You are on page 1of 8
a Loss Prevention System ) Distribution Sey Network | Date: 22.08.2016 ei substations | Loss Prevention ecteeam es SUBSTATIONS - Electricity Distribution Networks Page 1 of 8 pees 1 Bere eee eee eee See eee eee asia Department: Qatar Civil Defence - Loss Prevention Design Department. Sei eof | ‘Type of structure / Loss Prevention Re ments: 7 Rema No sues Eanes: civil Work a | ~ Public Distribution Substation zi Substation Building is 1. MV Panel Room 2No's of FE ( Clean Agent indoor V.C.B- O.C.B + Tx. (Oil Type + Dry Type Located in Open or C02, 10LBS ) | istribution for future use) + F.P_ \Area , it might be far 2. 2- Transformer Room 2No's of FE ( Dry Substations “away or attached with Chemical, 10 LBS) | Neighbours subject to 3. Exit & Safety Signs in Arabic + English Both | site condition Formats | 4, All penetrations will be sealed by Fire | resistance material | 5. Mechanical Sleeves ( Fire Rated, Ga sealed & Water Proof ) to be provided at a | cable entries and exits of wall, — Note thi point 5 is not applicable the area whe cables are entering in substation by sand backfill & underground excavated SUBSTATIONS ~ Electricity Distribution Networks ( Public & Consumers ) | Loss Prevention System Distribution Be | Network Date: 22.08.2016 7 substations | Loss Prevention ee Paianee SUBSTATIONS - Electricity Distribution Networks | Page 2 of 8 Department: Qatar Civil Defence - Loss Prevention Design Department. Serial| Type of = Type of structure / Loss Prevention Requirements Rema Nowe ubctation EAupmentss Civil Work is 1.2. | Outdoor Outdoor Switchgears (R.M.U (Oil or | Substation Building is 1, MV Swt Room 2No's of FE ( Clean Agent or | Distribution |SF6) -F. Swt.-Tx. Swt.) + Tx. (Gi Located in Open C02, 10LBS ) | Substations | Type + Dry Type for future use) + F.P Area , it might be far 2. 2- Transformer Room 2No's of FE ( Dry away or attached with Chemical, 10 LBS) | Neighbours subject to 3. Exit & Safety Signs in Arabic + English Both |site condition Formats | 4. All penetrations will be sealed by Fire resistance material 5. Mechanical Sleeves ( Fire Rated, Gas sealed & Water Proof ) to be provided at all cable entries and exits of wall. Note this | point 5 is not applicable the area where | | cables are entering in substation by sand aa ii _backfill & underground excavated, 1.3. [Package il Type) + Building ( Substations Steel Enclosure Only ) | NA | | | Sanaa | eat ‘SUBSTATIONS ~ Electricity Distribution Networks ( Public & Consumers ) | Loss Prevention System Distribution Network i _ substations Date: 22.08.2016 Loss Prevention Protection as per QCDD Raa SUBSTATIONS - Elect Page 9 0f8 L seseeeunsd Department: Qatar Civil Defence - Loss Prevention Design Department. eee eee Serial Type of \¢ of structure / Loss Prevention Requirements Rema No | Substation Eauemente: aye Work is o ae 14, | Switching Indoor Switchgears (V.C.B-0.C.B) or | Substation Building is 1. MV Swt. Room 2No's of FE ( Clean Agent or Stations Outdoor Switchgears Located in Open CO2, 10LBS ) (R.M.U (Oil or SF6)) Area , it might be far 2. Exit & Safety Signs in Arabic + English Both away or attached with Formats neighbours subject to 3. All penetrations will be sealed by Fire ‘site condition resistance materi 4, Mechanical Sleeves ( Fire Rated, Gas sealed & Water Proof ) to be provided at all cable entries and exits of wall. — Note this | point 4 is not applicable the area where cables are entering in substation by sand i Aare serenade —|— i backfill & underground excavated. _ 15. Remote Ground Mounted Tx. (Oil Type + Dry Substation Building is 1. 2- Transformer Room 1No's of FE ( Dry Stations Type for future use) + F.P Located in Open Chemical, 10 LBS) (GMT) ‘Area, itmight befar | 2. Exit & Safety Signs in Arabic + English Both away or attached with | Formats Neighbours subjectto | 3. Alll penetrations site condition material 4, Mechanical Sleeves ( Fire Rated, Gas sealed &| ‘Water Proof ) to be provided at all cable entries and exits of wall. Note this point 4 is not applicable the area where cables are entering in substation by sand backfill & underground excavated. Saasee eee ooo eeSecnSeee yw SUBSTA icity Distribution Networks ( Public & Consumers ) ——

You might also like