Professional Documents
Culture Documents
Base Plate Design PDF
Base Plate Design PDF
Date:
Sheet No: 1
segzyajibola@yahoo.com Structure: Made by: Segun
UC Base Plate Checked by:
Parameters
Design Axial load, F = 1000 kN Concrete fcu = 40 N/mm2
2
Column Width, B = 254.6 mm Plate design Str.pyp = 270 N/mm
ColumnBreadth, D = 254.1 mm Flange Thickness, tf = 14.2 mm
Web Thickness, tw = 8.6 mm
4.13.2 Effective Area Method:
Bearing strength of concrete, w = 0.6fcu = 24.0 N/mm2
Area required, Areq = Design Axial load
Bearing Strength
= 41667 mm2
Since thickness of the base plate should not be less than that of the flange thicknes
Assumed base plate thickness, tp = 15 mm > 14.2 mm OK
Max. potential effective bearing width, C = tp x (Pyp / 3w)0.5
C = 29.04738 mm
Check for overlap between steel flange
Clear distance between flanges = D ‐ 2tf
= 225.7 mm > 2 x C OK
Effective bearing area, Abe = 4C2 + Col. Perimeter x C + Col. Area 58.09
Col. Perm. = 2[B + (B‐tf)] + 2H = 1498.2 mm
2
Col. Area = B x tf + D x tw = 5800.58 mm
Abe = 52694.36 mm2 > Areq OK
Project: Job Ref:
Date:
Sheet No: 1
segzyajibola@yahoo.com Structure: Made by: Segun
CHS Base Plate Checked by:
Parameters
Design Axial load, F = 1010 kN Concrete fcu = 40 N/mm2
2
Column Diameter, Ø = 219 mm Plate design Str.pyp = 270 N/mm
Column Thickness, tc = 6.3 mm
4.13.2 Effective Area Method:
Bearing strength of concrete, w = 0.6fcu = 24.0 N/mm2
Area required, Areq = Design Axial load
Bearing Strength
= 42083 mm2
Since thickness of the base plate should not be less than that of the flange thicknes
Assumed base plate thickness, tp = 15 mm > 6.3 mm OK
Max. potential effective bearing width, C = tp x (Pyp / 3w)0.5
C = 29.04738 mm
Check for overlap between steel flange
Clear distance between flanges = D ‐ 2t
= 206.4 mm > 2 x C OK
Effective bearing area, Abe = (2C+t)(D‐t)π 58.09
2
Abe = 46845.32 mm > Areq OK