SP1xxx: Feed

AC Frequency Display DFU

Displays the AC frequency for fusing temperature control.


1902* [0 to 1/0/1 Step]
Used to check the measured number of interrupts for the zero cross signal.
Measured time interval is 500 ms with 5 interrupts per 2 mms:
10 ms x 50 = 500

1903* Feed Clutch Re-energize

Adjusts the paper feed amount allowed by the clutch after correcting the
skew at registration. When paper jams occur after restarting paper feed after
registration, increase the value to help the registration roller feed the paper.

1 By-pass Feed [0 to 10 / 6 / 1 mm/step]

2 Tray 1 Feed
[0 to 10 / 0 / 1 mm/step]
3 Other Trays

1907* Timing Adjustment DFU

Service
Tables
1908 F1 Plate Adj Upper Tray: Main Machine (Standard)

1909 F2 Plate Adj Lower Tray: Main Machine (Standard)

1910 F3 Plate Adj Upper Tray: PTU (Option)

1911 F4 Plate Adj Lower Tray: PTU (Option)

These SP codes adjust the initial amount of pressure that the bottom
plate exerts on the bottom of the stack that presses against the feed
roller. Adjust these SP codes if the machine is consistently
double-feeding or failing to feed a specific paper size.
These SP codes adjust the length of time that the lift motor runs forward
or reverse to raise or lower the bottom plate under the stack after the top
of stack has reached the feed position.
Double feeding occurs when there is too much pressure. To

SM 5-17 D017/D018/D019/D020
SP1xxx: Feed

correct this, increase the length of time the motor runs in


reverse to lower the tray (to do this, reduce the value of the
setting).
Failure to feed occurs when there is not enough pressure. To
correct this, increase the length of time the motor runs forward
to raise the tray. (to do this, increase the value of the setting).
How to Read These SP Codes
Each selection shows the paper size and a percentage that
indicates the amount of paper remaining in the tray when the
setting will take effect. For example, "B4,LG 70%" means the
setting will take effect when B4 or Legal size paper is loaded in
the tray and 70% of the paper remains in the tray.
The "Initial" notation in the display indicates the default value for
the setting. A positive number (+) indicates the length of time
(ms) the lift motor runs forward to raise the bottom plate and
increase pressure. A negative number (-) indicates the length of
time (ms) the lift motor runs in reverse to lower the bottom plate
and reduce pressure.
Please note that the "Initial" settings for some settings are
negative (reverse run time), others are positive (forward run
time).
Note: Before doing any adjustments with these SP codes, confirm that
the correct paper size has been selected for each tray with SP codes
1912, 1913, 1914, 1915.

1 A3, DLT:100% To correct feed problems for a paper size, be


sure to set all four settings (100%, 70%,
---
30%, 10%) for each paper size that is
causing problems.
The "T" notation denotes "SEF" (Short Edge
56 A5T:70%->30% Feed).
The "Y" notation denotes "LEF" (Long Edge
Feed)

1912 Tray 1: Auto Paper Size Detection

D017/D018/D019/D020 5-18 SM