Psi Psia Psia (F) AZ-20.R-22 (°F) AZ-20R-22 (°F) AZ-20 R-22 40 108 08 | 0 483 240 | 40 1181 686 39 46115 «10 | 1 496 249 | 41 1203 700 88 121 «14 | 2 509 257 | 42 1227 715 37 128 18 | 3 522 265 | 43 1250 730 86135 = 22 | 4 536 274 | 44 1274 745 35° (4142 26 | 5 550 283 | 45 1298 761 4 4149 31 | 6 563 292 | 46 1322 76 936156 «35 | 7 578 301 | 47 1347 792 2 163 40 | 8 592 310 | 48 1372 808 3117145 | 9 607 319 | 49 1397 824 06178 «49 | 10 622 328 | 50 1422 841 29 186 54 | 11 637 338 | 51 1448 857 28 194 59 | 12 652 348 | 52 1474 874 27 202 64 | 13 668 358 | 53 1501 891 26 211 69 | 14 683 368 | 54 1528 908 2 219 74 | 15 699 378 | 55 1555 926 24 227 80 | 16 715 388 | 56 1582 944 23 236 «485 | 17 732 399 | 57 161.0 961 22 245 91 | 18 749 409 | 58 1638 980 21 254 96 | 19 766 420 | 59 1667 998 20 263 102 | 20 783 431 | 60 1696 1016 49 272 108 | 21 800 442 | 61 1725 1035 18 «282 114 | 22 818 453 | 62 1754 1054 17 292 120 | 23 838 465 | 63 1784 1073 16 301 126 | 24 854 476 | 64 181.5 109.3 45 311 192 | 25 872 488 | 65 1845 1112 14 322 139 | 26 891 500 | 66 1876 1132 13° 332 145 | 27 910 512 | 67 1907 1153 12 342 152 | 28 929 524 | 68 1939 1173 41353 159 | 29 949 537 | 69 197.1 1194 40 364 165 | 30 968 550 | 70 2004 1214 § 375 172 | 31 988 562 | 71 2036 1235 8 386 179 | 32 1009 575 | 72 2070 1257 7 398 187 | 33 1029 588 | 73 2103 1278 6 409 194 | 34 1050 602 | 74 2137 1300 5 421 201 | 35 1071 615 | 75 2171 1922 4 433 209 | 36 1092 629 | 76 2206 1345 3445 217 | 37 1114 643 | 7 224.1 1367 2 457 204 | 38 1136 657 | 7B 2277 1300 A 470 232 | 39 1158 671 | 79 231.3 141.3 Honeywell Genetron Refrigerants P.O. Box 1053 Morristown, New Jersey 07962-1053 For more information call us at 1-800-631-8138 psig psig Psi (CF) AZ20 R22 (°F) AZ-20 R22 ("F) AZ-20 R22 80 234.9 143.6 | 104 334.9 207.7 | 128 4632 200.2 81 238.6 146.0 | 105 339.6 2108 | 129 469.3 293.0 82 242.3 148.4 | 106 344.4 2138 | 130 475.4 2969 83 246.0 1508 | 107 349.3 2169 | 131 481.6 3008 84 249.8 153.2 | 108 354.2 220.0 | 132 487.8 3047 85 253.7 1557 | 109 359.1 2232 | 133 494.1 3087 86 2575 1582 | 110 364.1 2264 | 134 5005 3126 87 261.4 160.7 | 111 369.1 2296 | 135 5069 3167 88 265.4 1632 | 112 374.2 2328 | 196 513.4 320.7 a9 269.4 1658 | 113 379.4 236.1 | 137 520.0 3248 90 273.5 1684 | 114 384.6 239.4 | 198 5266 329.0 91 2778 171.0 | 115 389.9 2428 | 199 5333 393.2 92 281.7 1737 | 116 395.2 246.1 | 140 540.1 397.4 93 2859 1764 | 117 400.5 249.5 | 141 5470 341.6 94 290.1 179.1 | 118 405.9 253.0 | 142 553.9 345.9 95 204.4 181.8 [119 411.4 2565 | 143 5609 3503 96 298.7 1846 | 120 416.9 2600 | 144 567.9 9546 97 303.0 187.4 | 121 422.5 2635 | 145 575.1 359.0 98 3075 190.2 | 122 428.2 267.1 | 146 582.3 363.5 99 311.9 1930 | 123 433.9 270.7 | 147 589.6 368.0 400 3164 1959 | 124 439.6 2743 | 148 5969 3725 101 321.0 1988 [125 445.4 2780 | 149 6044 3771 102 9256 201.8 | 126 451.3 2817 | 150 611.9 381.7 103 330.2 2047 | 127 457.3 285.4 ‘AZ-20(R-410A) pressure Is about 60% (1.6 times) greater than R22. ‘Only use servicing equipment and components designed for AZ-20(F-10A). Recovery cylinder service pressure rating 400 psig 9, DOT 48400 and DOT sco. ~ Manifold sets must be 800 psig high-side and 250 psig low-side wah '550 psig lon-sde retard — Use hoses with 800 psig service pressure rating Use fier driers with service pressure rating of at least 600 psig Do not instal a sucton-ne der nthe gud line ARI color code is rose (PMS color code is 807). Read the label to confirm cyinder contents since ighting conditions may hinder color identification Liquid charge AZ-20. = Use a commercial metering device in the maniold hose. Use an R-410A TKV on indoor sections originally equipped witha TXV; do not use an B-22TXV. Existing capillary tube indoor coils will not operate properly. A liquic-inefiter drier is recommended. Use a polyol ester (POE) lubricant approved by the equipment manufacturer. POE lubricants are not alvays interchangeable, = Minimize exposure of POE lubricant tothe atmosphere; use a pump to transfer lubricant Use a iter drier to remove moisture from POE lubricant in the ‘system — a vacuum pump will not work. Leak detectors should detect HFC (hydrotluorocarbon) refrigerants. = Halide torches will not work effectively. — Instuments designed for CFCs and HCFCs will not have enough sensi for AZ-20. Do not vent AZ-20 to the atmosphere. Never pressurize a micure of alr and refrigerant since It ay become flammable, ‘Always read the Genetron AZ-20 material safety data sheet (MSDS) before Using the material Honeywell Genetror® Reigerants 25.088

You might also like