PROCEDURE FOR D/G FUEL OIL C/O FROM

Work Instructions WI-E-C304 Rev.No.1 1/1


HFO/LSFO TO LSGO/LSMGO IN EUROPE PORT
Issue Date:01/01/2010 Prepared By: C/E Approved By: To:All Engine Crew member

C304. PROCEDURE FOR D/G F.O C/O FROM HFO/LSFO TO


LSGO/LSMGO(>0.10%S) IN EUROPE PORTS/ANCHORAGE
CHANGE OVER FROM HFO /LSFO TO LSGO/LSMGO

1. 2HOURS BEFORE ARRIVAL /BERTHING TO EUROPE PORTS/ANCHORAGE


2. ENSURE NO.2 D.O (LSGO/LSMGO >0.10%S) SERVICE TANK VALVE
OPENED (DO-660VT)
3. IN ECR CHANGE DIESEL GENERATOR VISCOSITY CONTROLLER FROM VISCOSITY MODE
TO TEMPERATURE CONTROL MODE,
4. REDUCE THE TEMPERAURE OF FUEL OIL GRADUALLY AT THE RATE OF
2~5 DEG. C PER MINUTES USING TEMPERAURE REGULATOR,
5. ALLOW THE TEMPERAUTRE OF THE FUEL OIL TO DROP 90 ~ 80 DEG.C
6. CHANGE OVER D/G CONSUMPTION TO D.O USING CHANGE OVER SWITCH
PROVIDED IN THE ECR,
7. ENSURE THAT THE D/G CONSUMPTION CHANGED OVER FROM HFO/LSFO TO
D.O SIDE BY CHECKING THE THREE WAY VALVE POSITION OR INDICATION
IN THE ECR,
8. NOTE DOWN D/G D.O FLOW METER READING, TIME AND POSITION OF SHIP
9. ENSURE D/G FUEL OIL PRESSURE AND OPERATIONAL PARAMETERS
ARE NORMAL

CHANGE OVER FROM LSGO/LSMGO TO HFO/LSFO

AFTER DEPARTURE FROM THE PORT AND WHEN SOP IS GIVEN

1. USING D/G VISCOSITY CONTROLLER, TEMPERATURE CONTROL MODE


REDUCE THE D/G FUEL OIL CIRCULTING TEMPERATURE TO
80~90 DEG. C
2. USING CHANGE OVER SWITCH IN ECR CHANGE D/G CONSUMPTION FROM
D.O TO HFO,
3. CONFIRM D/G CONSUMPTION CHANGE OVER BY THREE WAY VALVE
AND THE INDICATION IN ECR,
4. NOTE DOWN D/G FUEL OIL FLOW METER READINGS, TIME AND
SHIP POSITION,
5. GRADUALLY EFFECT HEAVY FUEL OIL TEMPERATURE AT THE
INLET OF ENGINE AT THE RATE OF 5~10 PER MINUTE, UPTO REQUIRED
FUEL OIL TEMPERATURE REACHED THAT IS NORMALLY 120 ~130 DEG.C
USING VISCOSITY CONTROLLER, TEMPERATURE REGULATOR,
6. CHANGE OVER VISCOSITY CONTROLLER FROM TEMPERATURE MODE
TO VISCOSITY CONTROL MODE AND SET VISCOCITY AT THE ENGINE INLET
13~14 CST
7. CHECK FUEL OIL PRESSURE IS MAINTAINING NORMAL,
8. CHECK EXHAUST UNIT EXHAUST GAS TMEPERTURE AND RUNNING CONDTION
ARE NORMAL

REF. GI/FLT/041/09, CIRCULAR DNV PETROLEUM SERV ICES 29 SEPT.2009


POSTED ECR
DISTRIBUTED TO ALL ENGINE CREW.