You are on page 1of 34

2002 NEC Corporation MTD-PL-028

141005

+
PASOLINK
6-38 GHz 155 MB DIGITAL RADIO SYSTEM
(1 + 0 / 1 + 1 SYSTEM)

This document describes the current version of NEC standard equipment. If


there is any conflict between this document and the System Description and/or
the Compliance statement, the latter will supersede this document.
The specifications or configuration contained in this document are subject to
change without notice due to NEC's continuing design improvement.

NEC Corporation
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM

TABLE OF CONTENTS
LIST OF ABBREVIATIONS..............................................................ii
1. INTRODUCTION ............................................................................................................... 1
2. FEATURES......................................................................................................................... 3
2.1 Advanced Technologies and Superb Performance ........................................................ 3
2.2 High System Gain............................................................................................................ 3
2.3 Easy and Quick Installation ............................................................................................. 3
2.4 Common platform architecture ....................................................................................... 3
2.5 Frequency Agility and Easy Tuning ................................................................................. 3
2.6 TX Power Control ............................................................................................................ 3
2.7 System Flexibility ............................................................................................................. 3
2.8 Maintenance Facilities ..................................................................................................... 4
2.9 Service Channels (Please see 4.2 Service Channel for available channel)................... 4
2.10 Electromagnetic Compatibility (EMC).......................................................................... 4
2.11 Conformity with the ITU................................................................................................ 4
3. RELIABILITY AND QUALITY............................................................................................ 7
4. INTERFACE........................................................................................................................ 9
4.1 Digital Signal Interface..................................................................................................... 9
4.2 Service Channel (SC).................................................................................................... 10
4.3 RF Port .......................................................................................................................... 10
4.4 Alarm Signal Interface.................................................................................................... 10
5. DESIGN CONSIDERATIONS ......................................................................................... 11
5.1 Protection Capability...................................................................................................... 11
5.2 Antenna.......................................................................................................................... 11
5.3 Transmitter-Receiver (ODU) ......................................................................................... 11
5.4 Indoor Unit (IDU) ............................................................................................................ 12
5.5 Other Tools and Materials ............................................................................................. 13
5.6 Option Panel .................................................................................................................. 14
6. PERFORMANCE.............................................................................................................. 21
6.1 Performance.................................................................................................................. 21
6.2 IDU................................................................................................................................. 23
6.3 Service Channels (Please see 4.2 Service Channel for available channels).............. 23
6.4 General .......................................................................................................................... 24
6.5 Events ............................................................................................................................ 25
6.6 Indication........................................................................................................................ 25
6.7 House Keeping Alarm/Control Interface........................................................................ 26
6.8 Alarm Items.................................................................................................................... 27
6.9 Performance Monitoring/Metering Items........................................................................ 28

- i-
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005

LIST OF ABBREVIATIONS
AMI Alternate Mark Inversion Ethernet LAN specification along
IEEE802.3
ANT Antenna
FEC Forward Error Correction
APC Automatic Phase Control
FIL Filter
ATPC Automatic Transmitter
Power Control FOTS Fiber Optical Transport
System
ATT Attenuator
HDB3 High Density Bipolar order 3
B8ZS Binary 8-Zero Substitution
HIC Hybrid Integrated Circuit
BACK-
Pressure Anti-congestion control HYB Hybrid

BB Base Band IDU Indoor Unit

BBE Background Block Error IEC International


Electrotechnical Comission
BER Bit Error Rate
IF Intermediate Frequency
BER-M Bit Error Rate Measuring
INS Insertion
CBL Cable
INTFC Interface
CKT Circuit
ITU-R Radio Communication
CMI Coded Mark Inversion Sector of ITU

ITU-T Telecommunication Sector


CN Carrier to Noise
of ITU
CONV Converter
LCT Local Craft Terminal
CTRL Control
LDC Laser Diode Current
DEM Demodulator
LO Local Oscillator
DI Data Input
LOF Loss of Frame
DO Data Output
LOS Loss of Signal
DPU Digital Processor Unit
MAINT Maintenance
DSC Digital Service Channel
MIC Microwave Integrated Circuit
EMC Electromagnetic
MLC Multi-level Coding
Compatibility
MLCM Multi-level Code Modulation
EOW Engineering Order Wire
Technique
ES Errored Seconds

- ii -
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM

MMIC Monolithic Microwave R-BER Residual Bit Error Rate


Integrated Circuit
RF Radio Frequency
MOD Modulator
RFCOH Radio Frame
MODEM Modulator Demodulator Complementary Overhead

MTPC Manual Transmitter Power RMT Remote


Control
RS Reed Solomon coding
MUX Multiplexer
RSL Received Signal Level
NE Network Element
RSOH Regenerator Section Overhead
OC Over Current
RX Receiver
ODU Outdoor Unit
SC Service Channel
OFS Out of Frame Seconds
SDH Synchronous Digital
OH EXT Overhead Extension Hierarchy

OPT Optical SES Severely Errored Seconds

OW Order Wire STM Synchronous Transport


Module
PBR Parity Bit Error Rate
T-R Transmitter Receiver
PM CARD PASOLINK Management
Card TX Transmitter

ppm parts per million UAS Unavailable Seconds

PS Power Supply VF Voice Frequency

PWR Power WS Wayside

QAM Quadrature Amplitude


Modulation

- iii -
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005

This page is intentionally blank.

- iv -
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM

1. INTRODUCTION

+
NECs new PASOLINK series; 6-38 GHz 155 Mbps Synchronous Digital Hierarchy (SDH)
microwave radio systems are designed to transmit one synchronous transport module (STM-
1, 155 Mbps). They operate at the 6-38 GHz radio frequency band using quadrature amplitude
modulation (32-QAM or 128-QAM), and have a transmission capacity of OC3 or STM-1. In
+
addition to the PASOLINK systems for short distance links, NEC offers a complete product
line of STM-1 radio systems that includes the 4, L6, 7, 8, 13 GHz 155 Mbps 128 QAM and 4,
5, U6, 8, 11 GHz 155 Mbps 64 QAM systems for long distance use. For those systems,
please refer to the other technical descriptions.

+
The PASOLINK radio systems are fully compatible with SDH Network Elements (NE). The
systems consist of antennas, outdoor units (ODU), and indoor units (IDU). They are
connected through a coaxial cable for each radio channel. Available configurations are non-
protection type (1 + 0) and protection type (1 + 1). The protection type is available for twin-
path type and hot-standby type.

Regarding antenna configurations there are two types available. There is a one-antenna
system employing hybrid (HYB) RF combiner and divider, and a two-antenna system method
using each antenna for two ODUs independently. The hybrid is the passive device that
combines and divides the signals between two ODUs and an antenna. Therefore, the one-
antenna system requires only a single antenna, however, additional loss between ODUs and
antenna have to be considered. On the other hand, the two-antenna system has high system
gain as same as non-protection type.

+
STM-1 interface can be selected for electrical or optical. Therefore, PASOLINK systems are
useful in fiber optical transport system (FOTS). Additionally, Fast Ethernet interface can be
selected for IP network.

+
The PASOLINK employs a full digital MODEM using enhanced signal processing techniques
and forward error correction (FEC). Moreover, the bit-error-rate characteristics against
receiver input signals are excellent for applying FEC (32-QAM System: MLCM (multi-level
code modulation) and RS (Reed Solomon method), 128-QAM System : QAM and RS).

The equipment can be installed easily and quickly using a PC (as Local Craft Terminal), and
as a maintenance tool.

-1-
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005

Type 1 Type 2
11-38 GHz 128 QAM/32 QAM type 6-8 GHz 128 QAM type
(0.3m Diameter Antenna) (Low Loss Coaxial cable connection to Antenna)

Figure 1. Antenna and (1 + 0) ODU

Figure 2-1. Indoor Unit (IDU) 1 + 0 Configuration

Figure 2-2. Indoor Unit (IDU) 1 + 1 Configuration

-2-
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM

2. FEATURES

2.1 Advanced Technologies and Superb Performance


Throughout the SDH radio system, NECs own advanced technologies are used. Intensive
use of Microwave Integrated Circuits (MICs) and Hybrid ICs (HICs) make the TRP durable
and compact. Also, custom made large-scale integrated circuits (LSIs) are applied. For
example, a new digital MODEM is incorporated in a single LSI chip, specially developed by
NEC for the radio equipment. Furthermore, low-power high-speed complementary metal
oxide semiconductor (CMOS) LSIs are extensively used, making the equipment more
compact and reducing the power consumption.

2.2 High System Gain


Multi-Level Coding Modulation (MLCM) is applied to ensure a better error performance (32
QAM System).
Forward Error Correction (FEC) with Reed-Solomon coding is equipped to improve BER
performance.

2.3 Easy and Quick Installation


Interconnection: Only one coaxial cable and automatic equalization (up to 450 m by using
12D-FB cable)
Compact and Light
Various mounting methods for IDU, ODU, and antenna

2.4 Common platform architecture


The ODU of 128 QAM type can be used for 32 QAM type.

2.5 Frequency Agility and Easy Tuning


Field tunable local-oscillator (Synthesizer)
RF point frequency can be changed through LCT (Local Craft Terminal, except 6 8 GHz)
Frequency Tunable without changing RF FIL on Subband basis.

2.6 TX Power Control


ATPC (Automatic Transmitter Power Control) reduces interference to neighboring
systems, improves residual BER performance, alleviates upfade problems. The adjustable
range of ATPC is -20 dB to 0 dB (128-QAM) and 23 dB to 0 dB (32-QAM).
MTPC (Manual Transmitter Power Control) is also available through LCT. The adjustable
range of MTPC is 20 dB to 0 dB (128-QAM) and 23 dB to 0 dB (32-QAM) at 1 dB step.

2.7 System Flexibility


(1 + 0) Unprotected
(1 + 1) Hot-standby
(1 + 1) Hot-standby with Space Diversity
(1 + 1) Twin-path (Hitless switching)
IDU is commonly used for all frequency bands.

(In case of 1+1 Hot-standby or twin-path system, either one antenna system with hybrid
combiner or two antenna system excluding hybrid combiner is chosen. Please refer to Fig. 3
(a), (b).)
1 + 1 Hybrid combiner: NEC provides 3 dB balance-type hybrid combiner.

-3-
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005

2.8 Maintenance Facilities


-4 -5
Pre-settable BER alarm point: 10 , 10 , 10
-6

IF, Baseband (near end, far end) loop back (without external equipment)
Remote monitoring of ODU operating condition on IDU
Calling facility between IDUs

2.9 Service Channels (Please see 4.2 Service Channel for available channel)
Order Wire : IDU-IDU/IDU-ODU/ODU-ODU party line connection
(EOW) (EOW system using PASOLINK MONITOR (option) at ODU)
Digital Port : 64 kbps Sync., 2 ch standard
VF Port : 0.3 to 3.4 kHz (1 ch) 600 ohms, 2 ch standard
Wayside : 2.048/1.544 Mbps, 1 ch (optional at 32 QAM STM-1)
10 Base-T : 1 ch (optional; exclusive use in other service channels)
Cluster Alarm : 2 ch (optional; auxiliary alarm transmission)

2.10 Electromagnetic Compatibility (EMC)


Complies to ETS 300385

2.11 Conformity with the ITU


Conformity with the relevant ITU-R, ITU-T Recommendations and European
Telecommunication Standard (ETSI)

ODU 1
HYBRID

ODU 2
ANTENNA

+
Figure 3(a). Ways to Mount the 1 + 1 PASOLINK using a single Antenna

-4-
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM

+
Figure 3(b). Ways to Mount the 1 + 1 PASOLINK using two Antennas

-5-
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005

This page is intentionally blank.

-6-
+
MTD-PL-028/1401005 PASOLINK 155 MB 1+0/1+1 SYSTEM

3. RELIABILITY AND QUALITY

+
NECs PASOLINK utilizes advanced VLSI, MIC and MMIC technology for all-solid-state
circuitry from data input to RF output.

NEC plants are located all over the world, and quality control is carefully monitored in every
manufacturing step, such as parts selection, assembly, adjustment and testing. NEC Quality
Controls employing Zero Defect and Value Engineering Techniques extend to every aspect of
production and inspection in accordance with stringent Total Quality Control programs. In
addition, NEC plants have obtained ISO 9001 certifications.

-7-
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005

This page is intentionally blank.

-8-
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM

4. INTERFACE
+
The NEC PASOLINK system has the ITU-T standard interface conditions as listed below:

4.1 Digital Signal Interface

1) Main, Traffic, Electrical (STM-1) [Selectable]

Type (ITU-T G.703) : In station section, full functionality


Bit Rate : 155.520 Mbit/s 20 ppm
Level : 1 Vp-p (nominal)
TX accepts 12.7 dB cable loss at 78 MHz
Code Format : CMI
Impedance : 75 ohms, unbalanced (nominal)
Connector : IEC 169-13

2) Main Traffic, Optical (STM-1) [Selectable]

Type (ITU-T G.957) : S-1.1 (Inter-Office)


Bit Rate : 155.52 Mbit/s 20 ppm
Level : S-1.1 -8 to -15 dBm (transmit level)
-8 to -28 dBm (receive level)
Connector : FC/PC

3) Main Traffic, Optical mono fiber (STM-1) [Selectable]

Bit Rate : 155.520 Mbit/s 20 ppm


Transmit Wavelength : A type = 1310 nm
: B type = 1550 nm
Receive Wavelength : A type = 1550 nm
: B type = 1310 nm
Mean Optical Output Power : -7 dBm (typ.)
Minimum Receive Overload Power : -3 dBm
Minimum Receive Sensitivity : -23 dBm
Connector : FC/PC

4) SOH Termination

l SOH Termination : RST


(Full transparent transmission for SOH at default setting.)
(E1 and F1 byte can be used for DSC.)

5) Main Traffic, Ethernet (10/100 Base-T(X)) [Selectable]

Type : 10 Base-T/100 Base-TX (Auto-sensing or fixed)


Port Number and Interface : 2 (Each port is separated), RJ45
Transmission Rate (Port 1 + Port 2) : 100 Mbps + 50 Mbps, 75 Mbps + 75 Mbps or
2 ch. best effort selectable
Flow control : Full Duplex or Half Duprex (Backpressure)/
Auto negotiation

-9-
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005

Forwarding Mode : Store-and-Forwarding


(This interface card is worked as Ehernet
Bridge.) (This interface card is compliant with
IEEE802.3.)

4.2 Service Channel (SC)

32 QAM STM-1 128 QAM STM-1 Connector

Order wire (Voice) 1 ch 1 ch Head set receptacle

DSC 64 Kbps Sync. V.11 2 ch standard 2 ch standard D-sub 37 pin


contra/co-directional selectable

ASC (0.3-3.4 kHz) 4W 2 ch standard 2 ch standard D-sub 37 pin


600 ohms

Wayside 2.048 Mbps/1.544 Mbps*1 1 ch optional N/A D-sub 9 pin


(G.703)

10 Base-T *1 2 Mbps 1 ch optional 64 kbps 1 ch optional*2 RJ45

Cluster ALM 2 ch optional 2 ch optional D-sub 15 pin

*1: Wayside and 10 Base-T are used exclusively each other.


*2: This option needs one channel of DSC or ASC.

4.3 RF Port

Interface

Coaxial : 6-8 GHz SMA Coaxial connector


(N type optional)
Waveguide : 11 GHz waveguide PDR 100
: 13-15 GHz waveguide PBR 140
: 18-23 GHz waveguide PBR 220
: 26 GHz waveguide PBR 260
: 38 GHz waveguide PBR 320
Antenna direct mount : 11-38 GHz NEC original interface

Polarization : Vertical or Horizontal (field changeable)


(waveguide type)

4.4 Alarm Signal Interface

Interface : Relay Contact (Form-C)


Connector : 25-way D-sub

- 10 -
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM

5. DESIGN CONSIDERATIONS

5.1 Protection Capability

+
PASOLINK provides a protection switching system of Hot-standby protection (1 + 1), and
twin-path protection (1 + 1).

1. Non-Protection System

Non-protection system consists of one ODU, one IDU for 1 + 0 System, and one antenna.

2. Hot-Standby System

Hot-Standby system consists of two ODUs, one IDU for 1 + 1 system, and one or two sets of
antennas. The protection switch of this systems is performed by the TX switches on the
ODUs at the transmitting end and Hitless switch on the 150 M INTFC (or OPT INTFC) module
in the IDU at the receiving end.

3. Twin-path System

Twin-Path system consists of two ODUs, one IDU for 1 + 1 System, and two sets of
antennas. The protection switch of this system is performed by the Hitless switch on the 150
M INTFC (or OPT INTFC) module in the IDU at the receiving end.

5.2 Antenna

+
The complete menu of PASOLINK antennas includes diameters of 0.3m to 1.8m. They are
designed to meet stringent requirements on mechanical rigidity. Antennas with diameters of
0.3m to 1.8m can be mounted directly to the ODU, making waveguides obsolete. This has
relevant cost and reliability merits and makes the installation quicker and easier. The
+
PASOLINK pole mounting structure is designed in a way that the ODU can be replaced while
keeping the antenna and mounting bracket, including orientation, in place. The reflectors of the
antennas are covered with white diffusive paint and the mounting structure is hot-dip
galvanized.
In the 6 - 8 GHz band, coaxial or waveguide cable with transducer is used for connecting
between the ODU and IDU.

5.3 Transmitter-Receiver (ODU)

A block diagram is shown in Figure 4-5.

The transmitter-receiver is designed to handle a STM-1 signal in 6-38 GHz bands. The
equipment is designed to withstand severe weather conditions.
32/128-Quadrature amplitude modulation (32/128 QAM) is applied.

Local Oscillator is employed for APC (Automatic Phase Control) loop circuit at the transmitter
and receiver.

- 11 -
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005

5.4 Indoor Unit (IDU)

The IDU consists of six (6) panels that have following functions. (Figure 4-1)

1. ODU INTFC

Performing the multiplexing/demultiplexing of the transmitting signal, receiving signal, SV and


EOW signal

Compensating the signal loss depending on IF cable length


Automatic Gain control

2. 32 QAM MODEM / 128 QAM MODEM

32/128 QAM (Quadrature Amplitude Modulation), Modulator/Demodulator


Compensating quality degradation caused by fading
Error correction of burst error using the Reed Solomon encoding/decoding
MLC (Multi Level Code) encoding/decoding. (Only for 32-AM)
Data streams conversion depending on the modulation scheme
Scrambling/de-scrambling of the data
RFCOH multiplexing/demultiplexing
Velocity conversion for radio frame

3. 150M INTFC / OPT INTFC / 10/100 BASE-T(X) INTFC (Selectable)

STM-1 signal interface (150M INTFC / OPT INTFC)


RSOH multiplexing/demultiplexing (150M INTFC / OPT INTFC)
Hitless switching of No.1 and No.2 receiving signal (150M INTFC / OPT INTFC)
2 ports 10 BASE-T/100 BASE-TX INTFC (Each port traffic is separated) (10/100 Base-
T(X))
Transparency for VLAN (IEEE 802.1Q Tagged frame) (10/100 Base-T(X))

4. CTRL

Setting of equipment operation


Monitoring alarm status of the equipment
Performing performance monitoring
Providing upper rank NMS interface
LCT terminal interface
EOW interface

5. WS INTFC (option) (32-QAM option)

Interface of 2048/1544 kbps Wayside signal

6. LAN CARD (Option)

Ethernet interface (10 Base-T) card with bridge function (exclusive use against WS
interface)

- 12 -
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM

7. DC-DC CONV

Converting 48 VDC (option 24 VDC) input voltage to several internal utilizing voltages

5.5 Other Tools and Materials

1. LCT

Local Craft Terminal (LCT) is the simple provisioning and maintenance terminal for
+
PASOLINK system. LCT connects to the IDU. The LCT can control all functions and
measures all monitor levels.

2. PNMS

NEC can provide an Element Network Management tool (PNMS: PASOLINK Network
Management System). These tools can be used for maintenance and performance

monitoring. These tools consist of software for UNIX or WINDOWS NT OS.

3. Coaxial Cable (Interconnection between IDU and ODU)

The 5D-FB, 8D-FB, 10D-FB or 12D-FB coaxial cable (Low loss 50 ohms) serves as the
interconnection between the transmitter-receiver (ODU) and baseband unit (IDU). The cable
exchanges I/O data signals, DC power, alarm signals, control signals for frequency and TX
power, RX level and ODU primary voltage monitoring signals and a pair of orderwire signals.
Due to the use of different IF (Intermediate Frequency) for TX and RX, a single coaxial cable is
sufficient. This results in faster and easier installation.

4. Power Supply Voltage

The nominal power supply voltage is 48 VDC. The guaranteed range of the same unit is
sufficient for nominal voltage of 36 to 60 V (48 V) as well. In this way, commonality
between modules is achieved throughout the network even if different DC voltages are applied
at different locations. (24 VDC power supply is available as an option.)

5. PASOLINK MONITOR (OPTION)

PASOLINK MONITOR is used for receiving signal level monitor and ODU-IDU/ODU-ODU
EOW system. This is an installation tool for antenna direction pointing. (Receiving level can
be measured as voltage by voltmeter without PASOLINK MONITOR.)

6. Head set

Head set is used for EOW system.

- 13 -
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005

5.6 Option Panel

Option panel list

Slot Panel
1 STM-1e Electric Interface
2 STM-1/OC3 Optical Interface (S-1.1)
3 Main slot STM-1/OC3 Optical Interface (WDM Monofiber TX:1.3um RX:1.5um)
4 STM-1/OC3 Optical Interface (WDM Monofiber TX:1.5um RX:1.3um)
5 Ethernet 10 Base-T/100 Base-TX (2ch)
A Wayside 2.048 Mbps 75 ohms balance
B Wayside 2.048 Mbps 120 ohms unbalance
C Wayside 1.544 Mbps 110 ohms unbalance
D Wayside 2.048 Mbps 75 ohms balance + Cluster ALM
E Side slot Wayside 2.048 Mbps 120 ohms unbalance + Cluster ALM
F Wayside 1.544 Mbps 110 ohms unbalance + Cluster ALM
G Cluster ALM
H Ethernet 10 Base-T (2 Mbps (wayside) or 64 Kbps) (1 ch)
I Blank panel

- 14 -
MTD-PL-028/141005

ANT ANT

IDU ODU ODU IDU

DC-DC DC-DC DC-DC DC-DC


2x CONV CONV CONV 2x
CONV
10/100Base-T(X) *2 10/100Base-T(X)
*2
10/100Base-T(X)
10/100Base-T(X)

*2 *2
STM-1 ODU 150M INTFC/
150M INTFC/ ODU MODEM STM-1
IN/OUT OPT INTFC MODEM INTFC INTFC OPT INTFC
RF RF IN/OUT
CKT CKT
PNMS PNMS
CTRL CTRL
LCT LCT

+
*1 *1
LO CTRL CTRL LO *1 *1
WS IN/ WS INTFC WS INTFC WS IN/
OUT OUT

*1

- 15 -
*1
10Base-T LAN CARD LAN CARD 10Base-T

*1 WS INTFC or LAN CARD is used exclusively.


*2 150M INTFC/OPT INTFC or 10/100Base-T(X) INTFC is used exclusively.

150M INTFC : Electrical STM-1 Interface LO : Local Oscillator RF CKT : Radio Frequency Circuit
ANT : Antenna MODEM : Modulator-Demodulator STM-1 : Synchronous Transport Module-1
CTRL : Control OPT INTFC : Optical STM-1 Interface WS INTFC : Wayside Interface (optional)
+

Figure 4-1. PASOLINK - 1 + 0 System Block Diagram


DC-DC CONV : DC-DC Converter ODU : TRP-( )G150MB5-2-
IDU : MDP-150MB5T-2- OW : Orderwire
PASOLINK 155 MB 1+0/1+1 SYSTEM
+

IDU ODU(No.1 CH) ODU(No.1 CH) IDU

SW UNIT MD UNIT MD UNIT SW UNIT


DC-DC DC-DC DC-DC DC-DC
2x CONV 2x
CONV CONV CONV
10/100Base-T(X) 10/100Base- T(X)
*2 *2
10/100Base-T(X)
10/100Base-T(X)

ODU ODU 150M INTFC/ STM-1


STM-1 150M INTFC/ MODEM MODEM
OPT INTFC INTFC RF RF INTFC OPT INTFC IN/OUT
IN/OUT *2
*2 CKT CKT

10/100 Base-T
PASOLINK 155 MB 1+0/1+1 SYSTEM

LO CTRL CTRL LO PNMS


PNMS CTRL
CTRL ANT ANT
LCT
LCT

OW IN/OUT OW IN/OUT

+
MD UNIT ODU(No.2 CH) ODU(No.2 CH) MD UNIT

DC-DC DC-DC DC-DC DC-DC

- 16 -
CONV CONV CONV CONV
*1 *1

WS IN/ ODU ODU WS IN/


WS INTFC MODEM MODEM WS INTFC
OUT INTFC INTFC OUT
RF RF
CKT CKT
*1 *1

10Base-T LAN CARD LAN CARD 10Base-T

LO CTRL CTRL LO

OW IN/OUT OW IN/OUT

*1 WS INTFC or LAN CARD is used exclusively.


*2 150M INTFC/OPT INTFC or 10/100Base-T(X) INTFC is used exclusively.

Figure 4-2. PASOLINK - Hot-standby System Block Diagram


150M INTFC : Electrical STM-1 Interface LO : Local Oscillator RF CKT : Radio Frequency Circuit
ANT : Antenna MODEM : Modulator-Demodulator STM-1 : Synchronous Transport Module-1
CTRL : Control OPT INTFC : Optical STM-1 Interface WS INTFC : Wayside Interface (optional)
DC-DC CONV : DC-DC Converter ODU : TRP-( )G150MB5-2-
IDU : MDP-150MB5T-2- OW : Orderwire
MTD-PL-028/141005
ANT ANT

IDU ODU(No.1 CH) ODU(No.1 CH) IDU

SW UNIT MD UNIT MD UNIT SW UNIT


DC-DC DC-DC DC-DC DC-DC
2x 2x
MTD-PL-028/141005

CONV CONV CONV CONV


10/100Base-T(X) 10/100Base-T(X)
*2 *2
10/100Base-T(X) 10/100Base- T(X)

STM-1
IN/OUT 150M INTFC/ ODU RF RF ODU 150M INTFC/ STM-1
MODEM MODEM
OPT INTFC INTFC CKT CKT INTFC OPT INTFC IN/OUT
*2 *2

PNMS LO CTRL CTRL LO PNMS


CTRL CTRL
LCT LCT

OW IN/OUT OW IN/OUT

+
ANT ANT 10/100Base-T(X)

MD UNIT ODU(No.2 CH) ODU(No.2 CH) MD UNIT

DC-DC DC-DC DC-DC DC-DC


CONV CONV CONV CONV

- 17 -
*1
*1
WS IN/ ODU ODU
WS INTFC MODEM MODEM WS IN/
OUT INTFC INTFC WS INTFC
RF RF 10/100Base-T(X) OUT
CKT CKT

*1 *1

10Base-T LAN CARD LAN CARD 10Base-T


LO CTRL CTRL LO

OW IN/OUT OW IN/OUT
+

*1 WS INTFC or LAN CARD is used exclusively.


*2 150M INTFC/OPT INTFC or 10/100Base-T(X) INTFC is used exclusively.

Figure 4-3. PASOLINK - 1 + 1 Twin-path System Block Diagram


150M INTFC : Electrical STM-1 Interface LO : Local Oscillator RF CKT : Radio Frequency Circuit
ANT : Antenna MODEM : Modulator-Demodulator STM-1 : Synchronous Transport Module-1
CTRL : Control ODU : TRP( )G150MB5-2- WS INTFC : Wayside Interface (optional)
DC-DC CONV : DC-DC Converter OPT INTFC : Optical STM-1 Interface
IDU : MDP-150MB5T-2- OW : Orderwire
PASOLINK 155 MB 1+0/1+1 SYSTEM
ANT ANT

IDU ODU(No.1 CH) ODU(No.1 CH) IDU

SW UNIT MD UNIT MD UNIT SW UNIT


+

2x DC-DC DC-DC DC-DC DC-DC 2x


10/100Base-T(X) CONV CONV CONV CONV 10/100Base- T(X)
*2 *2
10/100Base-T(X) 10/100Base-T(X)

STM-1 150M INTFC/ ODU RF RF ODU 150M INTFC/ STM-1


MODEM MODEM
IN/OUT OPT INTFC INTFC CKT CKT INTFC OPT INTFC IN/OUT
*2 *2

PNMS LO CTRL CTRL LO PNMS


CTRL CTRL
PASOLINK 155 MB 1+0/1+1 SYSTEM

LCT LCT

+
OW IN/OUT OW IN/OUT

ANT ANT

MD UNIT ODU(No.2 CH) ODU(No.2 CH) MD UNIT

DC-DC DC-DC DC-DC DC-DC


CONV CONV CONV CONV

*1 *1

WS IN/ ODU ODU WS IN/


WS INTFC MODEM MODEM WS INTFC

- 18 -
OUT INTFC INTFC
RF RF OUT
CKT CKT
*1 *1

10Base-T LAN CARD LAN CARD 10Base-T

LO CTRL CTRL LO

OW IN/OUT OW IN/OUT

*1 WS INTFC or LAN CARD is used exclusively.


*2 150M INTFC/OPT INTFC or 10/100Base-T(X) INTFC is used exclusively.

150M INTFC : Electrical STM-1 Interface LO : Local Oscillator RF CKT : Radio Frequency Circuit
ANT : Antenna MODEM : Modulator-Demodulator STM-1 : Synchronous Transport Module-1
CTRL : Control ODU : TRP( )G150MB5-2- WS INTFC : Wayside Interface (optional)
DC-DC CONV : DC-DC Converter OPT INTFC : Optical STM-1 Interface
IDU : MDP-150MB5T-2- OW : Orderwire

Figure 4-4 PASOLINK - Hot-standby / Space Diversity System Block Diagram


MTD-PL-028/141005
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM

TX first MIX
(Depend on frequency band)
RF CKT

TX IF MIX BPF MIX BPF PA


TX IF

DUP
MPX
to/from to/from
IDU ANTENNA
RX IF BPF MIX

LNA

DC-DC CONV LO CTRL

+
Figure 4-5. PASOLINK - ODU Block Diagram

(a) 1+0 ODU (Type 2)

(b) 1+0 IDU


Figure 5. External View of ODU and IDU

- 19 -
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005

Figure 6. Interconnection of ODU and IDU (1 + 0)

- 20 -
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM

6. PERFORMANCE

6.1 Performance

STM-1/OC3 Narrow band STM-1/OC3


Modulation 32 QAM 128 QAM
Forward Error Correction Reed-Solomon and Multi-level Reed-Solomon Coding
Coding
CH Spacing 55(56) MHz 27.5 (28) MHz
Data Interface Electrical/Optical
ATPC + MTPC Range -23 to 0 dB -20 to 0 dB
Additional Attenuation 5 dB for span equalization (except 38 GHz)
(All other values are typical except indicated as guaranteed values).
Frequency 6/7/8 11 GHz 13 GHz 15 GHz 18 GHz 23 GHz 26 GHz 38 GHz
band GHz

Range 5.9 8.5 10.7 11.7 12.75 13.25 14.25 15.35 17.7 19.7 21.2 23.6 24.25 27.0 37.0 40.0
(GHz)
TX Output Power (dBm) 6/7/8 GHz, 11/13/15 GHz : Guarantee Value : 2 .0 dB
18 GHz : Guarantee Value : +2.0, -1.0 dB
23/26 GHz : Guarantee Value : 2.0 dB
38 GHz : Guarantee Value : 3.0 dB
STM-1 - - - - 18 18 17 13.5
STM-1 25 16.5 16.5 16.5 15 15 14 10.5
(N.B)
STM-1 - - 18 18 19 19 18 14.5
(NB), High
power ver.
(optional)
Receiver Threshold (dBm) at 10-6 BER (Guarantee Value : +3dB)
STM-1 - - - - -76 -76 -75.5 -74
STM-1 -68 -67 -67 -67.5 -67.5 -67.5 -67 -66
(N.B)
at 10 -3 Above value -1 dB
BER
System Gain (dB) at 10-6 BER (*1) (Guarantee Value : -3dB)
STM-1 - - - - 94 94 92.5 87.5
STM-1 93 83.5 83.5 84 82.5 82.5 81 76.5
(N.B)
STM-1 - - 85 85.5 86.5 86.5 85 80.5
(NB), High
power ver.
(optional)
at 10 -3 Above value + 1 dB
BER
Frequency +/-6 ppm (+/- 0.0006%) (Typical), +/-10 ppm (+/- 0.001%) (Guarantee)
Stability
Tuning Center- Up to 50 MHz Up to 370 MHz (Depend on T-R spacing)
Bandwidth tuned (Depend on T-R spacing)
N.B: Narrow band
*1. In case of using a NEC BR CKT for 1 + 1 Hot-standby configuration, additional loss of 7 dB (typical) will be
considered.

STM-1 (128 QAM)/(32 QAM)


WS Signal OPTION: (32 QAM only) See 4.2
Digital Service See 4.2
Channel
Analog Service See 4.2
Channel (VF)
House Keeping Inputs 6 photo-coupler
Alarms Outputs: 4 Form-C dry contact relays
Network Management NMS Protocol: SNMP
Interface: 10 Base-T or V.11

- 21 -
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005

STM-1 (128 QAM)/(32 QAM)


Power Supply Voltage 36 to 60V (EN60950) (24V: OPTION)
Power Consumption See 6.4
Ambient Temperature IDU : -5C to +50C
ODU: -33C to +50C

STM-1/OC3 Narrow band STM-1/OC3


SOH terminal RST mode
IDU size 1+0: 1U
1+1: 3U
BB Interface STM-1e
OC3/STM-1 (S-1.1)
10 Base-T/100 Base-TX
WS (2 Mbps or 1.5 Mbps) 1 CH (E1, T1) -
(optional)
WS/DSC 10 Base-T Interface 10 Base-T 10 Base-T
(optional) (transmission rate 2 Mbps) (transmission rate 64 kbps)
(*exclusive use for WS)
Cluster Alarm 2 ch 2 ch
(optional)
EOW: IDU-IDU Available
EOW: ODU-IDU (PASOLINK MONITOR is used at ODU-ODU, ODU-IDU.)
EOW: ODU-ODU
ODU AGC MONITOR Available
System composition 1+0, 1+1 (HS/Twin Path)
-6 -12
Receiver BB switching Hitless SW (Switching Threshold: 10 to 10 selectable)
Transmitter RF switching Power Mute System
BB Loop Back Near End/Far End, Remote/Local
IF Loop Back Available (Local only)
Frequency setting Setting available from IDU by PNMT, LCT
Transmitter output setting Setting available from IDU by PNMT, LCT
ODU-IDC Cable Max.300 m (8D-FB), 450 m (12D-FB)
PM (Performance Monitor) Conform to G.826
External Alarm IDU ALM
(See 6.7) ODU ALM
MAINT
PS

- 22 -
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM

6.2 IDU

Modulation type 32 MLCM 128 QAM


Symbol frequency 41.51808 MHz 24.236883 MHz
FEC Reed-Solomon Reed-Solomon
MLCM
Transmission capacity 155.52 Mbps (STM-1)
STM-1 interface Electrical G.703
Optical G.957 S-1.1

Interface Connector
Item Physical Electrical
IF signal in/out Type N female -
STM-1 electrical IEC169-13 (1.6/5.6) ITU-T G.703
STM-1 optical FC/PC optical connector ITU-T G.957
Ethernet (MAIN) RJ45 10 Base-T/100 Base-TX
Ethernet (SC/WS) RJ45 10 Base-T
WS D-sub 9 pin ; (female) ITU-T G.703
Cluster ALM IN/OUT High Density D-sub 15 pin ; (female) -
PS IN 4 pin (+, - ) -
ALM output (Form-c) D-sub 25 pin ; female -
Service channel D-sub 37 pin; female ITU-T G.712 (VF), V11 (DSC)
LCT RJ45 RS-232C
PNMS port RJ45 V11, Ethernet (10 Base-T)
PNMT port RJ45 RS-232C

6.3 Service Channels (Please see 4.2 Service Channel for available
channels)
1) DSC/ASC (VF)

DSC (Please see 4.2 Service Channel ASC


regarding available channel)
Type V11 : 64 kbps Sync. (contra/co- Circuit : 4w
directional selectable) Frequency Band : 0.3 - 3.4 kHz
Level : -6 dBm (600 ohms)
nominal

2) Wayside (only in case of 32 QAM) (see 4.2)

E1 or DS1 is set at shipping from factory.

E1 DS1
Bit rate 2.048 Mbps +/-50 ppm 1.544 Mbps +/-130 ppm
Input/output level 2.37 Vo-p / 75 ohms 3.0 Vo-p / 100 ohms
3.0 Vo-p / 120 ohms
Impedance 75 ohms unbalance 100 ohms balance
120 ohms balance
Code format HDB-3 B8ZS or AMI

3) EOW

EOW : ODU-IDU/IDU-IDU/ODU-ODU party line connection with head set


(PASOLINK MONITOR (optional) is used at ODU-ODU/ODU-IDU.)

4) Cluster ALM

Auxiliary alarm transmission

- 23 -
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005

6.4 General
1) Power Requirement

Type 1 48VDC (36V to 60V)


Type 2 24VDC (20V to 60V (option))

2) Power Consumption

1+0: 1+1:
6 8 GHz 75 W 150 W
11 38 GHz 55 W 110 W
(typical) (typical)

3) Temperature Range

Guaranteed operation IDU : -5C to +50C


ODU : -33C to +50C
Workable operation IDU : -10C to +55C
ODU : -40C to +55C
Transport and storage IDU : -40C to +70C
ODU : -40C to +70C

4) Relative humidity

IDU : Less than 90% at 50C (Non-condensing)


ODU : 100% applicable

5) Altitude

Up to 4,000 m

6) Interconnection between ODU and IDU


Interconnection : Single coaxial cable/Impedance = 50 ohms
Type of cable : 5D-FB, 8D-FB, 10D-FB, 12D-FB or Equivalent cable
Signals : IF signal, alarms control, monitoring
power source, and, orderwire

Maximum cable length* : 150 m (5D-FB)


300 m (8D-FB)
350 m (10D-FB)
450 m (12D-FB)
Cable equalization : Automatic level equalization
Note* : In case of hitless protection, set each length of two IF cables to same and not to
exceed 100 meters.

- 24 -
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM

7) Mechanical Dimension

ODU : 240(W) x 243(H) x 124(D) : Approx. 5 Kg (Type 1)

: 260(W) x 410(H) x 190(D) : Approx. 10 Kg (Type 2)

IDU 1+0 : 482(W) x 44(H) x 292(D) : Approx. 5 Kg*


1+1 : 482(W) x 133(H) x 300(D) : Approx. 13 Kg*
Note*: Including option panel
Note : Salt damage
In case of operating in the sea or around the coast area (within 3 km from coastline),
measure must be taken for the ODU against salt damage. Please ask NEC for
countermeasure.
6.5 Events

Alarm Events for 1+0 system


Event Event conditions ALM indication
LED
LOS Input signal lost (Input STM-1 signal) LED on Module panel
LOF Frame synchronization lost (Input STM-1 signal) IDU ALM and LED on Module
panel
INTFC ALM STM-1 interface unit failure, Loss of output STM-1 signal IDU ALM and LED on Module
panel
BER (RX) ALM Excessive BER IDU ALM
BER degraded worse than preset value (10e-3 to 10e-
5)
MOD ALM TX side alarm includes unit failure, IF output signal IDU ALM
degraded.
DEM ALM RX side alarm includes unit failure, IF signal input lost. IDU ALM
WS ALM Unit fail, WS input signal lost. IDU ALM
TX PWR ALM ODU transmitting power decreased ODU ALM
TX IN ALM Receiving TX IF signal level decreased ODU ALM
RX IN ALM Receiving signal level decreased ODU ALM
APC ALM ODU APC loop is out of lock ODU ALM
MAINT ALM LCT set to MAINT status MAINT

6.6 Indication

LED Indication on the equipment front


Failure indication of the equipment unit to be replaced.

1+0 Equipment
LED indication Condition Color

MAINT During Maintenance Yellow

ODU ALM ODU equipment failure Red

IDU ALM IDU equipment failure Red

PWR On power Green

- 25 -
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005

1+1 Equipment

LED indication Condition Color

MAINT During maintenance Yellow

ODU ALM1 ODU No.1 Equipment fail Red

IDU ALM1 IDU No.1 Equipment fail Red

ODU ALM2 ODU No.2 Equipment fail Red

IDU ALM2 IDU No.2 Equipment fail Red

PWR1 No.1: On power Green

PWR2 No.2 : On power Green

TX1 No.1 TX output Green

TX2 No.2 TX output Green

RX1 No.1 RX selected Green

RX2 No.2 RX selected Green

Note: The same fails of No.1/No.2 indicate IDU ALM1 and IDU ALM2 at the same time.
TX1/2 and RX1/2 indication available only in case of 1+1 IDU.

6.7 House Keeping Alarm/Control Interface

Data In/Data Out (DI/DO) for house keeping alarms or controls are available with LCT setting.
DI/DO item number is changeable by setting LCT configuration.

DI DO Comments

6 ports 4 ports (Max) DI : DI interfaces are included in ALM/AUX connector.


DO: Refer to next page alarm output connection table.

Port condition
DI INPUT Logic : Normal OPEN (> 200 kohms) DO OUTPUT logic : Controlled from PNMS/T
Event CLOSE (< 50 ohms) Interface circuit : Relay Form C
Interface circuit : Photo coupler with bias circuit Maximum Current : 0.2 A
OUTPUT Device : Indicates Status on PNMS/T Maximum Voltage : 100 V (AC + DC)

+3.3 V +3.3 V

Relay
Event Open

. Event Close

Open
Close COM

Event Close

- 26 -
+
MTD-PL-028/141005 PASOLINK 155 MB 1+0/1+1 SYSTEM

6.8 Alarm Items


Alarms outputs are available to connect to RL1 to RL11.
Alarm output connection to RL( ) is changeable by LCT.
Event Summarized external alarms (Form-C)
Connector ALM Connector AUX/ALM
RL1 RL2 RL3 RL4 RL5 RL6 RL7 RL8 RL9 RL10 RL11
MAINT - - - - - - - - - -
PS ALM - - - - - - - - - -
CPU ALM - - - - - - - - - -
ODU ALM1 - - -
ODU ALM2 - - -
CBL ALM1 - - -
CBL ALM2 - - -
TX PWR ALM1 - - -
TX PWR ALM2 - - -
TX IN ALM1 - - -
TX IN ALM2 - - -
RX IN ALM1 - - -
RX IN ALM2 - - -
APC ALM1 - - -
APC ALM2 - - -
IDU ALM1 - - -
IDU ALM2 - - -
MOD ALM1 - - -
MOD ALM2 - - -
DEM ALM1 - - -
DEM ALM2 - - -
Sub INTFC - - -
MAIN INTFC - - -
BER ALM1 - - -
BER ALM2 - - -
STM-1 LOS - - -
HK-OUT1 - - - - - - - - - -
HK-OUT2 - - - - - - - - - -
HK-OUT3 - - - - - - - - - -
HK-OUT4 - - - - - - - - - -

Note: marks are set at factory.


marks are range for selection.

- 27 -
+
PASOLINK 155 MB 1+0/1+1 SYSTEM MTD-PL-028/141005

6.9 Performance Monitoring/Metering Items

Item Description Remarks


OFS Sum of out of frame seconds MUX/RADIO direction
BBE Sum of the background block error MUX/RADIO direction
ES Sum of the errored seconds MUX/RADIO direction
SES Sum of the severely errored seconds MUX/RADIO direction
UAS Sum of the unavailable seconds MUX/RADIO direction
TX PWR Transmitter output power Metering item
RX SIGNAL LEVEL Receiver input level Metering item
ODU PS IN VOLTAGE ODU input voltage Metering item
BER MEASUREMENT Bit error rate Metering item

Control Item

IF Loop Back
Baseband Loop Back (near end)
Base band Loop Back (far end)
Modulation off (CW control)
TX Power mute
TX/RX compulsive switching

- 28 -
MTD-PL-032/1401005 NEC Coporation, Tokyo, Japan