You are on page 1of 56

CAT 6A

Reference Guide
Thank you for choosing Leviton Network Solutions. Our copper, fiber, power, and
Connected Home solutions are ideal for today's most demanding applications,
consistently exceeding our customers’ expectations. Leviton CAT 6A structured
cabling solutions are no exception. UTP eXtreme® 6A channel- and component-rated
performance options plus a shielded solution meet the needs of any application.
Our component-rated UTP CAT 6A connectivity solution is the first in the industry to
achieve third party verification through Intertek/ETL. Our channel-rated UTP solution
balances economy with Leviton performance. And shielded connectivity delivers the
signal isolation and data security essential in government, gaming, medical,
and financial installations.
UNDERSTANDING CAT 6A DATA CENTER APPLICATIONS
CH 02 Standards
CH 24 Pathways & Spaces
1 5
03 Leviton CAT 6A Expertise 25 New CAT 6A DC Solutions
TABLE OF CONTENTS

05 Leviton CAT 6A Systems


CAT 6A TERMINATION
HORIZONTAL CABLING 28 Tips
CH 08 CAT 6A Cable Types CH
29 110-Style Patch Panels
2 09 Routing & Handling 6
31 UTP Connectors
11 Pathways & Spaces 33 Shielded Connectors
TELECOMMUNICATIONS ROOM CAT 6A TESTING
14 Patch Panels CH
CH 7 36 Performance Tests
3 15 Cable Management Products 37 AXT Testing
17 Cable Assemblies
18 Managing Cords CH
8 39 LEVITON PART NUMBERS
WORK AREA 43 GLOSSARY
CH 20 Cabling CH
4 9
21 Workstation
1. INTRODUCTION

Understanding CAT 6A
Equipment, design and planning, and installation practices for CAT 6A
projects are all significantly different from previous generation structured
cabling systems. Use this guide to gain a better understanding of these
unique requirements, which will in turn help you accurately bid jobs and
shorten installation time. The final result will be a high-performance
system that supports today’s requirements and provides a smooth
migration path toward 10G network performance.
CH. 1 The Category 6A Organization: Organization: Organization:
INTRO (Augmented Category 6) TIA (Telecommunications ISO (International Standards IEEE (Institute of Electrical and
standard addresses the Industry Association) Organization) Electronics Engineers)
performance demands Standard: Standard:
Standard:
of 10 Gigabit Ethernet 11801; Class EA Specification 802.3an
568-C.2 (replaces 568-B.2-10)
(10GBASE-T). Several
organizations detail Defines: Defines: Defines:
Performance requirements for Class EA cabling and component Channel performance for

leviton.com/cat6a | 800.722.2082
aspects of the standard,
STANDARDS

but all define 6A CAT 6A channels, permanent performance requirements 10GBASE-T Ethernet over
performance as up to links, and components for customer premises. ISO balanced twisted pair cables
500 MHz and a maximum equivalent of CAT 6A; commonly
distance of 100 meters specified outside of North America
(328 feet). CAT 6A is
backward compatible
with CAT 6, 5e, 5, and
3 performance and
applications.
2
CH. 1 Technical Support & Applications Engineering
INTRO When you need assistance with your next CAT 6A project, from selecting the
best products for an application to tips on building or installing a system,
LEVITON CAT 6A EXPERTISE
contact our technical support team. Team members have extensive training on
CAT 6A standards and applications, and can help work through your questions
as you complete your first 10G installations.
Leviton’s expert team of applications engineers provides CAT 6A infrastructure
design assistance. Each design is built around the specific needs of your
active equipment, network topology, and transmission methods. The unique
requirements of facilities such as data centers, government agencies,
health care facilities, and high-rise structures are also incorporated. Just as
important, the team utilizes its thorough understanding of industry standards
and product functionality to plan systems that will accommodate industry
trends and future needs.
Call 800.824.3005 or +1.425.486.2222 or email appeng@leviton.com for
technical support or applications engineer assistance.

3
CH. 1
Leviton Contractor Program Specification Support
INTRO
For guaranteed product performance, choose a Leviton Contractor Leviton’s nationwide team of specification engineers supports
Program installer. The program builds on contractor experience consultants, architects, specifiers, and engineers who design
LEVITON CAT 6A EXPERTISE

and knowledge to ensure quality installation of Leviton Network network systems. All team members hold BICSI’s RCDD
Solutions products. Program installers attend Leviton’s training certification, and are members of the Construction Specifications
course, which includes the latest structured cabling standards, Institute. These engineers thoroughly understand the demands
industry technologies, installation techniques, and field-testing placed on different network environments, and specify only
methods. Most importantly, they offer more value to their the equipment that will provide optimal performance in each

leviton.com/cat6a | 800.722.2082
customers with a lifetime product and performance warranty on installation. In addition, Leviton offers direct field support and
qualified projects. materials for use in bids, design plans, RFPs, and specification
Visit leviton.com/lcp or email contractorprograms@leviton.com documents, including BIM (building information modeling) objects,
for more information. CAD drawing files, Visio stencils, and bid spec/RFP documents.
Visit leviton.com/specteam or email specteam@leviton.com for
more information.

Contractor Program
4
CH. 1 Channel-Rated UTP System Component-Rated UTP System Shielded System
INTRO All category-rated solutions are channel Leviton’s component-rated system delivers Like our CAT 6A UTP solutions, Leviton’s
rated, meaning that the end-to-end industry-leading performance for today’s shielded solutions exceed CAT 6A
LEVITON CAT 6A SYSTEMS

system has been tested to perform at high bandwidth applications. Component- performance standards and protect
or above its standard’s requirements. rated performance is more stringent than network traffic from alien crosstalk.
Leviton’s channel-rated system balances channel-rated; each connectivity element Our shielded solutions offer a high level of
economy with Leviton quality and is guaranteed to meet or exceed the data security and EMI/RFI protection for
performance. Our exclusive Cone of standard’s performance. To provide greater government, healthcare, gaming, financial,
Silence® helps suppress alien crosstalk, a headroom in high-density and short-link manufacturing, and other sensitive
dual layer wiring scheme label simplifies installations, Leviton has designed and environments. With shielding, internal
termination, and patented Retention Force engineered a component-rated CAT 6A data signals are securely contained and
Technology protects against damage from connector with patent-pending triple-stage isolated from interference.
four- or six-pin plugs. compensation. An advanced rigid circuit
board design, engineered tine geometry,
and a flexible circuit provide compensation
to minimize the adverse effects of return
loss, near end crosstalk, and alien crosstalk.

5
CH. 1 UTP Channel- &
INTRO Component-Rated
• QuickPort® connectors
LEVITON CAT 6A SYSTEMS

• SlimLine patch cords


• 110-style patch panels
• QuickPort patch panels
• 110-style wiring blocks

leviton.com/cat6a | 800.722.2082
Shielded
• Die-cast QuickPort connectors
• SlimLine patch cords
• QuickPort patch panels

6
2. HORIZONTAL CABLING

CAT 6

CAT 6A

CAT 6A cable is considerably different from previous generation cable.


Its larger outside diameter (OD), corresponding larger minimum bend radius,
and heavier weight will change installation requirements for routing and
handling as well as design of pathways and spaces.
How is CAT 6A Cable Unique?
• TIA standard allows up to .354" outside diameter (OD), a 54% increase over
CAT 6 OD average of .23"
• More than twice the weight of typical CAT 6 cable
• Tighter twists and larger conductor size than CAT 6 and 5e
• Typically comes on large reels and requires special reel-handling equipment
CAT 6A Cable Types

Maximum Horizontal

TECH TIP
1st Generation 2nd Generation Shielded Cable Distance
UTP UTP TIA specifies 90 meters
1st Gen 2nd Gen shielded
1st Gen 2nd Gen 1stshielded
Gen 2nd Gen shielded (295 feet) as the maximum
Most 1st generation UTP cable 2nd generation UTP cable also has Shielded cable provides higher permanent link length and
is designed and manufactured tighter twists and larger conductors immunity to EMI/RFI and has a

leviton.com/cat6a | 800.722.2082
100 meters (328 feet) for
with tighter twists, larger than CAT 6, but incorporates new smaller OD, typically .29" - .32". maximum channel length.
conductor size, and more cable design elements such as filler However, the cable has a drain The standards do not specify
complex center splines tubes or non-conductive isolation wire and foil shield that will a minimum length, but 10
than CAT 6 cable. These wraps that allow a smaller cable increase installation time. In feet is recommended to avoid
characteristics increase cable OD while retaining 6A performance. addition, every component in return loss and NEXT issues
OD and result in heavier cable 2nd generation cable is lighter and the system must be shielded due to the higher signal
weight, reduced fill capacity, offers better performance with a and properly bonded to ground frequency. Leviton is the only
manufacturer to provide lifetime
and a larger bend radius. smaller bend radius. in order to be effective.
warranty coverage on qualified
installations for a 10 foot
Cable Type 5e 6 6A Gen1 6A Gen2 6A Shielded 6A Max permanent link, critical in data 8
center applications.
Average OD .185" .230" .330" .300" .290" .354"
CH. 2 Larger, heavier CAT 6A cables require Cable Reels Cable Pulling
modifications to traditional cable
HORIZ. Typically, CAT 6A cable will come on The maximum pulling tension for a
CABLING routing and handling techniques.
reels instead of in pull boxes and will 4-pair balanced twisted pair cable must
Follow the tips here to help ensure a require racks/carts that can support not exceed 25 lbf (110N). Exceeding
smooth installation. their larger size. this tension will result in transmission
ROUTING & HANDLING

degradation and may affect the system’s


ability to pass certification testing.

Leviton VELCRO® Brand Fasteners

SPOTLIGHT
Use Leviton's VELCRO® Brand
fasteners to secure all cable bundles.
Our genuine VELCRO® Brand products
won’t crush or damage cables like
tie wraps can, and are reusable for
moves, adds, and changes.
DO DON'T 9
CH. 2 Bend Radius Placement
HORIZ. To maintain CAT 6A performance, minimum bend radius Leviton approved-partner CAT 6A cable may be placed in the same
CABLING
should exceed 4x OD for UTP and shielded cable. This radius tray with CAT 6, 5e, and other category-rated cables. In addition,
is significantly larger than CAT 6 and 5e. Plan carefully to Leviton warrants its product performance whether strict combing or
ensure there is sufficient space throughout cable runs to randomizing dressing methods are used. As with all cable runs, large or
ROUTING & HANDLING

maintain proper bend radius. heavy cable bundles should be positioned under other cable to prevent
Note: In 568-B.2-10, CAT 6A shielded cable bend radius was 8x OD. crushing. Follow NEC code for separating power and data cables.

leviton.com/cat6a | 800.722.2082
Slack Loops
TIA recommends storing 10 feet of extra cable in Pulling Lubricants

TECH TIP
the telecom room and 12-18 inches above work area To maintain CAT 6A performance, choose spray or wipe
installations for re-terminations and to accommodate lubricants specifically designed for data communications
moves, adds, and changes. Use an extended or figure 8 cables. Using other lubricants can degrade performance;
the majority of insertion loss failures have been traced
loop configuration to alleviate cable stress. Cable slack in
back to the use of general purpose lubricants.
bundled or excessive loops has been shown to degrade
cable performance and is associated with return loss 10
failures. Plan carefully to ensure there is sufficient space
and support for heavy CAT 6A cable slack loops.
CH. 2 Cable Tray Fill Structural & Cable Supports
HORIZ. TIA-569 recommends 25% fill at initial installation and up to 50% with unplanned additions. • Stronger anchors and threaded
CABLING
If a single cable tray will also carry power cables, a physical barrier is required to comply with rods are needed to support heavier
the NEC. Finally, ensure tray support spacing is sufficient to prevent excessive sagging. CAT 6A cable
Consider solid bottom tray for higher density applications. • Use properly sized J hooks and
PATHWAYS & SPACES

other supports to accommodate


Conduit Fill Typical Tray & Conduit Capacity (# of cables) bundle size
• Limit bundles to 50 cables to prevent
A maximum conduit fill ratio 5e 6 6A1 6A2 6AS
damage to cables on the bottom
of 40% is recommended Average OD .185" .230" .330" .300" .290"
by TIA-569 standards to 2" x 6" 111 72 35 42 45 • Do not exceed cable support

Cable
manufacturer’s recommended

Tray*
accommodate cable bundle 4" x 8" 298 192 93 113 121
bend radius requirements and 6" x 20" 1116 722 350 424 454 capacity
allow for future expansion. 3/4 6 5 1 3 3 • Space cable supports randomly

Conduit**
1 11 8 4 4 5 between 3 and 4 feet apart to
1 1/4 19 14 6 8 9
prevent system degradation due
1 1/2 25 19 9 11 12
to sagging
*25% fill ratio
**EMT Trade Size. Calculations based on industry standards of 53% capacity for
• Do not use ceiling support wires or
1 cable, 31% for 2 cables, and 40% for 3 or more cables. other ceiling components to support
11
Note: 6A1 = 1st generation, 6A2 = 2nd generation, 6As = Shielded communications infrastructure
CH. 2 Cable Tray Sizing Consolidation Points & Zone Enclosures

HORIZ. To determine the proper tray size based on 25% fill, use the TIA standards allow an optional consolidation point (CP) within
CABLING following calculation: a permanent link. A CAT 6A 110 block is Leviton’s standard
Step Instructions Example CP solution; density is 1/3 less than CAT 6 110 blocks (64-pair
.30" diameter each,
CAT 6A capacity vs. 96-pair for CAT 6 in the same footprint).
1 Determine cable diameter and total number of cables
PATHWAYS & SPACES

100 cables total


Consolidation points may be mounted into a Leviton zone
2 Square the cable diameter .30 x .30 = .09 enclosure, which are available in several styles:

leviton.com/cat6a | 800.722.2082
3 Multiply result by number of cables .09 x 100 = 9
• Ceiling- or floor-mount
Multiply result by .785 to factor for cable roundness • Plenum-rated
4 9 x .785 = 7.065 sq in
(This result is the total cross-sectional area of your cables)
• Active or passive equipment rated
5 Multiply result by 4 to obtain pathway size at 25% fill 7.065 x 4 = 28.26 sq in
Zone enclosures also accept patch panels and/or active
At 25% fill, a 28 sq in area is needed, so a standard 4" x 8" tray would be adequate.
equipment, and are then considered telecom enclosures (TEs).
Note: For conduit, size for 40% fill by substituting 2.5 as the multiplier in Step 5
TELECOM ROOM
Firestopping HORIZONTAL UTP CABLE
TECH TIP

CAT 6A cables may require larger firewall penetrations. Always follow


applicable national code (e.g. NEC or CEC) or a superceding authority- CONSOLIDATION POINT 12
having jurisdiction (AHJ) codes for firestopping requirements. PERMANENT LINK (90m)

CHANNEL (100m)
3. TELECOMMUNICATIONS ROOM

Organizing cable runs at racks and cabinets is essential


to a well-managed network. Larger, heavier CAT 6A
cables may require special planning and equipment for a
successful installation. Select the best patch panels, cable
management, and patch cords or trunks for your application
to speed installation and simplify ongoing management.
CH. 3 110-Style Shielded VertiGO® Zero-U
TELECOM • 1RU 24-port flat and angled • 1RU 24-port flat and angled QuickPort • 12-port panel only, 3" rear
ROOM
• 2RU 48-port flat and angled • 2RU 48-port flat and angled QuickPort channel, or 6" rear channel
Flat 110-style panels are our most popular Shielded panels are ideal for installations where data Patented VertiGO Zero-U panels can be
models; they can be used in a wide variety of security and signal isolation are critical, including mounted on racks or cabinets, to a ladder
applications and offer a standard IDC field with government agencies, banking, gaming, and hospitals. tray or wire basket, directly to the wall, under
easy punchdown. a raised floor, or even onto modular furniture.

leviton.com/cat6a | 800.722.2082
PATCH PANELS

QuickPort® C1 Ultra™ QuickPort


C1 Ultra™ Composite Patch Panel

SPOTLIGHT
Flat, angled, recessed angled, and • 2RU 48-port flat composite
recessed flat: For the ultimate in panel design and customization
Our newest panel offers a high-end aesthetic,
capabilities, choose Leviton’s new C1 Ultra.
• 1RU 24-port superior strength, and customization
capabilities perfect for data centers and Polymer construction has a higher strength-to-
• 2RU 48-port other showroom-style applications. weight ratio than 16-gauge metal and a look
• 2RU 72-port high-density totally unique in the industry. Custom labeling
Flat and angled: options include A/B switch fabric color-coding,
• 1RU 48-port high-density corporate or school logos, or virtually any front
panel design. 14
Our QuickPort panels allow you to color-code your
CAT 6A installations, mix-and match media, and to
add connectors as more capacity is needed.
CH. 3 Vertical Management
TELECOM
ROOM 8" High-Capacity Versi-Duct® 5" Versi-Duct®
• 80" length, standard hinged black cover, front only • 80" length, standard snap-on black cover, front only
• 80" length, standard hinged black cover, front and rear • 80" length, standard snap-on black cover, front and rear
CABLE MANAGEMENT

• 80" length, designer hinged grey cover, front only • 40" length, standard snap-on black cover, front only
• 80" length, designer hinged grey cover, front and rear • 40" length, standard snap-on black cover, front and rear
• Center mounting bracket, 8" channel • Grey snap-on designer cover, front and rear
• Cable retainer and slack loop organizer, 8" channel • Mounting bracket, 5" channel
High-capacity Versi-Duct is ideal for CAT 6A installations, especially large Choose 5" Versi-Duct for smaller installations where its capacity meets
deployments. Choose a designer cover for a sleek look in showroom environments. installation needs, including future growth (see capacity chart below).

Versi-Duct Capacity (# of cables)


CAT 6A Gen1 CAT 6A Gen2 CAT 6A Shielded
Average OD .330" .300" .290"
Fill Rate 25% 50% 25% 50% 25% 50%
5" Channel Size 45 90 55 110 59 118
8" Channel Size 145 290 177 354 190 380
15
CH. 3 Horizontal Management
TELECOM
ROOM Versi-Duct® Rear Cable Management Support Bars Standard Front Cable Management
• Front only • Standard flat, angled, and recessed angled • 1, 2, and 4RU managers with metal rings
• Front and rear • Extended flat • 1 and 2RU managers with plastic saddles
CABLE MANAGEMENT

• 1 and 2RU grey designer covers • High-density flat • SpaceMaker manager


• Bend radius limiters • Rear manager for active equipment flat Standard front managers complement Leviton panel styles

leviton.com/cat6a | 800.722.2082
and keep patch cords visible for easy identification.
Choose horizontal Versi-Duct as part of a complete Rear support bars complement specific panel styles
Versi-Duct cable management solution, or in installations and are included with all Leviton flat panels.
where aesthetics or large finger spacing are priorities.

Leviton VELCRO® Brand Fasteners

SPOTLIGHT
• 5", 8", and 12" tie wraps in four colors plus plenum-rated maroon Need cable management for use
• 15' and 75' bulk rolls in four colors plus plenum-rated maroon in air handling spaces? Leviton’s
large selection of genuine VELCRO®
• 600' bulk rolls Brand fasteners includes several
• 15" compression straps in four colors styles in plenum-rated maroon.
16
• 75' SoftCinch Lite 1/2" wide rolls
• Utility fasteners including saddle ties, J hooks, workstation loops, and storage rings
CH. 3 Leviton Pre-Terminated Copper Trunks
TELECOM Copper trunks are part of Leviton’s extensive, quick turnaround make-to-order
ROOM Leviton SlimLine Patch Cords
(MTO) program. The custom-configured cable assemblies speed installation

SPOTLIGHT
at data centers and other large, critical applications. By shifting much of the Leviton CAT 6A patch cords feature our exclusive
assembly work to the factory, field installation time is reduced by up to 80%. SlimLine plug design. The narrow profile plugs reduce
congestion in high-density applications. In addition,
CABLE ASSEMBLIES

All Leviton trunks include a braided sleeve with pulling eye to protect
they feature a strain relief boot for long-term network
terminations during shipment, ensure easy installation, and keep trunk performance, and a snagless design to prevent tab
assembly organized. In addition, our pre-terminated trunks are 100% factory breakage. An industry-leading outside diameter of
tested and shipped with test results and individual cable serial numbers. .240" further reduces congestion while 26-gauge
No further testing is necessary after installation, and qualified installations stranded cable provides maximum flex-life.
are eligible for our limited lifetime product and performance warranty.
Cable construction provides excellent alien crosstalk
Custom-configuration options: (AXT) suppression and EMI/RFI protection. In fact,
the same cord is deployed for UTP and shielded
• Cable type applications. SlimLine patch cords are component-
• Breakout and overall length (10-295 feet/90 meters) rated for optimum channel performance. The cords are
• Jack, plug, or open termination available in 6 standard lengths from 3 to 20 feet, and
• Even or staggered connector alignment in 8 popular colors.
• Cable and jack color
• Plenum or riser sleeve 17
CH. 3 Cable & Cord Dressing Bend Radius
TELECOM Rear of Rack (cables) To maintain CAT 6A performance, minimum bend radius
ROOM
Whether routing cables from above or below, symmetrically distribute should exceed 4x OD for both UTP and shielded. For CAT
bundles to feed into each panel from left and right. This will balance 6A cables, this radius is significantly larger than CAT 6
the cable bundles, allow easier access to connections, and reduce and 5e. Plan carefully to ensure there is sufficient space
congestion at the rear of the panels. Leviton rear cable managers, to maintain proper bend radius.
Managing CORDS

Versi-Duct® vertical and horizontal finger duct (front/rear versions), and

leviton.com/cat6a | 800.722.2082
Note: In 568-B.2-10, CAT 6A shielded cable bend radius was 8x OD.
VELCRO® Brand fasteners all support CAT 6A cable at the rear of racks
and cabinets.
Color Coding

TECH TIP
Front of Rack (cords) Enhance data center and telecom room organization by
Symmetrically dress cords and route into cable management. Leviton’s color-coding connectors and patch cords. Choose from
CAT 6A cords have been independently and field-tested to ensure 10G several schemes, depending on application and system
management priorities:
performance whether they are strictly combed or randomized in cable
managers. Our horizontal ring-type cable managers as well as horizontal • A/B switch fabric for data center redundancy
and vertical Versi-Duct products help manage patch cords at the front • Connectivity types such as WAN/corporate data, LAN,
of the rack. To reduce cord bundle sizes, consider using angled patch engineering networks, voice, and more
panels with vertical Versi-Duct. Also consider Leviton SlimLine CAT 6A • Campus location
18
patch cords; their low-profile will reduce congestion at the face of the • Company colors
patch panel and on high-density switch equipment.
4. WORK AREA

Connectivity in the work area requires a finished look,


ease of maintenance, and performance, all while meeting
installation codes and guidelines. Simplify work area
connectivity planning, design, and installation with the
following tips.
CH. 4 In-Wall Applications
Leviton Consolidation Points & Zone Enclosures
CAT 6A cables require additional depth

SPOTLIGHT
WORK
AREA behind faceplates and at all directional Reduce the cost and complexity of moves, adds,
and changes with Leviton’s consolidation point
changes to maintain proper bend 110-Style Wiring Block
(CP) solutions. Our TIA-compliant solutions allow
radius. Before installation, verify that
businesses to add an interconnection point within a
WORK AREA CABLING

the design allows sufficient depth


horizontal cabling permanent link. When work areas
throughout the run. are modified, cabling need only be reconfigured

leviton.com/cat6a | 800.722.2082
back to the consolidation point, rather than all the
way to the telecom room.
Drop Ceiling Applications
Leviton’s standard CAT 6A consolidation point
Cable infrastructure must be independently solution is our 110-style wiring block. Mount into a
suspended by components designed Leviton zone enclosure, available in several styles:
for this purpose, separate from all other Active Ceiling Enclosure
• Ceiling- and floor-mount
building systems. Do not use ductwork,
• Plenum-rated
piping, earthquake bracing, or the drop
• Active or passive equipment rated
ceiling grid to suspend cable or cabling
support infrastructure. Zone enclosures also accept patch panels and/or
active equipment, and are then considered telecom 20
enclosures (TEs).
Passive Raised-Floor Enclosure
CH. 4 Junction Boxes and Mud Rings Surface Mount Boxes
WORK Verify that the connectivity design specifies the To maintain proper bend radius, consider exiting
AREA proper junction box size before drywall is installed. cable from modular furniture pathways into
Consider an oversized junction box to accommodate a surface mount box instead of directly to a
CAT 6A cabling and bend radius requirements, or use faceplate. Leviton’s extended depth four-port
mud rings (box eliminators) instead. surface mount box works with most modular
furniture and is an excellent solution for larger
WORKSTATION

CAT 6A bend radius requirements.

Modular Furniture Installations

TECH TIP
Cubicle furniture and walls often have restricted
wireways. Determine cable capacity before finalizing
specifications to verify there is adequate space for
cables and bend radius requirements. Consider mocking
up a cubicle. Most cubicle installations use surface
mount boxes or modular furniture faceplates, which help
offset the space restrictions of narrow cubicle walls.
21
CH. 4

WORK SPOTLIGHT Leviton QuickPort® Faceplates & Inserts


AREA
Leviton offers numerous QuickPort opening faceplates to match any décor. Choose from:

• Standard commercial, Decora® or Acenti® designer, or Excella™ British Standard styles


• Stainless steel construction or thermoplastic in seven popular colors
• Single- or dual-gang with 1- to 12-port capacity
• Openings for data connectors or multimedia connectivity

leviton.com/cat6a | 800.722.2082
WORKSTATION

• With or without ID windows

22
Standard Commercial Acenti Decora Angled Excella
5. DATA CENTER APPLICATIONS

Data centers are one of the most critical parts of any data network
and thus require the highest levels of performance and reliability.
Cabling for data centers differs from horizontal installations in
several ways: typical distances, network function, pathways and
spaces, and more. CAT 6A cabling may affect requirements for all
of these, but especially pathways and spaces. Careful planning and
proper specifications will help ensure a successful installation.
CH. 5 Raised Floor vs. Overhead Cable Runs
DATA There are three typical data center CAT 6A cable run Follow best-practice CAT 6A installation guidelines to achieve and
CENTER configurations: power and data cabling both under a raised floor, maintain optimum performance:
both overhead, or power below and data overhead. The chosen
• Pathways should be sized for 25% initial fill ratio, which allows space
configuration will affect other data center design elements:
for up to 50% fill with future additions. Pathways should be no more
PATHWAYS & SPACES

• If power and communications cable are both overhead, than 6" deep; larger deployments may use multiple trays or pathways
cable trays must be properly sized, separated, and to support cabling requirements.

leviton.com/cat6a | 800.722.2082
configured to support 6A cables and accommodate • Space cable bundle supports every three to four feet at irregular intervals.
power runs.
• Leviton trunks can be pre-terminated or field terminated. There are
• If both are underfloor, pedestals must be higher to numerous advantages to using pre-terminated trunks, including factory
accommodate larger 6A cables, room for expansion, testing for alien crosstalk (AXT); see page 17 for a detailed discussion.
segregation from power runs, and proper airflow.

Leviton Component-Rated Performance


SPOTLIGHT

Leviton component-rated CAT 6A solutions offer guaranteed performance at permanent link distances as short as 10
feet, which is critical in data center applications. How? With patent-pending triple-stage compensation. An advanced rigid
circuit board design, engineered tine geometry, and a flexible circuit combine to enhance permanent link and channel 24
performance, and minimize the adverse effects of near end crosstalk (NEXT), return loss (RL), and alien crosstalk (AXT).
CH. 5 Pre-Terminated Copper Trunks Leviton C1 Ultra™ Composite Patch Panel
DATA Reduce installation time by up to 80% The new Leviton C1 Ultra combines strength and durability with
CENTER with Leviton make-to-order (MTO) a sleek look ideal for data centers. Polymer construction has a
copper trunks. All MTO trunks are higher strength-to-weight ratio than 16-gauge metal and a look
NEW CAT 6A SOLUTIONS

100% factory tested and shipped totally unique in the industry. Custom labeling options include A/B switch
with test results and individual cable fabric color-coding, corporate or school logos, or virtually any front panel
serial numbers. No further testing design. The 2RU 48-port flat QuickPort® panel accepts eXtreme® CAT 6A
is necessary after installation, and component- or channel-rated connectors.
qualified installations are eligible
for our limited lifetime product and 8" x 8" Versi-Duct® Cable Management
performance warranty. High-Capacity Versi-Duct is ideal for CAT 6A data center
Configuration options: installations. The large channels accommodate larger outside
• Cable type diameter CAT 6A cables, while channel covers help create a
• Breakout and overall length (up to finished look in showroom-style installations. Managers can be
90 meters) side or center mounted for optimal space utilization.
• Jack, plug, or open termination
• 80" length with standard hinged black cover, front only or front and rear
• Even or staggered plug alignment
• 80" length with designer hinged grey cover, front only or front and rear
• Cable and jack color
• Center mounting bracket
• Plenum or riser sleeve 25
• Cable retainer and slack loop organizer
CH. 5
Component-Rated Connectors SlimLine Component-Rated Patch Cords
DATA For unparalleled performance, choose the eXtreme CAT 6A
® Leviton SlimLine patch cords feature a narrow profile plug to reduce
CENTER component-rated connector – the first in the industry to achieve congestion in high-density data center applications. A wealth of
this stringent benchmark. It has the best available performance features maximizes performance:
NEW CAT 6A SOLUTIONS

for short run applications, down to a 10' permanent link. In fact, • Exceptional alien crosstalk suppression and EMI/RFI protection
it's so well designed, it even meets component requirements • The same cord is used for both UTP and shielded applications
when loaded in a 1RU 48-port QuickPort® panel. • Strain relief boot ensures long-term network performance

leviton.com/cat6a | 800.722.2082
Leviton-exclusive features combine to deliver a connector with • Snagless design prevents tabs breakage during moves, adds, and changes
best-in-class performance and functionality: • 26-gauge stranded cable and .24" OD provide maximum flexibility

• Patented dual-layer T568A/B label with larger wiring diagrams


• Patented Cone of Silence® and metalized body help suppress Leviton Data Center Specialists

SPOTLIGHT
alien crosstalk (AXT)
Need help with a CAT 6A data center infrastructure project? Our DC
• Patented Retention Force Technology protects against
specialists provide technical support including design, layout, elevations,
damage from four- or six-pin plugs
pathways, and specifications to support any data center architecture
• Patent-pending triple-stage compensation enhances margin and equipment requirements. Team members average more than two
performance and augments AXT suppression
decades of industry experience and have a deep understanding of
• Sharper Pair Separation Towers ease conductor separation industry best practices and our customers needs. 26
• Conductor retention feature holds wires during termination
Email dcteam@leviton.com for more information.
6. CAT 6A TERMINATION

Termination steps for CAT 6A connectors are much the same as for CAT 6,
with the major exception of handling the cable’s larger OD. To compensate,
Leviton has designed several exclusive features into its new CAT 6A connectors
to speed termination. Read on for details of these features, other tips for
a seamless installation, and for termination instructions for our 110-style
panel, UTP connectors, and shielded connector.
CH. 6 Extra Cable for Re-terminations Leviton CAT 6A Connectors

SPOTLIGHT
TERMI- TIA recommends storing 10 feet of extra cable in All eXtreme® CAT 6A UTP connectors include several
NATION the telecom room and 12-18 inches above work area features that deliver ease-of-use and superior performance:
installations for re-terminations and to accommodate • Patented dual-layer T568A/B label with larger wiring diagrams
moves, adds, and changes. Use an extended or figure
• Patented Cone of Silence® and metalized body to help
8 loop configuration to alleviate cable stress. Cable
suppress alien crosstalk (AXT)
TERMINATION TIPS

slack in bundled or excessive loops has been shown

leviton.com/cat6a | 800.722.2082
• Patented Retention Force Technology protects against
to degrade cable performance and is associated with
Component-Rated CAT 6A
damage from four- or six-pin plugs
return loss failures.
Our component-rated UTP connectors add performance-
enhancing features:

Leviton Palm Termination Tool • Patent-pending triple-stage compensation enhances


SPOTLIGHT

margin performance and augments AXT suppression


Use Leviton’s Palm Termination Tool to quickly and
easily punch down connectors at the jobsite. The Palm Channel-Rated CAT 6A • Sharper Pair Separation Towers ease conductor separation
Tool offers an ergonomic comfort grip, increased • Conductor retention feature holds wires during termination
connector stability, and integrated holes that allow
CAT 6A shielded connectors offer superior signal isolation
rack mounting for QuickPort® panel terminations.
and EMI/RFI protection, a 270° hinge for easy access,
The Palm Tool is compatible with all CAT 6A/6/5e and 28
no punchdown tool needed, and snap-close cap when
standard QuickPort A/V connectors.
termination is complete.
Shielded CAT 6A
CH. 6
eXtreme® CAT 6A 110-Style Patch Panel Termination
TERMI-
NATION 1 Mount the eXtreme CAT 6A 110-Style Patch Panel to 5 Starting with the middle two pairs (orange/white and green/
a standard 19" equipment rack or wall-mount bracket, white) use your fingers to carefully seat and secure the wires into
using the provided screws. the IDC slots. Maintain wire pair twisting to within 1/2" of the IDC
contact. Then position a 110-style impact tool (set to low impact)
2 Determine which color-coded wiring scheme is desired
perpendicular to the IDC slot, seat and trim the cable.
(T568A or T568B).
INSTRUCTIONS

NOTE: If wires appear to be “bridged” over the IDC, rather than securely
NOTE: The color codes and port numbers are located on
seated into the slot, pull out the wires and reseat and repunch them
the panel labels between termination (IDC) slots.
(Figure B).
3 Remove approximately 3" of the jacket and center
spline/separator from cable. 6 Once the CAT 6A module has been terminated, snap the 3-port
retention cap to the back of the connector top and bottom sides.
4 Route jacketed wire to the termination field so that the The retention cap can also be broken into single pieces (Figure C).
jacket is centered near the IDCs (Figure A).
After the panel has been fully terminated, attach the cable
CAUTION: Use of mass termination impact tool is not management bar to the back of patch panel (Figure D).
permissible for this product.
29
CH. 6

TERMI-
NATION

A. B. C. D.
"Bridged" Wire Retention Dust Cap

leviton.com/cat6a | 800.722.2082
Cable
INSTRUCTIONS

Management
Bar

30
CH. 6
eXtreme® CAT 6A Component- and Channel-Rated Connector Termination
TERMI-
NATION 1 Remove about 3" of cable jacket and center spline (stiff plastic separator
inside CAT 6A cable).

2 Determine whether to use wiring scheme T568A or T568B. Note the


T568A & T568B WIRING STANDARDS IDC
associated color codes and connector pin number on the label located COLOR ASSIGNMENTS
between the IDC connector slots (Figure A). Peel back label for T568A wiring.
INSTRUCTIONS

CONNECTOR T568A T568B


3 Leave the cable jacket within 1/8" of the connector side, then route the wires Pin # Wire Colors Wire Colors
for termination using the selected wiring scheme (Figure B). Route cable
1 White/Green White/Orange
perpendicular to the IDC field. Ensure there is enough slack in the twisted
pairs, and do not place the cable jacket into the termination field. 2 Green Orange
3 White/Orange White/Green
4 Use your fingers to carefully seat wires into the IDC slots. Maintain wire pair
4 Blue Blue
twisting to within 1/2" of the IDC. Set a 110-style impact tool to low and
position it perpendicular to the connector. Seat and trim the cable one pair at 5 White/Blue White/Blue

a time to prevent crushing the inside pairs (Figure C). 6 Orange Green
7 White/Brown White/Brown
5 Place the Cone of Silence® over the terminated wires for secure connection
and guaranteed CAT 6A performance (Figure D). 8 Brown Brown 31
CH. 6

TERMI-
NATION

A. B. C. D.

leviton.com/cat6a | 800.722.2082
INSTRUCTIONS

eme
®

eme eXtrT 6A
®

eXtrT 6A CA eme
®

CA eXtrT 6A
CA

32
CH. 6
CAT 6A Shielded Connector Termination
TERMI-
NATION 1 Strip a minimum of 1.5" of jacket from the end of the 5 Make sure that arrows on both connector and cap point in
cable. For F/UTP cable, pull the foil or braided shield back the same direction, align the cap with the IDC towers, and
over the jacket, and wrap the drain wire around the shield. press into position. Rotate the cap wings toward each other
For U/FTP cable, fold the foil from each twisted pair over until they snap closed (Figure D).
the jacket and wrap the drain wire around the shield.
6 Ensure that the drain wire is wrapped around the cable and
INSTRUCTIONS

2 Insert the wires from the stripped cable into the stuffer shield. Tie-wrap the drain wire to the shield. Do not over-
cap through the hole (Figure A). tighten the tie wrap! It should be snug, but not so tight that
it crushes the wires (Figure E).
3 Determine whether to use wiring scheme T568A or
T568B. Insert the wires into their correct positions per
the desired wiring scheme (Figure B).

4 Using a flush cutter, cut the excess wire off as close


to the edge of the cap as possible (Figure C). Wire tips
should not protrude more than 1/32 of an inch.

33
CH. 6
INSTRUCTIONS

TERMI-
NATION

D.
A.

A
B
A
B

E.
B.

B
C.

leviton.com/cat6a | 800.722.2082
34
7. CAT 6A TESTING

Field testing of CAT 6A installations is much like field testing for CAT 5e and
CAT 6. However, CAT 6A testing is performed out to the higher frequency of
500 MHz. In addition, CAT 6A adds several tests for alien crosstalk (AXT).
CH. 7 CAT 6A Performance Tests Field Testing
CAT 6A • Wire map • Return loss (RL) Use an industry-recognized
TESTING
• Length • PSFEXT – power sum far-end crosstalk UL Level 4 field tester
capable of testing to 500
• Attenuation • PSACRF – power sum attenuation-to-crosstalk
MHz. Contact the test
PERFORMANCE TESTS

• Propagation delay ratio, far-end


equipment manufacturer for
• Delay skew • AACRF – alien attenuation-to-crosstalk ratio, any necessary hardware or

leviton.com/cat6a | 800.722.2082
far-end software upgrades, including
• NEXT – near-end crosstalk
• AFEXT – alien far-end crosstalk AXT testing capabilities, for
• PSNEXT – power sum near-end crosstalk testing CAT 6A installations.
• ANEXT – alien near-end crosstalk
• FEXT – far-end crosstalk Perform permanent link or
• PSAACRF – power sum alien attenuation-to- channel tests for all installed
• ELFEXT (ACRF) – equal level far-end
crosstalk ratio, far-end drops. Upon completion,
crosstalk (attenuation-to-crosstalk ratio,
• PSAFEXT – power sum alien far-end crosstalk provide the customer with all
far-end)
test results.
• PSELFEXT (PSACRF) – power sum equal • PSANEXT – power sum alien near-end crosstalk
level far-end crosstalk (power sum
attenuation-to-crosstalk ratio, far-end) 36
CH. 7

PSANEXT PSAACRF
CAT 6A Leviton AXT Performance

SPOTLIGHT
TESTING
Alien crosstalk (AXT) can have a
serious impact on CAT 6A cabling
system performance. Choose
Leviton and get guaranteed
AXT suppression. Independent
3rd-party and Leviton tests have
proven that properly installed
AXT TESTING

Leviton CAT 6A solutions have


significant AXT headroom over
the standard’s requirements,
even for permanent links as short
as 10 feet. As a result, properly
installed Leviton systems with
approved cable do not require
field alien crosstalk testing. In
addition, Leviton pre-terminated,
Frequency (MHz): (Blue - Worst Case, Green - Average) Frequency (MHz): (Blue - Worst Case, Green - Average)
pre-tested trunk cables do not
require any field testing.
Independent (ETL) Test Results for Leviton Short Channel (30 ft.) CAT 6A System
37
CH. 7 AXT Testing Preparation
Is AXT Testing Required?
TECH TIP
CAT 6A AXT testing measures the unwanted noise coupled to the cable being tested
Even though Leviton does not
TESTING
require field AXT testing for its (called the “Victim” or “Disturbed”) by six surrounding cables (called “Disturbers”).
CAT 6A solutions, you may still be Two tests need to be performed: The Power Sum Alien Near-end Crosstalk
required to perform this testing. (PSANEXT) test and the Power Sum Alien Attenuation-to-Crosstalk Ratio, Far-end
Read project specifications (PSAACRF) test. Results for the remaining AXT tests are taken as part of these
carefully to determine if they two, so although they are not directly provided, a “pass” result for PSANEXT and

leviton.com/cat6a | 800.722.2082
call for field AXT testing. If
PSAACRF ensures passing results for AACRF, AFEXT, ANEXT, and PSAFEXT. A 2%
AXT TESTING

they do, ask for a waiver based


on the proven performance of sample of the installed cables is typically recommended; testing the longest cables
Leviton’s CAT 6A solutions. If the in the installation will provide the most meaningful results.
customer won’t grant a waiver,
you’ll need to perform the testing. AXT testing requires special planning, equipment and training:
Read the following “AXT Testing
• AXT tests are time-consuming! Budget AXT test time into your bid
Preparation” section to gain a
better understanding of field AXT • Handheld test instruments (field testers) require an adjunct AXT module
testing requirements. • A laptop computer is also typically used with the field tester
• The field tester’s AXT application software must be loaded onto the laptop
• Installation personnel will require training prior to performing AXT testing
38
8. PART NUMBERS
CH. 8
110-STYLE EXTREME® 6A Component-Rated Patch Panels QUICKPORT® PATCH PANELS

PART DESCRIPTION PART NO. DESCRIPTION PART NO.


NUMBERS
Flat, 1RU, 24-port 6A586-U24 1RU, 24-port, black connectors included 6910G-U24
Flat, 2RU, 48-port 6A586-U48 1RU, 24-port, empty 49255-H24
Angled, 1RU, 24-port 6A587-U24 1RU, 48-port, black connectors included 6910G-D48

FLAT
UTP PATCH PANELS

Angled, 2RU, 48-port 6A587-U48 2RU, 48-port, black connectors included 6910G-U48

leviton.com/cat6a | 800.722.2082
C1 ULTRA™ COMPOSITE Patch Panels 2RU, 48-port, empty 49255-H48
2RU, 72-port, empty 49255-D72
QuickPort, flat, 2RU, 48-port, empty C1255-H48
1RU, 24-port, empty 49256-H24
VertiGO® Zero-U Patch Panels
1RU, 48-port, empty

ANGLED
12-port, panel only, empty 49280-QP0 49256-D48
(for use with 6A10G CAT 6A connectors)
12-port with 3" channel, empty 49280-QP3 2RU, 48-port, empty 49256-H48

12-port with 6" channel, empty 49280-QP6 2RU, 72-port, empty 49256-D72
1RU, 24-port, empty 4W256-H24

RECESSED
ANGLED
2RU, 48-port, empty 4W256-H48
40
2RU, 72-port, empty 4W256-D72
CH. 8 UTP Shielded
PART CONNECTORS CONNECTORS
NUMBERS
DESCRIPTION PART NO. DESCRIPTION PART NO.
eXtreme 6A component-rated
®
6A10G-R†6 CAT 6A shielded 6S10G-S6A
eXtreme 6A channel-rated 6110G-R†6 PATCH CORDS
PATCH CORDS eXtreme CAT 6A component-rated SlimLine 6AS10-xx*
UTP/SHIELDED

eXtreme 6A component-rated SlimLine 6AS10-xx* PATCH PANELS


CROSS CONNECT QuickPort®, flat, 1RU, 24-port, empty 4S255-S24
eXtreme 6A 110-style wiring block kit, with legs and 41D6A-1F4 QuickPort, flat, 2RU, 48-port, empty 4S255-S48
C-4 clips, 64-pair
QuickPort, angled, 1RU, 24-port, empty 4S256-S24
† = Connector colors: Choose from any of the colors below.
QuickPort, angled, 2RU, 48-port, empty 4S256-S48
xx = Length: (03), (05), (07), (10), (15), or (20) feet.
Custom length cords available, call inside sales at 800.722.2082 or +1.425.486.2222
for more information.
White (W) Light Almond (T) Almond (A) Ivory (I) Yellow (Y) Orange (O) Crimson (C) * = Patch Cord colors: Choose from any of the colors below.

Dark Red (R) Purple (P) Blue (L) Green (V) Grey (G) Black (E) Brown (B) White (W) Yellow (Y) Orange (O) Red (R) Blue (L) Green (G) Grey (S) Black (E) 41
CH. 8
VERSI-DUCT® CABLE MANAGERS VELCRO® Brand Fasteners

PART
DESCRIPTION FRONT ONLY FRONT & REAR DESCRIPTION BLACK COLORS
NUMBERS
80" length, standard cover 8980L-VFO 8980L-VFR 5" tie wrap 43105-005 43105-05*
8" X 8" CHANNEL

80" length, designer cover 8C80L-VFO 8C80L-VFR 8" tie wrap 43108-008 43108-08*
Center-mount bracket – 89265-BKT 12" tie wrap 43112-012 43112-12*
CABLE MANAGEMENT

Slack loop organizer – 89265-SL1 15' bulk roll 43115-015 43115-15*

leviton.com/cat6a | 800.722.2082
Cable retainer – 89265-wr1 75' bulk roll 43115-075 43115-75*
80" length, standard cover 4980L-VFO 4980L-VFR 600' bulk roll 43115-600 –
Channel

44115-15*
5" x 4"

40" length, standard cover 4940L-VFO 4940L-VFR 15" compression strap 44115-15E
(no maroon)
Center-mount bracket – 49265-BKT 75' SoftCinch Lite roll 4S115-75E –
Designer cover, grey – 59265-5DC * = Colors: Choose from any of the colors below. Maroon fasteners are plenum-rated.
2RU, black cover 492RU-HFO 492RU-HFR
Horizontal

1RU, black cover 491RU-HFO 491RU-HFR


Blue (L) Yellow (Y) Orange (O) Maroon (P)
2RU designer cover, grey – 49265-DC2
See Leviton’s full product catalog for more VELCRO® Brand utility fastener part numbers.
1RU designer cover, grey – 49265-DC1 42
Leviton offers a wide variety of metal front and rear cable managers. Go online to Leviton.com
Cable retainer – 49265-WR1 or see our full product catalog for the complete selection.
9. GLOSSARY
10GBASE-T (10 Gigabit baseband over twisted AXT (alien crosstalk) is electromagnetic noise that Category 5e (enhanced category 5 or CAT 5e)
pair) This IEEE standard, 802.3an, defines 10 Gigabit can occur in a cable run alongside other signal- is a standard for balanced twisted pair cable and
Ethernet running 10Gbps over balanced twisted- carrying cables. The term “alien” arises from the fact components supporting signaling rates up to
pair cabling. that this form of crosstalk occurs between different 100 MHz. CAT 5e is intended to support systems up
cables in a group or bundle, rather than between to 1000BASE-T or Gigabit Ethernet up to distances
ANSI (American National Standards Institute) individual wires or circuits within a single cable. of 100 m (328 ft).
ANSI oversees the creation, circulation and use
of standards and guidelines that directly impact Bandwidth The difference between the highest and Category 6 (CAT 6) is a standard for balanced

leviton.com/cat6a | 800.722.2082
businesses in various sectors. ANSI is also actively the lowest frequencies of a transmission channel twisted pair cable and components supporting
engaged in accrediting programs that assess (path for information transmission). Identifies the signaling rates up to 250 MHz. CAT 6 is intended
conformance to standards. amount of data that can be sent through a given to support systems up to 1000BASE-T or Gigabit
channel. Measured in hertz (Hz); higher bandwidth Ethernet up to distances of 100 m (328 ft).
Attenuation The loss of volume during numbers mean higher data capacity.
transmission, or decrease in the power of a signal, Category 6A (augmented category 6 or CAT 6A)
light beam, or light wave. Attenuation is the opposite Bend Radius The amount of bend that can is a standard for balanced twisted pair cable and
of gain and is measured in decibels (dB). occur before a cable may sustain damage or components supporting signaling rates up to 500
increased attenuation. MHz. CAT 6A is designed to support 10GBASE-T or
AWG (American wire gauge) is the standard 10 Gigabit Ethernet up to distances of 100 m (328 ft).
measuring gauge for nonferrous conductors (i.e., BICSI (Building Industry Consulting
non-iron and non-steel). Gauge measures the Services International) is a non-profit Category of Performance Cabling and 44
diameter of a conductor (thickness of cable). professional association for the promotion of cabling component standards adopted by the
telecommunications industry standards. telecommunications industry.
Channel In the horizontal cabling portion of a specifications are more stringent than channel jacks are connectors, not all connectors are jacks.
structured cabling system, the channel contains specifications and may provide greater permanent
all of the elements of the permanent link, plus the link and channel test margins. Compare with Consolidation Point An optional location between
equipment cords at the horizontal cross-connect Channel-rated. an ER or TR and the workstation for interconnection
(HC) and the patch cords in the work area. of horizontal cables.
Conductor Any substance, usually a wire or cable,
Channel-rated Category-rated structured cabling that can carry an electrical current. Data Center (DC) A data center is a facility used
components are said to be channel-rated if, when for housing a large amount of electronic equipment,
installed as a system in an industry-defined Connecting Block Also called a terminal block, typically servers, computers, data storage devices,
channel, they meet all of the transmission and noise punch-down block, quick-connect block, or cross- and communications equipment. Data centers are
characteristics defined in the standard. Compare connect block, this plastic block contains metal designed to assure that the equipment and data
with Component-rated. wiring terminals to establish connections from one housed in them are protected from environmental
group of wires to another. Usually each wire can be hazards and security breaches. Data centers can be
Compliance A wiring device that meets all connected to several other wires in a bus or common private, serving a single company, or a public “utility”
characteristics of a standard is said to be in arrangement. There are several types of connecting serving a variety of companies.
compliance with that standard. blocks: 66, 110, etc.
dB (decibel) A dB is a unit of measure of signal
Component-rated Category-rated structured Connector A device that connects wires or fibers strength, usually the relationship between a
cabling components are said to be component- in cable to equipment or other wires or fibers. Wire transmitted signal and a standard signal source. Every
rated if they exceed all of the transmission and and optical connectors most often join transmission 3dB equals 50% of signal strength, so therefore a 6dB
noise characteristics defined in the standard for an media to equipment or cross connects. Connectors loss is a loss of 75% of total signal strength.
individual structured cabling component. Component are sometimes referred to as jacks; but although all 45
EIA (Electronic Industries Alliance) The EIA is a trade equipment, cross-connect equipment, and building Gigabit When used to describe data transfer
organization made up of manufacturers that set systems (e.g. life safety, security, electrical and HVAC). rates, Gigabit refers to 10 to the 9th power
standards for its member companies. (1,000,000,000) bits. Gigabit Ethernet, abbreviated
FCC (Federal Communications Commission) The FCC GbE, supports data transfer rates of 1 Gigabit (1,000
Ethernet Leading local area network (LAN) protocol is an independent United States government agency. megabits) per second. The first Gigabit Ethernet
used for connecting computers, printers, workstations, It was established by the Communications Act of standard (802.3z) was ratified by the IEEE 802.3
terminals, etc. within the same building. Ethernet is a 1934 and is charged with regulating interstate and Committee in 1998.
physical link and data link protocol that operates over international communications by radio, television, wire,

leviton.com/cat6a | 800.722.2082
twisted pair wire. See IEEE 802.3x. satellite and cable. The FCC's jurisdiction covers the 50 HC (horizontal cross-connect) The HC is a location
states, the District of Columbia, and U.S. possessions. for the cross-connect of horizontal cabling to other
ETL (Edison Testing Laboratories) is an independent cabling and equipment.
testing, inspection and certification laboratory FTP (foiled twisted pair) is balanced twisted pair
owned by Intertek that provides electrical safety, cable with an overall foil shield and drain wire. Also IC (intermediate cross-connect) The IC is a cross-
electromagnetic compatibility, benchmark and called screened twisted pair (ScTP) cable. connect point located between the MC (main cross-
performance testing. In addition, ETL issues two connect) and the HC in interbuilding backbone cabling.
product safety marks: “listed” and “verified”. F/UTP (foiled screened with unshielded twisted
pairs). Overall shielded cable with no shield on IDC (insulation displacement connection) An IDC
ER (equipment room) is a centralized space that individual twisted pairs. allows the termination of a conductor without
houses telecommunications equipment. ERs stripping the conductor’s insulation. When the
generally serve an entire building or campus, while Gain An increase in signaling power when an electric conductor is inserted into the contact, the insulation 46
TRs (telecommunication rooms) serve one floor of a device boosts the signal; measured in decibels (dB). is displaced, creating contact between the conductor
building or a portion of a floor. An ER may contain active and the IDC, producing a gas-tight connection.
IEEE (Institute of Electrical and Electronics inserted into the circuit. a single building or contiguous campus. LANs
Engineers) is a publishing and standards-making are characterized by higher data-transfer rates
body responsible for many standards used in LANs. Interconnect A circuit administration point, other (compared to a WAN or wide area network) and lack
than a cross-connect or an information outlet, that of leased telecommunications lines.
IEEE 802.3 is a collection of IEEE standards provides capability for routing and rerouting circuits.
defining the physical layer and the media access It does not use patch cords or jumper wires, and Mbps Megabits Per Second. One million bits
control (MAC) sublayer of the data link layer of typically is a jack-and-plug device used in smaller per second.
wired Ethernet. This is the most common local area distribution arrangements or that connects circuits
network specification. in large cables to those in smaller cables. MC (main cross-connect) The MC is the cross-connect
in the ER (equipment room) for connecting entrance
IEEE 802.3an is a standard for 10GBASE-T ISO (International Standards Organization) is the cables, backbone cables and equipment cables.
released in 2006 to provide 10 gigabit per second world's largest developer and publisher of international
transmission over balanced twisted pair cables up to standards. It is a non-governmental organization MHz (megahertz) is a unit of frequency denoting
100 meters (328 ft). (NGO) network of national standards institutes in 157 one million hertz (1,000,000 cycles per second).
countries, based in Geneva, Switzerland.
Impedance The total opposition (i.e. resistance and Mud Ring Industry jargon for a plaster ring/frame
reactance) a circuit offers to the flow of alternating Jacket (also cable jacket or sheath) The outer mounted in a wall to support a telecommunications
current. It is measured in ohms, and the lower the covering applied over internal cable elements outlet such as a faceplate. Essentially, mud rings are
ohmic value, the better the quality of the conductor. for protection. backless junction boxes.

Insertion Loss (IL) The difference in the amount of LAN (local area network) A LAN is a computer
power received before and after something is network covering a small physical area, generally 47
NEC (National Electric Code) The NEC or NFPA 70 A or B with an 8-position, 8-conductor (8P8C) plug Performance The totality of a communication
(NFPA is the National Fire Protection Association, on each end. Work area and TR patch cords are made transmission’s characteristics, including rate
the organization that publishes the Code) addresses from stranded cable, which has better flexibility, of transfer, barriers to peak transfer rate, and
safeguards for people and property from electrical durability and longer life than solid-conductor cords. comparison to applicable standards. Compare with
hazards. The NEC also specifies fire resistance Compliance. A device can exhibit performance
and smoke ratings for building materials and is Patching A means of connecting circuits via cords characteristics without being compliant to an
recognized and enforced in the United States. and connectors that can be easily disconnected and industry standard.
NEC article 800 addresses requirements for reconnected at another point. May be accomplished

leviton.com/cat6a | 800.722.2082
communications circuits. by using modular cords connected between jack Permanent Link In the horizontal cabling portion
fields or by patch cord assemblies that plug onto of a structured cabling system, the permanent link
NEXT (near-end crosstalk) Electrical noise coupled from connecting blocks. contains the following: the telecommunications
one pair of wires to another within a multi-pair cable. outlet (TO), the cabling between the horizontal
Patch Panel A piece of connecting hardware cross-connect (HC) and the TO, an optional
Part 68 Requirements specifications established designed for use in a standard 19" equipment rack consolidation point (CP), and the connecting
by the FCC as the minimum acceptable protection or cabinet. Standard patch panels have modular hardware at the HC.
communications equipment must provide the jack appearances on the front, and 110-style IDC
telephone network. connections on the rear. Field-configurable patch Power Sum A test method for four-pair cable
panels can be loaded with a variety of jacks or other whereby the mathematical sum of pair-to-pair
Patch Cord A cord made from 4-pair 100-ohm connectors for mixed-media installations, or where crosstalk from three pairs to one pair is measured.
balanced twisted-pair cable. Patch cords may be the use of various jack colors is desired. 48
shielded or unshielded, depending on the type of
system being installed. They are typically wired T568
Premises Telephony term for the space occupied by Return Loss (RL) is a measure of the similarity Structured Cabling System A structured cabling
a customer or authorized/joint user in a building(s) of the impedance of a transmission line and system (SCS) is defined as the complete collective
on continuous or contiguous property (except railroad the impedance at its terminations. It is a ratio, configuration of cabling and associated hardware
rights of way, etc.) not separated by a public road or expressed in decibels, of the power of the outgoing that has been installed at a given site to provide a
highway. Frequently used as “premises-based”. signal to the power of the signal reflected back. comprehensive telecommunications infrastructure.

Premises Wiring System The entire wiring system RJ (registered jack) RJs are telephone and data TDMM (Telecommunications Distribution Methods
on the user’s premises, especially the supporting jacks registered with the FCC. Specific RJs, such Manual). The TDMM is a publication from BICSI that is
wiring that connects the communications outlets to as RJ-11 and RJ-45, are widely misused in the based on internationally accepted industry standards,
the network interface jack. telecommunications industry. A much more codes and guidelines. The TDMM addresses the newest
accurate way to identify a jack is to specify the methodologies and recommends best practices for the
Punchdown Refers to the use of an impact tool number of positions (width of opening) and number design of structured cabling systems.
that enables installers to make efficient IDC of conductors. Example: “8-position, 8-conductor
style connections. (8P8C) jack” or “6-position, 4-conductor (6P4C) jack”. TE (Telecommunications Enclosure) Also referred
to as a zone enclosure, a TE is a housing for
RCDD® (Registered Communications Distribution RU (rack unit) is a unit of measure of vertical space telecommunications equipment, cable terminations,
Designer) The RCDD title is a professional credential in an equipment rack or cabinet. One rack unit is cross-connect cabling, and wireless access points.
granted by BICSI. RCDDs have demonstrated a equal to 1.75 in (45 mm). A TE serves the function of an horizontal cross-
superior level of knowledge of Information Transport connect (HC) for a portion of a building floor and
Systems (ITS) design and associated disciplines. Standards Agreed-upon principles of performance. provides access to the building’s backbone and
Standards are set by committees working under pathways. A TE should supplement, not replace, the
various trade and international organizations. requirement for a TR on a building floor. 49
TIA (Telecommunications Industry Association) UL (Underwriters Laboratories®) is a privately owned
The TIA is a trade organization of manufacturers product safety certification organization.
which sets standards for use of its member UL also certifies category-rated cable performance
companies. Formerly fell under the umbrella of EIA. and quality.
See www.tiaonline.org.
UTP (unshielded twisted pair), also classified
TO (telecommunications outlet) is a connecting as U/UTP, is overall unshielded twisted pair with
device in the work area on which horizontal unshielded twisted pairs.

leviton.com/cat6a | 800.722.2082
cable terminates.
Work Area (WA) or workstation, is a building space
TR (telecommunications room) A TR is where occupants interact with telecommunications
an architectural space that provides an terminal equipment.
environmentally suitable and secure area for
housing cables, terminations, cross-connects, WAN (wide area network) is a computer network
hardware and telecommunications equipment. that covers a broad geographic area. WANs connect
LANs and other networks together. Some are private,
U/FTP also classified as STP (shielded twisted pair), but many are built by Internet service providers, who
is twisted pair cable with individually foil-screened provide connection from organizational LANs to the
twisted pairs, but no overall shield. Internet.
50
This guide has been developed consistent with all known applicable cabling practices as defined by the following:

TIA-568-C.0: Generic Telecommunications Cabling for Customer Premises (replaces applicable TIA 568-B standards)
TIA-568-C.1: Commercial Building Telecommunications Cabling Standard (replaces applicable TIA 568-B standards)
TIA-568-C.2: Telecommunications Cabling, Copper Component and Cabling Specifications (replaces applicable TIA 568-B standards)
TIA-569-B: Commercial Building Standard for Telecommunications Pathways and Spaces
REFERENCES

TIA-606-A: Administration Standard for The Telecommunications Infrastructure of Commercial Buildings


TIA-942: Telecommunications Infrastructure Standard for Data Centers
ANSI-J-STD-607-A: Commercial Building Grounding and Bonding Requirements for Telecommunications
IEEE 802.3: Ethernet-based LANs (multiple standards)
IEEE 1100: Recommended Practice for Powering and Grounding Electronic Equipment
Intertek/ETL: Applicable verifications
ISO 11801: Generic Cabling for Customer Premises (multiple standards)
National Electrical Safety Code (NESC): Published by IEEE
National Electric Code (NEC, NFPA 70): Published by NFPA
Telecommunications Distribution Methods Manual (TDMM): Published by BICSI
Underwriter’s Laboratories (UL): Applicable listings and ratings

Always follow superceding national, state, and local codes and regulations.
51
The following are trademarks of Leviton
Manufacturing Company, Inc:
Acenti®
C1 Ultra™
1
Cone of Silence® ®

Decora®
Excella™

leviton.com/cat6a | 800.722.2082
eXtreme®
QuickPort®
Versi-Duct®
VertiGO®

For Leviton warranty information, please visit © Copyright Leviton Manufacturing Co., Inc. 2010. All rights reserved. Any reproduction is forbidden
Leviton.com/warranties. without express written permission. Information in this guide is provided to assist in understanding
CAT 6A structured cabling systems. All information contained herein is deemed accurate to the best
of the company’s knowledge at time of publication and is subject to change without notice. 52
leviton.com/networksolutions

Leviton Corporate Headquarters Leviton Network Solutions Division Headquarters


201 N Service Road, Melville, NY 11747 USA 2222 - 222nd St. S.E., Bothell, WA 98021-4422 USA
T 800.323.8920 / +1.631.812.6000 F 800.832.9538 T 800.722.2082 / +1.425.486.2222 F 425.487.9486
E info@leviton.com E insidesales@leviton.com

Leviton International Regional Headquarters


Middle East China India / SAARC
(also serving Turkey and Africa) T +852.2774.9876 F +852.2774.1741 T +91.124.4356300
T +971.4.886.4722 F +971.4.886.4723 E infochina@leviton.com E lev_india@leviton.com
E infolme@leviton.com

Latin America Canada


T +52.55.5082.1040 F +52.55.5386.1797 T +1.514.954.1840 F +1.514.954.1853
E lsamarketing@leviton.com E pcservice@leviton.com