ARI-PREDU®

Sizing diagram for water

Volumetric flow

Example:
Volumetric flow = 24 m3/h
∆p = 4 bar
-----------------------------------------------
24 m3/h x Factor 1,25
= 30 m3/h
choosen DN40

Differential pressure Δp

Edition 12/07 - Data subject to alteration Data sheet 700003 englisch (english)
ARI-PREDU®
Sizing diagram for saturated steam

Steam flow
Downstream pressure
Inlet press.

Example:
Steam flow = 1200 kg/h
Upstream pressure = 10bar / Downstream pressure = 8bar
----------------------------------------------------------------
1200 kg/h x Factor 1,25 = 1500 kg/h choosen DN40

 Edition 12/07 - Data subject to alteration


ARI-PREDU®
Pipe sizing for saturated steam

Example:
Steam upstream pressure = 10 bar(g)
Steam downstream pressure = 4 bar(g)
Steam flow = 5000 kg/h
choosen upstream pipe = DN125
choosen downstream pipe = DN200

Steam flow at 25 m/s (82ft/s) steam velocity


Diameter of the steam pipe

Steam pressure (barg)


Edition 12/07 - Data subject to alteration 
ARI-PREDU®
Flow velocity in pipelines
Volumetric flow qv

Max. Flow velocity:


Liquids 5 m/s (16 ft/s)
Gases and saturated steam 25 m/s (82 ft/s)
Superheated steam 50 m/s (162 ft/s)

Speed