Specifications of “Network Switches” 1, _L3 SWITCH WS-C3750X-128-S SPECIFICATIONS, + Part Code 2 WS-C3150X-125-S © Quantity required: 2.Nos a) Switch Performance zt Switching Fabric 160 Gops DRAM 512 MB Flash 128MB ‘Total VLANs 1005 VLAN IDs aK Total Switched Virtual Interfaces 1K Vis) Jumbo Frame 9216 Byte Forwarding Rate 35.7 mpps b) Interfaces SEP (mini-GBIC) ports 12.Nos USB Type A 1No Management Mini-USB TypeB 1 No Console Interface 1No RS-232(RI-45 connector) ©) Miscellaneous Authentication Method Kerberos , RADIUS , Secure Shell (SSH) , TACACS* Compliant Standards ASINZ 3548 Class A, ASINZS 60950-1 , CB , CCC , CISPR 22 Class A , CSA C22.2 No. 60950-1 , cUL , EN 60950-1 , ENS5022 Class A , FCC Part 15 A , GOST , IEC 60950-1 , KCC | NOM , RoHS , TUV GS , UL 60950-1 , VCCI Class A ITE Height (Rack Units) 1 @) Networking ‘Compliant Standards IBEE 802.lae , IEEE 802.1D , IEBE 802.1p , IEEE 802.10 , IEEE 802.1s , IEEE 802.1w , IEEE 802.1x , IEEE 802.3 , IEEE 802.3ab , IEEE 802.3ad (LACP) , IEEE 802.3u , IEEE 802.3x, IBEE 802.32, Features Access Control List (ACL) support , ARP support , Auto- negotiation , Auto-uplink (auto MDI/MDI-X), Broadcast Storm Control , Cisco StackWise Technology, DHCP snooping, DHCP support, Dynamic ARP Inspection (DAD, Dynamic IP address assignment, Dynamic Trunking Protocol (DTP) support, High Availability, Hot swap module replacement, IGMP snooping, Jumbo Frames support, Layer 2 switching , Link Aggregation Control Protocol (LACP), MLD snooping, Multicast Storm Control, Per-VLAN Spanning Tree Plus (PVST#), Port Aggregation Protocol (PAP) support, Quality of Service (QoS), Rapid Spanning Tree Protocol (RSTP) support, Remote Switch Port Analyzer (RSPAN), Shaped Ma Ante, oo Manageable Ports Qty Remote Management Protocol Routing Protocol Status Indicators e) Power Device Features Frequency Required Installed Qty. Max Supported Qty Nominal Voltage Power Redundancy Power Redundancy Scheme Type 1) Software (inbuilt) 8) Service & Support Round Robin (SRR), Syslog support, Traffic shaping , Trivial File Transfer Protocol (TFIP) support, ‘Trunkin’, Uni- Directional Link Detection (UDLD), Unicast Storm Control, VLAN support Yes 12 CLI, RMON 1, RMON 2, RMON 3, RMON 9, SNMP 1, ‘SNMP 2, SNMP 2c, SNMP 3, SSH, Telnet, TFTP. HSRP, RIP-1, RIP-2, RIPng, Static TP routing Link activity, Port duplex mode, Port status, Port transmission speed, Power, System Redundant Power System (RPS) connector 50/60 Hz 1 2 AC 120/230 V Optional 141 (with optional power supply) Internal power supply Cisco 10S IP Base Limited lifetime warranty 2. 12 SWITCH 2960CG-8TC-L SPECIFICATIONS. * Part Code 2 WS-C2960CG-8TC-L * Quantity required : 8 Nos a. GENERAL Device Type Enclosure Type Subtype Ports Performance RAM Flash Memory Capacity Jumbo Frame Support Routing Protocol ‘Remote Management Protocol Authentication Method Features Switch - 8 ports - Managed Desktop = 1U Gigabit Ethernet 8 x 10/100/1000 + 2 x shared SEP Forwarding performance (64-byte packet size) :13.2 Mpps Forwarding performance : 10 Gbps 128 MB 64 MB Virtual interfaces (VLANs) : 255 9018 RIP-1, RIP-2 SNMP 1, SNMP 2, RMON 1, RMON 2, RMON 3, RMON 9, Telnet, SNMP 3, SNMP 2c, HTTP, CLI Kerberos, Secure Shell (SSH), RADIUS, TACACS+ DHCP support, auto-negotiation, BOOTP support, ARP support, VLAN support, auto-uplink (auto MDVMDI-X), IGMP ‘snooping, Syslog support, DiffServ support, MA. Broadcast Storm Control, IPV6 support, Multicast Storm Control, Unicast Storm Control, Spanning Tree Protocol (STP) support, DHCP snooping, Dynamic Trunking Protocol (DTP) support, Port Aggregation Protocol (PAgP) support, Trivial File Transfer Protocol (TFTP) support, Access Control List (ACL) support, Quality of Service (QoS), Dynamic ARP Inspection (DAD, STP Root Guard, Uni-Directional Link Detection (UDLD), fanless, DHCP relay, Remote Switch Port Analyzer (RSPAN) IEEE 8023, IEEE 802.3u, IBBE 802.37, IEEE 802.1D, IEEE 802.1Q, IEEE 8023ab, IEEE 8021p, IEEE 802.3x, IEEE 8023ad (LACP), IEEE 802.1w, IEEE 802.1x, IEEE 802.[s, IEEE 802.lac, IEEE 802.lab (LDP) Compliant Standards b. EXPANSION / CONNECTIVITY Interfaces 10 x 10Base-T/100Base-TX/1000Base-T - RJ-45 1x USB - Type A 1 x console - mini-USB Type B - management | x RS-232 - RJ-45 - management 2.x SFP (mini-GBIC) c. POWER Power Device Internal power supply Voltage Required AC 120/230 V ( 50/60 Hz ) 4, 19” Rack mountable fabricated kit is required for these eight switches e. SOFTWARE / SYSTEM REQUIREMENTS, Software Inbulit Cisco 108 LAN Base 3. TRANSCEIVER MODULE, © Partnumber : GLC-LH-SMD= ‘© Description : 1000BASE-LX/LH SFP transceiver module, MME/SMF, 1310nm, DOM © Quantity: 16 Nos ‘The 1000BASE-LX/LH SFP, compatible with the IEEE 802.32 1000BASE-LX standard, operates on standard single-mode fiber-optic link spans of up to 10 km and up to 550 m on any multimode fibers. When used over legacy multimode fiber type, the transmitter should be coupled through a mode conditioning patch cable. 1300-om wavelength, extended operating temperature range and DOM support, dual LC/PC connector. 4, Warranty: one year Onsite comprehensive warranty for SILNo 1, 2, 3 and in case of fault, repair/replacement activity for normal functionality should be completed within next working day. me AE Te ye Pr 5. Vendor eligibility eriteria a) Vendor should be ISO/CMMI certified company. b) Vendor should be a registered partner of CISCO. °) ‘Vendor should have experience in supply, installation & commissioning of CISCO make Switches/Routers with Government departments for last 2 years, 4) Vendor should show proof for above eligibility criteria(a, b,c) “Te Avie Un. SHfeaRTTT/M, ADINARAYANA afte vgn aiftrard-I1/Senior Stores Bi ware, fiesu-IIl [Head CMM-IIL Pe Band ua, tauar-500 058. “For Director, DROL Hycerabas-500 O58. Acceptance Test Procedure(ATP) ; ( ATP for L3 Switch: ‘The following sequence of tests to be carried out and should pass through successfully for all the Switches 4) Scope of Work 8) Offline testing of the Switeh. ») Installation and configuration of Layer 3 Switch. ©) Interconnecting the Switch as per the approved topology. 4) Demonstration of the Network connectivity between the Switches and connected Systems, ii) Sequence of Tests ‘The ATP involves testing of the equipment supplied at various levels, The following sequence of tests will be carried out as a part of ATP and submit the reports accordingly for each of the tests carried out. 1. Switch Level Tests a. Visual Inspection: To ensure all modules are present in proper condition b. Power on Self Test: To check minimal functionality of switch on powering on ¢, Configuration Port Testing: To demonstrate the communication between a terminal and switch. Configuration Testing: To demonstrate the configurability of switch, Memory retention Testing: To demonstrate memory retention functionality of NVRAM. ‘Switch functionality: To test the functionality of the switch between ports. g. Network Connectivity: To check the end to end connectivity of the Network. 2. Network Level Tests: a. Creativity of VLAN: To demonstrate the creation of VLANS, enabling and disabling communication between VLANS. b. Integrated Traffic Testing: To demonstrate the ability of network to cary simultaneously day to day MIS traffic, audio, video and high end graphic images and distribute them to respective destinations. Runtime test: To demonstrate the seamless operation of different operating systems on the network and inter OS communication, d. These Layer3 Ethernet switches should be integrated/configured logically into existing Campus wide Gigabit, fast Ethernet fiber optic LAN. Total network should function normally without any incompatibilities including CDP & VTP protocols, It should be tested for 5 days. Met, Ye ce 3. Network Performance Tests: a, Endurance Test: to demonstrate the network functioning continuously for five days. . Real Time Data Transfer: To demonstrate real time data transfer. ©. QoS (Quality of Service): To demonstrate capability of network to carry various classes of traffic with respective guaranteed levels of quality. This test also proves dynamic allocation of bandwidth. 4, Security Tests: a) VLAN _: Torestrict access from one VLAN to another VLAN. b) Access lists : To restrict access with access lists. ©) Routing: Static routing between the Networks ATP For L2 switch: [All the above sequence of tests are to be carried out and should pass through successfully for all the Switches, except S.No 2d & 4 tests. peony ae - we ha AM, 1. anf Ms, ADINARAVANA ‘afte sian ater -II/Senir Stores Oficer-IT _ saa, aiea-III/Head CMM-IIT ga Rites, ah ome i wer, SeerTe-500 058. for Direcior, DROL Hyderabad-500 058, ist of deliverables ‘SNO | Item Code Ttem Description Quantity 1 WS-C3750X-128-S Catalyst 3750X 12 Port GE SFP IP Base (CAB-3KX-AC-IN ‘AC Power Cord for Catalyst 3K-X (India) S37SXVKST-12258SE___| CAT 3750X JOS Universal with Web base DEV MOR ‘CAB-STACK-S0CM Cisco StackWise 50CM Stacking Cable ‘CAB-SPWR-30CM Catalyst 3750X and 3850 Stack Power Cable 30 CM C3KX-PWR-350WAC Catalyst 3K-X 350W AC Power Suppl 2 Nos ‘CON-SMBS-C375X12S__| SMBS 8XSXNBD Catalyst 3750X 12 Port GE SFP IP Base 2 [WS-C2960CG-8TC-L | Catalyst 2960 Switch 8 GE, 2 x Dual Uplink, LAN Base CAB-IND-10A TOA Power cable for India PWR-CLP Power Retainer Clip For Ciseo 3560-C and 2960-C Compact Switch 8 Nos PEMSE-PRMO-INSRT | Insert, Packout - PI-MSE ‘CON-SMBS-WSC2960G__| SMBS 8X5XNBD Catalyst 2960C Switch 8 GE,1 x Dual 3__| GLC-LH-SMD= 1OO0BASE-LX/LH SFP transceiver module, MMF/SMF, | 16 Nos 1310nm, DOM. 1 Aer a, Xa. STRAIEPTT/M, ADINARAYANA ‘ates sign aiftear-I1 /Senior Stores Officer-It an, #ivwen-IIl /Head CMM-IIL PARRWs, Bons es, Fea-500 058. {or Director, ORDL Hyderabac-500 058.

You might also like