Professional Documents
Culture Documents
Tugs Khusus Kerja Praktik Raw Mill Recovered Done
Tugs Khusus Kerja Praktik Raw Mill Recovered Done
KOMPONEN Mr %MOL
O2 32 1.7
N2 28 55.2
CO2 44 33
SO2 64 0.1
H2O 18 10
TOTAL 100
INPUT
UMPAN RM KERING 623000
DUST LOST SP 23500
GAS PANAS SP 834476
H2O TERKANDUNG 126112
FALSE AIR 176718
TOTAL 1783805.615657
H2O teruapkan
700000 kg/jam
0.05 0.50%
470000 kg/jam 470 ton/jam
23500 kg/jam
KANDUNGAN H2O
% kompossi
PASIR SILIKA PASIR BESI
0.1 4.7
84.5 30.4
8.5 6.2
2.0 43.7
0.5 5.4
4.4 9.6
100 100
kompossi (kg/jam)
PASIR SILIKA PASIR BESI TOTAL
50.1 425.9 287339.2 100 545300 100100
38438.4 2770.0 110530.5 100 545300 100100
3858.4 565.1 25747.4 100 545300 100100
928.2 3975.8 19436.1 100 545300 100100
245.7 493.2 5817.5 100 545300 100100
1979.3 870.0 251129.3 100 545300 100100
45500 9100 700000
m3/jam
K 392 C
atm.m3/kmol.K
atm -76.3 MMWG 10333
kmol/jam
20%
kg/jam
PA PNEGUAPAN
OUTPUT
UMPAN KERING KELUAR 650,118
GAS PANAS 1133688.1
1783805.616
error 0.0
11%
77000 kg/jam
45500 9100
45500 9100
45500 9100
45500 9100
45500 9100
45500 9100
umpan masuk raw mill Kering
INPUT
INPUT
UMPAN RM KERING 863,478
DUST LOST SP 1,823,527
GAS PANAS SP 64,264,024
H2O TERKANDUNG 245,408
FALSE AIR 296,886
TOTAL 67,493,323.38471
H2O teruapkan
false air Panas akibat radiasi /konveksi
RAW MILL
863,478 Kkal/jam
64,264,024 kkal/jam
1,823,527 kkal/jam
245,408 kka/jam
296,886 kkal/jam
OUTPUT
1% UMPAN KERING KELUAR 9,720,557 14%
3% GAS PANAS 17,881,911 26%
95% H2O teruapkan (laten) 39,802,668 59%
0% Radiasi 88,188 0%
0%
67,493,323.38471
0 0.000000
Panas akibat radiasi /konveksi
masuk Cyclone
OUTPUT
Q 9,720,557 kkal/jam
Q 17,881,911 kkal/jam
RUMUS :
Dimana :
s 5.669E-08 W/m2.K4
A 276.57143 m2
e 0.7061812
T1 27 C 300 K
T2 90 C 363 K
0.85985 kkal/W.jam
A= .D.L
p 3.1428571
D 8m
L 11 m
Q 88,188 kkal/jam
DATA Normal Operasi
Gas Masuk RM 883,588.0 kg/jam
False Air Normal 20% 0.2
ASUMSI
Electrical Cost Fan 1459.8 per kWh
Kebutuhan Energi 0.25 kWh/kg
False air (abnormal) 40% 0.4