Quality Control Check List Project no Section No. Gypsum Drywall 09251 Dave GYPSUM DRYWALL - BOARD “Type, thickness, length, and edges are as required. 26. Type fastener, length, and spacing as required. 27. Installation complies with manufacturer's requirements. 28. Special type used for damp locations it required. 28. Special lengths are provided if required. 30. Verity it horizontal or vertical application is required. 31, Wallboard is installed with staggered application. 32, Imernal and external metal corners as required. 3 Number of coatings required is provided 34. Sanding between coats is performed. 35, Feathering is out 12” to 16": 36. Provide air circulation with adequate dry heat 37. fir-rated, recesses over 16" boxed in. ‘38 Penetrations tight and sealed as required by codes. 39. Verity Contractor has coordinated cutouts, outlet boxes, correctly to avoid patching, ‘40, Require sawing: no scoring or knock-outs. 441, Wallboard is held up from floor 3/8” minimum. 42, Vertical joins are aligned with door jambs. 43 Damaged sheets are not used and are removed. 44. Observe minimum piecing or jointing. 45. Non-metallic cable, plastic. or copper is not damaged. 46. Check for bubbies and dimples. 47. Curing time is adequate. USE REVERSE SIDE FOR ADDITIONAL REMARKS ANO COMMENTS ‘Accepted By