1 25/4/2017 PCR AJB PCR_AJB_1_25/4/2017_3G2_BULAKPULANG_TB3_70_50 BULAKPULANG_TB 3G2_BULAKPULANG_TB3


2 26/4/2017 PCR AJB PCR_AJB_2_26/4/2017_U_WRINGINGHARJO_MT3_60_40 WRINGINGHARJO_MT U_WRINGINGHARJO_MT3
3 26/4/2017 PCR AJB PCR_AJB_3_26/4/2017_3G_PUCUNGKROYA_TB1_80_60 PUCUNGKROYA_TB 3G_PUCUNGKROYA_TB1
4 26/4/2017 PCR AJB PCR_AJB_4_26/4/2017_U_BINANGUNCLP_TB1_80_60 BINANGUNCLP_TB U_BINANGUNCLP_TB1
5 26/4/2017 PCR AJB PCR_AJB_5_26/4/2017_U_BINANGUNCLP_TB2_70_50 BINANGUNCLP_TB U_BINANGUNCLP_TB2
6 26/4/2017 PCR AJB PCR_AJB_6_26/4/2017_U_WIDARAPAYUNG_MT1_70_50 WIDARAPAYUNG_MT U_WIDARAPAYUNG_MT1
7 28/4/2017 PCR AJB PCR_AJB_7_28/4/2017_U_MUJUR_PS3_80_60 MUJUR_PS U_MUJUR_PS3
8 29/4/2017 PCR AJB PCR_AJB_8_29/4/2017_U_KERTEKWONOSOBO1_50_30 KERTEKWONOSOBO U_KERTEKWONOSOBO1
9 29/4/2017 PCR AJB PCR_AJB_9_29/4/2017_U_KERTEKWONOSOBO3_70_60 KERTEKWONOSOBO U_KERTEKWONOSOBO3
10 29/4/2017 PCR AJB PCR_AJB_10_29/4/2017_U_SINUNGREJO_RT1_50_40 SINUNGREJO_RT U_SINUNGREJO_RT1
11 29/4/2017 PCR AJB PCR_AJB_11_29/4/2017_U_SINUNGREJO_RT3_50_30 SINUNGREJO_RT U_SINUNGREJO_RT3
12 29/4/2017 PCR AJB PCR_AJB_12_29/4/2017_U_BANJARNEGARA3_70_60 BANJARNEGARA U_BANJARNEGARA3
13 29/4/2017 PCR AJB PCR_AJB_13_29/4/2017_U_BUMIREJO_TB1_20_40 BUMIREJO_TB U_BUMIREJO_TB1
14 2/5/2017 PCR AJB PCR_AJB_14_42771_3G_BANJARNEGARA3_60_50 BANJARNEGARA 3G_BANJARNEGARA3
15 2/5/2017 PCR AJB PCR_AJB_15_42771_U_BANJARNEGARA3_60_50 BANJARNEGARA U_BANJARNEGARA3
Tilt Afer(0.1degree)
Tilt(0.1degree)
Subunit Name
Subunit No.
Device No.

SCRIPT
7 1 RET_U2100_S3 70 50 MOD RETSUBUNIT:DEVICENO=7,SUBUNITNO=1,TILT=50;
6 1 RET_U900_S3 60 40 MOD RETSUBUNIT:DEVICENO=6,SUBUNITNO=1,TILT=40;
2 1 RET_U2100_S1 80 60 MOD RETSUBUNIT:DEVICENO=2,SUBUNITNO=1,TILT=60;
0 1 RET_U900_S1 80 60 MOD RETSUBUNIT:DEVICENO=0,SUBUNITNO=1,TILT=60;
3 1 RET_U900_S2 70 50 MOD RETSUBUNIT:DEVICENO=3,SUBUNITNO=1,TILT=50;
0 1 RET_U900_S1 70 50 MOD RETSUBUNIT:DEVICENO=0,SUBUNITNO=1,TILT=50;
6 1 RET_U900_S3 80 60 MOD RETSUBUNIT:DEVICENO=6,SUBUNITNO=1,TILT=60;
0 1 RET_U900_S1 50 30 MOD RETSUBUNIT:DEVICENO=0,SUBUNITNO=1,TILT=30;
6 1 RET_U900_S2 70 60 MOD RETSUBUNIT:DEVICENO=6,SUBUNITNO=1,TILT=60;
0 1 RET_U900_S1 50 40 MOD RETSUBUNIT:DEVICENO=0,SUBUNITNO=1,TILT=40;
6 1 RET_U900_S2 50 30 MOD RETSUBUNIT:DEVICENO=6,SUBUNITNO=1,TILT=30;
6 1 RET_U900_S2 70 60 MOD RETSUBUNIT:DEVICENO=6,SUBUNITNO=1,TILT=60;
0 1 RET_U900_S1 20 40 MOD RETSUBUNIT:DEVICENO=0,SUBUNITNO=1,TILT=40;
7 1 RET_U2100_S3 60 50 MOD RETSUBUNIT:DEVICENO=7,SUBUNITNO=1,TILT=50;
6 1 RET_U900_S3 60 50 MOD RETSUBUNIT:DEVICENO=6,SUBUNITNO=1,TILT=50;
Reason
FALLBACK
MOD RETSUBUNIT:DEVICENO=7,SUBUNITNO=1,TILT=70; Complaint
MOD RETSUBUNIT:DEVICENO=6,SUBUNITNO=1,TILT=60; Low traffic, improve revenue
MOD RETSUBUNIT:DEVICENO=2,SUBUNITNO=1,TILT=80; Low traffic, improve revenue
MOD RETSUBUNIT:DEVICENO=0,SUBUNITNO=1,TILT=80; Low traffic, improve revenue
MOD RETSUBUNIT:DEVICENO=3,SUBUNITNO=1,TILT=70; Low traffic, improve revenue
MOD RETSUBUNIT:DEVICENO=0,SUBUNITNO=1,TILT=70; Low traffic, improve revenue
MOD RETSUBUNIT:DEVICENO=6,SUBUNITNO=1,TILT=80; Low traffic, improve revenue
MOD RETSUBUNIT:DEVICENO=0,SUBUNITNO=1,TILT=50; Low traffic, improve revenue
MOD RETSUBUNIT:DEVICENO=6,SUBUNITNO=1,TILT=70; Low traffic, improve revenue
MOD RETSUBUNIT:DEVICENO=0,SUBUNITNO=1,TILT=50; Low traffic, improve revenue
MOD RETSUBUNIT:DEVICENO=6,SUBUNITNO=1,TILT=50; Low traffic, improve revenue
MOD RETSUBUNIT:DEVICENO=6,SUBUNITNO=1,TILT=70; Low traffic, improve revenue
MOD RETSUBUNIT:DEVICENO=0,SUBUNITNO=1,TILT=20; Complaint
MOD RETSUBUNIT:DEVICENO=7,SUBUNITNO=1,TILT=60; Low Signal
MOD RETSUBUNIT:DEVICENO=6,SUBUNITNO=1,TILT=60; Low Signal