You are on page 1of 1

METHODOLOGY

In the beginning the researchers were first asked to prepare a BCA solution this is prepared by mixing
BCA reagent A with BCA reagent B (50:1).

Determination of dynamic
Determination of 𝜆max for standard curve and limit of
each protein assay detectability for each
Protein Assays
protein assay.

The reagent blank, standards


500𝜇𝑔/mL was used for A standard BSA solutions by
and unknowns should be
standard BSA solution. BCA two folding dilution of
measured in the same
method was performed. 500𝜇𝑔/mL BSA was prepared.
experiment.

The absorbances of treated


standard BSA solution from The 𝜆max obtained from the
300nm to 900nm was read. procedure A was used to
For BCA the readings are for perform BCA method.
every 25nm increments.

The absorbance against the


The absorbance against the concentration was plotted.
wavelength was plotted. After After that, the dynamic
that, the 𝜆max for each standard curve and limit
protein were determined. detectability for each protein
assay were determined.