Professional Documents
Culture Documents
Catalog
Catalog
Information
HAVER Test Sieves are supplied with woven wire cloth, perforated metal plates or electroformed sheets.
... with
Woven Wire Cloth
Test Sieves are supplied with woven
wire cloth with aperture widths from
20 µm to 125 mm.
... with
Perforated
Metal Plates
Square hole plates can
be supplied in hole
widths from 4 mm to
125 mm. They have
proved especially
efficient in the range
from 16 mm hole width
upwards.
Test sieves with square
hole plates are mainly
used for sieving concrete
aggregate materials, road
construction stones,
natural sand, gravel,
brush a.o.
2
Certification and Re- Certification of Test Sieves
DIN EN ISO 9000 ff
Measuring instruments, including
test sieves, have to be serviced,
tested and labelled at regular
intervals. HAVER & BOECKER
offers the opportunity to check test
sieves by a video-analysis-system
at our works laboratory.
As a special Service we can check
your test sieves on-site.
There are two types of tests that
lead to a) a certification or b) to
a calibration. Certification and
calibration differ in the achieched
reliability levels of test results.
The number of measured aperture
sizes for a calibration is three
times higher than for a
certification.
Test results are statistically
interpreted and documented
in a certificate of compliance
with the standard according
to DIN EN 10 204.
3
HAVER Test Sieves
HAVER test sieves excell in accuracy and stability. The optimum
tension of the sieve bottom guaranties a long service life.
Sieve bottoms (woven wire cloth or screens, perforated metal plates
or electroformed sheets) are fixed to the tension ring by soldering,
welding or using adhesives. The tension ring is pressed into the frame
and sticked to it. Sieve bottoms made from woven wire cloth with
20 µm to 45 µm aperture width are usually fixed with their downside
to the tension ring.
The careful fabrication guaranties a good service life with perfect
operation.
To meet the high demands, HAVER & BOECKER carries out regular
receipt and production controlls.
Each test sieve gets a certified compliance with the order 2.1
according to DIN EN 10204 without extra charge.
Upon request and with extra charge an inspection certificate “B”
according to EN 10204 3.1 B can be provided, too. The test record
represents the measuring results of the distribution of apertures in
tabular and graphic form.
4
Test Sieve
with flat frame, especially for ultra-fine
particle-separation.
Sieve bottom permanently soldered.
Stainless Steel:
Diameter D ^ 3”
76.2 = mm
Effective height H 22 mm
Auxiliary Parts
for Test Sieves
Intermediate ring
Sieve frame without base.
5
Test Sieve Shakers and Laboratory Equipment
Test Sieve Shakers are used to separate sieveable products into single fractions. Reproducible test sieve results can
be achieved in the shortest possible time. Hand sieving, which is the basis of the total separation technique, can be
accurately replicated.
HAVER Test Sieve Shakers produce a three-dimensional sieving action. The material is distributed over the whole
sieving surface. For difficult products, sudden interruption of the sieving action using intermittent drives intensifies
the sieving and in many cases reduces the sieving period.
HAVER Test Sieve Shakers have no rotating parts, are extremely durable, maintenance free, very adaptable and have
a low noise level. Due to the use of a special spring system and cast iron parts, the construction is heavy and sturdy.
This avoids unwanted vibrations being transmitted to the stationary parts of the sieve shaker and its stand.
Diameter
203 (8”) • • • • • • • • • •
in mm
250 • •
300 • • • • •
305 (12”) • • • • •
315 • •
350 • •
400 • •
450 (18”) •
Dimension 300 x 300 •
in mm 500 x 500 •
T h ree-dimensional
sieving action • • • • • • • • – –
Two-dimensional
sieving action – – – – – – – – • •
Self readjusting amplitude;
G-Control – • • • – Constant Acceleration /Rotation
Max. amplitude apx./mm –
(with maximum load) 2,2 3 2 2
Intermittend operation • • • • – –
Control programmable • • • • • • • • • •
Control with storing
function – • • • – –
Time switch, minutes 0-59 0-99 0-99 0-99 0-599 0-99 0-99 0-99 0-99 0-99
Continuous operation • • • • – –
All electronic control • • • • – –
Digit display for all
functions • • • • • • • • • •
Max. weight of sieving material –
in kg (with full load) 3 3 6 15 20
D ry sieving • • • • • • • • • •
Wet sieving • • • • • • • • – –
Explosion-proof – – – – • –
Weight, apx. kg (without test sieves) 32 34 38 100 190 82 86 100 25 25
6
Test Sieve Shaker HAVER EML 200 digital plus T
with self-readjusting amplitude; G-Control
– For test sieve diameters:
3” (76 mm), 100 mm, 150 mm,
200 mm, 8” (203 mm)
– Programmable, storing functions
– Three-dimensional sieving action
– All electronic control
– Digital display for all functions
– Max. weight of full sieve tower: 3 kg
TECHNICAL DATA :
Operating voltage: 230 V, 50 or 60 Hz,
110 V, 50 or 60 Hz
Amplitude: self-readjusting, max.
apx. 3 mm
Control: programmable
Weight: apx. 34 kg
The EML 200 standard model can accom-
modate up to 15 half-height test sieves with
200 mm (8", 203 mm) diameter.
Sound absorbing cupboard optional.
7
Test Sieve Shaker HAVER EML 300 digital plus T
with self-readjusting amplitude; G-Control
– For test sieve diameters:
200 mm, 8" (203 mm), 250 mm,
300 mm, 305 mm
– Programmable, storing functions
– Three-dimensional sieving action
– All electronic control
– Digital display for all functions
– Max. weight of full sieve tower: 6 kg
TECHNICAL DATA:
Operation voltage: 230 V, 50 or 60 Hz,
110 V, 50 or 60 Hz
Amplitude: self-readjusting,
max. apx. 2 mm
Control: programmable
Weight: apx. 38 kg
The EML 300 standard model can accom-
modate up to 14 half-height test sieves with
300 mm diameter.
Sound absorbing cupboard optional.
8
Test Sieve Shaker HAVER EML 450 digital plus T
with self-readjusting amplitude; G-Control
– For test sieve diameters:
200 mm, 8” (203 mm), 250 mm,
300 mm, 305 mm, 315 mm, 350 mm,
400 mm, 450 mm
– Programmable, storing functions
– Three-dimensional sieving action
– All electronic control
– Digital indication of all functions
– Max. weight of full sieve tower: 15 kg
TECHNICAL DATA:
Operation voltage: 230 V, 50 or 60 Hz,
110 V, 50 or 60 Hz
Amplitude: self-readjusting,
max. apx. 2 mm
Control: programmable
Weight: apx. 100 kg
The EML 450 can accommodate up to 12
test sieves with 400 mm diameter.
Sound absorbing cupboard optional.
9
Test Sieve Shaker HAVER UWL 400 T
Extremely powerful and silent
– For test sieve diameters:
200 mm, 8” (203 mm),
300 mm, 305 mm, 315 mm, 350 mm,
400 mm
– Three-dimensional sieving action
– Driven by two rotary current unbalanced
motors
– Max. weight of full sieve tower: 20 kg
TECHNICHE DAT E N :
Operation voltage: 230 V, 50 Hz,
others on request
Control: programmable
0-599 minutes or continuous
operation
Weight: apx. 190 kg
HAVER
UWL 400 H
for test sieves with
beechwood frame
300 x 300 mm
or 500 x 500 mm
10
Test Sieve Shakers Tyler Ro-Tap ®
These test sieve shakers reproduce the circular and tapping motion of hand sieving, but with an even mechanical action,
assuring constant and comparable analyses. They are operated by a vertically mounted, totally enclosed 1/4 hp motor.
All machine types are adapted to EC-standards.
TECHNICAL DATA:
Digital time switch: 0-99 minutes
Operating voltage: 230 V, 50 Hz or
110 V, 60 Hz
Revolutions per min.: 278 ± 10
Taps per min.: 150 ± 5
Weight: apx. 82 kg
Dimensions: 710 x 530 x 635 mm
(w x d x h)
11
Test Sieve Cleaners
The cleaner the test sieves, the more exact the sieving results. The HAVER-USC-apparatus and the HAVER-USC-cleaning
fluid have proved most reliable for a deep and thorough cleaning.
12
Sample Splitters and Sample Reducer
Sample splitters and sample reducers are used for dividing sieve material into representative test sieve samples.
HAVER sample splitters divide sieve material into two representative samples by a divider consisting of a number of
alternatively arranged partitions.
The TYLER® sample reducer accomplishes a 16 to 1 reduction by several dividing steps.
13
International Test Sieve Comparison Table 2003 125 –1 mm Internationale Analysensieb-Vergleichstabelle 2003
TEST SIEVES, NOMINAL SIZES OF OPENINGS TABLE 1 SIEBBÖDEN FÜR ANALYSENSIEBE (Prüfsiebe) Maschen- bzw. Lochweiten
1 2 3 4 5 6 7 8 9 10 11
ISO 565 . ISO 3310 DEU FRA GBR NLD USA CAN TYLER®
Table 1, Millimetre sizes
DIN NF N
Principal sizes Supplementary CAN/
Hauptreihe sizes DIN ISO AFNOR BS 410 NEN ASTM E 11 o CGSB- TYLER
Nebenreihen 3310 NF ISO 3310 ISO 3310 2560 ASTM E 323 ● ■ 8.2-M88 Screen Scale
R 20/3 R 20 R 40/3 metric
1 2 3 4 5 6 7 8 9 10 11
ISO 565 . ISO 3310 DEU FRA GBR NLD USA CAN TYLER®
Table 2, Micrometre sizes
DIN NF N
Principal sizes Supplementary CAN/
Hauptreihe sizes DIN ISO AFNOR BS 410 NEN ASTM E 11 o CGSB- TYLER
Nebenreihen 3310 NF ISO 3310 ISO 3310 2560 ASTM E 161 m 8.2-M88 Screen Scale
R 20/3 R 20 R 40/3 metric
15
The use of the latest technology and equipment for quality control guarantee
the highest and constant quality of our woven wire cloth products.
Our methodical quality management system is certified to
DIN EN ISO 9001 : 2000
© HAVER & BOECKER. All rights on any kind of reproduction, in whole or part, reserved.
HAVER CPA Online application for crusher control in the mineral HAVER CPA 4 – Dual Range Quality Management System
processing technology
P 42 E 398 042003 2 Fe Printed in Germany