Professional Documents
Culture Documents
STEP 2
TUBE
Properties Inlet (S9) Mean Outlet (S10)
Temperature (K) 733.832 632.6645 531.497
Pressure 0
Specific Heat ( KJ/kg.K) 1.96392 2.437585 2.91125
Thernal Conductivity (W/m.K) 0.062748 0.097461 0.132174
Density (Kg/m3) 2.87112 498.7251 994.579
Viscosity (mNSm-2) 0.025143 2.463136 4.90113
Mass Flow Rate (kg/s) 11.5084 7.311625 3.11485
SHELL
Properties Inlet (S17) Mean Outlet (S18)
Temperature (K) 312.559 392.8545 473.15
Pressure 0
Specific Heat ( KJ/kg.K) 2.69359 2.82583 2.95807
Thernal Conductivity (W/m.K) 0.172729 0.160684 0.148638
Density (Kg/m3) 990.359 1018.995 1047.63
Viscosity (mNSm-2) 59.8894 48.1394 36.3894
Mass Flow Rate (kg/s) 7.48652 5.423725 3.36093
STEP3
OVERALL HEAT TRANSFER COEFFICEINT
U (W/m2c) 700 300
STEP 4
Exchanger Dimensions
Tlm X FT
S= 0.381204
Tm = 217.6749
STEP 5
HEAT TRANSFER AREA
TUBE SIDE:
Q= mCpT
m= 11.5084
Cp = 1.96392
T = 202.335
Q= 4573.09
STEP 6
Layout and Tube Size
Properties Dimensions
Material of Construction Carbon Steel
Length of Tube, lt (m) 5
Inner Diameter of Tube, Dti (m) 0.01483
Outer Diameter of Tube, Dto (m) 0.01905
Pitch, Pt (m) 0.023185
Tube Arrangement Equilateral Triangular
STEP 7
Number of Tubes
Area = LD
= 3.142
D= 1.91E-02
Area = 0.299276
Nt = Ao = 0.100284
Area