Spaceloft* Building & Construction

Confidential & Proprietary


Summary of Contents

Introduction to Aspen & Aerogels

Key Product Attributes

Environmental Profile

Solutions

-2-
Confidential & Proprietary
Aspen Turned Aerogels from a Curiosity Into an Industrial Product
Pyrogel 6350 created
Aerogel
for the petrochemical
processing industry

PUF
Aerogels
invented
Aerogels for Aspen makes fiber-
spacesuits reinforced aerogels Aerogels offshore
1930s 1993 1995 1997 1999 2001 2003 2005 2007
From the
30s to Aspen Aerogels born Plant 1
the 80s, opens Plant 2
many opens
large
chemical
companies
tried to
produce
aerogels
10 MM sqft capacity

-3- 100 MM sqft capacity


Confidential & Proprietary
Aerogel Thermal Performance With the Flexibility of a Blanket

Start with a non-woven blanket


Typically polyester, glass,
carbon, or ceramic fiber
Fill that blanket with a wet gel
Dry the blanket via Step 1:
supercritical CO2 extraction Fill fibrous
batting with a
Roll the blanket onto a spool liquid-solid
solution

Step 2:
Extract solvents
with supercritical
carbon dioxide

Step 3:
Resulting dry,
fiber-reinforced
aerogel blanket

-4-
Aerogels 95 - 97% air Features
Features&&Benefits
Benefits

Nano sized porosity Thermal


Thermal
Transport
TransportMechanism
Mechanism
Convoluted matrix Conduction,Convection,Radiation
Conduction,Convection,Radiation

Convection

Limited air movement

Conduction
Low mass minimal conduction Radiation
Need to opacify
Confidential & Proprietary
Aerogels Have the Lowest k-Value of Any Industrial Insulation

Temperature (F)
-400 -200 0 200 400 600 800 1000 1200
250
Thermal Conductivity (Btu-in/hr-ft2-F)

1.6
Mineral Wool

Thermal Conductivity (mW/m-K)


Pipe & Board
1.4 200

1.2 Mineral Wool


Blanket Perlite
150
1.0

0.8 Calsil
100
0.6
Cellular
0.4 glass
50
Cryogel Z PUR/PIR Pyrogel XT
0.2
Spaceloft
0.0 0
-200 -100 0 100 200 300 400 500 600
Temperature (C)

-6-
Confidential & Proprietary
High Performance Thermal Insulation , Feature .

EU certified Thermal conductivity


(FIW , Munchen Test Institute)

13,5mW/m-K at mean wall 20C.

Spaceloft Products have an application


Range from -200C to + 200C

Pyrogel Products have a range from


-200C to + 650C

-7-
Confidential & Proprietary
Ageing in the B&C Environment

Spacelofts thermal insulation is derived from its nanoporous structure.

The performance is passive.

There are no blowing agent or vacuum requirements to deliver this performance.

This offers a constant design performance independent of time or within the realms
of the B&C domain temperature or humidity.

Simulated Service Time (years)


0 5 10 15 20 25 30 35 40 45 50 55 60
10%
8%
6%
Conductivity Change

4%
2%
0%
-2%
-4%
-6%
-8%
-10%
0 1 2 3 4 5 6 7 8 9 10 11 12
Accelerated Aging Time (Weeks)

-8-
Confidential & Proprietary
Accelerated Ageing
10 Degree Rule for Arrhenius
Aging:
= t , where :
t a
s
( T a T s ) / 10
2
t = test time (hours)
a

t = service time (hours)


s

T = test temperature ( K )
a

T = service temperature ( K )
s

Testing Temperature (C)

90C Accelerated Aging

Simulated Service Time (years)


60
50
50 40
30
12 weeks of accelerated aging at 40 20
10
90C simulates 60-years of service 30 0
-10
at 10C 20
10
-
- 1 2 3 4 5 6 7 8 9 10 11 12 13

Accelerated Aging Time (weeks)

-9-
Confidential & Proprietary
Spaceloft X251 Aging

Simulated Service Time (years)


Accelerated aging at 90C over 12
0 5 10 15 20 25 30 35 40 45 50 55 60 weeks simulates 60-years of aging at
10%
8% 10C
6%
Conductivity Change

4% Arrhenius model predicts no change


2%
0% in thermal conductivity*
-2%
-4%
-6%
-8%
-10%
0 1 2 3 4 5 6 7 8 9 10 11 12
Accelerated Aging Time (Weeks)

10%
Real time, ambient temperature aging
8% over 52 weeks

6%
No statistical change in thermal
Conductivity Change

4%
2%
conductivity *
0%
-2% Confirms short term model
-4%
prediction
-6%
-8% Additional real time aging data
-10%
- 4 8 12 16 20 24 28 32 36 40 44 48 52
collected as samples age
Real Time Aging (Weeks)

* Within 2% test capability

-10-
Confidential & Proprietary
High Performance Thermal Insulation , Benefit.

SpaceTherm
Ultra thin insulation offering same U value as traditional insulation.

Interior solutions with minimum


interior space lost.

Exterior systems with


minimum reveal disruption.

Thermal bridging solutions .

Flooring solutions
-11-
Confidential & Proprietary
High Performance Thermal Insulation , Benefit.

SpaceTherm

Ultra thin insulation offering same


U value as traditional thick insulation.

Dry lining with minimum interior space lost.

Property Value Calculator


revision 0705-03
Currency GBP

Spaceloft
8m
Thickness m 0.02

Competitive Material 8m Spaceloft


Thickness m 0.075 20 mm 20 mm
8m 75 mm
Building Dimensions
Height m 2.4
Value per m2 GBP/m2 6000
Length/Width m 8 75 mm
NB: Calculated area assumes 10% of Wall area uninsulated (Windows,Doors,etc) Competitive Material

Competitive
Material Spaceloft Gain

Additional Internal
Area m2 2.38 0.62 1.76
Additional Volume m3 5.14 1.33 3.80
Increased Value GBP 308 2,223 10560

This calculation is for estimation purposes only. Aspen Aerogels accepts no liability for these figures

-12-
Confidential & Proprietary
Summary of Contents

Introduction to Aspen Aerogels

Key Product Attributes

Environmental Profile

Solutions

-13-
Confidential & Proprietary
Fire Performance

Spaceloft* has received a E rating in the Euroclass fire test.

The rating is determined by the reinforcement fibre


(we rate A1 with PG 6681 (silica fibre) , B with PG 6350 (Carbon fibre)

-14-
Confidential & Proprietary
Breathability & Hydrophobicity

An interesting combination.

Spacelofts unique chemistry offers both a hydrophobic performance


and in the same material an ability to breathe.

This allows for the design of both venting concepts and also installation where
water would be a problem to traditional insulation materials

Hydrophobic
Vapor permeable

Water droplet with contact


angle >150C

-15-
Confidential & Proprietary
Breathability & Hydrophobicity

Spaceloft 3mm 1548 g / 24 hr sq m


12.74E-6 g / Pa sec sq m
222.9 US Perms

Spaceloft 9mm 540 g / 24 hr sq m


4,51E-6 g / pa sec sq m
79 US Perms

-16-
Confidential & Proprietary
Breathability & Hydrophobicity

Hydrostatic Head Test

SL 9251 83 cm (mean)

SL 3251 61 cm (mean)

-17-
Compressive
CompressiveStress
StressStrain
StrainCurves.
Curves.

Figure 1. Compressive stress-strain plots for three ply stacks of SL9251 samples from
lot 267 up to 1.03 MPa (150 psi).

10% compressive strain at 70 kPa : 10% strain is 0.9mm


Confidential & Proprietary
Acoustics

Features
Features&&Benefits
Benefits
Acoustics.
0.70 35

Spaceloft* is primarily
35
Absorption Coefficient 20.0 Sound Transmission Class
0.60 30
Thickness 30
Thickness (mm)

a thermal insulator
0.50 25
15.0 25

0.40 20
20

10.0

in certain combinations
0.30 15 15

0.20 10 10
5.0

the acoustic effect is very positive.


0.10 5 5

0.00 0 0.0 0

Mineral Wool
Melamine

Fiberglass
PG 6350

PG 6650

CG 6000
SL 9200C

SL 6250C

PG 4250C

CG 6000C
Melamine

Mineral
Fiberglass
PG 6350

PG 6650

CG 6000
SL 9200C

SL 6250C

PG 4250C

CG 6000C

Wool
Transmission loss Key acoustic performance properties
0.0200
0.0180

0.0160
Material Loss Coeffient (Damping)
Thickness (mm)
30

25

and Absorption, Transmission Loss, Damping


0.0140

0.0120
20

Aspen aerogel materials demonstrate good


damping are SLs
0.0100 15
0.0080
acoustic performance at lower thicknesses 0.0060
10

than competitive insulation materials.


strongest acoustic attributes.
0.0040
5
0.0020

0.0000 0

SL 9200C

CG 6000C

SL 6250C

PG 4250C
PG 6650

Melamine

CG 6000

PG 6350
Fiberglass
Mineral Wool
confidential & proprietary

-19-
Confidential & Proprietary
Health & Safety

Dust Concerns.

Aerogels are susceptible to dustiness

Aerogel nanotechnology is based on nano-porosity NOT nano-particulate

The pore size is +-20 nano-meters , the dust size is measured in Microns

Percent of Material retained on the


sieve.
Cumulative
Moisture Total of Actual Sieving Sieve Pan
Material Sample Content (% Weight After Time Sieve #100 #200 Sieve #325 (-325 mesh)
Tested Wt. (gm) by wt.) Testing (gm) (min) (150m) (75m) (45m) < 45 m
Aerogel
100.0 1.2 99.9 30 53.8 33.0 10.5 2.7
Dust

Dust analysis from Aerogel workshop environment , report by Safety Consulting Engineers inc.

-20-
Confidential & Proprietary
Health & Safety

Aerogel dust is classified as non irritant

EXECUTIVE SUMMARY
ET-50 Expected In vivo
SAMPLE (hrs) Irritancy
07050160 Spaceloft 6251 > 24.0 Non-Irritating
07050162 Pyrogel 6651 x
Hitox > 24.0 Non-Irritating
07050161 Pyrogel 6350 > 24.0 Non-Irritating
1.0% Triton X-100 8.9 Moderate to Mild

ET-50 (hrs) Expected In vivo Irritancy


<0.5 Severe, Probable corrosive
0.5 -- 4 Moderate
4 -- 12 Moderate to Mild
12 -- 24 Very Mild
24 Non-Irritating

Epiderm MB# 07-15852.19 test on SL 6251 & PG 6350


Report by MB Research Laboratories

-21-
Confidential & Proprietary
Health & Safety

Aerogels do not support mould growth

ASTM C1338 test on SL 9251


-22-
Confidential & Proprietary
Summary of Contents

Introduction to Aspen Aerogels

Key Product Attributes

Environmental Profile

Solutions

-23-
Confidential & Proprietary
Environmental/Sustainability

Spaceloft* has been rated as silver C2C.

Spaceloft* has ZERO Ozone Depleting Potential (ODP).

Spaceloft* has a Global Warming Potential of less than 5.

Spaceloft* X251 is fully recyclable

Aerogel as fill insulation: used as particulate form insulation.


Polyester fibers: returned to industrial PET manufacturing process.

The batting reinforcement of Spaceloft* X251 is made of recycled industrial material.

Spaceloft* is a relatively low energy to produce material. 5,4 kg of CO2/sq mt 10mm

Spaceloft* is fully compliant with RoHS.

-24-
Confidential & Proprietary
Embodied Energy & Embodied CO2 of Aerogel blankets

Aerogel
Raw Materials
35.5 MJ/kg
3.24 kg/kg
Gel Composite
Sol Fibrous
Reinforcement
12.1 MJ/kg Manufacturing
0.59 kg/kg 6.3 MJ/kg
0.46 kg/kg
Component Embodied Energy Embodied CO2
MJ/kg kg/kg
Silica precursor and other raw materials 35.5 3.2
Batting (fibrous reinforcement) 12.1 0.6
Aspen Aerogels Production Process 3.5 0.4
CO2 for Supercritical Extraction* 2.1 -
Pollution control equipment 0.7 0.03
Transport from US to Europe** 2.2 0.14
Transport
*CO2 recovered from other external industrial processes 2.2 MJ/kg
**Assumes 6000 km by cargo ship, 500 km by road 0.14 kg/kg
Total: 56 4.4

Spaceloft X251

Embodied
EmbodiedCO2
CO2==5,4
5,4kg
kg//sq
sqmt
-25- mtof
ofSL
SL9251
9251
Confidential & Proprietary
EE & ECO2 Comparison
Thermal EE per Ther. Res. ECO2 per Ther. Res.
Thermal Resistance ECO2 (kg of
Material Conductivity EE (MJ/kg) (EE/R-value per (ECO2/R-value per
(R-value per inch) 1 CO2/kg)
(mW/m-K) 1 inch) inch)
1 1
Spaceloft X251 12 12.0 53.0 4.2 4.42 0.35
2 2
Fiberglass (recycled glass) 40 3.8 28.0 1.4 7.37 0.36
2 2
Fiberglass (virgin glass) 40 3.8 39.2 1.9 10.32 0.50
2 2
Mineral wool 40 3.8 16.6 1.2 4.37 0.32
3 2
Expanded polystyrene 32 4.5 111.6 3.0 24.80 0.67
3 2
Polyisocyanurate 24 6.0 69.8 5.5 11.63 0.92

1
Manufacturer data
2
Inventory of Carbon & Energy, University of Bath, UK
3
Comparison of Energy Evaluation of Plastic Products and Their Alternatives for the Building, Construction, and Transportation Industries - The Society of the Plastics Industry

EE of aerogel is higher than others on a mass basis, but our thermal performance is
superior, such that the energy return/payback is greater.

Typical CO2 payback time is 2 12 month in domestic refurbishment ,


dependant on fuel type and wall construction

-26-
Confidential & Proprietary
Environmental Payback in B&C

UK Domestic Energy Model , BRE/EST/Ofgem.

BREDEM CO2 saving calculations


Fuel Types
dwelling no.beds SL tkmm Gas LPG Electric Oil Coal Wtd ave
Semi-house 3 9 1,431 1,612 2,956 1,803 3,765 1,577
Semi-house 3 18 1,766 1,989 3,658 2,227 4,635 1,947
Semi-house 3 27 1,929 2,173 3,982 2,429 5,042 2,125
Semi-house 3 36 2,029 2,285 4,173 2,553 5,288 2,234

3 bed semi = 82 sq mt of wall = 82 * 5, 4 KG of embodied CO2 = 445 kg

SL 9251 CO2 payback = 445/1,577 = 0,3 years = 3,4 months.

-27-
Confidential & Proprietary
Spaceloft* B&C Summary

Spaceloft* offers the highest passive thermal insulation achievable today.

Spaceloft* is a robust material suitable for a variety of B&C applications and


installation techniques.

Spaceloft* potentially offers solutions for the application areas presently deemed
Hard To Treat due to space restriction.

Spaceloft* offers an energy & CO2 payback in less than 12 month for typical
B&C applications.

The longevity of the insulation performance makes Spaceloft& ideally suited


to the construction industry.

Spaceloft* offers a sustainable, recyclable & environmental responsible solution


for the Building & Construction industry

If you value space youll love Spaceloft*

-28-
Confidential & Proprietary
Summary of Contents

Introduction to Aspen Aerogels

Key Product Attributes

Environmental Profile

Solutions

-29-
Confidential & Proprietary
Spaceloft B&C Summary

Roofs/Loft conversions
under tile

Walls internal
external

Floors heated
thin
cold bridges
Terraces

Timber Frame

Metal Frame

-30-
Confidential & Proprietary
Case Study.

UK Social Housing Project

Spaceloft* applied as the SpaceTherm


laminate from A Proctor Group.

CO2 pay back for these appartments


8 months.

Insulated apartment on left

-31-
Confidential & Proprietary
Solid wall (9 brickwork)

60% reduction in line with Climate Change Bill proposals


Wall construction equates to upgraded U value of 0.84 W/mK

Spacetherm P
(10mm Space Loft
SL9251 + 9.5mm U value estimation
plasterboard) Structure Thickness U value
mm W/ m2h improvement
Solid Wall 215 2.1
SW + 1 layer Spacetherm 240 0.8 62%
SW + 2 layer Spacetherm 250 0.49 77%
SW + 3 layer Spacetherm 260 0.35 83%
215mm SW + 4 layer Spacetherm 270 0.29 86%
brickwork

60-85 % U value
reduction

-32-
Confidential & Proprietary
Case Study. External Cladding

NEA sponsored project.

Spaceloft* applied as ParaClad


of the Parasol company.

CO2 pay back for this park home


4 months.

No thermal bridges

-33-
Confidential & Proprietary
Solid wall (9 brickwork)
13mm of Paraclad
60% reduction in line with Climate Change Bill proposals
equates to upgraded U value of 0.84 W/mK
Wall construction

13mm plaster
Material Thickness Thermal Thermal
(mm) Conductivity Resistance
(W/mK) (m2K/W)

Internal Surface Ri 0.130

Plaster 13 0.57 0.023

Brickwork 215 0.77 0.279

13mm Paraclad 13 0.706*

Paraclad
External Surface Ro 0.04

Total R 1.178

U Value 0.739

* As measured by NPL Sep 17 2007

215mm
brickwork 65% U value
reduction
-34-
Confidential & Proprietary
External Rendering

Fast Installation

Multiple layers

Minimum joints

Minimum reveal/fitting disruption

-35-
Confidential & Proprietary
External Rendering

Robust site storage

Mushroom & Mesh


-36-
Confidential & Proprietary
Internal rendering.

Wet Primer Layer 1 Wet Positioning Internal Plasters mesh

2 Mechanical Fixation

-37-
Confidential & Proprietary
Internal Render

Final Plaster Layer

Creates Space.

Tackles Thermal Bridges

-38-
Confidential & Proprietary
Internal Render

-39-
Confidential & Proprietary
Underfloor Heating
Radiant Floor Power Usage

Control Floor

0.18
Spaceloft 3251

0.16 Spaceloft 9251

r 0.14
u
o
/h 0.12
h
w
K 0.10
-
e
g
a
s
0.08

U
re 0.06
w
o
P 0.04
0.02

0.00

Up to 60% energy savings


Thin set Mortar / Radiant Flooring
Fast heating cycle SpaceLoftTM X251

Minimum height disruption

Very fast installation Cement Slab

-40-
Confidential & Proprietary
Renovation of basement : Fast & Cost effective installation

-41-
Confidential & Proprietary
Renovation of basement : Fast & Cost effective installation

No disruption to door fittings

-42-
Confidential & Proprietary
Thermal Bridging , brick & block

Solid cast concrete floor , thermal bridge .

Spaceloft applied externally

Spaceloft applied internally

-43-
Confidential & Proprietary
Thermal Bridging : Timber Frame , Spaceloft Insulcap

With

Without

-44-
Confidential & Proprietary
Thermal Bridging : Metal Frame , Spaceloft Insulcap

Oak Ridge National Laboratory

2007 JM Hot Box Test:


Baseline with Spider R-7.7 hft2 F/Btu
Baseline plus 9mm Aerogel R-11 hft2 F/Btu
42%
improvement
-45-
Passive
PassiveHouse
House, ,High
Highperformance
performanceterrace/roof
terrace/roof

Baechi Holz Bau , Erlenbach , Switzerland.

Timber framed insulated roof to meet Passive House status, 2 layers SL 9251

Construction : December 2007

2 layers of SL 9251 + MF (to protect from bitumen seal process)

SL Mineral Fibre Wooden slats Water drain 1 piece 15mt terrace


Confidential & Proprietary
Passive House : vertical wall (replacement of VIP)

Blumer & Lehmann , timber frame housing constructor , Gossau , CH

Site : Mielen , Zurich , high performance thin wall design , 4 layers SL 9251

Constructed , Dec 2007


Ship lap to avoid
Vault set up Rotary blade Thermal bridging

-47-
Confidential & Proprietary
Spaceloft* B&C Summary

Spaceloft* offers the highest passive thermal insulation achievable today.

Spaceloft* is a robust material suitable for a variety of B&C applications and


installation techniques.

Spaceloft* potentially offers solutions for the application areas presently deemed
Hard To Treat due to space restriction.

Spaceloft* offers an energy & CO2 payback in less than 12 month for typical
B&C applications.

The longevity of the insulation performance makes Spaceloft& ideally suited


to the construction industry.

Spaceloft* offers a sustainable, recyclable & environmental responsible solution


for the Building & Construction industry

If you value space youll love Spaceloft*

-48-