You are on page 1of 40

OptiX RTN 900 V1R1

Installation Guide

www.huawei.com

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


CONTENTS

Mandatory Rules
Installation

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Mandatory Rules
Rules Description Requirement
1 Operate IF boards ODU- Before turning the toggle lever switch, Every team, every
PWR switch accurately . you must pull it out slightly. member should and
Otherwise, the switch will be broken, must know it.
and the project will be delayed.
2 Do not remove or insert Before removing or inserting the IF Every team, every
the IF Jumper when the Jumper, you must power off the ODU member should and
ODU is powered on. (turn off the switch of IFE2 ODU- must know it.
PWR).
Otherwise, the board will be
damaged, and the project will be
delayed.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Mandatory Rules
Before turning the toggle lever switch, you must pull i t out slightly.

The right operation method.

The damaged boards by wrong


operation method.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Mandatory Rules
Before removing or inserting the IF Jumper, you must power off the ODU.

Do not remove or insert the IF


cable when the ODU is
powered on.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Mandatory Rules
Before removing or inserting the IF Jumper, you must power off the ODU.

IF cable is easy to short on the


tower, it will damage the IFE2 if
power is ON.

Do not remove or insert the IF


cable when the ODU is
powered on.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Mandatory Rules
Before removing or inserting the IF board, you must power off the ODU.

Do not remove or insert the IF


board when the ODU is powered on.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Mandatory Rules
Dont open the ODU, and dont tear up the seal.

Move and install the ODU carefully.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


CONTENTS

Mandatory Rules
Installation

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Installation Before You Start
Checking the Power System
Items that need to be checked include the AC power system and the DC power system.
Table Checklist for the power system

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


IDU Installation
RTN 900 Power Specification

Power Specifications RTN 910 RTN 950

power consumption 52 (without microwave) 90(without microwave)


(with typical configuration) (W) 114 (with microwave) 203 (with microwave)

95 (without microwave) 218 (without microwave)


Maximum power consumption (W)
176 (with microwave) 495 (with microwave)

Voltage range (V, DC) - 38.4 to - 72.0 - 38.4 to - 72.0

2.6 (without microwave) 6 (without microwave)


Maximum current (A)
5 (with microwave) 14.3 (with microwave)

Fuse dimenssion 12 A 20 A

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


IDU Installation
RTN 900 Hardware Structure

RTN 910 RTN 950


Weight (kg) Empty chassis: 1.97 Empty chassis: 2.80

Dimension 442 mm (width) x 220 mm (depth) x 1 U 442 mm (width) x 220 mm (depth) x 2 U (height,
(height, 1 U = 44.45 mm). 1 U = 44.45 mm).

The OptiX RTN 900 can be installed in the following:


- ETSI cabinet (300 mm deep)
- ETSI cabinet (600 mm deep)
- 19 inch cabinet (450 mm deep)
- 19 inch cabinet (600 mm deep)
- Open rack
- Wall
- Desktop

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


IDU Installation steps
Installing the IDU in a 19 Rack

PGND

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


IDU Installation
Installing the IDU in a ETSI Rack

For ETSI rack, RTN 900


IDU should install transfer
fixer.

For ETSI rack, RTN 900


IDU should install PGND
cable ahead, then install
the IDU in the rack..

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


IDU Installing
Installing the Power Cable

If the power cable


isnt assembled in
factory, it needs to
be made in site.
Warning
The conductor of power cable
must insert the connector
completely, prevent getting an
electrical shock!

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


IDU Installing
For 1+1, the IF cable between IFE2 and ODU should be connected correctly.
Working IFE2 IF cable cant connect with standby ODU.

working protection

Slot3: working board.


Slot4: protection board.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


IDU Installing
Installing the E1 Cable

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


IDU Installing
Installing the E1 Cable

The table of all pin assignments is packed with


the cable.E1 cable installing should according to it.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


IDU Installing
Installing the E1 Cable

The table of all pin assignments is packed with


the cable.E1 cable installing should according to it.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


IDU Installing
CXPA/CXPB Cable Interface

1 2 3 4 5 6 7 8
Interface on the Interface Usage Remark
Front Panel Type
1 ETH OAM RJ-45 10Base-T/100Base-TX NM Ethernet interface For WEBLCT
or NM serial interface

2 CLK1/TOD1 RJ-45 External clock/time input/output interface


3 CLK2/TOD2 RJ-45 External clock/time input/output interface
4 EXT/S1 RJ-45 10Base-T/100Base-TX extended Ethernet
interface or 64k transparent data interface

5 PHONE RJ-45 Orderwire interface


6 ALMI/ALM0 RJ-45 3 x alarm inputs and 1 x alarm output interface
7 FE1 - FE4 RJ-45 Input/output interface for FE electrical signals For FE service

8 E1(1 - 16) Anea 96 E1 service input/output interface For E1 service


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
IDU Installing
EF8T/EF8F Cable Interface

EF8T: 8 x FE electrical signals.

EF8F: 8 x FE electrical signals.

EF8T: Accesses 8 x FE electrical signals.


EF8F: Accesses 8 x FE optical signals.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


IDU Installing
Cable Routing and Sequence (from 1 to 4).

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Installation ODU
Installing an ODU on an Antenna

In this case, use four latches to mount an ODU on the back of the antenna.
Follow the steps below:

1 Installing the Antenna


Following the instructions packed with it, install the antenna.

2 Setting the Antenna Polarization


By default, the antenna applies vertical polarization. If horizontal polarization is required,
rotate the feed boom at the back of the antenna to change the polarization direction of
the antenna.

3 Installing the ODU on the Antenna


Use four latches to mount the ODU on the antenna.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Installation ODU
Setting the Antenna Polarization
By default, the antenna applies vertical polarization. If horizontal polarization is required,
rotate the feed boom at the back of the antenna to change the polarization direction of
the antenna.
Procedure
Step 1 Check if the antenna is vertically polarized.

Step 2 Loosen the fixing bolts enough to allow the feed boom to rotate freely.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Installation ODU
Step 3 Rotate the feed boom 90 degrees to the right or left until its positioning pin plugs into
the positioning slot in the base.

Figure Horizontally polarized antenna

Step 4 Tighten the fixing bolts.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Installation ODU
Installing the ODU on the Antenna

Procedure
Step 1 Remove the protective caps from the feed boom of the antenna and from the
ODU antenna interface. Apply appropriate lubricant to the gasket of the feed boom.

Step 2 Place the ODU antenna interface against the feed boom. Slowly fit the feed
boom in to make the four ODU latches engage the four antenna hooks.

Figure Installing the ODU on the antenna (vertically polarized)

Next page

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Installation ODU

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Installation ODU

Installing Two ODUs on an Antenna


In this case, use a hybrid coupler to mount two ODUs on the back of the antenna.

Setting the Antenna Polarization

By default, the antenna applies vertical polarization. If horizontal polarization is required,


rotate the feed boom at the back of the antenna to change the polarization direction of
the antenna.

Procedure
Step 1 Check the polarization direction of the antenna.
If The antenna is vertically polarized, Go to the next step.
The antenna is horizontally polarized, Go to Step 3.

Step 2 Remove the protective cap from the antenna interface on the coupler. Replace the
polarization converter in the interface by a horizontal polarizer.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Installation ODU
Step 3 Remove the protective caps from the feed boom and the antenna interface. Apply
appropriate lubricant to the gasket of the feed boom.

Figure 4Installing the ODU on the hybrid coupler

Step 4 Close the four latches cornerwise.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Installation ODU Cables

Installing the ODU Protection Grounding Cable

Procedure
Step 1 Fix the OT terminal of the protection grounding cable onto the grounding stud of
the ODU.

Step 2 Connect the other end of the protection


grounding cable to the grounding point on the
tower that
is the nearest to the ODU.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Installation ODU Cables

Installing the IF Cable


One end of the IF cable is connected to the ODU, while the other end is connected to the
IF jumper from the IDU.

Procedure
Step 1 Depending on the distance between the IDU and the ODU, cut off a length of IF
cable with a slack of 3 m to 5 m.

Step 2 Refer to A Terminating the IF Cable with Connectors, make a connector for the
end that is connected to the ODU.
Take protective measures for the connector to avoid damage to the connectors during
installation.

Step 3 Affix temporary labels to both ends of the IF cable.

Step 4 Leave enough slack of the IF cable for routing and binding it along the mast,
wiring ladder and wiring frame.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Installation ODU Cables

Figure 5-2 Waterproof curves before the IF cable enters the IDU room

Step 5 Insert the type-N male connector of the IF cable to the IF interface of the
ODU and screw tight.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Installation ODU Cables
Figure 5-3 Connecting the IF cable to the ODU

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Grounding the IF Cable
In general, the IF cable should be The 3 grounding kits must
grounded to a minimum of three points. be mounted.
When the IF cable is longer than 60
meters, add a grounding point for every
extra 50 meters.
The place about 1 m away from the
ODU and 1 m away from the cable entry
are propositional grounding point.
All of outdoor connector should be
waterproofed.

1,2,3,4:IF Cable Grounding Point.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Check IF Cable Installation
The angle between IF cable and
grounding cable is the smaller the better.

The angle should <15.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Check IF Cable Installation
You should scrape the paint on the iron
before mounting the grounding kits.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Check IF Cable Installation
Porthole: IF cable must be up-tilted or
have Waterproof curve in the entrance of
porthole.
The IF cable route and position for the
cabling should be designed beforehand
and arranged neatly. IF cable turns
should be smooth, and the bending
radius should be larger than 30 cm.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 36


Check IF Cable Installation
All of outdoor connector should be
waterproofed.

The ODU IF interface should be


waterproofed.

The area for grounding kit


should be waterproof.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Check IF Cable Installation
The operation of waterproof must be
regular.

Wrapping a layer of PVC Wrapping three layers of