FSCCT
Assistant Professor of Radiology and
Cardiology
Vice Chairman of Radiology
University of British Columbia
Disclosures
L
Leon MB,
MB ett al. N Engl J Med. 2010 2010;363:1597-1607.
What we know about PV Leak
Piazza N et al. Anatomy of the Aortic Root. Circ Cardiovascular Interventions. 2008
The Annulus is Elliptical
Tops LF, Wood DA, Delgado V, et al. Noninvasive evaluation of the aortic root
with multislice computed tomography: implications for transcatheter aortic valve replacement.
JACC Cardiovasc Imaging 2008; 3:25 -32
MDCT Provides Reproducible
Measurements of the Annulus that provide
a granular assessment of root geometry
Advantages to MDCT methods
Greater reproducibility
Less sensitive to minor changes in obliquity
3-D
2D
Creating the Basal Ring
Leipsic et al Radiology
Example of Incorrect Plane Too Low
Double
Oblique Oblique
Coronal Axial
Oblique
Sagittal 3D
Example of Incorrect Plane Wrong Orientation
Double
Oblique Oblique
Coronal Axial
Oblique
Sagittal 3D
Inter-reader reliability as measured by ICC*, estimates and 95% CI for 3
readers (n=50).
Basal Ring
Sagittal Short axis Long axis
Coronal 3-chamber Average Area
oblique basal ring basal ring
Diameter
0.78 0.71
0.54 0.72 0.70 0.82 0.87
(0.67, (0.59,
(0.39, 0.69) (0.61, 0.82) (0.58, 0.81) (0.72-0.88) (0.81- 0.92)
0.85) 0.81)
Mean diameter
0.87 0.79 -0.90
Area
0.86 0.65-0.90
Long diameter
0.77 0.71-0.83
Short diameter
0.70 0.49-0.82
Absolute p Relative p
change change
CSA 72.922.6mm2 18.26.1%
<0.001 <0.001
Perimeter 5.41.5mm 7.32.1%
DA 2.00.6mm 8.72.8%
<0.001 <0.001
DP 1.70.5mm 7.32.1%
Limitations of Perimeter
Measurements
Coronary Ostial Height
ILEOFEMORAL ASSESSMENT
CT Screening Can Reduce your
Vascular Access Complications
ILIOFEMORAL ACCESS
complication complication
n = 58 n=8
diameter, n (%)
(%)
30
25
2008
20
2009
15 2010
10
0
Minor (p=.02) Major (p<0.001)
STENTS REMAIN
CIRCULAR
NO VALVE MIGRATION:
Distance from left main
3.0 3.6mm vs 1.9 3.7mm,
p=0.24
NO VALVE FRACTURE
Gurvitch R, Wood D, Leipsic J et al. Circulation. Sept 2010
Self Expandable Valves: Geometry
Higher eccentricity and incomplete expansion compared
with balloon expandable valve *
* Schultz CJ, Weustink A, Piazza N et al. Geometry and degree of apposition of the CoreValve ReValving system with multislice
computed tomography after implantation in patients with aortic stenosis. J Am Coll Cardiol. 2009;54:91118
CONCLUSION
TAVR therapy has seen rapid advancements over the
last 5 years
MDCT can evaluate
3D annular and aortic root morphology and
dimensions
MDCT measures of the annulus are predictive of PAR
and can provide more granular and reproducible
annular sizing
Assessment of iliofemoral access
Procedural planning- angle prediction and left main
height assessment