3D Model Formats and Files Supported by SmartPlant Interop Publisher 2015R1 and later

Intergraph
Products Version Source Extension Notes/Requirements

CADWorx Plant 2015 .dwg For .dwg files containing proxy objects, the following software is required:
Professional, and or
CADWorx earlier .drv MicroStation V8i and RealDWG 2013 SP1
Equipment  Install and activate MicroStation V8i SS3, and then install
RealDWG 2013 SP1 to translate any proxy objects inside
these files. For normal AutoCAD entities, the presence of
MicroStation is ignored. However, if the file contains at least
one proxy object and MicroStation V8i is installed, translation
is done using MicroStation.
CADWorx Plant 2014 Object Enabler:
 For CADWorx data, you must install the CADWorx Plant 2014
Object Enabler to view CADWorx Plant 2014 components
stored in an AutoCAD drawing (.dwg) file. You can install the
utility from the SmartPlant Interop Publisher DVD (Prerequisite
Software), or go to the Intergraph Smart Support website and
download this executable from CADWorx Freeware Tools and
Utilities.
CADWorx 2015 SP1 allows you to export .drv files that can be translated
to Smart Models for Smart 3D and SmartPlant Foundation target
applications.
SmartPlant Interop Publisher supports AutoCAD 2014 or earlier .dwg
files.

CAESAR II 5.1 - .mdb


2014
SP1
(7.0)
and
later

Isogen® (IDF, 2014 .idf, .pcf, .idf


PCF), SmartPlant R1 and
Spoolgen, earlier
SmartPlant
Isometrics

PDS, V7 Graphics: .dri, .dgn,


FrameWorks® .prp
Plus Data: .drv

Smart 3D (3D 2014 Graphics: .vue Data is translated based on the P3DComponent.xml schema file and the
Model R1 and Data: .xml RelationshipMapping.txt file.
earlier
using
3D
Model
Data
Drawing
Intergraph
Products Version Source Extension Notes/Requirements

Smart 3D v2009.1 Graphics: .vue


SPRDirect and Data: .mdb2
later

Third Party Source


Products Version Extension Notes/Requirements

ACIS - Design ACIS R25 .sat  The size of the SAT file to be translated should not exceed 2
model data from and earlier GB.
products such as  Graphics only.
AutoCAD
Inventor, Creo, JT
Open, Solid Edge,
and SolidWorks

AutoCAD 2014 and .dwg, .dxf MicroStation V8i and RealDWG 2013 SP1 are required for DWG files
earlier containing proxy objects.
 Install and activate MicroStation V8i, and then install RealDWG
2013 SP1 to translate any proxy objects inside these files.

AutoPlant .dwg, .dgn, MicroStation V8i SS3 and RealDWG 2013 SP1 are required for
i.dgn AutoPLANT graphics files.
 Install and activate MicroStation V8i. Then download and install
install RealDWG 2013 SP1 to translate any proxy objects inside
the graphics files.
 Source files must be exported from AutoPlant using the Project
Packager utility.

CATIA V5 (R8– .CATPart, For CATIA V6, you must export your database objects as CATIA V5
R24) and .CATProduct CATParts and CATProducts.
V6 (V6
R2014x). You must have an MCD license and the Intergraph MCAD module
installed with SmartPlant Interop Publisher to translate MCAD source files.
You can set defeaturing options to reduce model complexity. For more
information, see Define Translation Settings (on page Error! Bookmark
not defined.) and Mechanical CAD (MCAD) defeaturing options (on page
Error! Bookmark not defined.).

CIS/2 (design 203, 214 .stp, .step Where possible, we recommend using the IFC format for data exchange.
model data from
products such as For more information on CIS/2 supported entities, see CIS/2 Entities and
SDS/2, StruCAD, Cross-Section Data.
Tekla Structures,
and ProSteel,
among others)

CREO Parametric 16 - Creo .prt, .prt.*, You must have an MCD license and the Intergraph MCAD module
(formerly 3.0 .asm, .asm.* installed with SmartPlant Interop Publisher to translate MCAD source files.
Pro/Engineer),
Siemens You can set defeaturing options to reduce model complexity. For more
information, see Define Translation Settings (on page Error! Bookmark
not defined.) and Mechanical CAD (MCAD) defeaturing options (on page
Error! Bookmark not defined.).

IGES (products 5.3 and .igs, .iges The size of the file to be translated should not exceed 2 GB.
that export IGES) earlier
Graphics only.
Third Party Source
Products Version Extension Notes/Requirements

i-model MicroStati .i.dgn


on V8i
SS3 and
earlier

Industry 2x3_TC1 This is the recommended data exchange format for reading SDS/2, Tekla,
Foundation schema .ifc and Revit projects. SmartPlant Interop Publisher only supports IFC
Classes (IFC) version 2x3_TC1 schema.

Inventor V11 -
2015

MicroStation J V07.01.05. .dgn In the MicroStation Translation Settings, you can turn on the Change
03 SmartSolids to surfaces for V7 DGN files option.
V07.02.00.
00
(Required
for
supporting
Smart
Solids
display)

MicroStation V8: V8.05 .dgn, .dtm MicroStation V8 and later

MicroStation XM V8.09 .dgn, .dtm

MicroStation V8i V8.11.09 .dgn, .dtm MicroStation V8i SS3 and earlier

NX NX 1 - NX .prt You must have the Intergraph MCAD module and MCD license installed
9 with SmartPlant Interop Publisher to translate MCAD source files.
You can set defeaturing options to reduce model complexity. For more
information, see Define Translation Settings (on page Error! Bookmark
not defined.) and Mechanical CAD (MCAD) defeaturing options (on page
Error! Bookmark not defined.).

Parasolid 9.0 – 27.0 .x_t, .xmt_txt, You must have an MCD license and the Intergraph MCAD module
x_b, .xmt_bin installed with SmartPlant Interop Publisher to translate MCAD source files.
You can set defeaturing options to reduce model complexity. For more
information, see Define Translation Settings (on page Error! Bookmark
not defined.) and Mechanical CAD (MCAD) defeaturing options (on page
Error! Bookmark not defined.).

PlantSpace V8.05, .dgn


V8.09, and
V8.11.09

PlantSpace AutoCAD .dwg


2014

PDMS V12.1 and Graphics: .rvm When there is an .att and .datal file, SmartPlant Interop Publisher uses
earlier only the .att file. If the .rvm and .datal are used, not all objects can have
Data: .att/.datal properties. You might have to go back to your PDMS application and
ensure that tags are written for all objects in the .datal file.
Third Party Source
Products Version Extension Notes/Requirements

ProStructures v8i .dwg, .dgn, .dxf MicroStation V8i SS3 and the ProStructures v8i SELECTseries 6 plugin
SELECTs are required for ProStructures graphics files.
eries 6
 Install and activate MicroStation V8i. Then download and install
ProStructures v8i SELECTseries 6 plugin to translate any proxy
objects inside the graphics files.

Solid Edge V18 - ST7 .par, .asm, You must have an MCD license and the Intergraph MCAD module
.psm installed with SmartPlant Interop Publisher to translate MCAD source files.
You can set defeaturing options to reduce model complexity. For more
information, see Define Translation Settings (on page Error! Bookmark
not defined.) and Mechanical CAD (MCAD) defeaturing options (on page
Error! Bookmark not defined.).

SolidWorks 2003 - .sldprt, .sldasm You must have an MCD license and the Intergraph MCAD module
2014 installed with SmartPlant Interop Publisher to translate MCAD source files.
You can set defeaturing options to reduce model complexity. For more
information, see Define Translation Settings (on page Error! Bookmark
not defined.) and Mechanical CAD (MCAD) defeaturing options (on page
Error! Bookmark not defined.).

Speedikon, Tribon MicroStation MicroStation V8i SS3 and RealDWG 2013 SP1 are required. MicroStation
M2 / M3 .dgn v8i SS3 must be installed and activated.

Tekla , StruCAD, IFC: .stp, .step, .ifc For more information on CIS/2 supported entities, see CIS/2 Entities and
Xsteel, SDS/2, 2x3_TC1 Cross-Section Data.
Autodesk Revit, schema
RAM Steel, version We recommend using the IFC format for data exchange.
ETABS, To find the schema version of an .ifc file, open the file in any text editor
SAP2000, RISA- such as Windows Notepad, and check the FILE_SCHEMA version listed
3D, Advance in the File Header section. For IFC files that are supported by SmartPlant
Steel, GT Interop Publisher, the File Header has the FILE_SCHEMA(('IFC2X3'));
STRUDL, entry. For more information, see Translate IFC source files (on page
STAAD.Pro, Error! Bookmark not defined.).
ProSteel

XMpLant .xml Supports xml files that have the root node as "PlantModel".

 For ACIS and IGES files, the .drv and .mdb2 files generated by SmartPlant Interop Publisher during
translation are created with empty label data. This can also apply to MicroStation V7 .dgn files that do
not have tag data.
 Both SmartPlant Review and Smart 3D target applications require licenses from Leica, Z+F or
Quantapoint to display laser data.
 SmartPlant Interop Publisher does not support .dtm files created with Inroads.
 SmartPlant Interop Publisher does not support non-uniform scaling.

For more information visit: http://www.intergraph.com/go/SPIOP