You are on page 1of 1

How to use Site Master Anritsu

1. Setting Standart GSM > Select standart GSM to use


2. Setting Top and Bottom standart > For SWR click Amplitude Set Buttom : 1.00
Top : 1.50

3. Setting Top and Bottom standart > For DTF click Amplitude Set Buttom : 1.00
Top : 1.10

4. Setting Limit to use > Click Single limit> Edit Limit


Limit For SWR : 1.30
DTF : 1.03
5. Fixed CW must be of
6. Setting D1 and D2 for Bottom and Top position
7. Click Save Set Up if you want to save > Save SetUp> SetUp Name
8. Click Recall SetUp if you want to preview setup which you created
9. Click Save Display if you want to save display/Capture
10. Click Recall Display if you want to preview capture
11. If the calibration Of, you must calibration again;
Start Call> Enter > Calibration. Please wait until calibration finish