Professional Documents
Culture Documents
A318 26 Diff B1 e (Sep2005 CMP) PDF
A318 26 Diff B1 e (Sep2005 CMP) PDF
A318
ATA 26
Smoke Detection
System
Diff to A320
EASA Part 66 B1
A318 26 DIFF B1 E
For training purposes only.
Copyright by Lufthansa Technical Training.
LTT is the owner of all rights to training documents and training
software.
Any use outside the training measures, especially reproduction
and/or copying of training documents and software − also extracts
thereof −in any format all (photocopying, using electronic systems
or with the aid of other methods) is prohibited.
Passing on training material and training software to third parties
for the purpose of reproduction and/or copying is prohibited without
the express written consent of LTT.
Copyright endorsements, trademarks or brands may not be re-
moved.
A tape or video recording of training courses or similar services is
only permissible with the written consent of LTT.
In other respects, legal requirements, especially under copyright
and criminal law, apply.
Lufthansa Technical
Training
Dept HAM US
Lufthansa Base Hamburg
Weg beim Jäger 193
22335 Hamburg
Germany
26
compartment. It gives visual and aural warnings in the cockpit, if smoke or fire
is in the cargo compartment. The system includes:
the smoke detectors,
the smoke annunciator lights and a TEST pushbutton switch,
the Smoke Detection Function of the Cabin Intercommunication Data Sys-
tem (CIDS−SDF)
If smoke in the cargo compartment is detected by the system, indications will
be given on the ECAM upper display unit and via smoke warning lights on the
overhead panel.
A320 A318
ECAM
LAVATORY FWC‘s
smoke
LAVATORY
sensors
SMOKELAV H
smoke
sensors CIDS
CAN BUS
DIR 2
DEU B DIR 1
SDF
SDCU
SDF
MIDDLE CFDIU
LINE
CARGO VENT
For Training Purposes Only
CONTROLER
CARGO
smoke
CAN BUS
sensors
On A320:
On A318:
All smoke detectors are based on the ionization principle. They ionizes the air
The smoke detectors operates on the principle of scattered light. The light
particles that pass between the electrodes. As smoke causes the electrical re-
source, the labyrinth and the photocell are set out in a horizontal plane so that
sistance of the circuit to increase, the voltage in the measurment chamber in-
the photocell cannot receive light. But when there is smoke, the smoke par-
crease to a higher level than the reference chamber. At a set difference level
ticles reflect and scatter a part of the light beam. The photocell receives this
the detector sends a signal to the AEVC.
light and gives an analog signal and set of the alarm.
For Training Purposes Only
A320 A318
FET
For Training Purposes Only
-
DC
+
NEXT
PAGE
SMOKE WARN
< SDCU <GND SCANNING TESTS >
CALLED CIDS - SDF 1 TROUBLE SHOOT GROUND
<DATA REPORT >
SPECIFIC
< RETURN < RETURN < RETURN DATA >
SYSTEM TEST
TEST OK
< SMK DET AVIONICS TEST < SMK DET VCC TEST
< SMK DET FWD LDCC TEST NEXT
For Training Purposes Only
CIDS - SDF
SPECIFIC DATA1 2/2
LAST LEG CLASS 3
<INFORMATION:
REPORT FAULTS >
PREVIOUS LEGS SYSTEM
<REPORT
THE SMOKE WARNINGS TESTS >
REPORT INDICATES SMOKE
<LRU IDENT
DETECTORS WHICH HAVE
LED TO A SMOKESMOKE
WARNINGWARN
<GND SCANNING TESTS >
TROUBLE SHOOT REPORT
GROUND
<<DATA
SMOKE WARNING
REPORT >
SPECIFIC
<RETURN DATA >
INFORMATION:
NO SMOKE WARNING OCCURED
THE SMOKE WARNINGS
REPORT INDICATES SMOKE
DETECTORS WHICH HAVE
LED TO A SMOKE WARNING
For Training Purposes Only
TABLE OF CONTENTS
ATA 26 FIRE PROTECTION . . . . . . . . . . . . . . . . . . . . 1
26−17 LAVATORY SMOKE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CABIN SMOKE DETECTION INDICATION . . . . . . . . . . . . . . . . . . . . . . 4
26−16 SMOKE DETECTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SMOKE DETECTOR PRINCIPLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CFDS MCDU PAGES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
TABLE OF FIGURES
Figure 1 Smoke detection general . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Figure 2 Smoke detection FAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Figure 3 Smoke detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Figure 4 Smoke MCDU menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Figure 5 Smoke bite test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 6 Smoke MCDU warning report . . . . . . . . . . . . . . . . . . . . . . . 13