S13
Apex Connection - Ver W2.6.01 - 16 Jan 2013

Title : Example
Code of Practice : BS5950 - 1990
Created : 12/6/2017 9:33:55 AM

Notes and Assumptions


1 All bolt holes are assumed to be normal clearance holes.
2 All bolts are assumed to have threads in their shear planes.
3 It is assumed that the connection is deep enough for the flanges
to resist the compressive and tensile forces in them.

Summary

Summary of Forces and Capacities for Design to BS5950 - 1990

Check Member Type LC Applied Capacity Units % of Cap. ?

1 Weld Flange 104 684 474.4 kN 144.2 Fail

2 Weld Web 103 73.2 907.2 kN 8.1 O.K.

3 Bolts Shear 103 7.3 10.5 kN 70 O.K.

3b Bolts Slip N/A N/A N/A kN N/A N/A

4 Bolts Combined 101 10.5 1.4 kN 748.7 Fail

5 Bolts & Plate Tension & Bending 101 264 25.2 kN 1048 Fail

6 Plate Bearing 103 7.3 54.6 kN 13.4 O.K.

Input

General Settings
Bolt Tension Analysis Plastic
Bolt Type Bearing
Bolt Grade 3.6
Member Ultimate Strength 200
Member Yield Strength 150
Weld Ultimate Strength 200
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Connection Type Extended End Plate : Top & Bottom


Beam 610x305x149 I1
Beam Angle 0
Haunch Depth (mm) 0
Haunch Length (mm) 0

Ultimate Limit State Loads in Beam


SLS Factor
Load Case Shear Axial Moment

101 -0.128 -526.901 -0.344 1


102 0.128 534.258 -0.271 1
103 -73.242 375.157 55.173 1
104 73.242 -367.801 296.388 1
105 -23.917 -87.552 -108.339 1
106 70.216 -351.687 297.762 1

Width (mm) 350


Extent Above Beam Flange (mm) 100
End Plate
Extent Below Beam Flange (mm) 100
Thickness (mm) 20

Bolts Diameter (mm) 12


Above Top Flange 1
Below Top Flange 3
Rows of Bolts
Above Bottom Flange None
Below Bottom Flange 1
Row Spacing (mm) 200
Web (mm) 75
Bolt Offsets
Flange (mm) 50
Above Haunch (mm) N/A

Beam Flanges (mm) 12


Weld Sizes
Beam Web (mm) 12

Check 1 : Capacity of the Beam Flange Welds


The worst load is encountered for Load Case : 104
Bmax = 683.965 kN

The Capacity of weld is the lesser of : 6.6.5.5


Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

0.5 . Aw. Ue
Pw =
1000
0.5 4 744.32 200
=
1000
= 474.432 kN

0.54 . Aw. Us
Pw =
1000
0.54 4 744.32 200
=
1000
= 512.387 kN

Beam Flange Weld failure

Check 2 : Capacity of the Beam Web Welds


The worst load is encountered for Load Case : 103
Bmax = 73.242 kN

The Capacity of weld is the lesser of : 6.6.5.5

0.5 . Aw. Ue
Pw =
1000
0.5 4536 200
=
1000
= 453.600 kN

0.54 . Aw. Us
Pw =
1000
0.54 4536 200
=
1000
= 489.888 kN

Beam Web Weld is safe

Check 3 : Shear Capacity of the Bolts


The worst load is encountered for Load Case : 103
when Fsmax =7.324 kN

6.3.2
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

The resistance of any bolt is :

ps. As
Ps =
1000
10.47 88.216
=
1000
= 0.9236 kN

Bolt shear is safe

Check 4 : Shear and Tension Capacity of the Bolts


The worst load is encountered for Load Case : 101

6.3.6.3
The factor must be less than or equal to 1.4 :
Fs Ft
Factor = +
Ps Pt
0.013 131.993
= +
10.47 12.594
= 10.482

Bolt shear and tension failure

Check 5 : Bolt tension and End Plate Bending


The worst load is encountered for Load Case : 101

Fmax = 263.986 kN
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

The resistance is the smaller of the 3 possible failure modes :

Mode 1 : Complete yielding of the End Plate

4 . Mpl .
R1 = 1000
m
4 2.625
= 1000
50
= 210.000 kN

Mode 2 : Bolt Failure with yielding of the End Plate

2 . Mpl . 1000 + n . 2 . Bt
R2 =
m+n
2 2.625 1000 + 50 2 12.594
=
50 + 50
= 65.094 kN

Mode 3 : Bolt Failure only

R3 = 2 . Bt
= 2 12.594
= 25.188 kN

Therefore R = R3 = 25.189

Bolt tension or end plate bending failure

Check 6 : Bearing of the End Plate


The worst load is encountered for Load Case : 103
with Fb = 7.324 kN

The Bearing Capacity of the Plate at any Bolt is the lesser of :


6.3.3.3
d . t . pbs
Pbs =
1000
12 20 227.5
=
1000
= 54.600 kN

And

6.3.3.3
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

1. . .
e t pbs
2
Pbs =
1000
1
50 20 227.5
2
=
1000
= 113.750 kN

End plate bearing is safe


Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Bolt Forces (Forces are given per bolt and not per row)

Bolt Forces for Load Case : 101

32.93 kN

32.93 kN

32.93 kN

32.93 kN

131.99 kN

Shear force per bolt : 0.01 kN

Bolt Forces for Load Case : 102

0 kN

0 kN

0 kN

0 kN

0 kN

Shear force per bolt : 0.01 kN


Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Bolt Forces for Load Case : 103

0 kN

0 kN

0 kN

0 kN

0 kN

Shear force per bolt : 7.32 kN

Bolt Forces for Load Case : 104

111.68 kN

111.68 kN

111.68 kN

111.68 kN

91.95 kN

Shear force per bolt : 7.32 kN


Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Bolt Forces for Load Case : 105

5.47 kN

5.47 kN

5.47 kN

5.47 kN

106.17 kN

Shear force per bolt : 2.39 kN

Bolt Forces for Load Case : 106

111.09 kN

111.09 kN

111.09 kN

111.09 kN

87.92 kN

Shear force per bolt : 7.02 kN