vy
MEDIN EASY BLENDER
INFANT NASAL CPAP SYSTEM
»
Medin Easy blenders are an easy system for giving air and oxygen as a therapy. The
biggest difference compared to the other devices is, that there is no electronical feedback
about parameters like CPAP pressure or breathing frequency.
Easy Blender
The blender as a single unit combined with a serewable
flowmeter (3 Ipm or 15 pm).
The connection to the circuit sa tapped outlet converter.
Compact Gas Mixer for Airand Oxygen
ange step less 21% 10 100% of Oxygen
Alarm system forges supply drop (Air or 02)
Inlet pressure for Ai and Oxygen 3,3 t06 bar
Including 2 m tube Airand 2m tube Oxyzen
Flow meter with range from 010 16 Limi,
50 psi)
For Active CPAP System For Bubble CPAP System
Water Column Bubble Valve
The watercolumn is monitoring the nCPAP 360° Swivel inlet connector
pressure, Rotating pressure adjustment lever.
‘The column inside, displays the level of the
CPAP pressure
Resolution: marks in | em steps.
Automatic over pressure release up from 9 em
1120. —
‘The watercolumn has an integrated clamp
Positive engagement reduces the risk of inadvertent
change,
Settings are clearly indicated
Water level adjustment port allows water to be
added or removed without disconnecting the expi-
ratory circuit,
BD veaijer Qo Miniftow*
‘The Medijet* is an active CPAP generator Miniflow’* is a patient interface for the CPAP mode of
with low noise design and ean be used for ventilators. It can be connected to the inspiration and
drug ination, expiration tubes ad thus tothe venti.
medin
SSE Medical Innovationsmedin easy blender
INFANT NASAL CPAP SYSTEM Accessorie
—~
Heated Humidifier Pole Mount System
Microprocessor Servo Control provides precise Pole with 5 wheels, two with roller stops
and stable humidification in chamber, patient Rail for pole - needed for mounting: flowmeter,
sirway temperature and patient humidity gas blender, sindi, watertrap, manometer, drumo
levels.
Light
3 design by eliminating transformer
Chamber & Circuit with Heating Wire Nasal Mask & Nasal Prong
Circuit with heating wire to use with Medijet and Nasal Mask (1200-04 ; 1200-05 ; 1200-06)
humidification chamber Nasal Prong ( 1200-01 ; 1200-21 ; 1200-0:
1200-22 ; 1200-03)
Bonnet - Single Use
Bonnet for fixation Medijet and Miniflow
7 dierent size (S to XXXL)
(1214-10 ; 1215-10 ; 1216-10 ; 1217-10 ; 1218-10 ;
1219-10 ; 1220-10)
The advantages of the CPAP Generator Medijet :
= No constant flow into patient
- Benveniste prineip with volume reservoir,
ranasal CPAP measurement
- Keep CPAP in the lung stable as much as possible
- Regulation and compensation of leak
- Safety and easy as much as posibbly
- Reduction of work of breathing
= Non aggressive flow application
- Reduction of stomach expansion
= Inerease of FRC and improvement of Compliance
= Low noise level
~ Reduction of RDS
ebliced des, dg bir et
Physica vatve [CPAP Cynder
CPAP memucment
Jevinotor Connstor it
“ sesguen
—, Tt
v
Gestepacomeser| Ping, Safety tole | Nea prog commons
medin
Medical Innovations mmm
‘weewompai.com