You are on page 1of 9
in CIVIL TECHNOCRATS Pvr. Lr, (Laboratory & Testings, Planning & Designs, Survey & Estimations) 4 An ISO 9001 - 2008 Certified Company ESTD - 2008 Web — : www.civilteknowcrats.com E-mail_: civilteknowcrats@gmail.com Cell No : 99636 98283 99665 03082 Test Report (SID: 7000o5SBC Date of Report =] 25-OTOIT [Report Issued to: Name of Date of Test(=) Conducte To: URAJYALAXMI —_ |t#in Sieve Analysis, 20-07-2017 10 25-07-2017. 5-3: 6a/WO718 “Prem Nagar [Atterberg Limits, IKhirathabad [Direct Shear Test Hyderabad Name of the _ | Proposed Construction of G+5 Building at S.No-19/2,Door ‘No-19-3-37 and 19-3- work: 37/P 1 in Old Renigunta Road, Tirupati Urban,Chittoor District, Ref:~ |Seenu/TPT/Chittoor Distict/Date:20-07-2017. Results S.No. Soil Parameters Results i Te | TP 1 Sample Identification TP1€3.5m| secam | sea5m 2 Gravel % 2 7 6 GRAIN SIZE a | een ‘Sand% io | 80.00 | 650 4 Bilt + Clay % 370 13.00 | 290 5 Liquid Limit % 40 NP NP ATTERBERG 6 cara Plastic Limit _% 8 NP NP 7 Plastic Index _% 22 NP NP 8 Soil Classification (As per 1498 — 1970) sc ‘SM ‘SM 2 Free Swell Mex oo Nil | Nil 10 Dogroe of Expansion Medium | z u SHEAR Cohesion (¢) 50 00 00 1a | pies: ‘Angle of Internal Friction () 2 28.0 26 13 Ultimate Bearing Capacity tim? 4980 | 6920 | 54.00 7 Factor of Safoty 25 25 25 15 Safe Bearing Capacity m2 199) a7 | 216 TNote:= The resulta relate only fo the items tested (i) Tha text report should not be reproduced exeept in full, without il) Any corrections invalidates the test reports (i) Any Query regarding the report must be reported immediately. Prt. Lid. # 23-15-40/1A3, Opp: Mahila University, Padmavathi Nagar, TIRUPATI - 517 502. CIVIL TECHNOCRATS PVT.LTD., TIRUPATI-517502. SUGGESTIONS: 1. Isolated or combined footings may be employed for foundations located at a depth of not less than 3.5 m blow existing ground level. 2. The foundations may be designed for a Safe Bearing Capacity of 18.0 vm? at foundation level. 3. All the footings should rest on lean concrete mat of thickness not less than 15 cm and All the footings should rest on Sand layer thickness is not less than 20cm. 4, Stiff plinth beams would conect the columns in both directions. This renders the sub structure additional rigidity. FIELD VISIT, SAMPLING & TESTING :- ‘The party concerned has been advised to open test pit size of 2.00m X 1.50 m extending to a depth of 3.6 m. The following tests have been conducted soil sample obtained from the field. As per relevant IS Code procedures 1. Grain size analysis 2.Liquid limit 3.Plastic limit 4, Standard Proctor Test 5.Free Swell Index. aT EMAR rv. us TIRUPATI <2 TIVIL TECHNOCRATS Pvt, Lro., \agury § sings, lamas Govom Suey Vea De SUGGS? Set etnes ear est Project.:- Proposed Construction of G*5 Building at S.No-19/2,Door :No-19-9-37 and 19-3-97/F1 in Old| Renigunta Road, Tirupati Urban Chittoor District. | Sieve Analysis Test Pit No.: 2 Depth(m; Weight of sample taken (g): 500 waa, | Seve Aperture [eat [emmamtve e] Arerag® | producto size used (mm) PSR F size (mm) Columns. (2) (3) £1) (3) 7 750 1.80 38.20 4.750 8.55 z 2.000 1.00 97.20 3.375 3.38 3 1.000 70.00 87.20 1.500 15.00 4 0.600 14.80 72.40 0.800 11.84 5 0.425 7.20 65.20 0.513 3.69 6 0.212 17.60 47.60 0.319 5.61 7 0.150 9.60 38.00 0.161 174 8 0.075 7.00 37.00 0.113 ot passing 0.075 49.920 ‘Average Particle Diameter = 0.5200 Description % Particle Size Gravel z Coarse Sand 7 weara Sand % U3: Fine Sand 2 silt & Clay 7 8 e g 8 Silt & Clay Sand Gravel” 0.001 0.010 0.100, 1.000 Particle size [mm] Sf TIVIL TECHNOCRATS Pvt. Lo. ‘8 Designs. Survey & Estimation) AV De ls SSST Boos eee eae eons Project.:- Proposed Construction of G+5 Bullding at S.No-19/2,Door :No-19-3-37 and 19-3-37/F1 in Ole| Renigunta Road, Tirupati Urban,Chittoor District. Sieve Analysis Test Pit No: 2 Depth(m): 3.60 Weight of sample taken (g): 500 sano, | Steve anerture [asa [omamve me] AreraaS | Product of size used (mm) E% size(mm)_| Columns T 750 7.00 35.00 a30 aa 2 2.000 8.60 84.40 3.375 29.03 3 1.000 35.20 49.20 1.500 52.80 4 0.600 19.60 29.60 0.800 15.68 5 0.425 6.60 23.00 0.513 3.38 6 0.212 5.40 17.60 0.319 1.72 7 0.150 4.00 13.60 0.181 0.72 8 0.075 0.40, 13.20 0.113 0.05 3 passing 0.075 | _ _ 136.629 ‘Average Particle Diameter = 1.4232 Description Particle Size ravel Coarse Sand Fine Sand Silt & Clay g g g 8 silt & Clay Sand Gravel” Cumulative Percentage Fin: 0.001 0.010 1.000 Sale TIVIL TECHNOCRATS | Lage Uo. \caboratory & Towunon, Plane © bot hye an'iga'300 ‘erined Come ns Project. Proposed Construction of G+5 Bullding at S.No-19/2,Door Renigunta Road, Tirupati Urban Chittoor District. Sieve Analysis Test Pit No.: 3, Depth(m): 3.50 Weight of sample taken (9): 500 19-397 and 19-3.37/P1 in O1d| ‘% Soil] Cumulative %] Average Sieve Aperture | retained nae 9¢ | Product of size used (mm) [pea a E ‘Columns —| 2) x13) | 4.750 11.60) 88.40 [55.10 2.000 640 | 82.00 — 21.60 1.000 26.00 36.00 39.00 0.600 15.20 40.80 12.16 | 0.425 5.80 35.00 | 2.87 0.212 6.00 29.00 1.91 0.150 6.60 22.40 1.19 0.075 0.80 21.60 0.09 passing 0.075 134.031 ‘Average Particle Diameter = 1.3962 Description %o Size ‘Gravel T. Coarse Sand Tae reat Sar ri 139 Fine Sand a3 Sik 2 a g g 8 ‘Silt & Clay Sand Gravel” 100 90 80 7” 6 Cumulative Percentage Finer 8 0.001 0.010 1.000 Particle size [mm] CIVIL TECHNOCRATS PVT.LTD., TIRUPATI-517502. DETERMINATION OF LIQIUD LIMIT S.No DESCRIPTION uaiLS 1 x 3 4 1__|Weight of soil sample,(gms) 100 100 100 100 2 [Amount of water added, (%) 36 40 45 50 3 _|No. of Blows(N) 4 |Container Number 13 3 i* 10 5 [Weight of container,(gms) 20 23 22 18 6 __|Weight of wet sample + container (gm) 74 66 68 56 7 |Weigth of dry sample + Container (gms) 62 54.5 53.6 42 8 Weight of water (g) 12 115 14.4 14 5 | Weight of oven dry sample (g) 42 31.5 31.6 24 10 |Water content (%) 28.57, 36.51 45.57, 58.33 Liquid Limit 40 Liquid limit 100.00, 90.00 _ 80.00 =z 70.00, eZ 60.00 § 50.00 g 40.00 8 30.00 s$ 20.00 ———— = = 10.00 - = - ug No. of Biows(4), 7 i 2 CIVIL TECHNOCRATS PVT.LTD., TIRUPATI-517502. DETERMINATION OF PLASTIC LIMIT S.no Description uel if 2 1 [Container No 1 9 2 [Weight of container (gm) 24 20 3 [Weight of container + wet soil (gm) 375 316 4 [Weight of container + Dry soil (gm) 35 29.8 5 _ [Weight of water in (gm) 25 18 6 _|Weight of ovendry soil (gm) 4 98 7 [Water Content (%) 17.86 18.37 Result: _|Plasctic Limit (PL)% 13 Liquid Limit (LL) % “0 Plasticity Index _(WL-PL) = PI % 2 Soil Classification : sc DATA FOR SBC CALCULATIONS - Ground Level 0.000 Width of Foundation, B= 150 ™ FoundationStratum = ‘Sand Clay s = 2 Degrees Gia cs kN/m? 1 = 16 kN/m? Length = 1.50 m Foundation Load Inclination, a ° Degrees FactorOfSafety = = 25 Foundation Shape Code 3 Strip | Rectangular [Square Gireular 1 2 3 4 In Accordance with 18: 6403-1981 SHAPE FACTORS SHAPE OF BASE SHAPEFACTONS 3. Sa 5, [Continuous strip 100 100 7100 Rectanguta 02) | 4026/4) | 1046/1) [square 130 120 0.80 Circe 130 720 0.60 ‘DEPTH FACTORS Influence Factor DEPTH FACTORS: ‘Table 2 of 1S:8009, Part 1 a Ty C3 Shape Average Forany value of @ | Fora value of §> 10 degrees Circle 0.85 45+4/2) Square 0.95: 1+0.2x(D/B)x {5-4/2 Tansee) [Poravalue of < 10 degrees Rectangle 1.00 1B ‘INCLINATION FACTORS 15 iz t iF z z TST a7 9/9 —| Tare 3 @& 6 are in degrees 10 2.25 100 2.96 Qp = 4 (Nat) 55d ig + Where Yo ae Boe D = Reus c = NeNyN, = S/8y8, = dy dy dy = ivigi, = SBCCALCULATIONS - 0 05 Bg Ng, dgig W'+ CN, 8 de i Bulk unit weight of foundation soil = 17.6 KN/m Erfective Surcharge atthe base of foundation ( kN/a*) 26.6 KN/m* Width of Footing 150 m Depth of Foundation, m 3.50 m Angle of shering resistance of soil in degrees 22 Degrees Cohesion 5.00 KN/m* Bearing capacity factors N. [Ns Ny Refer I:6403 asa2]_ 779 [7a Shape Factors Serer Ser |r 130 | 120 | 080 Depth Factors a?a | 4 roo | 1346 [1346 Inclination of the load to the vertical in degrees 0 Degrees Inclination Facors ie qT 100 | 1.00 | 1.00 Water table correction os ‘The Sub-Soil Water Table is considered to be at GL. as the worest case Qu = 26.6 x (7.79-1) x 1.12x1.346x1 $05x15x17.6x7:1x0.77x1346x1x05 +5x 16.82% 1.12 x 1.691 x1 202 + 2179 + «(18488 = 498 KN/m? Qsae = 199 KN/m? Consider an allowable SBC of 180 KN/m? Elastic Settlement (as per IS: 8009 - Part -1) Si = pxBx(1-w)xI/E P= Contact Pressure B = Widthof Foundation 1.50. m L_ = Lengthof Foundation 1.50 m h= Poission Ratio 03 E = Young's modulus= 250*(15+N) —- KN/m? 1 = Average Influence factor B= 10 095 D/(L xB)” = 2333 AS per Table No. 2 of IS: 8009 - Part 1) I 0.95 Refer Table 2 of 1S:8009, Part 1 N = 50 where N is Average SPT value within influence depth below E = 16250 KN / Sqm Si = oom m = 14364 mm Depth Correction Factor = 0.98 From Fig No. 12 of 1S:8009, Part 1 Rigidity Factor = 0.80 As per Clause 9.52 of 15:8009 - Part 1 Settlements after corrections = 11.26 mm Allowable elastic Settlement = 50 mm AS SETTLEMTS ARE WITHIN LIMITS, SAFE Hence Recommended SBC = 180 kN/mm’

You might also like