You are on page 1of 3

Project Name: DESIGN OF MANHOLES

BIN OMRAN TRADING & CONTRACTING


Client:
L.L.C
Designed by: JTT Checked by: LBV
Date: 31-Oct-17 Date: 2-Nov-17

SKIN FRICTION LOADS CALCULATION

A. FROM LATERAL EARTH PRESSURE


*neglecting skin friction at upper shaft

STAAD Force, PE = 17.1 kPa


Outside Diameter of Manhole, D = 2.4 m
Height of lower shaft, H = 2.5 m
H
Coefficient of Skin Friction, = 0.25
f1
F1 Number of Nodes in STAAD = 12 nodes
PE

Resultant Force, f1 = 1/2 x 17.1 kPa x 2.5m = 21.38 kN/m


Frictional Resistance, F1 = 0.25 x 21.375 x x 2.4 = 40.29 kN
STAAD Nodal Load = 40.291kN / 12 = 3.36 kN

B. FROM LIVE LOAD SURCHARGE LOAD:

STAAD Force, PL = 7.60 kPa

H f2
F2
PL

Resultant Force, f2 = 7.6 kPa x 2.5 m = 19 kN/m


Frictional Resistance, F2 = 0.25 x 19 x x 2.4 = 35.81 kN
STAAD Nodal Load = 35.814 kN / 12 = 2.98 kN
Project Name: DESIGN OF MANHOLES
BIN OMRAN TRADING & CONTRACTING
Client:
L.L.C
Designed by: JTT Checked by: LBV
Date: 31-Oct-17 Date: 2-Nov-17

SKIN FRICTION LOADS CALCULATION

A. FROM LATERAL EARTH PRESSURE


*neglecting skin friction at upper shaft

STAAD Force, PE = 82.1 kPa


Outside Diameter of Manhole, D = 2.4 m
Height of lower shaft, H = 12 m
H
Coefficient of Skin Friction, = 0.25
f1
F1 Number of Nodes in STAAD = 24 nodes
PE

Resultant Force, f1 = 1/2 x 82.1 kPa x 12m = 492.60 kN/m


Frictional Resistance, F1 = 0.25 x 492.6 x x 2.4 = 928.53 kN
STAAD Nodal Load = 928.529kN / 24 = 38.69 kN

B. FROM LIVE LOAD SURCHARGE LOAD:

STAAD Force, PL = 7.60 kPa

H f2
F2
PL

Resultant Force, f2 = 7.6 kPa x 12 m = 91.2 kN/m


Frictional Resistance, F2 = 0.25 x 91.2 x x 2.4 = 171.91 kN
STAAD Nodal Load = 171.908 kN / 24 = 7.16 kN
Project Name: DESIGN OF MANHOLES

COMPANY LOGO Client:


Designed by: - Checked by: -
Date: - Date: -

SKIN FRICTION LOADS CALCULATION

A. FROM LATERAL EARTH PRESSURE


*neglecting skin friction at upper shaft

STAAD Force, PE = 150.5 kPa


Outside Diameter of Manhole, D = 2.7 m
Height of lower shaft, H = 22 m
H
Coefficient of Skin Friction, = 0.25
f1
F1 Number of Nodes in STAAD = 32 nodes
PE

Resultant Force, f1 = 1/2 x 150.5 kPa x 22m = 1655.50 kN/m


Frictional Resistance, F1 = 0.25 x 1655.5 x x 2.7 = 3510.61 kN
STAAD Nodal Load = 3510.612kN / 32 = 109.71 kN

B. FROM LIVE LOAD SURCHARGE LOAD:

STAAD Force, PL = 7.60 kPa

H f2
F2
PL

Resultant Force, f2 = 7.6 kPa x 22 m = 167.2 kN/m


Frictional Resistance, F2 = 0.25 x 167.2 x x 2.7 = 354.56 kN
STAAD Nodal Load = 354.56 kN / 32 = 11.08 kN