Isolated Footing Design (IS 456-2000)
Isolated Footing Design (IS 456-2000)
Isolated Footing 1
file:///F:/Staad%20Foundation%20Advanced/CalcXsl/footing.xml 22/08/2013
Isolated Footing Design Page 2 of 42
Input Values
Footing Geomtery
Column Dimensions
Pedestal
Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A
file:///F:/Staad%20Foundation%20Advanced/CalcXsl/footing.xml 22/08/2013
Isolated Footing Design Page 3 of 42
Design Parameters
Soil Properties
Global Settings
Top Reinforcement Option : Calculate only when foundation is subjected to uplift forces
Concrete Design Option : Gross Pressure
------------------------------------------------------
Design Calculations
file:///F:/Staad%20Foundation%20Advanced/CalcXsl/footing.xml 22/08/2013
Isolated Footing Design Page 4 of 42
------------------------------------------------------
Footing Size
(Service check is performed with footing thickness requirements from concrete check)
------------------------------------------------------
file:///F:/Staad%20Foundation%20Advanced/CalcXsl/footing.xml 22/08/2013
Isolated Footing Design Page 5 of 42
Area of
Pressure at Pressure at Pressure at Pressure at footing in
Load Case corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4) uplift (Au)
(kN/m2) (kN/m2) (kN/m2) (kN/m2)
(m2)
If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of
negative pressure will be set to zero and the pressure will be redistributed to remaining corners.
------------------------------------------------------
Check For Stability Against Overturning And Sliding
Critical Load Case And The Governing Factor Of Safety For Overturning and Sliding X Direction
Critical Load Case for Sliding along X-Direction : 102
Governing Disturbing Force : -0.920kN
file:///F:/Staad%20Foundation%20Advanced/CalcXsl/footing.xml 22/08/2013
Isolated Footing Design Page 6 of 42
------------------------------------------------------
Moment Calculation
= 0.479107
Limiting Factor1 (Kumax) =
file:///F:/Staad%20Foundation%20Advanced/CalcXsl/footing.xml 22/08/2013
Isolated Footing Design Page 7 of 42
= 0.479107
Limiting Factor1 (Kumax) =
------------------------------------------------------
Shear Calculation
file:///F:/Staad%20Foundation%20Advanced/CalcXsl/footing.xml 22/08/2013
Isolated Footing Design Page 8 of 42
Ks = = 1.000
Ks x Tc = 1118.0340kN/m2
------------------------------------------------------
Reinforcement Calculation
file:///F:/Staad%20Foundation%20Advanced/CalcXsl/footing.xml 22/08/2013
Isolated Footing Design Page 9 of 42
Along X Axis
Along Z Axis
file:///F:/Staad%20Foundation%20Advanced/CalcXsl/footing.xml 22/08/2013
Isolated Footing Design Page 10 of 42
Smin<= S <= Smax and selected bar size < selected maximum bar size...
8 @ 140.000mm o.c.
8 @ 140.000mm o.c.
file:///F:/Staad%20Foundation%20Advanced/CalcXsl/footing.xml 22/08/2013
Isolated Footing Design Page 11 of 42
------------------------------------------------------
file:///F:/Staad%20Foundation%20Advanced/CalcXsl/footing.xml 22/08/2013
Isolated Footing Design Page 12 of 42
Isolated Footing 2
Input Values
Footing Geomtery
Column Dimensions
Pedestal
Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
file:///F:/Staad%20Foundation%20Advanced/CalcXsl/footing.xml 22/08/2013