Installation Guide
www.huawei.com
Mandatory Rules
Installation
Mandatory Rules
Installation
Fuse dimenssion 12 A 20 A
Dimension 442 mm (width) x 220 mm (depth) x 1 U 442 mm (width) x 220 mm (depth) x 2 U (height,
(height, 1 U = 44.45 mm). 1 U = 44.45 mm).
PGND
working protection
1 2 3 4 5 6 7 8
Interface on the Interface Usage Remark
Front Panel Type
1 ETH OAM RJ-45 10Base-T/100Base-TX NM Ethernet interface For WEBLCT
or NM serial interface
In this case, use four latches to mount an ODU on the back of the antenna.
Follow the steps below:
Step 2 Loosen the fixing bolts enough to allow the feed boom to rotate freely.
Procedure
Step 1 Remove the protective caps from the feed boom of the antenna and from the
ODU antenna interface. Apply appropriate lubricant to the gasket of the feed boom.
Step 2 Place the ODU antenna interface against the feed boom. Slowly fit the feed
boom in to make the four ODU latches engage the four antenna hooks.
Next page
Procedure
Step 1 Check the polarization direction of the antenna.
If The antenna is vertically polarized, Go to the next step.
The antenna is horizontally polarized, Go to Step 3.
Step 2 Remove the protective cap from the antenna interface on the coupler. Replace the
polarization converter in the interface by a horizontal polarizer.
Procedure
Step 1 Fix the OT terminal of the protection grounding cable onto the grounding stud of
the ODU.
Procedure
Step 1 Depending on the distance between the IDU and the ODU, cut off a length of IF
cable with a slack of 3 m to 5 m.
Step 2 Refer to A Terminating the IF Cable with Connectors, make a connector for the
end that is connected to the ODU.
Take protective measures for the connector to avoid damage to the connectors during
installation.
Step 4 Leave enough slack of the IF cable for routing and binding it along the mast,
wiring ladder and wiring frame.
Figure 5-2 Waterproof curves before the IF cable enters the IDU room
Step 5 Insert the type-N male connector of the IF cable to the IF interface of the
ODU and screw tight.