Air system

Filter pressure regulator


Removal and disassembly
Filter maintenance 1. Remove end cap.
2. Remove filter insert from housing and clean.
Cleaner: Soap and water solution, cold cleaner etc.
then blow element from inside using compressed
air.
3. Clean filter regulator housing.

Assembly and installation


1. Renew filter element, seal ring and O-ring if
necessary.
2. Fit end cap, tighten to the correct torque.
3. Check filter regulator function. Unscrew seal plug
(9), attach test connection with gauge.
1. Filter pressure regulator Recommended operating pressure 5.34 to 5.69
2. Filter element bar.
3. Seal ring
4. O-ring Mecman Regulator
5. End cap Filter regulator as used on later models. This
6. Plug component is non serviceable

1. Filter regulator
7. Air supply port
2. Air fitting
8. Outlet port *
3. Air fitting
9. Outlet seal plug *
4. Bracket
10. Capscrew with lockwasher
5. Screw
* Alternative positions