Bruker Optics

VERTEX 70 & 70v FT-IR Spectrometer


The VERTEX 70 series FT-IR spectrometers VERTEX 70: Unmatched FT-IR Performance and Versatility
offer unmatched performance and versatil- The VERTEX 70 is a fully digital FT-IR spectrometer series for demanding
ity for demanding analytical and research R&D applications. Its innovative design results in the highest flexibility and
applications. highest performance. The data acquisition is based on two channel delta-
sigma ADCs with 24-bit dynamic range, which are integrated into the
RockSolidTM interferometer detector preamplifier electronics. This advanced DigiTect technology prevents
external signal disturbance and guarantees the highest signal-to-noise ratio.
2-channel 24-bit dynamic range ADC
Wide Spectral Range
Remotely selectable 5 exit and 2 input
beam ports The VERTEX 70 series can be optionally equipped with optical compo-
nents to cover the spectral range from 15cm-1 (10cm-1 for VERTEX 70v)
Easy beamsplitter change without in the far IR/THz, through the mid and near IR up to the visible/UV
interferometer alignment spectral range at 28,000cm -1. With its pre-aligned optical components
Near IR, visible and far IR/THz spectral and permanently aligned RockSolid interferometer, range change is
easy and maintenance free.
range extensions
Vacuum optics for VERTEX 70v BRAIN: Bruker Artificial Intelligence Network
Automated internal dual sources A network of intelligent functions such as recognition of sampling
accessories and optical components, automatic set up and check of
and dual detectors option
measurement parameters makes FT-IR spectroscopy easy, fast and
Automatic optical components reliable. In addition, the permanent online check of spectrometer com-
recognition ponents keeps fault diagnostics and maintenance simple. A full suite
of software tools ensures this functionality.

F T-IR
think forward
Spectral Range Extension

User-changeable components in RockSolid interferometer used VERTEX 70 and HYPERION 2000 Background and 100%-line (blue
the different compartments are in the VERTEX 70 - 70v FT-IR IR microscope. Up to five beam curves) measured in the visible
easily accessible. spectrometer. exit ports are available. spectral range using 8cm -1
resolution, 30sec measurement
time, 2mm diameter aperture and
tungsten source, visible beam-
Automatic Component Recognition Spectral Resolution splitter and Si-diode detector. By
using an optical filter
The sources, detectors and beam splitters on The standard spectral resolution of better the short wavelength efficiency
the VERTEX 70 - 70v are electronically coded than 0.4cm -1 is suitable for most applications (red curve) can be significantly
to be recognized by the instrument and ap- for solid, liquid and even gaseous samples. improved.
propriate experimental parameters are auto- However, should the needs of your application
matically loaded. In addition, if two conflicting change, the spectrometer can be upgraded to a
components are installed at the same time, the boxcar resolution of 0.16cm -1.
VERTEX 70 series will recognize this and inform
about the mismatch. Versatility
The innovative optics design of the VERTEX 70
Vacuum Optics series results in the most flexible and expand-
With the evacuable optics bench of the able FT-IR spectrometer available. With an eas-
VERTEX 70v vacuum FT-IR spectrometer, ily maintained, sealed and desiccated or evacu-
PEAK sensitivity in the mid-, near and far able (VERTEX 70v) optics bench, the highest
IR/THz regions is obtained without the fear of available sensitivity in the mid-, near- and far
masking very weak spectral features caused IR regions can be obtained on a spectrometer
by water vapor or CO2 absorptions. Outstand- requiring no purge gas or cooling water.
ing results, e.g. in the area of nano-science Different metal oxide polyethyl-
research down to sub-monolayers, can be ob- The VERTEX 70 - 70v offers outstanding flexibil- ene (PE) pellet spectra measured
tained with the new VERTEX 70v vacuum FT-IR ity. Five beam exit ports on the right, front and with far IR optical components
spectrometer. The oil-free dry vacuum pump left side and two beam input ports on the using the standard air cooled
which is included in the instrument delivery pro- right and rear side of the optics bench are source, wideband far IR beam-
vides a vacuum level of less than 0.2hPa (mbar) available. This allows simultaneous connection splitter and room temperature
DLaTGS detector with PE-
within minutes. of, for example, a Hg-arc source at the rear
window at 4 cm -1 spectral
side, the RAM II FT-Raman module at the right,
resolution (spectra are offset for
Plug & Play: Easy Set Up a fibre optics coupling at the right front side and
clarity).
All over the world, no matter where you are, the HYPERION IR microscope at the left side.
plug in the power cord and the Ethernet In addition, a liquid He cooled FIR bolometer
connection, and the VERTEX 70 is ready for detector can be attached at the front-left port.
operation. The Ethernet connection to the
VERTEX 70 also offers the possibility to Bruker Optics
control the spectrometer via your network Technologies used are protected by one or more of is ISO 9001 certified.
or the World Wide Web. the following patents: US 5309217; DE 4212143; US
7034944; DE 10159721; US 5923422; DE 19704598 Laser class 2 product

www.brukeroptics.com Bruker Optics Inc. Bruker Optik GmbH Bruker Optik Asia Pacific Ltd.
Billerica, MA · USA Ettlingen · Germany Hong Kong
Phone +1 (978) 439-9899 Phone +49 (7243) 504-2000 Phone +852 2796-6100
Fax +1 (978) 663-9177 Fax +49 (7243) 504-2050 Fax +852 2796-6109
info@brukeroptics.com info@brukeroptics.de asiapacific@brukeroptics.com.hk

Bruker Optics is continually improving its products and reserves the right to change specifications without notice.
© 2009 Bruker Optics BOPT-090423-2