Professional Documents
Culture Documents
ZTE Equipments PDF
ZTE Equipments PDF
Principle
ZTE University
Content
Traditional macro-Base
Station, ATM architecture,
12TRX cabinet ZTE macro-Base Station, IP ZTE SDR, 36TRX cabinet
architecture, 18TRX cabinet
Future Oriented SDR Technology ——
Ensuring Multi-Mode Network Convergence
SDR L
H
G H+
W
Convergence
Software Define Radio
Solution Designed Refarming
Based on unified IP platform New generation multi mode base Convergence, revolution for
with MCPA station traditional base station
CDMA2000 WCDMA
GSM LTE
TD-SCDMA
BBU BBU
Interface Interface
•Different BP boards
SDR RRU Spectrum
Refarming Capable
Multi-band Supported Common
Components Shared
SDR Based Series Base Stations Family
Multi-Mode Supported
Outdoor mini Outdoor micro
GSM/UMTS/HSPA+
ZXSDR BS8908 ZXSDR BS8906
GSM/LTE
UMTS/HSPA+/LTE
RSU40
RSU60E Indoor macro
ZXSDR BS8800 Multi-Band Supported
Radio Unit
GU900M, GL1800M
UL2100M, L2600M
Baseband unit
Long term TCO Saving
RSU40 B8200 RSU40
RSU60E RSU60E 50% HPA technology
Outdoor macro RSU82 RSU82
Embedded indoor macro Smart carrier On/Off
ZXSDR BS8900A
Modularized PM FS High
Fan
Design BP
Reliability
SA CC
GPS system clock & BITS clock & SyncE clock & interface recovery clock
Ethernet switch function, providing switch plan for signaling and media stream
System management
G U
Baseband Processing (BP) Board Introduction
Interface
Description
Name
8 E1/T1 interfaces,
1 RS485interface,
- 1RS232 interface,
6+2 dry contacts ( 6 input interfaces, 2 input & output
interfaces )
Site Alarm Board/Site Alarm Extension Board (Optional)
Fan rate controlling
Site alarm monitoring and interface lightning protection for the rack
Power Module
16 internal interfaces for +12V load power
60W 5 MON
Receiving Sensitivity: 6 AISG
UMTS: -129.2dBm@dual antennas
7 Power
Frequency band:
2100M/AWS
MCPA based, high PA efficiency
Supporting 4 UMTS carriers
Mature commercial application
Interface Index
2*1.25Gbps CPRI optical interfaces Physical Index
2 Antenna interfaces
Physical Index
Volume: 482 mm*88 mm*360 mm (H*W*D)
1 AISG interface Volume: 482 mm*88 mm*360 mm (H*W*D)
Weight: 13 kg
1 Frequency extension interface Weight: 13 kg
GU
Radio Unit — ZXSDR RSU60E
Performance Index
1T2R ANT 1
Capacity:
3 TX RX
6TRXs/4Cs/4TRXs+1C/2TRXs+2Cs RXin
RXout 2
Max TOC: 4 DBG
80W 5 MON
Receiving Sensitivity: 6 AISG
GSM : -113.5dBm@single antenna
7 Power
UMTS: -129.1dBm@dual antennas
Frequency band:
Capacity:
2 TX RX
2*(4TRXs+1C)/2*(2TRXs+2Cs)
ANT 1 3 MON
Max TOC:
4*Antenna interfaces
Physical Index
1 AISG interface Volume: 482 mm*72 mm*360 mm (H*W*D)
Weight: 15 kg
SDR Base Station Introduction
BB
CPRI
FS RRU …
RadioUnit
Radio Unit
E1
SA/ Fiber
STM-1 SE/
NIS CC
GE/FE
Control Signaling
Clock
Data
R8840
+ RRU
R8860E
R8880A
R8882
B8200
BS8700 contains two separate modules: baseband unit and remote radio unit.
U
Remote Radio Unit — ZXSDR R8840
Performance Index
Capacity: Maximum[U]: 4 Carriers
370 mm
Receiving Sensitivity: -129.2dBm@dual antennas
Frequency: 2100M/AWS
Typical Power Consumption (TPC):
UMTS: 100W(S1)/125W(S2)/160W (S3)
Power Supply: -48V DC, 220V/110V AC
Temperature Range: -40℃ to +55℃
Protection Class: IP65
MCPA based, high PA efficiency
Interface: 2*1.25G CPRI optical interfaces
Supporting 4 UMTS carriers
Mature commercial application
Smallest size in the industry
Physical Index
Volume: 370 mm*320 mm*160 mm (H*W*D)
Weight: 16.5 kg
GU
Remote Radio Unit — ZXSDR R8860E
Performance Index
Capacity:
Maximum [G/U]: 6 TRXs/4 Carriers
Maximum [GU] : 4 TRXs+1 Carrier/2 TRXs+2 Carriers
370 mm
Output Power: 80W
Receiving Sensitivity:
GSM: -113.5dBm@single antenna
UMTS: -129.1dBm@dual antennas
Frequency: 850M/EGSM/900M/1800M/1900M
320 mm
TPC:
UMTS: 145W (S2, 900M)
GSM: 160W (S6, 900M)/170W (S6, 1800M)
MCPA based, high PA efficiency GU : 175W (G_S4+U_S1, 900M)
Supporting GU dual mode Power Supply: -48V DC, 220V/110V AC
High output power Temperature Range: -40℃ to +55℃
Protection Class: IP65
Interface: 2*1.25G CPRI optical interfaces
Physical Index
Volume: 370 mm*320 mm*197 mm (H*W*D)
Weight: 20 Kg
U
Remote Radio Unit — ZXSDR R8880A
Performance Index
Capacity: Maximum [U]: 4 Carriers@2*2 MIMO
Output Power: 2*60W
Tx/Rx Tx/Rx Receiving Sensitivity: -129.2dBm@dual antennas
Frequency: 2100M
420 mm
PA PA TPC:
UMTS: 125W(S1@2*10W)/150W(S2@2*20W)
Power Supply: -48V DC, 220V/110V AC
Temperature Range: -40℃ to +55℃
Protection Class: IP65
Interface: 2*2.5G CPRI optical interfaces
MCPA based, high PA efficiency
Supporting 4 UMTS carriers
2T2R, supporting 2*2 MIMO or 2 sectors
High speed CPRI optical interface
Physical Index
Volume: 420 mm*340 mm*140 mm (H*W*D) PA PA PA PA PA PA
Weight: 19 Kg
GU
Remote Radio Unit — ZXSDR R8882
Performance Index
Tx/Rx Rx Rx Tx/Rx Capacity:
Maximum [G/U]: 2*4 TRX/2*2 Carriers
480 mm Maximum [GU] : 2*(4TRX+1Carrier)/2*(2TRX+2 Carriers)
PA PA Output Power: 2*60W
Receiving Sensitivity:
GSM: - 113.5dBm@single antenna
Physical Index
Volume: 480 mm*320 mm*150 mm (H*W*D)
Weight: 20 Kg PA PA PA PA
Diverse Outdoor Distributed BTS Solutions
B8200
Solution I Solution II
RRU RRU
BS8906 BC8910A
Install on
Pole installation top of the tower
Less space required, flexible installation High reliability, suitable for harsh environment
Flexible Networking Capability
STM-1
RNC/BSC
E1/T1/GE/FE
ZTE provides flexible networking for distributed site such as star, chain, loop and hybrid
topology to meet demands from customers.
SDR Base Station Introduction
Expand
600 mm
Radio Unit:
RSU40, RSU60E, RSU82
Cable Chute: Radio unit Auxiliary cabinet
950mm
450mm
600mm
Wall
450mm
ZTE SDR
600mm
marco BTS
600mm
600mm
600mm
Traditional
BTS
0.63 vs 1.08m2
600mm
600mm
40% Space saving
Embedded Indoor Macro BTS — ZXSDR U
BS8800 U120600 mm
Performance Index
Capacity:
1 Radio unit: RSU40
UMTS: 12 CSs (RF capacity limitation)
2 Baseband unit:
Base Band Processing Capability:
1 2 3
B8200 950 mm UL 1920 CEs/DL 1920 CEs (384 CEs*5 BPs)
3 PDM UL 175Mbps/DL 650Mbps
Output Power:
4 Fan Module
60W
4 415mm
Receiving Sensitivity:
-129.2dBm@dual antennas
Supporting UMTS 12CSs Zero footprint TPC:
Lowest power consumption in macro BTSs UMTS: 380W (RSU40, S111)
Power Supply: -48V DC
Interface Index
Iub interface:
8 E1/T1 (Expandable to 16)
1 GE optical or 1*GE/FE electrical Physical Index
2 STM-1
Volume: 620 mm*485 mm*415 mm (H*W*D)
CPRI interface:
Weight: 75 kg
12 CPRI optical interfaces
SDR Base Station Introduction
Output Power:
900M/1800M: 80W/2*80W
Radio Unit: RSU40/
2100M: 60W/ 2*60W
RSU60E/RSU82
Receiving Sensitivity:
GSM: -113.5dBm@single antenna
UMTS: -129.2dBm@dual antennas
Supporting GU dual mode Large capacity TPC :
All in one outdoor site solution Rich interfaces UMTS: 400W (RSU40, S111)
2–8 hours battery backup Smooth evolution GSM: 565W (RSU60E, S666)
2 STM-1
Physical Index
Volume : 1600mm*600mm*600mm (Standard style)
CPRI interface:
Weight: 180 kg (BC8910A+RC8911A, without battery)
12 CPRI optical interfaces
GU
ZXSDR BS8900A Hardware Structure
600 mm Radio Unit:
Top cover 16 mm RSU40, RSU60E, RSU82
Fan & Ventilation
Maximum 6 RSUs
Power system
AC/DC Power System:
B8200 BC8910A Provide -48V DC power supply and distribution
800 mm for BS8900A. It contains monitor unit, rectifier
LPU unit and distribution unit, being totally 5U in
Reserved space 600 mm height.
Heater
Base Band Unit:
B8200
Fan & PDM
RC8911A Transmission Device:
Battery 800 mm 6U reserved space can provide built-in
transmission or microwave devices to save
operators’ investment.
Radio unit
Lightning Protection Unit (LPU):
Bottom base 200 mm Provide lightning protection for signals
Battery Cabinet:
Maximum capacity: 2*150Ah
GU
ZXSDR BS8900A Cabinets Introduction
ZXSDR BS8900A Component Module
600 mm RC8911A: 93 kg
PC8910A: 47 kg
600 mm
Temperature Range:
-40℃ to +55℃
Protection: IP55
SDR Base Station Introduction
SA7
SDR Base Station Introduction
420 mm
Frequency: 900M/1800M
Physical Index
Low power consumption Optimized design Volume: 420 mm*315 mm*100 mm (H*W*D)
Flexible networking Natural cooling Weight: 13 kg
Interface Index
Abis Interface:
4 E1/T1
Tower top
Roof top
1 GE/FE optical or 1*GE/FE electrical
ZTE GU SDR Base Station Products
Summary
Full HSPA capability Low TCO
High processing Fast deployment
throughput
50% HPA
High integration
Large capacity Smooth evolution to
HSPA+ and LTE
80W PA and 4 carriers
supported
Content
UMTS Node B
Remote RRU
Independent
UMTS RAN IP/SDH
Backbone
Traditional Solution
GSM900
UMTS900
Dynamic Power Sharing Enlarging Site Coverage
The sum of each TRX configured maximum output power is bigger than PA maximum output power.
In the area with little traffic, BCCH carrier power configuration can be appropriately added by taking use
of dynamic power, and the remaining power is dynamically real-time shared among all TCH carriers to
enlarge coverage and reduce site quantity.
BCCH 40w
carrier
BCCH 30w User A TCH
5w 30w
carrier carrier A
TCH 30w 30w
TCH 15w 30w carrier B
carrier A
BCCH 40w
TCH 20w 20w carrier
carrier B TCH
User A 15w 30w
carrier A
TCH 20w 30w
carrier B
User B As user moves, each TRX transmission
The sum of each TRX maximum transmission power is no
User B power dynamically adjusts.
bigger than PA maximum output power
All IP-based Network Improving Transmission
Efficiency All IP-based network is the trend for
mobile communication.
TC Pool
SDR Base IP A
Station Flex A
RNC IP Ater
transmission efficiency
IP over FE 23 TRX/2Mbps
All IP baseband Mute frame and IP increases by
processing unit IP over E1 28 TRX/2Mbps
head compression 87%
One Logical Cell with Multi RRU Technology
BBU + RRU remote networking suits coverage scenes such as roads, bridges,
villages along the river and so on.
Cell A
Cell A
Cell A Cell A Cell A
Cell A
One logical Cell with Multi RRU dramatically reduces inter-cell Remote expansion
switch, and improves wireless utilization. Software configuration
Measured UL datarate (Kpbs) of high speed railway scenario Cell A Cell A
110110
100 Multi RRU and AFC disable
73.2 72.8
63.9
Only AFC enable
35.7 •BCCH carrier power unchanged
50 29.8 •Increasing TCH carrier, using
Only Multi RRU enable
12.5 12.8 reserved frequency point to absorb
00 000
Multi RRU and AFC enable traffic
0
•Not changing existing network
0kmph 400kmph 600kmph 800kmph frequency planning
SDR-Based Network Effectively Reducing Energy
Consumption
Highly Efficient PA Improving Overall Antenna-Close Installation Avoiding Feeder
Efficiency Loss
Typical consumption for S444
1250W
PA module adoptes Power consumption RRU
Doherty, DPD and descreased by 42%
multi-carrier PA, 725W RRU RRU is installed close to
increasing overall antenna, saving feeder loss.
efficiency to over For the same coverage
20%. requirement, it reduces RF
output power, hence lowering
Traditional Base Multi-carrier Base BBU power consumption.
Station Station
T T T T T T
R R R R R R
X X X X X X
1 2 3 4 5 6
Multi-carrier PA
Constructing network by using SDR-based Base Station averagely saves single site’s energy by over 40%.
Diverse Networking, tridimensional Coverage
Coverage Challenge in
Dense Urban
One person
limited area