp Fatigue 50 bar (725 psi)
options for system design Material: Head Aluminum
flexibility Bowl Carbon Steel
Fully serviceable without Collar Carbon Steel
tools Dry weight: Length 1 2,3 kg (5.1 lbs)
Zero leak by-pass valve (Approximate) Length 2 2,5 kg (5.5 lbs)
Length 4 3,4 kg (7.5 lbs)
construction
Wide range of element
lengths for maximum
design flexibility
High efficiency
replacement elements in
standard configurations
(C-Pak) to meet Target
Cleanliness Levels HV3R * ** * ** * * * **
High collapse elements
available for non-bypass 1 2 3 4 5 6 7 8 9
applications
HV3R Series 1 Filter Series - HV3R QH - Electrical 1 bar (15 psi) UH - Electrical 4.9 bar (70 psi)
Filter and Element Hirschmann Hirschmann
Model Code 2 Element Collapse Rating
LN - Visual (30 psi)
No Connector 6 Seal Material
1 - 17 bar (250 psi) Low Collapse RB - Electrical 2 bar (30 psi) B - Buna-N
Sample model code: 4 - 207 bar (3000 psi) High Brad Harrison V - Viton-A
Collapse RJ - Electrical 2 bar (30 psi) Viton is a registered trademark of E.I. DuPont
HV3R1SC4RLB2C05
3
Hirschmann w 24 volt
Port Options light 7 Assembly Length
BC - G 1-1/4 to ISO 228 RK - Electrical 2 bar (30 psi) mm (inch)
SC - 1.625 - 12UN SAE-20 str. Hirschmann w 115 volt 1 - 207 (8.15)
Thd. (1-1/4" tube) light 2 - 266 (10.47)
RL - Electrical 2 bar (30 psi) 4 - 447 (17.6)
4 Valve Options Hirschmann w 230 volt
1- Non-Bypass light 8 Element Construction
3- Bypass set at 1.7 bar (25 psi) RH - Electrical 2 bar (30 psi) C - 17 bar (250 psi) Low Collapse
4- Bypass set at 3 bar (43 psi) Hirschmann H - 207 bar (3000 psi) High
6- Bypass set at 6 bar (87 psi) AN - Visual (70 psi) Collapse
No Connector X - no element
5 Indicator Options UB - Electrical 4.9 bar (70 psi)
JN - No Indicator (plug), Brad Harrison 9 Fluid Cleanliness Rating
No Connector UJ - Electrical 4.9 bar (70 psi) Target fluid
QB - Electrical 1 bar (15 psi) Hirschmann w 24 volt Code cleanliness level
Brad Harrison light *03 16/14/12 or better
QJ - Electrical 1 bar (15 psi) UK - Electrical 4.9 bar (70 psi) *05 18/16/14 or better
Hirschmann w 24V light Hirschmann w 115 volt
light *10 20/18/15 or better
QK - Electrical 1 bar (15 psi)
Hirschmann w 115V light UL - Electrical 4.9 bar (70 psi) *20 22/19/16 or better
QL - Electrical 1 bar (15 psi) Hirshman w 230 volt light XX no element
Hirschmann w 230V light
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 21
Return Line Flows to 280 L/min (75 USgpm)
Pressures to 50 bar (725 psi)
Filters
HV3R Series
V3R * * * **
1 2 3 4 5
56
(2.2)
130
7.4 (5.12) Indicator Plug
(0.29)
Label
46.4
(1.83)
1 5/8-12UNF in. or G 1 1/4 port
SAE-20 port
2 PL'S
Refer to
Model Code
82.5
(3.25)
50.0 (1.97) 125
Clearance for (4.92)
Element Removal
Items not in bold are non-standard and may have a longer lead time
22 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Return Line Flows to 280 L/min (75 USgpm)
Pressures to 50 bar (725 psi)
Filters
Flow versus pressure drop:
HV3R Series 150 SUS (32 cSt) oil with specific gravity of <0.9
Flow Data
4,0 58
1,0
0,8 12 3,0
0,6 2,0 29
0,4 6
1,0
0,2
0
0 50 100 150 200 250 300 0 50 100 150 200
Flow Rate - L/min Flow Rate - L/min
Sample P Calculation : HV3R1SC4RLB2C05 - Filter assembly having '2' length filter element with micron rating
code '05' at 100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.7x 0.8/0.9 + 100 x 0.006 x 46/32 x 0.8/0.9
= 0.620 + 0.76
= 1.38 bar
Beta Ratio: x(c) = 1,000 Rated flow: Length 5 1,300 L/min (343 USgpm)
to ISO 16889 Length 8 1,700 L/min (450 USgpm)
Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
Designed to comply with Optional seals available for phosphate esters.
ANSI specifications and
Temp range: -30C to *121C (-22F to *250F)
ISO cleanliness standards
Pressure rating: Operating 25 bar (360 psi)
Easy to remove cap to Fatigue 25 bar (360 psi)
facilitate element change
Material: Head, Housing, Lid Aluminum
and minimize spillage
Dry weight: Length 5 17 kg (37 lbs)
Vent and drain ports to (Approximate) Length 8 23 kg (50 lbs)
facilitate maintenance and
Port Size: 4in SAE Code 61 Flange with Metric threads (M16 bolts provided)
system start-up
Delta P visual, electrical,
and electrical indicators
with lamp options for
system design flexibility
High efficiency
replacement elements in
standard configurations
(C-Pak)
HV6R 1 * * ** * * * **
1 2 3 4 5 6 7 8 9
HV6R Series 1 Filter Series - HV6R QK - Electrical 1 bar (15 psi) UH - Electrical 4.9 bar (70 psi)
Filter and Element Hirschmann w 115V light Hirschmann
Model Code 2 Element Collapse Rating
QL - Electrical 1 bar (15 psi)
Hirschmann w 230V light 6 Seal Material
1 - 10 bar (150 psi) QH - Electrical 1 bar (15 psi) B - Buna-N
Sample model code: Hirschmann V - Viton-A
3 Mounting Options
HV6R1MT4RLB8C05 RB - Electrical 2 bar (30 psi)
F - In-line Brad Harrison 7 Assembly Length
T - In-tank RJ - Electrical 2 bar (30 psi) mm (inch)
Hirschmann w 24 volt 5 - 606 (23.9)
4 Valve Options light 8 - 1045 (41.1)
1 - Non-Bypass RK - Electrical 2 bar (30 psi)
2 - Bypass set at 1.7 bar Hirschmann w 115 volt 8 Element Construction
(25 psi) cracking pressure light C - Standard Construction
4 - Bypass set at 3 bar (43 psi) RL - Electrical 2 bar (30 psi) L - Deep pleat Construction
cracking pressure Hirschmann w 230 volt X - no element
light
5 Indicator Options RH - Electrical 2 bar (30 psi) 9 Fluid Cleanliness Rating
AN - Visual 4.9 bar (70 psi) Hirschmann Target fluid
No Connector UB - Electrical 4.9 bar (70 psi) Code cleanliness level
KN - Visual 1 bar (15 psi) Brad Harrison 03 16/14/12 or better
No Connector UJ - Electrical 4.9 bar (70 psi)
05 18/16/14 or better
LN - Visual 2 bar (30 psi) Hirschmann w 24 volt
No Connector light 10 20/18/15 or better
JN - No Indicator (plug), UK - Electrical 4.9 bar (70 psi) 20 22/19/16 or better
No Connector Hirschmann w 115 volt XX no element
QB - Electrical 1 bar (15 psi) light
Brad Harrison UL - Electrical 4.9 bar (70 psi)
QJ - Electrical 1 bar (15 psi) Hirschmann w 230 volt
Hirschmann w 24V light light
Items not in bold are non-standard and may have a longer lead time
24 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Return Line Flows to 1,700 L/min (450 USgpm)
Pressures to 25 bar (360 psi)
Filters
HV6R Series
V041 1 * * * **
1 2 3 4 5 6
Clogging
Indicator G1/2 290
Port 130 Air Vent (11.42)
(5.12)
(Bolt Circle)
Clearance Required
for Element Changeout
Length 5
470
(18.50) 78 18
(3.06) Clearance Required (0.71)
for Element Changeout (4 places)
Length 8 260 770
915 (10.24) Venting (30.31)
(36.02) G 1/2
Length 5 352
606 G3/4 (13.86)
(23.86) Length 5 Fill Port INLET
606
Length 8 (23.86) 110
G1/2
1,045 Indicator (4.33)
(41.14) Length 8 Port
filling 1,045
INLET (41.14) Length 5
connection 232
G 3/4 (9.13) 254
(Tank (10.00)
78 Opening) Length 8
(3.06) 693
(27.28)
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 25
Return Line Flows to 1,700 L/min (450 USgpm)
Pressures to 25 bar (360 psi)
Filters
Flow versus pressure drop:
HV6R Series 150 SUS (32 cSt) oil with specific gravity of <0.9
Flow Data
5,0
4,0 58
0,10 1.5
3,0
2,0
0,05
1,0 15
0 0
0 300 600 900 1200 1500 0 300 600 900 1200 1500
Flow Rate - L/min Flow Rate - L/min
Sample P Calculation : HV6R1MT4RLB8C05 - Filter assembly having '8' length filter element with micron rating
code '05' at 200 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.) 0.8
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.01x 0.8/0.9 + 200 x 0.001 x 46/32 x 0.8/0.9
= 0.008 + 0.25
= 0.26 bar
Beta Ratio: x(c) = 1000 Rated flow: Length 1 1300 L/min (343 USgpm)
to ISO 16889 Length 2 1700 L/min (450 USgpm)
Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
Extremely large filtration Optional seals available for phosphate esters.
area and flow capacity
Temp range: -30C to +121C (-22F to +250F)
Designed for both in-tank Pressure rating: Operating 25 bar (360 psi)
and inline applications Fatigue 25 bar (360 psi)
Easy filter replacement Material: Head Aluminum
using screw-on lid Housing Aluminum
Manifolds Ductile Iron
Vent and drain ports are
standard Dry weight: Length 1 33,6 kg. (74 lbs)
(Approximate) Length 2 79,8 kg. (176 lbs)
Anodization is not Port size: 4 in SAE Code 61 Flange with metric threads (M16 bolts provided)
required for aluminum
alloy when using water For additional filtration HV6RD filters can be configured with multiple housings/elements
based fluids evenly mounted parallel to a single head. These configurations can be designed in evenly
Reusable contamination balanced series, for example: 2 x 2 would be 4 total elements with 2 on each side of the
basket prevents re-entry head. Contact Eaton to specify.
of retained contaminants
into the reservoir during
element replacement
HV6RD 1 * * * * * * ** *
Filters can be fitted with
clogging indicators to
1 2 3 4 5 6 7 8 9 10
monitor the contamination
level of the element
HV6RD duplex filters have 1 Filter Series - HV6RD MK - Electrical 1 bar (15 psi) 6 Seal Material
a ball-type selector valve Hirschmann w 115 volt
B - Buna-N
to provide continuous 2 light
Element Collapse Rating V - Viton-A
filtration and eliminate the ML - Electrical 1 bar (15 psi)
1 - 10 bar (150 psi) Low collapse Hirschmann w 230 volt
need to shut-down the 7 Assembly Length
system during element 3
light mm (inch)
Mounting Options MH - Electrical 1 bar (15 psi)
changeout F - Inline 1 - 606 (24)
Hirschmann 2 - 1045 (41)
Series HV6RD T - In-Tank RB - Electrical 2 bar (30 psi)
Filter Model Code Brad Harrison 8 Element Construction
4 Valve Options RJ - Electrical 2 bar (30 psi)
1- Non-Bypass C - Standard Construction
Hirschmann w 24 volt light
Sample model code: 2- Bypass set at 1.7 bar L - Deep Pleat Construction
RK - Electrical 2 bar (30 psi)
(25 psi) pressure X - no element
HV6RD1F2KNB1C05 Hirschmann w 115 volt
4- Bypass set at 3 bar light 9 Fluid Cleanliness Rating
(43 psi) cracking RL - Electrical 2 bar (30 psi)
Note: 6- Bypass set at 6 bar Hirschmann w 230 volt Target fluid
(87 psi) pressure light Code cleanliness level
Elements used in the HV6RD
are not dimensionally RH - Electrical 2 bar (30 psi) 03 16/14/12 or better
5 Indicator Options Hirschmann
equivalent to elements in the 05 18/16/14 or better
AN - Visual 4.9 bar (70 psi) UB - Electrical 4.9 bar (70 psi) 10 20/18/15 or better
HV6R series. An indicator is Brad Harrison
No Connector
supplied for each side. UJ - Electrical 4.9 bar (70 psi) 20 22/19/16 or better
KN - Visual 1 bar (15 psi)
No Connector Hirschmann w 24 volt light XX no element
LN - Visual 2 bar (30 psi) UK - Electrical 4.9 bar (70 psi)
No Connector Hirschmann w 115 volt 10 Flow Path
JN - No Indicator (plug), light A- Front inlet, front outlet
No Connector UL - Electrical 4.9 bar (70 psi) B- Front inlet, back outlet
MB - Electrical 1 bar (15 psi) Hirschmann w 230 volt C- Top inlet, front outlet
Brad Harrison light D- Top inlet, bottom outlet
MJ - Electrical 1 bar (15 psi) UH - Electrical 4.9 bar (70 psi) E- In-Tank mount
Hirshman w 24 volt light Hirschmann
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 27
Return Line Flows to 1,700 L/min (450 USgpm)
Pressures to 25 bar (360 psi)
Filters
HV6RD Series
V301 2 * * * *
1 2 3 4 5 6
V301 Element 1 Filter Element - V301 4 Element Length 6 Fluid Cleanliness Rating
model code mm (in) Target fluid
2 Element Collapse Rating 1 - 254 (10)
2 - 693 (27) Code cleanliness level
Sample model code: 2 - 17 bar (250 psi) Collapse
03 16/14/12 or better
V3012B1C10 3
5 Element Construction 05 18/16/14 or better
Seal Material
B - Buna-N C - C-pak (code 03, 05, 10, 20) 10 20/18/15 or better
V - Viton-A L - L-pak (code 03, 05, 10, 20) 20 22/19/16 or better
Housing Dimensions
Clearance Required
mm (inch) for Element Changeout
770 OUTLET OUTLET
In-tank (30.31)
352
Fill Port (13.86)
G 3/4
Indicator
Port
G 1/2
232
Length 1 (9.13)
606 (tank opening)
(23.86)
Length 1
Length 2 254
1045 (10.00)
(41.14)
Length 2
693
(27.28)
OUTLET OUTLET
18
(0.71) INLET
(8 places)
135
(5.31)
280
(11.02)
Vent Plug
G 1/2
290 510
(11.42) (20.08)
Bolt Circle
Items not in bold are non-standard and may have a longer lead time
28 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Return Line
Filters
Venting G 1/2
HV6RD Series
Housing
Dimensions
mm (inch)
In-Line
Filling
Connection
Clogging Indicator
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 29
Return Line Flows to 1,700 L/min (450 USgpm)
Pressures to 25 bar (360 psi)
Filters
Flow versus pressure drop:
HV6RD Series 150 SUS (32 cSt) oil with specific gravity of <0.9
Flow Data
5,0
4,0 58
0.50 8
3,0
2,0
0.25 4
1,0 15
0 0
0 500 1000 1500 2000 0 300 600 900 1200 1500
Flow Rate - L/min Flow Rate - L/min
Sample P Calculation : HV6RD1F2ANB1C05 - Filter assembly having '1' length filter element with micron rating code
'05' at 200 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.05 x 0.8/0.9 + 200 x 0.001 x 46/32 x 0.8/0.9
= 0.044 + 0.25
= 0.44 bar
Items not in bold are non-standard and may have a longer lead time
30 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Return Line Flows to 115 L/min (30 USgpm)
Pressures to 40 bar (600 psi)
Filters
OFR30 Series
OFR 30 * * * ** * 30
1 2 3 4 5 6 7 8
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 31
Return Line Flows to 115 L/min (30 USgpm)
Pressures to 40 bar (600 psi)
Filters
V602 1 * 2 C **
OFR30 Series 1 2 3 4 5 6
V602 Element 1 Filter Element -V602 4 Element Length 6 Fluid Cleanliness Ratings
Model Codes mm (inch) Target fluid
(Meets HF3 Specifications) 2 Element Collapse Rating 2 - 203 (8) (HF3 length) Code cleanliness level
1 - 10 bar (150 psi) Low 03 16/14/12
Sample model code: 5 Element Construction
Collapse 05 18/16/14
V6021B2C03 C - C-Pak (code 03, 05, 10, 20) 10 20/18/15
3 Seals
20 22/19/16
B - Buna-N
V - Viton-A
Housing Dimensions
Memory 52,3 (2.06) 3 / -16
UNC-2B
Mechanical Indicator 8
reset knob 26,2 (1.03) 0.64 min. full thread
mm (inch) 2-places
Visual indicator
13,2
(0.52)
269,7
133,4 (5.25) (10.62)
218,9 OFR-15
66,5 (8.62) 362,0
(2.62) Inlet port OFR-15 (14.25)
311,2 OFR30
180,8
(7.12) (12.25)
26,2 OFR15 OFR30
(1.03)
131,8 273,1
Outlet port (5.19) (10.75)
OFR30
66,5
(2.62)
Drain plug
87,4
1/2 NPTF thd. (3.44)
Connections
1.312-12 UN SAE 99,3
1" G1 British (3.91)
pipe thread or
1" SAE 4-bolt flg.
Torque head bolts to 267,5
25-30 ft.lbs (33-41 Nm) (10.53)
177,8 OFR-15
(7.00) 53,8 (2.12)
min. lead extension 359,7
(14.16)
OFR-30
Electrical Indicator Green
Switch Circuit
Blue C NC
NO
Red
Black
Items not in bold are non-standard and may have a longer lead time
32 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Return Line Flows to 115 L/min (30 USgpm)
Pressures to 40 bar (600 psi)
Filters
Flow versus pressure drop:
OFR 30 Series 150 SUS (32 cSt) oil with specific gravity of < 0.9
Flow Data
OFR30 C-Pak
1,7 25
C03
1,4 20
1,0 05 15
0,7 10
10
0,3 5
20
0
0 50 100 150 200 250
Flow Rate - L/min
2,5 36
0,3 2,0
1,5 22
0,2 OFR-30 3
1,0
0,1 0,5
0
0 25 50 75 100 125 150 50 100 150 200 250 300 350 400 450
Flow Rate - L/min Flow Rate - L/min
Sample P Calculation : OFR30SBC03M30 - Filter assembly having filter element with micron rating code '03' at 100
L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.22 x 0.8/0.9 + 0.5 x 46/32 x 0.8/0.9
= 0.193 + 0.632
= 0.83 bar
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 33
Return Line Flows to 450 L/min (120 USgpm)
Pressures to 27 bar (400 psi)
Filters
OFR 60/120
Series
Visual indicator is standard Rated flow: OFR60 225 L/min (60 USgpm)
OFR120 450 L/min (120 USgpm)
Electrical indicator also Fluid compatibility: Compatible with most petroleum oil, water
available glycol, oil-in-water and water-in-oil fluids.
Bypass valve is standard Temp range: -40C to +107C (-40F to +225F)
Replacement elements Pressure rating: Operating 27 bar (400 psi)
available in C-Pak Material: Head Die cast aluminum
Bowl Carbon steel
Dry weight: OFR60 6,8 kg (15 lbs)
(Approximate) OFR120 9,5 kg (21 lbs)
OFR *** * * * ** * ** 30
1 2 3 4 5 6 7 8 9
Items not in bold are non-standard and may have a longer lead time
34 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Return Line Flows to 450 L/min (120 USgpm)
Pressures to 27 bar (400 psi)
Filters
OFR 60/120 V405 1 * * C **
Series
1 2 3 4 5 6
V405 Element 1 Filter Element - V405 4 Element Length 6Fluid Cleanliness Rating
Model Code mm (inch) Target fluid
2 Element Collapse Rating 3 - 229 (9) (Use in OFR-60)* Code cleanliness level
(Meets HF4 Standard)
1 - 10 bar (150 psi) 6 - 457 (18) (Use in OFR-120) 03 16/14/12
Sample model code: 05 18/16/14
3 5 Element Construction
Seals 10 20/18/15
V4051B3C03 B - Buna-N C - C-Pak (code 03, 05, 10, 20) 20 22/19/16
V - Viton-A
*NOTE: Two 9 inch elements and a P-227567-01 reusable connector can also
be used in the OFR-120 housing. This arrangement meets HF4 specifications.
Housing Dimensions
320,5 550,9
Note: (12.62) (21.69)
Plastic plug, part number OFR60 OFR120
737365, is installed in the
filter element to close the
end of the element. When
servicing element, remove Drain plug
and retain plastic plug
737365. Install new element
with plastic plug on bottom. 117,9 Dia.
(4.64) 25,4 (1.00) Clearance
for element removal
Electrical Indicator
mm (inch) 1/2 NPTF thd. 90,9
(3.58)
119,1
177,8 (7.00) min. A port Conn. (4.69)
lead extension 2 places
Torque head bolts to
53,8 (2.12) 50 ft.lbs (67,79 Nm) dry
35 ft.lbs. (47,45 Nm)
lubricated
Electrical Indicator Green
Switch Circuit
Blue C NC
NO
Red
Black
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 35
Return Line Flows to 450 L/min (120 USgpm)
Pressures to 27 bar (400 psi)
Filters
Flow versus pressure drop:
OFR 60/120 150 SUS (32 cSt) oil with specific gravity of <0.9
Series
Flow Data
C03
Pressure drop-bar
0,6 8 0,6 8
0,4 05 6 0,4 05 6
0,3 10 4 0,3 4
10
0,1 2 0,1 2
20 20
0 0
0 50 100 150 50 100 150 200 250 300 350
Flow Rate - L/min Flow Rate - L/min
Pressure drop-bar
2,50
2,00 29
0,50 OFR-120 7
1,50
1,00 15
0,25 OFR-60
0,50
0 0
0 100 200 300 400 500 0 100 200 300 400
Flow Rate - L/min Flow Rate - L/min
Sample P Calculation : OFR060SBC03M2530 - Filter assembly having a filter element with micron rating code '03' at
200 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.2 x 0.8/0.9 + 0.7 x 46/32 x 0.8/0.9
= 0.170 + 0.885
= 1.07 bar
Items not in bold are non-standard and may have a longer lead time
36 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Return Line Flows to 400 L/min (106 USgpm)
Pressures to 25 bar (363 psi)
Filters
DLR DIN Series
Filters
Beta Ratio: x(c) = 1000 Rated flow: 160 160 L/min (42.2 USgpm)
250 250 L/min (66.0 USgpm)
to ISO 16889 400 400 L/min (105.7 USgpm)
Visual, electrical and Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
electrical indicators with Optional seals available for phosphate esters
light options for system Temp range: -30C to +100C (-22F to +212F)
design flexibility Pressure rating: Operating 25 bar (363 psi)
Fully serviceable without Material: Aluminum
tools
Dry weight: 160 4,3 kg (9.5 lbs)
Zero leak by-pass valve 250 4,9 kg (10.8 lbs)
construction 400 5,9 kg (13.0 lbs)
Wide range of element
lengths for maximum
design flexibility
High efficiency
replacement elements
in standard configurations
(C-Pak) to meet Target
Cleanliness Levels
DLR 1 *** ** * ** * * **
1 2 3 4 5 6 7 8 9
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 37
Return Line Flows to 400 L/min (106 USgpm)
Pressures to 25 bar (363 psi)
Filters
DLR DIN Series
Filters
VDP *** * C **
1 2 3 4 5
Element model code 1 Filter Element 3 Seal Material 5 Fluid Cleanliness Rating
VDP - DIN Standard Element B - Buna-N Target fluid
Sample model code: V - Viton-A Code cleanliness level
2 Nominal Size - Flow 03 16/14/12 or better
VDP160BC06 4
Assembly Length Element Construction 06 18/16/14 or better
160 - 160L/min (42.2USgpm) C - Standard Construction 10 20/18/15 or better
297mm(11.7") 25 22/19/16 or better
250 - 250L/min (66.0USgpm)
375mm(14.8")
400 - 400L/min
(105.7USgpm)
525mm(20.7")
DLR Housing
Dimensions in mm 43.5
Outlet
Inlet Port Size
See Chart
HI
Drain Plug
130 60 0.2
Items not in bold are non-standard and may have a longer lead time
F
38 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
F
Return Line Flows to 400 L/min (106 USgpm)
Pressures to 25 bar (363 psi)
Filters
DLR DIN Series
Filters
C -pak 160 0.013 (0.717) 0.009 (0.479) 0.005 (0.252) 0.004 (0.193)
250 0.005 (0.275) 0.003 (0.178) 0.002 (0.111) 0.001 (0.091)
400 0.003 (0.178) 0.002 (0.111) 0.001 (0.073) 0.001 (0.055)
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.
0.40 6.0
0.30 4.5
0.20 3.0
0.10 1.5
0.00 0.0
0 50 100 150 200 250 300 350 400
Flow Rate - L/min
Sample P Calculation : DLR1160BE6ANBC03 - Filter assembly having '160' size filter element with micron rating
code '03' at 100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.8x 0.8/0.9 + 100 x 0.013 x 46/32 x 0.8/0.9
= 0.700 + 1.65
= 2.35 bar
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 39
Return Line Flows to 400 L/min (105 USgpm)
Pressures to 25 bar (360 psi)
Filters
LND Duplex
Beta Ratio: x(c) = 1000 Rated flow: Length 1 160 L/min (42 USgpm)
to ISO 16889 Length 2 250 L/min (66 USgpm)
Length 4 400 L/min (105 USgpm)
Lightweight duplex filter Fluid compatibility: Compatible with all petroleum oils and synthetic fluids rated for use with
constructed of aluminum Fluoro-Rubber or Ethylene Propylene seals.
Aluminum alloy is water Temp range: -30C to + 121C (-22F to 250F)
tolerant - anodization is Pressure rating: Operating 25 bar (360 psi)
not required for high Fatigue 25 bar (360 psi)
water based fluids Material: Aluminum
(HWBF)
Dry weight: Length 1 10,3 kg (22.7 lbs)
The screw-in bowl allows (Approximate) Length 2 11,6 kg (25.6 lbs)
the filter element to be Length 4 13,0 kg (28.7 lbs)
easily removed for
replacement or cleaning
The standard model is
supplied with vent and
drain plugs and also a
connection for differential
clogging indicator
LND 1 SD * ** * * * **
1 2 3 4 5 6 7 8 9
LND Series 1 Filter Series - LND RJ - Electrical 2 bar (30 psi) 7 Assembly Length
Filter and Element Hirschmann w 24 volt
mm (inch)
Model Code 2 light
Element Collapse Rating 1 - 297 (11.7")
RK - Electrical 2 bar (30 psi)
1 - 250 psi Low Collapse 2 - 375 (14.8")
Hirschmann w 115 volt
Sample model code: 4 - 525 (20.7)
3
light
Port Options RL - Electrical 2 bar (30 psi)
LND1SD7ANV2C05 8 Element Construction
SD - 1.875 - 12 UN SAE - 24 Hirschmann w 230 volt
Straight thread light C - Standard Construction
UB - Electrical 4.9 bar (70 psi) X - no element
4 Valve Options Brad Harrison 9
1 - Non-Bypass UH - Electrical 4.9 bar (70 psi) Fluid Cleanliness Rating
4 - Bypass set at 2.9 bar Hirschmann Target fluid
(43 psi) cracking pressure UJ - Electrical 4.9 bar (70 psi) Code cleanliness level
7 - Bypass set at 7 bar (102 Hirschmann w 24 volt 03 16/14/12 or better
psi) cracking pressure light 05 18/16/14 or better
UK - Electrical 4.9 bar (70 psi) 10 20/18/15 or better
5Indicator Options Hirschmann w 115 volt 20 22/19/16 or better
AN - Visual 4.9 bar (70 psi) light
UL - Electrical 4.9 bar (70 psi) XX no element
No Connector
JN - No Indicator (plug), Hirschmann w 230 volt
No Connector light
LN - Visual 2 bar (30 psi)
6 Seal Material
No Connector
RB - Electrical 2 bar (30 psi) B - Buna-N
Brad Harrison V - Viton-A
RH - Electrical 2 bar (30 psi)
Hirshmann
Items not in bold are non-standard and may have a longer lead time
40 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Return Line Flows to 400 L/min (105 USgpm)
Pressures to 25 bar (360 psi)
Filters
LND Duplex VDP *** * C **
1 2 3 4 5
Element model code 1Filter Element 3 Seal Material 5 Fluid Cleanliness Rating
VDP - DIN Standard Element B - Buna-N Target fluid
Sample model code: V - Viton-A Code cleanliness level
2 Nominal Size - Flow 03 16/14/12 or better
VDP160BC06 4
(2 elements required) Assembly Length Element Construction 06 18/16/14 or better
160 - 160L/min (42.2USgpm) C - Standard Construction 10 20/18/15 or better
297mm(11.7") 25 22/19/16 or better
250 - 250L/min (66.0USgpm)
375mm(14.8")
400 - 400L/min
(105.7USgpm)
Housing Dimensions 525mm(20.7")
mm (inch)
vent "clean side" SW 5
(connection G 3.175)
210
(8.27) mounting holes
9.525 - 24 UNF
(19.05 deep - 4 places)
62
(2.44)
vent "contamination side" SW 5
(connection G .125)
282
(11.10) G 1/2" Indicator Port
Inlet Outlet
Length 1
297
(11.69)
Length 2
375
(14.76)
Length 4
525
(20.67)
Drain Plug
100 G 12.7
(3.94)
85 130
(3.34) (5.12)
Clearance required
for element removal
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 41
Return Line Flows to 400 L/min (105 USgpm)
Pressures to 25 bar (360 psi)
Filters
Flow versus pressure drop:
LND Duplex 150 SUS (32 cSt) oil with specific gravity of <0.9
Flow Data
22.5
Pressure Drop - psi
1,5
1,0 15.0
0,5 7.5
0 0
0 100 200 300
Flow Rate - L/min
Sample P Calculation : LND1SD1ANV2C05 - Filter assembly having '2' length filter element with micron rating code
'05' at 100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.2 x 0.8/0.9 + 100 x 0.003 x 46/32 x 0.8/0.9
= 0.170 + 0.38
= 0.55 bar
Items not in bold are non-standard and may have a longer lead time
42 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
Notes
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 43
In-tank Filters
General Data
In-tank filters are a special type of low pressure return The filter housing may be equipped with diffusers
line filters. In-tank filters are mounted directly to the to ensure that the returning oil energy is gradually
reservoir tank top and have an accessible head that is dissipated within the reservoir fluid to minimize
located outside of the reservoir while the body of the the potential for aerating or foaming of the oil. In
housing is located inside the reservoir. The exposed addition, the diffuser helps direct the fluid outward
cover allows the element to be easily replaced as against the walls of the reservoir to aid in the heat
needed. transfer capability of the reservoir.
Applications
Forestry harvesting
equipment such as
delimbers and feller
bunchers
Injection molding or blow
molding equipment
Offshore drilling platform
power units
Machine tools
Die cast machines
Items not in bold are non-standard and may have a longer lead time
44 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
In-tank Filters Flows to 50 L/min (13.2 USgpm)
Pressures to 7 bar (100 psi)
OFMT020 Series
OFMT 020 Series 1 Filter Series - OFMT020 5Port Options 7 Element Collapse Rating
Filter and Element G1 - G 3/8 to ISO 228 H - 10 bar (150 psi)
Model Code 2 Assembly Length G2 - G 1/2 to ISO 228
G4 - 3/8" NPT 8 Valve Options
mm (inch)
Sample model code: 1 - 102 (4.0) G5 - 1/2" NPT B - Bypass set at 1.7 bar
2 - 165 (6.5) G7 - 0.5625 - 18 UN SAE-6 (25 psi) cracking pressure
OFMT0201SAG7A06HBT 3 - 210 (8.3) Straight thread
G8 - 0.75 - 16 UN SAE-8 9 Indicator Options
3 Breather Options Straight thread T - No Indicator (plug),
S - No breather 6
No Connector
C - 10 m breather Fluid Cleanliness Rating
M - 40 m breather Target fluid
Code cleanliness level
4 Seal Material A03 16/14/12 or better
A - Buna-N A06 18/16/14 or better
V - Viton-A A10 20/18/15 or better
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 45
In-tank Filters Flows to 50 L/min (13.2 USgpm)
Pressures to 7 bar (100 psi)
OFMT020 Series
FM020 * A** H *
1 2 3 4 5
Element model code 1 Filter Element - FM 020 3 Fluid Cleanliness Rating 4 Element Collapse Rating
Target fluid H - 10 bar (150 psi)
Sample model code: 2 Asembly Length Code cleanliness level
A03 16/15/12 or better 5 Seal Material
FM0202A06HA mm (inch)
1 - 102 (4.0) A06 18/16/14 or better A - Buna-N
2 - 165 (6.5) A10 19/17/14 or better V - Viton-A
3 - 210 (8.3) Note: Element comes with
bypass set at 25 psi cracking
pressure
Housing Dimensions
mm (inch)
60 (2.36 48 (1.89)
R 11,5 (0.45)
84 88
(3.31) (3.46)
46 (1.81) M10
R 5,5 (0.22)
61 (2.40)
62
(2.44)
21 (0.83)
84/88 (3.31/3.46)
Anti-splash
H
24 (0.94)
27 (1.06)
51 (2.01)
Items not in bold are non-standard and may have a longer lead time
46 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
In-tank Filters Flows to 50 L/min (13.2 USgpm)
Pressures to 7 bar (100 psi)
OFMT020 Series
Flow Data
0,75 10.9
06
00,50 7.2
10
0,25 3.6
0,00 0.0
0 15 30 45 60 75 90
Flow rate - L/min
Housing/Bypass Valve Flow Data
Housing Bypass Valve
Based on mineral oil with density of 0,86 kg/dm
P varies proportionally to density.
Flow rate - USgpm Flow rate - USgpm
0 6.6 13.2 19.8 26.4 33.0 0 4 8 12 16 20 24
0,4 6.0 3 45
1/2
0,3 4.5
2 30
Pressure drop - bar
Pressure drop - bar
0,2 3.0
1 15
0,1 1.5
0,0 0 0.0 0 0
0 25 50 75 100 125 0 15 30 45 60 75 90
Flow rate - L/min Flow rate - L/min
Sample P Calculation : OFMT0201SAG7A06HBT - Filter assembly having filter element with micron rating code '06'
at 25 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.02 x 0.8/0.9 + 0.5 x 46/32 x 0.8/0.9
= 0.017 + 0.632
= 0.65 bar
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 47
In-tank Filters Flows to 70 L/min (18.5 USgpm)
Pressures to 7 bar (100 psi)
OFMT100 Series
4 6
Fluid Cleanliness Rating
Seal Material
A - Buna-N Target fluid
V - Viton-A Code cleanliness level
A03 16/14/12 or better
A06 18/16/14 or better
A10 20/18/15 or better
Items not in bold are non-standard and may have a longer lead time
48 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
In-tank Filters Flows to 70 L/min (18.5 USgpm)
Pressures to 7 bar (100 psi))
OFMT100 Series
FM100 * A** H *
1 2 3 4 5
Element model code 1 Filter Element - FM 100 3 Fluid Cleanliness Rating 4 Element Collapse Rating
Target fluid H - 10 bar (150 psi)
2 Assembly Length Code cleanliness level
A03 16/15/12 or better 5 Seal Material
Sample model code: mm (inch)
1 - 102 (4.0) A06 18/16/14 or better A - Buna-N
FM1002A06HA 2 - 145 (5.7) V - Viton-A
A10 19/17/14 or better
3 - 225 (8.9) Note: Element comes with
bypass set at 25 psi cracking
pressure
Housing Dimensions
mm (inch)
9 (0.35) A
54
(2.13)
116
(4.57)
R 11,5 (0.45)
71 (2.80)
76 (2.99)
108 (4.25)
Holes required on tank
68 (2.68)
95 26
(3.74) (1.02) 87/90 M8
(3.43/3.54)
32 (1.26)
40 (1.57)
20 (0.79) 116
only for air (4.57)
breather
48 C indicator connection
(1.89) 59 (2.32)
H 86 (3.39)
111 (4.37)
24 (0.94) 38 (1.50)
80 (3.15)
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 49
In-tank Filters Flows to 70 L/min (18.5 USgpm)
Pressures to 7 bar (100 psi))
OFMT100 Series
Flow Data
03 10
06
0,75 10.9
0,50 7.2
0,25 3.6
0,00 0.0
0 25 50 75 100 125 150
Flow rate - L/min
0,3 4.5 3 45
0,2 3.0 2 30
1
0,1 1.5 1 15
1-1/4
0,0 0.0 0 0
0 50 100 150 200 250 0 25 50 75 100 125 150
Flow Rate - L/min Flow Rate - L/min
Sample P Calculation : OFMT1001SAG7A06HBT - Filter assembly having filter element with micron rating code '06'
at 50 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.015 x 0.8/0.9 + 0.55 x 46/32 x 0.8/0.9
= 0.013 + 0.695
= 0.71 bar
50 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
In-tank Filters Flows to 105 L/min (27.7 USgpm)
Pressures to 10 bar (150 psi)
OFRT100 Series
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 51
In-tank Filters Flows to 105 L/min (27.7 USgpm)
Pressures to 10 bar (150 psi)
OFRT100 Series
FT100 * A** *
1 2 3 4
Element model code 1 Filter Element - FT 100 3 Fluid Cleanliness Rating 4 Seal Material
Target fluid A - Buna-N
Sample model code: 2 Element Length Code cleanliness level V - Viton-A
mm (inch) A06 18/16/14 or better
FT1002A06A
1- 128 (5.0) A10 20/18/15 or better
2- 172 (6.8)
3- 222 (8.7)
4- 322 (12.7)
Housing Dimensions
mm (inch)
71 (2.80)
Inlet connection A
With air
breather
86 G indicator 59 (2.32)
(3.39) connection
111 (4.37)
77 (3.03) filter
element
length
H
80
(3.15)
72 (2.83)
80 (3.15)
With Without
Diffuser Diffuser
Items not in bold are non-standard and may have a longer lead time
52 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
In-tank Filters Flows to 105 L/min (27.7 USgpm)
Pressures to 10 bar (150 psi)
OFRT100 Series
Flow Data
Sample P Calculation : OFRT1001COSAG7A06T - Filter assembly having filter element with micron rating code '06'
at 25 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.01 x 0.8/0.9 + 0.3 x 46/32 x 0.8/0.9
= 0.008 + 0.38
= 0.49 bar
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 53
In-tank Filters Flows to 105 L/min (27.7 USgpm)
Pressures to 10 bar (150 psi)
OFRT250 Series
High efficiency filter Rated flow: Length 1 115 L/min (30.4 USgpm)
Length 2 160 L/min (42.3 USgpm)
elements with superior Length 3 205 L/min (54.2 USgpm)
dirt-holding capacity Length 4 360 L/min (95.1 USgpm)
designed for return lines Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water
and installed semi- and water-in-oil fluids, Optional seals available for phosphate esters.
immersed in a reservoir Temp range: -25C to +110C (-13F to +230F)
Excellent pressure drop Pressure rating: Operating 10 bar (150 psi)
characteristics Fatigue 10 bar (150 psi)
Indicators ordered Material: Head Die Cast Aluminum
separately Cover Aluminum
Dry weight: Length 1 3,9 kg. (8.60 lbs.)
Bowl length options for (Approximate) Length 2 4,1 kg. (9.04 lbs.)
design flexibility Length 3 4,6 kg. (10.14 lbs.)
Easy element changes Length 4 4,8 kg. (10.58 lbs.)
Bypass valve prevents
excessive pressure drop
and prevents element OFRT250 * C * S * ** A** T
collapse and release of
retained contaminants 1 2 3 4 5 6 7 8 9
back into hydraulic
system
1 Filter Series - OFRT 250 5
Breather Options F1 - 1-1/2" SAE Flange Code
Designed to comply with 61 with metric bolts
ISO standards S - No breather F2 - 1-1/2" and 1-1/4" in SAE
2 Assembly Length
6 Flange Code 61 with
mm (inch) Seal Material
metric bolts (dual)
OFRT 250 Series 1- 285 (11.2) A - Buna-N F3 - 1-1/2 in SAE Flange
Filter and Element 2- 335 (13.2) V - Viton-A Code 61 with UNC bolts
3- 405 (15.9) F4 - 1-1/2 in and 1-1/4 in SAE
Model Code 4- 610 (24.0) 7
Port Options Flange Code 61 with UNC
Length given does not include diffuser (G-threaded, F-flanged) bolts
Sample model code: G1 - G1-1/2 to ISO 228
3 Bypass Options
OFRT2501COSAG7A06T G2 - G - 1-1/2 and G 1-1/4 to 8 Fluid Cleanliness Rating
C - Bypass set at 1.7 bar ISO 228 (dual) Target fluid
(25 psi) cracking pressure G4 - 1-1/2" NPT Code cleanliness level
G5 - 1-1/2 " and 1-1/4"
4 Diffuser Options A06 18/16/14 or better
NPT (dual)
O - No diffuser G7 - 1.875 - 12 UN SAE -24 A10 20/18/15 or better
D - With diffuser Straight thread
G8 - 1.625 - 12 UN SAE - 20 9 Indicator Options
and 1.875 - 12 UN SAE - T - No Indicator (plug),
24 Straight thread (dual) No Connector
Items not in bold are non-standard and may have a longer lead time
54 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
In-tank Filters Flows to 105 L/min (27.7 USgpm)
Pressures to 10 bar (150 psi)
OFRT250 Series
FT250 * A** *
1 2 3 4
Element model code 1 Filter Element - FT 250 3 Fluid Cleanliness Rating 4 Seal Material
Target fluid A - Buna-N
Sample model code: 2 Element Length Code cleanliness level V - Viton-A
mm (inch) A06 18/16/14 or better
FT2502A06A
1- 175 (6.9) A10 19/17/14 or better
2- 225 (8.9)
3- 295 (11.6)
4- 500 (19.7)
Housing Dimensions
mm (inch)
Single inlet models
150 (5.91) 150 (5.91)
Port B
Port Port
A A 150
150
(5.91) (5.91)
175
(6.89)
11 (0.43)
90 (3.54) 90
(3.54)
110 42 (1.65)
(4.33)
130 (5.12)
H filter
element
length
90
(3.54)
106 (4.17)
W Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 55
In-tank Filters Flows to 105 L/min (27.7 USgpm)
Pressures to 10 bar (150 psi)
OFRT250 Series
Flow Data
Sample P Calculation : OFRT2501COSAG7A06T - Filter assembly having filter element with micron rating code '06'
at 100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.01 x 0.8/0.9 + 0.3 x 46/32 x 0.8/0.9
= 0.008 + 0.38
= 0.49 bar
56 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
In-tank Filters Flows to 480 L/min (126.8 USgpm)
Pressures to 10 bar (150 psi)
OFRT630 Series
High efficiency filter Rated flow: Length 1 320 L/min (84.5 USgpm)
Length 2 400 L/min (105.7 USgpm)
elements with superior Length 3 440 L/min (116.2 USgpm)
dirt-holding capacity Length 4 480 L/min (126.8 USgpm)
designed for return lines Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water
and installed semi- and water-in-oil fluids, Optional seals available for phosphate esters.
immersed in a reservoir Temp range: -25C to 110C (-13F to 230F)
Excellent pressure drop Pressure rating: Operating 10 bar (150 psi)
characteristics Fatigue 10 bar (150 psi)
Indicators ordered Material: Head Die Cast Aluminum
separately Cover Aluminum
Dry weight: Length 1 8,2 kg. (18.1 lbs.)
Bowl length options for (Approximate) Length 2 8,7 kg. (19.2 lbs.)
design flexibility Length 3 9,0 kg. (19.8 lbs.)
Easy element changes Length 4 9,5 kg. (20.9 lbs.)
Bypass valve prevents
excessive pressure drop
and prevents element
collapse and release of
retained contaminant's OFRT630 * C * S * F* A** T
back into hydraulic
system 1 2 3 4 5 6 7 8 9
Designed to comply with
ISO standards 1 5 8
Filter Series - OFRT 630 Breather Options Fluid Cleanliness Rating
S - No breather Target fluid
2 Assembly Length Code cleanliness level
OFRT 630 Series mm (inch) 6 Seal Material A06 18/16/14 or better
Filter and Element 1- 400 (15.7) A - Buna-N A10 20/18/15 or better
Model Code 2- 480 (18.8) V - Viton-A
3- 580 (22.8) 9 Indicator Options
4- 670 (26.4) 7Port Options
Sample model code: T - No Indicator (plug), No
Length given does not include diffuser F1 - 2-1/2 in SAE Flange Code
OFRT6301COSAF3A06T Connector
61 with metric bolts
3 Bypass Options F2 - 2 in and 2-1/2 in SAE
C - Bypass set at 1.7 bar Flange Code 61 with
(25 psi) cracking pressure metric bolts (dual)
F3 - 2-1/2 in SAE Flange Code
4 Diffuser Options 61 with UNC bolts
O - No diffuser F4 - 2 in and 2-1/2 in SAE
D - With diffuser Flange Code 61 with
UNC bolts
Items not in bold are non-standard and may have a longer lead time
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 57
In-tank Filters Flows to 480 L/min (126.8 USgpm)
Pressures to 10 bar (150 psi)
OFRT630 Series
FT630 * A** *
1 2 3 4
Housing
D Dimensions
mm (inch)
Port B (8.46)
M10
182
(7.17)
215
(8.46) 11 (0.43)
166,5/167,0 (6.56/6.57) 90
110
110 (4.33) (4.33)
E
140 55 (2.17)
(5.51) D
C
G
165 (6.50)
14
163 (6.42) (0,55)
H
filter
element
length
110
(4.33)
126 (4.96)
With Without
Diffuser Diffuser
Items not in bold are non-standard and may have a longer lead time
58 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
In-tank Filters Flows to 480 L/min (126.8 USgpm)
Pressures to 10 bar (150 psi)
OFRT630 Series
Flow Data
Sample P Calculation : OFRT6301COSAF3A06T - Filter assembly having filter element with micron rating code '06'
at 300 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.02 x 0.8/0.9 + 0.6 x 46/32 x 0.8/0.9
= 0.017 + 0.76
= 0.77 bar
High efficiency filter Rated flow: Length 1 650 L/min (171.7 USgpm)
Length 2 1000 L/min (264.2 USgpm)
elements with superior Length 3 1200 L/min (317.0 USgpm)
dirt-holding capacity Length 4 1500 L/min (396.3 USgpm)
designed for return lines Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water
and installed semi- and water-in-oil fluids, optional seals available for phosphate esters.
immersed or totally Temp range: -25C to 110C (-13F to 230F)
immersed in a reservoir
Pressure rating: Operating 10 bar (150 psi)
Excellent pressure drop Fatigue 10 bar (150 psi)
characteristics Material: Head Die Cast Aluminum
Indicators ordered Cover Steel
separately Dry weight: Length 1 30 kg. (66.14 lbs.)
(Approximate) Length 2 34 kg. (74.96 lbs.)
Bowl length options for Length 3 37 kg. (81.57 lbs.)
design flexibility Length 4 41 kg. (90.39 lbs.)
Easy element changes
Bypass valve prevents
excessive pressure drop
and prevents element
collapse and release of
retained contaminant's OFRT850 * C * S * F3 A** T
back into hydraulic
system
1 2 3 4 5 6 7 8 9
Designed to comply with
ISO standards
1 Filter Series - OFRT 850 5
Breather Options 8 Fluid Cleanliness Rating
S - No breather Target fluid
2 Assembly Length Code cleanliness level
OFRT 850 Series mm (inch) 6 Seal Material A06 18/16/14 or better
Filter and Element 1- 572 (22.5) A - Buna-N A10 20/18/15 or better
Model Code 2- 787 (31.0) V - Viton-A
3- 1067 (42.0) 9 Indicator Options
4- 1332 (52.4) 7
Port Options
Sample model code: T - No Indicator (plug), No
F3 - DN 100 PN 10/16 3" Connector
OFRT8501COSAF3A06T 3 Bypass Options SAE/Metric Bolt Holes
C - Bypass set at 1.7 bar
(25 psi) cracking pressure
4 Diffuser Options
O - No diffuser
D - With diffuser
FT850 * A** *
1 2 3 4
Element model code 1 Filter Element - FT 850 3 Fluid Cleanliness Rating 4 Seal Material
Target fluid A - Buna-N
Sample model code: 2 Element Length Code cleanliness level V - Viton-A
mm (inch) A06 18/16/14 or better
FT8502A06A
1- 388 (15.2) A10 19/17/14 or better
2- 603 (23.7)
3- 883 (34.7)
4- 1148 (45.2)
Housing Dimensions
mm (inch)
Port B
G Port B
320 (12.60)
Port A
210 210
(8.27) 22 30
(8.27)
Port B 45
E
76 (2.99)
D 184
(7.24) 180 (7.09)
C 100
247 (9.72) (3.94)
M10
15 220 (8.66)
H (0.59)
filter
250 (9.84) element
length
203 (7.99) 45
251,5/252,0
(9.90/9.92)
295 (11.61)
M12
Sample P Calculation : OFRT8501COSAF3A06T - Filter assembly having filter element with micron rating code '06'
at 500 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.02 x 0.8/0.9 + 0.3 x 46/32 x 0.8/0.9
= 0.017 + 0.38
= 0.39 bar
1 2 3 4 5 6
Length 3
Length 1 75
70 (2.85)
(2.76) 31
Length 1 34 (1.22)3
27 (1.34)
(1.06)
Indicator
Port
G 1/8
Length 1 Length 3
86 171
(3.39) Length 2
(6.73)
204.8
(8.06)
Length 4
288.8
(11.37)
18
(0.71)
smooth outlet
Length 1
60 Hose Barb
(2.36) 25
(1.00)
32
Length 1 ( 1.26) 107
(4.21)
10
( 0.39) L Length 5 Length 6 & 7
Length 2 & 4 Length 3 124 167
60 73.4 62 (4.88) (6.57)
( 2.36) (2.89) (2.24)
43 Length
(1.693) 2&4
11
(0.47)
Length 5
Length 12
5 3 (0.47)
( 0.20) 8.5
Length Length (0.34) Length 6 & 7
2&4 3 13.5
112 90 (0.53)
78 Length 5 Length 6 & 7
(4.41) (3.54) 177 220
(3.07) (6.97) (8.66)
Length 5
172 Length 6
(6.77) 300
(11.81)
Length 7
3.81
(15.00)
Threaded
Outlet
G 2
122
(4.80) Threaded Outlet
G 2 1/2
165
( 6.50)
6,0
,25 69
Pressure drop - psid
0,2
3
,15 4.0 59
0,1 2 54
1 49
,05
3.0 44
0,0 0
0 40 80 120 160 39
Flow Rate - L/min 34
2.0 29
0 20 40 60 80 100.0 120.0 140.0 160.0
Flow Rate - L/min
67.5
Pressure drop - psid
6
Pressure drop - psid
0,3 5 63.5
4 59.5
0,2 4.0
3 55.5
2 51.5
0,1
1 47.5
0 0 3.0 43.5
0 38 76 114 170 0 25 50 75 100 125 150 175 200
,25
ORFM Length 6 & 7 Housing ORFM Length 6 & 7 Bypass Flow Rate - L/min
3.6 51.0
4 3.5
0,2 3.4 49.0
3 3.3 47.0
,15 3.2
2 3.1 45.0
0,1
3.0 43.0
,05 1 2.9
2.8 41.0
0,0 0
0 100 200 300 400 500 600 700 800 0 50 100 150 200 250 300 350 400
Flow Rate - L/min Flow Rate - L/min
Sample P Calculation : ORFM1SA2LNB1C05X - Filter assembly having '1' length filter element with micron rating
code '05' at 25 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.6 x 0.8/0.9 + 25 x 0.044 x 46/32 x 0.8/0.9
= 0.520 + 1.39
= 1.91 bar
Beta Ratio: x(c) = 1000 Rated flow: 1300 L/min (343 USgpm)
to ISO 16889 Fluid compatibility: Compatible with all petroleum oils and synthetic fluids rated for use with
Fluoro-Rubber or Ethylene Propylene seals.
Non-welded housing
design reduces stress Temp range: -30C to + 121C (-22F to 250F)
concentrations prevents Pressure rating: Operating 25 bar (360 psi)
fatigue failure Fatigue 25 bar (360 psi)
O-ring seals are used to Material: Housing, Lid, Transfer Valve: Ductile Iron
provide positive, reliable Dry weight: 43kg (94.8 lbs)
sealing (Approximate)
Bolt-on lid requires
minimal clearance for
removal
Reusable contamination
basket prevents loss of
retained contaminants into
the reservoir during
element replacement
ORF 1 F * ** * 1 * **
Clogging indicators can
be serviced without
1 2 3 4 5 6 7 8 9
interruption of the
hydraulic system
1 Filter Series - ORF MK - Electrical 1 bar (15 psi), UH - Electrical 4.9 bar
Single piece casting
Hirschmann w 115 volt (70 psi), Hirschmann
provides rigidity for inline light GA - Gauge 0-4 Bar (0-60 psi).
2 Element Collapse Rating
or in-tank mounting ML - Electrical 1 bar (15 psi), Use with valve option 1
1 - 17 bar (250 psi) Low Hirschmann w 230 volt GB - Gauge 0-10 Bar (0-160
ORF 1300 Series Collapse light psi).
Filter and Element 3
MH - Electrical 1 bar (15 psi), Use with valve option 2
Port Options Hirschmann
Model Code
F - 4" SAE Flange, Code 61 RB - Electrical 2 bar (30 psi), 6 Seal Material
Brad Harrison B - Buna-N
Sample model code: 4 Valve Options RJ - Electrical 2 bar (30 psi), V - Viton-A
ORF1F2JNB1C05 0 - Non-Bypass Hirschmann w 24 volt
1 - Bypass set at 1.7 bar light 7 Assembly Length
(25 psi) cracking pressure RK - Electrical 2 bar (30 psi), mm (inch)
2 - Bypass set at 2.9 bar Hirschmann w 115 volt 1 - 584 (23.0)
(43 psi) cracking pressure light
3 - Bypass set at 5.9 bar RL - Electrical 2 bar (30 psi), 8 Element Construction
(87 psi) cracking pressure Hirschmann w 230 volt
C - Standard Construction
light
5 Indicator Options*
X - no element
RH - Electrical 2 bar (30 psi),
AN - Visual 4.9 bar (70 psi), Hirschmann 9 Fluid Cleanliness Rating
No Connector UB - Electrical 4.9 bar
Target fluid
KN - Visual 1 bar (15 psi), (70 psi), Brad Harrison Code cleanliness level
No Connector UJ - Electrical 4.9 bar
(70 psi), Hirschmann 03 16/14/12 or better
LN - Visual 2 bar (30 psi),
No Connector w 24 volt light 05 18/16/14 or better
JN - No Indicator (plug), UK - Electrical 4.9 bar 10 20/18/15 or better
No Connector (70psi), Hirschmann 20 22/19/16 or better
MB - Electrical 1 bar (15 psi), w 115 volt light XX no element
Brad Harrison UL - Electrical 4.9 bar (70 psi),
MJ - Electrical 1 bar (15 psi), Hirschmann w 230 volt
Hirschmann w 24 volt light
light * For indicator options, refer
to Static Indicators on page
V209 1 * 8 C **
1 2 3 4 5 6
Element model code 1 Filter element - V209 4 Element Length 6 Fluid cleanliness rating
mm (inch) Target fluid
Sample model code: 2 Element Collapse Rating 8 - 253 (9.96) Code cleanliness level
V2091B8C10 1 - 17 bar (250 psi) Low 03 16/14/12 or better
5 Element construction
Collapse 05 18/16/14 or better
C - Standard Construction 10 20/18/15 or better
3 Seal material
20 22/19/16 or better
B - Buna-N
V - Viton-A
Housing Dimensions
mm (inch)
Mounting Pattern
460
(18.11)
Clearance required
for element changeout Indicator Port 290
G 1/2 (11.42) 18
(0.71)
253
(9.96) 208
(8.19)
584
(22.99)
121
(4.76)
255
(10.04)
4.8 70.0
0,12
1.5
Pressure Drop - psi
0,10
4.3
60.0
0,08
1.0 3.8
0,06
50.0
0,04 3.3
0.5
0,02
2.8 40.0
0 0 0 50 100 150 200 250 300 350 400
0 300 600 900 1200 1400
Flow Rate - L/min
Flow Rate - L/min
Sample P Calculation : ORF1F2JNB1C05 - Filter assembly having '1' length filter element with micron rating code
'05' at 200 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.01 x 0.8/0.9 + 200 x 0.001 x 46/32 x 0.8/0.9
= 0.008 + 0.25
= 0.26 bar
DRT 1 *** ** 4 ** N * * **
1 2 3 4 5 6 7 8 9 10
DRT Series Filter 1Filter Series BE - G 1 1/4 (Length 160 only) 8 Seal Material
BF - G 1 1/2 (Length 250 only)
DRT - DIN In-Tank B - Buna-N
Sample model code: BM - 2 1/2 in SAE Flange
V - Viton-A
2 Code 61 with metric
DRT1100BD4XXNBC06 Element Collapse Rating
bolts (DN 64) (Length 9
1 - Low Collapse Element Construction
400 and 630 only)
C - Standard Construction
3 Nominal Size 5 X - no element
Valve Options
040 - 40 L/min (11USgpm) 4 - Bypass set at 3 bar (50 psi) 10Fluid Cleanliness Rating
063 - 63 L/min (17USgpm) cracking pressure
100 - 100 L/min (26USgpm) Target fluid
160 - 160 L/min (42USgpm) 6 Code cleanliness level
Indicator Options *
250 - 250 L/min (66USgpm) 03 16/14/12 or better
XX - No Indicator
400 - 400 L/min (106USgpm) 06 18/16/14 or better
GB - 0-10 bar (0-145 psi) gauge
630 - 630L/min (166USgpm) 10 20/18/15 or better
RH - Electrical switch
4 Hirschmann 25 22/19/16 or better
Port Size
BB - G 1/2 (Length 040 only) 7
XX no element
Secondary Port
BC - G 3/4 (Length 063 only)
N - No Secondary Port
BD - G 1 (Length 100 only)
VDT *** * C **
1 2 3 4 5
Element model code 1 Filter Element 3 Seal Material 5 Fluid Cleanliness Rating
VDT - DIN Standard Element B - Buna-N Target fluid
Sample model code: V - Viton-A Code cleanliness level
2 Nominal Size 03 16/14/12 or better
VDT250BC06 4
040 - 40 L/min (11USgpm) Element Construction 06 18/16/14 or better
063 - 63 L/min (17USgpm) C - Standard Construction 10 20/18/15 or better
100 - 100 L/min (26USgpm) 25 22/19/16 or better
160 - 160 L/min (42USgpm)
250 - 250 L/min (66USgpm)
400 - 400 L/min (106USgpm)
630 - 630L/min (166USgpm)
Dimensions DRT 040, 063, 100 Series
Dimensions in mm
72 b1 Minimum Clearance
55 h2
For Element Removal
93
43 34
Inlet
Connection for
indicator
84
h1
138.5
73
M-10
115
138.5
Dimensions in mm
h1 Minimum for
element removal Connection for
indicator
37
106.5
47
Inlet
101 91
Outlet
M-10 185
187
b1
182
H drop:
Flow versus pressure DRT 040/063/100
0.07
32 cSt oil with specific gravity of 0.9
(See page 5 for specific gravity corrections for pressure drop.) 0.06
p [bar]
DRT 040 G 1/2 81 122 150
DRT 063 G 3/4 70 206 200 0.04
DRT 100 G1 70 260 290
0.03
0.02
0.01
0.00
0 20 40 60 80 100
Q in l/min
0.04
0.02
0.00
0 50 100 150 200 250
Q in l/min
1.5 Element size 100 1.5 Element size 160 Element size 250
3m
3m 1.75
1.25 1.25 1.5
p [bar]
p [bar]
1 1 1.25
p [bar]
0.75 6m 0.75 1 6m
3m
0.75 10m
0.5 0.5 6m
10m 0.5 25m
0.25 0.25 10m
25m 25m 0.25
0 0 0
0 50 100 150 200 0 50 100 150 200 0 100 200 300 400 500 600
flow rate [l/min] flow rate [l/min]
flow rate [l/min]
Element size 400 Element size 630
1.75 2.5 3m
1.5 2
1.25 3m
p [bar]
p [bar]
1 1.5 6m
6m
0.75 1 10m
10m 25m
0.5 25m
0.5
0.25
0 0
0 100 200 300 400 500 600 0 200 400 600 800 1000 1200
flow rate [l/min] flow rate [l/min]
Sample P Calculation : DRT1100BD4XXNBC06 - Filter assembly having filter element with micron rating code '06' at
100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.065 x 0.8/0.9 + 0.3 x 46/32 x 0.8/0.9
= 0.057 + 0.38
= 0.43 bar
Pop-rivets for
shipping purposes
only. Remove prior
to installation.
Beta Ratio: x(c) = 1000 Rated flow: Length 3 189 L/min (50 USgpm)
to ISO 16889 Length 6 379 L/min (100 USgpm)
Length 7 454 L/min (120 USgpm)
Designed to comply with Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids
ANSI specifications and Optional seals available for phosphate esters.
ISO cleanliness standards. Temp range: -30C to 121C (-22F to 250F)
Conforms to HF4 Pressure rating: Operating 7 bar (100 psi)
specifications Fatigue 7 bar (100 psi)
Gauge and electrical Material: Head Aluminum
switch options available to Cover Aluminum
monitor element loading Bowl Carbon Steel
Dry weight: Length 3 4,5 kg. (10.0 lbs.)
In-tank configuration (Approximate) Length 6 6,6 kg. (14.5 lbs.)
minimizes space Length 7 8,4 kg. (18.6 lbs.)
requirements and potential
system leakage points
Optional secondary
port allows filtration of a
second return line without
additional fittings or
filtered fill port
High efficiency
replacement elements in
standard configurations (C-
Pak) to meet Target
Cleanliness Levels. HF4RT 1 ** * ** * ** * * **
Optional extend tube
allows smaller filtration unit
1 2 3 4 5 6 7 8 9 10
to be used where needed
HF4RT Series 1 Filter Series - HF4RT 5 Indicator Options* SZ - 2.50 - 12 UN SAE-32 str.
Filter and Element Thd. (2" tube) - use with
XX - No indicator
Model Code 2 FE Inlet Port
Element Collapse Rating GA - Gauge 0-4 bar (0-60psi)
XX - No Secondary Port
1 - 10 bar (150 psi) Low GB - Gauge 0-10 bar (0-160psi) Note: No secondary port option is available
Sample model code: Collapse MB - Electrical, 15 PSI with the ME inlet port option.
Brad Harrison
HF4RT1SD313XXBC05 3 Port Options RB - Electrical, 30 PSI 8 Seal Material
BC - G11/4 to ISO 228 Brad Harrison
B - Buna-N
ME - 11/2" - SAE 4 bolt Flange MH - Electrical, 15 PSI V - Viton-A
Code 61 (M12 x 1.75) Hirschmann
SD - 1.875 - 12 UN SAE-24 RH - Electrical, 30 PSI 9 Element Construction
str. Thd. (11/2" tube) Hirschmann
C - Standard Construction
FE - 11/2" - SAE 4 bolt Flange 6 X - no element
Code 61 (UNC) Assembly Length
mm (inch)
10 Fluid Cleanliness Rating
4 Valve Options 3 - 378 (14.9)
6 - 584 (23) Target fluid
3 - Bypass set at 1.7 bar 7 - 787 (31) Code cleanliness level
(25 psi)
cracking pressure 03 16/14/12 or better
7 Secondary Port
4 - Bypass set at 3 bar 05 18/16/14 or better
(43 psi) cracking BC - G11/4 to ISO 228 - use 10 20/18/15 or better
pressure with BC Inlet Port
SD - 1.875 - 12 UN SAE-24 20 22/19/16 or better
str. Thd. (11/2" tube) - XX no element
use with SD Inlet Port
* For indicator options, refer to Static Indicators on page 150.
V405 1 * * C **
1 2 3 4 5 6
Housing Dimensions
mm (inch)
112.2
(4.42)
56.1 M10 or
(2.21) 3/8"-20 thread
4 PL'S
Equally
spaced
112.2
(4.42) 127
(5.0")
158.75
(6.25)
Secondary 118.5
port
(4.67)
Indicator port
1/8 NPT 53.6
(2.11)
Refer to
Model Code
"ME" port - M12 x 1.75
"FE" port - 1/2 - 13UNC (4 places)
69.8
(2.75) 35.7
(1.41)
Outlet port
Length Connection
3 1" Hose 38.1 (1.5)
6 1 1/2" NPT SAE-4 bolt
124.6 flange code 61
(4.9) 7 1 1/2" NPT
Inlet Flange
0,6 3,5
3,0 3,0
0,4 6 25 PSI
2,5
2,0 2,0
0,2
1,5
0
0 100 200 300 400 0 100 200 300 400
Flow Rate - L/min Flow Rate - L/min
Sample P Calculation : HF4RT1SD3XX3XXBC05 - Filter assembly having '3' length filter element with micron rating
code '05' at 200 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.15 x 0.8/0.9 + 200 x 0.003 x 46/32 x 0.8/0.9
= 0.130 + 0.76
= 0.89 bar
OSS Suction
Strainers
OSS * * 1 M
1 2 3 4 5
Items not in bold are non-standard and may have a longer lead time
80 EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007
In-tank Filters
OSS Suction
Strainers
Flow Data
1 1/4
.3 .02 .3 .02
1 1/2
0 0
0 10 20 30 40 50 60 70 80 90 110 120 0 10 20 30 40 50 60 70 80 90 110 120
Flow Rate - USgpm Flow Rate - USgpm
.3 .02 .3 .02
0 0
0 10 20 30 40 50 60 70 80 90 110 120 0 10 20 30 40 50 60 70 80 90 110 120
Flow Rate - USgpm Flow Rate - USgpm
OTM Tank
Mounted
Strainers
DESIGN SPECIFICATIONS
MODEL
CODE A B C D E SCREEN AREA RATED FLOW
Port Size mm (in) mm (in) mm (in) (sq. cm) (sq.inch) L/min & USgpm
OTM1 1" NPT 1/2" NPT 135.6 (5.3) 26.9 (1.06) 29.7 (1.1) 225.75 35 19 5
OTM2 1 1/4" NPT 3/4" NPT 207.5 (8.2) 30.4 (1.2) 34.5 (1.3) 412.80 64 38 10
OTM3 1 1/2" NPT 1" NPT 208.2 (8.2) 30.9 (1.2) 42.1 (1.6) 554.70 86 57 15
OTM4 2" NPT 1 1/4" NPT 229.6 (9.0) 34.2 (1.3) 53.8 (2.1) 806.25 125 95 25
OTM5 3" NPT 2" NPT 246.3 (9.7) 43.1 (1.7) 76.2 (3.0) 1677 260 190 50
OTM6 4" NPT 3" NPT 287 (11.3) 45.7 (1.8) 101.6 (4.0) 2031.75 315 380 100
OTM1 5003895
OTM2 5003896
OTM3 5003897
OTM4 5003898
OTM5 5003899
OTM6 5003900
General Data detrimental to pump pressure drop gets into the Switch Circuit
operation. danger zone. Red indicates
These units have been an open bypass valve. The GREEN
designed for use in the The unit may be mounted in
any position desired. To indicator will also
intake lines of hydraulic automatically show red, BLUE
pumps to afford a degree of ensure proper operation of
the air bleed feature, (bypass condition) if the unit
protection from is accidentally operated RED C
NC
** F * 1 ** * * * * **
1 2 3 4 5 6 7 8 9 10
7 Seals
B - Buna - N
V - Viton
52,4
(2.06) 114,3
(4.50) Visual
57,2 indicator
(2.25)
25,4 two places
(1.00)
SAE Flange Ports Mechanical Indicator Electrical Indicator
139,7 Memory
(5.50) reset knob
82,6 53,8
(3.25) 1/ " NPTF
2 thd. (2.12)
215,9
(8.50)
Clearance 203,2
required for 35,0 (8.00)
removal of (1.38) 203,2
cartridge 153,9 (8.00)
(6.06)
70,0 In In
(2.75)
50,0
(1.97)
Wrench
flats Inlet port Out Out
31,7 31,7 35,0
(1.25) (1.25) 70,0 (1.38)
Outlet port (2.75) For proper air bleed
operation, center line
must be horizontal with
Threaded Ports inlet port pointed down.
419.4 (65) 1" NPTF G1 (1" BSPF) 1.312-12 UN 1.000 FLI-8-08P-10 FLI-8-08W-10
*Not recommended
C
D 165,1
(6.50) Visual
82,6 indicator
(3.25)
E two places
196,8 Memory
(7.75) reset knob
114,3 1/ " NPTF 53,8
2 (2.12)
(4.50) thd.
358,6 304,8
(14.12) 57,1 (12.00)
Clearance
required for (2.25)
304,8
removal of 255,8 (12.00)
cartridge (10.07)
114,3 In In
(4.50)
87,4
(3.44)
Wrench
flats Out
57,1 Inlet port Out Out
(2.25) 57,15
57,1 (2.25)
Outlet port 114,3
(2.25) (4.50) For proper air bleed
Threaded Ports operation, center line
must be horizontal with
inlet port pointed down.
INLET AND OUTLET PORT THREADS SAE FLANGE PORT DIMENSIONS
ELEMENT SAE
AREA PIPE STRAIGHT TUBE NPTF WELDED
MODEL CM2 (IN2) THREAD* THREAD SIZE FLANGE* FLANGE A B C D E
50FB 645,2 (100) 11/2" 1.875-12 UN 1.50 FLI-12-12P-10 FLI-12-12W-10 35,7 (1.41) 17,8 (0.70) 35,1 (1.38) 69,8 (2.75) 38,1 (1.50)
50FC 1419,4 (220) 2" 2.500-12 UN 2.00 FLI-16-16P-10 FLI-16-16W-10 42,9 (1.68) 21,3 (0.84) 38,9 (1.53) 77,8 (3.06) 50,8 (2.00)
50FD 1419,3 (220) 21/2" - - FLI-20-20P-10 FLI-20-20W-10 50,8 (2.00) 25,4 (1.00) 44,4 (1.75) 88,9 (3.50) 63,5 (2.50)
*Not recommended
General Data
Spin-on filters typically consist of a head mounted
directly in-line with the return piping and a canister
These are an effective and economical choice of filter
containing an element which screws onto a threaded
where the return line pressure is low and there are no
post. The canister seals to the head to prevent
large flow surges with the return line. They are also
leakage.
easily installed without specialty equipment or tooling.
Applications
Agricultural equipment -
tractors, spreaders,
harvesters
Metal forming presses
Strapping systems
Brush Chippers
Turf maintenance equipment
Small power units
OFRS 15 * * *** * * * ** 10
1 2 3 4 5 6 7 8 9 10
V019 1 B * R **
1 2 3 4 5 6
Housing Dimensions
26,9 26,9 .375-16 UNC-2B thd. 19,1 (0.75) min. full thd.
mm (inch) (1.06) (1.06) 2 holes for mounting Mounting screw torque
20-27 Nm (15-20 ft-lb)
B Pressure gauge 3,05R (0.12R) Typ.
connection
E Pressure gauge connection1/8" NPTF pipe thd.
2 locations (see Model Code)
47,8
(1.88) 27,2 (1.07)
13,5
(0.53)
23,9
(0.94) 11,2 9,53/9,78R (0.375/0.385R) Typ.
11,2
(0.44) 7,87R (0.44)
(0.31R)
98,8
Optional pressure gauge (3.89)
49,3 44,4
(1.94) (1.75) Hex. - both ends
24,4
Approx. (0.96)
55,9
(2.20)
Std.
Inlet Outlet (length 1)
port port 194,6
(7.66)
Long
(length 2)
250,4
(9.86)
Std.
(length 1)
170,2
(6.70)
Long
(length 2)
226,1
(8.9)
40
Pressure drop - bar
35 2,5 36
30
25 2,0
20
15 1,5 22
10
5 0,5
0
9.5 19 28 38 47 57 66 76 85 95
Flow Rate - L/min 50 100 150 200
Flow Rate - L/min
Sample P Calculation : OFRS15S2R03PBE1010 - Filter assembly having '2' length spinon filter element with micron
rating code '03' at 50 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific
gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.4 x 0.8/0.9 + 0.08 x 46/32 x 0.8/0.9
= 0.350 + 0.1
= 0.45 bar
OFRS 25 * * *** * * * ** 10
1 2 3 4 5 6 7 8 9 10
OFRS25 Series 1 Filter Series - OFRS 5Fluid Cleanliness Rating 8 Outlet Gauge Port
Filter and Element Target fluid Location (1/8" NPTF)
Model Code 2 Flow Rating Code cleanliness level D - Location D
25 - 25 USgpm (95 L/min) R03 16/14/12 E - Location E
Sample model code: R05 18/16/14 F - Location F
3 Port Type R10 20/18/15 X - No Gauge
OFRS25S1R03PAF2510 NOTE: Gauges cannot be mounted side by
B - G1 (formerly 1" BSPF) thd. XXX no element side. If inlet and outlet gauges are required,
F - 1" SAE-4-bolt flange code 61 specify non-adjacent ports such as A and E.
P - 1" NPTF 6 Pressure Gauge Option
S - 1.312-12 UN SAE-16
P - Pressure gauge 0-120 psi 9 Bypass Valve
straight thd. for 1" OD tube
(0-8 bar); p/n 736129 XX - Non-bypass
4 Assembly Length X - No Gauge 25 - Bypass valve set at
mm (inch) 1.7 bar (25 psi)
7Inlet Gauge Port Location
1 - 194,1 (7.6)
2 - 250,4 (9.9) (1/8" NPTF) 10 Design Number
X - no element A - Location A 10 - Standard Design
B - Location B
C - Location C
X - No Gauge
V019 1 B * R **
1 2 3 4 5 6
Housing Dimensions .375-16 UNC-2B thd. 15,7 (0.62) min. full thd.
mm (inch) 4 holes for mounting
53,8 Mounting screw torque 20-27 Nm (15-20 ft-lb)
(2.12)
26,9 F Pressure gauge connection
(1.06) 1/8" NPTF pipe thd.
C
6 locations (see Model Code)
B E
40,4
(1.59)
81,0
(3.19)
Approx.
66,7
(2.62)
D 23,9 47,6
(0.94) (1.88)
97,5
12,7 Clearance required for removal of cartridge (3.84)
(0.50)
R05
0,4 R03 0,4 6
6
R05
0,2 4 0,2 4
R10
0,1 R10 0,1 2
2
0 0
0 10 20 30 40 50 60 70 0 20 40 60 80 100 120 140
Flow Rate - L/min Flow Rate - L/min
3,0
2,0
1,5 22
0,5
Sample P Calculation : OFRS25S1R03PAF2510 - Filter assembly having '1' length spinon filter element with micron
rating code '03' at 70 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific
gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.25 x 0.8/0.9 + 0.42 x 46/32 x 0.8/0.9
= 0.220 + 0.53
= 0.75 bar
1 2 3
OFSS30B2 5003904
OFSS30E2 5003905
V176 C B ***
1 2 3 4
V176CBRO5 5003901
V176CBR10 5003902
V176CBW15 5003903
(1.2)
(2.1)
Housing Dimensions
mm (inch)
3 .20
10
.15
2
.10
5
1
.05
0 0 .00
0 5 10 15 20 25 30 35 0 5 10 15 20 25 30
Flow (USgpm) Flow (USgpm)
(L/min)
0 25 50 75 100
(L/min)
0 25 50 75 100
20 bar 40 bar
2.5
1.2
15 1.0 30 2.0
Pressure Drop (psi)
0.8
1.5
10 20
0.6
1.0
0.4
5 10
0.5
0.2
0 0.0 0 0.0
0 5 10 15 20 25 30 0 5 10 15 20 25 30
Flow (USgpm) Flow (USgpm)
Ideal for charge pump Rated flow: 130 L/min (35 USgpm)
applications and hydrostatic Fluid compatibility: Compatible with most petroleum oil, water glycol,
transmissions oil-in-water and water-in-oil fluids.
Spin-on element design Temp range: -29C to +121C (-20F to +250F)
for easy maintenance Pressure rating: Operating 35 bar (500 psi)
One port available for use Fatigue 35 bar (500 psi)
with electric indicator Material: Head Die cast aluminum
Bypass valves prevent Bowl Steel, cold rolled
excessive pressure Dry weight: (Approximate) Length 1 1,0 kg (2.2 lbs.)
drop and accidental Length 2 2,2 kg (4.8 lbs.)
element collapse
Filter Head and Element must be ordered separately for OFRP35 Filters.
OFRP 35 ** * **
1 2 3 4 5
VI 25 5002470
EL25DC 5002471
EL25ACDC 5002472
EL50DC 5002473
1 2 3 4 5
V0311 Element Sample model code: 1 Filter Element 5 Fluid Cleanliness Rating
Model Code V0311B2R05 V0311 - Filter element for use Target fluid
with OFRP35 only Code cleanliness level
MODEL CODE: PART
NUMBER 05 18/16/14
2 Seal material
VO311B1R05 5002474 08 19/17/14
B - BunaN
VO311B2R05 5002475 12 20/18/15 (length 2 only)
VO311B2R12 5002476 3 18 22/19/16
Element Length
VO311B1R08 5002477 mm (inch) Fluid Cleanliness Rating:
VO311B2R08 5002478 1 - 147 (6.0) 05, 08, 18 rated for 150 PSID
2 - 203 (9.4)
VO311B1R18 5002479 collapse, 12 rated for 300 PSID
VO311B2R18 5002480 4 collapse and recommended for
Element Construction
ST port type
Housing Dimensions R - R-Pak
mm (inch) OFRP35 with optional electrical indicator OFRP35 with optional electrical indicator
35,1 35,1
(1.38) 3/8-16UNC-28
x .60 Min Thd (1.38) 3/8-16UNC-28
4-Plcs x .60 Min Thd
4-Plcs
OFRP35 with B1 Length Filter Element OFRP35 with B2 Length Filter Element
101,6 (4.00) 101,6 (4.00)
34,0
(1.34) 34,0
(1.34)
Visual Indicator
5002470
214,9
(8.46)
WIRING DIAGRAM 151,6
303,0 (11.93)
Differential
Pressure
To Remove Spin-on Assy.
Flow - USgpm
0 5 10 15 20 25 30 35 40 45 50 55 60
1,0 15
Pressure Drop - bar
0,7 10
OFRP35P
OFRP35B & OFRP35S
0,3 5
0 0
0 25 50 75 100 125 150 175 200 225
Flow (L/min)
IN OUT IN OUT
Available with Vickers Rated flow: Length 1 114 L/min (30 USgpm)
proprietary R-Pak media Length 2 227 L/min (60 USgpm)
Fluid compatibility Compatible with most petroleum ol, water glycol,
Simple spin-on element oil-in-water and water-in-oil fluids
design for easy
Temp range: 40C to +107C (-40F to +225F)
maintenance
Pressure rating: Operating 7 bar (100 psi)
Optional bypass valves
Material: Head Die cast aluminum
prevent excessive Canister Carbon steel
pressure drop and
Dry weight: Length 1 4,4 kg (5.0 lbs)
accidental element Length 2 5,6 kg (6.5 lbs)
collapse
Six available ports for use
as gauge and/or
diagnostic ports
H20-Pro Water Removing
Element available
OFRS 60 * * * * ** * * * ** 10
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6
Housing Dimensions
OFRS-60
Body or Line Mounting
mm (inch)
Length 2
312,7
(12.31)
128,5
136,5 (5.06)
33,3 (1.31) Clearance required for removal of cartridge (5.38)
Inlet
port Outlet
port 17,8
(0.70)
10,3 (0.41)
Optional Thru holes for
pressure mounting 211,1
gauge (8.31*)
128,5
(5.06)
136,5
33,3 (1.31) Clearance required for removal of cartridge (5.38)
* Add 101,6 (4.00) for long 10mm element.
0,4 6 0,4 6
R05 R05
0,3 0,3
R10 R10
0,2 3 0,2 3
R20 R20
0,1 0,1
0 0
0 25 50 75 100 125 150 0 50 100 150 200 250 300
Flow Rate - L/min Flow Rate - L/min
3,0
Pressure drop - psid
Pressure drop - bar
0,4
2,5 36
0,3
2,0
0,2 3
1,5 22
0,1 0,5
0
0 75 150 225 50 100 150 200
Flow Rate - L/min Flow Rate - L/min
Sample P Calculation : OFRS601S1R03PAF2510 - Filter assembly having '1' length filter element with micron rating
code '03' at 100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.11 x 0.8/0.9 + 0.29 x 46/32 x 0.8/0.9
= 0.090 + 0.36
= 0.45 bar
Designed to comply with Rated flow: Length 1 227 L/min (60 USgpm)
ANSI specifications and Length 2 454 L/min(120 USgpm)
ISO cleanliness standards Fluid compatibility Compatible with most petroleum ol, water glycol,
oil-in-water and water-in-oil fluids
Dual flow path design Temp range: -32C to +107C (-25F to +225F)
maximizes flow capability
Pressure rating: Operating 14 bar (200 psi)
and service life
Material: Head Aluminum
Spin-on element make
servicing fast and easy Dry weight: Length 1 7.3 kg (16 lbs)
Length 2 8.6 kg (19 lbs)
High efficiency
replacement elements in
standard configurations
(R-Pak) to meet Target
Cleanliness Levels
HS22 1 ** * * N B * * **
1 2 3 4 5 6 7 8 9 10
V021 1 B * * **
1 2 3 4 5 6
60 165,5
146 (6.52)
(2.36) (5.75)
171,0
(6.73)
Mounting Holes
3/8"-16 - 4 Places
40,0
286 (1.57)
(11.26)
35,5 Refer to
(1.40) Model Code
128,3
(5.05)
0,4 6 0,4 6
R05 R05
0,3 0,3
R10 R10
0,2 3 0,2 3
R20 R20
0,1 0,1
0 0
0 25 50 75 100 125 150 0 50 100 150 200 250 300
Flow Rate - L/min Flow Rate - L/min
1,0 15 5,0 73
50 PSID Valve 65
0,8 4,0
9 3,0 45 44
0,6
0,4 2,0 25 PSID Valve
0,2 3 1,0 15
Sample P Calculation : HS221SD32NB2RO5 - Filter assembly having '2' length filter element with micron rating code
'05' at 250 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.3 x 0.8/0.9 + 0.37 x 46/32 x 0.8/0.9
= 0.260 + 0.47
= 0.73 bar
General Data
Pressure filters are used to protect downstream In some applications, pressure filters are used as
components from contamination levels beyond the isolation filters to protect specific components such
recommended cleanliness target. Because they are as proportional or servo valves. Typically these
typically sized for the output of the pump, pressure filters filters are non-bypass and employ elements that are
tend to be smaller than return line filters when cylinders capable of withstanding full system differential
are present. In systems using accumulators, pressure pressure without collapsing. While these filters are
filters must be sized according to the large effective flow sized to handle only a specific components' required
rates present during parts of the duty cycle. flow, the use of high collapse elements result in a
higher cost than elements used in housings with
bypass valves. Most isolation filters are direct-
mounted beneath the valve which can save space
as well as reduce plumbing costs.
Applications
Paper Mills Test and simulation
Steel Mills equipment
Injection molding Entertainment stage
machines equipment
Motion bases Hydrostatic drives
Sawmill equipment Power generation
turbine control systems
Flight simulators
ECF 1 SB 1 J 3 * V ***
1 2 3 4 5 6 7 8 9
Housing Dimensions
mm (inch)
48.9
(1.929)
Spotface
35.5
(1.399) 1.5
HEX
1 5/16-12UN-2B IN.
SAE-16 PORT
19.05
19.05 0.76 3.3 (0.75)
(0.75) (0.03) (0.13)
Min. Full Thread
(3.157) (2.634)
20
25.3
(.998)
OUTLET
20 20
Pressure drop - psid
Pressure drop-bar
Pressure drop-bar
1,25 1,25
16 16
1,00 1,00
0,75 12 12
0,75
0,50 8 8
0,50
0,25 4 0,25 4
0 0 0 0
0 4 8 12 16 20 24 0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72
Flow Rate - L/min Flow Rate - L/min
Beta Ratio: x(c) = 1000 Rated flow: Length 3 60 L/min (16 USgpm)
to ISO 16889 Length 6 110 L/min (29 USgpm)
Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
Designed to comply with Optional seals available for phosphate esters.
ANSI specifications and
Temp range: -26C to +121C (-15F to +250F)
ISO cleanliness standards
Pressure rating: Operating 100 bar (1500 psi)
Visual, electrical, and Fatigue 100 bar (1500 psi)
electrical indicators with
Material: Head Aluminum
lamp options for system Bowl Aluminum
design flexibility
Dry weight: Length 3 1,5 kg (3.3 lbs)
Poppet type by-pass valve (Approximate) Length 6 1,8 kg (4.0 lbs)
construction
High efficiency
replacement elements in
standard configurations
(C-Pak) to meet Target
Cleanliness Levels
High collapse elements
available for non-bypass
applications
LV2P * SA * ** * * * **
1 2 3 4 5 6 7 8 9
LV2P Series 1 Filter Series - LV2P 5 Indicator Options UL - Electrical 4.9 bar (70 psi),
Filter Assembly Model Hirschmann w 230 volt
AN - Visual 4.9 bar (70 psi),
Code 2 light
Element Collapse Rating No Connector
UH - Electrical 4.9 bar
1 - 17 bar (250 psi) Low LN - Visual 2 bar (30 psi),
(70 psi), Hirschmann
Sample model code: Collapse No Connector
4 - 103 bar (1500 psi) High JN - No Indicator (plug), 6 Seal Material
LV2P1SA4LNB3C05 Collapse No Connector
RB - Electrical 2 bar (30 psi), B- Buna-N
3 Port Options Brad Harrison V- Viton-A
SA - 1.062 - 12UN SAE-12 RJ - Electrical 2 bar (30 psi), 7
Hirschmann w 24 volt Assembly Length
(3/4" tube)
light mm (inch)
4 Valve Options RK - Electrical 2 bar (30 psi), 3 - 187 (7.36)
Hirschmann w 115 volt 6 - 254 (10.0)
1 - Non-Bypass
light
4 - Bypass set at 2.9 bar (43 8 Element Construction
psi) cracking pressure RL - Electrical 2 bar (30 psi),
Hirschmann w 230 volt C - C-Pak (Code 03, 05, 10, 20)
6 - Bypass set at 6 bar (90
light H - H-Pak (Code 03, 05, 10)
psi) cracking pressure
RH - Electrical 2 bar (30 psi), X - no element
Hirschmann
UB - Electrical 4.9 bar 9 Fluid Cleanliness Rating
(70 psi), Brad Harrison Target fluid
UJ - Electrical 4.9 bar Code cleanliness level
(70 psi), Hirschmann 03 16/14/12 or better
w 24 volt light 05 18/16/14 or better
UK - Electrical 4.9 bar
10 20/18/15 or better
(70 psi), Hirschmann
w 115 volt light 20 22/19/16 or better
XX no element
V0513 * * * **
1 2 3 4 5
Housing Dimensions 85
mm (inch) (3.35) 42.5
(1.67)
17.5
3/8-24UNF-2B IN. (0.69)
14 DEEP
4 PL'S
35
(1.38)
50 6
(1.97) (0.24)
Length 3
180
(7.08)
Length 6
242
(9.72)
75
(2.95)
68
( 2.68)
Clearance
Drain Plug G 1/2 Required
(standard for sizes 330 & 660 for Element
optional for sizes 30 - 280) Removal
0,69 10 122.5
8,0 112.5
0,55 8
7,0 102.5
0,41 6
92.5
0,28 4 6,0
82.5
0,14 2 5,0 72.5
0 0 0 10 20 30 40 50 60
0 19 38 57 76 95 114
Flow Rate - L/min Flow Rate - L/min
Sample P Calculation : LV2P1SA4LNB3C05 - Filter assembly having '3' length filter element with micron rating code
'05' at 50 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.20x 0.8/0.9 + 50 x 0.020 x 46/32 x 0.8/0.9
= 0.170 + 1.61
= 1.78 bar
Beta Ratio: x(c) = 1000 Rated flow: Length 5 160 L/min (42 USgpm)
to ISO 16889 Length 7 330 L/min (87 USgpm)
Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
Designed to comply with Optional seals available for phosphate esters.
ANSI specifications and
Temp range: -40C to +121C (-40F to +250F))
ISO cleanliness standards
Pressure rating: Operating 100 bar (1500 psi)
Visual, electrical, and Fatigue 100 bar (1500 psi)
electrical indicators with
Material: Head Aluminum
lamp options for system Bowl Aluminum
design flexibility
Dry weight: Length 5 3,7 kg (8.2 lbs)
High efficiency (Approximate) Length 7 8,0 kg (17.6 lbs)
replacement elements in
standard configurations
(C-Pak) to meet Target
Cleanliness Levels
Poppet type by-pass valve
construction
High collapse elements
available for non-bypass
applications
LV4P * S* * ** * * * **
1 2 3 4 5 6 7 8 9
LV4P Series 1 Filter Series - LV4P 5 Indicator Options UL - Electrical 4.9 bar (70 psi),
Filter Assembly Hirschmann w 230 volt
AN - Visual 4.9 bar (70 psi),
Model Code 2 light
Element Collapse Rating No Connector
UH - Electrical 4.9 bar
1 - 17 bar (250 psi) LN - Visual 2 bar (30 psi),
(70 psi), Hirschmann
Sample model code: Low Collapse No Connector
LV4P1SC4LNB5C05 4 - 103 bar (1500 psi) JN - No Indicator (plug), 6 Seal Material
High Collapse No Connector
RB - Electrical 2 bar (30 psi), B - Buna-N
3 Port Options Brad Harrison V - Viton-A
Length 5: RJ - Electrical 2 bar (30 psi), 7
Hirshmann w 24 volt Assembly Length
SC - 1.625 - 12UN SAE-20
light mm (inch)
Str. thd. (11/4" tube)
RK - Electrical 2 bar (30 psi), 5 - 247 (9.73)
Length 7:
Hirschmann w 115 volt 7 - 312 (12.29)
SD - 1.875 - 12UN SAE-24
Str. thd. (11/2" tube) light
8 Element Construction
RL - Electrical 2 bar (30 psi),
4 Valve Options Hirschmann w 230 volt C - C-Pak (code 03, 05, 10,
light 20)
1 - Non-Bypass
RH - Electrical 2 bar (30 psi), H - H-Pak (code 03, 05, 10)
4 - Bypass set at 2.9 bar (43
Hirschmann X - no element
psi) cracking pressure
6 - Bypass set at 6 bar (90 UB - Electrical 2 bar (70 psi),
Brad Harrison 9 Fluid Cleanliness Rating
psi) cracking pressure
UJ - Electrical 4.9 bar Target fluid
(70 psi), Hirschmann Code cleanliness level
w 24 volt light 03 16/14/12 or better
UK - Electrical 4.9 bar
(70psi), Hirschmann 05 18/16/14 or better
w 115 volt light 10 20/18/15 or better
20 22/19/16 or better
V0513 * * * **
1 2 3 4 5
Housing Dimensions 85
mm (inch) (3.35) 42.5
(1.67)
17.5
3/8-24UNF-2B IN. (0.69)
14 DEEP
4 PL'S
35
(1.38)
Length 5
65 6
(2.56) (0.24)
Length 7
85
(3.35)
Length 5
240
(9.45)
Length 7
313
(12.32)
Length 5
95
(3.74)
Length 7
105
Length 5 Length 7 (4.13)
95 130
( 3.74) ( 5.12)
Clearance
Drain Plug G 1/2 Required
(standard for sizes 330 & 660 for Element
optional for sizes 30 - 280) Removal
Sample P Calculation : LV4P1SC4LNB5C05 - Filter assembly having '5' length filter element with micron rating code
'05' at 100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.10 x 0.8/0.9 + 100 x 0.009 x 46/32 x 0.8/0.9
= 0.088 + 1.143
= 1.23 bar
EATON Vickers Filtration Catalog E-FIFI-MC002-E2 December 2007 115
Pressure Filters Flows to 90 L/min (24 USgpm)
Pressures to 280 bar (4,000 psi)
HF2P Series
Beta Ratio: x(c) = 1000 Rated flow: Length 1 45 L/min (12 USgpm)
to ISO 16889 Length 2 91 L/min (24 USgpm)
Designed to comply with Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water and
ANSI specifications and water-in-oil fluids. Optional seals available for phosphate esters.
ISO cleanliness standards Temp range: -26C to +121C (-15F to +250F)
Visual, electrical, and Pressure rating: Operating 280 bar (4000 psi)
electrical indicators with Fatigue 280 bar (4000 psi)
lamp options for system Material: Head Ductile iron
design flexibility Bowl Carbon Steel
Conforms to HF2 Dry weight: Length 1 4,6 kg (10.1lbs)
(Approximate) Length 2 5,9 kg (134lbs)
automotive specifications
Compact design for use with
servo and proportional valves
Manifold mounting option
for system flexibility
High efficiency
replacement elements in
standard configurations
(C-Pak) to meet Target
Cleanliness Levels HF2P * ** * ** * * * **
High collapse elements
available for non-bypass 1 2 3 4 5 6 7 8 9
applications
HF2P Series 1 Filter Series - HF2P RB - Electrical 2 bar (30 psi), UK - Electrical 4.9 bar
Filter and Element Brad Harrison (70 psi), Hirschmann
RH - Electrical 2 bar (30 psi), w 115 volt light
Model Code 2 Element Collapse Rating Hirschmann UL - Electrical 4.9 bar (70 psi),
1 - 17 bar (250 psi) Low RJ - Electrical 2 bar (30 psi), Hirschmann w 230 volt
Sample model code: Collapse Hirschmann w 24 volt light
4 - 207 bar (3000 psi) High light
HF2P1SA4LNB2C05 Collapse RK - Electrical 2 bar (30 psi), 6 Seal Material
NOTE: Use 1 only with bypass valve or Hirschmann w 115 volt
monitored P indicator. B - Buna-N
light V - Viton-A
RL - Electrical 2 bar (30 psi),
3 Port Options Hirschmann w 230 volt 7 Assembly Length
BA - G3/4 to ISO 228 light
SA - 1.062 - 12UN SAE-12 TB - Electrical 7.9 bar mm (inch)
(3/4" tube) (115 psi), Brad Harrison 1 - 211.9 (8.3)
WS - Subplate mounting TH - Electrical 7.9 bar 2 - 304.9 (12.0)
(115 psi), Hirschmann
8 Element Construction
4 Valve Options TJ - Electrical 7.9 bar
(115 psi), Hirschmann C - 17 bar (250 psi)
1 - Non-Bypass
w 24 volt light Low Collapse
4 - Bypass set at 2.9 bar TK - Electrical 7.9 bar
(43 psi) cracking pressure H - 207 bar (3000 psi)
(115 psi), Hirschmann High Collapse
6 - Bypass set at 6 bar w 115 volt light
(90 psi) cracking pressure X - no element
TL - Electrical 7.9 bar (115
psi), 9 Fluid Cleanliness Rating
5 Indicator Options Hirschmann w 230 volt
Target fluid
AN - Visual 4.9 bar (70 psi), light Code cleanliness level
No Connector UB - Electrical 4.9 bar
JN - No Indicator (plug), (70 psi), Brad Harrison 03 16/14/12 or better
No Connector UH - Electrical 4.9 bar 05 18/16/14 or better
LN - Visual 2 bar (30 psi), (70 psi), Hirschmann 10 20/18/15 or better
No Connector UJ - Electrical 4.9 bar
20 22/19/16 or better
ON - Visual 7.9 bar (115 psi), (70 psi), Hirschmann
w 24 volt light XX no element
No Connector
1 2 3 4 5 6
Housing Dimensions
mm (inch)
88.9
Subplate Mounting Outlet (3.50) Inlet Indicator Plug 21.4
7 44.5
(0.28) (1.75) (.08)
15.9
25.4 (0.63)
(1.00) 52 86
80 (2.05) (3.39)
(3.15)
17.5 31.8
(0.69) (1.25)
31.8 17 104
8.6 (0.34) thru (1.25) (0.67) (4.09)
4PL's
5/16-18UNC x 4.25 long
grade 8 bolts for 0.5
engagement are recommended
(4 req'd). Torque 9-12lb-ft (12-16Nm)
27 HEX 79.4
(1.06) (3.13)
7 24.2
(0.95) Inlet Outlet
(0.28)
6.75
(0.27)
96 98
(3.78) (3.86)
Refer to
Model Code
24 HEX
(0.95)
75 (2.96)
76.2 Clearance for
(3.00) Element Removal
Note: For flow in gpm, use the values inside the brackets.
Note: The values for bar/lpm have been rounded to the third decimal.
Pressure drop-bar
0,8 272.5
15,0 222.5
172.5
0,4 6
10,0
122.5
0 5,0 72.5
0 20 40 60 80 100 0 10 20 30 40 50 60 70 80
Flow Rate - L/min Flow Rate - L/min
Sample P Calculation : HF2P1SA4LNB2C05 - Filter assembly having '2' length filter element with micron rating
code '05' at 50 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.26 x 0.8/0.9 + 50 x 0.016 x 46/32 x 0.8/0.9
= 0.220 + 1.01
= 1.23 bar
Beta Ratio: x(c) = 1000 Rated flow: Length 5 68 L/min (18 USgpm)
to ISO 16889 Length 7 113.5 L/min (30 USgpm)
Designed to comply with Fluid compatibility: Compatible with most petroleum oil, oil-in-water and water-in-oil fluids.
ANSI specifications and Optional seals available for phosphate esters.
ISO cleanliness standards Temp range: -26C to +121C (-15F to +250F)
Visual, electrical, and Pressure rating: Operating 276 bar (4000 psi)
electrical indicators with Fatigue 276 bar (4000 psi)
lamp options for system Material: Head Ductile iron
design flexibility Bowl Steel
High efficiency Dry weight: Length 5 3,9 kg (8.3 lbs)
(Approximate) Length 7 4,5 kg (9.9 lbs)
replacement elements in
standard configurations
(C-Pak) to meet Target
Cleanliness Levels
Poppet type leak by-pass
valve construction
MF2P 1 SA 5 ** * * * **
1 2 3 4 5 6 7 8 9
V0512 * * C **
1 2 3 4 5
Housing Dimensions 41
92 (1.61)
mm (inch) 6
(3.62) Clogging
(0.24) Indicator
1 1/16-12 UN
Port
35 35
(1.38) (1.38)
90
(3.54)
Length 5
204
(8.03)
Length 7
257
(10.12)
SW 27
55 76,2
(2.17) (3.00)
55 86
(3.39)
OUTLET R9
INLET
45 40
(1.37) (1.57)
mounting threads
3/8-16 UNC
Housing Bypass
Flow Rate - USgpm Flow Rate - USgpm
0 5 10 15 20 25 30 0 2 4 6 8 10 12 14
16 20,0
1,0 272.5
247.5
0,6 12 15,0 222.5
10 197.5
0,5
8 172.5
0,4 6 10,0 147.5
4 122.5
0,2 97.5
2
0,0 0 5,0 72.5
0 15 30 45 60 75 90 105 0 10 20 30 40 50 60
Flow Rate - L/min Flow Rate - L/min
Sample P Calculation : MF2P1SA5UNB5C05 - Filter assembly having '5' length filter element with micron rating
code '05' at 50 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.3 x 0.8/0.9 + 50 x 0.011 x 46/32 x 0.8/0.9
= 0.260 + 0.69
= 0.95 bar
1 2 3 4 5 6 7 8
***** * * H **
1 2 3 4 5
D03 Pattern
P
Indicator Port
G 1/2 1.81
A B (46mm)
8.90 1.77
(226mm) (45mm)
Clearance Required
for Element Removal
D05 Pattern
T T
0 0 0
0 5 10 15 20 25 0 10 20 30 40 0 10 20 30 40 50 60 70
Flow Rate - L/min Flow Rate - L/min Flow Rate - L/min
Sample P Calculation : OFPH031SAATNBHC05 - Filter assembly having '3' length filter element with micron rating
code '05' at 20 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 1.6 x 0.8/0.9 + 20 x 0.067 x 46/32 x 0.8/0.9
= 1.400 + 1.7
= 3.1 bar
Beta Ratio: x(c) = 1000 Rated flow: Length 3 189 L/min (50 USgpm)
to ISO 16889 Length 6 379 L/min (100 USgpm)
Length 7 568 L/min (150 USgpm)
Designed to comply with Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water and
ANSI specifications and water-in-oil fluids. Optional seals available for phosphate esters.
ISO cleanliness standards Temp range: -26C to +121C (-15F to +250F)
Visual and electrical Pressure rating: Operating 345 bar (5000 psi)
indicators with lamp Fatigue 345 bar (5000 psi)
options for system Material: Head Ductile Iron
design flexibility Bowl Carbon Steel
Conforms to HF4 Lid Ductile Iron
specifications Dry weight: Length 3 28,8 kg (63.4 lbs)
(Approximate) Length 6 38,7 kg (85.3 lbs)
Fatigue rated to 5000 psi Length 7 51,5 kg (113.6 lbs)
for maximum reliability in
rugged applications
Top loading design to
ease maintenance and
minimize spillage
Multiple filter element HF4P * ** * ** * * * **
lengths for design flexibility
High efficiency 1 2 3 4 5 6 7 8 9
replacement elements in JN - No Indicator (plug), UL - Electrical 4.9 bar (70 psi),
1 Filter Series - HF4P
standard configurations No Connector Hirschmann w 230 volt
(C-Pak) to meet Target RB - Electrical 2 bar (30 psi), light
2 Element Collapse Rating
Cleanliness Levels Brad Harrison UH - Electrical 4.9 bar
1 - 10 bar (150 psi) Low RJ - Electrical 2 bar (30 psi), (70 psi), Hirschmann
High collapse elements
Collapse Hirschmann w 24 volt
available for non-bypass 4 - 207 bar (3000 psi) light 6 Seal material
applications High Collapse RK - Electrical 2 bar (30 psi), B - Buna-N
Series 3
Hirschmann w 115 volt V - Viton-A
Port options light
Filter and Element
BD - G11/2 to ISO 228 RL - Electrical 2 bar (30 psi), 7 Assembly Length
Model Code ME - 11/2" SAE 4 bolt Flange Hirschmann w 230 volt mm (inch)
Code 61 (M12 x 1.75) light 3 - 447 (17.6)
Sample model code: MR - 11/2" SAE 4 bolt Flange RH - Electrical 2 bar (30 psi), 6 - 685.3 (27)
HF4P1SD4LNB6C05 Code 62 (M16 x 2.0) Hirschmann 7 - 923.5 (36.4)
SD - 1.875 - 12 UN SAE-24 TB - Electrical 7.9 bar
str. Thd. (11/2" tube) (115 psi), Brad Harrison 8 Element construction
FE - 11/2" SAE 4 bolt Flange TJ - Electrical 7.9 bar
Code 61 (UNC) C - 10 bar (150 psi)
(115 psi), Hirschmann
FR - 11/2" SAE 4 bolt Flange Low Collapse
w/ 24 volt light
Code 62 (UNC) H - 207 bar (3000 psi)
TK - Electrical 7.9 bar High Collapse
WS - Subplate mounting (115 psi), Hirschmann
X - no element
w/ 115 volt light
4 Valve options TL - Electrical 7.9 bar 9 Fluid cleanliness rating
1 - Non-Bypass (115 psi), Hirschmann
Target fluid
4 - Bypass set at 2.9 bar w/ 230 volt light Code cleanliness level
(43 psi) cracking pressure TH - Electrical 7.9 bar
6 - Bypass set at 6 bar (115 psi), Hirschmann 03 16/14/12 or better
(90 psi) cracking pressure UB - Electrical 4.9 bar 05 18/16/14 or better
(70 psi), Brad Harrison 10 20/18/15 or better
5 Indicator options UJ - Electrical 4.9 bar 20* 22/19/16 or better
AN - Visual 4.9 bar (70 psi), (70 psi), Hirschmann XX no element
No Connector w 24 volt light
* C-Pak only
LN - Visual 2 bar (30 psi), UK - Electrical 4.9 bar
No Connector (70 psi), Hirschmann
w 115 volt light
1 2 3 4 5 6
V405 Element 1 Filter Element - V405 4 Element Length 6 Fluid Cleanliness Rating
model code mm (inch) Target fluid
2 Element Collapse Rating 3 - 229 (9) Code cleanliness level
(Meets HF4 Standard)
1 - 10 bar (150 psi) 6 - 457 (18) 03 16/14/12
4 - 206.9 bar (3000 psi) 7 - 686 (27) 05 18/16/14
Sample model code:
High Collapse 10 20/18/15
V4051B3C03 NOTE: Use 1 only with bypass valve or 5 Element Construction
monitored delta P indicator. 20 22/19/16
C - C-Pak (code 03, 05, 10,
3 20)
Seals H - H-Pak (code 03, 05, 10)
B - Buna-N
V - Viton-A
Housing Dimensions Drain Plug
25.4 (1.00) 50.8
mm (inch) Hex 14.2 (2.00)
(0.56) 7.9 Outlet
thru (0.31)
57.2
158.8 4 PL'S (2.25)
(6.25)
79.4
(3.13) 114.3
(4.50)
Vent Plug
73 Inlet
(2.88) 146.1 Refer to
(5.75) Model Code Indicator
63.5 Port
(2.50)
127
(5.00)
133.4
22.4 (5.25) View X - Subplate Mounting
(0.88) 66.7
(2.63)
Refer to
Model
Code
70
(2.76)
35.1
Bolt Thread (1.38)
View X
E D C
A B C D E
mm mm mm mm mm
(inch) (inch) (inch) (inch) (inch)
B
A ME 69.8 37.9 35.7 17.9 35.1
(2.75) (1.375) (1.406) (.703) (1.38)
MR 79.3 39.4 36.5 18.2 35.1
(3.125) (1.56) (1.437) (.718) (1.38)
FE 69.8 37.9 35.7 17.9 35.1
(2.75) (1.375) (1.406) (.703) (1.38)
FR 79.3 39.4 36.5 18.2 35.1
(3.125) (1.56) (1.437) (.718) (1.38)
0,75
137
9,0
127
0,50 7
8,0 117
107
0,25 7,0
97
0 6,0 87
0 100 200 300 400
0 50 100 150 200 250 300 350
Flow Rate - L/min Flow Rate - L/min
Sample P Calculation : HF4P1SD4LNB6C05 - Filter assembly having '6' length filter element with micron rating
code '05' at 200 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.26 x 0.8/0.9 + 200 x 0.001 x 46/32 x 0.8/0.9
= 0.220 + 0.25
= 0.47 bar
1 2 3 4 5 6
1
/2-20UNF-2B in. X 17 (0.67)deep 4 Places
8.4 Indicator Plug
(0.33)
52 SAE-16, 24, G1 OR G1 1/2
(2.05)
16" Housing
Refer to
Model Code
117
(4.61)
152
(5.98)
427 Clearance required
Drain Plug G 1/2 130.2 (16.8) for element removal
95 (3.74) (5.13)
Clearance required for element removal
10,0
Pressure drop - bar
1,5
137
9,0
127
1,0 15
8,0 117
107
0,5 7,0
97
0 6,0 87
0 200 400 600 800 0 50 100 150 200 250 300 350
Flow Rate - L/min Flow Rate - L/min
Sample P Calculation : HF3P1SB4LNB2C05 - Filter assembly having '2' length filter element with micron rating code
'05' at 100 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.12 x 0.8/0.9 + 100 x 0.001 x 46/32 x 0.8/0.9
= 0.100 + 0.127
= 0.22 bar
Beta Ratio: x(c) = 1000 Rated flow: Length 2 265 L/min (70 USgpm)
to ISO 16889 Length 4 454 L/min (120 USgpm)
Length 5 565 L/min (150 USgpm)
Designed to comply with Fluid compatibility: Compatible with most petroleum oil, water glycol, oil-in-water and
ANSI specifications and water-in-oil fluids. Optional seals available for phosphate esters.
ISO cleanliness standards Temp range: -26C to +121C (-15F to +250F)
Visual, and electrical Pressure rating: Operating 310 bar (4500 psi)
indicators with lamp Fatigue 410 bar (6000 psi)
options for system design Material: Head Ductile iron
flexibility Bowl Carbon Steel
Conforms to HF3 Dry weight: Length 2 21,8 kg (48.0 lbs)
automotive specifications (Approximate) Length 4 28,5 kg (62.8 lbs)
Length 5 41,4 kg (91.3 lbs)
Fatigue rated to 6000 psi
for maximum reliability in
rugged applications
Side manifold mounting
for ease of maintenance
in many applications
Multiple filter element
lengths for design flexibility
HF3PS * WS * ** * * * **
High efficiency
replacement elements in
standard configurations 1 2 3 4 5 6 7 8 9
(C-Pak) to meet Target
Cleanliness Levels 1 Filter Series - HF3PS RH - Electrical 2 bar (30 psi), UK - Electrical 4.9 bar
Hirschmann (70 psi), Hirschmann
High collapse elements RJ - Electrical 2 bar (30 psi), w 115 volt light
2 Element Collapse Rating
available for non-bypass Hirschmann w 24 volt UL - Electrical 4.9 bar (70 psi),
applications 1 - 17 bar 17 bar (250 psi) light Hirschmann w 230 volt
Low Collapse RK - Electrical 2 bar (30 psi), light
4 - 207 bar (3,000 psi) High Hirschmann w 115 volt
HF3PS Series Collapse 6
light Seal Material
Filter and Element RL - Electrical 2 bar (30 psi),
3 B - Buna-N
Model Code Port Options Hirschmann w 230 volt V - Viton-A
WS - Subplate mounting light
Sample model code: TB - Electrical 7.9 bar 7 Assembly Length
4 Valve Options (115 psi), Brad Harrison mm (inch)
HF3PS1WS4LNB5C05 1 - Non-Bypass TH - Electrical 7.9 bar 2 - 340 (13.3)
4 - Bypass set at 2.9 bar (115 psi), Hirschmann 4 - 461 (18.1)
(43 psi) cracking pressure TJ - Electrical 7.9 bar 5 - 614 (24.2)
6 - Bypass set at 6 bar (115 psi), Hirschmann
(90 psi) cracking pressure w 24 volt light 8 Element Construction
TK - Electrical 7.9 bar
5 C - 17 bar (250 psi)
Indicator Options (115 psi), Hirshmann
Low Collapse
AN - Visual 4.9 bar (70 psi), w 115 volt light
H - 207 bar (3000 psi)
No Connector TL - Electrical 7.9 bar (115
High Collapse
JN - No Indicator (plug), psi),
X - no element
No Connector Hirschmann w 230 volt
KN - Visual 1 bar (15 psi), light 9 Fluid Cleanliness Rating
No Connector UB - Electrical 4.9 bar
Target fluid
LN - Visual 2 bar (30 psi), (70 psi), Brad Harrison Code cleanliness level
No Connector UH - Electrical 4.9 bar
(70 psi), Hirschmann 03 16/14/12 or better
ON - Visual 7.9 bar (115 psi),
No Connector UJ - Electrical 4.9 bar 05 18/16/14 or better
RB - Electrical 2 bar (30 psi), (70 psi), Hirschmann 10 20/18/15 or better
Brad Harrison w 24 volt light 20 22/19/16 or better
XX no element
V602 * * * * **
1 2 3 4 5 6
Housing Dimensions
156.5
mm (inch) (6.16)
79.5
29 (3.13) Indicator Plug
(1.14)
23 (0.91)
Thru 4 PL's
7/8-9UNC X 2.50 long
Grade 8 bolts for 140 193
(5.51) 30 (1.18) (7.6)
1.20 long engagement 2 PL'S
are recommended 95
(3.74) 46.5 C'BORE
(4 Req'd) For 40 X 3.5 O-Ring
Torque 185-200 lb-ft flow port dia. Inlet
(250-270 N-m) 6.1
(0.24)
52
110 (2.05)
(4.33) 60
(2.36)
196
(7.72) 112
(4.41) 130.2
L (5.13)
Outlet
117
(4.61)
36 Hex
(1.42)
115 (4.5) Drain Plug G 1/2 152
Clearance for (5.98) 427 (16.8)
element removal Clearance required for
16" HOUSING element removal
12,0
1,2 17
10,0 145
0,9 8,0
6,0 87
0,6 9
4,0
0,3 2,0
0 0
0 100 200 300 400 500 0 100 200 300 400
Flow Rate - L/min Flow Rate - L/min
Sample P Calculation : HF3PS1WS4LNB5C05 - Filter assembly having '5' length filter element with micron rating
code '05' at 200 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity
(sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing factor from graph + Flow Rate (Lpm) x Element 'K' factor
x sp.gr.(actual)/0.9 (bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.28 x 0.8/0.9 + 200 x 0.002 x 46/32 x 0.8/0.9
= 0.250 + 0.51
= 0.76 bar
DMP * *** ** * ** * * **
1 2 3 4 5 6 7 8 9
VDP *** * * **
1 2 3 4 5
Element model code 1 Filter Element 3 Seal Material 5 Fluid Cleanliness Rating
VDP - DIN Standard Element B - Buna-N Target fluid
Sample model code: V - Viton-A Code cleanliness level
2 Nominal Size 03 16/14/12 or better
VDP160BC06 4
040 - 40 L/min (10.6 USgpm) Element Construction 06 18/16/14 or better
063 - 63 L/min (16.6 USgpm) C - Standard Construction 10 20/18/15 or better
100 - 100 L/min (26.4 USgpm) H - High Collapse 25 22/19/16 or better
B1
Dimensions in mm B2
45
15
40
Port Size
See Chart
h2
h1
68
Remove Elemant
Drain Plug
H3 Minimum
M-6
56
83
50
Outlet Inlet
32
0.6
0.5
p [bar]
0.4
TYPE PORT SIZE B1 B2 H1 H2 H3
0.1
0 10 20 30 40 50 60 70 80 90 100
Flow rate [l/min]
2.0 6m
p [bar]
1.5
10m
1.0 25m
0.5
0.0
0 50 100 150 200 250 300
flow rate [l/min]
p [bar]
1.2 1.2
1.0 1.0
0.8 0.8 6 m
10 m
0.6 0.6
25 m 10 m
0.4 0.4 25 m
0.2 0.2
0.0 0.0
0 15 30 45 60 75 0 15 30 45 60 75
flow rate [l/min] flow rate [l/min]
DHP * *** ** * ** * * **
1 2 3 4 5 6 7 8 9
B1
B2
45
12
40
D1
Port Size
See Chart
h2
h1
65
85 Minimum Clearance to
Drain Plug
Remove Element
M-6
56
89
156
Outlet Inlet
32
H1
116
105 Minimum Clearance to
Drain Plug
Remove Element
M12
11 5
11 3
15 7
Inlet
Outlet
60
p [bar]
0.4
TYPE PORT SIZE B1 B2 D1 H1 H2
DHP 063 G 3/4 150 146 215
0.3
DHP 100 G1 96 50 236 305
0.2
0.1
0 10 20 30 40 50 60 70 80 90 100
Flow rate [l/min]
0.05
0.00
0 40 80 120 160 200 240
Flow rate [l/min]
1
Filter Element 3 Seal Material 5 Media Grade
VDP - DIN Standard Element B - Buna-N 03 16/14/12 or better
Sample model code: V - Viton-A 06 18/16/14 or better
2 Nominal Size Viton is a registered trademark of E.I. DuPont 10 20/18/15 or better
VDP063BC06
063 - 63L/min (16.6USgpm) 25 22/19/16 or better
4 Element Construction
100 - 100L/min (26.4USgpm)
250 - 250L/min (66.0USgpm) C - Standard Construction
400 - 400L/min (105.7USgpm) H - High Collapse Construction
VDP Series
2
Element size 063 Low Collapse 2.5 Element size 063 High Collapse
Element Flow Data 1.8 3m
1.6 2
Flow versus pressure drop: 32 cSt
oil with specific gravity of 0.9
1.4
p [bar]
p [bar]
1.2 1.5
3m 6m
1
(See page 6 for viscosity 0.8 6m 1 10m
corrections for pressure drop.) 0.6 25 m
0.4 10m 0.5
0.2 25 m
0 0 15 30 45 60 75
0 3015 45 60 75
3 Element size 400 Low Collapse flow rate [l/min] flow rate [l/min]
Element size 100 Low Collapse Element size 100 High Collapse
2.5 2.5 3m 4
3m
3m 3.5
p [bar]
2 2
3
p [bar]
p [bar]
1.5 6 m 1.5 2.5
6m 6m
1 10m 2
25m 1 1.5 10m
0.5 10m
25 m 1 25m
0.5
0 0.5
0 50 100 150 200 250 300 350 400 450 500
flow rate [l/min] 0 0
0
20 40 60 80 100 120 140 160 180 200 020 40 60 80 100 120 140 160 180 200
flow rate [l/min] flow rate [l/min]
Element size 250 Low Collapse Element size 250 High Collapse
3 Element size 400 High Collapse 3 3
2.5 2.5 3m
2.5 3m
3m
p [bar]
p [bar]
2 2
p [bar]
2
6m
1.5 6m 1.5 6m 1.5 10m
10m 1 10m 1
1 25m 25m
25 m 0.5 0.5
0.5
0 0
0 0 50 100 150 200 250 300 350 400 450 500 0 50 100 150 200 250 300 350 400 450 500
0 50 100 150 200 250 300 350 400 450 500 flow rate [l/min] flow rate [l/min]
flow rate [l/min]
Sample P Calculation : DHP1100BC4ANBC06 - Filter assembly having filter element with micron rating code '06' at
70 L/min flow rate using a hydraulic fluid at 46 cSt viscosity & specific gravity (sp.gr.)0.8.
P Assembly = P Housing + P Element
= Housing P from graph + Element P valve from from
x sp.gr.(actual)/0.9 graph(bar/lpm) x [ actual cSt / 32 ]
x [Sp.Gr(actual) / 0.9]
= 0.35 x 0.8/0.9 + 0.4 x 46/32 x 0.8/0.9
= 0.310 + 0.51
= 0.82 bar
General Data
Off-line filtration systems (also referred to as a kidney is optimized, heat exchangers can be used within the
loops or recirculation loops) are typically found in off-line system to achieve the necessary operating
variable volume pump systems where system filters parameters. The off-line system can also be used as
do not see continuous flow or where the return flow the make-up point to add fluid to the system and
volume makes a return filter impractical. These help ensure that only clean fluid is introduced to
systems typically consist of a separate pump and filter the system. The off-line system can also be shut-
plumbed to the reservoir along with associated down
components to provide a continuous recirculating flow to change filter elements without securing the main
of fluid from the reservoir through the filter and back system.
to the reservoir.
Rarely can an off-line filtration system be used as the
There are many advantages to incorporating an off- sole contamination control solution. It is normally
line filtration package. Because the system is at a low used to supplement the main system filters and a
pressure and the flow is continuous with little or no typical recommended size for the off-line system flow
flow surges, economical low pressure filter housings rate is approximately 20% of the total main system
can be used. In addition, because temperature control volume.
is necessary to ensure that the components see the
In addition to hydraulic systems, off-line filtration
proper viscosity and that the oxidation rate of the fluid
systems can be used on gearbox applications to clean
the fluid where there are no other lubrication circulation
systems present.
Applications
Pulp and paper mill
equipment
Large central hydraulic
power units
Injection molding
equipment
Stamping presses
Extrusion machines
Incorporates a highly
efficient spin-on filter
element
Relief valve housing
Static pressure gauge
clogging indicator
Element easily replaced TECHNICAL DATA
with stap wrench Fluid Compatibility: Petroleum based oils
Nominal Flow: 4 GPM/ 15 l/min
Applications Maximum Oil Temperature: 80C (180F)
The portable filtration unit Viscosity Range: 40 to 2300 SUS 5-500 mm2/sec
is a compact filter/pump
Max. Operating Pressure: 50 psi/3.5 bar
device used for
transferring and filtering Weight: 27.5 lb/12.5 kg
hydraulic fluids Electrical Motor: 110 VAC (0.25 HP/0.18 KW)
Removing water from oil Dimensions: Length 3660mm (14.41")
Width 3650mm (14.37")
Changing oil in hydraulic
Height 3650mm (14.37")
systems
Note: V0211B1 series Elements ordered separately.
Filling hydraulic systems See OFRS60 Catalog pages for more information on V0211B1 series elements.
with filtered oil
Off-line filtration of
hydraulic systems with
inadequate filtering
capacity
1 2 3 4 5 6
INDICATOR OPTIONS (3,000 PSI - USE WITH FILTER MODELS HV6R, HV3R)
** ** V * ***
1 2 3 4 5
INDICATOR OPTIONS (3000 PSI - USE WITH FILTER MODELS HV6R, HV3R)
Filter Assembly
Description Model Code Letters
POPUP VISUAL 15 psi PV 1B VN KN
POPUP VISUAL 30 psi PV 2B VN LN
POPUP VISUAL 70 psi PV 5B VN AN
BRAD HARRISON 5 PIN ELECTRICAL 15 psi PE 1B V B QB
BRAD HARRISON 5 PIN ELECTRICAL 30 psi PE 2B V B RB
BRAD HARRISON 5 PIN ELECTRICAL 70 psi PE 5B V B UB
HIRSCHMANN ELECTRICAL 15 psi PE 1B V H QH
HIRSCHMANN ELECTRICAL 30 psi PE 2B V H RH
HIRSCHMANN ELECTRICAL 70 psi PE 5B V H UH
HIRSCHMANN VISUAL ELECTRICAL 15 psi - L24 PE 1B V H L24 QJ
HIRSCHMANN VISUAL ELECTRICAL 30 psi - L24 PE 2B V H L24 RJ
HIRSCHMANN VISUAL ELECTRICAL 70 psi - L24 PE 5B V H L24 UJ
HIRSCHMANN VISUAL ELECTRICAL 15 psi - L115 PE 1B V H L115 QK
HIRSCHMANN VISUAL ELECTRICAL 30 psi - L115 PE 2B V H L115 RK
HIRSCHMANN VISUAL ELECTRICAL 70 psi - L115 PE 5B V H L115 UK
HIRSCHMANN VISUAL ELECTRICAL 15 psi - L230 PE 1B V H L230 QL
HIRSCHMANN VISUAL ELECTRICAL 30 psi - L230 PE 2B V H L230 RL
HIRSCHMANN VISUAL ELECTRICAL 70 psi - L230 PE 5B V H L230 UL
PE * B V B PV * B VN
PHE * B V B
58 27
(2.28) (1.06)
A WHITE 1
3 RED
GREEN 2
P
1
2 ORANGE 34
27 HEX
BLACK 5
63.5 (1.06)
(2.50)
B
62.5 29
(2.46) 100.6 Schematic
(1.14)
(3.96)
G 1/2
27 G 1/2
(1.06)
PE * B V H PE * B V H L * *
PHE * B V H PHE * B V H L * *
70
(2.76)
51 A )
(2.00) 3
A ) 3P )
3 ) 1
3 1 )
P
2 )
1 1 2 )
) B
2 2
B )
60.2 111.4 Schematic
70
(2.76) 108.1 (2.37) (4.39)
(4.26) Schematic
27 G 1/2
27 G 1/2 (1.06)
(1.06)
PLV 2B V H L24
1 2 3 4 5
77
(3.03)
75
(2.95)
105.8
(4.16)
30 1/8 BSP
(1.18)
3
2
0 10
bar
50
30.5
(1.20) 46.7
(1.84)
1/8" BSP
13.97
(0.55)
Switch: SPDT NO
GD GREEN
Rating: 7 amps, resistive C
4 amps, inductive 1 2
TO
2 amps, lamp load NC RED 3 SYSTEM
@28 VDC, 115 VAC 60 Hz
& 220 VAC 50 Hz or 60 Hz
PIN
ARRANGEMENT
NO 1 5
TO
C
SYSTEM
2 4
NC RED
3 GREEN
70
77 (2.76)
(3.03)
75 75
(2.95) (2.95)
105.8 105.8
(4.16) (4.16)
30 1/8 NPT
(1.18) 30 1/8 NPT
(1.18)
HOUSING PART NUMBER 0-4 Bar (0-60 PSI) Gauge 0-10 Bar (0-160 PSI) Gauge
HF4RT 3039703 Gauge 0-160 psi (use with 43 psi Bypass Valve)
3039704 Gauge 0-60 psi (use with 25 psi Bypass Valve)
25
Note: Gauges indicate pressure in both bar and psi 20 3
2
0 PSI60 0 10
bar
50 50
30.5 30.5
(1.20) (1.20)
46.7 46.7
(1.84) (1.84)
14
(0.6) 172
(6.8)
280
(11)
290
(11.4")
D DIMENSIONS
A Housing A B C D E
diameter length
C HL 15, HL 16 7/16- 20 UNF 127,0 181,0 7/16 - 20 UNF x 0.75 12,7
B P-232964-01 thru (4) on 6.25 dia. (5.00) (7.12) Recommended bolts (0.50)
BC equally spaced