You are on page 1of 5
Mi EC type-approval certificate Number T7475 revision 2 Project number 10200578 Page 1 of 5 Issued by NNMiCertin B.V. Hugo de Grootplein 1 3314 EG Dordrecht The Netherlands In accordance _ The Council Directive 2009/23/EC on non-automatic weighing instruments. with Manufacturer Shanghai Teraoka Electronic Co., Ltd. Tinglin industry Developmental Zone Jin Shan District Shanghai 201505 Peoples Republic of China Inrespect of Aclass @D, electronic, single- or multi-interval, non-automatic weighing instrument, intended to be used for direct sales to the public. Manufacturer mark/name: Teraoka Type 1 DS-781, DS-781SS, DS-782 Characteristics 3 kg < Max < 30 kg ns for single-interval 11 < 3000 divisions (per partial weighing range) for multi-interval Maximum of 2 partial weighing ranges Ts -¥2 Max for single-interval instruments Ts -Max, - e; for multi-interval instruments Temperature range -10°C/ +40 °C In the description number 17475 revision 2 further characteristics are described. Valid until 17 October 2018 Description and The instrument is described in the description number 77475 revision 2 and documentation documented in the documentation folder 17475-2, appertaining to this EC type-approval certificate. Remarks revision EC type-approval certificate replaces the earlier versions, including its documentation folder. The Notffdd Body no. 0122 i July 2010 ttc, asm tarmaon berm cin Recerton’ SEMEN acne, Retesancaan ZN Tales Rayeetnenaedancipn en MeM eferaccuo ot wet) Ww IN woe Faia sare mecntiegete INSPECTION cmon AVA 122 = Description Number 17475 revision 2 Project number 10200578 Page 2 of 5 1 General information about the non-automatic weighing instrument All properties of the non-automatic weighing instrument, whether mentioned or not, may not be in conflict with the legislation. 1.1. Essential parts See the drawings: = DS-781 Block Diagram, drawing number DS-781 BD1; =__DS-782 Block Diagram, drawing number DS-782 BD1; The electronics; The mechanical assembly with load cell. EMC protection measures, for all models: = The AD board is shielded with a metal cover; = Ferrite coil on cable from: + Mainboard to RS232 connection (4 turns); - Mainboard to display (2 turns); - AID board to mainboard (7 turns); Additional EMC protection measures specific to DS-781 and DS-7815S: ~ Ferrite coil on cable from: = Mainboard to DC jack (11 turns); = Loadcell to A/D board (3 turns); Additional EMC protection measures specific to DS-782: = Ferrite coil on cable from: + Mainboard to battery (2 turns); + Transformer to power plug (13 turns); = Powerplug grounding (13 turns); = Mainboard to transformer (8 turns); - Mainboard to ground (2 turns); = Loadcell to A/D board (two coils of 3 and 4 turns); 1.2 Essential characteristics Power supply: - For DS-781 and DS-7815S: - Adapter input: 220 - 240 VAC output: 5 - 9 V DC; = Batteries 4x15 - For DS-782: = 220V-240VAC, 50/60H2; ~ Rechargeable battery 6 V DC; 1.3. Essential shapes The non-automatic weighing instrument is built according to the drawings: = DS-7818 Exploded view, drawing number TAS-1316; = _DS-781P Exploded view, drawing number TAS-1317; = DS-7828 Exploded view, drawing number TAS-1318; - _DS-782P Exploded view, drawing number TAS-1319; - _DS-7815S Exploded view, drawing number TAS-1428. Mi Description Number 17475 revision 2 Project number 10200578 Page 3 of 5 The data plate is secured against removal by sealing or will be destroyed when removed. To secure components that may not be dismantled or adjusted by the user, the non-automatic weighing instrument has to be secured in a suitable manner on the locations indicated in the drawing: = _ DS-7818/7828 Sealing position, drawing number TAS-1320; = _DS-781P/782P Sealing position, drawing number TAS-1321; = _DS-7815S Sealing position, drawing number TAS-1429. Inside the cabinet is a calibration lock, located on the main board. 1.4 Conditional parts The non-automatic weighing instrument may be equipped with peripheral equipment which is used for the applications listed in article 1(2)(a) of Directive 2009/23/EC, if the peripheral equipment is Certified to be connected to an EC type-approved non-automatic weighing instrument by a Notified Body responsible for type examination under Directive 2009/23/EC. The non-automatic weighing instrument may be equipped with an Electronic Point of Sale (EPoS) or an Electronic Cash Register (ECR), if these EPOS and ECR are certified to be connected to an EC type-approved non-automatic weighing instrument by a Notified Body responsible for type ‘examination under Directive 2009/23/EC. The non-automatic weighing instrument may be equipped with Electronic Funds Transfer equipment (EFT/ECU), if these EFT/ECU represent only the price total on the display. The non-automatic weighing instrument is fitted with a levelling device and a level indicator, unless the instrument is installed in a fixed position. The level indicator has a sensitivity of at least 2 mm for a tilt of 2/1000. 1.5 Non-essential parts Battery; ACIDC-adapter. a5 Description Number 17475 revision 2 Project number 10200578 Page 4 of S 2 Information about the main constituent parts of the non-automatic weighing instrument The electronics 2.1.1 Essential parts Drawing number cPs2119 Lay-out PLs2119 Parts list (1 page) cps2i25 Lay-out PLS2125 Parts list (1 page) cPs2120 Lay-out PLs2120 Parts list (1 page) 2.1.2 Essential characteristics List of devices: = Determination stability of equilibrium; = Zero indicator; = Semi-automatic zero-setting; ~ Initial zero-setting; = Zero-tracking; ~ Semi-automatic subtractive tare balancing: - Indication of stable equilibrium; = Calibration mode via a switch on the main board; = Acting upon significant faults; - Checking the display; = Check weighing mode; = Price calculation; - PLU function. 2.1.3 Conditional parts The interface section is located on separate interface boards. The non-automatic weighing instrument may be equipped with one or more of the following protective interfaces that have not to be secured: = _ RS232C (not for DS-78155). Mi Description Number 17475 revision 2 Project number 10200578 Page 5 of 5 2.1.4 Non-essential parts The non-automatic weighing instrument may be connected to non-essential devices, for example but not limited to bar code readers, foot switches, second display's and cash drawers, provided that: = They do not present primary data used for purposes mentioned in article 1(2)(a) of Directive 2009/23/EC unless the "preliminary observations" in Annex 1 of this directive is satisfied; - They do not lead to an instrument having other essential characteristics than those fixed by this type-approval document. Display; Keyboard, 2.2 The mechanical assembly with load cell 2.2.1 Essential parts Drawing number DS-7818/782B Loadcell assembly TAS-1322 DS-781P/782P Loadcell assembly TAS1323, DS-781SS / DS-7885S Load cell assembly TAS1432 Loadcell specification sheet LC-JS Los 2.2.2 Essential characteristics © > Ena/11500, oF €, > Emy/11500 in case of multi-interval instrument; Excitation power supply 5 V DC. 2.2.3 Essenti shapes See drawings: 3 Approval conditions See chapter 1.3, essential shapes. 4 Seals and verification marks See chapter 1.3, essential shapes. 5 CE-mark of conformity and inscriptions The marks, facilities for the marks and the inscriptions on the non-automatic weighing instrument fulfill the requirements of article 1 of Annex IV of Directive 2009/23/EC.

You might also like