é Say
P.A.Hilton LtdEXPERIMENTAL
OPERATING
AND
MAINTENANCE PROCEDURES
OPTIONAL
LINEAR HEAT CONDUCTION UNIT
H112A
H112A_E_1_107
NOV 11TYPICAL INSTALLATION...
HII2 shown with HIT2A Linear Heat Conduction Unit and HC112A
1
1
HII2A shown without intermediate specimen... ne poten
Specimen supplied. 2
SCHEMATIC H112A Linear Heat Conduction Unit...
DESCRIPTION
Brass Specimen se.
Stainless Stee! Specimen...
Aluminium Specimen.
Brass Specimen with Reduced Diameter.
INSTALLATION...
Temperature Sensors
Heating Element.
Cooling Water Supply.
Cooling Water Drain.
OPERATING PROCEDURE ...
MAINTENANCE
Water Cooling Circuit 8
Itermedite Section 8
Toggle Clamps 8
Heated and Cooled Sections Adjustment.........+.00 ose . 8
USEFUL DATA
(CAPABILITIES OF THE LINEAR HEAT TRANSFER UNIT H112A WITH THE HEAT
TRANSFER SERVICE UNIT HI12 .«
1. To measure the temperature distribution for steady state conduction of energy through a
uniform plane wall and demonstrate the effect of a change in heat flow. sevsnnennn LD
2. Tounderstand the use of the Fourier Rate Equation in determining rate of heat flow through
solid materials for one dimensional, steady flow of heat... worn
2. To understand the use of the Fourier Rate Equation in determining rate of heat flow through
solid materials for one dimensional, steady flow of heat eset connie lO
3. To measure the temperature distribution for steady state conduction of energy through a
‘compasite plane wall and determine the Overall Heat Transfer Coefficient for the flow of heat
through a combination of different materials in use. ose 21