You are on page 1of 3
raps20%4 SIEMON NEMA Rating and IP Equivalency Chart - Siemon Network Cabling Solutions NEMA Ratings and IP Equivalency Chart NEMA IP iti P Rating Equivalent NPMA Definition Definition 1 P10 Enclosures constructed for indoor use to provide a degree of 1 O=Not protection to personnel against incidental contact with the enclosed Protected Protected equipment and to provide a degree of protection against falling ditt against solid foreign objects of ‘50mm in diameter and greater 2 wil Enelosures constructed for indoor used to provide a degree of 1 1=Protected protection to personnel against incidental contact with the enclosed Protected against vertically equipment, to provide a degree of protection against falling dirt, and against _ falling water to provide a degree of protection against dripping and light solid drops splashing of liquids foreign objects of ‘0mm in diameter and greater 3 ps4 Enclosures constructed for either indoor or outdoor used to provide 5 4=Protected a degree of protection to personnel against incidental contact with Protected against water the enclosed equipment; to proved a degree of protection against. against —_ sprayed fromall falling dir, rain, sleet, snow, and windblown dust; and that will dust - directions - undamaged by extemal formation of ice on the enclosure Limited to Limited to ingress (no ingress harmful permitted deposit) 3R Pa Enclosures constructed for either indoor or outdoor used to provide 1= 4=Protected a degree of protection to personnel against incidental contact with Protected against water the enclosed equipment; to provide a degree of protection against. against —_ sprayed fromall falling dirt, rain, sleet, and snow; and that will be undamaged by vertically directions - external formation of ice on the enclosure falling Limited to water ingress drops permitted, 38 Psa Enclosures consinucted for either indoor or outdoor use to providea 4>Protected degree of protection to personnel against incidental contact with the Protected against water enclosed equipment; to provide a degree of protection against against sprayed fromall falling dit, rain, sleet, snow, and windblown dust; and in which the dust - directions - eaternal mechanism(s) remain operable when ice laden. Limited to Limited to ingress (no ingress harmful permitted deposit) 4 166 Fnelosures constructed foreither indoor or outdoor use to providea 5 6=Protected degree of protection to personnel against incidental contact with the Protected against strong hitp/hwa:sierron.comtsistendards/nema_comparisen asp 18 raps20%4 NEMA Rating and IP Equivalency Chart - Siemon enclosed equipment; to provide a degree of protection against against jets of water from falling dit, rain, sleet, snow, windblown dust, splashing water, and dust - all directions - hose-directed water, and that willbe undamaged by the extemal Limited to Limited to formation of ice on the enclosure ingress (no ingress harmful permitted. deposit) 4X P66 Enclosures constructed for either indoor or outdoor use to provide a $= 6=Protected degree of protection to personnel against incidental contact with the Protected against strong enclosed equipment; to provide a degree of protection against against jets of water from falling dit, rain, skeet, snow, windblown dust, splashing water, hose- dust - all directions - directed water, and corrosion; and that willbe undamaged by thee Limited to Limited to extemal formation of ice on the enclosure ingress (no ingress harmful permitted deposit) 5 IPs2 Enclosures consimucted for indoor use to provide a degree of 5 2=Protected protection to personnel against incidental contact with the enclosed Protected against direct equipment; to provide a degree of protection against falling din; against_—_sprays of water against settling airbome dust, lin, fibers, and flyings; and to provide dust - up to 15° from a degree of protection against dripping and light splashing of Limited to the vertical liquids ingress (no harmful deposit) 6 1P67 Enclosures constructed for ither indoor or outdoor use to provide a 6=Totally 7=Protected degree of protection to personnel against incidental contact with the protected against the enclosed equipment; to provide a degree of protection against against effects of falling dirt; against hose-directed waterand the entry of water during dust temporary occasional temporary submersion at a limited depth; and that will be immersion undamaged by the extemal formation of ice on the enclosure, between 1Sem and Im Duration oftest 30 minutes. ee P67 Enclosures constructed for either indoor or outdoor use to provide a 6=Totally 7=Protected degree of protection to the personnel against incidental contact with protected against the the enclosed equipment; to provide a degree of protection against. against. —_ effects of falling dit; against hose-directed water and the entry of water during dust temporary prolonged submersion at a limited depth; and that will be immersion undamaged by the extemal formation of ice on the enclosure between ISem and Im. Daration oftest 30 minutes. 12and IPS? Enclosures constructed (without knockouts) for indoor use to s= 2=Protected DK provide a degree of protection to personnel against incidental Protected against direct contact with the enclosed equipment; to provide a degree of against sprays of water protection against falling dirt; against circulating dust, lint, fibers, dust - up to 15° from and flying; and against dripping and light splashing of liquids Limited tothe vertical ingress (no harmful deposit) 13 IPs4 Enclosures constructed for indoor use to provide a degree of s= Protected protection to personnel against incidental contact with the enclosed Protected against water equipment; to provide a degree of protection against falling dirt; against_—_sprayed fromall against circulating dust, lint, fibers, and flyings; and against the dust - directions - spraying, splashing, and seepage of water, oil, and noncormsive Limited to Limited to coolants ingress (no ingress harmful permitted. hitp/hwa:sierron.comtsistendards/nema_comparisen asp 28 as20%4 NEMA Rating and IP Equivalency Chart - Siemon deposit) © 1995-2014 Siemon The Siemon Company Siemon Business Park 401 Siemon Company Drive Watertown, CT 06795-0400 USA Phone: (1) 860.945.4200 Fax: (1) 860.945.4225 hitp/hwa:sierron.comtsistendards/nema_comparisen asp

You might also like