Replace HydraForce Valve with Argo-Hytos

This document provides installation instructions to replace an existing HydraForce steering mode selector valve with a new Argo-Hytos valve. The 15 step process involves removing the old valve, marking hydraulic lines for reconnection, drilling holes for the new valve, installing fittings on the new valve, mounting the valve, and reconnecting hydraulic lines before testing. Safety precautions are provided to protect hoses and ensure proper valve function.

Uploaded by

walk111
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
121 views4 pages

Replace HydraForce Valve with Argo-Hytos

This document provides installation instructions to replace an existing HydraForce steering mode selector valve with a new Argo-Hytos valve. The 15 step process involves removing the old valve, marking hydraulic lines for reconnection, drilling holes for the new valve, installing fittings on the new valve, mounting the valve, and reconnecting hydraulic lines before testing. Safety precautions are provided to protect hoses and ensure proper valve function.

Uploaded by

walk111
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

JEFFREY - STEER MODE SELECTOR VALVE

REPLACING HYRAFORCE WITH ARGO-HYTOS

REMOVAL AND INSTALLATION PROCEDURE


(REV A JUNE 2013)
PROCON JEFFREY - FIELD INSTALLATION

PAGE DESCRIPTION: STEERING MODE SELECTOR VALVE - REPLACEMENT OF HYRAFORCE WITH ARGO-HYTOS
FI-01

The purpose of this document is to outline the steps required to replace the former (HydraForce)
steering mode selector valve with the updated (Argo-Hytos) steering mode selector valve.

STEP 1 - With unit parked on flat stable ground, open


the hood.

STEP 2 - Remove the operator compartment steering valve


cover bolts (x9) and set cover and bolts aside for
reinstallation at a later step. Fig. FI101

Fig. FI103

!
CARE MUST BE TAKEN WHEN DRILLING/CUTTING
TO ENSURE HOSES/CABLES ARE TIED UP AND
ARE OUT OF THE WAY. FAILURE TO DO SO MAY
CAUSE DAMAGE TO HOSE ASSEMBLIES
3
STEP 6 - Mark & drill/cut the 2x 8" and
1
Fig. FI101 1x 1 2 " holes in the operators compartment
as shown in diagrams below: (SEE WARNING
STEP 3 - Remove the control knob and collar from the INFORMATION AT STEP 12)
HydraForce valve by removing the single pan-head 3
215 16 in 8 in (2x Typ.)
screw and the 2 set screws from the knob.
Discard these parts.

Edge of operator
STEP 4 - Mark/Tag the 4 hydraulic lines as shown for later compartment
connection to Argo-Hytos valve assembly:
(Fig. FI102)
11 2 in
C

DETAIL C

Edge of operator Edge of operator


compartment 313 16 in compartment

Fig. FI102 51 2 in
D
STEP 5 - Detach the hydraulic lines from the valve and 1
remove the valve/bracket from the operators 1 2 in
compartment by removing the 2x bolts as
shown: (Fig. FI103)

DETAIL D

CONTINUED ON PAGE FI-02

REV A JUNE 2013


PROCON JEFFREY - FIELD INSTALLATION

DESCRIPTION: STEERING MODE SELECTOR VALVE - REPLACEMENT OF HYRAFORCE WITH ARGO-HYTOS PAGE
FI-02
CONTINUED FROM PAGE FI-01

STEP 7 - Install 4x fittings into valve base as STEP 10 - Install rubber dust boot into
1
1 2 " hole
shown Fig. FI104. cut in step 6.
Fittings: 002H179 - FITTING, #6 MORB - #6 MJIC ELBOW 90DEG
STEP 11 - Use channel-lock or vise-grip pliers to
remove the plastic control knob from the
lever stem. Fig. FI107.

STEP 12 - With the valve, base w/fittings , and bracket all


assembled, mount assembly to operators
1
compartment using 3x ea. 4 "UNC x 1" HHCS and
1
4" lockwashers. Re-install control lever knob. Fig. FI107.

Note: : Control lever must be centered into hole in operator


1
compartment 8 ". Make adjustments as necessary to achieve

Fig. FI104 concentricity. Failure to do so will result in malfunction.

STEP 8 - Mount the valve base to the bracket as


1
shown using 2x ea. 4 UNC x 1" SHCS and
1
4 UNC nuts. Use Loctite thread locker compound
to secure nuts. Fig. FI105.

Note: Observe orientation of valve ports below:

Fig. FI107

Ensure that control lever will fully engage

! in each of the 3 positions. Make adjustments


if necessary. Failure to do so may result in
undesired function while in operation.

Fig. FI105 STEP 13 - Reconnect the hoses disconnected


in step 5 as follows: (More information on page FI-03)

STEP 9 - Mount the valve assembly to the base as shown Hose #1 to port fitting "P" (HOSE 002K066)
1
using 4x ea. 10-24 x 1 2 " Socket head machine Hose #2 to port fitting "B" (HOSE 002K056)
screws and #10 hi-collar washers. Fig. FI106. Hose #3 to port fitting "T" (HOSE 002K087 ST)
(HOSE 002K071 MT)
Note: Align dowel hole in valve assembly with dowel (HOSE 002K088 LT)
hole in base. Orientate as shown: Hose #4 to port fitting "A" (HOSE 002K090 ST)
(HOSE 002K089 MT)
(HOSE 002K085 LT)

STEP 14 - Test the valve functions and ensure that


there are no leaks.

STEP 15 - Re-install the operators compartment


steering valve cover that was removed
in step 2

Fig. FI106
CONTINUED ON PAGE FI-03

REV A JUNE 2013


PROCON JEFFREY - FIELD INSTALLATION

PAGE DESCRIPTION: STEERING MODE SELECTOR VALVE - REPLACEMENT OF HYRAFORCE WITH ARGO-HYTOS
FI-03

STEP 16 - Remove the original steer mode graphics &


warning information plate and replace with
the updated/resized steer mode graphic &
information plate. "Front" steering graphic
should be centered above the valve control
lever as shown: Fig. FI108

STEP 17 - Install the "blank" cover plate as shown


to seal the compartment. Fig. FI108