Totally Integrated

Automation Portal

Main1 [OB1]
Main1 Properties
General
Name Main1 Number 1 Type OB
Language LAD Numbering Automatic
Information
Title "Main Program Sweep Author Comment
(Cycle)"
Family Version 0.1 User-defined
ID

Name Data type Default value


Temp
OB1_EV_CLASS Byte
OB1_SCAN_1 Byte
OB1_PRIORITY Byte
OB1_OB_NUMBR Byte
OB1_RESERVED_1 Byte
OB1_RESERVED_2 Byte
OB1_PREV_CYCLE Int
OB1_MIN_CYCLE Int
OB1_MAX_CYCLE Int
OB1_DATE_TIME Date_And_Time
Status Rot DInt
Constant

Network 1:

%MW10 %MW10
%M2.0
"Flujo" "Flujo" "1 Bomba"
> <=
Int Int
0 25

Network 2:

%MW10 %MW10
%M2.1
"Flujo" "Flujo" "1 y 2 Bomba"
>= <=
Int Int
26 50
Totally Integrated
Automation Portal

Network 3:

%MW10 %MW10
%M2.2
"Flujo" "Flujo" "1 2 y 3 Bomba"
>= <=
Int Int
51 100

Network 4:

%M2.0 %M70.0 %M50.0


"1 Bomba" "Pulse SEQ 1 Run" "SEQ 1 Running"
P S
%M40.0
"Mem Pulse"

Network 5:

%M2.0 %M2.1 %M2.2 %M50.0


"1 Bomba" "1 y 2 Bomba" "1 2 y 3 Bomba" "SEQ 1 Running"
R

%M0.3 %M0.4 %M1.3 %M0.6


"Manual Auto "Manual Auto "Bypass SEQ "Stop SEQ"
Pump 1" Pump 2" Pump 3"

%M0.4 %M0.5 %M1.4


"Manual Auto "Manual Auto "Bypass SEQ
Pump 2" Pump 3" Pump 1"

%M0.3 %M0.5 %M1.5


"Manual Auto "Manual Auto "Bypass SEQ
Pump 1" Pump 3" Pump 2"

Network 6:
Totally Integrated
Automation Portal

%DB5
"SQC 1 Timer 1"
%M50.0 %M0.6 TON
"SEQ 1 Running" "Stop SEQ" Time
IN Q
T#10S PT %MD30
%M60.2 "Timmin SEQ 1
"SEQ 1 - Next B1" ET TM1"

%DB5.DBX6.0
"SQC 1 Timer %M60.0
1".Q "SEQ 1 - Next B2"
S

%M0.3 %M50.0
"Manual Auto "SEQ 1 Running"
Pump 1" R

%M60.2
"SEQ 1 - Next B1"
R

Network 7:

%DB4
"SQC 1 Timer 2"
%M60.0 %M0.6 TON
"SEQ 1 - Next B2" "Stop SEQ" Time
IN Q
T#10S PT %MD34
"Timmin SEQ 1
ET TM2"

%DB4.DBX6.0
"SQC 1 Timer %M60.1
2".Q "SEQ 1 - Next B3"
S

%M0.4 %M60.0
"Manual Auto "SEQ 1 - Next B2"
Pump 2" R

Network 8:
Totally Integrated
Automation Portal

%DB3
"SQC 1 Timer 3"
%M60.1 %M0.6 TON
"SEQ 1 - Next B3" "Stop SEQ" Time
IN Q
T#10S PT %MD120
"Timmin SEQ 1
ET TM3"

%DB3.DBX6.0 %M60.2
"SQC 1 Timer 3".Q "SEQ 1 - Next B1"
S

%M0.5 %M60.1
"Manual Auto "SEQ 1 - Next B3"
Pump 3" R

Network 9:

%DB5.DBD8
%M0.3
"SQC 1 Timer %M2.0 "Manual Auto %M200.0
1".ET Pump 1"
"1 Bomba" "Runing Pump 1"
>
DInt
T#0MS
%M2.1
"1 y 2 Bomba"

%M1.4
"Bypass SEQ
Pump 1"

%M2.1 %M200.2 %M200.1


"1 y 2 Bomba" "Runing Pump 3" "Runing Pump 2"

%M2.2
"1 2 y 3 Bomba"

%M0.3 %M0.1 %M0.2


"Manual Auto "Start Manual "Stop Manual
Pump 1" Pump 1" Pump 1"

%M200.0
"Runing Pump 1"

Network 10:
Totally Integrated
Automation Portal

%DB4.DBD8
%M0.4
"SQC 1 Timer %M2.0 "Manual Auto %M200.1
2".ET Pump 2"
"1 Bomba" "Runing Pump 2"
>
DInt
T#0MS
%M2.1
"1 y 2 Bomba"

%M1.5
"Bypass SEQ
Pump 2"

%M2.1 %M200.0 %M200.2


"1 y 2 Bomba" "Runing Pump 1" "Runing Pump 3"

%M2.2
"1 2 y 3 Bomba"

%M0.4 %M0.7 %M1.0


"Manual Auto "Start Manual "Stop Manual
Pump 2" Pump 2" Pump 2"

%M200.1
"Runing Pump 2"

Network 11:
Totally Integrated
Automation Portal

%DB3.DBD8
%M0.5
"SQC 1 Timer %M2.0 "Manual Auto %M200.2
3".ET Pump 3"
"1 Bomba" "Runing Pump 3"
>
DInt
T#0MS
%M2.1
"1 y 2 Bomba"

%M1.3
"Bypass SEQ
Pump 3"

%M2.1 %M200.1 %M200.0


"1 y 2 Bomba" "Runing Pump 2" "Runing Pump 1"

%M2.2
"1 2 y 3 Bomba"

%M0.5 %M1.1 %M1.2


"Manual Auto "Start Manual "Stop Manual
Pump 3" Pump 3" Pump 3"

%M200.2
"Runing Pump 3"