You are on page 1of 1

Praesideo Data Brochure

8.1.1 Interfaces
• 2 x system network connection
• Serial data and power supply interface for call station keypad units.
• Headset socket
Number of connectors :1
Position : Front
Type : 3.5 mm jack
Preferred headset type : Hosiden HBH 0058
Audio : Mono microphone and headset signals

8.1.2 Indications and controls


• The call station basic has three 2-color LEDs which are used for the following
indications:

• LED1 power/error (left LED)


- Green on Power on and no system/call station fault
- Green/yellow off Power not available
- Yellow blinking Fault in the system and power on
- Yellow continuously on Call station error and power on

• LED2 call station status (center LED)


- Green flashing1 Chime on or pre-recorded message playing
- Green on 1 Ready to talk/live announcement
- Green off 1 No call status to display

• LED3 system status (right LED)


- Red An emergency announcement is being made in the system. Normal
announcements can be made to the zones which are not involved
CALL STATIONS

(emergency announcements have priority over other announcements)


- Yellow on Lower-priority announcements are being made or are reserved (to all
or some of the zones which are pre-assigned to the PTT key of the call
station basic and selected zones of the call station keypad unit if fitted)
- Yellow
flashing Announcements with higher or the same priority (not emergency)
are on or reserved (to all or some of the zones which are pre-assigned
to the PTT key of the call station basic and selected zones of the call
station keypad unit if fitted)
- Yellow off
and red off No pre-defined or selected zones are in use or reserved by the system,
8 and no emergency announcement is being made

• Volume control for loudspeaker/headset

1 These indications are active only when the PTT key is pressed. All other indications are shown even in the idle status of the call station