PASOLINK
6-38 GHz 155 MB DIGITAL RADIO SYSTEM
(1 + 0 / 1 + 1 SYSTEM)
NEC Corporation
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM
TABLE OF CONTENTS
LIST OF ABBREVIATIONS..............................................................ii
1. INTRODUCTION ............................................................................................................... 1
2. FEATURES......................................................................................................................... 3
2.1 Advanced Technologies and Superb Performance ........................................................ 3
2.2 High System Gain............................................................................................................ 3
2.3 Easy and Quick Installation ............................................................................................. 3
2.4 Common platform architecture ....................................................................................... 3
2.5 Frequency Agility and Easy Tuning ................................................................................. 3
2.6 TX Power Control ............................................................................................................ 3
2.7 System Flexibility ............................................................................................................. 3
2.8 Maintenance Facilities ..................................................................................................... 4
2.9 Service Channels (Please see 4.2 Service Channel for available channel)................... 4
2.10 Electromagnetic Compatibility (EMC).......................................................................... 4
2.11 Conformity with the ITU................................................................................................ 4
3. RELIABILITY AND QUALITY............................................................................................ 7
4. INTERFACE........................................................................................................................ 9
4.1 Digital Signal Interface..................................................................................................... 9
4.2 Service Channel (SC).................................................................................................... 10
4.3 RF Port .......................................................................................................................... 10
4.4 Alarm Signal Interface.................................................................................................... 10
5. DESIGN CONSIDERATIONS ......................................................................................... 11
5.1 Protection Capability...................................................................................................... 11
5.2 Antenna.......................................................................................................................... 11
5.3 Transmitter-Receiver (ODU) ......................................................................................... 11
5.4 Indoor Unit (IDU) ............................................................................................................ 12
5.5 Other Tools and Materials ............................................................................................. 13
5.6 Option Panel .................................................................................................................. 14
6. PERFORMANCE.............................................................................................................. 21
6.1 Performance.................................................................................................................. 21
6.2 IDU................................................................................................................................. 23
6.3 Service Channels (Please see 4.2 Service Channel for available channels).............. 23
6.4 General .......................................................................................................................... 24
6.5 Events ............................................................................................................................ 25
6.6 Indication........................................................................................................................ 25
6.7 House Keeping Alarm/Control Interface........................................................................ 26
6.8 Alarm Items.................................................................................................................... 27
6.9 Performance Monitoring/Metering Items........................................................................ 28
- i-
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005
LIST OF ABBREVIATIONS
AMI Alternate Mark Inversion Ethernet LAN specification along
IEEE802.3
ANT Antenna
FEC Forward Error Correction
APC Automatic Phase Control
FIL Filter
ATPC Automatic Transmitter
Power Control FOTS Fiber Optical Transport
System
ATT Attenuator
HDB3 High Density Bipolar order 3
B8ZS Binary 8-Zero Substitution
HIC Hybrid Integrated Circuit
BACK-
Pressure Anti-congestion control HYB Hybrid
- ii -
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM
- iii -
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005
- iv -
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM
1. INTRODUCTION
+
NECs new PASOLINK series; 6-38 GHz 155 Mbps Synchronous Digital Hierarchy (SDH)
microwave radio systems are designed to transmit one synchronous transport module (STM-
1, 155 Mbps). They operate at the 6-38 GHz radio frequency band using quadrature amplitude
modulation (32-QAM or 128-QAM), and have a transmission capacity of OC3 or STM-1. In
+
addition to the PASOLINK systems for short distance links, NEC offers a complete product
line of STM-1 radio systems that includes the 4, L6, 7, 8, 13 GHz 155 Mbps 128 QAM and 4,
5, U6, 8, 11 GHz 155 Mbps 64 QAM systems for long distance use. For those systems,
please refer to the other technical descriptions.
+
The PASOLINK radio systems are fully compatible with SDH Network Elements (NE). The
systems consist of antennas, outdoor units (ODU), and indoor units (IDU). They are
connected through a coaxial cable for each radio channel. Available configurations are non-
protection type (1 + 0) and protection type (1 + 1). The protection type is available for twin-
path type and hot-standby type.
Regarding antenna configurations there are two types available. There is a one-antenna
system employing hybrid (HYB) RF combiner and divider, and a two-antenna system method
using each antenna for two ODUs independently. The hybrid is the passive device that
combines and divides the signals between two ODUs and an antenna. Therefore, the one-
antenna system requires only a single antenna, however, additional loss between ODUs and
antenna have to be considered. On the other hand, the two-antenna system has high system
gain as same as non-protection type.
+
STM-1 interface can be selected for electrical or optical. Therefore, PASOLINK systems are
useful in fiber optical transport system (FOTS). Additionally, Fast Ethernet interface can be
selected for IP network.
+
The PASOLINK employs a full digital MODEM using enhanced signal processing techniques
and forward error correction (FEC). Moreover, the bit-error-rate characteristics against
receiver input signals are excellent for applying FEC (32-QAM System: MLCM (multi-level
code modulation) and RS (Reed Solomon method), 128-QAM System : QAM and RS).
The equipment can be installed easily and quickly using a PC (as Local Craft Terminal), and
as a maintenance tool.
-1-
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005
Type 1 Type 2
11-38 GHz 128 QAM/32 QAM type 6-8 GHz 128 QAM type
(0.3m Diameter Antenna) (Low Loss Coaxial cable connection to Antenna)
-2-
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM
2. FEATURES
(In case of 1+1 Hot-standby or twin-path system, either one antenna system with hybrid
combiner or two antenna system excluding hybrid combiner is chosen. Please refer to Fig. 3
(a), (b).)
1 + 1 Hybrid combiner: NEC provides 3 dB balance-type hybrid combiner.
-3-
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005
IF, Baseband (near end, far end) loop back (without external equipment)
Remote monitoring of ODU operating condition on IDU
Calling facility between IDUs
2.9 Service Channels (Please see 4.2 Service Channel for available channel)
Order Wire : IDU-IDU/IDU-ODU/ODU-ODU party line connection
(EOW) (EOW system using PASOLINK MONITOR (option) at ODU)
Digital Port : 64 kbps Sync., 2 ch standard
VF Port : 0.3 to 3.4 kHz (1 ch) 600 ohms, 2 ch standard
Wayside : 2.048/1.544 Mbps, 1 ch (optional at 32 QAM STM-1)
10 Base-T : 1 ch (optional; exclusive use in other service channels)
Cluster Alarm : 2 ch (optional; auxiliary alarm transmission)
ODU 1
HYBRID
ODU 2
ANTENNA
+
Figure 3(a). Ways to Mount the 1 + 1 PASOLINK using a single Antenna
-4-
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM
+
Figure 3(b). Ways to Mount the 1 + 1 PASOLINK using two Antennas
-5-
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005
-6-
+
MTD-PL-028/1401005 PASOLINK 155 MB 1+0/1+1 SYSTEM
+
NECs PASOLINK utilizes advanced VLSI, MIC and MMIC technology for all-solid-state
circuitry from data input to RF output.
NEC plants are located all over the world, and quality control is carefully monitored in every
manufacturing step, such as parts selection, assembly, adjustment and testing. NEC Quality
Controls employing Zero Defect and Value Engineering Techniques extend to every aspect of
production and inspection in accordance with stringent Total Quality Control programs. In
addition, NEC plants have obtained ISO 9001 certifications.
-7-
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005
-8-
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM
4. INTERFACE
+
The NEC PASOLINK system has the ITU-T standard interface conditions as listed below:
4) SOH Termination
-9-
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005
4.3 RF Port
Interface
- 10 -
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM
5. DESIGN CONSIDERATIONS
+
PASOLINK provides a protection switching system of Hot-standby protection (1 + 1), and
twin-path protection (1 + 1).
1. Non-Protection System
Non-protection system consists of one ODU, one IDU for 1 + 0 System, and one antenna.
2. Hot-Standby System
Hot-Standby system consists of two ODUs, one IDU for 1 + 1 system, and one or two sets of
antennas. The protection switch of this systems is performed by the TX switches on the
ODUs at the transmitting end and Hitless switch on the 150 M INTFC (or OPT INTFC) module
in the IDU at the receiving end.
3. Twin-path System
Twin-Path system consists of two ODUs, one IDU for 1 + 1 System, and two sets of
antennas. The protection switch of this system is performed by the Hitless switch on the 150
M INTFC (or OPT INTFC) module in the IDU at the receiving end.
5.2 Antenna
+
The complete menu of PASOLINK antennas includes diameters of 0.3m to 1.8m. They are
designed to meet stringent requirements on mechanical rigidity. Antennas with diameters of
0.3m to 1.8m can be mounted directly to the ODU, making waveguides obsolete. This has
relevant cost and reliability merits and makes the installation quicker and easier. The
+
PASOLINK pole mounting structure is designed in a way that the ODU can be replaced while
keeping the antenna and mounting bracket, including orientation, in place. The reflectors of the
antennas are covered with white diffusive paint and the mounting structure is hot-dip
galvanized.
In the 6 - 8 GHz band, coaxial or waveguide cable with transducer is used for connecting
between the ODU and IDU.
The transmitter-receiver is designed to handle a STM-1 signal in 6-38 GHz bands. The
equipment is designed to withstand severe weather conditions.
32/128-Quadrature amplitude modulation (32/128 QAM) is applied.
Local Oscillator is employed for APC (Automatic Phase Control) loop circuit at the transmitter
and receiver.
- 11 -
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005
The IDU consists of six (6) panels that have following functions. (Figure 4-1)
1. ODU INTFC
4. CTRL
Ethernet interface (10 Base-T) card with bridge function (exclusive use against WS
interface)
- 12 -
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM
7. DC-DC CONV
Converting 48 VDC (option 24 VDC) input voltage to several internal utilizing voltages
1. LCT
Local Craft Terminal (LCT) is the simple provisioning and maintenance terminal for
+
PASOLINK system. LCT connects to the IDU. The LCT can control all functions and
measures all monitor levels.
2. PNMS
NEC can provide an Element Network Management tool (PNMS: PASOLINK Network
Management System). These tools can be used for maintenance and performance
monitoring. These tools consist of software for UNIX or WINDOWS NT OS.
The 5D-FB, 8D-FB, 10D-FB or 12D-FB coaxial cable (Low loss 50 ohms) serves as the
interconnection between the transmitter-receiver (ODU) and baseband unit (IDU). The cable
exchanges I/O data signals, DC power, alarm signals, control signals for frequency and TX
power, RX level and ODU primary voltage monitoring signals and a pair of orderwire signals.
Due to the use of different IF (Intermediate Frequency) for TX and RX, a single coaxial cable is
sufficient. This results in faster and easier installation.
The nominal power supply voltage is 48 VDC. The guaranteed range of the same unit is
sufficient for nominal voltage of 36 to 60 V (48 V) as well. In this way, commonality
between modules is achieved throughout the network even if different DC voltages are applied
at different locations. (24 VDC power supply is available as an option.)
PASOLINK MONITOR is used for receiving signal level monitor and ODU-IDU/ODU-ODU
EOW system. This is an installation tool for antenna direction pointing. (Receiving level can
be measured as voltage by voltmeter without PASOLINK MONITOR.)
6. Head set
- 13 -
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005
Slot Panel
1 STM-1e Electric Interface
2 STM-1/OC3 Optical Interface (S-1.1)
3 Main slot STM-1/OC3 Optical Interface (WDM Monofiber TX:1.3um RX:1.5um)
4 STM-1/OC3 Optical Interface (WDM Monofiber TX:1.5um RX:1.3um)
5 Ethernet 10 Base-T/100 Base-TX (2ch)
A Wayside 2.048 Mbps 75 ohms balance
B Wayside 2.048 Mbps 120 ohms unbalance
C Wayside 1.544 Mbps 110 ohms unbalance
D Wayside 2.048 Mbps 75 ohms balance + Cluster ALM
E Side slot Wayside 2.048 Mbps 120 ohms unbalance + Cluster ALM
F Wayside 1.544 Mbps 110 ohms unbalance + Cluster ALM
G Cluster ALM
H Ethernet 10 Base-T (2 Mbps (wayside) or 64 Kbps) (1 ch)
I Blank panel
- 14 -
MTD-PL-028/141005
ANT ANT
*2 *2
STM-1 ODU 150M INTFC/
150M INTFC/ ODU MODEM STM-1
IN/OUT OPT INTFC MODEM INTFC INTFC OPT INTFC
RF RF IN/OUT
CKT CKT
PNMS PNMS
CTRL CTRL
LCT LCT
+
*1 *1
LO CTRL CTRL LO *1 *1
WS IN/ WS INTFC WS INTFC WS IN/
OUT OUT
*1
- 15 -
*1
10Base-T LAN CARD LAN CARD 10Base-T
150M INTFC : Electrical STM-1 Interface LO : Local Oscillator RF CKT : Radio Frequency Circuit
ANT : Antenna MODEM : Modulator-Demodulator STM-1 : Synchronous Transport Module-1
CTRL : Control OPT INTFC : Optical STM-1 Interface WS INTFC : Wayside Interface (optional)
+
10/100 Base-T
PASOLINK 155 MB 1+0/1+1 SYSTEM
OW IN/OUT OW IN/OUT
+
MD UNIT ODU(No.2 CH) ODU(No.2 CH) MD UNIT
- 16 -
CONV CONV CONV CONV
*1 *1
LO CTRL CTRL LO
OW IN/OUT OW IN/OUT
STM-1
IN/OUT 150M INTFC/ ODU RF RF ODU 150M INTFC/ STM-1
MODEM MODEM
OPT INTFC INTFC CKT CKT INTFC OPT INTFC IN/OUT
*2 *2
OW IN/OUT OW IN/OUT
+
ANT ANT 10/100Base-T(X)
- 17 -
*1
*1
WS IN/ ODU ODU
WS INTFC MODEM MODEM WS IN/
OUT INTFC INTFC WS INTFC
RF RF 10/100Base-T(X) OUT
CKT CKT
*1 *1
OW IN/OUT OW IN/OUT
+
LCT LCT
+
OW IN/OUT OW IN/OUT
ANT ANT
*1 *1
- 18 -
OUT INTFC INTFC
RF RF OUT
CKT CKT
*1 *1
LO CTRL CTRL LO
OW IN/OUT OW IN/OUT
150M INTFC : Electrical STM-1 Interface LO : Local Oscillator RF CKT : Radio Frequency Circuit
ANT : Antenna MODEM : Modulator-Demodulator STM-1 : Synchronous Transport Module-1
CTRL : Control ODU : TRP( )G150MB5-2- WS INTFC : Wayside Interface (optional)
DC-DC CONV : DC-DC Converter OPT INTFC : Optical STM-1 Interface
IDU : MDP-150MB5T-2- OW : Orderwire
TX first MIX
(Depend on frequency band)
RF CKT
DUP
MPX
to/from to/from
IDU ANTENNA
RX IF BPF MIX
LNA
+
Figure 4-5. PASOLINK - ODU Block Diagram
- 19 -
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005
- 20 -
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM
6. PERFORMANCE
6.1 Performance
Range 5.9 8.5 10.7 11.7 12.75 13.25 14.25 15.35 17.7 19.7 21.2 23.6 24.25 27.0 37.0 40.0
(GHz)
TX Output Power (dBm) 6/7/8 GHz, 11/13/15 GHz : Guarantee Value : 2 .0 dB
18 GHz : Guarantee Value : +2.0, -1.0 dB
23/26 GHz : Guarantee Value : 2.0 dB
38 GHz : Guarantee Value : 3.0 dB
STM-1 - - - - 18 18 17 13.5
STM-1 25 16.5 16.5 16.5 15 15 14 10.5
(N.B)
STM-1 - - 18 18 19 19 18 14.5
(NB), High
power ver.
(optional)
Receiver Threshold (dBm) at 10-6 BER (Guarantee Value : +3dB)
STM-1 - - - - -76 -76 -75.5 -74
STM-1 -68 -67 -67 -67.5 -67.5 -67.5 -67 -66
(N.B)
at 10 -3 Above value -1 dB
BER
System Gain (dB) at 10-6 BER (*1) (Guarantee Value : -3dB)
STM-1 - - - - 94 94 92.5 87.5
STM-1 93 83.5 83.5 84 82.5 82.5 81 76.5
(N.B)
STM-1 - - 85 85.5 86.5 86.5 85 80.5
(NB), High
power ver.
(optional)
at 10 -3 Above value + 1 dB
BER
Frequency +/-6 ppm (+/- 0.0006%) (Typical), +/-10 ppm (+/- 0.001%) (Guarantee)
Stability
Tuning Center- Up to 50 MHz Up to 370 MHz (Depend on T-R spacing)
Bandwidth tuned (Depend on T-R spacing)
N.B: Narrow band
*1. In case of using a NEC BR CKT for 1 + 1 Hot-standby configuration, additional loss of 7 dB (typical) will be
considered.
- 21 -
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005
- 22 -
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM
6.2 IDU
Interface Connector
Item Physical Electrical
IF signal in/out Type N female -
STM-1 electrical IEC169-13 (1.6/5.6) ITU-T G.703
STM-1 optical FC/PC optical connector ITU-T G.957
Ethernet (MAIN) RJ45 10 Base-T/100 Base-TX
Ethernet (SC/WS) RJ45 10 Base-T
WS D-sub 9 pin ; (female) ITU-T G.703
Cluster ALM IN/OUT High Density D-sub 15 pin ; (female) -
PS IN 4 pin (+, - ) -
ALM output (Form-c) D-sub 25 pin ; female -
Service channel D-sub 37 pin; female ITU-T G.712 (VF), V11 (DSC)
LCT RJ45 RS-232C
PNMS port RJ45 V11, Ethernet (10 Base-T)
PNMT port RJ45 RS-232C
6.3 Service Channels (Please see 4.2 Service Channel for available
channels)
1) DSC/ASC (VF)
E1 DS1
Bit rate 2.048 Mbps +/-50 ppm 1.544 Mbps +/-130 ppm
Input/output level 2.37 Vo-p / 75 ohms 3.0 Vo-p / 100 ohms
3.0 Vo-p / 120 ohms
Impedance 75 ohms unbalance 100 ohms balance
120 ohms balance
Code format HDB-3 B8ZS or AMI
3) EOW
4) Cluster ALM
- 23 -
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005
6.4 General
1) Power Requirement
2) Power Consumption
1+0: 1+1:
6 8 GHz 75 W 150 W
11 38 GHz 55 W 110 W
(typical) (typical)
3) Temperature Range
4) Relative humidity
5) Altitude
Up to 4,000 m
- 24 -
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM
7) Mechanical Dimension
6.6 Indication
1+0 Equipment
LED indication Condition Color
- 25 -
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005
1+1 Equipment
Note: The same fails of No.1/No.2 indicate IDU ALM1 and IDU ALM2 at the same time.
TX1/2 and RX1/2 indication available only in case of 1+1 IDU.
Data In/Data Out (DI/DO) for house keeping alarms or controls are available with LCT setting.
DI/DO item number is changeable by setting LCT configuration.
DI DO Comments
Port condition
DI INPUT Logic : Normal OPEN (> 200 kohms) DO OUTPUT logic : Controlled from PNMS/T
Event CLOSE (< 50 ohms) Interface circuit : Relay Form C
Interface circuit : Photo coupler with bias circuit Maximum Current : 0.2 A
OUTPUT Device : Indicates Status on PNMS/T Maximum Voltage : 100 V (AC + DC)
+3.3 V +3.3 V
Relay
Event Open
. Event Close
Open
Close COM
Event Close
- 26 -
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM
- 27 -
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005
Control Item
IF Loop Back
Baseband Loop Back (near end)
Base band Loop Back (far end)
Modulation off (CW control)
TX Power mute
TX/RX compulsive switching
- 28 -
MTD-PL-032/1401005 NEC Coporation, Tokyo, Japan