Environmental Profile
Solutions
-2-
Confidential & Proprietary
Aspen Turned Aerogels from a Curiosity Into an Industrial Product
Pyrogel 6350 created
Aerogel
for the petrochemical
processing industry
PUF
Aerogels
invented
Aerogels for Aspen makes fiber-
spacesuits reinforced aerogels Aerogels offshore
1930s 1993 1995 1997 1999 2001 2003 2005 2007
From the
30s to Aspen Aerogels born Plant 1
the 80s, opens Plant 2
many opens
large
chemical
companies
tried to
produce
aerogels
10 MM sqft capacity
Step 2:
Extract solvents
with supercritical
carbon dioxide
Step 3:
Resulting dry,
fiber-reinforced
aerogel blanket
-4-
Aerogels 95 - 97% air Features
Features&&Benefits
Benefits
Convection
Conduction
Low mass minimal conduction Radiation
Need to opacify
Confidential & Proprietary
Aerogels Have the Lowest k-Value of Any Industrial Insulation
Temperature (F)
-400 -200 0 200 400 600 800 1000 1200
250
Thermal Conductivity (Btu-in/hr-ft2-F)
1.6
Mineral Wool
0.8 Calsil
100
0.6
Cellular
0.4 glass
50
Cryogel Z PUR/PIR Pyrogel XT
0.2
Spaceloft
0.0 0
-200 -100 0 100 200 300 400 500 600
Temperature (C)
-6-
Confidential & Proprietary
High Performance Thermal Insulation , Feature .
-7-
Confidential & Proprietary
Ageing in the B&C Environment
This offers a constant design performance independent of time or within the realms
of the B&C domain temperature or humidity.
4%
2%
0%
-2%
-4%
-6%
-8%
-10%
0 1 2 3 4 5 6 7 8 9 10 11 12
Accelerated Aging Time (Weeks)
-8-
Confidential & Proprietary
Accelerated Ageing
10 Degree Rule for Arrhenius
Aging:
= t , where :
t a
s
( T a T s ) / 10
2
t = test time (hours)
a
T = test temperature ( K )
a
T = service temperature ( K )
s
-9-
Confidential & Proprietary
Spaceloft X251 Aging
10%
Real time, ambient temperature aging
8% over 52 weeks
6%
No statistical change in thermal
Conductivity Change
4%
2%
conductivity *
0%
-2% Confirms short term model
-4%
prediction
-6%
-8% Additional real time aging data
-10%
- 4 8 12 16 20 24 28 32 36 40 44 48 52
collected as samples age
Real Time Aging (Weeks)
-10-
Confidential & Proprietary
High Performance Thermal Insulation , Benefit.
SpaceTherm
Ultra thin insulation offering same U value as traditional insulation.
Flooring solutions
-11-
Confidential & Proprietary
High Performance Thermal Insulation , Benefit.
SpaceTherm
Spaceloft
8m
Thickness m 0.02
Competitive
Material Spaceloft Gain
Additional Internal
Area m2 2.38 0.62 1.76
Additional Volume m3 5.14 1.33 3.80
Increased Value GBP 308 2,223 10560
This calculation is for estimation purposes only. Aspen Aerogels accepts no liability for these figures
-12-
Confidential & Proprietary
Summary of Contents
Environmental Profile
Solutions
-13-
Confidential & Proprietary
Fire Performance
-14-
Confidential & Proprietary
Breathability & Hydrophobicity
An interesting combination.
This allows for the design of both venting concepts and also installation where
water would be a problem to traditional insulation materials
Hydrophobic
Vapor permeable
-15-
Confidential & Proprietary
Breathability & Hydrophobicity
-16-
Confidential & Proprietary
Breathability & Hydrophobicity
SL 9251 83 cm (mean)
SL 3251 61 cm (mean)
-17-
Compressive
CompressiveStress
StressStrain
StrainCurves.
Curves.
Figure 1. Compressive stress-strain plots for three ply stacks of SL9251 samples from
lot 267 up to 1.03 MPa (150 psi).
Features
Features&&Benefits
Benefits
Acoustics.
0.70 35
Spaceloft* is primarily
35
Absorption Coefficient 20.0 Sound Transmission Class
0.60 30
Thickness 30
Thickness (mm)
a thermal insulator
0.50 25
15.0 25
0.40 20
20
10.0
in certain combinations
0.30 15 15
0.20 10 10
5.0
0.00 0 0.0 0
Mineral Wool
Melamine
Fiberglass
PG 6350
PG 6650
CG 6000
SL 9200C
SL 6250C
PG 4250C
CG 6000C
Melamine
Mineral
Fiberglass
PG 6350
PG 6650
CG 6000
SL 9200C
SL 6250C
PG 4250C
CG 6000C
Wool
Transmission loss Key acoustic performance properties
0.0200
0.0180
0.0160
Material Loss Coeffient (Damping)
Thickness (mm)
30
25
0.0120
20
0.0000 0
SL 9200C
CG 6000C
SL 6250C
PG 4250C
PG 6650
Melamine
CG 6000
PG 6350
Fiberglass
Mineral Wool
confidential & proprietary
-19-
Confidential & Proprietary
Health & Safety
Dust Concerns.
The pore size is +-20 nano-meters , the dust size is measured in Microns
Dust analysis from Aerogel workshop environment , report by Safety Consulting Engineers inc.
-20-
Confidential & Proprietary
Health & Safety
EXECUTIVE SUMMARY
ET-50 Expected In vivo
SAMPLE (hrs) Irritancy
07050160 Spaceloft 6251 > 24.0 Non-Irritating
07050162 Pyrogel 6651 x
Hitox > 24.0 Non-Irritating
07050161 Pyrogel 6350 > 24.0 Non-Irritating
1.0% Triton X-100 8.9 Moderate to Mild
-21-
Confidential & Proprietary
Health & Safety
Environmental Profile
Solutions
-23-
Confidential & Proprietary
Environmental/Sustainability
-24-
Confidential & Proprietary
Embodied Energy & Embodied CO2 of Aerogel blankets
Aerogel
Raw Materials
35.5 MJ/kg
3.24 kg/kg
Gel Composite
Sol Fibrous
Reinforcement
12.1 MJ/kg Manufacturing
0.59 kg/kg 6.3 MJ/kg
0.46 kg/kg
Component Embodied Energy Embodied CO2
MJ/kg kg/kg
Silica precursor and other raw materials 35.5 3.2
Batting (fibrous reinforcement) 12.1 0.6
Aspen Aerogels Production Process 3.5 0.4
CO2 for Supercritical Extraction* 2.1 -
Pollution control equipment 0.7 0.03
Transport from US to Europe** 2.2 0.14
Transport
*CO2 recovered from other external industrial processes 2.2 MJ/kg
**Assumes 6000 km by cargo ship, 500 km by road 0.14 kg/kg
Total: 56 4.4
Spaceloft X251
Embodied
EmbodiedCO2
CO2==5,4
5,4kg
kg//sq
sqmt
-25- mtof
ofSL
SL9251
9251
Confidential & Proprietary
EE & ECO2 Comparison
Thermal EE per Ther. Res. ECO2 per Ther. Res.
Thermal Resistance ECO2 (kg of
Material Conductivity EE (MJ/kg) (EE/R-value per (ECO2/R-value per
(R-value per inch) 1 CO2/kg)
(mW/m-K) 1 inch) inch)
1 1
Spaceloft X251 12 12.0 53.0 4.2 4.42 0.35
2 2
Fiberglass (recycled glass) 40 3.8 28.0 1.4 7.37 0.36
2 2
Fiberglass (virgin glass) 40 3.8 39.2 1.9 10.32 0.50
2 2
Mineral wool 40 3.8 16.6 1.2 4.37 0.32
3 2
Expanded polystyrene 32 4.5 111.6 3.0 24.80 0.67
3 2
Polyisocyanurate 24 6.0 69.8 5.5 11.63 0.92
1
Manufacturer data
2
Inventory of Carbon & Energy, University of Bath, UK
3
Comparison of Energy Evaluation of Plastic Products and Their Alternatives for the Building, Construction, and Transportation Industries - The Society of the Plastics Industry
EE of aerogel is higher than others on a mass basis, but our thermal performance is
superior, such that the energy return/payback is greater.
-26-
Confidential & Proprietary
Environmental Payback in B&C
-27-
Confidential & Proprietary
Spaceloft* B&C Summary
Spaceloft* potentially offers solutions for the application areas presently deemed
Hard To Treat due to space restriction.
Spaceloft* offers an energy & CO2 payback in less than 12 month for typical
B&C applications.
-28-
Confidential & Proprietary
Summary of Contents
Environmental Profile
Solutions
-29-
Confidential & Proprietary
Spaceloft B&C Summary
Roofs/Loft conversions
under tile
Walls internal
external
Floors heated
thin
cold bridges
Terraces
Timber Frame
Metal Frame
-30-
Confidential & Proprietary
Case Study.
-31-
Confidential & Proprietary
Solid wall (9 brickwork)
Spacetherm P
(10mm Space Loft
SL9251 + 9.5mm U value estimation
plasterboard) Structure Thickness U value
mm W/ m2h improvement
Solid Wall 215 2.1
SW + 1 layer Spacetherm 240 0.8 62%
SW + 2 layer Spacetherm 250 0.49 77%
SW + 3 layer Spacetherm 260 0.35 83%
215mm SW + 4 layer Spacetherm 270 0.29 86%
brickwork
60-85 % U value
reduction
-32-
Confidential & Proprietary
Case Study. External Cladding
No thermal bridges
-33-
Confidential & Proprietary
Solid wall (9 brickwork)
13mm of Paraclad
60% reduction in line with Climate Change Bill proposals
equates to upgraded U value of 0.84 W/mK
Wall construction
13mm plaster
Material Thickness Thermal Thermal
(mm) Conductivity Resistance
(W/mK) (m2K/W)
Paraclad
External Surface Ro 0.04
Total R 1.178
U Value 0.739
215mm
brickwork 65% U value
reduction
-34-
Confidential & Proprietary
External Rendering
Fast Installation
Multiple layers
Minimum joints
-35-
Confidential & Proprietary
External Rendering
2 Mechanical Fixation
-37-
Confidential & Proprietary
Internal Render
Creates Space.
-38-
Confidential & Proprietary
Internal Render
-39-
Confidential & Proprietary
Underfloor Heating
Radiant Floor Power Usage
Control Floor
0.18
Spaceloft 3251
r 0.14
u
o
/h 0.12
h
w
K 0.10
-
e
g
a
s
0.08
U
re 0.06
w
o
P 0.04
0.02
0.00
-40-
Confidential & Proprietary
Renovation of basement : Fast & Cost effective installation
-41-
Confidential & Proprietary
Renovation of basement : Fast & Cost effective installation
-42-
Confidential & Proprietary
Thermal Bridging , brick & block
-43-
Confidential & Proprietary
Thermal Bridging : Timber Frame , Spaceloft Insulcap
With
Without
-44-
Confidential & Proprietary
Thermal Bridging : Metal Frame , Spaceloft Insulcap
Timber framed insulated roof to meet Passive House status, 2 layers SL 9251
Site : Mielen , Zurich , high performance thin wall design , 4 layers SL 9251
-47-
Confidential & Proprietary
Spaceloft* B&C Summary
Spaceloft* potentially offers solutions for the application areas presently deemed
Hard To Treat due to space restriction.
Spaceloft* offers an energy & CO2 payback in less than 12 month for typical
B&C applications.
-48-