You are on page 1of 5

STEP 1

SHELL S17 & S18 Cold Stream


TUBE S9 & S10 Hot Stream

STEP 2
TUBE
Properties Inlet (S9) Mean Outlet (S10)
Temperature (K) 733.832 632.6645 531.497
Pressure 0
Specific Heat ( KJ/kg.K) 1.96392 2.437585 2.91125
Thernal Conductivity (W/m.K) 0.062748 0.097461 0.132174
Density (Kg/m3) 2.87112 498.7251 994.579
Viscosity (mNSm-2) 0.025143 2.463136 4.90113
Mass Flow Rate (kg/s) 11.5084 7.311625 3.11485

SHELL
Properties Inlet (S17) Mean Outlet (S18)
Temperature (K) 312.559 392.8545 473.15
Pressure 0
Specific Heat ( KJ/kg.K) 2.69359 2.82583 2.95807
Thernal Conductivity (W/m.K) 0.172729 0.160684 0.148638
Density (Kg/m3) 990.359 1018.995 1047.63
Viscosity (mNSm-2) 59.8894 48.1394 36.3894
Mass Flow Rate (kg/s) 7.48652 5.423725 3.36093

STEP3
OVERALL HEAT TRANSFER COEFFICEINT
U (W/m2c) 700 300

STEP 4
Exchanger Dimensions

Tlm X FT

Tlm = 41.744 = 239.2032


0.174513
R= 1.25994

S= 0.381204

In graph plot = FIGURE 12.19


FT = 0.91

Tm = 217.6749

STEP 5
HEAT TRANSFER AREA
TUBE SIDE:
Q= mCpT
m= 11.5084
Cp = 1.96392
T = 202.335
Q= 4573.09

Heat Transfer Area


Ao = Q/ UTm
0.030013

STEP 6
Layout and Tube Size

Properties Dimensions
Material of Construction Carbon Steel
Length of Tube, lt (m) 5
Inner Diameter of Tube, Dti (m) 0.01483
Outer Diameter of Tube, Dto (m) 0.01905
Pitch, Pt (m) 0.023185
Tube Arrangement Equilateral Triangular

Pitch of fixed tube heat exchanger:


Pitch = 1.25 X Outer Diameter of tube
0.023813

STEP 7
Number of Tubes
Area = LD
= 3.142
D= 1.91E-02

Area = 0.299276

Nt = Ao = 0.100284
Area