You are on page 1of 6
Safe - Reliable - Smart SGear 12KV Metal-Clad Switchgear ™ Enhancement Everywhere SRS Power Typical Aplications... Unite the Brand ‘SGear Is indoor type 12KV metalclad switchgear, The design (of SGear is according to AC Metalclad Enclosed Switchgear and Controlgear standard of IEC6227 1-200. ‘With the launching of the SGear, we have given the exclusive privilege to our customers to unite the brand for both Medium Voltage switchgear and Low Votage switchboard. With that, ‘you can enjoy the very same excelent lovel of qualty products and satisfactory service at a very competitive package price We are seriously committed in bringing the same level of competitiveness and flexibilities we have into the Medium Voltage switchgear market. In order to achiave our goals, and objectives, we take full pride in providing the best to our customers through: * Continuous Quest for Excellence in Quality + Implementing efficiency through our Safe Reliable Smart concept + Efficient and speedy response to customers’ requests and ‘+ Fast manufacturing process and ability to meet tight deliver ‘schedule without compromising the quality and standard of the product + More thorough testing and commissioning procedures *+ Better coordination between the Medium Voltage and the Low Vottage systems Key Features * Vacuum interrupters are sealed for Ife and maintenance fee + Costffectve and compact design + Envionmentalienaly + No depostries formed during breaking operation + Long ite of operation + Ample 2p3ce fr cab tormination + Superior interlocking system + Decicated compartments for major apparatus + Ful sogregation of the breaker compartment + Simple nstataton + Motorized mechanism avaiable * Readily extensibie with minimal efforts ard Superior and Reliable Interlocking System Safety Is definitely the prerequisite criterion to be considered when designing SGear. SGear is equipped with superior interlocking systems to prevent unintended operation, thus ‘enhancing is safety measures. ‘+ The circuit breaker must be in the Open postion only then it is allowed to be racked to or racked-out from the ‘connected position ‘+ The circuit breaker can only be closed or open itis in the {otal connected or total cisconnected postion (and no in between) ‘+ The secondary socket isnot allowed to be unplugged if the Ccrcuit breaker isin the connected position ‘+ The earth switch is not allowed to be closed when the circuit breaker isin connected postion ‘© The circuit breaker is not alowed to be rackedin to ‘connected position when the earth switch isin Closed postion ‘+ The cable compartment is not alowed to open ifthe earth ‘switch isin open position Applications Being buit with stingent qualty controls and compliance to international switchgear manufacturing standards, SGear is, suitable across a wide spectrum of applications © Incustriag ~ staal, camant, patrachamical, pape mils, lastc, ol refineries, water treatments, automotive, electrical & electronics, texte, telecommunication and ete + Hospitals + Hypormarkets + Dota Centers + Hotes + High Rise Commercial & Offlce Buleings * Apartments, Condominiums & Residential Universities & Education Institutes SGear 2 Automatic Shutter System ‘SGear is equipped with automatic safety shutter. When the circuit breaker is racked-out from connected position 10 either test or disconnected position, the safety shutter wil automatically close to cover the ive parts. This isto prevent any possible contact of personnel when the circuit breaker is, racked-out, especially during maintenance time. Pressure Release Channel Each compartment ofthe main circuit system is equipped with 2 pressure release channel, During the event of an internal arc-fauit, the pressure release channel flap wil automatically ‘open up, thus guiding the preseurized gas resulted from the fauit tothe rear side direction ‘This mechanizm minimizes damage to the switchgear components and cubice, Earth Switch Grout earthing is achieved through an integral fauit-making earthing switch interacked with the cut breaker and is proven to be safe, simple and reliable, Full Segregation ‘SGear is made of aluminium-zinc coated stee! plate. Its constructed to have a full segregation for the busbar, circuit breaker, low voltage components and cable, thus achieving the requirements of a compartmented switchgear or contro {gear 8 defined in |EC standards. The compartments are ‘also made of steal plate with the intention to minimize the ‘exposure of lve parts when handling the switchgear and to ‘minimize the damage aroa in the event of faut occurs. ‘A Busbar Compartment 8 - Cable Compartment (© Low Voltage Compartment Circuit Breaker Compartment

You might also like