You are on page 1of 1

Unit:mm

Type Class L() H() W


Gate 150
300
1500
Globe 150
300
1500

PI

PI

Tested Valves ( 6) TEST SEQUENCE


NOTES Each Gate and Globe valves NPS 2 for rating 150, 300, 1500# 1. Tested Valve . ( )
APPLICATION CODE FOR FIRE TESTING : API 6FA_2009 ED.
2. Tested Valve Cavity .
MAXIMUM PRESSURE RATING : ASME CL.1500
3. Test Valve Vent & Drain Valve Close .
MAXIMUM TESTING PRESSURE : 186.2 BAR 4. Test Valve Closed .
TESTING MEDIA : WATER 5. Test Valve Drain Valve Open Downstream Line Drain .
MAXIMUM TESTING TEMPERATURE : From Room Temp. to 761 C within 2 minutes. 6. . Leak .
: Thermocouple 2, Calorimeter 2 4. 7. , Vessel , .
8. Open .
Thermocouple : 761 C 2 . (761~980C)
Calorimeter : 650 C 15 .
9. 30 Fire Test .
10. ( ), Thermocouple & Calorimeter 30 .
11. 30 , .
12. , 10 100C .
13. , .
14. Open/Close Closed 5 .
15. 5 .