Measurement to Perfection... ‘Main Bld. Premises : Centenary Building (G.Fir), Door No, At :100, W Park Rd. Between Sampighe Road And Margosa Rd, 40th Crs, Malleswaram, Bangalore City, Pin~560003 ©C-2231 NABL Accredited Calibration Lab as per ISO/IEC 17025 : 2005 CALIBRATION CERTIFICATE Customer Name & Address : M/s. ‘Sandvik Asia Private Ltd., Plot No.: 49 & 498, Sipcot Industrial Complex, Hosur - 635 126. Tamil Nadu, Customer's Reference SRF No: TSCi-10035 Dated :20Nov 2017 GAL CERT. NO, CALIBRATED ON | RECOMMENDED CAL DUE PAGE NO. TSOnT 9809642 20Nor 2007 20 May 2018 132 Detalls of device under eatration (0UC): DUG: Aniog Pressure Gauge a af Pages z take Baumer Clbration Prowadio TST Hose BUG Recaied 20 Row 2017 Si No T57SBGTOSS BUG Condon on Rassgt Sates [No cal casio Tecaton mas Environmental Conditions: Temperature in'C 25.8 Humidity in RH% : 66 standards used: S.No] Nomenciure [ware a nous] s.No | Accuaeys | Traceable totcentieate ne. | vatay aap 1 [Pressure mdeatr| imatments& | yyE%C., | cosy [anes ATSCNE-TINAMEC 26 ny 2047 ero40 207201; Note: 1. The Calibration Certificate relates only to the above DUCBReported results are Valid at the time of and under the stated conditions of measurements, 2. Partial Publication’ reproduction of this Certificate in any form is not permitted without the written consent of Transcal. ‘3, Errors if any;in this Certificate shall be brought to notice within 45 days from the date of this Certificate 4, Measurement Uncertanity reported is at approximately 95 % confidence level with k=2;Units of Measurement results & Measurement Uncertanity are same as that of range selected-Unless otherwise indicated. 6. Calibration of the DUC are traceable to National/International Standards 6. Corrections/erasing,invalidate the Calibration Certficate-exception to the"Final Page or Part ofthis Report-provided for incorporation of additional data(To be filled by customer authorized signatory and not under calibration laboratory control) 7. In Result Sheets, "PASS"indicates measured readings are within specification limit,"Fail"indicates measured readings are ut of specification limit&"-"indicates no specification limit furnished, 8. Consider Model or Range whichever is applicable ' NABL-13S guideliness are adopied for use of NABI Symbol Si a . a * ( sancnone) * z(RSam5) 2) shone % US 7 (Lab - Incharéa) Calibrafha By Checked By Sridhbr C.N (Sr. Calibration Enaineert CAL GERT.NO. _ TSC/17-18/8035-42 Page No. 2 of 2 Results : Range 0010 _kglom? Le 0.1 kglem? Accuracy : # 1.0 % of FSD sine [Reed inf | roars] Denton bar | eaurement | remarks | Remaris RO ease | rl sen Up Ba oer ASE teed ce 4 0.0 0.000 0.000 | 0.000 0.000 0.000 _- 2 20 1.961 1.962 1.960 | -0.001 0.001 1.444 Pass Pass 3 3.0 2.942 2.945 | 2943 | -0.003 0.001 1.059 Pass Pass: eas oe |e oo 5 5.0 4.903 4.909 | 4.907 | -0.006 ~0.004 0.541 Pass Pass 6 6.0 5.884 5.891 5.890 | -0.007 0.006 0.455 Pass Pass: 7 7.0 6.865 6.875 6.874 | -0.010 ~0.009 0.395 Pass Pass: 8 8.0 7.845 7.857 7.856 | -0.012 -0.011 0.350 Pass Pass: 9 10.0 9.807 9.820 9.820 | -0.013 0.013, 0.290 Pass Pass ‘Conclusion Remarks Measurement Uncertainty reported is at coverage factor k = 1.96 which corresponds to a confidence level of 1) 95.%. Measurement Uncertainty includes accuracy of the standard, standard instrument uncertainty, Resolution of DUC, Hysteresis, Zero drift and Repeatability. 2) Calibration done as per DKD-R6-1 3) Accuracy mentioned as per customer request. 4) Certificate issued is only for scientific and industrial purpose only. horised By fi

You might also like